- 05000302/LER-1979-092-03, /03L-0:on 790925,in Mode 1,Halon Recirculation Fans FSF-1 & FSF-2 Failed to Start During Functional Test. Caused by Faulty Design Which Rendered Motor Overloads Inadequate for Fan Operating Characteristics + (ML19259D658)
- ML19259D659 + (ML19259D659)
- ML19259D660 + (ML19259D660)
- ML19259D662 + (ML19259D662)
- ML19259D663 + (ML19259D663)
- ML19259D664 + (ML19259D664)
- ML19259D665 + (ML19259D665)
- ML19259D667 + (ML19259D667)
- ML19259D669 + (ML19259D669)
- ML19259D671 + (ML19259D671)
- ML19259D672 + (ML19259D672)
- ML19259D673 + (ML19259D673)
- ML19259D674 + (ML19259D674)
- 05000219/LER-1979-034, Forwards LER 79-034/01T-0 + (ML19259D675)
- ML19259D676 + (ML19259D676)
- 05000219/LER-1979-034-01, /01T-0:on 791008,both Personnel Access Air Lock 15ors of Reactor Bldg Were Simultaneoulsy Open.Caused by Contractor Personnel Disconnecting Automatic Closing Device on One Door.Device Reconnected + (ML19259D679)
- ML19259D680 + (ML19259D680)
- ML19259D681 + (ML19259D681)
- ML19259D682 + (ML19259D682)
- 05000278/LER-1979-030, Forwards LER 79-030/01T-0 + (ML19259D683)
- ML19259D684 + (ML19259D684)
- 05000293/LER-1979-039, Forwards LER 79-039/01T-0 + (ML19259D685)
- ML19259D686 + (ML19259D686)
- 05000247/LER-1979-022, Forwards LER 79-022/03L-0 + (ML19259D687)
- ML19259D688 + (ML19259D688)
- ML19259D689 + (ML19259D689)
- ML19259D690 + (ML19259D690)
- 05000278/LER-1979-030-01, /01T-0:on 791002,rigid Hanger Failed Due to Contact Between Two of Four Bolts & Base Plate.Caused by Improper Installation.Two shell-type Bolts Were Replaced W/ wedge-type Bolts & Plate Washers Were Installed + (ML19259D691)
- 05000293/LER-1979-039-01, /01T-0:on 791009,re-analysis of safety-related Sys Indicated as-built Configuration Would Not Remain Functional During Sse.Caused by Design Error.Three Supports Have Been Modified & Sys Is Normal + (ML19259D692)
- 05000247/LER-1979-022-03, /03L-0:on 790913,amount of Water in Condensate Storage Tank Was 60,000 Gallons Below Tech Spec Requirement. Caused by Efforts to Reduce High Sodium Concentration in Hot Well + (ML19259D693)
- ML19259D694 + (ML19259D694)
- ML19259D695 + (ML19259D695)
- ML19259D696 + (ML19259D696)
- 05000259/LER-1979-026, Forwards LER 79-026/03L-0 + (ML19259D697)
- ML19259D698 + (ML19259D698)
- ML19259D699 + (ML19259D699)
- 05000346/LER-1979-094, Forwards LER 79-094/03L-0 + (ML19259D700)
- ML19259D701 + (ML19259D701)
- ML19259D702 + (ML19259D702)
- ML19259D704 + (ML19259D704)
- 05000346/LER-1979-094-03, /03L-0:on 790924,boron Injection Flowpath Test Had Not Been Performed to Meet Surveillance Requirement. Caused by Personnel Error.Test Was Successfully Performed on 790925 + (ML19259D705)
- 05000259/LER-1979-026-03, /03L-0:on 790926,recirculation Pumps a & B Tripped During Troubleshooting on Main Sea Level Temp Relays.Caused by Troubleshooting on Wrong Terminal Strip.Strips Relabeled for Better Identification.Pumps Restored to Svc + (ML19259D706)
- ML19260A000 + (ML19260A000)
- ML19260A001 + (ML19260A001)
- ML19260A002 + (ML19260A002)
- ML19260A003 + (ML19260A003)
- ML19260A004 + (ML19260A004)
- ML19260A005 + (ML19260A005)