Text
O J
QUALITY ASSURANCE MANUAL
,m October 3, 1979 g
a 1212 011 7910260 2 3 1
~~-- - -
- "^N-ow.y,,.
g m
(-
""*"YEs.7[sSSI[sUd u
TELEPHON E (6161 Sf 3 1910 g
E.'z a r Q
/
'],
NILES STEELTANK COMPANY QUALITY ASSURANCE PROGRAM 10CFR Part 71 THIS QUALITY ASSURANCE MANUAL SHALL BE USED FOR THE HANDLING, STORAGE AND SHIPPING OF RADIOACTIVE MATERIAL SHIPPING PACKAGES.
THE RADIOACTIVE MATERI AL SHIPPING PACKAGE USED SHALL' BE THE SOURCE CHANGER MODEL 650, DESIGNED, FABRICATED AND FURtilSHED BY THE TECHN ICAL OPERATIONS, INC.,
RADI ATIONS PRODUrTS OlVISION, BURLINGTON, MASSACHUSETTS 01803, WHICH IS AUTHORIZED BY USNRC CERTIFICATE OF
'COMPLIAtlCE NUMBER 9032 REV. 2. (Attached)
Lt
- d. L'ood Radiation Safety Officer NILES STEEL TANK COMPANY 1212 112
.. _ _. =. _ _ _ _
O Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION u2 731 CERTIFICATE OF COMPLIANCE
,g gpq 7, For Radioactive Materials 'acxages 1.fa) Cartificate Numcer 1.(b) Revision No.
1.(c) Package fdentification No.
ow 2
USA /9032/B( )
1.(i) Pages Ns. 1.(O Total No. Pages
- 2. PREAMBLE 2.(a)
This certificate is. sued to satisfy Sections 173.':93a.173.394.173.395. and 173.396 of the Decartment of Transoortation Nazarcous Materiais Regulaticns (49 CFR 170-189 and 14 CFR 103).nd Sections 146-19-104 and 146-19-100 of the Decartment of Transportation Dangerous Cargoes Regulations (46 CFR 146-149). as arnended.
2.(b)
The packagmg and contents cesenbod in item 5 below meets tie safety standards set forth in Subcart C of Title 10. Code of Federal Regulations. Part 71, *'Packagmg of Radioactive Materials for Transport and Tr.
mrtation of Racicas.tive Vatenal Under Cartain Conditions.
2.fc)
This certificate does not relieve the consignor fmm comoliance aith any recuirement of the regulations of the U.S. Ceoartment of Transportation or other acolicaode regulatory agenews, inclucirt "o government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
Prepared by (Name and address):
3.(b)
Title and identsfication of.voort or aoctication:
Technical Operations, Inc.
Technical Operations, Inc. application Radiation Products Division dated August 8, 1979.
l
.$orthwest Industrial Park Burlington, Massachusetts 01803 3.(c) cocwet N 71-9032 4 CONCITIONS
]
This certificate is conditional upon the fulfilling nf the recuirements of Succart O of 10 CFR 71, as acolicable, and the co,ditions speedied in item 5 besow.
- 5. Description of Packaging and Authorized Contents, Model Numoer. Fissile Class. Cther Conditions, and
References:
q (a) Packaging, (1) Model No.: Model 650 (2) Description A steel encased, uranium shielded, Iridium-192 source changer.
Primary components consist Cf an outer steel snell, polyuretnane potting material, aranium shield, Titanium "U" tube, and source holdown assemoly. The source holdown asscriiO.y secures the source assembly in position within the crimoed "U" tuc?
Tamper-proof seals and a pedlock are provided on the packaging. Total weight of the package is approximately 70 pounds.
(3) Drawings The packaging is constructed in accordance with the Technical Oper-ations, Inc. Drawing No. 65002, Rev. A, Sheets 1, 2 and 3 of 3.
l 1212 113
n 'Fage 2 - Certificate No. 9032 - Revision No. 2 - Dockst No.- 71-9032 5.
(b) Contents (1) Type and form of material Iridium-192 as sealed sources which meet the requirements of special form as defined in 171.4(o) of 10 CFR Part 71.
(2) Maximum quantity of material per package 240 Curies 6.
The source shall be secured in the shielded position of the packaging by the source assembly. The source assembly must ce fabricated of materiais capable of resisting a 1475'F fire environment for one-half hour and maintaining their positioning function. The cable of the source assembly must engage the source holdown assembly. The flexible cable of of the source assembly must be of sufficient length and diameter to provide positive positioning of tile source at the crimp of the "U" tube.
7.
The nameplates shall be fabricated of materills capable of resisting the fire "3
test of 10 CFR Part 71 and maintaining their legibility.
~
8.
The package authorized by this certificate is hereby approved for use under the general license. provisions of Paragraph 71.12(b) of 10 CFR Part 71.
3 9.
Expiration date: September 30, 1984.
~
i sEFERENCE I
Technical Operations, Inc. application dated August 8,1979.
FOR THE U.S. NUCLEAR REGULATOPY CCMMISSION b
/
Charles E. MacConald, Chief Transportation Certificz*. ion Branch Office of Nuclear Material Safety and Safeguards
.g Date:
~
1212 014
O>
x-QUALITY ASSURANCE MANUAL Page 1
of 7
1.0 ORGANIZATION 1.1 The final responsibility for the Quality Assurance Program for Part 71 requi rements rests with the Niles Steel Tank Company.
Design and fabrication of the T/0 Model 650 Source Changer shall not be conducted under thic Quality Assurance Program.
1.2 The Radiation Safety Officer is responsible for overall administration of the program, training and certification document. control and audit ing.
1.3 The Radiographers are responsible for handling, storing, shipping, inspection, test, operating 3
status and re cordkeeping.
~
(
i 1212 115
t
. QUALITY ASSURANCE MANUAL Page 2
of 7
2.0 OUALITY ASSURANCE PROCRAM 2.1 Training for all Q. A. Functions, prior to engage-ment in these functions, is required according to written procedures.
Q.A. Program revisions will be made according to written procedures with management approval.
The Q.A. Program will ensure that all defined Q.C. Procedures, Engineering Pro-cedures and specific provisions of the package design approval are satisfied.
The Q.A. Program emphasizes control of the characteristics of the T/0 Model 650 Source Changer, which are critical to safety.
2.2 The Radiation Safety Officer shall assure that all
.~
radioactive material shipping packages are designed I
and manufactured under a Quality Assurance Program,
~
approved by the Nuclear Regulatory Commission for all packages designed or fabricated after 1 January 1979.
t
REFERENCES:
NSTCO Radiography Operations Section 2.0 Training Program Section 3.0 Radiographic Operating Procedures Section 8.0 Source Changer Procedure, inspection and Maintenance Form Cover letter of this Q.A. Manus 1212 016
O QUALITY ASSURANCE MANUAL Page 3
of 7
3.0 DOCUMENT CONTROL 3.1 All documents related to the T/0 Model 650 Source Changer will be controlled througn the use of wri tten procedures.
All docement changes will be performed according to written procedures approved by management.
3.2 The Radiation Safety Officer shall insure that all Q. A. Functions are onducted in 'accordance with the latest applicable c;ianges to these docements.
REFERENCES:
NSTCO Radiography Operations Section 8.0 Source Changer Procedure, inspection and Maintenance Form 1212 'll7
4
~.,
QUALITY ASSURANCE MANUAL Page 4
of 7
- 4. 0 HAN DL IN G, STORAGE AND SH IPP ING 4.1 Written procedures concerning the handling, storage and shipping of the T/0 Model 650 Source Changer will be followed.
Shipments will not be made unless all tests, certifications, acceptances, and final inspections have completed.
Work instructions will be provided for handling, storage and shipping operations.
4.2 Radiography personnel shall perform the critical handling, storage and shipping operations.
REFERENCES:
NSTCO Radiography Operations z
(
Section 8.0 Source Changer Procedure, inspection and Maintenance Form
'T/0 Source Changer Mode' 650 operating instructions 1212
'Ji 8
A QUALITY ASSURANCE MANUAL Page 5
of 7
5.0 INSPECTION, TEST AN') OPERATING STATUS 5.1 Inspection, lest and Operating Status of the T/0 Model 650 Source Changer will be indicated and controlled by written orocedures.
Status will be indicated by log entry.
Status of nonconforming parts or package will be positively maintained by written procedures.
5.2 Radiography personnel shall perform the regu-latory required inspections and tests in accor-dance with written procedures.
The Radiation Safety Officer shall ensure that these functions are performed.
REFERENCES:
'i
'NSTCO Radiography Operations Section 4.0 Internal Inspection and Management Control System Section 5.0 Emergency Procedure Section 8.0 Source Changer Procedure, inspection and Maintenance Form T/0 Source Changer Model 650 Operating instructions 1212 019
QUALITY ASSURANCE MANUAL Page 6
of 7
6.0 CUALITY ASSURAN E RECORDS 6.1 Records o#
ackage approvals, inspect ions, tests, operatins
.ogs, audit resul ts, personnel train ing and qualifications and records of shipments will be maintained.
Descriptions of equipment and written procedures will also be mr:ntained.
6.2 These records will be maintained in accordance with written procedures.
The records will be indenti-fiabic and retrievabic.
A list of these records, with their storage locations, will be naiatained by the Radiation Safety Of ficer.
R EFEP.EN CES:
USNRC Certificate of Compliance 9032 Rest. 2 NSTCO Radiography Operations Section 2.0 Training Program Section 3.0 Radiographic Operating Proccdure
. Section 4.0 in te rn a l Inspection and Management Control System Section 7.0 Inspection and Maintenance Procedures Section 8.0 Source Changer Procedure, inspection and Maintenance Form 1212 920
r
=
QUALITY ASSURANCE MANUAL Page _7_ of 7
7.0 AUDITS 7.1 Established schedules of audits of Quality Assurance Program will be performed using written checklists.
Results of audits will be maintained and reported to management.
Audit reports will be evaluated and deficient areas corrected.
The audits will be dependent on the safety significance of the activity being audited, but each activity will be maintained as part of the quality assurance records.
Members of the audit team shall have no responsibility in the activity being audited.
REFERENCES:
NSTCO Radiography Operations Section 4.0 In te rnal In spection and Man'agement Control System 14364 1212 921
._.