ML19259D671
| ML19259D671 | |
| Person / Time | |
|---|---|
| Site: | 07100001 |
| Issue date: | 09/26/1979 |
| From: | Jerome Murphy ANEFCO, INC. |
| To: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| References | |
| 14268, NUDOCS 7910260231 | |
| Download: ML19259D671 (3) | |
Text
? / -oool
~
~
'., i.
NEiCO ANEFCO INC.*EWAvees M
~
CABLE: ANEFCO WHP TELEX. D 7385
' G'
<V Cocygg59 y USNRC C
Oc.f. o3 ;g79 > j%;
- g
~
90,3
--l September 26, 1979
".. ~
Cj
-%..u C[( 4s
\\
+
+
=
?
S i
b-U.S. Nuclear Regulatory Commission i
'l c
Washington, D.C.
20555 j
Att:
Charles E. MacDonald, Chief 3
Transportation Certification Branch Division of Fuel Cycle and Material W
Safety, NMSS Ref:
Quality Assurance Program 71-001
Dear Mr. MacDonald:
Enclosed are two copies of the answers to the three questions presented in the Request for Additional Information._
It wc'uld appear 'that they do not require specific changes to any see -ion of the manual itself.
Thus, we have answered in letter form.
Very truly yours, ANEFCOINC/
/
',i xI i
'l
[JohnD. Murphy
~ President JDM/er Encl.
1212 322 791.0260 & 3 /
1W463 t
Products Systems and Services "Or er e Nuclear Industry
ANEFCO INC. (71-0001)
QUALITY ASSURANCE MANUAL ANSWERS TO QUESTIONS PRESENTED AUGUST 29, 1979 1.
Qut fications of the QA Manager a.
Educational and professional experience in the engineering
+r science discipline.
b.
Experience and background knowledge in the following:
1.
Non-destructive testing a.
Radiography b.
Ultrasonic testing c.
Leak testing d.
Dye penetrant e.
Other non-destructive technology
. 2.
Materials inventory and logistics control and
, specification a.
Specification preparation b.
Materials testing c.
Logistics managerial control (Records management) 2.
Safety related structures, systems, and compcnents controlled by the QA program.
a.
All materials used in construction of components and/or systems as defined in final drawings and specifications.
b.
Fabrication technology 1.
Materials preparation 2.
Welding 3.
Machining 1212 023 4.
Materials Finishing
~
ANENO Inc. (71-0001) Cuality Assurance Manual Page 2 i
3.
Test programs will be satisfied by assessments of components and systems.
Where applicable, demonstrative prototypes will be used.
This will be in compliance with 71.34; a (1) and a(2) i a
t i
1212 024