ML19259D684

From kanterella
Jump to navigation Jump to search
Forwards LER 79-030/01T-0
Date released: 09/30/2019 Download: ML19259D684


LER 79-030/01T-0:on 791002,rigid Hanger Failed Due to Contact Between Two of Four Bolts & Base Plate.Caused by Improper Installation.Two shell-type Bolts Were Replaced W/ wedge-type Bolts & Plate Washers Were Installed
ML19259D691
Person / Time
Site: Peach Bottom 
Issue date: 10/17/1979
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19259D691 (1)
Forwards LER 79-030/01T-0
ML19259D683
Person / Time
Site: Peach Bottom 
Issue date: 10/17/1979
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19259D683 (2)