- ML18136A334 + (ML18136A334)
- ML18136A335 + (ML18136A335)
- ML18136A336 + (ML18136A336)
- ML18136A337 + (ML18136A337)
- 05000280/LER-1979-040, Forwards LER 79-040/01T-0 + (ML18136A338)
- ML18136A339 + (ML18136A339)
- 05000280/LER-1979-040-01, /01T-0:on 791218,pipe Stress Reanalysis of Show Cause Lines Outside Containment Determined That Feed Header to Nonregenerative & Seal Water Heat Exchangers Overstressed Beyond 50% Ultimate Capacity.Mods Initiated + (ML18136A340)
- ML18136A341 + (ML18136A341)
- ML18136A345 + (ML18136A345)
- ML18136A346 + (ML18136A346)
- ML18136A347 + (ML18136A347)
- ML18136A348 + (ML18136A348)
- ML18136A349 + (ML18136A349)
- ML18136A350 + (ML18136A350)
- 05000280/LER-1979-042, Forwards LER 79-042/01T-0 + (ML18136A351)
- ML18136A352 + (ML18136A352)
- 05000280/LER-1979-042-01, /01T-0:on 791220,as Result of Pipe Stress Reanalysis on Show Cause Lines Outside Containment,Support on Line 10 CC-143-121 Found to Be Overstressed Beyond 50% Ultimate Capacity.Cause Not Stated.Mod Completed + (ML18136A353)
- ML18136A354 + (ML18136A354)
- ML18136A355 + (ML18136A355)
- 05000280/LER-1979-041, Forwards LER 79-041/21X-0 + (ML18136A356)
- ML18136A357 + (ML18136A357)
- 05000280/LER-1979-041-21, /21X-0:on 791219,low Reactor Coolant Flow in Loop a Caused Reactor Trip & Safety Injection.Caused by Ground Fault within Reactor Coolant Pump Motor 1A.Motor Replaced + (ML18136A358)
- 05000280/LER-1979-038, Forwards LER 79-038/03L-0 + (ML18136A359)
- ML18136A360 + (ML18136A360)
- 05000280/LER-1979-038-03, /03L-0:on 791214,two Manual Isolation Valves for Refueling Water Storage Tank Chemical Addition Tank Outlet Valve MOV-CS-102B Found Closed.Caused by Operator Procedural Error.Operators Instructed + (ML18136A361)
- ML18136A362 + (ML18136A362)
- ML18136A363 + (ML18136A363)
- ML18136A365 + (ML18136A365)
- ML18136A366 + (ML18136A366)
- ML18136A367 + (ML18136A367)
- ML18136A368 + (ML18136A368)
- ML18136A369 + (ML18136A369)
- ML18136A370 + (ML18136A370)
- ML18136A374 + (ML18136A374)
- IR 05000280/1979063 + (ML18136A376)
- ML18136A377 + (ML18136A377)
- ML18136A378 + (ML18136A378)
- 05000280/LER-1979-039, Forwards LER 79-039/03L-0 + (ML18136A379)
- ML18136A380 + (ML18136A380)
- 05000280/LER-1979-039-03, /03L-0:on 791214,during Normal Operation,Boric Acid Transfer Pump Strip Heater 2B on Heat Tracing Circuit 26A Failed.Caused by Water Damage to Heat Tracing Circuit. Replaced Strip Heater & Repaired Boric Acid Leak + (ML18136A381)
- ML18136A383 + (ML18136A383)
- ML18136A385 + (ML18136A385)
- ML18136A387 + (ML18136A387)
- ML18136A388 + (ML18136A388)
- IR 05000280/1979060 + (ML18136A389)
- ML18136A390 + (ML18136A390)
- ML18136A391 + (ML18136A391)
- ML18136A392 + (ML18136A392)
- ML18136A393 + (ML18136A393)
- ML18136A394 + (ML18136A394)
- ML18136A395 + (ML18136A395)