- ML18136A178 + (ML18136A178)
- 05000280/LER-1979-029, Forwards LER 79-029/01T-0 + (ML18136A179)
- ML18136A180 + (ML18136A180)
- 05000280/LER-1979-029-01, /01T-0:on 791011,at Cold Shutdown,Min Wall Thickness Violation Discovered in Reducers Mating w/MOV-1842.Caused by Const Deficiency.Reducers Replaced & Verified to Meet Min Wall Thickness Criteria + (ML18136A181)
- 05000280/LER-1979-030, Forwards LER 79-030/01T-0 + (ML18136A182)
- ML18136A183 + (ML18136A183)
- 05000280/LER-1979-030-01, /01T-0:on 791029,radiation Alarm Setpoint Component Cooling Sys Found Greater than Two Times Background.Caused by Improper Setting of Alarm Setpoint.Vent Valve Manually Isolated + (ML18136A184)
- ML18136A187 + (ML18136A187)
- ML18136A188 + (ML18136A188)
- ML18136A189 + (ML18136A189)
- ML18136A190 + (ML18136A190)
- ML18136A191 + (ML18136A191)
- ML18136A192 + (ML18136A192)
- ML18136A195 + (ML18136A195)
- ML18136A197 + (ML18136A197)
- ML18136A198 + (ML18136A198)
- ML18136A199 + (ML18136A199)
- ML18136A204 + (ML18136A204)
- ML18136A205 + (ML18136A205)
- ML18136A207 + (ML18136A207)
- ML18136A208 + (ML18136A208)
- ML18136A210 + (ML18136A210)
- ML18136A211 + (ML18136A211)
- ML18136A212 + (ML18136A212)
- IR 05000280/1979045 + (ML18136A213)
- ML18136A214 + (ML18136A214)
- ML18136A216 + (ML18136A216)
- ML18136A217 + (ML18136A217)
- ML18136A218 + (ML18136A218)
- ML18136A219 + (ML18136A219)
- IR 05000280/1979050 + (ML18136A220)
- ML18136A221 + (ML18136A221)
- ML18136A223 + (ML18136A223)
- ML18136A224 + (ML18136A224)
- ML18136A225 + (ML18136A225)
- ML18136A226 + (ML18136A226)
- ML18136A227 + (ML18136A227)
- ML18136A228 + (ML18136A228)
- ML18136A229 + (ML18136A229)
- ML18136A230 + (ML18136A230)
- ML18136A231 + (ML18136A231)
- 05000280/LER-1979-032, Forwards LER 79-032/01T-0 + (ML18136A232)
- ML18136A233 + (ML18136A233)
- 05000280/LER-1979-032-01, /01T-0:on 791109,notified by Westinghouse of Possible Nonconservative Feature Re Fuel Rod Burst in App K LOCA Analysis.Earlier Clad Burst Caused by Reduction in Heatup Rate.Facility Has Sufficient Margin in Model + (ML18136A234)