ML18136A180

From kanterella
Jump to navigation Jump to search
Forwards LER 79-029/01T-0
Date released: 12/10/2018 Download: ML18136A180


LER 79-029/01T-0:on 791011,at Cold Shutdown,Min Wall Thickness Violation Discovered in Reducers Mating w/MOV-1842.Caused by Const Deficiency.Reducers Replaced & Verified to Meet Min Wall Thickness Criteria
ML18136A181
Person / Time
Site: Surry 
Issue date: 11/06/1979
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18136A181 (2)
Forwards LER 79-029/01T-0
ML18136A179
Person / Time
Site: Surry 
Issue date: 11/06/1979
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18136A179 (1)