- 05000311/LER-1993-007-01, :on 930528,all Four Rods of Control Rod Bank C, Group 1 Unexpectedly Dropped Fully Into Reactor Core.Caused by Degraded Signal from Regulation Board.Card Replaced & Firing Circuit Satisfactorily Tested + (ML18100A436)
- ML18100A437 + (ML18100A437)
- IR 05000272/1993011 + (ML18100A439)
- ML18100A442 + (ML18100A442)
- IR 05000272/1993016 + (ML18100A448)
- ML18100A451 + (ML18100A451)
- IR 05000272/1993017 + (ML18100A453)
- ML18100A454 + (ML18100A454)
- ML18100A455 + (ML18100A455)
- 05000311/LER-1993-008-01, :on 930527,determined That Postulated Single Failure Concern Existed Where Failure of One Rod Control Sys Slave Cycler Decoder Card,In Conjunction W/Rod Motion Command Signal May Cause Rcca Withdrawal + (ML18100A457)
- ML18100A458 + (ML18100A458)
- ML18100A460 + (ML18100A460)
- ML18100A461 + (ML18100A461)
- ML18100A462 + (ML18100A462)
- ML18100A464 + (ML18100A464)
- ML18100A466 + (ML18100A466)
- ML18100A468 + (ML18100A468)
- ML18100A469 + (ML18100A469)
- ML18100A470 + (ML18100A470)
- 05000272/LER-1993-012, :on 930609,vital Bus 1C Sensed Undervoltage Condition,Resulting in Automatic Start & Blackout Loading of DG 1C.Caused by Inattention to Detail on Part of Personnel. Positive Disciplinary Action Completed + (ML18100A471)
- ML18100A472 + (ML18100A472)
- 05000272/LER-1993-011, :on 930608,automatic Reactor Trip from 85% Power Occurred Due to Main Turbine Trip from Low Condenser Vacuum & P-9 Trip Permissive.Caused by Mgt/Qa Deficiency. Circulating Water Intake Structure Dredged + (ML18100A473)
- ML18100A474 + (ML18100A474)
- ML18100A475 + (ML18100A475)
- ML18100A476 + (ML18100A476)
- ML18100A478 + (ML18100A478)
- ML18100A479 + (ML18100A479)
- IR 05000272/1993015 + (ML18100A481)
- ML18100A482 + (ML18100A482)
- ML18100A483 + (ML18100A483)
- ML18100A485 + (ML18100A485)
- ML18100A486 + (ML18100A486)
- ML18100A487 + (ML18100A487)
- ML18100A488 + (ML18100A488)
- ML18100A489 + (ML18100A489)
- ML18100A490 + (ML18100A490)
- ML18100A491 + (ML18100A491)