. DocketNos., 50-272

50-311

50-354

Mr. Steven E. Miltenberger

JUN 2 8 1993

Vice President and Chief Nuclear Officer

Public Service Electric and Gas Company

P. 0. Box 236

Hancocks Bridge, New Jersey 08038

  • Dear Mr. Miltenberger:

SUBJECT:

SALEM UNIT 2 STEAM GENERATOR EDDY CURRENT

EXAMINATION AND E;ROSION CORROSION PROGRAM,

CLOSE OUT OF FINDINGS OF PREVIOUS EROSION/CORROSION

INSPECTION AT SALEM UNIT 1 AND HOPE CREEK

REGION I COMBINED INSPECTION REPORT

  • 50-272/311/93-17 AND 50-354/93-15

This letter refers to the announced inspection intended to promote. public health and safety

conducted by Mr. P. Patnaik of this office, from May 24-28, 1993, at the Salem Nuclear

Generating Station Unit 2 in Hancocks Bridge, New Jersey. Mr. Patnaik discussed the

findings with your staff on May 28, 1993, at the conclusion of the inspection.

The inspection included a review of the eddy current examination program and the upgraded

erosion/corrosion monitoring program implemented during* the seventh refueling outage of

Salem Unit 2. The inspection also focused on your corrective and preventive actions to

Notice of Deviations associated with Salem Unit 1 and Hope Creek Erosion/Corrosion

Monitoring Program.

Within these areas, the inspection consisted of selective examinations of. procedures and

representative records inter\\Tiews with personnel and observations by the inspector. The

Notice of Deviation and unresolved items of previous inspections of Salem Unit 1 and Hope

Creek were closed out based on the results of this inspection. The* new erosion/corrosion

program was found to be satisfactory.*

OFFICIAL RECORD COPY A:SHC9317.INS

'

.

9307060090 930628

L

SDR

ADOCK 05000272

PDR

Mr. Steven E. Miltenberger

2

Your _cooperation with. us in this matter .is appreciated.

  • Sincerely,

Jacque P. Durr, Chief*

Engineering Branch

Division of Reactor Safety

Enclosure: NRC Inspection Report Nos. 50-272/311/93-17 and

50-354/93-15

cc w/encl:

J. J. Hagan, Vice President, Nuclear Operations

C. Schaefer, External Operations - Nuclear, Delmarva Power & Ljght Co;

C. Vondra, General Manager - Salem Operations

F. Thomson, -Manager, Licensing and Regulation

R. Swanson,. General Manager - QA and Nuclear Safety Review

J. Robb, Director, Joint Owner Affairs

A. -Tapert, Program Administrator

R. Fryling, Jr., Esquire

M. Wette:rhahn, Esquire

J. Isabella, D_irector, Generation Projects Department,

Atlantic Electric Company

Consumer Advocate, Office of Consumer Advocate

Tom Dwyer, Public Safety Consultant, Lower Alloways Creek Township

K. Abraham, PAO (2)

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New Jersey

OFFICIAL RECORD COPY A:SHC93l7.INS

, ll !lj " Q 1903

,.. 74* M..,;

W

Mr. Steven E. Miltenberger

bee w/encl:

Region I Docket Room (with concurrences)

bee w/encl: (Via E-Mail)

J. Stone, NRR

S. Dembek, NRR

V. McCree, OEDO

C. Miller, PDI-2, NRR

~:DRS

Patnaik

61

1193

RI:DRS

Gray

f</A(Ec:,

61n1cA

3

RI:DRS

Durr

ytf{/,1 fJJ

6/Z,1/93

OFFICIAL RECORD COPY A:SHC9317.INS