ML18100A483

From kanterella
Jump to navigation Jump to search
Submits Annual Rept Describing Changes to Calculated Peak Cladding Temp,Large Break & Small Break LOCA Analyses. Decrease in Temp for Large Break LOCA Analyses Attributed to Refining Fuel Rod Model to Provide Addl Consistency
ML18100A483
Person / Time
Site: Salem  
Issue date: 07/12/1993
From: Labruna S
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NLR-N93112, NUDOCS 9307200202
Download: ML18100A483 (3)


Text

Public Service Electric and Gas Company I

Stanley LaBruna Public Service Electric and Gas* company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1700 Vice President - Nuclear Engineering JUL 121993 NLR-N93112 U.S. Nuclear Regulatory Commission Attention:

Document Control Desk Washington, DC 20555 Gentlemen:

ANNUAL PEAK FUEL CLAD TEMPERATURE REPORT SALEM GENERATING STATION UNITS 1 & 2 DOCKET NOS. 50-272 AND 50-311 Pursuant to the requirements of 10CFR50.46, Public Service Electric and Gas (PSE&G) hereby submits our annual report describing the changes to the calculated peak cladding temperature (PCT) for Salem Units 1 and 2 Large and Small Break Loss of Coolant Accident (LB LOCA and SB LOCA) analyses.

In the last annual report of July 31, 1992, the PCT values were 2112°F for LB LOCA and 1658°F for SB LOCA.

The revised values for this year are 2109°F for LB LOCA and 1658°F for SB LOCA.

The decrease in PCT for the LB LOCA analyses is attributed to two changes:

1) the fuel rod model was refined to provide more consistent and reliable results for top skewed power shapes, and
2) the vessel material properties used in the code were changed to reflect the actual properties more accurately.

The first change accounted for a PCT penalty of 22°F while the second change provided a benefit of 25°F.

The net change, therefore, was a three degree decrease from 2112°F to 2109°F.

There were no changes made to the SB LOCA calculation since the last report.

Should you have any questions concerning this transmittal, please contact us.

Sincerely, 150(61

Document Control Desk NLR-N93112 2 -

C Mr. T. T. Martin, Administrator - Region I U. s. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. J. C. Stone, Licensing Project Manager U. S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852 Mr. T. P. Johnson (S09)

USNRC Senior Resident Inspector Mr. K. Tosch, Manager, IV NJ Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 JUL 121993

REF,:

NLR-N93112 STATE OF NEW JERSEY SS.

COUNTY OF SALEM S. LaBruna, being duly sworn according to law deposes and says:

I am Vice President - Nuclear Engineering of Public Service Electric and Gas Company, and as such, I find the matters set forth in the above referenced letter, concerning the Salem Unit Nos. 1 and 2 Generating stations, are true to the best of my knowledge, information and belief.

7 Subscribed and Sworn~ before me

. this /:;/. 1;;,_

day of 'X. f.LJ,--

~~~y{),,

0 N t~yPU>i ~of New Jers:y My Commission expires on 1993 KIMBERLY JO BROWN NOTARY PUBLIC OF NEW JERSEY M~ Cummlasien E1pires AprH 21, 1891