Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18096B297 + (ML18096B297)
- ML18096B298 + (ML18096B298)
- IR 05000272/1993003 + (ML18096B300)
- ML18096B301 + (ML18096B301)
- ML18096B302 + (ML18096B302)
- ML18096B303 + (ML18096B303)
- ML18096B305 + (ML18096B305)
- ML18096B306 + (ML18096B306)
- 05000311/LER-1993-003-01, :on 930131,level Indicator of 21 Bast Declared Inoperable Due to False High Level Indications.Caused by Design Construction/Installation.Design Change Will Be Developed to Reduce Bast Boron Concentration + (ML18096B307)
- 05000311/LER-1993-002-01, :on 930128,pumps Tripped on Low Suction Pressure.Caused by Equipment Failure.Loose SGFP Master Controller Test Jack Repaired & Other Jacks in SGFP Speed Control Loop Inspected & Repaired as Required + (ML18096B309)
- ML18096B310 + (ML18096B310)
- ML18096B311 + (ML18096B311)
- ML18096B312 + (ML18096B312)
- ML18096B313 + (ML18096B313)
- ML18096B314 + (ML18096B314)
- ML18096B315 + (ML18096B315)
- ML18096B316 + (ML18096B316)
- ML18096B317 + (ML18096B317)
- ML18096B318 + (ML18096B318)
- ML18096B319 + (ML18096B319)
- ML18096B320 + (ML18096B320)
- ML18096B321 + (ML18096B321)
- ML18096B322 + (ML18096B322)
- ML18096B323 + (ML18096B323)
- ML18096B324 + (ML18096B324)
- ML18096B325 + (ML18096B325)
- 05000311/LER-1993-004, :on 930206,both Main Turbine first-stage Impulse Pressure Indication Channels Indicated False Readings.Caused by Inadequate Sensing Line Protection. Failed Heat Tracing Will Be Repaired + (ML18096B326)
- ML18096B327 + (ML18096B327)
- ND-18-0417, Supplement to Request for License Amendment and Exemption: Changes to Tier 2 Departure Evaluation Process + (ML18096B328)
- ML18096B329 + (ML18096B329)
- ML18096B330 + (ML18096B330)
- ML18096B331 + (ML18096B331)
- IR 05000272/1993005 + (ML18096B333)
- ML18096B334 + (ML18096B334)
- ML18096B335 + (ML18096B335)
- ML18096B336 + (ML18096B336)
- ML18096B337 + (ML18096B337)
- ML18096B339 + (ML18096B339)
- ML18096B340 + (ML18096B340)
- ML18096B341 + (ML18096B341)
- ML18096B342 + (ML18096B342)
- ML18096B343 + (ML18096B343)
- 05000272/LER-1993-004-01, :on 930216,automatic Reactor Trip Occurred Due to Overtemperature Delta Temp Signal.Caused by Equipment Failure.Module Output Gain Selector Switch 1QM411B Cleaned & Exercised & Capacitors Replaced + (ML18096B344)
- ML18096B345 + (ML18096B345)
- IR 05000272/1992016 + (ML18096B346)
- ML18096B347 + (ML18096B347)
- ML18096B348 + (ML18096B348)
- ML18096B349 + (ML18096B349)
- 05000272/LER-1993-005, :on 930218,experienced Reactor Protection Sys Reactor Trip/Turbine Trip Signal,When 12 SG Level Decreased. Caused by Personnel Error.Event Will Be Reviewed for Incorporation in Applicable Training Program + (ML18096B350)
- ML18096B351 + (ML18096B351)
- 05000272/LER-1993-006, :on 930221,station Power Transformers 12 & 22 Deenergized Due to Tripping of Common 13 Kv Ring Bus Section 4 Breakers & 500 Kv Section 1 Breakers.Caused by Inadequate Communication.Caution Tags Hung on Breakers + (ML18096B352)