- 05000272/LER-1989-035, :on 891210,containment Compressed Air Supply Valve Found Untagged in Open Position During Mode Changes. Caused by Personnel Error.Procedure IOP-2 Revised to Include Step to Verify Valve 1SA118 Closed + (ML18095A422)
- ML18095A423 + (ML18095A423)
- 05000272/LER-1990-021-01, :on 900717,discovered That Work Order Not Issued to Perform Revised Procedure 1IC-16.1.008.Caused by Personnel Error.Event Reviewed by Technical Department Mgt Appropriate Personnel + (ML18095A424)
- ML18095A425 + (ML18095A425)
- ML18095A427 + (ML18095A427)
- ML18095A429 + (ML18095A429)
- ML18095A430 + (ML18095A430)
- ML18095A431 + (ML18095A431)
- ML18095A432 + (ML18095A432)
- ML18095A433 + (ML18095A433)
- ML18095A434 + (ML18095A434)
- IR 05000272/1990200 + (ML18095A435)
- ML18095A437 + (ML18095A437)
- ML18095A439 + (ML18095A439)
- 05000272/LER-1990-023-01, :on 900725,discovered That Surveillance of Svc Water Sys Check Valves Not Completed Per Inservice Testing Program Manual Requirements.Caused by Inadequate Administrative Controls.Program Modified + (ML18095A440)
- 05000272/LER-1990-024-01, :on 900728,discovered That Interlock Functions for P-10 & P-12 Permissives Not Fully Tested Per Tech Spec Surveillance 4.3.1.1.2.Caused by Inadequate Administrative Controls.Procedures Revised to Address Testing + (ML18095A441)
- ML18095A442 + (ML18095A442)
- ML18095A443 + (ML18095A443)
- ML18095A444 + (ML18095A444)
- ML18095A445 + (ML18095A445)
- ML18095A447 + (ML18095A447)
- ML18095A448 + (ML18095A448)
- IR 05000272/1990021 + (ML18095A450)
- 05000272/LER-1990-025-01, :on 900806,control Room Air Intake Radiation Sys Monitor Alarm Circuitry Spiked High Resulting in Automatic Switching of Ventilation to Accident Mode of Operation.Addl Spikes Occurred on 900807 & 08 + (ML18095A452)
- ML18095A453 + (ML18095A453)
- ML18095A454 + (ML18095A454)
- ML18095A455 + (ML18095A455)
- 05000311/LER-1990-031, :on 900802,valve 21MS18 Main Steam Line Isolation Control Circuit Failed to Close.Caused by Failure to Wire Control Circuitry Per design.Seal-in Contacts Removed from Circuit & Circuit Adjusted + (ML18095A457)
- ML18095A458 + (ML18095A458)
- ML18095A459 + (ML18095A459)
- ML18095A460 + (ML18095A460)
- ML18095A461 + (ML18095A461)
- ML18095A462 + (ML18095A462)
- ML18095A463 + (ML18095A463)
- ML18095A464 + (ML18095A464)
- ML18095A465 + (ML18095A465)
- IR 05000272/1990019 + (ML18095A467)
- IR 05000272/1990014 + (ML18095A468)
- ML18095A469 + (ML18095A469)
- 05000272/LER-1990-027-01, :on 900812,main Steamline Isolation Actuation Occurred.Caused by Possible Equipment/Design Concerns. Design Mods to Correct Main Steamline Flow Instrumenation Concerns Under Development + (ML18095A470)
- 05000272/LER-1990-026-01, :Several Occurrences of ASME Code 3 Piping Leakage Occurred Starting on 900611.Caused by Equipment Failure.All Affected Components Repaired Per ASME Code + (ML18095A471)
- 05000311/LER-1990-033, :on 900809,isolation Signals Received from Containment purge/pressure-vacuum Relief Sys & on 900824, Second ESF Signal Occurred.Caused by Design/Equipment. Channel 2R11A Repaired + (ML18095A473)
- 05000311/LER-1990-032, :on 900809,inservice Testing Program Discovered Not in Compliance.Caused by Inadequate Administrative Control.Review of Administrative Controls for Compliance W/Surveillance Frequency Changes Initiated + (ML18095A474)
- ML18095A475 + (ML18095A475)
- ML18095A476 + (ML18095A476)
- 05000272/LER-1990-029-01, :on 900817,reactor Trip from 25% Power Occurred Due to Steam Generator lo-lo Level.Caused by Equipment Failure.Circuit Breaker Encl Positive Interlock Assembly Deficiencies Corrected + (ML18095A477)
- 05000311/LER-1990-034, :on 900819,partial Main Steamline Isolation Occurred Due to Procedural Inadequacy.Applicable Procedures Revised by Adding Precautionary Statement.Event Reviewed by Operations Mgt + (ML18095A479)
- 05000272/LER-1990-028-01, :on 900814,Tech Spec 3.0.3 Entered Due to More than One Arpi Per Bank Inoperable.Caused by Sys Design.Sys Presently Under Consideration for Upgrade to Eliminate Temp Susceptibility of Coils + (ML18095A481)
- ML18095A482 + (ML18095A482)
- ML18095A486 + (ML18095A486)
- 05000311/LER-1990-035, :on 900824,determined That Tech Spec Table 4.3-1 Requirements Not Fully Performed at Required Frequency.Caused by Personnel Error.Procedures Reviewed & Technically Verified + (ML18095A487)