ML18095A482
| ML18095A482 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 09/05/1990 |
| From: | Blough A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Miltenberger S Public Service Enterprise Group |
| Shared Package | |
| ML18095A484 | List: |
| References | |
| NUDOCS 9009250147 | |
| Download: ML18095A482 (2) | |
See also: IR 05000272/1990020
Text
{{#Wiki_filter:I - t
Docket Nos. 50-272 50-311 SEP 5 1990 Public Service Electric and Gas Company ATTN: Mr. S. E. Miltenberger Vice President and Chief Nuclear Officer P.O. Box 236 Hancocks Bridge, New Jersey 08038 Gentlemen: Subject: Inspection No. 50-272/90-20; 311/90-20 This letter transmits the findings of the inspection conducted by Messrs. T. P. Johnson, S. M. Pindale, S. T. Barr, and H. I. Gregg from June 28 - August 15, 1990 at the Salem Nuclear Generating Station. The findings of the inspection were discussed with Mr. V. J. Polizzi of your staff. The inspection was conducted to review the circumstances surrounding the mis- operation of two out of four main steam isolation valves .(MSIVs) following a Unit 2 automatic reactor trip on June 28, 1990. Subsequent review identified an apparent main steam line isolation circuit design deficiency which caused the failure of the two MSIVs to fully close when manually actuated. Additional MSIV problems related to the valves* ability to fully close under certain postulated conditions were identified and resolved. No reply to this letter is required. Your cooperation with us is appreciated. A. Randolph Blough, Chief Projects Branch No. 2 Division of Reactor Projects Enclosure:* NRC Combined Inspection Report No. 50-272/90-20; 50-311/90-20 (l .... - ...... , \\J ' \\} .i. . OFFICIAL RECORD COPY 9009250147 9009<.)!_~ PDR Ar:11-1r..:-*L:" Q -
- r*. 05000272
F'DC CIR SALEM 90-20/20 - 0001.0.0 08/27/90 /~6( I/ /
- -
Public Service Electric and Gas Company cc w/encl: 2 SEP 5 1990 J. Urban, General Manager, Fuels Department, Delmarva Power & Light Co. S. LaBruna, Vice President - Nuclear Operations L. K. Miller, General Manager - Salem Operations B. A. Preston, Manager, Licensing and Regulation General Manager, Nuclear Safety Review M. J. Wetterhahn, Esquire R: Fryling, Jr., Esquire Scott B. Ungerer, Manager, Joint Generation Projects Department, Atlantic Electric Company D. Wersan, Assistant Consumer Advocate, Office of Consumer Advocate J. T. Robb, Director, Joint Owner Affairs, Philadelphia Electric Co. J. Lipot, State of New Jersey J. H. Walter, Chief Engineer, Public Service Commission of Maryland A. C. Tapert, Program Administrator, Office of Radiation Control, Division of Public Health for the State of Delaware Lower Alloways Creek Township Public Document Room (PDR) .Local Public Document Room (LPDR) Nuclear Safety Information Center (NSIC) NRC Resident Inspector State of New Jersey bee w/encl: Region I Docket Room (with concurrences) Management Assistant, DRMA (w/o encl) DRP Section Chief S. Barber, Senior Resident Inspector, Susquehanna R. Bellamy, DRSS TI Coordinator, DRP J. Stone, NRR Project Manager R. J. Kiessel, NRR J. Caldwell, NRR H. Gregg, DRS L. Cheung, DRS M. Chiramal, DRS bee w/Report Cover Sheet only: C. Hehl, DRP J. Wiggins, DRP W. Hodges, DRS J. Durr, DRS R. Gallo, DRS M. Knapp, DRSS W. Butler, NRR 'fl-{ r:wtp: RI --1_ DRP: RI ~r ~ 1 (jT~ P. Johnson ~P.~. ~wetland ~A. R. Blough 8121190 r <i 3, 1'1 u ci ; s /'n:: OF ICIAL RECORD COPY CIR SALEM 90-20/20 - 0002.0.0 08/27/90 }}