UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 August' 28, 1990 Docket No. 50-272 Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric & Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038
Dear Mr. Miltenberger:
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION, STEAM GENERATOR SURVEILLANCE REQUIREMENTS, SALEM GENERATING STATION, UNIT NO. 1 (TAC NO. 75172)
In reviewing your amendment request, dated September 13, 1989 (LCR 88-09),
- that proposed changes to the steam generator surveillance Technical Specifications (TSs) for Salem 1 and 2, the staff has determined that a.dditional i.nformation is needed to complete the review.
One of the proposed changes to the Salem 1 TSs was to change the definition of "Defect" by deleting the statement "Any tube which does not permit the passage of the eddy current inspection probe shall be deemed a defective tube." This particular requirement was included in the TSs, to require *plugging of tubes that had been "dented" to the point that the probe would not pass.
In order to complete our review, the following additional information is requested:
- 1.. Has 100% of tubes been examined and the amount of "denting" measured?
- 2.
Your basis for the assumption that tube "denting" has been corrected. Please include:
- a.
Historic data on tubes that would not pass the eddy current probe.
- b.
Diameter of probe(s).used.
- c.
Profilometer data for tubes.
- 3.
What action does PSE&G propose to take on steam generator tubes that will not allow the passage of the eddy current probe?
(
~c10*=**-, *t-~--:--:~--
F-.[i-
'-'*-'* t..l1C.HJ 900*="-:"=*~
I IR AY -*L...... -.;,;;;*..:..*-*
p
- '-' '--*r~. 050002'72 PDC i
Mr. Steven August 28, 1990 In order for the staff to complete its review of the amendment, a response is requested within 90 days of receipt of this letter. The reporting and/or recordkeeping requirements of this letter affect fewer that ten respondents; therefore, OMB clearance is not required under P.L.96-511.
cc: See next page DISTRIBUTION Docket File NRC and Local PDR
.PDI-2 Reading SVarga BBoger M0 1Brien JS tone MThadani OGC.
EJordan ACRS (10)
RBlough PSwetland CCheng DOCUM T NA~ME* TAC NO. 75172 A
PDI-2/PM ~DI-2/D
, n JStone:ag WButler 8'0 90 08~1 /90 08/)J/90 Sincerely, Isl James C. Stone, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
~-r-,~
, EMEB s;;_c..V CCheng 08/J-7/90
J_.'...
I Mr. Steven August 28, 1990 In order for the staff to complete its review of the amendment, a response is requested within 90 days of receipt of this letter. The reporting and/or recordkeeping requirements of this letter affect fewer that ten respondents; therefore, OMB clearance is not required under P.L.96-511.
cc:
See next page Sincerely,
~
~one!!::::nager Project Directorate 1-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
1 Mr. Steven August 28, 1990 In order for the staff to complete its review of the amendment, a response is requested within 90 days of receipt of this letter. The reporting and/or recordkeeping requirements of this letter affect fewer that ten respondents; therefore, OMB clearance is not required under P.L.96-511.
cc:
See next page DISTRIBUTION Docket File NRC and Local PDR PDI-2 Reading SVarga BBoger M0 1Brien JS tone MThadani OGC EJordan ACRS (10)
RBlough PSwet1and CCheng DOCUM T NA~ME* TAC NO. 75172 A
PDI-2/PM ~DI-2/D
, n JStone:ag WButler 8'0 90 08~1 /90 08/l}/90 Sincerely, Isl James C. Stone, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
~,e_~
EMEB C...V CCheng 08/J-7/90
Mr. Steven E. Miltenberger Public Service Electric & Gas Company cc:
Mark J. Wetterhahn, Esquire Bishop, Cook, Purcell & Reynolds 1400 L Street NW Washington, DC 20005-3502 Richard Fryling, Jr., Esquire Law Department - Tower SE 80 Park Place Newark, NJ 07101 Mr. L. K. Miller General Manager - Salem Operations Salem Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. S. LaBruna Vice President - Nuclear Operations Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Mr. Thomas P. Johnson, Senior Resident Inspector Salem Generating Station U.S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection CN 415 Trenton, NJ 08625-0415 Maryland People's Counsel American Building, 9th Floor 231 East Baltimore Street Baltimore, Maryland 21202 Mr. J. T. Robb, Director Joint Owners Affairs Philadelphia Electric Company 955 Chesterbrook Blvd., SlA-13 Wayne, PA 19087 Salem Nuclear Generating Station Richard B. McGlynn, Commission Department of Public Utilities State of New Jersey 101 Commerce Street Newark, NJ 07102 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. ~ox 157 Hancocks Bridge, NJ 08038 Mr. Bruce A. Preston, Manager Licensing and Regulation Nuclear Department P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Mr. Scott B. Ungerer MGR. - Joint Generation Projects Atlantic Electric Company P.O. Box 1500 1199 Black Horse Pike Pleasantville, NJ 08232 Mr. Jack Urban General Manager, Fuels Department Delmarva Power & Light Company
- 800 King Street Wilmington, DE 19899 Public Service Commission of Maryland Engineering Division ATTN:
Chief Engineer 231 E. Baltimore Street Baltimore, MD 21202-3486