- ML18022A436 + (ML18022A436)
- ML18022A437 + (ML18022A437)
- ML18022A438 + (ML18022A438)
- ML18022A439 + (ML18022A439)
- ML18022A440 + (ML18022A440)
- ML18022A443 + (ML18022A443)
- ML18022A444 + (ML18022A444)
- ML18022A445 + (ML18022A445)
- ML18022A452 + (ML18022A452)
- ML18022A453 + (ML18022A453)
- ML18022A457 + (ML18022A457)
- ML18022A459 + (ML18022A459)
- ML18022A461 + (ML18022A461)
- ML18022A464 + (ML18022A464)
- ML18022A465 + (ML18022A465)
- ML18022A466 + (ML18022A466)
- ML18022A467 + (ML18022A467)
- ML18022A468 + (ML18022A468)
- ML18022A469 + (ML18022A469)
- ML18022A470 + (ML18022A470)
- ML18022A471 + (ML18022A471)
- RAIO-0118-58271, LLC Response to NRC Request for Additional Information No. 302 (Erai No. 9276) on the NuScale Design Certification Application + (ML18022A473)
- ML18022A474 + (ML18022A474)
- ML18022A475 + (ML18022A475)
- ML18022A476 + (ML18022A476)
- ML18022A477 + (ML18022A477)
- ML18022A479 + (ML18022A479)
- ML18022A480 + (ML18022A480)
- ML18022A481 + (ML18022A481)
- ML18022A482 + (ML18022A482)
- ML18022A487 + (ML18022A487)
- ML18022A488 + (ML18022A488)
- ML18022A492 + (ML18022A492)
- ML18022A499 + (ML18022A499)
- ML18022A501 + (ML18022A501)
- ML18022A502 + (ML18022A502)
- 05000400/LER-1987-018, :on 870403,manual Reactor Trip Initiated Due to Loss of Both Main Feedwater Pumps.Caused by Inadvertent Short of Test Leads in Process Instrumentation Cabinet & Incorrect Setpoint.Undocumented Leads Removed + (ML18022A504)
- ML18022A508 + (ML18022A508)
- ML18022A510 + (ML18022A510)
- 05000400/LER-1987-021, :on 870414,circulating Water Sys Flow to Main Condenser Restricted,Resulting in High Condensate Temps,Trip of Both Feedwater Trains & Manual Trip of Turbine & Reactor. Caused by Debris on Pump Suction Screens + (ML18022A511)
- 05000400/LER-1987-019, :on 870412,manual Plant Trip Initiated Due to Loss of Feedwater Trains & Decreasing Steam Generator Levels.Caused by Condensate Pump High Temp Trip.Pressure & Steam Generator Levels Restored + (ML18022A512)
- 05000400/LER-1987-022, :on 870402,Tech Spec 3.3.3.10 Discovered Violated Due to Flow Estimates Taken at Beginning & End of Radioactive Releases on 870327,28 & 0401 Instead of Every 4 H.Caused by Inoperable Flow Rate Instrument + (ML18022A513)
- RAIO-0118-58190, LLC Supplemental Response to NRC Request for Additional Information No. 58 (Erai No. 8835) on the NuScale Design Certification Application + (ML18022A514)
- ML18022A515 + (ML18022A515)
- ML18022A517 + (ML18022A517)
- ML18022A518 + (ML18022A518)
- ML18022A521 + (ML18022A521)
- ML18022A522 + (ML18022A522)
- ML18022A523 + (ML18022A523)
- ML18022A524 + (ML18022A524)
- 05000400/LER-1987-020, :on 870413,reactor Trip Setpoints on All Three Overtemp Delta Temp (Odt) Bistables Incorrectly Set.Caused by Apparent Design Oversight in Odt Circuit Design & Vendor Testing Methodology.Test Procedures Revised + (ML18022A525)