- ML17326B563 + (ML17326B563)
- 05000316/LER-1989-004, :on 890210,leakage Through Pressurizer Safety Valves (EIIS/AB-RV) Detected Via Temp & Acoustic Monitor Indications.Caused Attributed to Setpoint Drift.Valve Inspected & Disc & Seat Polished & Lapped + (ML17326B564)
- ML17326B566 + (ML17326B566)
- ML17326B568 + (ML17326B568)
- IR 05000315/1989007 + (ML17326B569)
- ML17326B570 + (ML17326B570)
- ML17326B572 + (ML17326B572)
- 05000316/LER-1989-007, :on 890310,reactor Trip Signal Received Due to lo-lo Steam Generator Level.Caused by Failure of Personnel to Adequately Anticipate Required Auxiliary Feedwater Flowrate.Personnel Involved Counseled + (ML17326B573)
- ML17326B575 + (ML17326B575)
- IR 05000315/1989013 + (ML17326B577)
- ML17326B579 + (ML17326B579)
- ML17326B580 + (ML17326B580)
- ML17326B581 + (ML17326B581)
- ML17326B582 + (ML17326B582)
- ML17326B583 + (ML17326B583)
- ML17326B584 + (ML17326B584)
- ML17326B586 + (ML17326B586)
- IR 05000315/1989009 + (ML17326B587)
- PNO-III-89-026, on 890409 & 10,circuit Breakers on Cd Diesel Generator Invertor Verified to Be in Closed Position. Licensee Investigation Concluded That Neither Mechanical Failure or Electrical Fluctuations Caused Breakers to Open + (ML17326B588)
- ML17326B589 + (ML17326B589)
- 05000316/LER-1989-002, :on 890116,seismic Restraint,Located on 24-inch ECCS Suction Line,Noted to Have Significant Deformation. Probably Caused by Removal & Reinstallation of Piping During Startup.Mod Initiated to Repair Restraint + (ML17326B590)
- 05000315/LER-1988-014, Withdraws LER 88-014-00 Re Incorrectly Routed Emergency Svc Water Cables Associated W/Pump Discharge Valve.Cables Have Been or Will Be Rerouted Per 10CFR50,App R + (ML17326B591)
- ML17326B593 + (ML17326B593)
- ML17326B594 + (ML17326B594)
- ML17326B595 + (ML17326B595)
- ML17326B596 + (ML17326B596)
- ML17326B598 + (ML17326B598)
- ML17326B600 + (ML17326B600)
- ML17326B601 + (ML17326B601)
- ML17326B602 + (ML17326B602)
- ML17326B603 + (ML17326B603)
- ML17326B604 + (ML17326B604)
- ML17326B606 + (ML17326B606)
- IR 05000315/1989004 + (ML17326B607)
- ML17326B609 + (ML17326B609)
- ML17326B611 + (ML17326B611)
- BSEP 17-0108, Request for Emergency License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel Generator Completion Times and Suspension of Surveillance Requirements + (ML17326B619)
- ML17328A002 + (ML17328A002)
- ML17328A005 + (ML17328A005)
- ML17328A007 + (ML17328A007)
- ML17328A009 + (ML17328A009)
- 05000315/LER-1989-004-01, :on 890324,discovered That Containment Type B & C Leakage Exceeded Limiting Condition for Operation.Caused by Degradation of Isolation Valve Seating Surfaces. Containment Isolation Valves Being Repaired + (ML17328A010)