- ML17326A609 + (ML17326A609)
- 05000316/LER-1980-012-03, /03L-0:on 800305,while Performing Surveillance Test,Steam Generator Water Level low-low Trip Bistable Found to Trip at 11:05% Narrow Range Instrument Span.Cause Unstated.Bistable Recalibr & Returned to Svc + (ML17326A610)
- ML17326A627 + (ML17326A627)
- ML17326A632 + (ML17326A632)
- PNO-III-80-049, on 800314,licensee Notified Inspector That Small Unexplained Radioactive Release Via Auxiliary Bldg Stack Was in Progress.Caused by Leaking Relief Valve. Failed Fuel Sys Isolated + (ML17326A633)
- ML17326A634 + (ML17326A634)
- ML17326A635 + (ML17326A635)
- ML17326A636 + (ML17326A636)
- ML17326A637 + (ML17326A637)
- ML17326A638 + (ML17326A638)
- 05000316/LER-1980-013-03, /03L-0:on 800307,during Normal Operation,Circuit Breaker for R-11 & R-12 Sample Pump Tripped.Caused by Failure of Rubber Spider in Lovejoy L-100 Coupling.Complete Coupling Replaced & Air Sampler Tested + (ML17326A639)
- ML17326A641 + (ML17326A641)
- ML17326A642 + (ML17326A642)
- 05000316/LER-1980-014-03, /03L-0:on 800216,during Surveillance Test, Proximity Switch for D Main Turbine Stop Valve Fell Off Mounting Bracket.Caused by Threads in Mounting Bracket Being Stripped.Hole Retapped to Larger Size + (ML17326A643)
- ML17326A644 + (ML17326A644)
- PNO-III-80-049A, on 800314,Region 3 Received Notification of Unplanned Radioactive Gas Release.Caused by Relief Valve Lifting in in-line Failed Fuel Detection Sys Due to Overthrottling of Valve Downstream + (ML17326A645)
- ML17326A647 + (ML17326A647)
- ML17326A648 + (ML17326A648)
- ML17326A651 + (ML17326A651)
- 05000315/LER-1980-004, Forwards LER 80-004/03L-0 + (ML17326A652)
- ML17326A653 + (ML17326A653)
- ML17326A655 + (ML17326A655)
- ML17326A656 + (ML17326A656)
- ML17326A657 + (ML17326A657)
- ML17326A658 + (ML17326A658)
- ML17326A659 + (ML17326A659)
- ML17326A660 + (ML17326A660)
- ML17326A661 + (ML17326A661)
- ML17326A662 + (ML17326A662)
- 05000316/LER-1980-016-03, /03L-0:on 800322,while Performing Routine Panel Insp,Operator Discovered Cast RHR Pump Suction Breaker IMO-310 Open.Cause Not Determined.Operators Have Been Alerted to Keep Close Watch on Panel Indicators + (ML17326A663)
- 05000316/LER-1980-017-03, /03L-0:on 800321,during Normal Operation,Tdafp Trip & Throttle Valve Tripped & Could Not Be Reset.Caused by Defective Reset Solenoid.Coil Replacement Not Effective.Trip Linkage Reset Manually.New Coil & Linkage Adjusted + (ML17326A664)
- ML17326A665 + (ML17326A665)
- 05000316/LER-1980-015, Forwards LER 80-015/03L-0 + (ML17326A666)
- ML17326A668 + (ML17326A668)
- 05000316/LER-1980-015-03, /03L-0:on 800325,during Auxiliary Feed Pump Retest Auxiliary Feed Valve FMO-221 for Steam Generator 2 Did Not Operate.Caused by Armature Lead from Limitorque Valve Operator Being Pulled Out of Wire Lug.New Lug Crimped + (ML17326A669)
- ML17326A670 + (ML17326A670)
- ML17326A671 + (ML17326A671)
- 05000315/LER-1980-005-03, /03L-0:on 800321,discovered That Unit 1 Axial Power Distribution Monitoring Sys & P-250 Axial Power Distribution Monitoring Sys Limits Were Incorrect.Caused by Personnel Using Unit 2 Fq & K(Z) Limits in Computer Program + (ML17326A672)
- 05000315/LER-1980-006-03, /03L-0:on 800324,during Surveillance Test,Unit 1 650-ft Elevation Airlock Door Leakage of 130CFH Was Found.No Cause for Leak Found.Retest Performed W/Satisfactory Results + (ML17326A673)
- ML17326A674 + (ML17326A674)
- ML17326A675 + (ML17326A675)
- ML17326A676 + (ML17326A676)
- ML17326A677 + (ML17326A677)
- 05000316/LER-1980-018-03, /03L-0:on 800331,during Normal Operation,Radiation Monitor R-11 Alarmed & Would Not Reset.Caused by Wear of Pump.Pump & Rubber Spider Replaced + (ML17326A681)
- 05000315/LER-1980-007-03, /03L-0:on 800326,while Revising Surveillance Test Procedure for Containment Spray Sys,Some Valves in Sys Flow Path Were Discovered Not Being Cycled at Required Intervals. Caused by Personnel Overlooking Test Frequency Differ + (ML17326A682)
- ML17326A683 + (ML17326A683)
- ML17326A684 + (ML17326A684)
- 05000315/LER-1980-004-03, While Performing Scan Sequence, One of Two Detectors in Use for Axial Power Distribution Monitoring Sys Became Inoperable.Caused by Stretched Helex in Detector & Damaged Drive Wheel + (ML17326A685)
- ML17326A687 + (ML17326A687)
- 05000316/LER-1980-019-03, /03L-0:on 800411,during Rapid Power Reduction to Remove West Main Feed Pump from Svc,Axial Flux Difference Was Forced Out of Target Band Defined in Tech Spec.Caused by Coupling Failure + (ML17326A688)
- IR 05000331/2017010 + (ML17326A691)