c REGUL'ATQRY INFORMATION DISTRIBUTION SYSTEM.
(R IDS)
ACCESSION NBR:8000080544 DOC ~ DATE: 80/04/01 NOTARIZED'O DOCKET FACIL:50 315 Donald C.
Cook Nuclear Power Planti Unit ii Indiana 8
05000315 50 316 Donald C,
Cook Nuclear Power Planti Unit 2i Indiana 8
05000316 AUTH BYNAME AUTHOR AFFILIATION DOLANiJ ~ ED Indiana 8 Michigan Electric Co."
RECIP ~ NAME RECIPIENT" AFFILIATION DENTONeH ~ RE Office of Nuclear Reactor Regulation
SUBJECT:
Forwards evacuation time estimates in response to NRC 791129 info request. Time required to-evacuate schools 8 nutsing homes under adverse 8 favorable conditions assumed to be 2-h after notification 8 4-h for hospitals.
DISTRIBUTION CODE:
A043S COPIES RECEIYED:LTR ~- ENCL g SIZE:. Zg TITLE: Emergency Planning Implementation (OL Stage)
Mwa NOTES; ACTION; RECIPIENT ID CODE/NAME 07 BC +~
gy INTERNAL 01 REG FILE 05 EPB DOR 17 TA/EDO 19 ENGR BR 21 PLANT SYS BR 23 EFLT TRT SYS GRIME.S r 8 ~
STATE PROGRAMS EXTERNAL: 03 LPDR 16 ACRS COPIES LlTTR ENCI 0
7 7
1 1
2 2
1 1
1 1
1 1
1 1
1 1
2 2
1 1
16 16, RECIPIENT ID CODE/NAME 02 NRC PDR 15 I 8
E 18 CORE PERF BR 20 REAC SFTY BR 22 EEB 20 BR INKMAN OELO 04 NSIC COPIES LTTR ENCL 1
1 2
2 1
1 1
1 1
1 1
1 0
1 1
bp TOTAL, NUMBER OF COPIES REQUIRED!
LTTR ~
ENCL
1',
W
INDIANA R MICHIGAN ELECTRIC COMPANY P. O.
BOX 18 BOWLING GREEN STATION NEW YORK, N. Y. 10004 Donald C. Cook Nuclear Plant Units Nos.
1 and 2
Docket Nos.
50-315 and 50-316 License Nos.
1980 AEP:NRC:00328 RE:
EVACUATION TIME ESTIMATES Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.
20555
Dear Mr. Denton:
This letter responds to Mr. Brian K. GrimesI letter of November 29, 1979, received on December 7, 1979.
Mr. Grimes I letter requested information regarding emergency evacuation.
A request for an extension of time to submit this answer was submitted to your office on January 23, 1980 via our letter No. AEP:NRC:00328A.
The attachment contains the evacuation time estimates prepared by the Office of Emergency Preparedness of the Berrien County Sheriff's Department.
Very truly yours, JED/ko Attachment, ohn E. Dolan Vice President cc:
R. C. Callen G. Charnoff R.
S. Hunter R.
W. Jurgensen D. V. Shaller - Bridgman PovS 5
ih 8 OO4080 W@+
ATTACHMENT TO AEP:NRC:00328
Back round Information The tables for favorable and adverse conditions provide the following information: 'Notifi'cati'on time, Public Preparation
- time, Movement time, Total Evacuation time, Confirmation time, and Evacuation plus Confirmation time for the given angular sectors having radii/
of 2, 5, 8, and 10 miles.
These time estimates are based on past ex-perience of the Berrien County Sheriff's Department (BCSD) evacuating its county, knowledge of the local area, and projected population dis-tribution for 1985 based on the Donald C.
Cook Nuclear Plant -
FSAR Tables 2.1-6 and 2.1-7 which were extrapolated from 1970 Census data.
To develop the estimates, calculations were first made for 45 sectors.
The estimates of Notification time assumed the use of the
- BCSD, and the Michigan State Police forces.
The number of people notified per unit time was assumed to increase as each police department becomes fully mobilized during the evacuation process.
Although notification would be made via broadcasts on local radio
- stations, the Notification time estimates are based on positive assurance of notification through the use of emergency patrols by police vehicles.
In each case, the time needed
-by the public to become prepared for evacuation (public preparation time) is assumed to be 20 minutes.
Movement time estimates represent tht time required for all people within a given sector to reach the outer edge from anywhere within the sector (See attached map for sector boundaries.)
The need for evacuation confirmation is a matter of great concern to the BCSD.
The corresponding time estimates show that the need to re-enter an affected sector presents a large risk to BCSD personnel, since the time needed for confi'rmation increases the danger of overexposure to those BCSD personnel i'nvolved in it.
Furthermore, the evacuation
- has, by then already taken place.
The concerns for increased protection ofIBCSD personne~l in ensupi'ng q htgL degpee, of'onfidence duping confipmati'on that the required evacuation has taken place, lead to what could be considered con-servative estimates of the times required to confirm evacuation.
In general, to determine the evacuation time estimates, the BCSD considered the I. number of people required to leave a given sector, the distance of.travel through f the sector, the number of evacuation routes available per sector, and normal I driving speeds for adverse and favorable conditions.
In all cases, except
- one, adverse conditions are meant to imply adverse weather such as winter storms.
The exception is in Sector K where the adverse con-dition is during the summer with Warren Dunes State Park at full capacity (approximately 22,000 people).
This park is located about 5 miles southwest of the Donald C.
Cook Nuclear Plant.
~
~
I The time required to evacuate schools and nursing homes under both adverse or favorable conditions was assumed to be 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after notification and preparation
- time, and the time required to evacuate hospitals was taken to be 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, following notification and preparation time.
0 k
III
'l 1
- IS I
JJ IS--
lt he Sg I
tt e>>
A
. H
~<<ee<<erL 8
N 0
SN Q
29 b
Af eerOe 2 L44t
~e
~
P
/////
31 Oy EGEIID
'TfAS'Tlt le/SNWAT TCOC IA4/IWAT STAT I44 fO ts/IIAAT IN AVCO LOCAL INAO llltORT'4 INAOSeOC tAAA j/i
/
10 ls Cs 2
0 L
r 13 ST 2
~>>rr err<<
4 20 IO 5
I 4 S
D 2T 26 eee re P
34 3S '
Y N
N 2M Rl eer I
2 6
E 5Mi I j l3 Id SAROOA IS Lerw
~ 4 N
eee<<e 0
K IA 9
9 8Mi I/
e
.;b2 2 I at 9 'j 20 at 22 23 IO Mi 26 R 0 2S D A.
30
~cere ee 2T 26 3
jt I-6
>>ew g\\II 9
lO 6
~9 G.H I wb I
~4 W
UC A NA N
Is K.
~rr
.22 t
al
~ewe O 22 H
23 al
~4 23 as~ I 26 ts 30 e
29
~ <<
~ <<rr>>
e <<<<
Il
,$~) v
~ I
SECTOR BCDEFGHJ 180.
FAVORABLE CONDITIONS Notification Time Public Preparation Time Movement Time Total Evacuation Time 2 Hi 3:30
- 20
- 15 4:05 5 Hi 5:00
- 20
- 20 5:40 8 Hi 5 00
- 20
- 40 6 00 10 Hi 5 00
- 20
- 45 6:05 Confirmation Time Evacuation plus Confiroation Time 3:50 7:55 12:00 17:40 24:00 30:00 29:00 35:05 SPECIAL CONSIDERATIONS-
~
~
SECTOR BCDE (90
)
FAVORABLE CONDITIONS Notification Time Public Preparation lime Movement Time
~tal Evacuation Time 2 Mi 1:10
- 20
- 10 1:40 5 Mi 2:40
- 20
- 15 3:15 5:00
- 20
- 15 5:35 10 Mi 5:00
- 20
- 35 5:55 Confirmation Time Evacuation plus Confirmation Time 2:00 3:40 7:00 10:15 14:00 19:35 17:00 22:35.
SPECIAL CONSIDERATIONS-
~~v<
SECTOR FGHJ (90')
FAVORABLE CONDITIONS Notification Time'ublic Preparation Time 1
Movement Time tal Evacuation Time 2 Mi 1:20
- 20
- 10 1:50 5 Mi 2:20
- 20
- 20 3:00 S.-Mi 4 00
- 20
- 20 4:40 10 Mi 5:00
- 20
- 20 5:40 Confirmation Time Evacuation plus Confirmation Time 1:50 2:40 5:00 8:00 10:15 14:55 12:00 17:40 SPECIAL CONSIDERATIONS-1
~
g; SECTOR BC (45
)
FAVORABLE CONDITIONS f
'oti fication Time Public Preparation Time ltovement Time I
I ~tal Evacuation Time I
Confirmation Time Evacuation plus Confirmation Time 2 Hi 0:20
.:20
- 10
- 50 1:00 1:50 5 Mi 1:30
- 20
- 15 2:05 4 00 6:05 8 Hi 3:30
- 20
- 15 4:05 7:45
.11:50 10 Hi 4:15
- 20
- 35 5'10 10 00 15:10 SPECIAL CONSIDERATIONS-Hemorial Hospital( 9:25 miles away)
Oles Homestead for the Aged Park Wayne Manor.
Shoreham Terrace
S ECTOR DE (45o)
FAVORABLE CONDITIONS 2 Mi 8 Mi 10 Mi Notification Time Public Preparation Time Movement Time o tal E vacua tion Time 50
- 20
- 10 1:20 1:10
- 20
- 15 2:30 2:30
- 20
- 15 3:05 2:45
=
- 20
- 15 3:20 Confirmation Time Evacua tion plus Confirmation Time 1:00 2:20 3:00 5:30 6:15 9:20 7:00 10: 20 SPECIAL CONSIDERATIONS-Fancher Adult Foster Care '
SECTOR FG (45 )
FAVORABLE CONDITIONS 2 Mi 8 Hi 10 N Notification Time Public Preparation Time Movement Time otal Evacuation Time
- 50
- 20
- 10 1:20 1:10
- 20
- 15 1:45 2:00
- 20
- 15 2:35 2
~ 15
- 20
- 20 2:55 Confirnetion Time Evacuation plus Confirmation Time
- 50 2:10 3:00 4'45 5:00 7:35 6:00 8:55 SPECIAL CONSIDERATIONS-
- Gateway, Inc.( Nursing home)
SECTOR HJ (45 )
FAVORABLE CONDITIONS gi Notification Time Public Preparation Time t1ovement Time Total E vacua tion Time 2 Hi
- 50
- 20
- 10 1:20 5 Ni 1:00
- 20 20 1 40 8 Hi
/
2:00
- 20
- 20 1:40 10 Hi 2:45
- 20
- 20 3:25 Confirma tion Time Evacuation plus Confirmation Time 1:00 2:20 2:00 3:40 5:15 6:55 6:00 9:25 SPECIAL CONSIDERATIONS-Bethany Retirement Home Jordan's Rest Home Lake Valley Adult Foster Care
SECTOR K
(22.5
)
FAVORAI3LE CONDITIONS Notification Time Public Preparation Time Movement Time Total Evacuation Time 2 Hi
- 25
- 20
- 15 1:00 5 Ni
- 50
- 20
- 15 1:25 8 Mi 2:00
- 20
- 15 2:35 10 Hi 2:30
- 20
- 15 3 05 Confirmation Time Evacuation plus Confirmation Time
- 45 1:45 1:00 2:25 1:45 4:20 4:00 7'05 SPECIAL CONSIDERATIONS-Warren Dunes
Notifica tion Time Public Preparation Time Movement Time Total Evacua tion Time
'B SECTOR BCDEFGHJ 180 ADVERSE CONDITIONS 2 Mi 3:50
- 20
- 20 4:30 5 Mi 5'00
- 20 1:00 6:20 8 Mi 6:00
- 20 1'15 7:35 10 Mi 6:00
- 20 1:30 7:50 Confirma tion Time Evacuation plus Confirmation Time 7:20 11:50 23:00
'29: 20 35:00 42: 35 45'00 52:50 SPECIAL CONSIDERATIONS-
Notification Time Public Preparation Time Movement Time To ta 1 Evacua ti on Time SECTOR BCDE (90
~
. ADVERSE'CONDITIONS 2 Mi 1:40
- 20
- 20 2:20 5 Mi 4'55
- 20
- 30 5'45 8 Mi 6:00
- 20
- 30 6:50 10 Mi 6:00
- 20 1:15 7:35 Confirmation Time Evacuation plus Confi~mation Time 4 00 6:20 14:00 19:45 22:00 25: 50 26: 30 34:05 SPECIAL CONSIDERATIONS-
'3 Notification Time Public Preparation Time thvement Time Total Evacuation Time SECTOR FGHJ (90
)
ADVERSE CONDITIONS 2 Mi 2:10
- 20
- 20 2:50 5 Ni 3:30
- 20
- 30 4:20 8 Mi 6:00
- 20
~ 45 7 05 10 Hi
.6:00
- 20
- 45 7:05 Confirmation Time Evacuation plus Confirmation Time 3:20 6:10.
8:45 13:05 13:30 20: 35 18:15 25:20 SPECIAL CONSIDERATIONS-
Notification Time Public Preparation Time Movement Time Total Evacuation Time SECTOR BC (45 C)
ADVERSE CONDITIONS 2 Mi
- 40
- 20
- 20 1:20 5 Hi 3:30
- 20
- 30 4:20 6:30
- 20
- 30 7:20 10 Mi 7:00
- 20 1:15 8:35 Confirmation Time Evacuation plus Confirmation Time 2;00 3:20 8:00 12: 20 15:00 22: 20 17:00 25:35 SPECIAL CONS IDERATIONS Memorial Hospital Ol es Homes tead.for the Aged Park Wayne Manor, Shoreham Terrace
Notifica tion Time Public Preparation Time Novement Time Total Evacuation Time SECTOR DE (45
)
ADVERSE CONDITIONS 2 Hi 1:00
- 20
- 20 1:40 1:25
- 20.
- 25 2:10 8 Hi 3:00
- 20
- 30 3:50 10 Ni 3:15
- 20
- 30 4:05 Confirmation Time Evacuation plus Confirmation Time 2:00 3:40 6'00 8:10 7:00 10:50 9:30 13:35 SPECIAL CONS IDERATIONS-Fancher Adult Foster Care
Noti fication Time Public Preparation Time lhvement Time Total Evacuation Time 6
SECTOR FG (45
)
ADVERSE CONDITIONS 2 Ni 1:00
- 20
- 20 1:40 5 Mi 1:45
- 20
- 25 2:30 8 Hi 3 00
- 20
- 30 4:50 10 Hi 3 30
- 20
- 45 4:35 Confirmation Time Evacuation plus Confirmation Time 2:00 3:40 6:15 8:45 6:30 11: 20 10:00 14: 35 SPECIAL CONSIDERATIONS-
- Gateway, Inc.
~
Noti fication Time Public Preparation Time Movement Time Total Evacua tion Time fi SECTOR HJ (45
)
ADVERSE CONDITIONS 2 Hi 1:10
- 20
- 10 1:40 1:45
- 20
- 30 2:35 3:00
- 20
- 45 4:05 10 Mi 3:20
- 20
- 45 4:25 Confirmation Time Evacuation plus Confirmation Time V
1:20 3:00 2:30 5:05 7:00 11: 05 8:15 12:40 SPECIAL CONSIDERATIONS-Bethany Retirement Home Jordan's Rest Home Lake Valley Adult: Foster Care
C C
, ~
Noti fication Time-Public Preparation Time Movement Time Total Evacuation Time SECTOR K (22.5o)
ADVERSE CONDITIONS 2 Mi
- 40
- 20
- 25 1:25 5 Mi 1:00
- 20 1:15 2:35 8 Mi 2:30 20 1:15 4:05 10 Mi 3:00
- 20 1:15 4:35 C.
Confirmation Time Evacuation plus Confirmation Time 1:15 2:40 1:30 4 05 2:30 6:35 6:00 10: 35 SPECIAL CONS IDERATIONS-Warren Dunes
l t