ML20128H1266 June 1985Office of Nuclear Reactor Regulation
Lazo L
Summary of 831219 Meeting W/Util & S&W in Bethesda,Md Re Util Equipment Qualification Program.Meeting Agenda & Supporting Documentation EnclMeeting
ML20205Q10523 May 1986Duquesne Light Company
Carey J
Forwards Vols 1-1C to Equipment Qualification Rept - Environ Qualification of Class 1E Electrical Equipment. Representative Sample of Equipment Will Be Installed & Available for Insp in Support of NRC AuditOther
ML20206E61916 June 1986Tam P
Office of Nuclear Reactor Regulation
Notification of 860701 Meeting W/Util in Bethesda,Md to Discuss Technical Issues Re Util 860523 Equipment Qualification Rept,Identified as SER Confirmatory Issue 14, in Preparation for NRC AuditMeeting
ML20203G48828 July 1986Tam P
Office of Nuclear Reactor Regulation
Summary of 860701 Meeting W/Util,Westinghouse & S&W in Bethesda,Md Re Preparation for Onsite Equipment Qualification Audit.Agenda & Attendee List Encl.Audit Expected to Take Place in Aug 1986Meeting
ML20205C3284 August 1986Duquesne Light Company
Carey J
Forwards Addendum 1 to 2BVM-166, Sqrt & Pump & Valve Operability Review Team (Pvort) Audit Program & Updated Master Equipment List,Per Sqrt/Pvort 860723 Premeeting.List Submitted to Support NRC 860930 AuditMeeting
ML20210F60220 September 1986Duquesne Light Company
Carey J
Forwards Rev 1 to Vols 1,1A,1B & 1C to Equipment Qualification Rept - Environ Qualification of Class 1E Electrical Equipment. Review & Schedule of NRC Audit Requested.List of Specs & Status of Util Response Also EnclOther
ML20215N20123 October 1986Tam P
Office of Nuclear Reactor Regulation
Discusses Results of 860701 Meeting W/Util & Contractor in Preparation for Equipment Qualification Onsite Review.Onsite Review Scheduled for 861117-21.Access for Review Team Members RequestedMeeting
ML20214E58819 November 1986Tam P
Office of Nuclear Reactor Regulation
Notification of 861120 Meeting W/Util in Shippingport,Pa to Discuss Applicant Personnel Findings Made During Equipment Qualification Site AuditMeeting
ML20214V9043 December 1986Duquesne Light Company
Woolever E
Forwards Updated Environ Qualification Program for Safety- Related Mechanical Equipment in Response to FSAR Questions 270.2 & 270.3 Identified in FSAR Amend 4.Qualification Methodology & Results DiscussedOther
ML20207D47319 December 1986Duquesne Light Company
Carey J
Forwards Supplemental Info Re Evaluation of Superheated Steam Blowdown on Environ Qualification of Facility Equipment,Per 861125 Telcon.Response Provides Addl Info on Computer Codes Utilized in Superheat EvaluationSupplement
ML20212J5434 March 1987Duquesne Light Company
Carey J
Forwards Response to Specific & Generic Comments from Nrc/ NRR Environ Qualification Audit on 861118-20.Info Indicates That Action to Address Specific Comments Completed & Action to Address Generic Comments Prior to Fuel Load UnderwayOther
ML20207R0575 March 1987Tam P
Office of Nuclear Reactor Regulation
Forwards Comments for Resolution Re SER Confirmatory Issue 14 Identified During Equipment Qaulification Review Team 861118-20 Audit.Response Requested within 45 Days of Ltr ReceiptOther
ML20205G37924 March 1987Duquesne Light Company
Carey J
Forwards Responses to NRC Requests for Info Re Environ Qualification Program,Including High Energy Line Break W/ Superheat & Qualification Methodology for SubmergenceOther
ML20205F93526 March 1987Duquesne Light Company
Sieber J
Forwards Environ Qualification of Safety-Related Mechanical Equipment, Including Rev 1 to Books 1-3 Re Masonelian air-operated Valves,Rev 4 Re Xomox Plug Valves & Rev 5 Re Pacific Charging Pumps,Per P Tam 870317 TelecopyOther
ML20214J67018 May 1987Duquesne Light Company
Carey J
Notifies of Completion of Environ Qualification (EQ) Effort for Facility EQ Packages in Compliance w/10CFR50.49. Potential 10CFR50.55(e) Items Re Improper Sealing of EQ Program Equipment Will Be Submitted within 30 DaysOther
ML20214J49125 May 1987Duquesne Light Company
Carey J
Interim Significant Deficiency Repts 87-16 & 87-17 Re Conduit Sealing of 50 Class 1E Items.All Physical Work Re Re Environ Qualification Program Complete W/Exception of Four Bisco SealsOther