Letter Sequence Other |
|---|
|
|
MONTHYEARML20128H1261985-06-0606 June 1985 Summary of 831219 Meeting W/Util & S&W in Bethesda,Md Re Util Equipment Qualification Program.Meeting Agenda & Supporting Documentation Encl Project stage: Meeting ML20205Q1051986-05-23023 May 1986 Forwards Vols 1-1C to Equipment Qualification Rept - Environ Qualification of Class 1E Electrical Equipment. Representative Sample of Equipment Will Be Installed & Available for Insp in Support of NRC Audit Project stage: Other ML20206E6191986-06-16016 June 1986 Notification of 860701 Meeting W/Util in Bethesda,Md to Discuss Technical Issues Re Util 860523 Equipment Qualification Rept,Identified as SER Confirmatory Issue 14, in Preparation for NRC Audit Project stage: Meeting ML20203G4881986-07-28028 July 1986 Summary of 860701 Meeting W/Util,Westinghouse & S&W in Bethesda,Md Re Preparation for Onsite Equipment Qualification Audit.Agenda & Attendee List Encl.Audit Expected to Take Place in Aug 1986 Project stage: Meeting ML20205C3281986-08-0404 August 1986 Forwards Addendum 1 to 2BVM-166, Sqrt & Pump & Valve Operability Review Team (Pvort) Audit Program & Updated Master Equipment List,Per Sqrt/Pvort 860723 Premeeting.List Submitted to Support NRC 860930 Audit Project stage: Meeting ML20210F6021986-09-20020 September 1986 Forwards Rev 1 to Vols 1,1A,1B & 1C to Equipment Qualification Rept - Environ Qualification of Class 1E Electrical Equipment. Review & Schedule of NRC Audit Requested.List of Specs & Status of Util Response Also Encl Project stage: Other ML20215N2011986-10-23023 October 1986 Discusses Results of 860701 Meeting W/Util & Contractor in Preparation for Equipment Qualification Onsite Review.Onsite Review Scheduled for 861117-21.Access for Review Team Members Requested Project stage: Meeting ML20214E5881986-11-19019 November 1986 Notification of 861120 Meeting W/Util in Shippingport,Pa to Discuss Applicant Personnel Findings Made During Equipment Qualification Site Audit Project stage: Meeting ML20214V9041986-12-0303 December 1986 Forwards Updated Environ Qualification Program for Safety- Related Mechanical Equipment in Response to FSAR Questions 270.2 & 270.3 Identified in FSAR Amend 4.Qualification Methodology & Results Discussed Project stage: Other ML20207D4731986-12-19019 December 1986 Forwards Supplemental Info Re Evaluation of Superheated Steam Blowdown on Environ Qualification of Facility Equipment,Per 861125 Telcon.Response Provides Addl Info on Computer Codes Utilized in Superheat Evaluation Project stage: Supplement ML20212J5431987-03-0404 March 1987 Forwards Response to Specific & Generic Comments from Nrc/ NRR Environ Qualification Audit on 861118-20.Info Indicates That Action to Address Specific Comments Completed & Action to Address Generic Comments Prior to Fuel Load Underway Project stage: Other ML20207R0571987-03-0505 March 1987 Forwards Comments for Resolution Re SER Confirmatory Issue 14 Identified During Equipment Qaulification Review Team 861118-20 Audit.Response Requested within 45 Days of Ltr Receipt Project stage: Other ML20205G3791987-03-24024 March 1987 Forwards Responses to NRC Requests for Info Re Environ Qualification Program,Including High Energy Line Break W/ Superheat & Qualification Methodology for Submergence Project stage: Other ML20205F9351987-03-26026 March 1987 Forwards Environ Qualification of Safety-Related Mechanical Equipment, Including Rev 1 to Books 1-3 Re Masonelian air-operated Valves,Rev 4 Re Xomox Plug Valves & Rev 5 Re Pacific Charging Pumps,Per P Tam 870317 Telecopy Project stage: Other ML20214J6701987-05-18018 May 1987 Notifies of Completion of Environ Qualification (EQ) Effort for Facility EQ Packages in Compliance w/10CFR50.49. Potential 10CFR50.55(e) Items Re Improper Sealing of EQ Program Equipment Will Be Submitted within 30 Days Project stage: Other ML20214J4911987-05-25025 May 1987 Interim Significant Deficiency Repts 87-16 & 87-17 Re Conduit Sealing of 50 Class 1E Items.All Physical Work Re Re Environ Qualification Program Complete W/Exception of Four Bisco Seals Project stage: Other 1986-07-28
[Table View] |
Text
_
5 a
'A@
2NRC-7-057 Bemr VWI No. 2 Unit Project Organization Telecopy 3-Ext 160 P.O. Box 328 March 26,1987 Shippingport, PA 15077 United States Nuclear Regulatory Conmission ATTN:
Document Control Desk Washington, DC 20555
SUBJECT:
Beaver Valley Power Station - Unit No. 2 Docket No. 50-412 Environmental Qualification of Safety Related Mechanical Equipment Gentlemen:
Submitted for your review at this time are (4) copies of Equipment Quali-i_
fications files for the following purchase orders:
1)
File 001-09 Pacific charging pumps
- 2) File 091-01 Xomox Plug valves
- 3) File 651-01 Masonelian Air Operated Valves g
It is understood that these are three files Mr. H. Walker selected for review per a telecopy from Mr. P. Tan dated March 17, 1987.
Any questions or requests for additional information should be coordinated through Mr. C. L. Hill who can be contacted at (412) 393-7840.
DUQUESNE LIGHT COMPANY
.A n.--
J. D. Sieber ce President, Nuclear CLH/ijr NR/CLH/SR/EQP Attachments AR/NAR cc: Mr. P. Tam, Project Manager w/o attachments
,/
Mr. J. Beall, NRC Sr. Resident Inspector w/o attachments Ms. A. Asars, NRC Resident Inspector w/o attachments Mr. H. Walker, NRC w/o attachments INP0 Records Center w/o attachments 0 3 (D g
3 Je. d 0703310339 870326
\\w PDR ADOCK 0500 2
e
'e
'd
- Unit:d States Nuclear R:gulatory Commission Environmental Qualification of Safety Related Mechanical Equipment i
Page 2 COMMONWEALTH OF PENNSYLVANIA )
)
SS:
COUNTY OF BEAVER
)
On this,fdd day of h A/l.
/[h/, before me, a Notary Public in and for said Comonwealth and County, personally appeared J.
D. Sieber, who being duly sworn, deposed and said that (1) he is Vice President of Duquesne Light, (2) he is duly authorized to execute and file the foregoing Submittal on behalf of said Company, and (3) the statements set forth in the Submittal are true and correct to the best of his knowledge.
4 D
Notary Public ELVA G. LESONDAK, NOTARY PUBLIC SHIPPINGPORT, BEAVER COUNTY MY COMMISSION EXPIRES OCTOBER 20,1990