2NRC-6-121 (412) 643-5200 Beaver Valley No. 2 Unit Project Organization Telecopy (412) 643-5200 Ext.160 u o QG , Dec. 3, 1986 Shippingport, PA 15077 Mr. Harold R. Denton Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: Mr. Peter Tam, Project Manager Division of PWR Licensing - A Office of Nuclear Reactor Regulation

SUBJECT:

Beaver Valley Power Station - Unit No. 2 Docket No. 50-412 Environmental Qualification of Safety Related Mechanical Equipment Gentlemen:

Submitted for your review at this time are six (6) copies of the updated Environmental Qualification Progran for Safety Related Mechanical Equipment.

This progran has been performed by Duquesne Light Company (DLC) in response to FSAR Questions 270.2 and 270.3 identified in FSAR Amendment 4 (2NRC-3-096, dated December 2,1983).

The progran as revised contains the following information:

1) Qualification methodology utilized
2) Detailed master listing of equipment included
3) Qualification results It is understood that thre e - items will be chosen by the NRC for detailed revi ew . Extensive back-up documentation and additional information is avail-able in conjunction with the progran and will be transmitted to you for those items selected.

The evaluation's results are now complete and DLC has initiated steps to qualify that equipment which has been identified as not having the ability to withstand the postulated environments (Approximately 5% of equipm. included in the prooran). Equipment items with the EQ status' code of "I" oenoted on this master list are included in this category. This generally indicates that a particular type and/or model number is not well suited for a specific area (i.e., containment) as opposed to the item lacking any subs t ant i al qualification levels.

A K 00 2 o PDR s6

United States Nuclear Regulatory Commission Mr. Harold R. Denton Environmental Qualification of Safety Related Mechanical Equipment Page 2 ,

1 All requests for additional information should be coordinated through Mr.

C. L. Hill who can be contacted at (412) 393-7840.

DUQUESNE LIGHT COMPANY By / g Q. J.~Woolever Vice President Special Nuclear Projects CLH/ijr NR/EQ/ MECH /EQP At nts AR cc: Mr. P. Tam, Project Manger J. Beall, Senior Resident Inspector L. Prividy, Resident Inspector H. Walker, NRC NRC Document Control Desk

j United States Nuclear Regulatory Commission Mr. Harold R. Denton Environmental Qualification of Safety Realted Mechanical Equipment Page 3 COMMONWEALTH OF PENNSYLVANIA )

SS:

COUNTY OF BEAVER l On this // bay of [4fX[ , /[ , before me, a Notary Public in and for said Commonwealth and County, personally appeared E. J. Woolever, who being duly sworn, deposed and said that (1) he is Vice President of Duquesne Light, (2) he is duly authorized to execute and file the foregoing Submittal cn behalf of said Company, and (3) the statements set forth in the Submittal are true and correct to the best of his knowledge, h Afd) k Notary