Issue date | Title | Topic | |
---|---|---|---|
ML18152A281 | 12 October 1999 | Technical Basis for Elimination of Nozzle Inner Radius Insps (for Nozzles Other than Reactor Vessel),Technical Basis for ASME Section XI Code Case N-619. | Liquid penetrant |
ML18152B353 | 30 September 1999 | Monthly Operating Repts for Sept 1999 for Surry Power Station,Units 1 & 2.With 991012 Ltr | Reserve Station Service Transformer |
ML20249C849 | 30 September 1999 | 1999 Third Quarter Rept of Completed Changes,Tests & Experiments Evaluated,Per 10CFR50.59(b)(2), for Dresden Nuclear Power Station. with | Temporary Modification |
ML20217A169 | 22 September 1999 | Part 21 Rept Re Engine Sys,Inc Controllers,Manufactured Between Dec 1997 & May 1999,that May Have Questionable Soldering Workmanship.Caused by Inadequate Personnel Training.Sent Rept to All Nuclear Customers | |
ML18152B665 | 31 August 1999 | Monthly Operating Repts for Aug 1999 for Surry Power Station Units 1 & 2.With 990915 Ltr | Temporary Modification |
ML18152B441 | 27 August 1999 | LER 99-005-00:on 990731,effluent Radiation Monitors Were Declared Inoperable.Caused by Degraded Heat Trace Circuits for Monitors Sample Suction Line.Degraded Heat Trace Circuit Was Replaced & Addl Heat Trace Is Being Installed | |
ML18152B442 | 27 August 1999 | LER 99-006-00:on 990802,determined That Plant Was Outside of App R Design Basis Due to Fire Barrier Deficiencies. Caused by Original Plant Design Deficiencies.Fire Watches Were Established & Mods Have Been Completed.With 990827 Ltr | Safe Shutdown Fire Barrier Fire Watch |
ML18152B377 | 13 August 1999 | LER 99-004-00:on 990714,TS Violation Due to non-safety Related Fans Effect on CR Boundary Was Noted.Cause of Event Has Not Yet Been Determined.Cable Spreading Room Doors Were Operned to Reduce Pressure in Rooms | |
ML18151A398 | 13 August 1999 | SPS Unit 2 ISI Summary Rept for 1999 Refueling Outage. | Hydrostatic |
ML18152B379 | 31 July 1999 | Monthly Operating Repts for July 1999 for Surry Power Station,Units 1 & 2.With 990811 Ltr | Temporary Modification Biofouling |
ML20210R608 | 31 July 1999 | Monthly Operating Repts for July 1999 for Dresden Nuclear Power,Units 1,2 & 3.With | |
ML18152B391 | 30 June 1999 | Monthly Operating Repts for June 1999 for Surry Power Station,Units 1 & 2.With 990713 Ltr | |
ML20209E129 | 30 June 1999 | Monthly Operating Repts for June 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With | |
ML20210D307 | 30 June 1999 | Corrected Page 8 to MOR for June 1999 for DNPS Unit 3 | |
ML20209J348 | 30 June 1999 | 1999 Second Quarter Rept of Completed Changes,Tests & Experiments, Per 10CFR50.59.With | Safe Shutdown Temporary Modification |
ML18152B434 | 31 May 1999 | Monthly Operating Repts for May 1999 for Surry Power Station,Units 1 & 2.With 990614 Ltr | Temporary Modification Biofouling |
ML20195E240 | 31 May 1999 | Rev 2 to COLR for SPS Unit 2 Cycle 16 Pattern Ag | |
ML20195G638 | 31 May 1999 | Monthly Operating Repts for May 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With | Enforcement Discretion |
ML20195B259 | 19 May 1999 | Rev 66a to CE-1-A,consisting of Proposed Changes to QAP for Dnps,Qcs,Znps,Lcs,Byron & Braidwood Stations | Offsite Dose Calculation Manual Process Control Program |
ML18152B418 | 18 May 1999 | LER 99-002-00:on 990425,MSSVs Tested Out of Tolerance for as Found Setpoint.Caused by Minor Setpoint Drift.No Immediate Action Required.Deviation Rept Submitted for Each Valve.With 990518 Ltr | Time of Discovery |
ML20206N282 | 30 April 1999 | Monthly Operating Repts for Apr 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With | |
ML18152B416 | 30 April 1999 | Monthly Operating Repts for Apr 1999 for Surry Power Station Units 1 & 2.With 990512 Ltr | Temporary Modification |
ML18152B411 | 28 April 1999 | LER 99-003-00:on 990331,potential Loss of Charging Pumps Was Noted.Caused by Main CR Fire.Station Deviation Was Issued on 990331.With 990428 Ltr | Safe Shutdown Fire Protection Program Fire Watch Hourly Fire Watch |
ML20205N749 | 31 March 1999 | Monthly Operating Repts for Mar 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With | |
ML20206B190 | 31 March 1999 | First Quarter Rept of Completed Changes,Tests & Experiments Per 10CFR50.59 for Dresden Nuclear Power Station. with | Shutdown Margin Fire Barrier Temporary Modification Severe Accident Management Guideline |
ML18152B651 | 31 March 1999 | Monthly Operating Repts for Mar 1999 for Surry Power Station Units 1 & 2 | |
ML18153A274 | 29 March 1999 | LER 99-002-00:on 990301,prematurely Released Fire Watches Resulted in Violation of TS 3.21.B.7.Caused by Inadequate Procedure.Procedure for Opening & Sealing Fire Stops Was Revised on 990212 | Fire Barrier Fire Protection Program Fire Watch |
ML18153A268 | 19 March 1999 | LER 98-013-01:on 981122,turbine/reactor Tripped on High Due to Short Circuit in Summator for MSL C Loop Channel III Flow Transmitter.Replaced 1-MS-FT1494 Summator & Module Repair Procedure Revised.With 9903190 Ltr | Shutdown Margin |
ML20207M692 | 28 February 1999 | Monthly Operating Repts for Feb 1999 for Dresden Nuclear Power Station,Units 1,2 & 3.With | Hydrostatic |
ML18152B733 | 28 February 1999 | Monthly Operating Repts for Feb 1999 for Surry Power Station,Units 1 & 2.With 990310 Ltr | Temporary Modification |
ML20207E931 | 26 February 1999 | Part 21 Rept Re Sprague Model TE1302 Aluminum Electrolytic Capacitors with Date Code of 9322H.Caused by Aluminum Electrolytic Capacitors.Affected Capacitors Replaced | |
ML18152B542 | 31 January 1999 | Monthly Operating Repts for Jan 1999 for Surry Power Station,Units 1 & 2.With 990210 Ltr | |
ML18151A303 | 29 January 1999 | ISI Summary Rept for 1998 Refueling Outage,Including Form NIS-1, Owners Rept for ISIs & Form NIS-2, Owners Rept for Repairs & Replacements. | |
ML20199M089 | 22 January 1999 | Part 21 Rept Re Failure of Square Root Converters.Caused by Failed Aluminum Electrolytic Capacitory Spargue Electric Co (Model Number TE1302 with Mfg Date Code 9322H).Sent Square Root Converters Back to Mfg,Barker Microfarads,Inc | |
ML18152B726 | 21 January 1999 | LER 99-001-00:on 981222,auxiliary Feedwater Pipe Support Missed Surveillance.Caused by Personnel Error.Station Deviation Rept Was Submitted.Two Supports in Question Received Required Code Insp & Were Found Acceptable | Missed surveillance |
ML20199C895 | 31 December 1998 | Monthly Operating Repts for Dec 1998 for Dnps,Units 1,2 & 3 | |
ML20205M706 | 31 December 1998 | Unicom Corp 1998 Summary Annual Rept. with | |
ML20199D326 | 31 December 1998 | 10CFR50.59 SER for 1998-04 Quarter, of Changes,Tests & Experiments.With | Safe Shutdown Process Control Program |
ML18152B601 | 31 December 1998 | Monthly Operating Repts for Dec 1998 for Surry Power Station,Units 1 & 2.With 990115 Ltr | Temporary Modification Turbine Missile Biofouling |
ML18152B578 | 16 December 1998 | LER 98-014-00:on 981126,manual Reactor Trip in Response to Main Feedwater Regulating Valve Failure Occurred.Caused by Dislocation of Retaining Clip in Positioner.Control Room Operators Placed Unit in Safe,Shutdown Condition | Shutdown Margin |
ML18152B581 | 16 December 1998 | LER 98-013-00:on 981122,turbine/reactor Trip on High SG Level Occurred.Caused by Instrument Failure.Control Room Operators Placed Unit in Safe,Shutdown Condition | Shutdown Margin |
ML18152B712 | 4 December 1998 | LER 98-S01-00:on 981105,noted Failure to Deactivate Station Access Badge.Caused by Human Error.Licensee Will Now Deactivate Station Badges Before Clearance Is Revoked & Process for Badge Deactivations Have Been Strengthened | Fitness for Duty |
ML18152B704 | 1 December 1998 | LER 98-012-00:on 981102,noted That EDGs Were Concurrently Inoperable.Caused by Required Testing Per TS 3.16.B.1.a.2. Redundant EDG Was Returned to Svc within Two Hour Period, Following Satisfactory Testing.With 981201 Ltr | |
ML20197G859 | 30 November 1998 | Monthly Operating Repts for Nov 1998 for Dresden Nuclear Power Station.With | |
ML18152B708 | 30 November 1998 | Rev 0 to COLR for Surry 1 Cycle 16,Pattern Un. | |
ML18152B572 | 30 November 1998 | Monthly Operating Repts for Nov 1998 for Surry Power Station,Units 1 & 2.With 981214 Ltr | Temporary Modification |
ML20196J006 | 19 November 1998 | Rev 66 to Topical Rept CE-1-A, QA Program | Offsite Dose Calculation Manual Coatings Process Control Program Fire Protection Program |
ML20196A419 | 19 November 1998 | Safety Evaluation Accepting QA TR CE-1-A,Rev 66 Re Changes in Independent & Onsite Review Organization by Creating NSRB | |
ML18152B616 | 6 November 1998 | LER 98-011-00:on 981008,diesel Driven Fire Pump Failed to Start During Performance of Monthly Operability Test.Caused by Faulty Overspeed Trip Device Failure.Diesel Driven Fire Pump Declared Inoperable | |
ML18152B624 | 31 October 1998 | Monthly Operating Repts for Oct 1998 for Surry Power Station Units 1 & 2.With 981111 Ltr | Temporary Modification Coast down |