ML17300B33014 September 1999Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Making Listed Administrative Changes to TS 5.5.2 & TS 5.6.2 Re Primary Coolant Sources Outside Containment & Annual Radiological Environmental Operating ReptAnnual Radiological Environmental Operating Report
ML17313A95426 May 1999Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Reducing Spurious Reactor Trip Hazards Associated with Setpoints While Maintaining Plant ProtectionAnticipated operational occurrence
Fuel cladding
ML17313A83326 February 1999Re-issue of Application for Amend to Licenses NPF-41,NPF-51 & NPF-74,re TS 3.5.3,ECCS - Operating,To Extend Completion Time for One Inoperable LPSI Subsystem from 72 Hours to 7 DaysProbabilistic Risk Assessment
ML17313A83026 February 1999Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS 3.5.3, ECCS - Operating, by Extending Completion Time for One Inoperable LPSI Subsystem from 72 Hours to 7 DaysProbabilistic Risk Assessment
ML17313A70916 December 1998Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Changing Condition G of TS 3.8.1 to Ensure That Appropriate Actions Will Be Taken to Prevent Double Sequencing of safety-related LoadsSafe Shutdown
Offsite Circuit
ML17313A15717 December 1997Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Respectively.Amends Change TS 3/4.8.2 & Associated Bases 3/4.8,allowing Replacement of Existing Class 1E,125 Volt Dc Batteries W/Low Specific Gravity Cell BatteriesSafe Shutdown
ML17312B63928 August 1997Application for Amend to License NPF-51,allowing one-time Extension of Required Surveillance Interval for Msi Sys Portion Only of ESFAS Logic
ML17312B46523 May 1997Rev to 950418 Application for Amends to Licenses NPF-41, NPF-51 & NPF-74,revising TS Section 3/4.4.4, Steam Generators & Associated Bases to Allow Installation of Tube Sleeves as Alternative to Plugging Defective SG TubesNondestructive Examination
ML17312B15427 December 1996Application for Amends to Licenses NPF-41,NPF-51 & NPF-74 to Revise TS LCO 3.6.1.3.b of TS 3/4.6.1.3, Containment Air Locks, Bases 3/4.6.1.4, Internal Pressure & 3/4.6.1.6, Containment Structural Integrity.
ML17312A84328 June 1996Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Amending TS 3/4.5.2, ECCS Subsystems-Operating & Bases to Change SRs 4.5.2.d.2 & 4.5.2.d.3 to Reflect Design Basis Requirements for Anhydrous Trisodium PhosphateBoric Acid
ML17300B26317 June 1996Application for Amends to Licenses NPF-41,NPF-51 & NFP-74, Respectively,Changing Sections 1.10 & 3.2.8 & Associated Bases for Obtaining Thyroid Dcf Used in Definition of Dose Equivalent I-131Anticipated operational occurrence
ML17312A6471 April 1996Application for Amend to License NPF-51,revising TS 3/4/9.6 to Temporarily Allow Use of Hoist Instead of Refueling Machine for Movement of Fuel Assembly at Core Location A-07
ML17312A63826 March 1996Application for Amend to License NPF-51,revising TS 3/4.9.6 to Increase Refueling Machine Overload Cut Off Limit to 2,000 Lb in Effort to Free Stuck Fuel Assembly from Core Location A-06Enforcement Discretion
ML17312A63026 March 1996Application for Amend to License NPF-51,revising TS 3/4.9.6 to Relocate Refueling Machine Overload Cut Off Limit from TS 3/4.9.6 to Plant UFSAR Per Criteria in 10CFR50.36 & Rev 1 of NUREG-1432, STS for Combustion Engineering Plants.Enforcement Discretion
Probabilistic Risk Assessment
ML17312A63323 March 1996Application for Amend to License NPF-51,revising TS SR 4.8.2.1.e, DC Sources, to Suspend Provision of TS 4.0.1 & 4.0.4 for Battery Capacity Testing Requirements Until Entry Into Mode 4 Following Sixth Refueling OutageSafe Shutdown
Enforcement Discretion
ML17312A62522 March 1996Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Modifying TS 3/4.8.1 for Purposes of Implementing Recommended Changes from NUREG-1432,GL 94-01 & GL 96-05
ML17312A5419 February 1996Suppl Application for Amends to Licenses NPF-41,NPF-51 & NPF-74,implementing New Option B to 10CFR50,App J, Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors.
ML17312A5221 February 1996Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Respectively,Changing TS Sections 2.2.1 (Table 2.2-1) & 3/4.3.2 (Tables 3.3-3 & 4.3-2) to Specify Addl Restriction for Allowed Low Pressurizer Pressure Trip SetpointShutdown Margin
Anticipated operational occurrence
ML17311B31319 December 1995Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS for Implementation of 10CFR50,App J,Option B for Determining Test Frequency for Containment Leakage Rate Testing
ML17311B2657 November 1995Application for Amend to Licenses NPF-41,NPF-51 & NPF-74, Adopting Approved STS Format & Content of Section 5.0, Design Features, as Modified by Approved Changes to Improved STSOffsite Dose Calculation Manual
Fuel cladding
ML17311B0933 August 1995Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Adding Listed Analytical Method & Associated NRC SER to TS 6.9.1.10, Colr. Prorpietary PVNGS-3 Cycle 6 ECCS Performance Analysis Encl.Proprietary Analysis WithheldFuel cladding
ML17311A95013 June 1995Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS Sections 3.5.1,3.5.2,3.7.11,3/4.8.1.1 & Bases to Extend AOTs for Sit,Lpsi Subtrain & EDG & Adding Bases for Extended Aots,Consistent w/NUREG-1366 & GL 93-05
ML17311A8632 May 1995Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS 3.1.2.6,Figure 3.1-1, Min Borated Water Vols by Relocating Plant Elevations That Correspond to Min Required Water Vols for Spent Fuel Pool to Site Procedures
ML17311A75331 March 1995Application for Amends to Licenses NPF-41,NPF-51 & NPF-74. Amends Would Clarify Shutdown Margin Definition,Change shut- Down Margin Applicability & SRs to Comply W/Safety Analysis Assumptions for Subcritical Inadvertent CEA WithdrawalShutdown Margin
ML17311A56128 December 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS Sections 3.9.6 & 4.9.6.1 Re Refueling Machine Overload Cut Off Limit
ML17311A4907 December 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Requesting TS 3/4.7.5 to Change Bases for Ultimate Heat Sink from Providing 27 Day Cooling Water Supply to Providing 26 Day Cooling Water SupplyUltimate heat sink
ML17311A44830 November 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising LCO 3.2.1 & 3.2.4 & Associated Bases
ML17311A42422 November 1994Application for Amend to License NPF-41,proposing TS Section 3/4.7.1 by Adding Note to Table 3.7.2
ML17310B44912 July 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Requesting Amend to TS Table 3.3-3, ESF Actuation Sys Instrumentation.
ML17310B43417 June 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Increasing Min Nitrogen Accumulator Pressure
ML17310B40717 June 1994Application for Amend to License NPF-41,NPF-51 & NPF-74 Proposing Ts,By Removing Five Tables of Component Lists, Per GL 91-08Safe Shutdown
ML17310B2694 May 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Clarifying TS LCO 3.4.8.3 & Surveillance Requirement 4.4.2.3.1 Applicability During Steady State Conditions in RCS Heatup/Cooldown Evolutions
ML17310B16428 March 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Changing Min Condensate Storage Tank Indicated Level from 25 Ft to 29.5 Ft
ML17310B05918 February 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS Figure 3.2-1 for Units 1 & 3 & TS 3/4.1.1.4 & Bases 3/4.1.1.4 for Units 1,2 & 3 to Allow Units 1 & 3 to Operate at 100% Full Power Under Reduced Temp Regimen
ML17310A8864 January 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74 Modifying Ts,Implementing Recommended Changes from GL 93-05, Line -Item TS Improvements to Reduce SR for Testing During Power Operation.
ML17310A8894 January 1994Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Proposing Changes to TS Section 3/4.2.3, Azimuthal Power Tilt, & Bases,Requesting Toprovide More Restrictive Azimuthal Power Tilt Limit When COLSS Out of Svc
ML17310A88230 December 1993Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Changing TS Section 3/4.3.2 by Modifying Tables 3.3-4,3.3-5 & Adding Figure 3.3-1
ML17310A8492 December 1993Application for Amends to Licenses NPF-41,NPF-51 & NPF-74 Modifying TS by Removing Schedular Requirements for Type a Test to Be Performed Specifically at 40 + or - 10 Month Intervals
ML17310A7875 November 1993Application for Amend to License NPF-51,revising LCOs 3.5.2, ECCS, 3.6.2-1, CSS, 3.7.1.2, Afs, 3.7.3, EWS, 3.7.6, Ecw Sys & 3.7.11, Sdcs Under Exigent CircumstancesEnforcement Discretion
Probabilistic Risk Assessment
ML17310A72527 October 1993Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS Section 1.18,6.9.1.8,6.14.c & 6.15.1 in Order to Implement Revised 10CFR50.36a Regulation That Now Allows Radioactive Effluent Release Rept to Be Submitted AnnuallyAnnual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
ML17310A6138 September 1993Application for Amend to License NPF-41,requesting TS Section 6.9.1.10 to Add Analytical Method Suppl Entitled Sys 80 Inlet Flow Distribution to List of Methods Used to Determine Core Operating Limits
ML17310A5185 August 1993Application for Amends to Licenses NPF-41,NPF-51 & NPF-65, Requesting Change to Word Pressurizer to RCS for Item 4 in Tables 3.3-10 & 4.3-7
ML17310A41830 June 1993Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS 3/4.3.2 to Request Addl Operating Margin in Time Response of Turbine Driven AF Pump to SG Low Level SignalProbabilistic Risk Assessment
Temporary Modification
ML17306B19828 December 1992Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Respectively,Revising TS 3/4.3.1,Table 4.3-1 & 3/4.3.2,Table 4.3-2,to Change Surveillance Requirements from Monthly to Quarterly for Several Channel Functional TestsAnticipated operational occurrence
Probabilistic Risk Assessment
ML17306A68927 April 1992Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Amending Tech Spec 3/5.7.6 & Bases of Section 3/4.7.6 to Reduce Essential Chilled Water Sys out-of-svc Time from 7 Days to 72 H
ML17306A60920 March 1992Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS Section 3/4.9.9 to Change Containment Purge Valve Isolation Sys Operability Requirements for Consistency W/Other Containment Penetration Operability Requirements
ML17306A37630 December 1991Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Revising TS Section 3.6.1.7 Action Statements Re Containment Purge Supply & Exhaust Valves for Consistency W/Other Containment Sys Action Requirements
ML17306A35420 December 1991Application for Amend to License NPF-74,adding Sentence to TS Section 5.3.1 to Allow Substitution of Up to Total of 80 Fuel Rods Clad W/Advanced zirconium-based Alloys Other than Zircaloy-4 in Two Fuel Assemblies.Rept WithheldAnticipated operational occurrence
Exemption Request
Fuel cladding
ML17305B7309 September 1991Application for Amends to Licenses NPF-41,NPF-51 & NPF-74, Changing Tech Spec 3/4.7.11, Shutdown Cooling Sys to Delete auto-closure Interlock Surveillance of Surveillance Requirement 4.7.11b,per Generic Ltr 88-17Stroke time
ML17305B71628 August 1991Application for Amends to Licenses NPF-41,NPF-51 & NPF-74. Proposed Amends Resolve Inconsistent Application of Exceptions to Tech Spec 3.0.4 & Specify Acceptable Time Limit for Completing Missed SurveillanceMissed surveillance