I RIC)RI EY

,ACCELERATED RIDS PROCESSIi~

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9412050368 DOC.DATE: 94/11/30 NOTARIZED: NO DOCKET FACIL:STN-50-528 Palo Verde Nuclear Station, Unit 1, Arizona Publi 05000528 STN-50-529 Palo Verde Nuclear Station, Unit 2, Arizona Publi 05000529 STN-50-530 Palo Verde Nuclear Station, Unit 3, Arizona Publi 05000530 AUTH.NAME AUTHOR AFFILIATION STEWART,W.L.

Arizona Public Service Co.

(formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Application for amends to licenses NPF-41,NPF-51 6 NPF-74 to TS re revised marked-up TS pages for proposed amend to TS LCO 3.2.1,3.2.4 6 associated bases.

DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTR I ENCL L SIEE: &I TITLE: OR Submittal:

General Distribution NOTES:STANDARDIZED PLANT Standardized plant.

Standardized plant.

05000528 05000529 05000530 RECIPIENT ID CODE/NAME PD4-2 LA HOLIAN, B INTERNAL: ACRS NRR/DE/EELB NRR/DRPW NRR/DSSA/SRXB OGC/HDS2 EXTERNAL: NOAC COPIES LTTR ENCL 1

1 1

1 6

1 1

1 1

1 1

1 0

1 1

RECIPIENT ID CODE/NAME PD4-2 PD TRAN,L

'F LE CENTER~0 1 RR/DRCH/HICB NRR/DSSA/SPLB NUDOCS-ABSTRACT NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 Y'OTE TO ALL"RIDS" RECIPIEY'TS:

PLEASE HELP US TO REDUCE O'ASTE! COYTACT'IHE DOCL'WIEYTCOYTROL DESK, ROON! PI-37 (EXT. 504-0083 ) TO ELIXfliKTE YOL'R N'Ai!LPROil DISTRIBUTIONLIS'I'S I'OR DOCL MEi'I'SYOL'OY."I'lI'.D!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 20 ENCL 19

2 I

1 I

I

Arizona Public Service Company P.O. BOX 53999

~

PHOENIX. ARIZONA85072<999 10 CFR 50.90 WILLIAML. STEWART EXECUTIVEVICEPRESIDENT NVCI.EAR 102-03199-WLS/SAB/NLT November 30, 1994 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-37 Washington, DC 20555

References:

1.

Letter 102-02352, dated November 20, 1992, "Proposed Amendment to Technical Specification Limiting Condition for Operation 3.2.1, 3.2.4, and the Associated Bases,"

from W. F. Conway, APS, to USNRC 2.

Letter 102-02700, dated October 22, 1993, "APS Response to NRC Questions on the Proposed Amendment to Technical Specification Limiting Condition for Operation 3.2.1, 3.2.4, and the Associated Bases," from W. F. Conway, APS, to USNRC

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2, and 3 Docket Nos. STN 50-528/529/530 Revised Marked-Up Technical Specification Pages for the Proposed Amendment to LimitingCondition for Operation 3.2.1, 3.2.4, and the Associated Bases File: 94-005-41 9.05 94-056-026 The enclosure to this letter provides revised marked-up Technical Specification (TS) pages for the proposed amendment to TS Limiting Condition for Operation (LCO) 3.2.1, 3.2.4, and the associated bases, previously submitted to the NRC in Reference 1.

The revised pages incorporate the requirement to monitor Linear Heat Rate (LHR) and Departure from Nucleate Boiling Ratio (DNBR) using the Core Protection Calculators (CPCs), while the Core Operating Limit Supervisory System (COLSS) is out of service, into the action statement of the subject LCOs.

These revised TS pages provide clarification of the requirement by including it in the action statement and do not constitute an intent change.

The Reference 1 submittal included this requirement in the bases section ofthe subject TSs in accordance with the Combustion Engineering Owners Group Standard Technical Specifications (CEOG STS) published in NUREG 1432.

Subsequently, the NRC informed Arizona Public Service Company (APS) that it is appropriate to include this requirement in the action statement ofthe subject LCOs, since 0503+~ 94il30 t,'>

PDR ADOCK 05000528 PDR

'i

U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Revised TS Pages for Amendment to TS LCO 3.2.1, 3.2.4, and Associated Bases Page 2 the basis for the increase in allowed out-of-service time is, in part, due to the monitoring with the CPCs.

The NRC has indicated that the GEOG STS willbe changed in the future.

The NRC also requested that APS add 2 additional paragraphs from the GEOG STS to the associated sections of the PVNGS TS bases.

The information contained in the

~

additional paragraphs is similar to that provided in the previously submitted marked-up bases pages and the safety analysis and no significant hazards consideration provided in the Reference 1 submittal. APS has revised the marked-up bases pages in response to the NRC request.

In the Reference 2 response to NRC Question P2, APS described the procedure changes that would be implemented due to the proposed TS amendment request.

The specific steps and verbiage will be finalized and implemented upon approval of the TS amendment request during the procedure change process.

Please note that

Response

B.5 to NRC Question 42, which discussed the Surveillance Requirements (SR) performed when operating within the COLSS out-of-service limits, incorrectly referenced TS SR 4.3.2.1.

The correct SRs, which will be performed for LHR and DNBR when COLSS is out of service, are TS SR 4.2.1.2 and 4.2.4.2, respectively.

Pursuant to 10 CFR 50.91(b)(1), a copy of this document is being forwarded to the Arizona Radiation Regulatory Agency.

Should you have any questions, please contact Scott A. Bauer at (602) '393-5978.

Sincerely, WLS/SAB/NLT/rv Enclosure cc:

L. J. Callan K. E. Perkins B. E. Holian K. E. Johnston A; V. Godwin (ARRA)