Site | Start date | Title | Topic | |
---|---|---|---|---|
05000271/FIN-2014005-01 | Vermont Yankee | 31 December 2014 23:59:59 | Compensatory Continuous Fire Watches Not Implemented as Required | Safe Shutdown Significance Determination Process Continuous fire watch Fire Protection Program Fire Watch |
05000271/FIN-2014005-03 | Vermont Yankee | 31 December 2014 23:59:59 | Failure to Follow Procedure Results in Inoperable Emergency Diesel Generator | Safe Shutdown High winds Significance Determination Process Large early release frequency |
05000271/FIN-2014005-02 | Vermont Yankee | 31 December 2014 23:59:59 | Misclassification of Emergency Conditions Based on Radiological Criteria | Significance Determination Process |
05000271/FIN-2014004-01 | Vermont Yankee | 30 September 2014 23:59:59 | Failures to Promptly Identify Through-Wall Leakage from Service Water Piping to the Emergency Diesel Generators | Significance Determination Process Through-Wall Leak |
05000271/FIN-2014004-02 | Vermont Yankee | 30 September 2014 23:59:59 | Failure to Submit Reactor Building Crane Digital Control System Modification for Approval | Significance Determination Process Fuel cladding |
05000271/FIN-2014004-03 | Vermont Yankee | 30 September 2014 23:59:59 | Failure to Follow Procedure Results in Inoperable Containment Isolation Valve | Stroke time Significance Determination Process |
05000271/FIN-2014004-04 | Vermont Yankee | 30 September 2014 23:59:59 | Licensee-Identified Violation | Significance Determination Process |
05000271/FIN-2014007-01 | Vermont Yankee | 30 June 2014 23:59:59 | Inadequate Design Control of SBO Loading Calculation | |
05000271/FIN-2014403-02 | Vermont Yankee | 30 June 2014 23:59:59 | Security | |
05000271/FIN-2014403-01 | Vermont Yankee | 30 June 2014 23:59:59 | Security | |
05000271/FIN-2014002-01 | Vermont Yankee | 31 March 2014 23:59:59 | Failure to Monitor the Unavailability of the Fire Water to Service Water Crosstie | Significance Determination Process |
05000271/FIN-2013005-01 | Vermont Yankee | 31 December 2013 23:59:59 | Inadequate Corrective Actions to Restore Switchgear Room Flood Boundary | Significance Determination Process |
05000271/FIN-2013005-02 | Vermont Yankee | 31 December 2013 23:59:59 | Inadequate Risk Assessment for Isolating All Nitrogen Supply to the Containment Instrument Air System | Significance Determination Process Incremental Core Damage Probability Deficit |
05000271/FIN-2013004-01 | Vermont Yankee | 30 September 2013 23:59:59 | Failure to Monitor the Unavailability of the B Control Rod Drive Equipment Train | Significance Determination Process Maintenance Rule Program |
05000271/FIN-2013004-02 | Vermont Yankee | 30 September 2013 23:59:59 | Failure to Maintain Radiation Exposure ALARA During Refueling Activities | Significance Determination Process |
05000271/FIN-2013004-03 | Vermont Yankee | 30 September 2013 23:59:59 | Operator Error Results in Diesel Generator Overload | Significance Determination Process |
05000271/FIN-2013003-01 | Vermont Yankee | 30 June 2013 23:59:59 | Inadequate Corrective Actions for Sealing Flood Pathways into the Electrical Switchgear Rooms | Significance Determination Process |
05000271/FIN-2013003-02 | Vermont Yankee | 30 June 2013 23:59:59 | Failure to Maintain Compensatory Measures Required for a Barrier Breach Permit for the A Emergency Diesel Generator Room | Significance Determination Process |
05000271/FIN-2013003-03 | Vermont Yankee | 30 June 2013 23:59:59 | Inadequate Procedure for Configuration Control Results in a Dislodged Secondary Containment Blowout Panel Due to Reactor Building Ventilation System Pressurization | Significance Determination Process |
05000271/FIN-2013008-01 | Vermont Yankee | 30 June 2013 23:59:59 | Improper Maintenance Rule Scoping of the Reactor Building HVAC System | Maintenance Rule Program |
05000271/FIN-2013202-01 | Vermont Yankee | 30 June 2013 23:59:59 | Security | |
05000271/FIN-2013002-01 | Vermont Yankee | 31 March 2013 23:59:59 | Appendix R Fire Door Not Latching Closed Due to Misalignment | Fire Barrier Significance Determination Process Fire Protection Program Hourly Fire Watch |
05000271/FIN-2013002-02 | Vermont Yankee | 31 March 2013 23:59:59 | Failure to Implement Compensatory Measures Associated with a Temporary Modification | Temporary Modification Significance Determination Process |
05000271/FIN-2013002-04 | Vermont Yankee | 31 March 2013 23:59:59 | Failure of the B Emergency Diesel Generator from Jacket Water Leakage Due to Inadequate Corrective Action | Significance Determination Process |
05000271/FIN-2013002-03 | Vermont Yankee | 31 March 2013 23:59:59 | Inadequate Corrective Action for Maintaining Operability of the LOW Pressure Coolant Injection Battery UPS-1A | Significance Determination Process |
05000271/FIN-2012005-01 | Vermont Yankee | 31 December 2012 23:59:59 | Failure of the B Emergency Diesel Generator from Jacket Water Leakage Due to Inadequate Corrective Action | |
05000271/FIN-2012005-02 | Vermont Yankee | 31 December 2012 23:59:59 | Licensee-Identified Violation | |
05000271/FIN-2012004-02 | Vermont Yankee | 30 September 2012 23:59:59 | Dedicated Operators Required for Operability Under Applied Administrative Controls Left Immediate Vicinity of Open Valves | Significance Determination Process Fuel cladding |
05000271/FIN-2012004-01 | Vermont Yankee | 30 September 2012 23:59:59 | Incorrect Assessment of Equipment Condition Resulted in Single Recirculating LOOP Operation | Arc flash Significance Determination Process |
05000271/FIN-2012003-02 | Vermont Yankee | 30 June 2012 23:59:59 | Inadequate Risk Assessment Due to Not Considering the Increased Risk of a Plant Transient When Securing a Feedwater Pump | Significance Determination Process Incremental Core Damage Probability Deficit |
05000271/FIN-2012003-01 | Vermont Yankee | 30 June 2012 23:59:59 | Inadequate Risk Assessment for Isolating the Condensate Pumps\' Minimum Flow Line\'S Automatic Flow Control Valve | Significance Determination Process Incremental Core Damage Probability Deficit |
05000271/FIN-2012002-02 | Vermont Yankee | 31 March 2012 23:59:59 | Failure to the D Service Water Pump Due to LOW Oil and Inadequate Corrective Actions | |
05000271/FIN-2012002-01 | Vermont Yankee | 31 March 2012 23:59:59 | Failure of the B UPS Techometer Coupling Due to Age and Inadequate Corrective Actions | |
05000271/FIN-2011005-03 | Vermont Yankee | 31 December 2011 23:59:59 | Incomplete Inventory for Spent Resin Shipment | Significance Determination Process |
05000271/FIN-2011005-01 | Vermont Yankee | 31 December 2011 23:59:59 | Inadvertent Trip of the \\\"A\\\" Emergency Diesel Generator Fuel Rack | |
05000271/FIN-2011005-02 | Vermont Yankee | 31 December 2011 23:59:59 | Loss of Shutdown Cooling due to Tag-Out Error | |
05000271/FIN-2011404-01 | Vermont Yankee | 30 June 2011 23:59:59 | Security | |
05000271/FIN-2011403-01 | Vermont Yankee | 31 March 2011 23:59:59 | Security | |
05000271/FIN-2011002-05 | Vermont Yankee | 31 March 2011 23:59:59 | None | Significance Determination Process Incremental Core Damage Probability Deficit |
05000271/FIN-2011002-04 | Vermont Yankee | 31 March 2011 23:59:59 | None | |
05000271/FIN-2011002-03 | Vermont Yankee | 31 March 2011 23:59:59 | None | |
05000271/FIN-2011002-02 | Vermont Yankee | 31 March 2011 23:59:59 | Steam Leak on High Pressure Coolant Injection (HPCI) During Surveillance Testing | Significance Determination Process |
05000271/FIN-2011002-01 | Vermont Yankee | 31 March 2011 23:59:59 | Failure to Follow Foreign Material Exclusion Procedure | Foreign Material Exclusion |
05000271/FIN-2010403-01 | Vermont Yankee | 31 March 2011 23:59:59 | Security | |
05000271/FIN-2010005-03 | Vermont Yankee | 31 December 2010 23:59:59 | Licensee-Identified Violation | |
05000271/FIN-2010008-01 | Vermont Yankee | 31 December 2010 23:59:59 | Fire Scenario Resulting in Loss of Reactor Core Isolation Cooling System | Reactor Vessel Water Level Significance Determination Process Fire Protection Program |
05000271/FIN-2010005-01 | Vermont Yankee | 31 December 2010 23:59:59 | Failure to Perform Required Quality Control Inspections | |
05000271/FIN-2010005-02 | Vermont Yankee | 31 December 2010 23:59:59 | Failure to Implement the Experience and Qualification Requirements of the Quality Assurance Program | Significance Determination Process |
05000271/FIN-2010004-01 | Vermont Yankee | 30 September 2010 23:59:59 | Inadvertent isolation of Reactor Core Isolation Cooling (RCIC) During Surveillance Testing | |
05000271/FIN-2010003-01 | Vermont Yankee | 30 June 2010 23:59:59 | Inadvertent Loss of RCS Inventory During ECCS Testing Due to Inadequate Procedure |