Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML21334A02522 November 20213 to Updated Final Safety Analysis Report, Chapter 16, Managing the Effects of Component AgingBoric Acid
Non-Destructive Examination
Fire Barrier
Coatings
Operating Basis Earthquake
Nondestructive Examination
Incorporated by reference
Aging Management
Pressure and Temperature Limits Report
Design basis earthquake
Flow Accelerated Corrosion
Stress corrosion cracking
Eddy Current Testing
License Renewal
Earthquake
Control of Heavy Loads
Biofouling
Fire Protection Program
Power Uprate
Thermography
ML20160A07520 May 20202 to Updated Final Safety Analysis Report, Chapter 16, Managing the Effects of Component AgingBoric Acid
Non-Destructive Examination
Fire Barrier
Coatings
Operating Basis Earthquake
Nondestructive Examination
Incorporated by reference
Aging Management
Pressure and Temperature Limits Report
Design basis earthquake
Flow Accelerated Corrosion
Stress corrosion cracking
Eddy Current Testing
License Renewal
Earthquake
Control of Heavy Loads
Biofouling
Fire Protection Program
Power Uprate
Thermography
ML14030A13527 January 2014WCAP-17790-NP, Revision 1, PWR Vessel Internals Program Plan for Aging Management of Reactor Internals.Nondestructive Examination
Functionality Assessment
Aging Management
Stress corrosion cracking
License Renewal
EVT-1
Liquid penetrant
Power Uprate
ML14030A13427 January 2014WCAP-17789-NP, Rev. 1, PWR Vessel Internals Program Plan for Aging Management of Reactor Internals.Nondestructive Examination
Functionality Assessment
Aging Management
Stress corrosion cracking
License Renewal
EVT-1
Liquid penetrant
Power Uprate
ML09300027831 October 2009NUREG-1929, Vol. 2, Safety Evaluation Report Related to the License Renewal of Beaver Valley Power Station, Units 1 and 2.Unanalyzed Condition
Boric Acid
Non-Destructive Examination
Fire Barrier
Anticipated operational occurrence
Safe Shutdown Earthquake
Weld Overlay
Hydrostatic
Coatings
Nondestructive Examination
Incorporated by reference
High Energy Line Break
Aging Management
Pressure and Temperature Limits Report
Design basis earthquake
Intergranular Stress Corrosion Cracking
Stress corrosion cracking
Integrated leak rate test
License Renewal
Earthquake
Control of Heavy Loads
Fire Protection Program
Dissimilar Metal Weld
Power Uprate
ML09070025524 March 2009Relief Request No. 1 - TYP-3-IWB-2412 Regarding the Third 10-Year Interval Inservice Inspection PlanIncorporated by reference
License Renewal
L-08-207, Proposed Alternative to American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section XI Inspection Period Extension Requirement24 September 2008Proposed Alternative to American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section XI Inspection Period Extension RequirementLicense Renewal
L-08-147, Reply to Request for Additional Information for Renewal License Application2 June 2008Reply to Request for Additional Information for Renewal License ApplicationSafe Shutdown Earthquake
Weld Overlay
Aging Management
Stress corrosion cracking
License Renewal
DM weld
Power Uprate
ML08025006021 January 2008Eighteenth Refueling Outage Inservice Inspection ReportWeld Overlay
Hydrostatic
VT-2
Dissimilar Metal Weld
ML0625801202 October 2006(BVPS-1 and 2), Inservice Inspection (ISI) Program, Alternative Examination of Reactor Coolant Pipe Welds, Request for Relief No. BV3-RV-2Dissimilar Metal Weld
L-05-078, Responses to a Request for Additional Information in Support of License Amendment Request Nos. 302 and 17326 May 2005Responses to a Request for Additional Information in Support of License Amendment Request Nos. 302 and 173Safe Shutdown
Non-Destructive Examination
Fire Barrier
Stroke time
Coatings
Aging Management
Pressure and Temperature Limits Report
Design basis earthquake
Flow Accelerated Corrosion
Feedwater Heater
Stress corrosion cracking
Severe Accident Management Guideline
License Renewal
Earthquake
Power-Operated Valves
Fire Protection Program
Flow Induced Vibration
Power Uprate
Measurement Uncertainty Recapture
Affidavit
Manual Operator Action
Negative Flux Rate Trip
Water hammer
ML0311405497 November 1991Withdrawn NRC Generic Letter 1991-018: Information to Licensees Regarding Two NRC Inspection Manual Sections on Resolution of Degraded and Nonconforming Conditions and on OperabilitySafe Shutdown
Unanalyzed Condition
Fitness for Duty
Probabilistic Risk Assessment
Condition Adverse to Quality
Missed surveillance
Operability Determination
Exemption Request
Pressure Boundary Leakage
Backfit
Operational leakage