Exelon Generation Company, LLC www.exeloncorp.com Exel no Quad Cities Nuclear Power Station Nuclear 22710 2o6th Avenue North Cordova, IL 61242-9740 10CFR50.55a SVP-1 1-069 September 7, 2011 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Quad Cities Nuclear Power Station Unit 1 Renewed Facility Operating License No. DPR-29 NRC Docket No. 50-254

Subject:

Unit 1 Post Outage Inservice Inspection (ISI) Summary Report Enclosed is the Quad Cities Nuclear Power Station Unit 1 Post-Outage Summary Report for Inservice Inspection examinations and Repair/Replacement activities conducted from the end of the May 2009 refueling outage through the May 2011 refueling outage. This report is due within 90 days after the end of the Unit 1 May 2011 refueling outage, which is September 8, 2011. This report documents examinations performed during the third period of the fourth inspection interval.

This report is submitted in accordance with the requirements of ASME Section Xl, Article IWA-6200, "Requirements."

If there are any questions or comments concerning this letter, please refer them to Mr. Wally Beck, Regulatory Assurance Manager, at (309) 227-2800.

Sincerely, Tim Hanley Site Vice President Quad Cities Nuclear Power Station

Attachment:

Quad Cities Nuclear Power Station - Unit 1 Post Outage (90 Day) Summary Report cc: Regional Administrator - NRC Region III NRC Senior Resident Inspector - Quad Cities Nuclear Power Station

ATTACHMENT Quad Cities Nuclear Power Station-Unit 1 Post Outage (90 Day) Summary Report

Quad Cities Nuclear Power Station - Unit 1 Post Outage (90 Day) Summary Report Refueling Outage Q 1R21 Outage Start Date: May 9, 2011 Outage End Date: June 10, 2011 Commercial Service Date: February 18, 1973 22710 2 0 6th Avenue North, Cordova, IL 61242 Exelon Generation Company, L.L.C.

300 Exelon Way Kennett Square, PA 19348 Prepared by:

Mathew Rice (ISI Engineer)

Reviewed by:

Seel (Reactor Internals Engineer)

Reviewed by:

6 Gary KnappO(Sr ber Engineer)

Reviewed by:

Dafid Kunzmann (Pressure Test Engineer)

Reviewed by:

Brian Hulinepair/Replacement Engineer)

Approved by:

V om Wojcik (Manager Program Engineering)

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit I1 Kennett Square, PA 19348 22710 20 6th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table of Contents

1.0 INTRODUCTION

........................................................................................................................................... 3..3 1.1. OUTAGE, PERIOD AND INTERVAL START AND END DATES ....................................................................... 3 1.2. EXAM INATION PROGRAM REQUIREMENTS ........................................................................................... 3 2.0 NIS-1 FORM ....................................................................................................................................................... 4 3.0 ABSTRACT OF EXAMINATIONS, CONDITIONS NOTED AND CORRECTIVE MEASURES .......... 6 3.1. SECTION XI EXAMINATIONS

SUMMARY

............................................................................................... 6 3.2. BWRVIP-75/GENERIc LETTER 88-01 ..................................................................... ................. 7 3.3. INVESSEL INSPECTIONS (IVI) .................................................. ............ .................... 7 Table 3.1-1 Quad Cities Unit I ASME Section XI Outage Summary........................................... 9 Table 3.1-lA Follow Up Exams in Accordance with IWF-2200(b)................................................. 11 Table 3. I-lB Quad Cities Unit I - ASME Section XI Limited Coverage Summary (4h Interval).......... 11 Table 3.1-2 Quad Cities Unit 1 PressureTesting Summary ............................... .................... 12 Table 3.1-3 Quad Cities Unit I Snubber FunctionalTests ................................ ..................... 13 Table 3.1-4 Quad Cities Unit I Conditions Noted During ISI on ASME Code Components and CorrectiveActions

........................ 14 Table 3.2-1 Quad Cities Unit I BWRVIP-75-A/GL 88-01 Outage Summary.............................. 15 Table 3.3 Number and Percentageof Examinations Completed........................................... 16 4.0 REPAIR / REPLACEMENT

SUMMARY

................................................................................................ 17 4.1. N IS -2 INDEX........................................................................................................................................... 17 T ab le 4 .1-1 ............................................................................................................................................ 17 4.2 . N IS -2 FORMS.......................................................................................................................................... 19 2 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206'h Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 1.0 Introduction 1.1. Outage, Period and Interval Start and End Dates This Inservice Inspection Summary Report encompasses examinations and repairs performed from May 25, 2009 through June 10, 2011 during the fourth ten-year interval third inspection period. This most recent refueling outage was the 2 1 st refueling outage for Quad Cities Nuclear Power Station Unit 1 and is the first outage for this unit during the third inspection period. The outage started May 9, 2011 and was completed June 10, 2011 when the unit returned to service.

Tests, examinations, and repair/replacement activities associated with American Society of Mechanical Engineers (ASME) Code,Section XI were witnessed or otherwise verified by the Authorized Nuclear Inservice Inspectors. Non-ASME Section XI or augmented examinations were not witnessed or otherwise verified by the Authorized Nuclear Inservice Inspectors and are marked "Not Required" or "N/A" on the applicable examination reports.

The Authorized Nuclear Inservice Inspectors are inspectors of the Hartford Steam Boiler Inspection & Insurance Company of Connecticut (HSB-CT). The HSB-CT Regional Office is located at 2443 Warrenville Road Suite 500, Lisle, Illinois, 60532-1098.

1.2. Examination Program Requirements The examination requirements of ASME Boiler and Pressure Vessel Code,Section XI, Division 1, "Rules for Inservice Inspection of Nuclear Power Plant Components", 1995 Edition through 1996 Addenda were implemented for Class 1, 2 and 3 components except where written relief has been granted by the NRC. Written relief, in the form of Relief Request 14R-02 approving Risk Informed Inservice Inspection (RI-ISI) as an inspection program alternative for Code Categories B-F, B-J, C-F-1 and C-F-2, was utilized during Q1R21. The ultrasonic examination volumes for RI-ISI components were increased from the Section XI requirements to meet the RI-ISI Program.

The ultrasonic examination requirements of ASME Boiler and Pressure Vessel Code,Section XI, Appendix VIII, 1995 Edition with Addenda through 1996, as required by 10 CFR 50.55a, "Codes and Standards", and amended by the Federal Register Notice 64 FR 51370 dated September 22, 1999 is executed through the Performance Demonstration Initiative (PDI) Program according to the schedule defined in 10 CFR 50.55a(g)(6)(ii)(C),

for wrought austenitic piping welds, ferritic piping welds, bolts/studs, reactor vessel welds, nozzle to vessel welds, nozzle inside radius sections and full structural overlaid wrought austenitic piping welds.

3 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 2.0 NIS-1 Form FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner Exelon Generation Company, L.L.C., 300 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner)
2. Plant Quad Cities Nuclear Power Station, 22710 206"'h Avenue North, Cordova, IL 61242 (Name and Address of Plant)
3. Plant Unit One 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 2/18/73 6. National Board Number for Unit N/A
7. Components Inspected Component or Manufacturer Manufacturer State or National Appurtenance Or Installer or Installer Province No. Board No.

Serial No.

Reactor Pressure Chicago Bridge & Iron T-22 B0075000 N/A Vessel Reactor Recirculation Dravo Corp. N/A - See Table 3.1-1 N/A N/A Core Spray Grinnell N/A - See Table 3.1-1 N/A N/A Feedwater Grinnell N/A - See Table 3.1-1 N/A N/A Main Steam Grinnell N/A - See Table 3.1-1 N/A N/A Residual Heat Grinnell N/A - See Table 3.1-1 N/A N/A Removal Control Rod Drive Grinnell N/A - See Table 3.1-1 N/A N/A High Pressure Coolant Grinnell N/A - See Table 3.1-1 N/A N/A Injection Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/22 in. x 111/22 in.,

(2) information in items 1 through 6 on this report is included on each sheet unless they are coded N/A, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

4 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 FORM NIS-1 (Back)

8. Examination Dates: 3/1/10 to 6/10/11
9. Inspection Period Identification: Yrd Period - From 3/ 1/10 to 4/1/13 for the 4h Interval
10. Inspection Interval Identification: 4th Interval - From 3/10/03 to 4/1/13
11. Applicable Edition of Section XI 1995 Addenda 1996
12. Date/Revision of Inspection Plan: 12/3/10 Revision 7 ( 4 th Interval)
13. Abstract of Examination and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Section 3.0 and Tables 3.1-1, 3.1-4A, 3.1-11B, 3.1-2, 3.1-3, 3.1-4, 3.2-1, and 3.3.
14. Abstract of Results of Examinations and Tests. See Section 3.0 and Tables 3.1-1 3.1-4A, 3.1- lB, 3.1-2, 3.1-3, 3.1-4, 3.2-1, and 3.3
15. Abstract of Corrective Measures. See Section 3.0 and Table 3.1-4.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date 20 I1 Signed Exelon Corporation By Owner CERTIFICATE OF INSERVICE INSPECTION I, the under signed, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois, and employed by Hartford Steam Boiler of Connecticut of Hartford, Connecticut have inspected the components described in the Owner's Report during the period 3/1/10 To 6/10/11 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

i<22" Inspector's Signature Commissions /t"BtJL-3SA1I t- 7--11 National Board, State, Province, and Endorsements Date 1-7 Au(- 20 p 5 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit I Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 3.0 Abstract of Examinations, Conditions Noted and Corrective Measures 3.1. Section XI Examinations Summary A combination of ultrasonic (UT), liquid penetrant (PT), magnetic particle (MT) and visual (VT) testing were performed prior to and during the 2 1st refueling outage on ISI Program components. Examinations were performed by General Electric (GE) and Exelon Nuclear personnel. Volumetric and surface examinations were compared with the recorded results of previous examinations for applicable Class 1, 2 and RI-ISI components. ISI inspections comprised of 44 volumetric (21 were RI-ISI, Category R-A welds), 10 surface examinations and 44 visual examinations were performed on Class 1, 2 and RI-ISI components. One of the visual exams was a subsequent exam due to IWF-2420(b) for corrective action from the Second Period. There were 4 volumetric examinations that did not meet coverage requirements of ASME Section XI Code (i.e. greater than 90 percent of the specified examination volume) during Q1R21 (Table 3.1-1B). Code cases used for ISI or Repair/Replacement activities are listed in the ISI Program Plan.

Pressure testing VT-2 examinations not related to repair/replacement activities are documented in Table 3.1-2, "Quad Cities Unit 1 Pressure Testing Summary". The Class 1 and 2 System Leakage Tests were performed in accordance with the 1995 Edition 1996 Addenda of the ASME Code and applicable Relief Requests as listed in Table 3.1-2 for the third period of the fourth Interval.

Exelon personnel performed functional tests on a total of twenty-seven (27) snubbers for operability per the Service Life Monitoring/Failure Trending Sample and ASME OM Code Subsection ISTD. Thirteen (13) snubbers were selected for the 10% sample group testing with the remaining fourteen (14) being tested for Service Life Monitoring. Nineteen (19) of the twenty-seven (27) snubbers were ASME Section XI Code designated. In addition, twenty-seven (27) replacement snubbers were tested and installed in accordance with a planned snubber replacement plan which is part of the Service Life Monitoring strategy. Of the fifty-four (54) snubbers tested, one (1) Mechanical snubber and one (1) hydraulic snubber that were removed from the plant for Service Life Monitoring testing were found to be unacceptable for continued operation. The failures were reviewed and no sample expansions were required. The failed hydraulic snubber was replaced with a like for like unit and the failed mechanical was replaced with a hydraulic snubber that is more robust to the conditions experienced at the installation location. Snubber testing activities are summarized in Table 3.1-3, "Quad Cities Unit 1 Snubber Functional Tests.

Table 3.1-4 "Quad Cities Unit 1 Conditions Noted on ASME Code Components and Corrective Actions" summarizes the conditions noted during the examinations and corrective measures taken prior to returning the unit to service.

Table 3.3 identifies number and percentage of examinations completed in the fourth interval.

6 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206t' Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 3.2. BWRVIP-75-A/Generic Letter 88-01 Augmented examinations required by Generic Letter 88-01, "NRC Position on Intergranular Stress Corrosion Cracking (IGSCC) in BWR Austentic Stainless Steel Piping" and BWRVIP-75-A, "BWR Vessel and Internals Project Technical Bases for Revisions to Generic Letter 88-01 Inspection Schedules", were implemented in this outage (Table 3.2-1).

Thirteen Category C Welds (susceptible to IGSCC but mitigated by stress improvement) were examined. Three Category E Welds (cracked weldments that have been mitigated by a weld overlay) were examined. Two of these welds (02AD-F12 and 02BS-F4) were overlaid in Q1R18 and received their subsequent examination in accordance with B WRVIP-75-A.

All welds had no relevant indications. This is consistent with previous examination results.

3.3. In-Vessel Inspections (IVI)

Relief Request 14R-15 was approved as an alternative to Category B-N-1 and B-N-2 requirements. Attachment Weld Exams performed under BWRVIP-48-A during Q1R21 included:

" Visual inspections of the Steam Dryer wall support lugs in accordance with BWRVIP A (EVT-1, VT-3)

" Visual inspections of Jet Pump (JP) 4 RB-la Primary Riser Brace Leaf to Vessel Pad (EVT- 1)

  • Moisture Separator Guide Rod Support Bracket Attachment Upper Weld at 200 Degrees (EVT-1, VT-1, VT-3)

Augmented examinations were performed to implement additional BWRVIP requirements in accordance with the guidelines listed:

  • Visual inspections of Jet Pump Assemblies in accordance with BWRVIP-41 Revision 2
  • Visual inspections of Jet Pump riser welds in response to Laguna Verde operating experience supplemental guidance per BWRVIP Letter 2009-202
  • Visual inspections of Core Spray piping welds and spargers in accordance with BWRVIP-18 Revision 1
  • Visual inspections of Core Shroud Vertical welds in accordance with BWRV1P-76-A, EVT-1
  • Visual inspections of Core Shroud Horizontal welds H8 and H9 in accordance with BWRVIP-76-A, EVT- 1
  • Visual inspections of the Steam Dryer in accordance with GE recommendations and guidance provided in BWRVIP-139
  • Visual inspections of the Access Hole Covers in accordance with BWRVIP-180, VT-i.
  • Visual inspections of the Jet Pump Riser RS-2 welds on all 10 risers in accordance with BWRVIP-41 Revision 2.
  • UT inspections of eight Jet Pump Hold down Beams in accordance with BWRVIP-41 Revision 2
  • Visual inspections of Core Shroud support structure welds in accordance with BWRVIP-38 7 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206h Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 All eight Feedwater Sparger End Bracket pins were inspected during QIR21 as a follow-up to minor bracket wear from the pins identified during previous outages. The pinheads are wearing into the bracket hardware due to flow-induced vibration. This is not a concern for the immediate future since the brackets still have greater than 90% of original thickness remaining. No new or additional wear was noted in Q1R21. However, an indication was identified in the 206 degree Feedwater Sparger End Bracket Pin nut tack weld. These indications are documented in IR 1218182 and EC 384463.

Core Spray piping welds were examined (34 visual exams and 39 UT exams). In this population were 8 welds with previously identified indications. Each of these indications was examined in Q1R21 with no significant change in size. No additional indications were identified in the rest of the population. These indications are documented in IR 1218748 and evaluated under EC 384463.

Re-examination of indication of wear due to minor movement of the Core Spray Sparger Brackets was performed. The Core Spray Sparger Bracket at 190 degrees showed no change from the previous inspection in Q1R19. This indication is documented in IR 1218692 and evaluated under EC 384463.

Indications were observed in HAZ of Jet Pump 13/14 Riser pipe RS-2 weld. The scope of the RS-2 weld inspections was expanded to the remaining 5 RS-2 welds. No additional indications were observed in the other 9 RS-2 welds. These indications are documented in IR 1217155 and evaluated for continued service under EC 384624.

Multiple indications (gouges and rub marks) were identified on all four of the Steam Dryer wall support lugs. These indications were previously observed in Q1R19.

A comparison of the inspection results from Q1R21 to Q1R19 found no change to the previous indications and no new indications were identified. These indications are documented in IR 1218242 and evaluated for continued service under EC 384463.

Quad Cities will continue to monitor these conditions in accordance with the Reactor Internals Program.

8 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-1 Quad Cities Unit 1 ASME Section XI Outage Summary ( 4 th Interval)

Report Number Component Class Category Item Inspection Results QIR21-087 NIANOZ I B-D B3.90 UT NRI QIR21-089 NIB NOZ I B-D B3.90 UT NRI Q I R21-091 N9 NOZ I B-D B3.90 UT NRI VT2-040 NIO IRS I B-D B3.100 VT-2 Relief 14R-0I Acceptable QIR21-086 NIA IRS I B-D B3.100 UT NRI QIR21-088 NIB IRS I B-D B3.100 UT NRI QIR21-090 N9 IRS I B-D B3.100 UT NRI QIR21-093 RPV-STAB-270 I B-K B10.10 Surface NRI QIR21-092 RPV-SSLH I B-K Bl0.10 Surface NRI QIR21-078 3204D-W- 102A I B-K BI0.20 Surface NRI QIR21-055 1-203-ASB-3B I B-G-2 B7.50 VT-I NRI QIR21-056 1-203-ASB-3E I B-G-2 B7.50 VT-I NRI QIR21-057 1-203-ASB-4A I B-G-2 B7.50 VT-I NRI QIR21-058 1-203-ASB-4B I B-G-2 B7.50 VT-I NRI QIR21-059 1-203-ASB-4E I B-G-2 B7.50 VT-I NRI QI R21-060 1-203-ASB-4F I B-G-2 B7.50 VT- I NRI Q I R21-048 I-203-3A I B-G-2 B7.70 VT- I RI/Acceptable by Repair Q I R21-049 1-203-3B I B-G-2 B7.70 VT- I RI/Acceptable by Repair Q1R21-050 I-203-3E 1 B-G-2 B7.70 VT- I RI/Acceptable by Repair Q 1R21-051 1-203-4A I B-G-2 B7.70 VT- I RI/Acceptable by Repair QIR21-052 1-203-4B 1 B-G-2 B7.70 VT- I RI/Acceptable by Repair QIR21-053 I-203-4E I B-G-2 B7.70 VT- I RI/Acceptable by Repair QIR21-054 I-203-4F I B-G-2 B7.70 VT- I RI/Acceptable by Repair NDE-627 I-0202-4A I B-G-2 B7.70 VT-I RI/Acceptable by Repair RT-001 RT-00 1-0203-3D-SI I B-M-I B 12.40 RT (PO# 46308 1) Acceptabl" RIN# 192644 I-0203-3C I B-M-2 B12.50 VT-3 Acceptable NDE-511 1-0203-4B 1 B-M-2 B12.50 VT-3 NRI NDE-610 1-0202-4A I B-M-2 B 12.50 VT-3 Acceptable NDE-547 1-1001-50 1 B-M-2 B12.50 VT-3 NRI N/A RPV INTERIOR I B-N-I B 13.10 Relief 14R- 15 Acceptable N/A RPV INTERNALS I B-N-2 B 13.20 Relief 14R- 15 Acceptable Q I R21-084 CRD HOUSINGS I B-O B14.10 Surface NRI (BOTTOM)

QIR21-085 CRD HOUSINGS I B-O B14.10 Surface NRI (TOP)

Q I R21-040 1025-58 2 C-B C2.31 Surface NRI Q I R21-041 1025-62 2 C-B C2.31 Surface NRI Q IR21-043 1025-W-21 IA 2 C-C C3.20 Surface NRI QIR21-072 1404-W-216A 2 C-C C3.20 Surface NRI Q I R21-067 1402-W-204A 2 C-C C3.30 Surface NRI Q I R21-046 10S-F16 I R-A R1.11 UT-E NRI Q IR21-047 10S-S15 I R-A R1.1I UT-E NRI 9 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206'h Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-1 (continued)

Quad Cities Unit 1 ASME Section XI Outage Scope (4th Interval)

Report Number Component Class Category Item Inspection Results Q 1R21-044 10AD-S3 1 R-A R.1 I UT-E Acceptable Q 1R21-079 32A-SIO 1 R-A R 1.11 UT-E NRI Q IR21-080 32E-SO 1 R-A RI.1 I UT-E NRI QIR21-081 32F-SO 1 R-A RI.1 UT-E NRI QIR21-032 1009A-5 2 R-A RI. I UT-E NRI Q IR21-033 1009A-6 2 R-A R1.11 UT-E NRI Q IR21-034 1009A-8 2 R-A R 1.11 UT-E NRI Q 1R21-035 1009A-9 2 R-A R1.11 UT-E NRI VT2-040 0209A-FI I R-A R1.20 VT-2 NRI VT2-040 0209A-FI5 1 R-A R1.20 VT-2 NRI VT2-040 0209A-F9 1 R-A R1.20 VT-2 NRI VT2-040 0209B-FI 1 1 R-A RI.20 VT-2 NRI VT2-040 0209B1-F14 I R-A R1.20 VT-2 NRI VT2-040 0209B-F7 I R-A RI.20 VT-2 NRI VT2-040 1265-F117 1 R-A R1.20 VT-2 NRI VT2-040 1265-F22 I R-A R1.20 VT-2 NRI QI R21-025 03-FIA I R-A R1.20 UT-E NRI QIR21-061 12S-S IIR I R-A RI.20 UT-E NRI QI R21-062 12S-S 13R I R-A R1.20 UT-E NRI Q 1R21-063 12S-S 14R I R-A RI.20 UT-E NRI Q 1R21-075 30B-S36 I R-A RI.20 UT-E NRI Q 1R21-037 1025-13 2 R-A RI.20 UT-E NRI QIR21-038 1025-26 2 R-A RI.20 UT-E NRI Q IR21-039 1025-5 2 R-A R1.20 UT-E NRI QIR21-064 1401-5 2 R-A RI.20 UT-E NRI QI R21-065 1402-4 2 R-A RI.20 UT-E NRI QI R21-066 1402-5 2 R-A RI.20 UT-E NRI QIR21-001 0200-G-139 I F-A F11.10 VT-3 NRI QI R21-003 0200-M-170 I F-A Fi.b10 VT-3 NRI Q IR21-004 0200-M-173 I F-A FI.10 VT-3 NRI QIR21-007 0200-W-124.1 1 F-A FI.10 VT-3 NRI QIR21-077 3204D-W- 102 1 F-A FI.10 VT-3 Acceptable Q IR21-042 1025-W-211 2 F-A F1.20 VT-3 NRI Q 1R21-070 1404-W-201 2 F-A F1.20 VT-3 NRI Q I R21-068 1404-M-205 2 F-A F1.20 VT-3 NRI 10 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206"' Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-1 (continued)

Quad Cities Unit 1 ASME Section XI Outage Scope (4th Interval)

Report Number Component Class Category Item Inspection Results Q IR21-069 1404-M-211 2 F-A 171.20 VT-3 NRI Q I R21-071 1404-W-216 2 F-A F1.20 VT-3 NRI QIR21-073. 2306-M-203 2 F-A F1.20 VT-3 NRI QIR21-074 2306-M-205.1 2 F-A F1.20 VT-3 NRI VT3-034 0200-W- 182 1 F-A F1.40 VT-3 NRI Q I R21-009 0200-W- 184 1 F-A F1.40 VT-3 NRI Q I R21-006 0200-W- 109 A&B I F-A F1.40 VT-3 NRI QIR21-002 0200-M-112 1 F-A Fl.40 VT-3 NRI Table 3.1-1A Follow Up Exams in Accordance with IWF-2420(b) (4 th Interval)

Report Number Component Class Category Item Inspection Results QIR21-076 3204C-W-101 A&B I F-A F7.10 VT-3 NRI Table 3.1-1B Quad Cities Unit 1 ASME Section XI Limited Coverage Summary (4th Interval)

Report Number Component Class Category Item Inspection ASME % Coverage Q IR21-087 N I1A Nozzle I B-D B3.90 UT 34.2%

Q IR21-089 N IB Nozzle I B-D B3.90 UT 34.2%

Q 1R21-091 N9 Nozzle I B-D B3.90 UT 81.9%

Q I R21-025 03-FIA I R-A R1.20 UT 86.2%

Q IR21-009 0200-W- 184 1 F-A F1.40 VT-3 7%

11 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-2 Quad Cities Unit 1 Pressure Testing Summary (4 th Interval)

Third Period Component Component Category Inspection Work Relief Class Order(s) Request Remarks Class I piping extended RX Class I B-P Visual, VT-2 01256590 14R-07 boundary System leakage Test.

Partial 3' Period Class 2 System Leakage test of RX Class 2 C-H Visual, VT-2 01256590 14R-07 various inaccessible on line piping including - MS, FW, CS, RHR, HPCI, RCIC RX Head Flange Leak RX Class 2 C-H Visual, VT-2 01256420 14R-05 detection line System leakage test CRD Class 2 C-H Visual, VT-2 01379575 14R-06, Reactor Building HCU 14R-07 System Leakage Test Scram Discharge Reactor Building HCU Volume Class 2 C-H Visual, VT-2 00944870 14R07 Scram Discharge Volume System Leakage Test RHR' Class 2 C-H Visual, VT-2 01261134 N/A RHR B Spray MSIV Rm piping HPCl'& FW ' Class 2 C-H Visual, VT-2 01262207 N/A HPCI & FW MSIV Rm Piping System Leakage Tests SBLC Discharge Piping SBLC' Class 2 C-H Visual, VT-2 01261132 N/A Explosive Valves to RX I_ I I I System Leakage Test General Note: Q I R21 is the first of two outages during the third period for Unit I which is scheduled to end April 1,2013. The above CS, RHR B, HPCI, FW and SBLC inspections address portions of the Class boundaries primarily accessible during cold shutdown. The balance of those systems will be inspected non-outage. Remaining portions examined online during the current period will be reported in the Q2R21 and QIR22 Post Outage (90 Day) Summary Reports.

'Note: Partial system leakage test. Balance of the system is to be examined by end of period.

12 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-3 Quad Cities Unit 1 Snubber Functional Tests (4th Interval)

Snubber EPN / ISI Number Class Category Item Removed Snubber/ sDated Number Installed Snubber Inspection Results 10% Sample Group 1-1403-1/ Removed FT 5/19/2011 Pass 1403-W- 103 A&B Installed FT 5/12/2011 Pass 1-023 1-0202-A23 / I F-A FI.10 Removed FT 5/13/2011 Pass 0200-M- 112 Installed FT 5/10/2011 Pass 1-027 1-3019-A27 / N/A N/A N/A Removed Fr 5/16/2011 Pass N/A Installed FT 5/3/2011 Pass 1-036 1-1025-36/ N/A N/A N/A Removed FT 5/3/2011 Pass N/A Installed FT 5/2/2011 Pass 1-039 1-1629-A39 / N/A N/A N/A Removed FT 5/3/2011 Pass N/A Installed FT 5/3/2011 Pass 1-044 1-0201-C44 / I F-A FI. Removed FT 5/17/2011 Pass 0200-M- 172 Installed FT 5/3/2011 Pass 1-061 1-3019-B61 / N/A N/A N/A Removed FT 5/14/2011 Pass N/A Installed FT 5/4/2011 Pass 1-076 1-3001-D76 / I F-A F1.10 Removed FT 5/14/2011 Pass 3001D-M-102.1 Installed FT 5/3/2011 Pass 1-1025-81 / Removed FT 5/5/2011 Pass 1025-M-216 Installed FT 5/4/2011 Pass 1-1025-84/ Removed FT 5/10/2011 Pass 1025-M-202 Installed FT 5/5/2011 Pass 1-095 1-10W15-A95 / 2 F-A F1.20 Removed FT 5/6/2011 Pass 1015A-W-202 A&B Installed FT 5/3/2011 Pass 1-100 1-1015-AIOO/ 2 F-A F7.20 Removed FT 5/6/2011 Pass 1015A-W-206 A&B Installed FT 5/2/2011 Pass 1-101 1-1024-C 101 / N/A N/A N/A Removed FT 5/10/2011 Pass N/A Installed FT 5/5/2011 Pass Service Life Monitoring Group 1-1403-2 / Removed FT 5/19/2011 Pass 1403-W-103 A&B Installed FT 5/12/2011 Pass 1-016 1-0201-A16/ I F-A F7.10 Removed FT 5/20/2011 Pass 0200-W-154 Installed FT 5/12/2011 Pass 1-018 1-0202-A 18 / I F-A FI. Removed FT 5/14/2011 Pass 0200-M-110 Installed FT 5/5/2011 Pass 1-022 1-0202-A22 / I F-A F1.10 Removed FT 5/13/2011 Pass 0200-M-111 I FInstalled FT 5/13/2011 Pass 1-026 1-3019-A26 / N/A N/A N/A Removed FT 5/14/2011 Pass N/A Installed FT 5/3/2011 Pass 1-032 1-0300-0032 / N/A N/A N/A Removed FT 5/16/2011 Pass N/A Installed FT 5/2/2011 Pass 1-045 1-0201-M45 / 1 F-A FI.1 Removed FT 5/12/2011 Pass 0200-M-175 Installed FT 5/3/2011 Pass 1-046 1-0201-F46 / I F-A FiO Removed FT 5/20/2011 Pass 0200-M-174 Installed FT 5/3/2011 Pass 1-048 1-0202-A48 / I F-A F110 Removed Fr 5/14/2011 Fail 0200-M-170 Installed Fr 5/10/2011 Pass 1-073 1-3019-C73 / N/A N/A N/A Removed FT 5/16/2011 Pass N/A Installed FT 5/3/2011 Pass 1-122 1-1025-122 / I F-A 17.10 Removed FT 5/18/2011 Fail 1025-M-101 A&B Installed FT 5/5/2011 Pass 1-123 1-1025-123 / I F-A FI.10 Removed FT 5/18/2011 Pass 1025-M-101 A&B Installed FT 5/5/2011 Pass 1-124 1-1025-124/ 1 F-A FI. Removed FT 5/18/2011 Pass 1025-M- 102 A&B Installed FT 5/5/2011 Pass 1-1025-125/ Removed FT 5/18/2011 Pass 1025-M-102 A&B Installed FT 5/5/2011 Pass 13 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit I Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-4 Quad Cities Unit 1 Conditions Noted on ASME Code Components During ISI and Corrective Actions (4 th Interval)

Con ponent ID Description / Resolution Pressure Test During the Unit I Class I Leakage Test the listed bolted or threaded components were identified to be leaking. No through wall leaks were identified. Work Order 01256600 was issued to tighten minor leakage. Corrective actions were taken as follows (Reference VT report # VT2-040 dated 05/31/11 in Work Order 1256590):

Mechanical connection at CRD's 26-31, Engineering evaluation (EC# 384699) was performed as permitted by Relief Request 14R-07 of bolted 26-23, 22-47, 26-55, 34-15 and LPRM connections. Reference IR's 1222912 and 1222917.

24-17 HCU small bore valve body to bonnet Engineering evaluation (EC# 384694) was performed as permitted by Relief Request 14R-07 of bolted leaks, connections. Reference IR's 1222894, 1222902, 1222872, 1222861, and 1222885.

South Bank HCUs: 1-305-127-26-55, 1-305-127-14-35, and 1-305-101-22-03 North Bank HCUs: 1-305-127-46-27 and 1-305-127-42-27 1-0262-2-4A Minor Leakage identified in IR 1222926. Engineering evaluation (EC# 384713) was performed as permitted by Relief Request 14R-07 of bolted connections.

1-1001-30A Minor Leakage identified in IR 1222926. Engineering evaluation (EC# 384713) was performed as permitted by Relief Request 14R-07 of bolted connections.

1-0220-14-A Minor Leakage identified in IR 1222926. Engineering evaluation (EC# 384713) was performed as permitted by Relief Request 14R-07 of bolted connections.

Visual Inspections Bolting on ERV and SRV's IR 1221112 written for studs and nuts scheduled for ISI and damaged during removal process (no service induced indications). All valves that were removed from the same group received VT-I. All damaged parts were replaced. Components required B-G-2 exam for Inservice Inspection.

Decon Flange Bolting: IR 1216262 written for studs and nuts scheduled for ISI and damaged during removal process (no service induced indications). Only stainless flange on recirc system that was opened, therefore no expansion was required. All damaged parts were replaced; Component required B-G-2 exam for Inservice Inspection.

1-02024A Body to Bonnet Bolting IR 1219963 written for studs and nuts scheduled for ISI and damaged during removal process (no service induced indications). All valves that were opened from the same group received VT-I. All damaged parts were replaced. Component required B-G-2 exam for Inservice Inspection.

1-0202-4B Body to Bonnet Bolting IR 1221654 written for studs and nuts scheduled for IS1 and damaged during removal process (no service induced indications). All valves that were opened from the same group received VT- 1. All damaged parts were replaced. Component required B-G-2 exam for Inservice Inspection.

14 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206'h Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.2-1 Quad Cities Unit 1 BWRVIP-75-A/GL 88-01 Outage Summary Pre/Post Report Number Component Class Outage Inspection Category Results Q IR21-015 02AS-S3 I C UT NRI Q1R2I-020 02BS-F2 1 C UT NRI Q I R21-022 02BS-F6 I C UT NRI Q I R21-024 02L-F6 1 C UT NRI QIR21-011 02AD-S2 I C UT NRI QI R21-013 02A-S4 I C UT NRI Q I R21-012 02AD-S6 I C UT NRI QIR21-016 02BB-S10 1 C UT NRI Q1R21-017 021B3D-F8 1 C UT NRI Q I R21-018 02BD-S5 1 C UT NRI Q I R21-019 02BD-S6 I C UT NRI Q I R21-045 IOHV-F1' I C UT NRI Q I R21-044 IOAD-S32 I C UT Acceptable QIR21-023 02BS-S12 1 E UT Acceptable QIR21-010 02AD-FI2 3 I E UT NRI Q I R21-021 02BS-F43 I E UT Acceptable 2 INote: weld is a dissimilar metal weld examined by automateu ultrasonic technique wln Supplement lu pronle.

Note: Weld is credited towards ASME Section XI Risk Informed ISI Program population.

3 Note: Weld overlay received subsequent UT three cycles after initial overlay in accordance with BWRVIP-75-A.

15 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.3 Quad Cities Unit 1 Number and Percentage of Examinations Completed (4th Interval)

Category Exams Completed in QIR21 Exams Completed to Date Total Exams in the Interval Percentage Complete for Interval 4

B-A 0 22 29 76 9

B-D 7 50 51 98 B-G-l' 0 8 9 89 B-G-22 14 33 33 100 B-K 3 11 11 100 B-L-2 5 0 1 1 100 B-M-1 1 1 1 100 B-M-2 5 4 10 10 100 B-N-18 N/A N/A N/A N/A B-N-28 N/A N/A N/A N/A B-0 4 2 2 2 100 B-P 3 N/A N/A N/A N/A C-A 0 2 4 50 C-B 7 2 12 14 86 C-C 3 10 I1 91 C-H3 N/A N/A N/A N/A F-A6 16 70 78 90 R-A_° 21 99 115 86

'Note: Category B-G-1 contains reactor vessel studs and nuts. 1/3 of the reactor vessel studs, nuts, washers and ligaments are examined each period. Since the component number is repeated in this category, each period may result in greater than the limiting percentage of 2 exams.

Note: B-G-2 category includes bolted connections when components are opened as well as in place under tension.

3 Note: Category B-P and C-H exams are pressure tests tracked under Table 3.1-2.

4 Note: Exam Category B-A and B-O are scheduled to coincide with previous interval to maintain ten year interval between exams and are performed in accordance with IOCFR50.55a Period completion percentage does not apply.

5 Note: Categories B-L-2, and B-M-2 are inspected and credited under the Repair/Replacement Program only when the component is disassembled. Only one of each type of valve and pump are required to be examined.

6 Note: Only 71 total exams are required to meet combined Class 1 and 2 requirements for F-A category, however additional exams were scheduled to better distribute exams between systems and based on discovery of indications on Unit 2. Previous counts included the scope expansion of several Class 1 hangers which artificially raised the inspection numbers for code credit.

7 Note: Only 12 components are required to be examined in Category C-B, however several are 100% obstructed and are required to be examined every period by VT-2 in accordance with Item Number C2.33. Therefore, percentage completion for the interval by item number does not apply.

8 Note: B-N- I and B-N-2 Category Exams are credited by the performance of the BWRVIP program in accordance with Relief Request 14R- 15.

9 Note: Category B-D exam population has been reduced as a result of Relief Request 14R- 17.

1°Note: Category R-A exam population from the 2005B RISI Model requires 105 components be inspected in the 10-year interval. 115 Components are scheduled for examination to improve distribution by system. The distribution changes across the interval based on Risk Model updates.

16 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 4.0 Repair / Replacement Summary 4.1 NIS-2 Index Table 4.1-1 Quad Cities Unit 1 NIS-2 List Program Number Work Request Component EPN ASME XI Class Number or Purchase Order 09-035 1240358-01 1-0203-3E 1 09-040 1092064-01 1- 1001-67C 2 09-070 & 09-071 1265266-02, -06 1- 1410-1.5" 2 09-103 1104615-01 1-1001-67A 2 10-003 1301067-01 Spare 1 10-009 PO# 452106 0-Spare (S/N BY94637) 1 10-037 & 10-096 1034869-02, -03 I- 1106B 2 10-055 1220810-01 1-0203-4E 1 10-056 1220808-01 1-0203-4A 1 10-057 1220809-01 1-0203-4B I 10-058 1220807-01 1-02034F I 10-060 1260440-01 1-0203-3A 1 10-061 1257055-01 1-0203-31B 1 10-062 1079828-01 1-0203-31E 1 10-063 1277414-01 1-0201-A16 1 10-064 1277415-01 1-0202-A18 1 10-065 1277416-01 1-0202-A22 1 10-066 1277417-01 1-0202-A23 1 10-067 1277421-01 1-0201 -C44 1 10-068 1277422-01 1-1025-81 2 10-069 1277423-01 1-1025-84 2 10-070 1277424-01 1-1015-A95 2 10-071 1277425-01 1-1015-A100 2 10-072 1277432-01 1-3001-D76 1 10-073 1277433-01 1-1025-122 1 10-074 1277434-01 1-1025-123 1 10-075 1277435-01 1-1025-124 I 10-076 1277436-01 1-1025-125 1 10-077 1277437-01 1-1403-1 1 10-079 1277438-01 1-1403-2 I 10-080 1277439-01 1-0201 -M45 1 10-081 1277440-01 1-0201--F46 1 10-093 1261768-02 1-1001-125B 2 10-097 1252124-02 Head Vent Bolting (N7) 1 10-098 1226741-11 1-0202-A48 I Various Control Rod 10-100 thru 10-127 1287161 Drives 1 10-130 799592-01 1-1001-50 1 10-131 1267203-01 I-1402-38B 2 11-001 PO# 458819 0-Spare (S/N BK6251) 1 11-003 PO# 467994 0-Spare (S/N 61300/52) 1 11-012 PO# 462858 0-Spare (S/N 171) 1 11-013 PO# 472689 0-Spare (S/N 120) 1 11-016 PO# 463081 0-Spare (S/N BK7062) I 17 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 4.1-1 Quad Cities Unit 1 NIS-2 List Program Number Work Request Component EPN ASME XI Class Number or Purchase Order 11-017 PO# 463081 0-Spare (S/N BX00290) 1 11-024 & 11-026 1226741-01, -64 1-0202-A I 1-0202A-28"11-025 1433281-01 Decontamination Flange I 11-029 1280161-01 1-0203-2B 1 11-035 97104789-01 1-0202-4A 1 11-036 367241-01 1-0202-4B 1 11-037 367241-25 M-994D-23 1 11-038 1440147-01 M- 1610-06 2 18 of 19

Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 4.2 NIS-2 Forms (Attached) 19 of 19

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 11/19/09 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 09-035 WO: 1240358-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No, etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Com ponents Repaired or Replaced, and Re placementComponents:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Electromatic Relief Dresser BY 94632 N/A 1-0203-3E N/A Replacement No Valve I

7. Description of Work: Replaced Electromatic Relief Valve and bolting.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating pressure [ Exempt LI (I:' Other ' Pressure __ psi Test Temp._ IF
9. Remarks: None.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Prop-ram Certificate of Authorization No. N/A Expiration Date N/A Signed * [* t* *r1,'oA-`,, 5,'v,,d Date t 200 nweder or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period q / b6) c! to i./1/ ao , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

(ý, 1) 11 , AýA Commissions \ i5 q tIr.pect~Js blbnatu're I National Board, State, Province, and Endorsements 20 I -

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 12/08/2010 4300 Winfield Road Sheet: I of .I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 09-040 WO: 1092064-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 2
5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Corn onents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd, Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Check Valve Crane Nuclear UTC 2746567 N/A 1-100 1-67C N/A Replacement No

7. Description of Work: Replaced check valve.
8. Tests Conducted: Hydrostatic E5 Pneumatic E5 Nominal Operating Pressure [ Exempt 51 Other 5 Pressure __ psi Test Temp. - 'F
9. Remarks: None.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear 10CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -,AX4;W ' /,S/

Owner or Owner's Designee, Title

.1,o Date /Z/ 20 /0 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 8,66(_ aO to ' 1L to , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damgor a loss of any kind arising from or connected with this inspection.

Commissions 14?* D57 yt IL ziit

/'¶ spectors Signature National Board, State, Province. and Endorsements Date ý ý15( 20 1o

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 11/19/09 4300 Winfield Road Sheet: I of 1 Warrenville, I1. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 09-070 & 09-071 WO: 1265266-02 & -06 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Core Spray, Class 2
5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N-416-3
6. Identification of Co ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) ipe Consolidated UTC 2794421 N/A 1-1410-1.5"-DX N/A Replaced No

7. Description of Work: Replaced pipe.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt El Other Ml Pressure __ psi Test Temp._ OF
9. Remarks: None.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear 10CFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed F*Vk , O'kner°tOwner'§0D6ignee, To,-

,er,.tS P Title Svk.- Date b- .Lz,- 1 2001 -

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period - 6 '/?/0 to 11 2.7 &Q , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ý/P a~ v Commissions L i fnspectZgsrgýAure National Board, State, Province, and Endorsements Date *20 L) )

Date 20

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 02/04/2010 4300 Winfield Road Sheet: 1 of I Warrenville, I. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 09-103 WO: 1104615-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 2
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Re placement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Check Valve Crane Nuclear UTC 2845270 N/A 1-1001-67A N/A Replaced No Stud Various UTC 2835154 N/A 1-100 1-67A N/A Replaced No Nut NOVA UTC 2847270. N/A 1-100-67A N/A Riaced N

7. Description of Work: Replaced check valve and bolting.
8. Tests Conducted- Hydrostatic E] Pneumatic [3 Nominal Operating Pressure 1Z Exempt El Other -' Pressure _ psi Test Temp. - 'F
9. Remarks:. None.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. - N/A Expiration Date N/A Signed (3Me4.L , ý6wjný Date F&1,ýgm u%!AOt 'L 20 I0 V - Fwnef or Owner'f"Designde, Title %J I, CERTIFICATE OF INSERVICE INSPECTION I.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by.. S_ of Hartford. Connecticut have inspected the components described in this Owner's Report during the period A4~iA2I t/,zS/ to .&..it, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section X1.

By signing this certificate, neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _ =_401.0_ Commissions )-.L ISSI Nalikniia B0 rd. Stawe,Pnrvince. and Endnrsemcnls

..... /0 Date /0 20D

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/8/2011 4300 Winfield Road Sheet: 1 of I Warrenville, I. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-003 WO: 1301067-01 & 02 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Feed Water, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Disc/Seat Ring Crane UTC 2883569 N/A Spare N/A Replaced No Assembly

7. Description of Work: Replaced disc/seat ring assembly.
8. Tests Conducted: Hydrostatic F1 Pneumatic El Nominal Operating Pressure El Exempt 0 Other Fl Pressure __ psi Test Temp. - 'F
9. Remarks: None.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed CW-J n"-- e r t.,, Peg, S,,Pw Oltmer d~rOwner:'s Degigdee,- TitleF t"

Date ,..1,0 20 It CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described inthis Owner's Report during the period i-3'R-%, to ,'z?-.1 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XL By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __ __ Commissions v,1*,-OE5A ,A,, /Lz- ',

Inspctors Signature National Board, State, Province. and Endorsements te 2"' )u.L 20 11 te ~ 20

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 5/2/2011 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 10-009 WO: P.O. 452106 RIN 192644 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC 29306 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: ASME Section III Edition: 1995 Addenda: 1996 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Electromatic Relief Dresser Industries BY94637 N/A UTC 2707510 N/A Repair / No Valve I I I -Replacement

7. Description of Work: Removal of cracked tack welds and machine inlet flange face.
8. Tests Conducted: Hydrostatic El Pneumatic LI Nominal Operating Pressure Ii Exempt Z Other [] Pressure _ psi Test Temp. - F
9. Remarks: An internal VT-3 examination performed. Pressure test to be performed post-installation.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed "I,","Date AA, I  ? 201L

  • V Owiker or Owner's D3hignee, Titld CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois_ and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Zo-4 /o to 6 r-w ii , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _Commissions It. tkrsA*,.t L.-,

IS ture National Board, State, Province, and Endorsements IDate 1

Date

  • *,t*t 4 fnbt 20 20 I!

11

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 5/26/2011 4300 Winfield Road Sheet: I of I Warrenville, I!. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-037 & 10-096 WO: 1034869-02 & -03 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Standby Liquid Control, Class 2
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Trigger Assembly Conax Buffalo UTC 2873952 N/A I-I 106B N/A Replacement No Valve Pug Conax Buffalo UTC 2864700 N/A I-1 106B N/A Replacement No

7. Description of Work: Replaced trigger assembly and valve plug.
8. Tests Conducted: Hydrostatic El Pneumatic 0I Nominal Operating Pressure 0 Exempt F1 Other E] Pressure __ psi Test Temp. - F
9. Remarks: None.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A- Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Itv,,*- ign-, itp, - Date -120.11

-'"V O~vner or Owner's-Desi nee, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 11r,*i I, to zi rMIN , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_1__ ___ Commissions J9',-1s5,AtJV . ?'ell

/ -, Inspectors Signature National Board, State, Province, and Endorsements Date I- J U.- 20 h*

Date ~JO~ 20 ~'

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/22/2011 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: 1 2.Plant: Quad Cities Generating Station Program No.: 10-055 WO: 1220810-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 / ASME Section III Edition: 1967 / 1965 Addenda: N/A / 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Co ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Valve Cons Safety S/N BLI 132 N/A I-0203-4E N/A Replacement No Valve Stud Nova UTC 2876355 N/A 1-0203-4E N/A Replacement No Hvdranut Nova UTC 2885680 N/A t-0203-4E N/A Replacement No Hex Nuts Nova UTC 2712551 N/A 1-0203-4E N/A Replacement No Description of Work: Replaced valve and bolting.

8. Tests Conducted: Hydrostatic [] Pneumatic F-1 Nominal Operating Pressure 0 Exempt El Other F] Pressure _ psi Test Temp. - OF
9. Remarks: Performed VT-I on bolting.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 0"Date ____, __J_ _ _ _ 20.L Writv~or Owntr'sl De~signk-el, TleAr, CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period I?rt'i it to 4'1 r',,t ', , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or roperty damage or a loss of any kind arising from or connected with this inspection.

Sfpetor*.2Commissions Y1 Signature r-9 iwris Ar3i J-77 National Board, State. Province. andEndorsements Date iJ J- 20 _ _

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/16/2011 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-056 WO: 1220808-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: USAS B31.1 / ASME Section III Edition: 1967 / 1965 Addenda: N/A 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Valve Cons Safety Valve S/N BK6306 N/A I-0203-4A N/A Replacement No Stud Nova UTC 2740334 N/A 1-0203-4A N/A Replacement No Hydranut Nova UTC 2801055, N/A 1-0203-4A N/A Replacement No 2858112, 2885680 Hex Nut Nova UTC 2740332 N/A I-0203-4A N/A Replacement No

7. Description of Work: Replaced valve and bolting.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Z Exempt El Other F1 Pressure _ psi Test Temp. - 'F
9. Remarks: Performed VT-I on bolting and VT-3 on internals.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed a PrL . gs ,t'".'.r Pro!). Date _ _ __ _ _ _ _ 20//

V UJvnef or Owner', DMsignee,'Fitle CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,-

2 Msi" to -74 o'( k\ , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ __ _ _ _ __ _ _ _ Commissions nstlz* -I,z tInspectos f - Signature National Board, State, Province, andEndorsements Dnte I* ,.Jut--

Dante 11JuL.. 20 it

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 6/22/2011 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-057 WO: 1220809-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 / ASME Section III Edition: 1967 / 1965 Addenda: N/A / 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Co ponents Repaired or Replaced, and Re placement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Valve Cons Safety S/N BK7159 N/A 1-0203-4B N/A Replacement No Valve Stud Nova UTC 2740334 N/A 1-0203-4B N/A Replacement No Hvdranut Nova UTC 2885680 N/A 1-0203-4B N/A Replacement No Hex Nuts Nova UTC 2740332, N/A 1-0203-4B N/A Replacement No 2735812

"` escription of Work: Replaced valve and bolting.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure [ Exempt F1 Other Fl Pressure _ psi Test Temp. _ 'F
9. Remarks: Performed VT-I on bolting and VT-3 on valve internals.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed r ýA) -, u* 20 1 VJ O',fner br Owner'sDesignee,1Tile *-

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period k? [,,0'A W, to Z4 rn.'m

,, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or

. perty damage or a loss of any kind arising from or connected with this inspection.

_____________________________________Commissions -Srcisw A u3t1 U -Inspectors Signature National Board. Slate. Province, and Endorsements Date 1JuL 20 1)

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/5/2011 4300 Winfield Road Sheet: I of /

Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-058 WO: 1220807-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Ouad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: USAS B31.1 / ASME Section III Edition: 1967 / 1965 Addenda: N/A / 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Valve Cons Safety Valve S/N BK7158 N/A 1-0203-4F N/A Replacement No Stud Nova UTC 2740334, N/A 1-0203-4F N/A Replacement No 2859490,.2876355 Hydranut Nova UTC 2885680 N/A 1-0203-4F N/A Replacement No Hex Nuts Nova UTC 2712551 N/A 1-0203-4F N/A Replacement No

7. Description of Work: Replaced valve and bolting.
8. Tests Conducted: Hydrostatic E] Pneumatic F1 Nominal Operating Pressure 10 Exempt El Other LI Pressure __ psi Test Temp. 'F
9. Remarks: Performed VT-I on bolting.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ("jVJ L-A t. X, -,f r- v Ovher or Owner's Detighee, Titld pi , Date ,ivtvV 2011 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period iL-,,o,- to Z4 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

________________ __________________________________________Commissions r ig . Ln nd I ~t ( InselrsSignature Nafional Board. Stale,P'rovince. and Undorsemnents Date /I -Jut- 20 P*

/t Jt..20 1

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/24/2011 4300 Winfield Road Sheet: I of I Warrenville, I1. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-060 WO: 1260440-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: ASME Section III Edition: 1968 Addenda: Winter 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Valve Target Rock S/N 171 N/A 1-0203-3A N/A Replacement No Stud Nova UTC 2720530. 2708313 N/A 1-0203-3A N/A Replacement No Hydranut Nova UTC 2846357, 2866535, N/A 1-0203-3A N/A Replacement No

" 2885679 Hex Nut Various UTC 2733070, 2725214 N/A 1-0203-3A N/A Replacement No

7. Description of Work: Replaced valve and bolting.
8. Tests Conducted: Hydrostatic Dl Pneumatic L1 Nominal Operating Pressure 0 Exempt El Other [] Pressure _ psi ' Test Temp. - F
9. Remarks: Performed VT-I on bolting.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed C." V,

_*t-, 94,4M "Lg!ý 5v",,

Ol~ner or Owner'sibesigne6,,Title Date ,,J  : 2011 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by I-SB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i , to Z M o , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_Commissions 1-Risi ,

" L*, .,

Itn-p'ectirs Signature National Board, State. Province, and Endorsements Date 1, 1.,,. 20 '1 Date it 20

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/14/11 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-061 WO: 1257055-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: ASME Section III Edition: 1995 Addenda: 1996 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Valve Dresser Industries S/N BY94637 N/A I-0203-3B N/A Replacement No Stud Nova UTC 2841985 N/A 1-0203-3B N/A Replacement No Hydranut Nova UTC 2883910, N/A 1-0203-3B N/A Replacement No 2727471, 2733672

7. Description of Work: Replaced valve and bolting.
8. Tests Conducted: Hydrostatic E3 Pneumatic El Nominal Operating Pressure 1Z Exempt El Other L] Pressure __ psi Test Temp. - F
9. Remarks: Performed VT-I on bolting.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed V k- V3wntr

,-\ ,. orOwdsDigt, 0-M.-t t P '!t)o Ti tit:

- Date JI,*

J

1. 20LL CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i3 'mxy m, to zMl V, o , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_________________________________Commissions N atl! AýJ . VA inspectors signature National Board, State. Province, and Endorsements Date i JUL 20 1,

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/14/11 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: 1 2.Plant: Quad Cities Generating Station Program No.: 10-062 WO: 1079828-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: ASME Section III Edition: 1995 Addenda: 1996 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Com ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Valve Dresser Industries S/N BX00290 N/A I-0203-3E N/A Replacement No Stud Nova UTC 2841985 N/A 1-0203-3E N/A Reolacement No Hydranut Nova UTC 2885666 N/A I-0203-3E N/A Replacement No

7. Description of Work: Replaced valve and bolting.
8. Tests Conducted: Hydrostatic r] Pneumatic E Nominal Operating Pressure [ Exempt E]

Other E] Pressure __ psi Test Temp. - 'F

9. Remarks: Performed VT-I on bolting.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 4 M4't , l r R! t-, pv* Date Jvlu, ai -2011 V O~nro we' einee, Tilde "

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,3 mA' i to z, t, Ip , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions +/-4.'& *r A ",  ?-.L

- peclors Signature National Board, State, Province, and Endorsements Date I'* *t._ 20 tl Date 0o 3"L 0t

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/201 I 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-063 WO: 1277414-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242' Expiration Date: N/A
4. Identification of System: Recirculation System, Class I
5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Pacific Scientific UTC 2873686 N/A 1-0201-A16 N/A Replacement No Co.__._

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic F1 Pneumatic El Nominal Operating Pressure El Exempt [0 Other n Pressure _ psi Test Temp. - F
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed kl$46IA A.00, !5Vj, -Date . 201(

"-VJOvner 6r Owner s resignee Title' CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period iL nm* t to 23 ,nrv

,I , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____Commissions wsr\3s Pitk f XL-A Inspectors Signature National Board, State, Province, arid Endorsements Plat+, Iq , \* 20 h Dater 11 \ý 20 h

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/201 1 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-064 WO: 1277415-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Recirculation System, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Pacific Scientific UTC 2873688 N/A 1-0202-A18 N/A Replacement No Co......__.

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic El Pneumatic LI Nominal Operating Pressure F] Exempt 0 Other F1 Pressure __ psi Test Temp._ OF
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 45-" ,vj " Date dv-,e I 201L V Owler or Owner's Ddsighee, Tit*

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 0o'V , to , IN' , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_________________ Commissions ,a , a ILzn, Inspectors Signature National Board. State, Pnrvince, and Endorsements Date ot Jup 20 ),

Date ~i iw~ 20 I

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/2011 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-065 WO: 1277416-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Recirculation System, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Basic-PSA Inc. UTC 2877181 N/A 1-0202-A22 N/A Replacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic Ij Pneumatic E Nominal Operating Pressure El Exempt Z Other n Pressure - psi Test Temp._ OF
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed (fiA~L-- o 9--A pt* svw-r- Date \)Vw/e. i'2. 20tL.

T' OvJher or'Owner's Des'*gnee, Thtie '

CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period io f,, to ZI tnp.t t , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property dam ag loss of any kind arising from or connected with this inspection.

Commissions N8 L*t71/3r17 AN. UL 2Z.It hnspettus Signature National Board. State, Province. and Endorsements Date Io ..3u,-, 20 1' Date 11412

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/2011 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-066 WO: 1277417-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Recirculation System, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Com oonents Repaired or Replaced, and Re placement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Pacific Scientific UTC 2880878 N/A 1-0202-A23 N/A Replacement No Co..._,

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt 0 Other nl Pressure _ psi Test Temp._ 'F
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed V/

O P4 (Awner 6r Owner's lDestignee, Til1e ° Date \Jl'P- 12 20 11 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 0oiVW1ŽI, to 23 ftk. I , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _ _ _ _ _ _ Commissions t"k Mit15 AZ 'k -

ctots Signature National Board, State, Province, and Endorsements r)ntp iti ý I k I VJ 213 It fla~ ~20 i' 1

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/2011.

4300 Winfield Road Sheet: I of I Warrenville, I1. 60555 Unit: I 2.Plant: Quad Cities Generating Station ProgramNo.: 10-067 WO: 1277421-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Recirculation System, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Re placement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Pacific Scientific UTC 2873680 N/A 1-0201 -C44 N/A Replacement No Co.

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic ED Pneumatic El Nominal Operating Pressure [ Exempt [

Other M Pressure __ psi Test Temp. OF

9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ra r* Dvf, - 2o01 V Oftner o'r Owner's 19esi/gnee, Title '

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 'i .i'% to I- Mal it , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__Commissions Nagf75Awl ILZ I1

' 1ispectors Signature National Board, State, Province, and Endorsements Date ,h .Avi- 20 h Date /1 .A~,-. 20 ~

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 6/6/2011 4300 Winfield Road Sheet: I of I Warrenville, 11.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-068 WO: 1277422-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 2
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Co ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Pacific Scientific UTC 2873684 N/A 1-1025-81 N/A Replacement No Co.____.

Taper Pin Anvil UTC 2884833 N/A 1-1025-81 N/A Replacement No I International, Inc 1 1

7. Description of Work: Replaced snubber and taper pin.
8. Tests Conducted: Hydrostatic El Pneumatic ED Nominal Operating Pressure E Exempt [

Other LI Pressure __ psi Test Temp._ 'F

9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed c\' V k4, . %-bw Otnerot'Owner'& IesigneoTitl

-Date Jv*e- 1+ 20 1l CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of _ Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ý4rm'*I to C m& % , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ ___,_ _ _Commissions ,oe /3mt A m I i, ,t, I a Inspectors Sig[ature National Board, State, Province, and Endorsements Date 65 3, 20 11 Date ~$ '.Su~ 20 11

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/2011 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-069 WO: 1277423-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 2
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Co ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Pacific Scientific UTC 2873685 N/A 1-1025-84 N/A Replacement No Co.._.

Taper Pin Anvil UTC 2884833 N/A I- 1025-84 N/A Replacement No International, Inc I I

7. Description of Work: Replaced snubber and taper pin.
8. Tests Conducted: Hydrostatic F1 Pneumatic EJ Nominal Operating Pressure El Exempt [

Other r] Pressure _ psi Test Temp. OF

9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ,rAdAk Voftner ;or Owner't K~s~igneu. Title- 1- tDate rsin,,-

ne *vs 12- 20 l1 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 4-' . s r- to CG r',* , , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section X1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______________________ __________ Commissions Me(3,7S  ;. i 1L, zz,1 npe S natue National Board, State. Province, and Endorsements Date J* J'a* 20

  • Date iq J-ha 20 0~

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 6/30/2011 4300 Winfield Road Sheet: I of 1 Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-070 WO: 1277424-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 2
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. NatI Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber PSA UTC 2873681 N/A 1- 101 5-A95 N/A Replacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic [l Pneumatic El Nominal Operating Pressure El Exempt Z Other Fl Pressure _ psi Test Temp. - 'F
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed rvAAa , 4.t.4 re!!, evrr t eDate ,-Jv 1 201 t V - Pwhir or Owner's"Designef, Tit i CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period . r'mlI' to 6 r,** iý , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____Commissions Nfti-T4 ,zn,,

t IInspectors Signature National Board, State, Province, and Endorsements Date l ill_ 20 o Date ~ 20 t~

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/30/2011 4300 Winfield Road Sheet: I of I Warrenville, I1. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-071 WO: 1277425-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 2
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Co ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or N/A 1-1015-AIOO N/A Replacement No Snubber PSA UTC 2689766 .

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure U Exempt 0 Other E] Pressure _ psi Test Temp. 'F
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ,aftý 1 ,T,, h ,r Date UVl b 20/1 V Owner or Owfiet's Desitee,n'ttle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period C'll't I. to 6 M', 1, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ Commissions Ngrofgo r, Lz.,zii

- -tlipectors Signature National Board, State, Ptovince, and Endorsements D3ate 11Jt 9_1"1t*

ft JUL20 6s

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/30/2011 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-072 WO: 1277432-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Rplacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Lisega UTC 2843641 N/A 1-3001-D76 N/A Re lacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure F1 Exempt [

Other rl Pressure _ psi Test Temp. - 'F

9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed r\MA^L-IV Ow4er I Dat J f 201I or'Owner's Dsighee, Titlo I _

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois., and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period il rwl t to Iý rl- %,, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _ _ Commissions I'g gni 4-N ,t IZZ Inspectors Signature National Board. State, Province, and Endorsements Date 0, 3U*- 20 iý D2t~ I' 20 it

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/2011 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-073 WO: 1277433-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Lisega UTC 2873592 N/A 1-1025-122 N/A Replacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic El Pneumatic [I Nominal Operating Pressure El Exempt [

Other El Pressure __ psi Test Temp. - 'F

9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed C w orlOwner's

'V Ovdher 64,- ., ei Tit~le/r, ,gev,tc."

Deg-ig~tke. Date _ v__

__- 14 _ 201L CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period iG,6 V1II to I "'t,,, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _ _ _ _ _ Commissions ,-%Ztin AN iL ZIi r

  • nspectors Signat tire National Board, State, Province, and Endorsments 20 L

Date IS ýu " 20 1)

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/2011 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-074 WO: 1277434-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Re lacement Components:

Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or

_ a__ _ N/A_ __ 1-1025_123 _No)

Snubber Lisega UTC 2873603 N/A 1-1025-123 N/A Replacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic [ Pneumatic 0 Nominal Operating Pressure El Exempt 0 Other E] Pressure ___ psi Test Temp. - F
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed MA.N,-

AAA %rvi S,,pv.,r Date  %,Jv,,,.e-- I '2_ 20 11 V O ner or Owner's Delignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 16 --

"I I to i9 mi'l 1 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ "Commissions _ __ OR 13%ls ANIt It- ?t_

/ -"Inspeclors Signature National Board, State, Province, and Fndorsements l*te ill Ju* ?20 II Dante v4 u 2J

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/2011 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-075 WO: 1277435-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Ouad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Re placement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Lisega UTC 2873605 N/A 1-1025-124 N/A Replacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic E] Pneumatic E] Nominal Operating Pressure E Exempt [

Other F1 Pressure _ psi Test Temp. _ 'F

9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -V Vtn-, FPt,!,5 5-,p-vr Owiter or"Owner's IVe~gnee, Title "

Date 'Ov e. 1I1 2011 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /6 P"l', it to 73 rn'1 b , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2 _

19___ _ _ _ _ Commissions xAispSA Nt rt- Z-'

ft , S--)

" signature National Board, Slate. Pnwince. and Endors*mrents

")ate t* *,u,-J 20

  • Date 1.13uj 20 "

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/2011 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-076 WO: 1277436-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Com ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Lisega UTC 2873606 N/A 1-1025-125 N/A Renlacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic 0l Pneumatic El Nominal Operating Pressure El Exempt [

Other E] Pressure ___ psi Test Temp. 'F

9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed (" -S! pv-," Date v-t.L I fi 20 J1

-VOwlter or Owner's Des'iggfee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ic n It to 7, 1-, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _ _ _ _ _Commissions Hkic* k)1,) **-,

Inspector s Signature National Board, Stale. Province, and Endmirsements Date P3,.J 20 Ht Date ~ .SJ~ 20 II

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 6/30/2011 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-077 WO: 1277437-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. 1l. 61242 Expiration Date: N/A
4. Identification of System: Core Spray, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Re placement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Lisega UTC 2886020 N/A 1-1403-1 N/A Replaceme_.t. No

7. Description of Work: Replaced snubber.

8, Tests Conducted: Hydrostatic E] Pneumatic El Nominal Operating Pressure El Exempt Z Other E] Pressure _ psi Test Temp. - 'F 9, Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 9" .Jv-e' , 20ate iefor Ownetis lesigneeTitle I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period iq r'" %, to 1' r"'.' %\ , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ V_ _ _ _ ___ Commissions N rs-1 hIP iL ,,i VosSignature National Board. State. Province. and Endorsements Date o, 3ut- 20 %k Date I' 20 '.

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/30/20 i1 4300 Winfield Road Sheet: I of I Warrenville, It. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-079 WO: 1277438-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Core Spray, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Lisega UTC 2886021 N/A 1-1403-2 N/A Replacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic E] Pneumatic El Nominal Operating Pressure El Exempt Z Other F] Pressure _ psi Test Temp. - F
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed NDFte* -Date JVt,

__________,-._,.r 2011 V(j 4wne&r or Ownets0Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period j?' fm , to I*q I,,, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI, By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______________ Commissions Nf1"ns Ai *, L zn.

Invectors Signature National Board, State, Province. and Endorsements Date 1,Jut- 20 "

Date I 20 -

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/201 I 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-080 WO: 1277439-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Recirculation System, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Coipnonents Repaired or Replaced, and Re placement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

S_.nubber Lisega UTC 2851172 N/A 1-0201-M45 N/A Replacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic El Pneumatic E] Nominal Operating Pressure El Exempt Z Other r] Pressure __ psi Test Temp._ OF
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed . W OIner "V 4P. ,. , Owner's Desirgnk~e, Title 5.,-,"

or: I Date Jv4-e. 1.1 201).

CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period lot,, 0 to 17 I'M 1 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ __,,_ _ _ _ Commissions AJR13,115 A N II LZIII I -. inspectors signature National Board, State, Province, and Endorsements Date /q Joo 20  !*

Date I vp 20 11

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/6/2011 4300 Winfield Road Sheet: I of I Warrenville, Ii. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-081 WO: 1277440-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Recirculation System, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Re placement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Lisega UTC 2879678 N/A 1-0201 -F46 N/A Replacement No

7. Description of Work: Replaced snubber.
8. Tests Conducted: Hydrostatic F1 Pneumatic ED Nominal Operating Pressure El Exempt Z Other E] Pressure _ psi Test Temp. OF
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed V* OxnerL or 4"I-, Ud*signek, or"Ownet's ptv,%Title-,yst I Date I1 2J0 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford. Connecticut have inspected the components described in this Owner's Report during the period i6 pt I to -4 r"'4 1 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _ _ Commissions ttitls-t A )J1 iLz-f ignature I~ National Board, Slate, Province, and Endorsements DIff.. N'Jv" 20 "

flfttf~ J~ JOM 20 "

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 6/3/2011 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-093 WO: 1261768-02 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 2
5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N-416-3
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Relief Valve Enertech UTC 2848748 N/A 1-1001- !25B N/A Replacement No

7. Description of Work: Replaced relief valve.
8. Tests Conducted: Hydrostatic F1 Pneumatic El Nominal Operating Pressure [ Exempt El Other El Pressure __ psi Test Temp._ 'F
9. Remarks: None.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed " ga P-0^ 5v-c- t eDate \JVf - 20 t V OMner or Owntr's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period C.'v I'I, - to Z rh') 11 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_____ Commissions mg go 5 A ri iL2T' In. t ors Signature National Board, State, Provihce, and Endorsements Date P-5,3*u 20 I*

Date I .1w.'20 hl

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/14/11 4300 Winfield Road Sheet: 1 of 1 p Warrenville, I1.60555 Unit: 1 2.Plant: Quad Cities Generating Station Program No.: 10-097 WO: 1252124-02 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of Systemý Reactor, Class 1
5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Summer 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Rod Nova UTC 2877063 N/A 1-0201 N/A Replacement NHo Nut Nova UTC 2877403 N/A 1-0201 N/A Replacement No

7. Description of Work: Replaced bolting.

Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure [ Exempt El W Other nl Pressure __ psi Test Temp. - 'F

9. Remarks: Performed VT-I on bolting.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp .N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed V'

, eogV41, Pro% 5ser" 10wfer or Owd'er" Desigr~e, TitleI Date kJl )& 20 1(

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois., and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period !zrr-A,- to I J.,- I , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section X1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_Commissions Prit -s AA, ,_ zL k satre National Board, State, Province. and Endorsements Alhte 19 .VL- 20 0 F,

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/15/11 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-098 WO: 122674 1-1 1 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North- Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Reactor Recirulation, Class I
5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Com ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Lisega UTC 2879676 N/A 1-0202-A48 N/A Replacement No Load Pin Bergen-Power UTC 2773162 N/A 1-0202-A48 N/A Replacement No

7. Description of Work: Replaced snubber and load pin.
8. Tests Conducted: Hydrostatic r] Pneumatic r-1 Nominal Operating Pressure El Exempt 2 Other E Pressure _ psi Test Temp. - F
9. Remarks: Performed VT-3 on replaced snubber.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed M . Ff-o,, Svtyvr Date - 20' 20 11 V (wneror Owner's Designed!, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period f64 Ik to zt MN 11 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described inthis Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I- igaeatial Commissions od State, ,

Inmpectors signature National Board. Statre,Pnwvince,andEndorsements Date Iq, *\,u*. "20 I*

Date 1,~ vi- 20 11

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/15/11 4300 Winfield Road Sheet: I of 3 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-100 thru 10-127 WO: 1287161 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Control Rod Drive, Class I
5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Co ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

See Attachment A

7. Description of Work: Replaced Control Rod Drives and bolting in accordance with the W.O.
8. Tests Conducted: Hydrostatic L Pneumatic El Nominal Operating Pressure [ Exempt [

Other E] Pressure __ psi Test Temp. - 'F

9. Remarks: None.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ,vg,-

Tit le,-, Date July 1O 20 II V, Dwnd" or Owvner"s Designedl Title' CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Ir I, -. to zz N,,t t, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______________ Commissions rg Otis ANt it- -,.

V Inspectors Signature National Board, State, Province, and Endorsements Date "z.x _,. 20 11 Date ~ 20

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT (Supplement)

As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/15/I1 4300 Winfield Road Sheet: 2 of 3 Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-100 thru 10-127 WO: 1287161 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Control Rod Drive, Class 1
5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A Attachment A Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Control Rod Drive GE Nuclear S/N: 6571 N/A 1-0300-02-35 N/A Replacement No Enery Control Rod Drive GE Nuclear S/N: A4585 N/A 1-0300-10-11 N/A Replacement No Enery__.

Control Rod Drive GE Nuclear S/N: 9130 N/A 1-0300-14-31 N/A Replacement No Enery_ __

Control Rod Drive GE Nuclear S/N: 657C N/A 1-0300-18-11 N/A Replacement No Energ,_

Control Rod Drive GE Nuclear S/N: A1032 N/A 1-0300-18-43 N/A Replacement No Enery Control Rod Drive GE Nuclear S/N: 620 N/A 1-0300-22-07 N/A Replacement No Energ._

Control Rod Drive GE Nuclear S/N: A8959 N/A 1-0300-22-11 N/A Replacement No Ener.v -_ _

Control Rod Drive GE Nuclear S/N: A8953 N/A 1-0300-22-47 N/A Replacement No Ener.U Control Rod Drive GE Nuclear S/N: A8561 N/A 1-0300-26-31 N/A Replacement No Ener._

Control Rod Drive GE Nuclear S/N: 7886 N/A 1-0300-10-15 N/A Replacement No Energy Control Rod Drive GE Nuclear S/N: 9368 N/A 1-0300-30-27 N/A Replacement No Energ.y Control Rod Drive GE Nuclear S/N: A8961. N/A 1-0300-30-51 N/A Replacement No EneryMU,_

Control Rod Drive GE Nuclear S/N: 7908 N/A 1-0300-34-15 N/A Replacement No Energy.

Control Rod Drive GE Nuclear S/N: A2118 N/A 1-0300-10-31 N/A Replacement No Energy I I _ I 1_

Control Rod Drive GE Nuclear S/N: 7594 N/A 1-0300-42-07 N/A Replacement No Energ I I I

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT (Supplement)

As Required by the Provisions of ASME Code Section XI

!. Owner: Exelon Generation Company, LLC Date: 7/15/11 4300 Winfield Road Sheet: 3 of 3 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-100 thru 10-127 WO: 1287161 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Control Rod Drive, Class 1
5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A Attachment A Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Control Rod Drive GE Nuclear S/N: A9067 N/A 1-0300-46-51 N/A Replacement No Ener_

Control Rod Drive GE Nuclear S/N: A9278 N/A 1-0300-50-39 N/A Replacement No Ener_.

Control Rod Drive GE Nuclear S/N: A8357 N/A 1-0300-54-19 N/A Replacement No Ener_,__

Control Rod Drive GE Nuclear S/N: A9716 N/A 1-0300-54-35 N/A Replacement No Enermu_

Control Rod Drive GE Nuclear S/N: A9050 N/A 1-0300-54-39 N/A Replacement No Enerm Control Rod Drive GE Nuclear S/N: A8979 N/A 1-0300-22-23 N/A Replacement No Energy Control Rod Drive GE Nuclear S/N: A9009 N/A 1-0300-26-19 N/A Replacement No Ener__y_

Control Rod Drive GE Nuclear S/N: 5286 N/A 1-0300-30-07 N/A Replacement No Enerm.,u Control Rod Drive GE Nuclear S/N: 8113 N/A 1-0300-30-15 N/A Replacement No EnerZy Control Rod Drive GE Nuclear S/N: A5286 N/A 1-0300-38-15 N/A Replacement No Energy Control Rod Drive GE Nuclear S/N: 733C N/A 1-0300-46-27 N/A Replacement NMo Ener_,_

Control Rod Drive GE Nuclear S/N: 977 N/A 1-0300-50-19 N/A Replacement No EnerUv I____ ______ ________ I________

Control Rod Drive GE Nuclear S/N: 50 N/A 1-0300-54-23 N/A Replacement No Ener I I

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/14/11 4300 Winfield Road Sheet: 1of I Warrenville, I1.60555 Unit: 1 2.Plant: Quad Cities Generating Station Program No.: 10-130 WO: 799592-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Re placement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Bonnet Crane UTC 2883348 N/A 1-1001-50 N/A Replaced No

7. Description of Work: Replaced Bonnet.
8. Tests Conducted: Hydrostatic El Pneumatic DJ Nominal Operating Pressure [ Exempt [

Other 0 Pressure _ psi Test Temp. - IF

9. Remarks: Performed VT-3 on internal of valve.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed (-,"ýr . / p* i Sýyr -Date - *J '0 I9) 20 1 "Vl qwnerofOwner'§ DisigneefTlitie I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 1 mb* t to ?-4 A , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___________________________________________Commissions 1 5N . o Inspectors, Signature National Board, State.Province, and Endorsements IDate I* .]*,* 20 )*

Date 13JI'llu 20 J,

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/14/11 4300 Winfield Road Sheet: 1 of I Warrenville, 11. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-131 WO: 1267203-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System- Core Spray, Class 2
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N-416-3 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Valve Crane UTC 2877071 N/A 1-1402-38B N/A Replacement No Coupling Consolidated UTC 2874597 N/A I-1402-38B N/A Replacement No Pipe Consolidated UTC 2878723 N/A I- 1402-38B N/A Replacement No

7. Description of Work: Replaced valve, coupling, and pipe.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Z Exempt El Other FE Pressure __ psi Test Temp. °F
9. Remarks: None.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed rrsb,.e

, ,iDate 1 Ij1 20 1 V Ownerlor Owntr'2f Designie, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 1a m, i to ZS ,-wi, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ Z__ _ _ _Commissions if 13% 1,b N iz-,

"--Inspectors.Signature National Board. State, Province, and Endorsements Date 'o i. 20 *'

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 5/2/2001 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 11-001 WO:P.O.458819R IN199151 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC 29306 Expiration Date: N/A
4. Identification of System: Main Steam, Class 1
5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Rlacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Main Steam Safety Consolidated BK6251 N/A UTC 2065654 N/A Repair No Valve Safety Valve Div. Replacement

7. Description of Work: Replaced Nozzle.
8. Tests Conducted: Hydrostatic U] Pneumatic Ii Nominal Operating Pressure E] Exempt 0 Other E] Pressure _ psi Test Temp. 'F
9. Remarks: Pressure test to be performed post-installation.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 Aop B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed V 5¢P",

tie,*,',F Owrklr or O~aner's De[signe~e, Title "

Date W C4 20]

0 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period iZ -*A" t, to Cr,, .,, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

= a Commissions,11 'LsPts itUL.',

Inspernors Signature National Board, State, Province, and Endorsements Date ,( t,*,, 20 o*

Date ~ t~-wt 20 ft

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

i. Owner: Exelon Generation Company, LLC Date: 5/24/2011 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 11-003 WO: P.O. 467994 RIN 197271 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Wyle Laboratories Authorization No.: None 7800 Highwav 20 West. Huntsville. AL Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class I
5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Snubber Lisega UTC 2873603 N/A 61300/52 N/A Repair/ No I_ I___

__ 2876031 _ I_ I_ _ Replacement

7. Description of Work: Replaced threaded head assembly and cylinder.
8. Tests Conducted: Hydrostatic El Pneumatic [I Nominal Operating Pressure E] Exempt Z Other E] Pressure __ psi Test Temp. - 'F
9. Remarks: Functional test. VT-3 to be performed post-installation.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed awnAA "J

P .

Of/vnet"or-Owner'siDesignee, Ti t

,, r.Ds

-Date Meay ' 20t0 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,Jb,-', to Z3 m- " , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____C t er, o mmissions MStaI)A* , S e Pt, InpcosSgaure National Board, State. Province. and Endorsements Date Z-S,,,M, 20 "J Date ~ 20

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 5/6/2011 4300 Winfield Road Sheet: I of I Warrenville, Ii. 60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 11-012 WO: P.O. 462858 RIN 199186 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC 29306 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: ASME Section III Edition: 1968 Addenda: Winter 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Rplacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Target Rock Valve Target Rock 171 N/A UTC 2874531 N/A Repair / No Replacement

7. Description of Work: Drilled two thermowells and replaced I bonnet stud and nut.
8. Tests Conducted: Hydrostatic E] Pneumatic El Nominal Operating Pressure El Exempt ED Other [] Pressure __ psi Test Temp. OF
9. Remarks: An internal VT-3 examination performed. VT-I perfomed on new bolting. Pressure test to be performed post-installation.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed l"* , 2 Peg.' SVR v4-r Date M& V 04, 20 i/

+0erOwner's l3esignee,Flitle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z,/_,hit 0, to 6r%,p , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____Commissions r-Ntt ,)J, t(LZ?-

I spe nature National Board, State, Province, and Endorsements Date (/*'* 20 fl Date C 20 "

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 5/6/2011 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 11-013 WO: P.O. 472689 RIN 199185 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC 29306 Expiration Date: N/A
4. Identification of System: Main Steam., Class I
5. (a) Applicable Construction Code: ASME Section III Edition: 1968 Addenda: Winter 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Co ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Target Rock Valve Target Rock 120 N/A UTC 2883135 N/A Repair / No I I_ Replacement

7. Description of Work: Drilled two thermowells.
8. Tests Conducted: Hydrostatic El Pneumatic F1 Nominal Operating Pressure El Exempt M Other E] Pressure _ psi Test Temp. _ F
9. Remarks: An internal VT-3 examination performed. Pressure test to be performed post-installation.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed (" / t o ig m4,$-/,upV-e s,,54 Date L4A 0(0 20 t V " (Jwner or Ownef s D~esignee, Ilritte ',

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period - ,-.t i to 4 r"at I , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report inaccordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ " __ _ _____,_//_ __ _ _ Commissions Nam-75,Al f,-Z,,

J Inspectors Signature National Board, State, Province, and Endorsements 20 ii Date 4 20 t,

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

i. Owner: Exelon Generation Company, LLC Date: 5/5/2011 4300 Winfield Road Sheet: I of 1 Warrenville, Ii. 60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 11-016 WO: P.O. 463081 RIN 199288 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC 29306 Expiration Date: N/A
4. Identification of System: Main Steam, Class 1
5. (a) Applicable Construction Code: ASME Section III Edition: 1980 Addenda: Winter 1980 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Co ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Electromatic Relief NWS BK7062 N/A UTC 2071151 N/A Repair / No Valve Technologies Replacement

7. Description of Work: Removal of cracked tack welds.
8. Tests Conducted: Hydrostatic E0 Pneumatic El Nominal Operating Pressure El Exempt 0 Other El Pressure _ psi Test Temp. - F
9. Remarks: An internal VT-3 examination performed. Pressure test to be performed post-installation.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed I f!ýtj P ln Apv&ir S'

V, Owdfer ot Owner's -Designee, Title" Date MA O' 20 11 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period L/AN?,, to 4 f'" V , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____ Commissions P' IK130 A,N, I u-J, ,

lnspeCtor.*ignaaure National Board, State. Province, and Endorsements Date d *.*v 20 11 Date~ ,"ý 20.

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI L.Owner: Exelon Generation Company, LLC Date: 5/5/2011 4300 Winfield Road Sheet: I of t Warrenville, 11. 60555 Unit: 0 2,Plant: Quad Cities Generating Station Program No.: 11-017 WO: P.O. 463081 RIN 199288 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC 29306 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: ASME Section III Edition: 1980 Addenda: Winter 1980 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Co ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Electromatic Relief NWS BX00290 N/A UTC 2664333 N/A Repair / No Valve Technologies Replacement

7. Description of Work: Removal of cracked tack welds.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt 0 Other El Pressure _ psi Test Temp. - F
9. Remarks: An internal VT-3 examination performed. Pressure test to be performed post-installation.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed *1 O4[e Ow¢, Vr&4 5nq-,gi

  • 'we'gD[ignee,*ritle '
  • Date _ _ _

I _ _ 2011 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i MQ-'\ to 6 i'w , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _ _ _ _ _ Commissions M4't3Cls J,j- -Lzzn Inspectors Signature National Board. State, Province, and Endorsements Dale o/ ,* 20 'I Date b--,i 20 //

W

'n ý 171, , . -1 , 3 11 1 , , , ý - ý, ý FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XII

1. Owner: Exelon Generation Company, LLC Date: 7/15/11 4300 Winfield Road Sheet: I of 1 Warrenville, I1.60555 Unit: I E2.Plant: Quad Cities Generating Station Program No.: 11-024.11-026 WO: 1226741-01, -64 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Reactor Recirculation, Class 1
5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N-652-1
6. Identification of Com ponents Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Stud Flowserve UTC 2884077, N/A 1-0202-A N/A Replacement No 1___ 1__ 2884951 1 0

7. Description of Work: Machined casing and replaced bolting during pump refurbishment.
8. Tests Conducted: Hydrostatic F1 Pneumatic El Nominal Operating Pressure [D Exempt El Other F1 Pressure __ psi Test Temp. - `F
9. Remarks: Performed VT-I on bolting.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed e', wnAs'e , t i" n. Tit' -D ate JV,1,I1J 1 2011 V - "9w nieror Olwnef 's,,Designef, Titlef CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by IHSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ;NM'S4 o to ZJ., I , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ _Commissions ('Biis 3A 0. IL-z27,

'-- Inspectors Signature National Board, State, Province, and Endorsements lte Z1 JuL- 20 _ _

F

FORM NIS-:2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/14/11 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 11-025 WO: 1433281-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Reactor Recirulation, Class 1
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Rplacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Flange Consolidated UTC 2706397 N/A 1-0202-A N/A Replacement No Rod Accutech UTC 2697699 N/A 1-0202-A N/A Replacement No Nu.t Nova UTC 2869861 N/A 1-0202-A N/A Replacement No

7. Description of Work: Replaced flange and bolting.

Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure [ Exempt Ii Other El Pressure __ psi Test Temp._ IF

9. Remarks: Performed VT- I on bolting.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed C, V j O'ndn's I Owfier or , "Vv,,-,r*

Designee, Title DateIl 20 iL CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,'mm J, to tr f.q, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.


, 1ý Commissions pails A P, iLzz National Board. State, Province, and Endorsements I Inspectors Signature I -te 20- JVL 20 .'*

20 1,

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/11/11 4300 Winfield Road Sheet: I of 1 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station ProgramNo.: 11-029 WO: 1280161-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Main Steam, Class I
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1955 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Component Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Plu & Stem Assembly Crane UTC 2847831 N/A 1-0203-2B N/A Replacement No Stud Crane UTC 2049802, 2678117 N/A 1-0203-2B N/A Replacement No Stud Various UTC 2678120, 2846278 N/A 1-0203-2B N/A Replacement No Nu_ Crane UTC 2002067, 2400252 N/A 1-0203-2B N/A Replacement No

7. Description of Work: Replaced plug/stem and bolting.
8. Tests Conducted: Hydrostatic 17 Pneumatic [] Nominal Operating Pressure [ Exempt El Other -- Pressure __ psi Test Temp. - F
9. Remarks: Performed VT-I on bolting and LLRT.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed VA Ov~her iý o'r,IOwfier's Defigfiee, P.-aok TAle 5yW.ýe I Date 'v[! 1

,0 20J4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ;i mm It to 11 .'wl I, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report inaccordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ V__ Commissions wi? lrvl rP, IL?,-t Vf nspetors Signature National Board, State. Province, and Endorsements Date zo AVL_ 20 '1 Date 20 20 It

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/14/11 4300 Winfield Road Sheet: 1of 1 Warrenville, 11. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 11-035 WO: 97104789-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Reactor Recirculation, Class 1
5. (a) Applicable Construction Code: ASME Section UB3 1.1 Edition: 1968/1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Rod Nova UTC 2887507 N/A 1-0202-4A N/A Replacement No Nut Nova UTC 2887508 N/A 1-0202-4A N/A Replacement No

7. Description of Work: Replaced bolting.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure [ Exempt fl Other rI Pressure __ psi Test Temp. - 'F
9. Remarks: Performed VT-I on bolting and VT-3 on valve internals.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 Aprp B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed , V -- " OwnAer*

Ownfer,5or OwVTi OwtfertDesignte, Titree Date A 5 20t1 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ZZ r',,* I to 30 /11M a , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions N- 13tlS At t ,-. z.

nature National Board. State, Province, and Endorsements IDate 1

Date

)*"d,*t-

.'L20 20 b, t

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 7/15/11 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 11-036 WO: 367241-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
4. Identification of System: Reactor Recirculation, Class 1
5. (a) Applicable Construction Code: ASME Section 11B3 1.1 Edition: 1968/1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Rod Nova UTC 2887507 N/A 1-0202-4B N/A Replacement No Nut Nova UTC 2887508 N/A 1-0202-4B N/A Replacement No

7. Description of Work: Replaced bolting.
8. Tests Conducted: Hydrostatic El Pneumatic 0l Nominal Operating Pressure Z Exempt E]

Other El Pressure __ psi Test Temp. - 'F

9. Remarks: Performed VT- I on bolting and VT-3 on valve internals.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed cf .- 6"o rrato 5 ,- Date ,JvlV 1i 2011 V I Owfier or O0nef's Designee, Title ,f CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,8 Ml P to 29 M)-,, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ _ _ _ _ _ _ _ _ Commissions s Ao , it., -1,

-&In pectors Signature National Board. State, Prnvince, and Endormments Date IW" , V. 20 )1

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/15/11 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 11-037 WO: 367241-25 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symb l'Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Residual Heat Removal, Class I
5. (a) Applicable Construction Code: AISC SCM Edition: 7th 1970 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Rod Nova UTC 2812640 N/A M-994D-23 N/A Replacement No Nut Nova UTC 2847044 N/A M-994D-23 N/A Replacement No Flat Bar Various UTC 2863778 N/A M-994D-23 N/A Replacement No

7. Description of Work: Installed bolted connections on support diagonal brace.
8. Tests Conducted: Hydrostatic fl Pneumatic El Nominal Operating Pressure F1 Exempt L Other Z Pressure __ psi Test Temp. - 'F
9. Remarks: Performed VT-3 on support.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed . JVI1 I* 2011 V Owner or Owrfer"t Desigitee, TitleI CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period V *h v to 7-1mi'i 1' , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property a loss of any kind arising from or connected with this inspection.

_ _7_ _ _ _Commissions tAs ,. ti it.zt%

-- lupectors Signature National Board. State, Province, and Endorsements Date 13 3111. 20 tt D~,re 1?20 lt

FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI

1. Owner: Exelon Generation Company, LLC Date: 7/14/11 4300 Winfield Road Sheet: I of 1 Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 11-038 WO: 1440147-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp: None

3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
4. Identification of System: Core Spray, Class 2
5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
6. Identification of Components Repaired or Replaced, and Replacement Components:

Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)

Support N/A N/A N/A M- 1610-06 N/A N/A No

7. Description of Work: Adjusted support.
8. Tests Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure [ Exempt [

Other Z Pressure __ psi Test Temp._ 'F

9. Remarks: Performed VT-3 on support.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed C , *-*,v , .- Date %Ji 1,* 20 It V¶ Pwneeor Owner's Dsignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period *7r-' I, to zrm-. I, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damae or a ss of any kind arising from or connected with this inspection.

_ __ _ _ _ Commissions riisns-s t 2Z Inspectors Signature National Board, State, PMvince, and Endorsements Date 20 Atll 20 P_