SVP-13-044, Day Post Outage ISI Letter
ML13211A347 | |
Person / Time | |
---|---|
Site: | Quad Cities |
Issue date: | 07/05/2013 |
From: | Handley T Exelon Generation Co |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
SVP-13-044 | |
Download: ML13211A347 (78) | |
Text
Exeton Generatki iOCFR50.55a SVP-13-044 July 5, 2013 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Quad Cities Nuclear Power Station Unit I Renewed Facility Operating License No. DPR-29 NRC Docket NM.0-254
Subject:
90-Day Post Outage ISI Letter Enclosed Is the Quad Cities Nuclear Power Station Unit I Post-Outage (90 day) Summary Report for Inservice Inspection exam-ations and Repair/Replacement activities conducted from the May 2011 refueling outage through the March 2013 refueling outage. This report is due on the first business day 90 days after the end of the Unit I Q1R22 refueling outage, which Is July 8fh, 2013. This report documents examinations performed during the third period of the fourth Inspection Interval.
This report is submitted in accordance with the requirements of ASME Section X1, Article IWA-O00, "Requirements."
Ifthere are any questions or comments concerning this letter, please refer them to Mr. Wally Beck, Regulatory Assurance Manager, at (309) 227-2800.
- Sinerely, Tim "Oxdley Site Vice President Quad Cities Nuclear Power Station
Attachment:
Quad Cities Nuclear Power Station - Unit I Post Outage (90 day) Summary Report cc: Regional Administrator - NRC Region III NRC Senior Resident Inspector - Quad Cities Nuclear Power Station qk4L
ATTACHMENT Quad Cities Nuclear Power Station-Unit 1 Post Outage (90 day) Summary Report
Quad Cities Nuclear Power Station - Unit 1 Post Outage (90 Day) Summary Report Refueling Outage Q 1R22 Outage Start Date: March 11, 2013 Outage End Date: April 8, 2013 Commercial Service Date: February 18, 1973 22710 206th Avenue North, Cordova, IL 61242 Exelon Generation Company, L.L.C.
300 Exelon Way Kennett Square, PA 19348 Prepared by: I6 V/ f)/-?
-Nicholas Johnson (ISI Engineer)
Reviewed by: /(, 7,( 1 6/2 / .13 Chris Hebel (Reactor and Internals Engineer5 Reviewed by: , 4)4, -2 Gary Knaprp4Snubber Engineer) 6 Reviewed by: 1<0-/-/-
David'Kunzmann (Pressure Test Engineer)
Reviewed by:
- q. ° O-z,-z' Brian Hub:nIg(Repair/Replacement Engineer)
Approved by: -"7/ _.i*L9t 44 Mathew Rice (Manager Program Enginee ng)
//3
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table of Contents
1.0 INTRODUCTION
.............................................................................................................................................. 3 1,1. OUTAGE, PERIOD AND INTERVAL START AND END DATES ................................................................... 3 1,2. EXAMINATION PROGRAM REQUIREMENTS ............................................................................................ 3 2.0 NIS-1 FORM ....................................................................................................................................................... 4 3.0 ABSTRACT OF EXAMINATIONS, CONDITIONS NOTED AND CORRECTIVE MEASURES .......... 6 3.1. SECTION XI EXAMINATIONS
SUMMARY
.............................................................................................. 6 3.2. BWRVIP-75/GENERIc LETTER 88-01 .................................................................................................. 6 3.3. INVESSEL INSPECTIONS (IV I) .................................................................................................................... 7 Table 3.1-1 Quad Cities Unit 1 ASME Section XI Outage Summary (4 th interval)................. 9 Table 3.1-1A Additional Exams in Accordance with IWF-2430 (4 th interval) ........................... 11 Table 3.1-1B Quad Cities Unit I - ASME Section XI Limited Coverage Summary (4 'h interval)......... 12 Table 3.1-2 Quad Cities Unit I Pressure Testing Summary (4 th interval) Third Period............. 12 Table 3.1-3 Quad Cities Unit I Snubber Functional Tests (4 th interval).................................. 13 Table 3.1-4 Quad Cities Unit I Conditions Noted DuringISI on ASME Code Components and CorrectiveActions (4 th interval)................................................................................ 14 Table 3.2-1 Quad Cities Unit 1 BWRVIP-75-A/GL 88-01 Outage Summary............................... 15 Table 3.3 Quad Cities Unit 1 Number and Percentageof Examinations Completed (4'h interval)..16 4.0 REPAIR / REPLACEMENT
SUMMARY
................................................................................................. 17 4 .1. N IS -2 IN DEX ........................................................................................................................................... 17 Table 4.1-1 Quad Cities Unit 1 NIS-2 List . .................................................................... 17 4 .2 . N IS -2 FO RMS.......................................................................................................................................... 19 2 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 2 0 6 th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 1.0 Introduction 1.1. Outage, Period and Interval Start and End Dates This Inservice Inspection Summary Report encompasses examinations and repairs performed from June 10, 2011 through April 8, 2013 during the fourth ten-year interval third inspection period. This most recent refueling outage was the 2 2 nd refueling outage for Quad Cities Nuclear Power Station Unit 1 and is the second outage for this unit during the third inspection period. The outage started March 11, 2013 and was completed April 8, 2013 when the unit returned to service.
Tests, examinations, and repair/replacement activities associated with American Society of Mechanical Engineers (ASME) Code,Section XI were witnessed or otherwise verified by the Authorized Nuclear Inservice Inspectors. Non-ASME Section XI or augmented examinations that were not witnessed or otherwise verified by the Authorized Nuclear Inservice Inspectors and are marked "Not Required" or "N/A" on the applicable examination reports. The Authorized Nuclear Inservice Inspectors are inspectors of the Hartford Steam Boiler Inspection & Insurance Company of Connecticut (HSB-CT). The HSB-CT Regional Office is located at 2443 Warrenville Road Suite 500, Lisle, Illinois, 60532-1098.
1.2. Examination Program Requirements The examination requirements of ASME Boiler and Pressure Vessel Code,Section XI, Division 1, "Rules for Inservice Inspection of Nuclear Power Plant Components", 1995 Edition through 1996 Addenda were implemented for Class 1, 2 and 3 components except where written relief has been granted by the NRC. Written relief, in the form of Relief Request 14R-02 approving Risk Informed Inservice Inspection (RISI) as an inspection program alternative for Code Categories B-F, B-J, C-F-1 and C-F-2, was utilized during Q1R22. The ultrasonic examination volumes for RISI components were increased from the Section XI requirements to meet the RISI Program.
The ultrasonic examination requirements of ASME Boiler and Pressure Vessel Code,Section XI, Appendix VIII, 1995 Edition with Addenda through 1996, as required by 10 CFR 50.55a, "Codes and Standards", and amended by the Federal Register Notice 64 FR 51370 dated September 22, 1999 is executed through the Performance Demonstration Initiative (PDI) Program according to the schedule defined in 10 CFR 50.55a(g)(6)(ii)(C),
for wrought austenitic piping welds, ferritic piping welds, bolts/studs, reactor vessel welds, nozzle to vessel welds, nozzle inside radius sections and full structural overlaid wrought austenitic piping welds.
3 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 2.0 NIS-1 Form FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1. Owner Exelon Generation Company, L.L.C., 300 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner)
- 2. Plant Quad Cities Nuclear Power Station, 22710 2 0 6 'hAvenue North, Cordova, IL 61242 (Name and Address of Plant)
- 3. Plant Unit One 4. Owner Certificate of Authorization (if required) N/A
- 5. Commercial Service Date 2/18/73 6. National Board Number for Unit N/A
- 7. Components Inspected Component or Manufacturer Manufacturer State or National Appurtenance Or Installer or Installer Province No. Board No.
Serial No.
Reactor Pressure Babcock & Wilcox 610-0122-51-52 B0075000 N/A Vessel Company Reactor Recirculation Dravo Corp. N/A - See Table 3.1-1 N/A N/A Core Spray Grinnell N/A - See Table 3.1-1 N/A N/A Feedwater Grinnell N/A - See Table 3.1-1 N/A N/A Main Steam Grinnell N/A - See Table 3.1-1 N/A N/A Residual Heat Grinnell N/A - See Table 3.1-1 N/A N/A Removal Control Rod Drive Grinnell N/A - See Table 3.1-1 N/A N/A High Pressure Coolant Grinnell N/A - See Table 3.1-1 N/A N/A Injection Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11/2 in.,
(2) information in items 1 through 6 on this report is included on each sheet unless they are coded N/A, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
4 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 2 0 6th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 FORM NIS-1 (Back)
- 8. Examination Dates: 6/11/11 to 4/8/13
- 9. Inspection Period Identification: 3Yd Period - From 3/1/10 to 4/8/13 for the 4th Interval
- 10. Inspection Interval Identification: 4th Interval - From 3/10/03 to 4/8/13
- 11. Applicable Edition of Section XI 1995 Addenda 1996
- 12. Date/Revision of Inspection Plan: 12/6/12 Revision 9 (4th Interval)
- 13. Abstract of Examination and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Section 3.0 and Tables 3.1-1, 3.1-1A, 3.1-1B, 3.1-2, 3.1-3, 3.1-4, 3.2-1, and 3.3.
- 14. Abstract of Results of Examinations and Tests. See Section 3.0 and Tables 3.1-1 3.1-1A, 3.1-1B, 3.1-2, 3.1-3, 3.1-4, 3.2-1, and 3.3
- 15. Abstract of Corrective Measures. See Section 3.0 and Table 3.1-4.
We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the ASME Code,Section XI.
Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date .. t,,e- Z5_ 20 ,.3 Signed Exelon Corporation By Owner CERTIFICATE OF INSERVICE INSPECTION I, the under signed, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois, and employed by Hartford Steam Boiler of Connecticut of Hartford, Connecticut have inspected the components described in the Owner's Report during the period 6/11/11 To 4/8/13 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
/ Commissions N9[R 1-1s p* m I I L"Lzx
-Inspector's Signature National Board, State, Province, and Endorsements Date ZG 3Qos 20 I1 5 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206"h Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 3.0 Abstract of Examinations, Conditions Noted and Corrective Measures 3.1. Section XI Examinations Summary A combination of ultrasonic (UT), liquid penetrant (PT), magnetic particle (MT) and visual (VT) testing were performed prior to and during the 2 2 nd refueling outage on ISI Program components. Examinations were performed by General Electric Hitachi (GEH), URS Quality Programs, and Exelon Nuclear personnel. Volumetric and surface examinations were compared with the recorded results of previous examinations for applicable Class 1, 2 and RISI components. ISI inspections comprised of 31 volumetric (17 were RISI, Category R-A welds), 3 surface examinations and 59 visual examinations were performed on Class 1, 2 and RISI components. Of these 59 visual examinations, 41 were additional inspections due to IWF-2430(a) through (d) scope expansion requirements. There were 2 volumetric examinations that did not meet coverage requirements of ASME Section XI Code (i.e.
greater than 90 percent of the specified examination volume) during Q1R22 (Table 3. 1-IB).
Code cases used for ISI or Repair/Replacement activities are listed in the ISI Program Plan.
Pressure testing VT-2 examinations not related to repair/replacement activities are documented in Table 3.1-2, "Quad Cities Unit 1 Pressure Testing Summary (4 th Interval)
Third Period". The Class I and 2 Vessel Leakage Tests were performed in accordance with the 1995 Edition 1996 Addenda of the ASME Code and applicable Relief Requests as listed in Table 3.1-2 for the third period of the fourth Interval.
Exelon personnel performed functional tests on a total of twenty-seven (27) snubbers for operability per the Service Life Monitoring/Failure Trending Sample and ASME OM Code Subsection ISTD. Thirteen (13) snubbers were selected for the 10% sample group testing with the remaining fourteen (14) being tested for Service Life Monitoring. Fifteen (15) of the twenty-seven (27) snubbers were ASME Section XI Code designated. In addition, twenty-four (24) replacement snubbers were tested and installed in accordance with a planned snubber replacement plan which is part of the Service Life Monitoring strategy. Of the fifty-one (51) snubbers tested, none (0) were found to be unacceptable for continued operation. Snubber testing activities are summarized in Table 3.1-3, "Quad Cities Unit 1 Snubber Functional Tests (4 th Interval)".
Table 3.1-4, "Quad Cities Unit 1 Conditions Noted During ISI on ASME Code Components and Corrective Actions (4th interval)" summarizes the conditions noted during the examinations and corrective measures taken prior to returning the unit to service.
Table 3.3, "Quad Cities Unit 1 Number and Percentage of Examinations Completed (4th Interval)" identifies number and percentage of examinations completed in the fourth interval.
3.2. BWRVIP-75-A/Generic Letter 88-01 Augmented examinations required by Generic Letter 88-01, "NRC Position on Intergranular Stress Corrosion Cracking (IGSCC) in BWR Austentic Stainless Steel Piping" and BWRVIP-75-A, "BWR Vessel and Internals Project Technical Bases for Revisions to 6 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit I Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova,IL 61242 Generic Letter 88-01 Inspection Schedules", were implemented in this outage (Table 3.2-1).
Seven (7) Category C Welds (susceptible to IGSCC but mitigated by stress improvement) were examined. One (1) Category D Weld (weld made with susceptible material that have not been treated with an IGSCC remedy and in which cracks have not yet been reported) was examined. Two (2) Category E Welds (cracked weldments that have been mitigated by a weld overlay) were examined. No relevant indications were found during these examinations. This is consistent with previous examination results.
3.3. In-Vessel Inspections (IVI)
Relief Request I4R-15 was approved as an alternative to Category B-N-I and B-N-2 requirements. Related B-N-I and B-N-2 exams performed during Q1R22 included:
- Visual inspections of the Steam Dryer wall support lugs for ongoing wear (VT-1, VT-3)
- Visual inspections of Jet Pump (JP) Primary Riser Brace Leaf to Vessel Pad welds RB- I on Jet Pump Riser 9/10 and 19/20 (EVT-1, VT-3)
- Visual inspections of Core Shroud Support welds H8, H9, H10, and H12 located in the Lower Plenum area in accordance with BWRVIP-47-A and BWRVIP-38 (EVT-1, VT-3)
- Visual inspections of CRD Stub Tube welds located in the Lower Plenum area in accordance with BWRVIP-47-A (VT-3)
- Visual inspections of Core Shroud Vertical welds in accordance with BWRVIP-76-A (EVT-1)
- Visual inspections of Core Shroud Repair hardware in accordance with BWRVIP-76-A and BWRVIP letter 2011 -011 (EVT-1)
- Visual inspections of Instrument Nozzle Upper and Lower RPV interior welds per programmatic requirements (EVT-1 and VT-3)
- Visual inspections of Moisture Separator Guide Rod Support Bracket Attachment Upper Weld at 200 Degrees due to programmatic requirements (VT-I and VT-3)
Augmented examinations were performed to implement additional BWRVIP requirements in accordance with the guidelines listed:
" Visual inspections of Jet Pump Assemblies in accordance with BWRVIP-41 Revision 3 (EVT- 1)
" Visual inspections of Core Spray piping welds in accordance with BWRVIP-18-RI-A (EVT-1)
" Visual inspections of the Steam Dryer in accordance with BWRVIP- 139-A and GE recommendations and guidance provided in programmatic requirements per General Visual exam techniques (GVT)
" Visual inspections of the Jet Pump Riser RS-2 weld on Jet Pump 13/14 prior to weld repair in accordance with BWRVIP-41 Revision 3 (EVT-1)
" Visual inspections of Top Guide Rim weld in accordance with BWRVIP-26-A (EVT-1)
" Visual inspections of IRM 14 and SRM 22 Dry Tubes in accordance with BWRVIP-47-A (EVT-1)
" Visual and Ultrasonic Testing inspections of 48 Shroud Head Bolts in accordance with SIL 433 and 650 (VT-3 and UT) 7 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206"h Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Visual inspections of Cast Austenitic Stainless Steel (CASS) components per License Renewal commitments (EVT-1)
All eight Feedwater Sparger End Bracket pins were inspected during Q 1R22 as a follow-up to minor bracket wear from the pins identified during previous outages. The pinheads are wearing into the bracket hardware due to flow-induced vibration. No new or additional wear was noted in Q IR22. These indications are documented in IR 1488750 and evaluated as acceptable under EC 392703.
Core Spray piping welds were visually examined (19 visual exams). In this population were 3 welds with previously identified indications. Each of these indications was examined in Q1R22 with no apparent change in size. No additional indications were identified in the rest of the population. These indications are documented in IR 1489974 and evaluated under EC 392703.
Indications were observed in HAZ of Jet Pump 13/14 Riser pipe RS-2 weld during Q IR21 (2011). The weld was replaced with a mechanical repair clamp in Q1R22 under EC 385225 No changes was observed in the RS-2 indication from Q1R21 to Q1R22. The indications are documented in IR 1488705 and evaluated for continued service under EC 392703.
Multiple indications (gouges and rub marks) were identified on all four of the Steam Dryer wall support lugs. These indications were previously observed in Q1R21.
A comparison of the inspection results from Q 1R21 to Q IR22 found no apparent change to the previous indications and no new indications were identified. These indications are documented in IR 1488697 and evaluated for continued service under EC 392703 Indications were observed in HAZ of the Top Guide Rim weld. A total of 20 cell locations were inspected, with recordable indications observed in 6 of these cell locations. The indications are documented in IR 1490590 and evaluated for continued service under EC 392937.
Quad Cities will continue to monitor these conditions in accordance with the Reactor Internals Program.
8 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 2 0 6th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-1 Quad Cities Unit 1 ASMIE Section XI Outagie Summary ( 4 th Interval)
Report Number Component Class Category Item Inspection Results 13-VT3-123 0200-W-104 A&B I F-A F1.10 VT-3 RI/Acceptable by repair 13-VT3-077 0328-M-201 2 F-A F1.20 VT-3 NRI 13-VT3-I 11 1003A-M-205 2 F-A F1.40 VT-3 NRI 13-VT3-113 1003A-W-201 2 F-A F1.40 VT-3 NRI QIR22-003 1003A-W-201A 2 C-C C3.10 SURF NRI 13-VT3-115 1006C-W-201 2 F-A F1.20 VT-3 NRI QIR22-004 1010-1.1 2 R-A RI.11 UT-E NRI 13-VT3-110 1016A-M-202 2 F-A F1.40 VT-3 NRI Q 1R22-005 1016C-4 2 R-A R1.20 UT-E NRI Q1 R22-006 1016C-5 2 R-A R1.20 UT-E NRI Q1R22-007 1018C-2 2 R-A R1.20 UT-E NRI Q 1R22-008 1024A-2 2 R-A R 1.11 UT-E NRI 13-VT3-112 1024A-W-201 2 F-A F1.20 VT-3 NRI QIR22-009 1025-36 2 R-A RI.20 UT-E NRI Q1R22-010 1025-46 2 R-A R1.20 UT-E NRI Q1R22-011 1025-9 2 R-A R1.20 UT-E Acceptable 13-VT3-067 1025-M-206 2 F-A F1.20 VT-3 NRI 13-VT3-119 1025-M-207 2 F-A F1.20 VT-3 Acceptable Q1R22-012 I0BD-FII I R-A RI.I1 UT-E NRI Q1R22-014 10BD-F9 I R-A R1.11 UT-E Acceptable QIR22-015 10BD-S10 I R-A RI.I1 UT-E NRI Q1R22-016 10BD-S2 1 R-A RI I1 UT-E NRI QIR22-017 10BD-S3 I R-A RI.11 UT-E NRI QIR22-018 10BD-S4 I R-A RI.ll UT-E NRI QI R22-019 10BD-S8 I R-A RI.I1 UT-E NRI 13-VT3-125 1404-M-104 I F-A F1.10 VT-3 NRI Q1R22-020 1A-1003A-3 2 C-A C1.10 UT NRI Q 1R22-021 IA-1003A-4 2 C-A C1.20 UT NRI 13-VT3-124 2305-W-102 I F-A FI.10 VT-3 NRI 13-VT3-109 2325-M-206 2 F-A F1.20 VT-3 NRI Q1R22-022 23S-F1 I R-A R1.20 UT-E NRI 13-VT3-122 3001D-M-101.2 1 F-A F1.10 VT-3 NRI 13-VT3-121 3001D-W-102 1 F-A F1.10 VT-3 NRI 13-VT3-142 3001 D-W-103 A&B I F-A FI.10 VT-3 NRI QIR22-023 CLOSURE BUSHING I B-G-1 B6.50 VT-1 NRI QIR22-024 CLOSURE NUTS I B-G-I B6.10 VT-1 NRI QI R22-025 CLOSURE STUDS I B-G-I B6.20 UT NRI QIR22-026 CLOSURE WASHERS I B-G-I B6.50 VT-I NRI Q1R22-028 LIGAMENTS I B-G-1 B6.40 UT NRI 9 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-1 (continued)
Quad Cities Unit 1 ASME Section XI Outage Scope (4 th Interval)
Report Number Component Class Category Item Inspection Results Q1R22-029 NI0-F! 1 R-A R1.20 UT-E NRI Q1R22-030 N8A-FI RHRHX 2 C-B C2.31 SURF NRI QIR22-031 N8A-F2 RHRHX 2 C-B C2.31 SURF NRI QIR22-032 RPV-THDW 1 B-A BI.21 UT NRI QIR22-033 RPV-THMS-0 1 B-A B1.22 UT NRI Q 1R22-034 RPV-THMS-120 I B-A B1.22 UT NRI QIR22-035 RPV-THMS-180 I B-A B1.22 UT NRI Q1R22-036 RPV-THMS-240 1 B-A B 1.22 UT NRI QIR22-037 RPV-THMS-300 I B-A B1.22 UT NRI QIR22-038 RPV-THMS-60 I B-A BI.22 UT NRI 10 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-1A Additional Exams in Accordance with IWF-2430 (4 th Interval)
Report Number Component Class Category Item Inspection Results 13-VT3-165 0200-M-170 1 F-A F1.10 VT-3 NRI 13-VT3-135 0200-W-119 A&B 1 F-A F1.10 VT-3 NRI 13-VT3-127 0200-W-124 A&B 1 F-A F1.10 VT-3 RI/acceptable by repair 13-VT3-134 0200-W-138 A&B 1 F-A F1.10 VT-3 NRI 13-VT3-126 0200-W-105 A&B 1 F-A F1.10 VT-3 RI/acceptable by repair 13-VT3-139 0200-M-142 1 F-A F1.10 VT-3 NRI 13-VT3-140 0200-M-146 1 F-A F1.10 VT-3 NRI 13-VT3-141 0200-M-148 1 F-A F1.10 VT-3 NRI 13-VT3-143 0200-M-150 1 F-A F1.10 VT-3 NRI 13-VT3-144 0200-M-153 1 F-A F1.10 VT-3 NRI 13-VT3-136 0200-M-155 1 F-A F1.10 VT-3 NRI 13-VT3-137 0200-M-158 1 F-A F1.10 VT-3 NRI 13-VT3-160 0200-W-169 1 F-A F1.10 VT-3 NRI 13-VT3-163 0200-M-171 1 F-A F1.10 VT-3 NRI 13-VT3-161 0200-M-172 1 F-A F1.10 VT-3 NRI 13-VT3-162 0200-M-173 1 F-A F1.10 VT-3 NRI 13-VT3-166 0200-M-174 1 F-A F1.10 VT-3 NRI 13-VT3-167 0200-M-175 1 F-A F1.10 VT-3 NRI 13-VT3-150 0200-W-124.1 1 F-A F1.10 VT-3 NRI 13-VT3-168 0200-W-143 1 F-A F1.10 VT-3 NRI 13-VT3-169 0200-W-154 1 F-A F1.10 VT-3 NRI 13-VT3-145 0209A-M-102 1 F-A F1.10 VT-3 NRI 13-VT3-146 0209A-M-103 1 F-A F1.10 VT-3 NRI 13-VT3-147 0209B-M-101 1 F-A F1.10 VT-3 NRI 13-VT3-151 0209B-M-102 1 F-A F1.10 VT-3 NRI 13-VT3-128 0200-W-113 A&B 1 F-A F1.10 VT-3 NRI 13-VT3-129 0200-W-117 A&B 1 F-A F1.10 VT-3 NRI 13-VT3-130 0200-W-133 A&B 1 F-A F1.10 VT-3 NRI 13-VT3-131 0200-W-137 A&B 1 F-A F1.10 VT-3 NRI 13-VT3-132 0204A-M-101 1 F-A F1.10 VT-3 NRI 13-VT3-133 0204B-M-101 1 F-A F1.10 VT-3 RI/acceptable by repair 13-VT3-152 0200-W-1 07A&B 1 F-A F1.40 VT-3 RI/acceptable by repair 13-VT3-154 0200-W-108 A&B 1 F-A F1.40 VT-3 NRI 13-VT3-156 0200-W-109 A&B 1 F-A F1.40 VT-3 NRI 13-VT3-157 0200-W-1 27 A&B 1 F-A F1.40 VT-3 NRI 13-VT3-158 0200-W-1 28 A&B 1 F-A F1.40 VT-3 RI/acceptable by repair 13-VT3-159 0200-W-1 29 A&B 1 F-A F1.40 VT-3 RI/acceptable by repair 13-VT3-172 1025-M-103 1 F-A F1.10 VT-3 NRI 13-VT3-173 1202-M-111 1 F-A F1.10 VT-3 NRI 13-VT3-170 1012B-W-104 1 F-A F1.10 VT-3 RI/acceptable by repair 13-VT3-171 1012A-W-104 1 F-A F1.10 VT-3 RI/acceptable by repair 11 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206"h Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-1B Quad Cities Unit 1 ASME Section XI Limited Coverage Summary (4 th Interval)
Report Number Component Class Category Item Inspection ASME % Coverage Q 1R22-029 N10-F1 I R-A R1.20 UT-E 85.9%
Table 3.1-2 Quad Cities Unit 1 Pressure Testing Summary (4 th Interval)
Third Period Component Component Category Inspection Work Relief Remarks Class CategoryInspectionOrder(s)
.~~* - %. - -1 - 1 Request Remarks RX Class I B-P Visual, VT-2 01444754 14R-07 Class I piping boundary System leak test.
CS (A) Class 2 C-H Visual, VT-2 01379586 N/A CS - A loop system leak test CS (B)' Class 2 C-H Visual. VT-2 01379585 & N/A CS - B loop & ECCS Fill RHR (A)' Class 2 C-H Visual, VT-2 01379909 01379580& N/A RHR RHR (B)'I 01379579 systemLoop A system leakage test leak test
________________ __________ 013799080 N/A RHR Loop B system leak test RHR (B) ' Class 2 C-H Visual, VT-2 01379579 & RHR Lo~op B system leak test 01379908 N/A HPCIP Class 2 C-H Visual, VT-2 01379571 N/A HPCI system leak test 01379582 &
SBLC' Class 2 C-H Visual. VT-2 01379583 & N/A SBLC system leakage test 01547364 ECCS Class 2 C-H Visual, VT-2 01379584 N/A ECCS Suction piping system leak test
'Note: Q 1R22 is the second of two outages during the third period for Unit I which ended April 8, 2013. The above CS, RHR, HPCI and SBLC inspections address remaining portions of the Class boundaries. The balance of these systems were previously inspected and reported on the Q IR21 Post Outage (90 Day) Summary Report.
12 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-3 Quad Cities Unit 1 Snubber Functional Tests ( 4 tb Interval)
Snubber EPN / IS[ Number Class Category Item Snubber/ nspection ate Results Number Installed Snubber Tested 10% Samole Groun 1-003 114043/ 1 F-A FI.10 Removed & Re-lnstalled Fr 03/17/13 Pass 1404-W-103 A&B 1-0202-A ll Removed Fr 03/16/13 Pass 0200-W-109 A&B Installed Fr 03/06/13 Pass 1-0202-B12 / Removed Fr 03/16/13 Pass 0200-W- 127 A&B Installed FT 03/08/13 Pass
!1-025 1-0202-B25 / 1 F-A F!I.40 Removed Fr 03/14/13 Pass 0200-M-132 Installed Fr 03/06/13 Pass 1-1070-34/ Removed Fr 03/04/13 Pass NA Installed Fr 03/01/13 Pass 1-035 1-1070-35/ NA NA NA Removed FT 03/05/13 Pass NA Installed Fr 03/01/13 Pass 1-062 1-3019-B62 / NA NA NAIstle Removed FT 03/19/13 Pass NA Installed Fr 03/15/13 Pass 1-065 1-3019-E65 / N A N Removed Fr 03/19/13 Pass NA Installed Fr 03/06/13 Pass 1-3001-C70 / Removed Fr 03/13/13 Pass 3001C-M-101.2 Installed Fr 03/08/13 Pass 1-3019-D78 / Removed FT 03/18/13 Pass NA Installed FT 03/06/13 Pass 1-1025-79 / Removed Fr 03/08/13 Pass 1025-M-206 Installed Fr 03/06/13 Pass 1-0328-128 / 2 F-A F120 Removed Fr 03/05/13 Pass 1-128 0328-M-201 Installed FT 03/01/13 Pass 1-129 1-0328-129 / 2 F-A F1.20 Removed FT 03/04/13 Pass 0320-M-201 Installed Fr 03/01/13 Pass Service Life Monitoring Group 1-004 1-1404-4/ 1 F-A F1.10 Removed & Re-Installed Fr 03/17/13 Pass 1404-W- 103 A&B 1-0203-28 / Removed Fr 03/13/13 Pass 3035A-M-l01 Installed FT 03/07/13 Pass 1-0300-0033 / Removed Fr 03/13/13 Pass NA Installed FT 03/06/13 Pass 1-048 1-0202-A48 / F-A FI.10 Removed & Re-Installed FT 03/14/13 Pass 0200-M-170 1-050 1-3001 -A50 / NA NA NA Removed Fr 03/18/13 Pass NA Installed Fr 03/08/13 Pass 1-3019-A60 / Removed Fr 03/18/13 Pass NA Installed Fr 03/07/13 Pass 1-3001 -B63 / Removed FT 03/14/13 Pass 3001B-M-101.1 Installed FT 03/07/13 Pass 1-066 1-3019-E66/ NA NA NA Removed FT 03/19/13 Pass NA Installed FT 03/07/13 Pass 1-3001-C71 / Removed Fr 03/16/13 Pass 3001C-M-102.1 Installed FT 03/08/13 Pass 1-3019-C72 / Removed FT 03/17/13 Pass NA Installed Fr 03/07/13 Pass 1-1025-83 / Removed FT 03/08/13 Pass 1025-M-225 Installed Fr 03/06/13 Pass 1-1025-86/ Removed Fr 03/08/13 Pass 1025-W-211 Installed Fr 03/06/13 Pass 1-118 1-7509-118 / NA NA NAIntle Removed FT 03/05/13 Pass NA Installed Fr 03/01/13 Pass 1-1025-122 / Removed FT 03/16/13 Pass 1025-M-101 A&B Installed FT 03/20/13 Pass 13 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206'h Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.1-4 Quad Cities Unit 1 Conditions Noted During ISI on ASME Code Components and Corrective Actions (4 th Interval)
Component ID Description / Resolution Pressure Test During the Unit I Class I System Leakage Test the listed components were identified to be leaking.
Corrective actions were taken as follows:
Corrective actions completed 1-0200 - Under Vessel Flange bolted Engineering evaluation (EC # 393061) was performed (as permitted by Relief Request 14R-07) on CRD connections under vessel flange bolted connections and determined bolting and leakage were acceptable.
RX Head vent piping class 2 socket weld Weld repair -Work Order 01626729 REPAIR LEAK IN RX VESSEL HEAD VENT PIPING.
line 1-0215-2"-B Visual Inspections Hanger conditions found from original scope and additional exams:
- 1. 0200-W- 104 A&B 1. IRs 1488312 and 1487809 were written for this hanger which was part of the original ISI scope. Indications consisted of loose nuts on the clamp and missing and a cracked non-structural lugs on the hanger. The hanger was restored to acceptable design condition and then re-inspected with no recordable indications.
- 2. 0200-W-124A&B 2. IR 1488463 was written for this hanger which was part of the 1" level expansion per IWF-2430(a). Indications consisted of loose nuts on the clamp and missing non-structural lugs on the hanger. The hanger was restored to acceptable design condition and then re-inspected with no recordable indications.
- 3. 0200-W-105A&B 3. IR 1488444 was written for this hanger which was part of the I" level expansion per IWF-2430(a). Indications consisted of a loose nut on the hanger. The hanger was restored to acceptable design condition and then re-inspected with no recordable indications.
- 4. 0204B-M-101 4. IR 1488729 was written for this hanger which was part of the 2"d level expansion per IWF-2430(b). Indications consisted of a loose bolting on the hanger. The hanger was restored to acceptable design condition and then re-inspected with no recordable indications.
- 5. 0200-W-107A&B 5. IR 1489610 was written for this hanger which was part of the 3Yd level expansion per IWF-2430(c). Indications consisted of a loose nut on the hanger. The hanger was restored to acceptable design condition and then re-inspected with no recordable indications.
- 6. 0200-W-128A&B 6. IR 1489490 was written for this hanger which was part of the 3"d level expansion per IWF-2430(c). Indications consisted of a loose nut and an installed locking pin. The hanger was restored to acceptable design condition and then re-inspected with no recordable indications.
- 7. 0200-W-129A&B 7. IR 1489491 was written for this hanger which was part of the 3"d level expansion per IWF-2430(c). Indications consisted of a loose nut on the hanger. The hanger was restored to acceptable design condition and then re-inspected with no recordable indications.
- 8. 1012B-W-104 8. IR 1490241 was written for this hanger which was part of the 3"' level expansion per IWF-2430(c). Indications consisted of a loose nut on the hanger. The hanger was restored to acceptable design condition and then re-inspected with no recordable indications.
- 9. 1012A-W-104 9. IR 1490228 was written for this hanger which was part of the 3Yd level expansion per IWF-2430(c). Indications consisted of loose nuts on the hanger. The hanger was restored to acceptable design condition and then re-inspected with no recordable indications.
14 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.2-1 Quad Cities Unit 1 BWRVIP-75-A/GL 88-01 Outage Summary Pre/Post Report Number Component Class Outage Inspection Results Category QIR22-012 I0BD-FI I' I C UT-E NRI Q 1R22-014 IOBD-F9 1 I C UT-E Acceptable QIR22-015 I0BD-S10' 1 C UT-E NRI QI R22-016 IOBD-S21 I C UT-E NRI QIR22-017 IOBD-S3' I C UT-E NRI Q1R22-018 IOBD-S41 1 C UT-E NRI QIR22-019 IOBD-S8' I C UT-E NRI QIR22-013 10BD-F5 1 D UT NRI Q1R22-001 02AS-S12 I E UT NRI Q 1R22-002 02L-S4 I E UT NRI Note: Weld is credited towards ASME Section Xl Risk Informed ISI Program population.
15 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 3.3 Quad Cities Unit 1 Number and Percentage of Examinations Completed ( 4 th Interval)
Category Exams Completed in Q1R22 Exams Completed to Date Total Exams in the Interval Percentage Complete for Interval B-A 4 7 29 29 100 B-D 9 1 46 46 100 B-G-I' 1 8 8 100 B-G-2 2 0 33 33 100 B-K 0 11 11 100 B-L-25 0 1 1 100 B-M-I 0 1 1 100 B-M-2 5 1 12 12 100 B-N-I N/A N/A N/A N/A B-N-2s N/A N/A N/A N/A 4
B-0 0 2 2 100 3
B-P N/A N/A N/A N/A C-A 2 4 4 100 C-B 7 2 14 14 100 C-C 1 11 11 100 C-H 3 N/A N/A N/A N/A F-A6 15 94 94 100 R-A1° 16 114 114 100
'Note: Category B-G- I contains reactor vessel studs and nuts. 1/3 of the reactor vessel studs, nuts, washers and ligaments are examined each period. Since the component number is repeated in this category, each period may result in greater than the limiting percentage of 2 exams.
Note: B-G-2 category includes bolted connections when components are opened as well as in place under tension.
3 4Note: Category B-P and C-H exams are pressure tests tracked under Table 3.1-2.
Note: Exam Category B-A and B-O are scheduled to coincide with previous interval to maintain ten year interval between exams and are 5 performed in accordance with IOCFR50.55a Period completion percentage does not apply.
Note: Categories B-L-2, and B-M-2 are inspected and credited under the Repair/Replacement Program only when the component is 6 disassembled. Only one of each type of valve and pump are required to be examined.
Note: Only 69 total exams are required to meet combined Class I and 2 requirements for F-A category, however additional exams were scheduled to better distribute exams between systems and based on discovery of indications on Unit 2. Previous counts included the 7 scope expansion of several Class 1 hangers which artificially raised the inspection numbers for code credit.
Note: Only 12 components are required to be examined in Category C-B, however several are 100% obstructed and are required to be examined every period by VT-2 in accordance with Item Number C2.33. Therefore, percentage completion for the interval by item number does not apply.
8 Note: B-N-I and B-N-2 Category Exams are credited by the performance of the BWRVIP program in accordance with Relief Request 14R-15.
9 Note: Category B-D exam population has been reduced as a result of Relief Request 14R-17.
'(Note: Category R-A exam population from the 2005B RISI Model requires 105 components be inspected in the 10-year interval. 114 Components are scheduled for examination to improve distribution by system. The distribution changes across the interval based on Risk Model updates.
16 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206'h Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 4.0 Repair / Replacement Summary 4.1 NIS-2 Index Table 4.1-1 Quad Cities Unit 1 NIS-2 List Program Number Work Request Component EPN ASME XI Number or Class Purchase Order 05-054 739200-01 0-Spare-H15 2 10-061 1257055-01 1-0203-3B 1 10-062 1079828-01 1-0203-3E 1 11-039 1441240-01 1-1012B-H50 1 11-129 & 12-016 1246003-03, 02 1-1106-A 2 12-001 1361548-01 1-2301-53 2 12-022 1334063-01 1-2301-23 2 12-093 1437531-01 1-0203-1A 1 12-102 PO 00492237 0-Spare (SIN 780) 1 12-103 PO 00492237 0-Spare (S/N 61346/14) 1 12-116 1486937-02 Rx HeadNent Bolting 1 12-118 thru 12-137 1560413 Various Control Rod Drives 1 12-138 1461996-01 1-3001-B63 1 12-139 1461992-01 1-0203-28 1 12-140 1461999-01 1-3001-C70 1 12-141 1462000-01 1-3001-C71 1 12-142 1461988-01 1-1025-86 2 12-143 1461987-01 1-1025-83 2 12-144 1461981-01 1-0202-B25 1 12-145 1461979-01 1-0202-All 1 12-146 1461980-01 1-0202-B12 1 12-147 1461986-01 1-1025-79 2 12-148 1461991-01 1-0328-129 2 12-149 1461990-01 1-0328-128 2 12-150 1439881-01 1-0203-3D 1 12-151 1439882-01 1-0203-3C 1 12-152 1470273-01 1-0203-3B 1 12-153 1439883-01 1-0203-4C 1 12-154 1439884-01 1-0203-4D 1 12-155 1439885-01 1-0203-4G 1 12-156 1439886-01 1-0203-4H 1 12-157 1472713-01 1-0203-3A 1 12-187 1583204-05 1-1402-57 2 12-190 1539077-01 Spare disc and trim set 1 12-192 PO 488210 Target Rock 198 1 12-194 PO 424879 ERV BY94636 1 12-195 PO 499002 Target Rock 172 1 13-001 Rev. 1 PO 496783 ERV BK7060 1 13-004 1448076-01 1-1003-A 2 13-005 PO 488211 MSSV BK6295 1 13-006 880894-30 1-2305-10" 2 17 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 Table 4.1-1 Quad Cities Unit 1 NIS-2 List Program Number Work Request Component EPN ASME XI Number or Class Purchase Order 13-014 1616873-04 Spare MSIV disc 1 13-017 1623414-01 1-0300-42-11 1 13-019 1462003-1 1-1025-122 1 13-022 1624044-01 1-0220-58B 1 13-024 1623835-01 0200-W-104A/B 1 13-025 1624129-01 0200-W-105A/B 1 13-026 1624130-01 0200-W-124A/B 1 13-027 1624353-01 0204B-M-101 1 13-028 1624817-01 0200-W-107AIB 1 13-029 1624818-01 0200-W-129A/B 1 13-030 1624819-01 0200-W-128A/B 1 13-031 1625361-01 1012B-W-104 1 13-032 1625360-01 1012A-W-1 04 1 13-033 1626729-01 1-0215-2"-B 2 18 of 19
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 1 Kennett Square, PA 19348 22710 2 0 6th Avenue North, Commercial Service Date February 18, 1973 Cordova, IL 61242 4.2 NIS-2 Forms (Attached) 19 of 19
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 4/18/2013 4300 Winfield Road Sheet: I of _1 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 05-054 WO: 739200-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Residual Heat Removal, Class 2
- 5. (a) Applicable Construction Code: Section VIII Edition: 1968 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Pipe Consolidated UTC 2678985 N/A Spare N/A Repair No
- 7. Description of Work: Refurbished the floating head for replacement on I-1003A.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure 5 Exempt 0 Other E . Pressure __ psi Test Temp. - 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -i Ai/-o ., &( Date /3 20 /
Owner or Owner't DesignetrTitle '- 4 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ;'FA"j- Oa to iq t,,tt 13 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ ,.__ _ _ _ _ Commissions MNR 13115 Ak) I IL2z11 V Inspectors Signature National Board. State, Province, and Endorsements Date 10 MA'lri _m /X flare~~ 0o 13i~
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 3/15/2013 4300 Winfield Road Sheet: I of I1 Warrenville, 11.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-061 WO: 1257055-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1995 Addenda: 1996 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Valve Dresser Industries S/N BX00290 N/A 1-0203-3B. N/A Replacement No Stud Nova UTC 2847665 N/A 1-0203-3B N/A Reolacement No Hydranut Nova UTC 2883910, N/A 1-0203-3B N/A Replacement No 2727471I, 2733672 1 1
- 7. Description of Work: Replaced valve and bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic 0l Nominal Operating Pressure ED Exempt E]
Other Fl Pressure __ psi Test Temp. - F
- 9. Remarks: Performed VT-I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -Axqk )4 AC Date / 0 Owner or Ownet's Designee. Tle J CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period r3 puf 41 to /PJL It' . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ __ __Commissions &I'IflSA N 11_1111 Vipcurs Signature -National Board. State, Prvince. and Endor.ements Flnto 1"7 APP "20 IZ Dlate 1-7 APR 20l 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 3/15/2013 4300 Winfield Road Sheet: I of /
Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 10-062 WO: 1079828-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1995 Addenda: 1996 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Valve Dresser Industries SIN BY94637 N/A I-0203-3E N/A Replacement No Stud Nova UTC 2841985 N/A 1-0203-3E N/A Replacement No Hydranut Nova UTC 2885666 N/A l-0203-3E N/A Replacement No
- 7. Description of Work: Replaced valve and bolting.
- 8. Tests Conducted: Hydrostatic [] Pneumatic E] Nominal Operating Pressure [ Exempt El Other El Pressure _ psi Test Temp. - 'F
- 9. Remarks: Performed VT-I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed __,._,____Owner 6r Ownefs,__
Designee, Tile _., e__ Date __20 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period N it' to J*,u-.t . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____Commissions N9g13fl15 Atu ILZi.
I npectors Signature National Board. State. Province, and Endorsements Date 1*7 MIL 20 I*
20 11
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 8/19/11 4300 Winfield Road Sheet: I of I Warrenville, Ii. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 11-039 WO: 1441240-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Residual Heat Removal, Class 1
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N-649
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or N/A I- 1012B-H50 N/A Replaced No Nut Nova UTC 2737674
- 7. Description of Work: Replaced missing nut.
- 8. Tests Conducted: Hydrostatic El Pneumatic Dl Nominal Operating Pressure El Exempt 19 Other Fl Pressure __ psi Test Temp. - F
- 9. Remarks: Performed VT-3 on support.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code .Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A
-2 e.,zt.J--D 2
G , i/ (* ** Date____________________
Signed Owne o0 Owner or Owner's Designee, Title ,
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois - and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period IL. M-.' to Z7- M&4 II , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_____Commissions 09 i3ris A It- -,7, 1 Iiature National Board, State. Pmvince. and Endorsements Date Z"l A06- 20 It Date 2M ~U& 20 Ii
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 5/7/2013 4300 Winfield Road Sheet: I of 1 Warrenville. 11.60555 Unit: I 2.Plant: Quad Cities Generating Station ProgramNo.: 11-129& 12-016 WO: 1246003-02&-03 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No.. Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Standby Liquid Control, Class 2
- 5. (a) Applicable Construction Code: USAS B3 1. 1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Co ponents Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Trigger Assembly Mirion UTC 2915104 N/A I-I 106A N/A Replacement No Technologies
__ _ I Valve'PuI Conax Buffalo UTC 2916593 N/A -I I106A N/A Replacement No
- 7. Description of Work: Replaced trigger assembly and valve plug.
- 8. Tests Conducted: Hydrostatic [] Pneumatic [] Nominal Operating Pressure El Exempt 0 Other El Pressure __ psi Test Temp. 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 7 Owe orVOwner'I esA Date 20/t Owner or Owner's Designee, Title' -
CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois . and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z( t'P~*- A to ZZ-. MAiz 13 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions la If*1-- *) I IL 7L211 I eCr Signature National Board. State. Province. and Endorsements Date /* r"w't 20 I,.7>
Date %- M~-0~ 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 5/3/2012 4300 Winfield Road Sheet: I of I_
Warrenville. I1. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-001 WO: 1361548-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No., Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 12710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: High Pressure Coolant Injection, Class 2
- 5. (a) Applicable Construction Code: USAS B31. I/Section I Edition: 1967/1965 Addenda: N/A/Summer 1966 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Relief Valve Dresser UTC 2851750 N/A 1-2301-53 N/A Replacement No
- 7. Description of Work: Replaced relief valve.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure 23 Exempt El Other Fl Pressure _ psi Test Temp. - 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code.Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 4_q. , A-/Le,-Date Owner or O~wner's Dlesignee, Title
/3 20 13 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period n mvtI's to Z.) Mt. 13 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____Commissions
/ WPCh io~~trsl signatulre
'N8 Ix'iS A W I Naliolnad*lll KH-rdSu 11.-Z. Ik Pwvn cem'andl Endior~ments Date ý. mpýl I c~ 20 Ks
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 4/9/2013 4300 Winfield Road Sheet: I of .1 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-022 WO: 1334063-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: High Pressure Coolant Iniection, Class 2
- 5. (a) Applicable Construction Code: USAS B3 1.1 / Section 1 Edition: 1967 / 1965 Addenda: N/A / Summer 1966 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Relief Valve Dresser UTC 2870567 N/A 1-2301-23 N/A Replacement No
- 7. Description of Work: Replaced relief valve.
- 8. Tests Conducted: Hydrostatic El Pneumatic [I Nominal Operating Pressure ED Exempt [
Other [ Pressure __ psi Test Temp. __ 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code.Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed --*-.oe-ai ,,c *41ar Date 4/0 201-f Owner or Owner's Wesignee, Titie-1 /
CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois . and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 13 r-'. k' to ISruXm. - , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ __ __Commissions MR Q3CTS AaN t1-'7k7i uspectors signature National Board, State. Province. and Endorsments Date 15' AZ. 20 /
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT
.\s Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 4/18/2013 4300 Winfield Road Sheet: I of I1 Warrenville. 11. 60555 Unit: I
-.Plant: Quad Cities Generating Station Program No.: 12-093 WO: 1437531-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 12710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B3I. I Edition: 1955 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Coiponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Plug and Stem Crane-Aloyco Inc. UTC 2936995 N/__A 1-0203-IA N/A Replacement No Assembly
- 7. Description of Work: Replaced valve plug and stem assembly.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure E] Exempt 10 Other LI Pressure _ psi Test Temp. 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear [OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed i AI Date 20 /2 Owner or Owner's Desighee, Title,.)
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period , tPwVt 3 to 11 % - . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss ofany kind arising from or connected with this inspection.
4__ __ ___ __ ___- _ Commissions N8'l'T~i AN I IL-L7_II NI TtirsSignature National Board, Siate. Province. and Endorsm ents Date Z NIP. 20 13 Date ? r~'~ 20 ~3
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 3/25/2013 4300 Winfield Road Sheet: I of _I Warrenville. II. 60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 12-102 WO: P.O. 492237; RIN 214366 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Wyle Laboratories Authorization No.: None 7800 Highway 20 West, Huntsville, AL Expiration Date: N/A
- 4. Identification of System: Spare Snubber,
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Snubber PSA S/N 780 N/A N/A N/A Repair / No III __Replacement
- 7. Description of Work: Replaced spherical bearing.
- 8. Tests Conducted: Hydrostatic [] Pneumatic E- Nominal Operating Pressure [ Exempt [
Other F1 Pressure _ psi Test Temp._ 'F
- 9. Remarks: Functional test. VT-3 to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code .Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 4!L-,'Date I/1 20Q Owner or Owner's Designee, Title -J CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 'St ,et IZ to -P MRt IT , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASMIE Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__Commissions tJSIi'7_ AWt ýL. zt7t Inspectors Sienature National Board. State, Province. and Endorsements Dqte ['7 APf?- 20 *Z mt~ riA~f~ 20 t3
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 3/25/2013 4300 Winfield Road Sheet: I of .1 Warrenville. I1.60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 12-103 WO: P.O. 492237; RIN 214366 22710 206th Ave. North. Cordova. IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Wyle Laboratories Authorization No.: None 7800 Highway 20 West, Huntsville, AL Expiration Date: N/A
- 4. Identification of System: Spare Snubber, __
- 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 7. Description of Work: Replaced main cylinder, threaded head assembly, and cylinder tube.
- 8. Tests Conducted: Hydrostatic EL Pneumatic El Nominal Operating Pressure LI Exempt [
Other Ln Pressure __ psi Test Temp. - 'F
- 9. Remarks: Functional test. VT-3 to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -1722 - -V s-W Owner or Ovfner's Desionee, Title I(/,/-r Date U
/6" 20 45 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois . and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 31,.3,rx to Z3 MIXI? , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions NZl1317S A w i ltL'L-Lti
/ cors signature National Board. State, Prxvince, and Endorsements Date 17 -AP't 20 1.3 Date 17 Aj'r~ 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 6/12/2013 4300 Winfield Road Sheet: '1 of I Warrenville, I1. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-116 WO: 1486937-02 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor, Class 1
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Summer 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Rod Nova UTC 2922002 N/A 1-0201 N/A Replacement No Nut Chicago Bridge & UTC 2692427 N/A 1-0201 N/A Replacement No
_ _ _ _ Iron___
- 7. Description of Work: Replaced bolting.
- 8. Tests Conducted: Hydrostatic E] Pneumatic ] Nominal Operating Pressure Z Exempt E]
Other [ Pressure _ psi Test Temp._ 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear 10CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed0 ~/"12,6
!ý , Pf ,,'Date C / 220 Owner or OwneT DesignebD'itle ,..J 1i CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period -aF0 13 to 2i f,&P N's , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property daage or a ss of y kind arising from or connected with this inspection.
__ _ _ _ _Commissions \Z1t31i7. PýQ I JL- "L2ZII Irhpe. s Signature National Board, State, Province, and Endorsements Date 1"7*t* 20 1"3 Date 11 lU.- 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 5/15/2013 4300 Winfield Road Sheet: I of 3 Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-118 thru 12-137 WO: 1560413 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp: None 3, Work Performed by: Qtad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Control Rod Drive, Class 1
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
See Attachment A
- 7. Description of Work: Replaced Control Rod Drives and bolting in accordance with the W.O.
- 8. Tests Conducted: Hydrostatic E] Pneumatic E] Nominal Operating Pressure 12 Exempt [
Other rI Pressure __ psi Test Temp. 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code.Section XI Type of Code Symbol Stamp N/A- Exelon Nuclear I0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -,E 0 6-1611 f "
Date /i20 12 Owner or Owner's De'fignee. Title -
CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 17 MrA( 13 to "Z_rn- I" , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certiticate. neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damager a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ Commissions pN91IS IA)1 1L-ZZII or~s Signature Nmaala B.ard. Slate. Proince. andEndorsemeiit.s Mite 7'1 MO*' 20 t*
RiteZ~ f20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT (Supplement)
As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 5/15/2013 4300 Winfield Road Sheet: 2 of 3 Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 1'-118thru 12-137 WO: 1560413 22710 206th Ave. North. Cordova. IL 61242 Repair Organization P.O. No., Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 17710 206th Ave. North. Cordova. IL 6 1242 Expiration Date: N/A
- 4. Identification of System: Control Rod Drive, Class i
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A Attachment A Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Control Rod Drive GE Nuclear S/N: A6653 N/A 1-0300-30-07 N/A Replacement No ControlRodDrive_ GE Energy. _ _ A5266
_ _ N/_-30345_/_epaeet N Control Rod Drive GE Nuclear S/N: A5266 N/A 1-0300-34-5 i N/A Replacement No ControlRodDriveGENuclEnergy __2NA -3 30NAN Control Rod Drive GE Nuclear S/N: A9749 N/A 1-0300-34-59 N/A Replacement No
_ E nerMy.
Control Rod Drive GE Nuclear S/N: 216 N/A 1-0300-38-03 N/A Replacement No Energy Control Rod Drive GE Nuclear S/N: A4708 N/A 1-0300-38-3I N/A Replacement No Energy I I Control Rod Drive GE Nuclear S/N: A536 i N/A 1-0300-38-31 N/A Replacement No Control Rod Drive GE Nuclear S/N: A9046 N/A 1-0300-38-39 N/A Replacement No Energy Control Rod Drive GE Nuclear S/N: A9132 N/A 1-0300-38-43 N/A Replacement No Enery Control Rod Drive GE Nuclear S/N: 432 N/A 1-0300-42-51 N/A Replacement No Energy II Control Rod Drive GE Nuclear S/N; 78A94 N/A 1-0300-46-31 N/A Replacement No EnerIgy.
Control Rod Drive GE Nuclear S/N: A8744 N/A 1-0300-50-15 N/A Replacement No Energy Control Rod Drive GE Nuclear S/N: 7885 N/A 1-0300-50-23 N/A Replacement No Ener2g I Control Rod Drive GE Nuclear S/N: 1934 N/A 1-0300-54-15 N/A Replacement No
______ Energy
_ I __KO Control Rod Drive GE Nuclear S/N: 483A N/A 1-0300-06-43 N/A Replacement N__oo Energy _____________ _____________
Control Rod Drive GE Nuclear S/N: A9000 N/A 1-0300-10-47 N/_.A Replacement N__oo Energy
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT (Supplement)
As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/15/2013 4300 Winfield Road Sheet: 3 of 3 Warrenville. I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-118 thru 12-137 WO: 1560413 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Control Rod Drive, Class I
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A Attachment A Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Control Rod Drive GE Nuclear S/N: A2248 N/A 1-0300-10-51 N/A Replacement No Ener_.
Control Rod Drive GE Nuclear S/N: 9174 N/A 1-0300-14-19 N/A Replacement No
_Ener.
Control Rod Drive GE Nuclear S/N: 967 N/A 1-0300-22-35 N/A Replacement No EnerU Control Rod Drive GE Nuclear S/N: A9697 N/A 1-0300-26-51 N/A Replacement No Energy.
Control Rod Drive GE Nuclear S/N: A9080 N/A 1-0300-26-55 N/A Replacement No Cap Screws Nova UTC 2927898, N/A Cat ID 42416-1 N/A Replacement No 1 2822995 1
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 4/03/12013 4300 Winfield Road Sheet: I of I Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-138 WO: 1461996-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None
?'710 206th Ave. North. Cordova. IL 61?42 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class 1
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired. ASME Component IvMfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Snubber Lisega UTC 2916664 N/A 1-300 1-B63 N/A Replacement No
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic El Pneumatic EL Nominal Operating Pressure Ej Exempt [D Other F1 Pressure _ psi Test Temp. _ 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the niles of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed : a,# P',, 4 /40*s 6 *,- Date _ _ _ _'_ ' 20
- Owner or Ofner's De*,gnee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period VZAV,-r1 to 73 r--,A , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
u rnCommissions+/-,-t *3l1-. A N I IL.Z..t i mpeaors Signature National Board. State. Pnvince. ind Endor-ements Date i' A.P PR7 20
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 4/03/2013 4300 Winfield Road Sheet: I of 1 Warrenville. 11.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-139 WO: 1461992-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B3 I. 1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Snubber Liseoa USA Inc. UTC 2916657 N/A 1-0203-28 N/A Replacement No
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic El Pneumatic 0 Nominal Operating Pressure El Exempt 0 Other El Pressure __ psi Test Temp. - 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 4-4ve,, 47* .1, Date '/A 20'if Owner or Or/ner's Demnee, Title -,J .J CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 13 f"-,P.'M3 to tq r"t',5 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
ZCommissions P49 M IS A N k RLZZI i ClOs signalure National Board. State. Pnmvince. and Endorsements I I;11* I* 11*I I',-. L{0 I*
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 4/03/2013 4300 Winfield Road Sheet: I of _1 Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-140 WO: 1461999-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No., Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Ouad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class 1
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Snubber Liseva USA Inc. . UTC 2713291 N/A 1-3001-C70 N/A Replacement No
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic El Pneumatic 0l Nominal Operating Pressure El Exempt ED Other El Pressure __ psi Test Temp. 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code . Section Xt Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed A Ownerfor Owners 6'.
"/, Designee,.TVtlekA SA ý e,, Date 116 20/5 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period I! iW*a-&r to 14 rýA I - . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _Commissions 091311S A N J I tR-Zzt 1 *s, ct'tors Simnature National Bolard. State. Province, and Endorrsemenis Date 13 AP/. 20 1"
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 4/03/2013 4300 Winfield Road Sheet: I of I Warrenville, [1.60555 Unit: I
..Plant: Quad Cities Generating Station Program No.: 12-141 WO: 1462000-01 227 10 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of _Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Snubber Lisega UTC 2932768 N/A 1-3001-C71 N/A Replacement No
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic EI Pneumatic El Nominal Operating Pressure El Exempt G1 Other F1 Pressure __ psi Test Temp._ 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code.Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 Aop B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed , 6-' Wro -Date L/// 7 20 L..?
Owner or Owner's Deignee. Title J, CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7Z.AA- -- to I1 rmi'lt, , and state that to the best of my knowledge and belief. the owner has performed cxaminations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xl.
By signing this certificate. neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of ny kind arising from or connected with this inspection.
Commissions t.)ft A tN
- iS II,.zz.
ors Signature National Board. State, Province. and Endorsements Date 1I -,kPP- 20 \3
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 3/29/2013 4300 Winfield Road Sheet: I of I Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-142 WO: 1461988-01 22710 206th Ave. North. Cordova. IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Ouad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Residual Heat Removal, Class 2
- 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced. and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced. or Code No. Replacement Stamped kYes or No)
Snubber Pacific Scientific UTC 2916673 N/A 1-1025-86 N/A Replacement No Co._._.
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt [
Other El Pressure __ psi Test Temp.__ 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ý Owner "'ý ,
or OWner's ,,, tf Title Desifiee. ,, Date z111 20 /3 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7ZAut V? to Z11r,.*, r' . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xi.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage r a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ _ Commissions t'j&-,\is r 0 kt\L7.z-lt F '-nn.pectorsSignature National Board. State. Province. and Endorsements Date '1- -APIZ 20 13 Date l ~Pt 20 I
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 4/013/2013 4300 Winfield Road Sheet: I of /
Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-143 WO: 1461987-01 227-10 206th Ave. North, Cordova. IL 61242 Repair Organization P.O. No.. Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Residual Heat Removal, Class 2
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 7. Description of Work: Replaced snubber and taper pin.
- 8. Tests Conducted: Hydrostatic [] Pneumatic 11 Nominal Operating Pressure LI Exempt [
Other F1 Pressure __ psi Test Temp. __ 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code .Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed - Date 20 j Owner or Owner's Desighee, Title J ;J CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z7 F6' ix to 1M, ,'X , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ /
__ __/_ Commissions tPJ1r-15 A N t ILZtZ)
Inm~t Y rosSignature Nalional Board. S .ate, Pnrvince. and End,,r.ements Date I Y AII 20 1
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 4/03/2013 4300)Winfield Road Sheet: I of I Warrenville. 11.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-144 WO: 1461981-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor Recirculation, Class I
- 5. (a) Applicable Construction Code: USAS B3 I. I Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or I I_ I No)
Snubber Pacific Scientific UTC 2916656 N/A 1-0202-B25 N/A Replacement No Co....__.
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic E5 Pneumatic El Nominal Operating Pressure E] Exempt 0 Other ] Pressure __ psi Test Temp. - 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code .Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 Ap1 B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -O'ts 45;..ý.r, Date Z/// 200 Owner or Owner's tmsignee, Title .J CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period II ',* %3 to KIl , and state that to the best of my knowledge and belief, the owner has performed
-t,,,
examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
" *Commissions NeJI'l"IIS0 A L .1L2l I. /
orN Signatlure National Board. State. Province, and Endorsements flT],Wt 20 lZ 20 __
_______13 Iat _____________________________________________
17
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 4/03/2(0 13 4300 Winfield Road Sheet: I of 1 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-145 WO: 1461979-01 22710 206th Ave. North, Cordova. IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor Recirculation, Class i
- 5. (a) Applicable Construction Code: USAS B3 1. I Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic EL Pneumatic F1 Nominal Operating Pressure [] Exempt ED Other F] Pressure __ psi Test Temp. __ 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ."W ' -*,x Oo, 651 i A/
,,,O
- Date 9/ 7 20 1L Owner dr Owner'SJDesignee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i4 -r to 6 r 11 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this.Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property amage or a loss of any kind arising from or connected with this inspection.
_ ____Commissions IJat7l A N I IL. ZJII specrors Signature Nadi)onalBoard. State. Province, and Endorsements Date to' e 20**20V3
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 4/03/2013 4300 Winfield Road Sheet: I of 1 Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-146 WO: 1461980-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor Recirculation, Class I
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Snubber Pacific Scientific UTC 2916655 N/A 1-0202-B 12 N/A Replacement No Co.
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic 0 Pneumatic E Nominal Operating Pressure E] Exempt 0 Other 5] Pressure ___ psi Test Temp. 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed - !2g', ,6.I-," A? /" Date 20/LL Owner or Owner's lDesignee. Title.) j CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period hp
,' to K ".v I'S , and state that to the best of my knowledge and beliet; the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
,ýý Z =Z Commissions ,,?, AP \ I. 7z" Y11sped',ri .igflature inal Board. Siate.Province. and Endors.ýments al~iz Date Ig *PI'* 20 t3 Dlate IR'Af'ft 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 3/29/2013 430()0 Winfield Road Sheet: I of 1 Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-147 WO: 1461986-01 22710 2061h Ave. North, Cordova, IL 61242 Repair Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Residual Heat Removal, Class 2
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A 6, Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Snubber Pacific Scientific UTC 2916670 N/A 1-1025-79 N/A Replacement No Co..._.
Taper Pin Anvil UTC 2916110 N/A I- 1025ý-79 N/A Replacement No International, Inc
- 7. Description of Work: Replaced snubber and taper pin.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure E] Exempt El Other F1 Pressure __ . psi Test Temp. - F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code .Section Xt Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed .. , 6wc //&,/ ' Date 4/117 20L.L Owner oe Owner's'gesignee, TitlaJ.1 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois . and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7,k pu,.- XT. to 7.- "-L1-'3 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a los of any kind arising from or connected with this inspection.
Commissions *'lAts -AN i 7:t clors Signature Namioai Board. Slae. Province. and Endor'onielOs Date C- APR 20 kS
FORM NIS-2 OWNERS REPORT OF REP.AIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 3/29/2013 4300 Winfield Road Sheet: I of _1 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-148 WO: 1461991-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No.. Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Control Rod Drive, Class 2
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure [ Exempt 0 Other El Pressure - psi Test Temp._ OF
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ' t "* ,,?', d5; i"- Date -7 270/_
Owner or'Owner'YLDesignee, Ti.* v CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period -1 AwX,-V to 7. rnxt Z3 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate. neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damag or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ Commissions P IZ'131 AN IL ZZI (M..*n*,pech~rs Sinnarure National Bo'ard. State. Province. and Endorsements Date 'F ,APR- 20 1-3
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 3/29/2013 4300 Winfield Road Sheet: I of /
Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-149 WO: 1461990-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Control Rod Drive, Class 2
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A ification of Components Repaired or Replaced, and Replacement Components:
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic 11 Pneumatic El Nominal Operating Pressure LI Exempt [
Other F1 Pressure _ psi Test Temp. __ OF
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code .Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Sine %.7 '- , 29,A ,"t.,,, *i',i /-."Date______________
Signed 20 1 Owner or Owner's Designee, Title -,. .3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z4'*Lz to "*tmot,'3 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
// gComnmissions *VIIJEIJB*AVEE* 4NRMISI
- .* w iN0t % 117Z
- w*"
osSignatrure Board.Slate, Prnvince.
Natiojnal aindEndors~ements Date I-Z I*PR. 20 /g Date 1- AM -20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/14/2013 4300 Winfield Road Sheet: I of I.
Warrenville, 11.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-150 WO: 1439881-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re lacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Valve Dresser Industries S/N BK7060 N/A 1-0203-3D N/A Replacement No Stud Nova UTC 2928088 N/A 1-0203-3D N/A Replacement No Stud Nova UTC 2928089 N/A 1-0203-3D N/A Replacement No Hvdranut Nova UTC 2908998 N/A 1-0203-3D N/A Replacement No
- 7. Description of Work: Replaced valve and bolting.
- 8. Tests Conducted: Hydrostatic U Pneumatic E Nominal Operating Pressure [ Exempt U Other F1 Pressure _ psi Test Temp._ 'F
- 9. Remarks: Performed VT-I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code.Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -0Z,,4-. XU ':,,,/U *_k c'¢. Date_ ____ ____ 2013' Owner or Ownd*'s DesigneeTTitle ,
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois . and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /I MA t13 to Z , mtSt3 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
4*I1/,
f pe ors' sign"Iure Commissions 1J8tri A v I IL LZZ\%
National Board. State. Pnrvince. and Endorsements Date )(6 M;,ý 20 1_
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/14/2013 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station ProgramNo.: 12-151 WO: 1439882-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Valve Dresser Industries S/N BY94636 N/A I-0203-3C N/A Replacement No Stud Nova UTC 2928088 N/A 1-0203-3C N/A Replacement No Stud Nova UTC 2928089 N/A 1-0203-3C N/A Reolacement. No Hydranut Nova.. UTC 2908998, N/A 1-0203-3B N/A Replacement No 2936578,
______ ___ 2906827 -
- 7. Description of Work: Replaced valve and bolting.
- 8. Tests Conducted: Hydrostatic 0l Pneumatic E3 Nominal Operating Pressure 0 Exempt Ql Other El Pressure - psi Test Temp. 'F
- 9. Remarks: Performed VT- I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed *-7. /e1,,"ol",Po
,*d 14 ,/O Date '/'* 20/-S Owner or Owner's Efesignee,TAW V I CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HS1B CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period U3 r-t.3 to Z'-I MV,1 - and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property d of any kind arising from or connected with this inspection.
Commissions 1*RI"/lS.A* LZZ.1t I '--4APectorq Signatlure National Board. State. Province. and Endorements Date 1(6 IV1,' 20 I1
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/14/2013 4300 Winfield Road Sheet: I of _1 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-152 WO: 1470273-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Ouad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class 1
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A tification of Components Repaired or Replaced, and Replacement
- 7. Description of Work: Replaced valve and bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic E1 Nominal Operating Pressure 0 Exempt E]
Other El Pressure __ psi Test Temp. __ 'F
- 9. Remarks: Performed VT-I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -2 '40U r, l/Ojr," 1,4 .rj* DateA, 20 Owner or Owner's 'esignee, Title"-
CERTIFICATE OF INSERVICE INSPECTION i, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois . and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,3MW 13 to Z'.MLV , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
CommissionsN t'RI3tIS g IL7t ctors Signature Natlional Board. State. Pnwince. and Endorsements Date /6 MAY 20 '3
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/15/2013 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-153 WO: 1439883-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No.. Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 2"710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced. and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired. ASME Code Component Mfr. No. Bd. Identification Built Replaced. or Stamped No. Replacement (Yes or No)
Valve Cons Safety Valve S/N BK6264 N/A 1-0203-4C N/A Replacement No Stud Nova UTC 2924793 N/A I-0203-4C N/A Replacement No Hydranutt Nova UTC 2892994 N/A 1-0203-4C N/A Replacement No Hex Nnts Accutech UTC 2909644 N/A 1-0203-4C N/A Replacement No
- 7. Description of Work: Replaced valve and bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure [ Exempt El Other F1 Pressure __ psi Test Temp. 'F
- 9. Remarks: Performed VT-I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 2ý-t0 --12, c5;o1i'-
, Date______________ __ 20 /...
Owner or Owner's Desigfiee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period (3 MAP, %3 to ZS PlAtf 1 , and state that to the best of my knowledge and belief. the owner has pertormed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions \*11-7k1S A ,0 1 L--l I
/ $rp~crors Signature N-aIirnai Board, Stat~e.
Province. and End,,rennents Date I(* r*A'-t 20 1:3 Date I& 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 5/15/2013 4300 Winfield Road Sheet: I of I Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-154 WO: 1439884-01 22710 206th Ave. North, Cordova. IL 61242 Repair Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 227 10 206th Ave. North, Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B3 I. I Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re lacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced. or Code No. Replacement Stamped (Yes or No)
Valve Cons Safety S/N BK7155 N/A 1-0203-4D N/A Replacement No Valve Stud Nova UTC 2924793 N/A 1-0203-4D N/A Replacement No Hydranut Nova UTC 2801055, N/A 1-0203-4D N/A Replacement No 2736367 ____ ___ Replace___
Flex Nuts Accutech UTC 2887769 N/A 1-0203-4D N/A Replacement No
- 7. Description of Work: Replaced valve and bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic F1 Nominal Operating Pressure [ Exempt F1 Other FI Pressure _ psi Test Temp. _ 'F
- 9. Remarks: Performed VT-I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed "4',
oe 4,/ Date -/14' 20/.L Owne~r or wOner's Yesignee. Titeli CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i 3 f"aft to Z4 MR3 J , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate. neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damageor a s of any kind arising from or connected with this inspection.
Commissions I'*N0 lI7S . t ILt-7-11 I ?ýiizrclr~s Si~mnnittI .~inlBoard. .'tle. Prnvince. ar~dEndor.-ments
-,O Date X- IYNO 20 )3 I
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company. LLC Date: 5/15/20!13 4300)Winfield Road Sheet: I of J Warrenville. 11.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-155 WO: 1439885-01 22710 206th Ave. North. Cordova. IL 61242 Repair Organization P.O. No., Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None
?2710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)
Valve Cons Safety Valve S/N BK7165 N/A 1-0203-4G N/A Replacement No Stud Nova UTC 2859490, N/A 1-0203-4G N/A Replacement No 2888859 1 1
_Lydranut Nova UTC 2736367, N/A I-0203-4G N/A Replacement No
-2736368 Hex Nuts Acctttech, Nova UTC 2909644, N/A I -0203-4G N/A Replacement No 1 2735812
- 7. Description of Work: Replaced valve and bolting.
- 8. Tests Conducted: Hydrostatic EL Pneumatic El Nominal Operating Pressure [ Exempt [
Other F1 Pressure __ psi Test Temp. - OF
- 9. Remarks: Performed VT-I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair I Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Siened " , -oac *.,ý ,/4" Date IX",/ 0/
Owner or Owher's DeMgnee, Title D CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i's IS..
I tO MR i's . and state that to the best of my knowledge and belief. the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property daamage or a loss of any kind arising from or connected with this inspection.
___ ___/_ _ Commissions N931-lSA 4 tk N\ t L.ZZI I T- rchins Siinature "' ;jtnmal Board. Staie. Province. and Endorsemenus Date I*. lv*kY ?0 13 Date 1(6 M-012t
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/15/2013 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-156 WO: 1439886-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class 1
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat1 Other Year Repaired, ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)
Valve Cons Safety Valve S/N BK6249 N/A 1-0203-4H N/A Replacement No Stud Nova UTC 2924793 N/A 1-0203-4H N/A Replacement No Hydranut Nova UTC 2736367. N/A 1-0203-4H N/A Replacement No 2736372, 2906810 -0203-g hL__
Hex Nuts Accutech UTC 2887769 N/A 1-0203-4 N/A Replacement No
- 7. Description of Work: Replaced valve and bolting. t1 - "
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure [ Exempt E]
Other E] Pressure _ psi Test Temp._ 'F
- 9. Remarks: Performed VT-I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section X!
Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed "-, ,s-*,[. ., , cf"Q-'
jtV`Date 20 /3 Owner or O~4ner's Delignee. Title CERTIFICATE OF INSERVICE INSPECTION i, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT, f Hartford, Connecticut have inspected the components described in this Owner's Report during the period 13PlAt t3 to ZS ,,lt , and state that to. the best of my knowledge and belief, the owner has performed axaminations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective neasures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or iroperty damage or a loss of any kind arising from or connected with this inspection.
- If Commissions N12131r7gAMI iLUI
/ IiSnsp~trs Signature National Board. State. Province. and Endur,,ements
)ate /4, tPWI 20 U$
)iite /' 20
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/1512013 4300 Winfield Road Sheet: I of 1 Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-157 WO: 1472713-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1968 Addenda: Winter 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No).
Valve Tareet Rock S/N 225 N/A 1-0203-3A N/A Replacement No Stud Nova UTC 2914322 N/A 1-0203-3A N/A Replacement No Hydranut Nova UTC 2908996 N/A 1-0203-3A N/A Replacement No Hex Nut Nova UTC 2927084 N/A 1-0203-3A N/A Replacement Noo
- 7. Description of Work: Replaced valve and bolting.
- 8. Tests Conducted: Hydrostatic E] Pneumatic E- Nominal Operating Pressure [ Exempt fl Other E] Pressure __ psi Test Temp.__ 'F
- 9. Remarks: Performed VT-I on bolting.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code.Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 AVp B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed O 4, 1 P,',.it _ ,- Date -- 20 I Owner or Owner'i-Designee, Titl /-
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois . and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period al *,*t 11 to Z MQ 0" , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___Commissions 02 13l-1S -A \ IL\LZZl Impectors signature National Board. State.Prmvince. and Endorsements Date 1 MMx'l 20 [3 I
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 12/18/2012 4300 Winfield Road Sheet: I of /
Warrenviile, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 12-187 WO: 1583204-05 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Core Spray, Class 2
- 5. (a) Applicable Construction Code: B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'[ Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Pump CHEMPUMP UTC 2686033 N/A 1-1402-57 N/A Replacement No
- 7. Description of Work: Replaced Pump.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure 0 Exempt El Other El Pressure __ psi Test Temp. 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed M R&
P ^tirav i,A rDate I-ell? 20 t Owner or Owner's'Designee, itle U CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period iIloT 1Z to 3" ,.av 1 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ Commissions rip. ;L,Pý iLvL, I "f ctors Signature National Board, State, Prnvince, and Endorsements Date * *=* 20 Date q4,- 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/15/2013 4300 Winfield Road Sheet: I of 1 Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: I2-190 WO: 1539077-01 22710 206th Ave. North. Cordova. IL 61242 Repair Organization P.O. No.. Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Feedwater, Class I
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Corponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Disc/Seat Ring Crane UTC 2884950 N/A SN/A Replacement No
- 7. Description of Work: Prepared new disc/seat ring for installation.
- 8. Tests Conducted: Hydrostatic El Pneumatic E1 Nominal Operating Pressure [ Exempt [
Other E] Pressure __ psi Test Temp. - F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed /*o,1/4"f, CktjI go' , ," Date -5146 20 /3 Owner or Ow'ner's Dest'gnee. Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /FB "3 to I A \%-V , and state that to the best of my knowledge and belief. the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a losf any kind arising from or connected with this inspection.
,/ -- f" Commissions r\)& I'Y-1S AMt 1 IL--.ZI I I",pFctors Signature NationaljBoard. State. Province. and Endorwvments L Date 17 IM."
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 3Y2512013 4300 Winfield Road Sheet: I of 1 Warrenville. II. 60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 12-192 WO: P.O. 488210 RIN 215978 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No.. Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC, 29306 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class 1
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1968 Addenda: Winter 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Target Rock Valve Target Rock 198 N/A UTC 2911154 N/A Repair / No Replacement
- 7. Description of Work: Drilled two thermowells and machined inlet/ outlet face and tongue.
- 8. Tests Conducted: Hydrostatic El Pneumatic 0l Nominal Operating Pressure [ Exempt [
Other E] Pressure _ psi Test Temp. - F
- 9. Remarks: An internal VT-3 examination performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed " .:,,t/i*,*ft
.J I 1(4*1
ýJ Date 4/1___ 20
? .
Owner or Owder's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 1 l- 1Z to 74 N 1'm , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Z /* Commissions NR 13'1-1S Avi, I IL-2-t11 National Board. State. Pnrvince. and Endorsements I y Inspectors Signature 70 1*
0 (3 Dat P AnPdRs S2ntr
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 3/25/2013 4300 Winfield Road Sheet: I of _1 Warrenville, II. 60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 12-194 WO: P.O. 424879 RIN 215980 22710 206th Ave. North. Cordova. IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC, 29306 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class 1
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1995 Addenda: 1996 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Electromatic Relief Dresser- BY94636 N/A UTC 2785137 N/A Repair / No Valve _Replacement
- 7. Description of Work: Removed cracked cage welds, removed/re-installed turnbuckle boss and pilot sensing tube, installed helicoils and machined flange face.
- 8. Tests Conducted: Hydrostatic El Pneumatic [] Nominal Operating Pressure [ Exempt [
Other FI Pressure __ psi Test Temp. - 'F
- 9. Remarks: An internal VT-3 examination performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed~~~Owner
"* -- or Owner's D~ignee. Title"- //* Date 20/2 1__
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ' b¢c. i* to Z'1 ,O. . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _Commissions ,131-79 A 1,3) IL7t'1\
/ s ignature Natinal Board. State. Province. and Endorsements Date 1"7 APi-- 20 \._ _
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 3125/2013 4300 Winfield Road Sheet: I of _1 Warrenville, II. 60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 12-195 WO: P.O. 499002 RIN 215860 22710 206th Ave. North, Cordova. IL 61242 Rcpair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC, 29306 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class i
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1968 Addenda: Winter 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re lacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Target Rock Valve Target Rock 172 N/._._EA UTC 2928909 N/A Repair / No Replacement
- 7. Description of Work: Drilled two thermowells.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt [
Other El Pressure ___ psi Test Temp. - F
- 9. Remarks: An internal VT-3 examination performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -* !y of.O0wner's i6?ý,g."cc.,i t*4:,--.J Date 201/
Owner J*esignee. Title - "
CERTIFICATE OF INSERVICE INSPECTION I.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 1`bst Iz to 4 M I's - , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ Commissions PIv3175 ANI it. ,i V loped ors Signature Natjional Board. State. Province. and Endorsements Date 1-7A*rl- 20 /3 Date U7AYfl. 20 /1
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company. LLC Date: 3/25/2013 4300 Winfield Road Sheet: I of I1 Warrenville. I1.60555 Unit: 0 2.Plant: Quad Cities Generating Station Program No.: 13-001 Rev. I WO: P.O. 496783 RIN 215981 22710 206th Ave. North, Cordova. IL 61242 Repair Organization P.O. No., Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC, 29306 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: ASME B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 7. Description of Work: Removed cracked cage welds and replacecd guide and main disc.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure EJ Exempt [
Other F1 Pressure _ psi Test Temp. __ 'F
- 9. Remarks: An internal VT-3 examination performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 77 4 *3 , ' ,
Owner or OW'ner's Defgnee. Title
, Date 4/ 2 206 J
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period z.1 3,0 ri to r',,. t3 . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ ___ _ _ _ Commissions rCrms AN, IL-ZM ctors Signature National Board. Slate. Province, and Endorsements Ye Da np7 20 I:
Dat 1- -AM___________________________________
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 5/31/2013 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: 1 2.Plant: Quad Cities Generating Station ProgramNo.: 13-004 WO: 1448076-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Residual Heat Removal, Class 2
- 5. (a) Applicable Construction Code: ASME Sec. VIII Edition: 1968 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)
Floating Head General Electric UTC 2937493 N/A 1-1003-A N/A Re lacement No Expansion Joint Hvspan Precision UTC 2935774 N/A 1-1003-A N/A Reolacement No Cao Nut GE / Nova UTC 2931323, N/A 1-1003-A N/A Replacement No 2931577 Hex Nut Nova UTC 2931325, N/A 1-1003-A N/A Replacement No 2931326 Stud Nova UTC 2931329, N/A 1-1003-A N/A Replacement No 2931330, 2931578, 2927945 Threaded Rod Nova UTC 2930568 N/A 1-1003-A N/A Replacement No Hex Nut Nova UTC 2931322 N/A 1-1003-A N/A Replacement NI..o
- 7. Description of Work: Installed floating head, expansion joint, and bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure 0 Exempt C Other [] Pressure _ psi Test Temp. - F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed e7Aj I
- va,4 Owner or Ownefs Desighde, Title J A
Date 4/7 20/LL CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period I1 11 -5to 7-1 M'1.3 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions M 17
- ILZZi National Board, State, Province, and Endorsements Date t2 ',-t',. 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As ReqtUired by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 3/25/2013 4300 Winfield Road Sheet: I of I1 Warrenville, II. 60555 Unit: 0 2.Plant, Quad Cities Generating Station Program No.: 13-005 WO: P.O. 488211 RIN 215853 22710 206th Ave. North. Cordova. IL 61242 Repair Organization P.O. No., Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: NWS Technol6gies Authorization No.: None 13 1 Venture Blvd., Spartanburg, SC, 29306 Expiration Date: N/A
- 4. Identitication of System: Main Steam, Class 1
- 5. (a) Applicable Construction Code: ASME Section III Edition: 1968 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 7. Description of Work: Replaced disc holder and guide.
- 8. Tests Conducted: Hydrostatic [I Pneumatic E5 Nominal Operating Pressure El Exempt 0 Other 51 Pressure __ psi Test Temp. __ 'F
- 9. Remarks: An internal VT-3 examination performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear I 0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed _______________________Date )'/6 20 ZL Owner or Owtier's De~gnee, TitleJ* 0 CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period V I? to Z'rrhvl , and state that to the best of my knowledge and belief. the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ __ _Commissions -Nl I7MS A N I IL Z1it Y17 fnmp. "nature 20 Natiomal Board. Sta*e. Province, and Endor.emenrs Daite R7 APM? 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/17/2013 4300 Winfield Road Sheet: I of /
Warrenville. II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-006 WO: 880894-30 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No.. etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: NWS Technologies Authorization No.: None 131 Venture Blvd., Spartanburg, SC, 29306 Expiration Date: N/A
- 4. Identification of System: High Pressure Cooling Injection, Class 2
- 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Coiponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
N/A N/A N/A N/A 1-2305-10" N/A Repair No
___________ _______Replacement
- 7. Description of Work: Installed pipe following HPCI overhaul.
- 8. Tests Conducted: Hydrostatic 0 Pneumatic El Nominal Operating Pressure 0 Exempt El Other L] Pressure _ psi Test Temp._ 'F
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code.Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed *7f"-&C ? _- , ,',' * /144 4([, Date .5/Z1 20 13 Owner or Oner's DVsignee. Title-CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period IZrFR rs to 5 fPL-I' , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a I o kind arising from or connected with this inspection.
ZL-y Commissions NJR 1917S -At03 IL'7-2-*,
VInsp"ec inature National Board, State. Province. and Endosernemnts Date ZZ - AI 20o 1'
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 6/12/2013 4300 Winfield Road Sheet: I of I Warrenville, Il. 60555 Unit: 1 2.Plant: Quad Cities Generating Station Program No.: 13-014 WO: 1616873-04 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Main Steam, Class I
- 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1955 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Plug / Stem Crane-Aloyco UTC 2936993 N/A Spare N/A Replacement No Assembly I I I I_ 1
- 7. Description of Work: Machined in accordance with EC 391678.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure E] Exempt Z Other [] Pressure _ psi Test Temp. °F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed '--, P,*t'Oan Owner or Ow6er's Defgnee, Title 61t Date ___ __ 20_3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period IZP '3 to I ' om4 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___Commissions MR IXI"75 -AN I IL7ZLII y(Joectors signature National Board, State, Province. and Endorsements Date fl ,-S 20 1-3
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 5/31/2013 4300 Winfield Road Sheet: I of 1 Warrenville, II. 60555 Unit: 1 2.Plant: Quad Cities Generating Station Program No.: 13-017 WO: 1623414-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Control Rod Drive, Class 1
- 5. (a) Applicable Construction Code: ASME Section mI Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
CaM Screws Nova UTC 2901405 N/A 1-0300-42-11 N/A Replacement No
- 7. Description of Work: Replaced bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure 0 Exempt El Other E] Pressure - psi Test Temp._ 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed "2 P:o4/" 7 *l
- r Date "/,?/20]5 Owner or CAvner's Ddignee, Title- '-
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 17 M* 3 - to Zo M~ rI-& , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss f any kind arising from or connected with this inspection.
_ _ UCommissions
_ _ iW82I15 AN I IL-7-Vl rs Signature National Board, State, Province, and Endorsements iFlare 21 IcN*"I 20
- Daote 31I M4a 20 11
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 4/03/2013 4300 Winfield Road Sheet: I of _1 Warrenville. I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-019 WO: 1462003-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No., Job No.. ctc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 106th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Residual Heat Removal, Class I
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or I_ I I No)
Snubber Lisega USA Inc. UTC 2937618 N/A 1-1025-122 N/A Replacement No
- 7. Description of Work: Replaced snubber.
- 8. Tests Conducted: Hydrostatic El Pneumatic 0l Nominal Operating Pressure El Exempt Z Other F1 Pressure __ psi Test Temp. - 'F
- 9. Remarks: Performed VT-3 on replaced snubber.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed e; , *6;g, 1j, , rf Date 7 20 ..
Owner or OPwner's Defgnee, Title ) J .
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period rI P- Ir to i rmx I-S , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____ ____ ____ ____ Commissions Nk 1311S k N I IL Z11 pectoir, signature National Board. State. Province. and Endorsý!ments nr*/I" AP* *t* I*
Date/? AR- M' 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 5/28/20 13 4300 Winfield Road Sheet: I of .1 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-022 WO: 1624044-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Feedwater, Class I
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N-416-3
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Assembly Crane UTC 2908450 N/A 1-0220-58B N/A Replacement No
- 7. Description of Work: Replaced the disc/seat ring assembly.
- 8. Tests Conducted: Hydrostatic E1 Pneumatic D Nominal Operating Pressure fl Exempt Z Other fE Pressure _ psi Test Temp. - 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed , ,D 61 at,* Date "/ 20 Owner or OAvner's De-4tnee, Title .- ,
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Za v's, I3to Z's m,,VbI'% , and state that to the best of my knowledge and belief. the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code.Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_Commissions 't l31"15' P NJ I 1LZZ'k National Board. State. Prnince. and Endorsements Date 30 MAN 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 5/28/2013 4300 Winfield Road Sheet: I of I_
Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-024 WO: 1623835-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor Recirculation, Class I
- 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Com ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Flat Bar Energy & Process UTC 2914374 N/A 0200-W- 104A/B N/A Repair No Nut Various UTC 2620183 N/A 0200-W- I04A/B N/A Reair No
- 7. Description of Work: Replaced support lugs and bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic F1 Nominal Operating Pressure E Exempt [
Other 0 Pressure _ psi Test Temp. - 'F
- 9. Remarks: Performed VT-3.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed "Q1,t P,, t e, W44,a,/, Date 20 *L Owner of Owner4 Designe. Title I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 2'-i tn'h I'I to Z-71 I- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____ ___ ____ ___ ___ Commissions , ri"l115 A W I ILZ.I
-Inspectors Signature National Board. State. Pn)vince. and Endorsements I-ane :ý mhi:. 20 13 flnr ~O *:'n 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 5/28/2013 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-025 WO: 1624129-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. identification of System: Reactor Recirculation, Class 1
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Co pornents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Hanger N/A N/A N/A 0200-W-I05A/B N/A Re air No
- 7. Description of Work: Tightened loose bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic E Nominal Operating Pressure E1 Exempt [
Other [] Pressure _ psi Test Temp. - 'F
- 9. Remarks: Performed VT-3.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed % V'.F 3/4t/A6*,., Date _ _ __ __ __20 Owner or Owner's Wsignee. Titws CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period "&M 13 to . rMV- 13 . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ ____ ____ Commissions )"X 13'-S 31-7-21' A t1 I nspectrs Signature National Board. State. Province. and Endorsements
(ý
,ae3 20 )3 Date So 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 6/3/2013 4300 Winfield Road Sheet: I of I Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-026 WO: 1624130-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor Recirculation, Class 1
- 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Flat Bar Energy & Process UTC 2914374 N/A 0200-W-124A/B N/A Repair No
- 7. Description of Work: Tightened loose bolting and replaced lugs.
- 8. Tests Conducted: Hydrostatic E] Pneumatic [] Nominal Operating Pressure E] Exempt 0 Other Q Pressure __ psi Test Temp. 'F
- 9. Remarks: Performed VT-3.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 1 Po. r ,n Z*k dLt,.1 Date __ __ __ __ 201_
Owner or Owner's Designee, TiMt
- IQ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z4 MIhr. 3 - to ."IMMrQ- 13 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__// Commissions I02 11"7S A v,)I IL--Lvi nature National Board, Swe, Province, and Endorsements Date 4 JVM 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 6/3/2013 4300 Winfield Road Sheet: 1 of '1 Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-027 WO: 1624353-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor Recirculation, Class 1
- 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Co ponents Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Hanger N/A N/A N/A 0204B-M-101 N/A Repair No
- 7. Description of Work: Tightened loose bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic E] Nominal Operating Pressure Q Exempt [
Other Q1 Pressure - psi Test Temp. _ OF
- 9. Remarks: Performed VT-3.
CERTIFICATE OF COMPLIANCE We certify thatthe statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed . ;0"Sm ft "'w a 6Jo4 f Date _ _____ 201S Owner or Of~ner's DMignee, Title-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period M. - 13 to LS rA- 'S , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ _ _Commissions OR I!'& S - NJ I 1LZ7.A\
11spectia Signature National Board, state, Province, and Endorsements Date 4 3IW 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI
- 1. Owner: Exelon Generation Company, LLC Date: 5/28/2013 4300 Winfield Road Sheet: I of 1 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-028 WO: 1624817-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor Recirculation, Class 1
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
N/A i 0200-W-107A/B N/A e No)
Hanger N/A N/A
- 7. Description of Work: Tiphtened loose bolting.
- 8. Tests Conducted: Hydrostatic L Pneumatic [ Nominal Operating Pressure El Exempt Z Other [] Pressure ___ psi Test Temp. 'F
- 9. Remarks: Performed VT-3.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ' Z , , *" ,*j'i Date 20LL*
Owner or Owner's Designee. Title" CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z3 MrIS to ,r'sa' . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section Xl.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___Commissions X- l317 A t*I. ILZZ11 Sure National Btiard. State. Province. and Endorsements Date .-* m*a 2)0 1-.
Date 350 M:J1 2 t
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/28/2013 4300 Winfield Road Sheet: I of _1 Warrenville, II. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-029 WO: 1624818-01 22710 206th Ave. North. Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North. Cordova. IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor Recirculation, Class I
- 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Com ponents Repaired or Replaced. and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced. or Code No. Replacement Stamped (Yes or No)
_Hanger N/A N/A N/A 0200-W- I29A/B N/A Repair No
- 7. Description of Work: Tightened loose bolting.
- 8. Tests Conducted: Hydrostatic F1 Pneumatic El Nominal Operating Pressure [ Exempt [
Other E1 Pressure __ psi Test Temp. 'F
- 9. Remarks: Performed VT-3.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear IOCFR50 App B.. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A I0 14o" 6114 , 514_ 20 Signed ,"
Owner or Owrler's Dt*lgnee, Title-- 3VDate CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ' Mk', to Z'3 MIL13 , and state that to the best of my knowledge and beliet: the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _Commissions .)3f"-IS 4AK)I ILZII W aors Signature National Board. State. Province. and Endorsements Date
- P'* 20 13 Date 3a r'vý 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/28/2013 4300 Winfield Road Sheet: I of I1 Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-030 WO: 1624819-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor Recirculation, Class 1
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Hanger N/A N/A N/A 0200-W- 128A/B N/A Repair No
- 7. Description of Work: Tightened loose bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure [ Exempt [
Other F] Pressure __ psi Test Temp. - 'F
- 9. Remarks: Performed VT-3.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A- Exelon Nuclear 10CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -;a' 0 Pt /o,, tbI //4**fm Date , 20 "
Owner or Owner's D1signee, Title-.J J f CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period SMAR*t-- to 21 ..,t 13 . and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate. neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ Commissions fr"s a
[74g j3 t (L-L Za-l Inpectors Signature Naikinal Board. State. Psivince. and Endorsements Date .-* /"*'t 20 13 Date~ 30 M0 ~ 20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/28/2013 4300 Winfield Road Sheet: I of I Warrenville, 11.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-031 WO: 1625361-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Residual Heat Removal, Class 1
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No) nger N/A N/A N/A 1012B-W- 104 N/A Reair No.
- 7. Description of Work: Tightened loose bolting.
- 8. Tests Conducted: Hydrostatic 0 Pneumatic El Nominal Operating Pressure ] Exempt 0 Other MJ Pressure _ psi Test Temp. - F
- 9. Remarks: Performed VT-3.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A- Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Owneorg, ", n tei tat/ Date 20S*
Owiner or Owner's Resignee, TitlI ,J CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z3 Mtp vs to Z3 InLe.l's , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property amage or a loss of any kind arising from or connected with this inspection.
Commissions Ne IT"1S - V 0'T k 1V J2A-.
h'pectoýrs Signature National Board. State. Ptovince. and Endorsements Date .36 I"'*"N 20 I'S Date 3'~ tvr~9 20 I'~
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 5/28/2013 4300 Winfield Road Sheet: I of I Warrenville, Ii. 60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-032 WO: 1625360-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Residual Heat Removal, Class i
- 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N/A
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Hanger N/A N/A N/A 1012A-W-104 N/A Repair No
- 7. Description of Work: Tightened loose bolting.
- 8. Tests Conducted: Hydrostatic El Pneumatic F1 Nominal Operating Pressure E Exempt [
Other F1 Pressure __ psi Test Temp. - OF
- 9. Remarks: Performed VT-3.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code . Section Xl Type of Code Symbol Stamp N/A - Exelon Nuclear I0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ,,,;* *?*4,r E i A.4 ciaqdDate 5 1/*O 20L/
Owner or Owner' rDesignee, T.ie J CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period "Z3 t's to -&t -,n's , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ ___Commissions
_ NR -I-1S A * ' ILI-'Z.\
f 'h,,.'tors Signature National Board. State. Province. and Endorsements Date 30.MPY 20 12, Date30 f'~.f20 13
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC Date: 4/30/2013 4300 Winfield Road Sheet: I of I Warrenville, I1.60555 Unit: I 2.Plant: Quad Cities Generating Station Program No.: 13-033 WO: 1626729-01 22710 206th Ave. North, Cordova, IL 61242 Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp: None
- 3. Work Performed by: Quad Cities Generating Station Authorization No.: None 22710 206th Ave. North, Cordova, IL 61242 Expiration Date: N/A
- 4. Identification of System: Reactor, Class 2
- 5. (a) Applicable Construction Code: Section III Edition: 1965 Addenda: Summer 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: Edition: 1995 Addenda: 1996 Code Case: N-416-3
- 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)
Pipe N/A N/A N/A 1-0215-2"-B N/A Repair 'No
- 7. Description of Work: Repaired pipe leak.
- 8. Tests Conducted: Hydrostatic El Pneumatic [j Nominal Operating Pressure [D Exempt El Other E] Pressure _ psi Test Temp. - 'F
- 9. Remarks: None.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code,Section XI Type of Code Symbol Stamp N/A - Exelon Nuclear 10CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 1P rA Date 6LS 203 Owner or O%%Cer's DMignee, Title .J 4 "
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford. Connecticut have inspected the components described in this Owner's Report during the period Z1 1w INS to Z" MAM V& , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code,Section XI.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss*f any kind arising from or connected with this inspection.
Commissions t09 '3'S* -A 0 k IL zTX1 rIns Signatur National Board, State, Province, and Endorsements Date 4, \-- 20 3ý