PLA-5616, Annual Personnel Exposure Report PLA-5616

From kanterella
Jump to navigation Jump to search
Annual Personnel Exposure Report PLA-5616
ML031280126
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 04/28/2003
From: Shriver B
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PLA-5616, RG-1.016
Download: ML031280126 (3)


Text

Bryce L. Shriver PPL Susquehanna, LLC  % *as 4-PP' Senior Vice President and 769 Salem Boulevard

  • Chief Nuclear Officer Berwick, PA 18603
  • Tel 570.542 3120 Fax 570 542.1504 blshriveripplweb corn APR 2 8 2003 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Station OP1-17 Washington, DC 20555 SUSQUEHANNA STEAM ELECTRIC STATION ANNUAL PERSONNEL EXPOSURE REPORT Docket Nos. 50-387 PLA-5616 and 50-388 In accordance with the Susquehanna SES Unit 1 and 2 Technical Specifications, Section 5.6.1, the attached annual personnel exposure report is provided for calendar year 2002 for SSES Units 1 and 2. The report includes only those individuals whose cumulative dose for calendar year 2002 was greater than 100 mrem.

Also, in accordance with Regulation Guide 1.16, Special Maintenance is described as the performance of all plant modifications or changeouts of any plant equipment, piping, etc.

that were not a part of the original plant.

Please contact Mr. Duane L. Filchner at (610) 774-7819 if you have any questions concerning this submittal.

Sincerely, B. L. Shriver Attachment copy: NRC Region I Mr. R. V. Guzman, NRC Project Manager Mr. S. Hansell, NRC Sr. Resident Inspector Mr. R. Janati, DEP/BRP

Attachment 1 to PLA-5616 Annual Personnel Exposure Report for Calendar Year 2002

kNNUAL REG. GUIDE 1.16 NUMBER OF PERSONNEL AND PERSON-REM BY WORK CODE AND JOB 12002 04/07/2003 Page 1 of 1 Station Utilitv Contractor Total Work Code Job Function Code Personnel Person-Rem Personnel Person-Rem Personnel Person-Rem Personnel Person-Rem Reactor Operations And Maintenance 5 0.963 1 0.250 6 1.213 Surv Operating 66 14.639 66 14.639 Health Physics 23 9.696 11 3.289 34 12.985 Supervisory 5 0.993 4 1.049 9 2.042 Engineering

  • --- Total *... 99 26.291 16 4.588 115 30.879 Routine Maintenance Maintenance 176 55.488 163 43.925 339 99.413 Operating 37 9.252 37 9.252 Health Physics 30 11.253 32 14.342 62 25.595 Supervisory 14 2.581 15 5.829 29 8.410 Engineering 2 0.310 40 12.718 42 13.028
  • --* Total ....

259 78. 884 250 76.814 509 155.698 In Service Inspection Maintenance 11 3.608 8 1.289 19 4.897 Operating 1 0.341 1 0.341 Health Physics Supervisory Engineering 6 1.458 6 1.458

^^^^ Total .... 12 3.949 14 2.747 26 6.696 Special Maintenance Maintenance 4 0.867 23 5.344 27 6.211 Operating Health Physics Supervisory Engineering 1 0.218 1 0.218

^^^^ Total ....

4 0.867 24 5.562 28 6.429 Waste Processing Maintenance 4 1.518 4 0.632 8 2.150 Operating 1 1.050 1 1.050 Health Physics 4 1.711 1 0.228 5 1.939 Supervisory Engineering

^^^- Total .... 8 3.229 6 1.910 14 5.139 -

Refueling Maintenance 2 0.361 2 0.361 Operating 5 0.641 5 0.641 Health Physics Supervisory 1 0.153 1 0.153 Engineering

  • --- Total ....

8 1.155 8 1.155 TOTAL Maintenance 202 62.805 199 51.440 401 114.245 Operating 109 24.873 1 1.050 110 25. 923 Health Physics 57 22.660 44 17.859 101 40.519 Supervisory 20 3.727 19 6.878 39 10.605 Engineering 2 0.310 47 14.394 49 14.704

        • Grand Total **** 390 114.375 310 91.621 700 205.996
      • ... All non.'Contractor' personnel are designated 'Station'. 'Utility' category is not used.