PLA-7959, Owner'S Activity Report PLA-7959

From kanterella
Jump to navigation Jump to search
Owner'S Activity Report PLA-7959
ML21196A533
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 07/15/2021
From: Cimorelli K
Susquehanna, Talen Energy
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
SSES U220RIO PLA-7959
Download: ML21196A533 (4)


Text

Kevin Cimorelli Susquehanna Nuclear, LLC Site Vice President 769 Salem Boulevard Berwick, PA 18603 TALEN~

ENERGY Tel. 570.542.3795 Fax 570.542.1504 Kevin.Cimorelli@TalenEnergy.com July 15, 2021 U.S. Nuclear Regulatory Commission 10 CFR 50.55a Attn: Document Control Desk Washington, DC 20555-0001 SUSQUEHANNA STEAM ELECTRIC STATION UNIT 2 20TH REFUELING OUTAGE OWNER'S ACTIVITY REPORT PLA-7959 Docket No. 50-388 In accordance with the requirements of American Society of Mechanical Engineers (ASME) Code Case N-532-5, enclosed is the Owner's Activity Report (Form OAR-1) for the Susquehanna Steam Electric Station Unit (SSES) Unit 2 20th refueling outage (U220RIO). This report is for the second refueling outage of the second inspection period of the fourth inspection interval.

There are no new or revised regulatory commitments associated with this submittal.

Enclosure:

Owner's Activity Repoti for SSES U220RIO Copy: NRC Region I Ms. A. Klett, NRC Project Manager Mr. C. Highley, NRC Senior Resident Inspector Mr. M. Shields, PA DEP/BRP

Enclosure to PLA-7959 Owner's Activity Report for SSES U220RIO

FORM OAR"1 OWNER'S ACTIVITY REPORT ReportNumber~OuA~R~-1 -2~0~9 2 ________________________________________

Plant Susquehanna Steam Electric Station, 769 Salem Blvd .. Berwick, PA 18603 Unit No.,.,_2_--:::---::--:-:-:--- Commercial service date Februarv 12. 1985 Refueling outage no. "'2,_0_ _ _ _ _ __

Qf applicable)

Current inspection lnterval 24 twhc..-------------...,...,--,-:--,---,-,--::-:---------------

<1st, 2nd, 3td, 4th, olher)

Current Inspection period "'2'-"'nd,___ _ _ _ _ _ _ _ _ _ _ _ _- - : : : - : - : : - : - - : : - c : - - - - - - - - - - - - - - - - - -

<1st, 2nd, 3td)

Edition and Addenda of Section XI applicable to the Inspection plans 2007 Edition through 2008 Addenda Date and revision of inspection plans'"'R""ev.!.!l,si-"Jonl.L4:::!L.<2"-/1.!..:4"-'/2,_,0'-'1-"'9_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the Inspection plans '-"N"-/A,_______

Code Cases used for inspection and evaluation: ""'N'"'-5"""1...,3'""'-3"'-'-N,_-"'530<!2~-"'5wN-':--_,6.:'-13"--_,2'-::-_ _-::-:-,.,------,-,---:---:-:--:-------

Qr appRcable,lnctud!ng cases mod!Red by Case N*532 and later revisions)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of ,Uc=-22,0"'-R"'IO"--------

(refueling outage numbei) conform to the requirements of Section XI.

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by OneCIS Insurance Co. of Lynn. MAhave Inspected the IIams described In this Owner'sActlvlly Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report In accordance with the requirements of Section XI.

By signing this certificate nellher lhe Inspector nor his employer makes any warranty, expressed or Implied, concerning the repair/replacement activities and evaluation described In this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected wllh this Inspection.

~~

--I<M'""""-"'l....L.M-'-"-._I,. .M4p,I-'~L(s'1""1~'t-;l:-lu""ro""'--5P=F'----- Commission __.A/..'-'f<d($!,.)-_,,_l,_/tzM+LI(N~ ": I o-n- :-, t-~'f.e e:f'""':-;:.bo-ra-nd.,.,E=-n-:-do-rse_rn_en-::-t)_ _ _ _ _ _ __

TABLE1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Number Item Description Evaluation Description None TABLE2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Description of Work Date Completed Repair/Replacement Plan Number Class 3 HRC207-1 ESW Piping Replace ESW piping Through Wall Leak HRC207-1 4/6/2021 20-254-2277478-015 Class 3 2" ESW Throttle Valve Replace ESW throttle 211111 Through Wall Leak valve 7/23/2020 20-254-2356331-0-020 Class 3 2" ESW SPHRC222-2 Repair weld downstream FE21158A Flange Through ofESWflange 8/26/2020 20-254-2357091-0-021 Wall Weld Leak