ML22271A794

From kanterella
Jump to navigation Jump to search

E-61283 Enclosure 4, 013a Appendix 2.5-1, Document No. DOS-19-021165-015-NPV, Version 1.0, Safety Analysis Report (Public)
ML22271A794
Person / Time
Site: Orano USA
Issue date: 08/03/2022
From:
Orano USA
To:
Division of Fuel Management
Garcia-Santos N
Shared Package
ML22271A128 List: ... further results
References
A33010, EPID L-2022-DOT-0007
Download: ML22271A794 (2)


Text

Non-proprietary version Formulaire : PM04-4-MO-6E rév. 03 Orano NPS SAFETY ANALYSIS REPORT Unrestricted Orano APPENDIX 2.5-1 FCC3 / FCC4 Prepared by Verified by Identification :

DOS-19-021165-015-NPV Version :

1.0 Page 1 / 2 TABLE OF CONTENTS REFERENCE VERSION TITLE FFDC 00817 E0 4.0 Safety / criticality study of FCC3 and FCC4 containers -

15x15 and 17x17 assemblies - 17x17 XL, 17x17 EPR, 16x16 and 18x18 assemblies 0

orano

Formulaire : PM04-4-MO-6E rev. 03 Unrestricted Orano Orano NPS Identification :

DOS-19-021165-015-NPV Vers.

1.0 Page 2 of 2 Non-proprietary version Status of revision Version Date Purpose and record of changes Prepared by / Verified by Old reference: DOS-13-00081778-501 00 04/2012 First issue New reference: DOS-19-021165-015 1.0 See 1st page Title modification: TM, that is to say trademark in the USA, title without interest anymore Editorial corrections §1, §5.2.2 and §5.3.2 Editorial correction and additional information §1