MONTHYEARML23289A2232023-10-16016 October 2023 Allegations Received from All Sources External to the NRC - Sept 2023 ML23289A2302023-10-16016 October 2023 Discrimination Allegations Received Sept - 2023 ML23289A2272023-10-16016 October 2023 Allegations Substantiated - September 2023 ML23289A2292023-10-16016 October 2023 Allegations Substantiated with Regulatory Response - Sept 2023 ML23289A2212023-07-28028 July 2023 Allegations Open - Sept 2023 ML22348A0872023-07-25025 July 2023 Enclosure - VEGP Unit 4 - 103g - Final Memorandum Table ML23184A0472023-07-0303 July 2023 Dashboard Report 7-3-2023 ML23121A0392023-05-0101 May 2023 Dashboard Report 5-1-2023 ML23093A0862023-04-0303 April 2023 Dashboard Report 4-3-2023 ML22214B4902023-02-0808 February 2023 Enclosure 1 - Operational Program Inspection Status Table ML22214B4932023-02-0808 February 2023 Enclosure 2 - Licensing Actions Status Table ML23038A0082023-02-0707 February 2023 Construction Reactor Oversight Process Resources Report February 7, 2023 ML23033A0232023-02-0202 February 2023 Dashboard Report 2-2-2023 ML22278A0382022-10-0505 October 2022 Dashboard Report 10-5-2022 ML22230C5162022-08-18018 August 2022 Dashboard Report 8-18-2022 ML22208A0242022-08-0101 August 2022 103g - Final Memorandum - Enclosure ML22206A1682022-07-25025 July 2022 Dashboard Report 7-25-2022 ML22206A1712022-07-25025 July 2022 Dashboard Report 7-25-2022 ML22201A0442022-07-20020 July 2022 Voices Dashboard Report for Vogtle Unit 3 as of July 20, 2022 ML22186A0332022-07-0505 July 2022 Dashboard Report 7-5-2022 ML22186A0342022-07-0505 July 2022 Dashboard Report 7-5-2022 ML22173A0122022-06-22022 June 2022 Dashboard Report 6-22-2022 ML22144A0492022-05-24024 May 2022 Dashboard Report 5-24-2022 ML22144A0502022-05-24024 May 2022 Dashboard Report 5-24-2022 ND-22-0242, Request for Alternative: Alternative Requirements for Main Turbine System Valve Testing (VEGP 3&4-IST-ALT-02)2022-04-0808 April 2022 Request for Alternative: Alternative Requirements for Main Turbine System Valve Testing (VEGP 3&4-IST-ALT-02) ML22091A3162022-04-0101 April 2022 NRC Initial Test Program and Operational Programs Inspection Reports 05200025/2022002, 05200026/2022002 ML22087A0962022-03-28028 March 2022 Dashboard Report 3-28-2022 ML21277A0762021-10-0404 October 2021 Vog 4 Dashboard 10-4-2021 ML21215A0062021-08-0303 August 2021 Dashboard Report 8-2-2021 ML21215A0072021-08-0303 August 2021 Dashboard Report 8-2-2021 ML21160A0382021-06-0909 June 2021 Construction Reactor Oversight Process Resources Report June 2021 ML21132A0482021-05-12012 May 2021 Construction Reactor Oversight Process Resources Report May 2021 ML21090A2092021-03-31031 March 2021 Construction Reactor Oversight Process Resources Report March 2021 ML21008A0042021-01-0404 January 2021 Dashboard Report 1-4-2021 ML20343A0742020-12-0202 December 2020 Dashboard Report 12-2-2020 ML20281A3872020-10-0101 October 2020 Dashboard Report 10-1-2020 ML20281A4002020-10-0101 October 2020 Dashboard Report 10-1-2020 ML20183A0902020-09-24024 September 2020 Initial Commission Memo Regarding Status of ITAAC Closure, Inspection, and Licensing Activities for Vogtle Electric Generating Plant, Unit 3 ML20191A3982020-08-14014 August 2020 Table 2 - Vogtle, Units 3 and 4, Resident Inspector Inspection Samples and Hours ND-20-0907, Revision to Proposed Alternative Requirements for Preservice Inspection Acceptance of Volumetric Examinations, in Accordance with 10 CFR 50.551(z)(1),(VEGP 3&4-PSI/ISI-ALT-14R1)2020-07-28028 July 2020 Revision to Proposed Alternative Requirements for Preservice Inspection Acceptance of Volumetric Examinations, in Accordance with 10 CFR 50.551(z)(1),(VEGP 3&4-PSI/ISI-ALT-14R1) ML20121A2902020-04-30030 April 2020 Construction Reactor Oversight Process Resources 1st Quarter CY2020 ML20038A3072020-02-0707 February 2020 Construction Reactor Oversight Process Resources. Quarterly Update. 1st Quarter 2020 ML20035C5542020-02-0404 February 2020 Attachment 1 - Targeted ITAAC Listing for Vogtle Electric Generating Plant Units 3 and 4 ML20035C5612020-02-0404 February 2020 Attachment 2 - Targeted ITAAC Family Listing for Vogtle Electric Generating Plant Units 3 and 4 ML20035C5702020-02-0404 February 2020 Attachment 3 - Targeted ITAAC Changes for Vogtle Electric Generating Plant Units 3 and 4 ML20007D9042020-01-0808 January 2020 Table of Proposed ROP Baseline Samples for Vogtle Site ML16056A1392016-03-11011 March 2016 Correction to the U.S. Nuclear Regulatory Commission Analysis of Licensees' Decommissioning Funding Status Reports ML15106A3612015-04-17017 April 2015 April 22, 2015, Meeting with Southern Nuclear Company, Example Vogtle 1 and 2, Change Justification Matrix ML14307B7072014-12-10010 December 2014 Supplemental Information Related to Development of Seismic Risk Evaluations for Information Request Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) Regarding Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-T ML14078A6202014-04-0101 April 2014 Enclosure 2 - SAMG Entry Flowcharts 2023-07-03
[Table view] Category:Letter type:ND
MONTHYEARND-24-0103, (Vegp), Unit 4 - Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests2024-04-26026 April 2024 (Vegp), Unit 4 - Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests ND-24-0114, Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2024-04-0101 April 2024 Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-24-0046, (Vegp), Unit 3, Condition Prohibited by Technical Specification Limiting Condition of Operation 3.1.6 Control Bank Overlap Limits Exceeded Due to Inadequate Procedure Guidance2024-03-18018 March 2024 (Vegp), Unit 3, Condition Prohibited by Technical Specification Limiting Condition of Operation 3.1.6 Control Bank Overlap Limits Exceeded Due to Inadequate Procedure Guidance ND-24-0059, (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2024-03-0404 March 2024 (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0693, (Vegp), Unit 4 - Combined License (COL) License Condition 2.D.(4)(d) Completion of Initial Criticality and Low-Power Tests2024-02-15015 February 2024 (Vegp), Unit 4 - Combined License (COL) License Condition 2.D.(4)(d) Completion of Initial Criticality and Low-Power Tests ND-23-0690, (Vegp), Unit 4 - Combined License (COL) License Condition 2.D.(3)(e) Completion of Pre-Critical Tests2024-02-0808 February 2024 (Vegp), Unit 4 - Combined License (COL) License Condition 2.D.(3)(e) Completion of Pre-Critical Tests ND-24-0019, Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2024-02-0101 February 2024 Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0912, Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2024-01-0202 January 2024 Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0881, Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-12-0404 December 2023 Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0817, (Vegp), Units 3 and 4 - Report of UFSAR Chapter 14 Changes to the Initial Test Program in Accordance with License Condition 2.D.(7)(a)2023-11-17017 November 2023 (Vegp), Units 3 and 4 - Report of UFSAR Chapter 14 Changes to the Initial Test Program in Accordance with License Condition 2.D.(7)(a) ND-23-0823, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-11-0303 November 2023 Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0723, (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-10-0404 October 2023 (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0697, (Vegp), Unit 4, Submittal of Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-09-0505 September 2023 (Vegp), Unit 4, Submittal of Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0669, (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-08-0707 August 2023 (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0205, (Vegp), Unit 3 - Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests2023-07-28028 July 2023 (Vegp), Unit 3 - Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests ND-23-0608, ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72) ND-23-0618, Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797)2023-07-20020 July 2023 Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797) ND-23-0609, Notification of Completion of All ITAAC2023-07-20020 July 2023 Notification of Completion of All ITAAC ND-23-0607, ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13) ND-22-0796, ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813) ND-23-0459, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587) ND-23-0162, ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165) ND-23-0483, ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4) ND-23-0552, Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624)2023-07-18018 July 2023 Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624) ND-23-0439, ITAAC Closure Notification on Completion of ITAAC 2.2.05.07a.i (Index Number 265)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.05.07a.i (Index Number 265) ND-23-0575, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588) ND-23-0610, ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603)2023-07-17017 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603) ND-23-0586, ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159)2023-07-17017 July 2023 ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159) ND-23-0406, ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498) ND-23-0573, ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497) ND-23-0476, ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355) ND-23-0499, ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700) ND-23-0606, ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557) ND-23-0601, ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719) ND-23-0594, ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629) ND-23-0446, ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250) ND-23-0603, ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831) ND-22-0816, ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19)2023-07-15015 July 2023 ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19) ND-23-0002, ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270) ND-23-0597, ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530) ND-23-0122, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668) ND-23-0121, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667) ND-23-0588, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78) ND-23-0394, ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703) ND-23-0543, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622) ND-23-0461, ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652) ND-23-0587, ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595) ND-22-0980, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75) ND-23-0111, ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646) ND-23-0581, ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220) 2024-04-26
[Table view] Category:Request for Code Relief or Alternative
[Table view] |
Text
A Southern Nuclear Southern Nuclear Operating Company, Inc.
3535 Colonnade Parkway Birmingham, AL 35243 Tel 205.992.7079 April 8, 2022 Docket Nos.: 52-025 ND-22-0242 52-026 10 CFR 50.55a U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Southern Nuclear Operating Company Vogtle Electric Generating Plant Units 3 and 4 Request for Alternative: Alternative Requirements for Main Turbine System Valve Testing (VEGP 3&4-IST-ALT-02)
Ladies and Gentlemen:
Pursuant to 10 CFR 50.55a(z)(1), Southern Nuclear Operating Company (SNC) requests NRC authorization to use an alternative to the requirements of 10 CFR 50.55a(f) and the ASME Operation and Maintenance of Nuclear Power Plants (OM) Code requirements for quarterly full stroke testing of main turbine system valves as currently identified in Revision 2 of the Vogtle Electric Generating Plant Units 3&4 Inservice Testing Program Plan - 1st Interval (SNC letter No.
ND-22-0254) submitted to NRC on April 7, 2022. The proposed alternative would establish partial stroke testing every six months consistent with the Vogtle Units 3 and 4 Turbine Maintenance and Inspection Program (UFSAR section 10.2.3.6, bullet 5). As a result of the changes made by this Alternative, the fail-safe test will become part of the existing Cold Shutdown stroke test. This request was discussed with NRC Staff during the December 13, 2021, pre-submittal public meeting.
The details of the 10 CFR 50.55a(z) request for an alternative are provided in Enclosure 1 of this letter.
Associated markups of the inservice testing program plan are provided in Enclosure 2 of this letter.
SNC requests the NRC authorize this proposed alternative by October 8, 2022, which is expected to be prior to the first Program Plan required quarterly full stroke test of these valves at power.
This letter contains no regulatory commitments. This letter has been reviewed and confirmed to contain no security-related information. Should you have any questions, please contact Ms. Amy Chamberlain at (205) 992-6361.
U.S. Nuclear Regulatory Commission ND-22-0242 Page 2 of 4 I declare under penalty of perjury that the foregoing is true and correct. Executed on the 8th day of April 2022.
Respectfully submitted, SOUTHERN NUCLEAR OPERATING COMPANY Amy C. Chamberlain Manager, Regulatory Affairs Southern Nuclear Operating Company : Request for Alternative: Alternative Requirements for Main Steam and Turbine System Valve Testing (VEGP 3&4-IST-ALT-02) : Markup of Vogtle Units 3 and 4 Inservice Testing Program Plan -
1st Interval
U.S. Nuclear Regulatory Commission ND-22-0242 Page 3 of 4 cc:
Southern Nuclear Operating Company / Georgia Power Company Mr. S. E. Kuczynski (w/o enclosures)
Mr. P. P. Sena III (w/o enclosures)
Mr. H. Nieh (w/o enclosures)
Mr. G. Chick Mr. S. Stimac Mr. P. Martino Mr. J. B. Williams Mr. D. L. McKinney (w/o enclosures)
Mr. T. W. Yelverton (w/o enclosures)
Mr. B. H. Whitley Ms. C. A. Gayheart Ms. M. Ronnlund Ms. J. M. Coleman Mr. C. T. Defnall Ms. A. C. Chamberlain Mr. S. Leighty Ms. K. Roberts Mr. J. Haswell Mr. A. S. Parton Mr. A. Nix Mr. T.M. Drouin Document Services RTYPE: VND.LI.L00 File AR.01.02.06 Nuclear Regulatory Commission Mr. M. King (w/o enclosures)
Mr. G. Bowman Ms. M. Bailey (w/o enclosures)
Ms. A. Veil Mr. V. Hall Mr. G.J. Khouri Mr. G. Armstrong Mr. C. Patel Mr. C. Santos Mr. B. Kemker Mr. J. Eargle Mr. C. J. Even Ms. N. C. Coovert Mr. C. Welch Mr. J. Gaslevic Mr. O. Lopez-Santiago Mr. M. Webb Mr. B. Gleaves
U.S. Nuclear Regulatory Commission ND-22-0242 Page 4 of 4 Nuclear Regulatory Commission (continued)
Mr. T. Fredette Ms. K. McCurry Mr. B. Davis Mr. J. Parent Mr. B. Griman Mr. P. OBryan State of Georgia Mr. R. Dunn Oglethorpe Power Corporation Mr. M. W. Price Mr. B. Brinkman Mr. E. Rasmussen Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Dalton Utilities Mr. T. Bundros Westinghouse Electric Company, LLC Mr. L. Oriani (w/o enclosures)
Mr. T. Rubenstein (w/o enclosures)
Mr. M. Corletti Mr. D. Hawkins Ms. S. Zwack Other Mr. S. W. Kline, Bechtel Power Corporation Ms. L. A. Matis, Tetra Tech NUS, Inc.
Dr. W. R. Jacobs, Jr., Ph.D., GDS Associates, Inc.
Mr. S. Roetger, Georgia Public Service Commission Ms. S. W. Kernizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. S. Blanton, Balch Bingham
Southern Nuclear Operating Company ND-22-0242 Enclosure 1 Vogtle Electric Generating Plant (VEGP) Units 3 and 4 Request for Alternative:
Alternative Requirements for Main Steam and Turbine System Valve Testing (VEGP 3&4-IST-ALT-02)
(This enclosure consists of 4 pages, including this cover page.)
ND-22-0242 Request for Alternative (VEGP 3&4-IST-ALT-02)
Plant Site-Unit: Vogtle Electric Generating Plant (VEGP) - Units 3 and 4 Interval-Interval Applies to the initial inservice test (IST) interval for Units 3 and 4 Dates:
Requested Date for Authorization is requested by October 8, 2022 Approval:
Specific alternative requested is applicable to Main Turbine System (MTS):
ASME Code
- Turbine stop valves: MTS-PL-V001A/B and MTS-PL-V003A/B, and Components
- Turbine control valves: MTS-PL-V002A/B and MTS-PL-V004A/B.
Affected:
These are Class N, Active, Category B valves.
Applicable ASME Operation and Maintenance of Nuclear Power Plants (OM)
Code Edition Code, 2012 Edition for 1st Inservice Test Interval and Addenda:
Applicable Code Quarterly exercise (ISTC-3510), full stroke exercise (ISTC-3521(a))
Requirements:
10 CFR 50.55a(z) allows for alternatives to the requirements when the licensee can demonstrate that: 1) the proposed alternative would provide an acceptable level of quality and safety; or 2) compliance with the specified requirements of this section would result in hardship or unusual difficulty without a compensating increase in the level of quality Reason for and safety.
Request: The proposed alternative test methodology and frequency provides an acceptable level of quality and safety, while reducing the risk of an unplanned turbine trip and associated potential challenges to safety systems.
Page 2 of 4
ND-22-0242 Request for Alternative (VEGP 3&4-IST-ALT-02)
Proposed Alternative:
In lieu of the Code requirement for full-stroke testing of these valves on a quarterly frequency per ISTC-3510 and ISTC-3521(a), it is proposed to establish partial stroke testing on a semi-annual basis (six-month frequency as identified in Code Case OMN-20).
Basis for Use:
The turbine stop and control valves close to perform the function of providing backup isolation in the event of a main steam line break (MSLB) or steam generator tube rupture with the single failure of a main steam isolation valve (MSIV) to mitigate the event (Bases for Technical Specification 3.7.2, Main Steam Line Flow Path Isolation Valves), and to prevent the generation of turbine missiles in the event of a turbine overspeed condition (UFSAR Section 10.2). When Westinghouse was designing the AP1000, the stroking of these valves was assumed, as documented in the DCD, to be informed by industry initiatives to minimize the chances of an unanticipated turbine trip (turbine valve testing is the most common cause of unplanned reactor trips), while maintaining the probability of generating a turbine missile at an appropriately low probability (see UFSAR Subsection 10.2.3.6). This testing frequency (every six months) is within the assumed testing Proposed frequency used in the PRA which demonstrated an acceptable overall Alternative and risk, including the use of these valves in their MSIV backup function.
Basis for Use: Additionally, the change from full-stroke to partial stroke exercising during operation minimizes the required power reduction (to 90% for partial stroke testing vs. to 75% for full stroke testing) and associated secondary transient which also contributes to reducing the risk of a turbine trip event. The UFSAR discussion of the turbine maintenance and inspection program in Subsection 10.2.3.6 indicates:
Turbine valve testing is performed at six-month intervals. The semi-annual testing frequency is based on nuclear industry experience that turbine-related tests are the most common cause of plant trips at power. Plant trips at power may lead to challenges of the safety-related systems. Evaluations show that the probability of turbine missile generation with a semi-annual valve test is less than the evaluation criteria.
The Unit 3 Turbine Maintenance and Inspection Program (submitted on July 9, 2020) identifies this testing at six-month intervals as partial stroke testing.
The partial stroke testing on a six-month frequency, provides an acceptable level of quality and safety. As such, SNC proposes this alternative to the OM Code under 10 CFR 50.55a(z)(1).
Note: Approval of this Alternative will require the fail safe test to be done in conjunction with the existing full stroke exercise on a Cold Shutdown frequency.
Page 3 of 4
ND-22-0242 Request for Alternative (VEGP 3&4-IST-ALT-02)
Duration of Proposed Through the end of the first Vogtle Unit 3 & Unit 4 IST interval Alternative:
- 1. Vogtle Electric Generating Plant Units 3&4 INSERVICE TESTING PROGRAM PLAN - 1st INTERVAL, Revision 2, submitted to NRC (via SNC letter No. ND-22-0254) on April 7, 2022.
References:
- 2. Vogtle Electric Generating Plant Units 3&4 TURBINE MAINTENANCE AND INSPECTION PROGRAM (ADAMS Accession No. ML20192A048) submitted to NRC on July 9, 2020
- 3. UFSAR Subsection 10.2.3.6, Maintenance and Inspection Program Plan (relative to turbine rotor integrity)
Status: Awaiting NRC authorization Page 4 of 4
Southern Nuclear Operating Company ND-22-0242 Enclosure 2 Vogtle Electric Generating Plant (VEGP) Units 3 and 4 Markup of Vogtle Units 3 and 4 Inservice Testing Program Plan - 1st Interval (This enclosure consists of 4 pages, including this cover page.)
ND-22-0242 Enclosure 2 Markup of Vogtle Unit 3 Inservice Testing Program Plan - 1st Interval Revise the MTS stop and control valve stroke testing Frequencies as follows:
MTS Valve ID Valve Valve Act. Drawing Required Code Dev. Plan Notes Description Class Aug Cat A/P Size Type Type & Coord Normal Safety Fail-Safe Test Freq SV3-MTS-PL-V001A N Y B A 28 GL EH SV3-MTS-M6-002 O C C* PI 2y
- Note 8 F-6 STCPSE QSA STC CS CSJ-MTS-1 Main Stop Valve #1 FST QCS SV3-MTS-PL-V001B N Y B A 28 GL EH SV3-MTS-M6-002 O C C* PI 2y
- Note 8 C-6 STCPSE QSA STC CS CSJ-MTS-1 Main Stop Valve #3 FST QCS SV3-MTS-PL-V002A N Y B A 28 GL EH SV3-MTS-M6-002 O C C* PI 2y
- Note 8 F-6 STCPSE QSA STC CS CSJ-MTS-1 Control Valve #1 FST QCS SV3-MTS-PL-V002B N Y B A 28 GL EH SV3-MTS-M6-002 O C C* PI 2y
- Note 8 C-6 STCPSE QSA STC CS CSJ-MTS-1 Control Valve #3 FST QCS SV3-MTS-PL-V003A N Y B A 28 GL EH SV3-MTS-M6-002 O C C* PI 2y
- Note 8 E-6 STCPSE QSA STC CS CSJ-MTS-1 Main Stop Valve #2 FST QCS SV3-MTS-PL-V003B N Y B A 28 GL EH SV3-MTS-M6-002 O C C* PI 2y
- Note 8 D-6 STCPSE QSA STC CS CSJ-MTS-1 Main Stop Valve #4 FST QCS SV3-MTS-PL-V004A N Y B A 28 GL EH SV3-MTS-M6-002 O C C* PI 2y
- Note 8 E-6 STCPSE QSA STC CS CSJ-MTS-1 Control Valve #2 FST QCS SV3-MTS-PL-V004B N Y B A 28 GL EH SV3-MTS-M6-002 O C C* PI 2y
- Note 8 D-6 STCPSE QSA STC CS CSJ-MTS-1 Control Valve #4 FST QCS Page 2 of 4
ND-22-0242 Enclosure 2 Request for Alternative (VEGP 3&4-IST-ALT-02)
Unit 3 IST Program Plan markups shown - Unit 4 markups would show identical changes Select Table Notes
- 8. MTS-V001A/B, V002A/B, V003A/B V004A/B fail closed on loss of hydraulic pressure, but not on loss of electrical power to the fast-acting solenoid valves.
Select IST Program Plan Legend information (for reviewer information):
Class N - non-safety related Aug Y - Augmented scope (not required by ASME OM Code)
Cat. B - OM Code Category B Valve (see OM Code)
A/P A - Active valve Valve Type GL - Globe Valve Act. Type AO - Air Operated actuator Act. Type EH - Electro-Hydraulic Operated actuator Position O - Open Position C - Closed Required Test PI - Remote Position Indication Verification Required Test PSE - Part-Stroke Exercise (new)
Required Test STC - Stroke Time Closed test Required Test FST - Fail-Safe Test Freq 2y - Two-year frequency Freq Q - Quarterly frequency Freq SA -Semi-Annually or six-month frequency (new)
Freq CS - Cold shutdown frequency Page 3 of 4
ND-22-0242 Markup of Vogtle Unit 3 Inservice Testing Program Plan - 1st Interval 9.0 COLD SHUTDOWN TESTING JUSTIFICATIONS Revise CSJ-MTS-1 as shown:
COLD SHUTDOWN JUSTIFICATION CSJ-MTS-1 SYSTEM: Main Turbine VALVE(S): SV3/4-MTS-PL-V001A/B, V002A/B, V003A/B, V004A/B CATEGORY: B CLASS: N FUNCTION: These valves close to provide a backup to the MSIVs QUARTERLY TEST REQUIREMENT: Exercise and stroke time closed and fail-safe test.
COLD SHUTDOWN JUSTIFICATION: The valves are exercised quarterly using the non-safety turbine valve test controls. This test circuit does not include, the skid-mounted fast acting solenoid valves credited to perform the required function of closing these valves to back up the MSIVs. The fast-acting solenoid valves cannot be tested at power, as the turbine controls design assumed these valves would be tested on a Cold Shutdown frequency as documented in Table 3.9-16 of the DCD, and therefore does not support testing of the fast-acting solenoids as part of the online valve testing capability. Operation of the fast-acting solenoids at power would result in a turbine trip.
QUARTERLY PARTIAL STROKE TESTING: None. The safety function solenoid valves do not have the capability for partial stroking.
COLD SHUTDOWN TESTING: Exercise and stroke time closed and fail-safe test the turbine bypass valves using the fast-acting solenoid valves.
Page 4 of 4