Text
3400 Innovation Ct.
- Janesville, WI 53546
- 877.512.6554
- info@shinemed.com
- www.SHINEtechnologies.com March 9, 2022 2022-SMT-0036 10 CFR 50.30 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
References:
(1) SHINE Medical Technologies, LLC letter to the NRC, SHINE Medical Technologies, LLC Application for an Operating License, dated July 17, 2019 (ML19211C143)
(2) NRC letter to SHINE Medical Technologies, LLC, SHINE Medical Technologies, LLC - Request for Additional Information Related to the Radiation Monitoring System(s) (EPID No. L-2019-NEW-0004), dated January 11, 2022 (ML22007A217)
SHINE Technologies, LLC Application for an Operating License Supplement No. 18 and Response to Request for Additional Information Pursuant to 10 CFR Part 50.30, SHINE Technologies, LLC (SHINE) submitted an application for an operating license for a medical isotope production facility to be located in Janesville, Wisconsin via Reference 1. Via Reference 2, the NRC staff determined that additional information was required to enable the staffs continued review of the SHINE operating license application.
provides the SHINE Final Safety Analysis Report (FSAR) Change Summary, identifying changes to the SHINE FSAR not related to the SHINE responses to the NRC staffs request for additional information.
provides the SHINE response to the NRC staffs request for additional information.
If you have any questions, please contact Mr. Jeff Bartelme, Director of Licensing, at 608/210-1735.
I declare under the penalty of perjury that the foregoing is true and correct.
Executed on March 9, 2022.
Very truly yours, James Costedio Vice President of Regulatory Affairs and Quality SHINE Technologies, LLC Docket No. 50-608 Enclosures cc:
Project Manager, USNRC SHINE General Counsel Supervisor, Radioactive Materials Program, Wisconsin Division of Public Health
Page 1 of 1 ENCLOSURE 1 SHINE TECHNOLOGIES, LLC SHINE TECHNOLOGIES, LLC APPLICATION FOR AN OPERATING LICENSE SUPPLEMENT NO. 18 AND RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION FINAL SAFETY ANALYSIS REPORT CHANGE
SUMMARY
Summary Description of Changes FSAR Impacts Update to correct inaccuracies in TRPS and ESFAS self-testing descriptions, and to provide clarification on the use of self-testing and technical specifications surveillances in demonstrating operability.
Section 7.4, Section 7.5, Section 7.9 A markup of the Final Safety Analysis Report (FSAR) changes is provided as Attachment 1.
ENCLOSURE 1 ATTACHMENT 1 SHINE TECHNOLOGIES, LLC SHINE TECHNOLOGIES, LLC APPLICATION FOR AN OPERATING LICENSE SUPPLEMENT NO. 18 AND RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION FINAL SAFETY ANALYSIS REPORT CHANGE
SUMMARY
FINAL SAFETY ANALYSIS REPORT MARKUP
7DUJHW6ROXWLRQ9HVVHO
&KDSWHU+/-,QVWUXPHQWDWLRQDQG&RQWURO6\\VWHPV 5HDFWLYLW\\3URWHFWLRQ6\\VWHP 6+,1(0HGLFDO7HFKQRORJLHV
5HY
7KH7536FRQWDLQVFDSDELOLWLHVIRULQVHUYLFHWHVWLQJIRUWKRVHIXQFWLRQVWKDWFDQQRWEHWHVWHG
ZKLOHWKH,8LVRXWRIVHUYLFH6XEVHFWLRQ
6WUXFWXUHVV\\VWHPVDQGFRPSRQHQWVWKDWFRPSULVHDGLYLVLRQDUHSK\\VLFDOO\\VHSDUDWHGWRUHWDLQ
WKHFDSDELOLW\\RISHUIRUPLQJWKHUHTXLUHGVDIHW\\IXQFWLRQVGXULQJDGHVLJQEDVLVDFFLGHQW
6XEVHFWLRQ
5HGXQGDQF\\ZLWKLQWKH7536DVGHVFULEHGLQ6XEVHFWLRQ FRQVLVWVRIWKUHHGLYLVLRQVRI
LQSXWSURFHVVLQJDQGWULSGHWHUPLQDWLRQDQGWZRGLYLVLRQVRIDFWXDWLRQORJLFDUUDQJHGVXFKWKDWQR
VLQJOHIDLOXUHFDQSUHYHQWDVDIHW\\DFWXDWLRQZKHQUHTXLUHGDQGQRVLQJOHIDLOXUHLQDVLQJOH
PHDVXUHPHQWFKDQQHOFDQJHQHUDWHDQXQQHFHVVDU\\VDIHW\\DFWXDWLRQ6XEVHFWLRQ 7KLV
ZDVYDOLGDWHGE\\WKHSHUIRUPDQFHRIDVLQJOHIDLOXUHDQDO\\VLVRIWKH7536SHUIRUPHGLQ
DFFRUGDQFHZLWK,QVWLWXWHRI(OHFWULFDODQG(OHFWURQLFV(QJLQHHUV,(((6WDQGDUG
,(((DVGHVFULEHGLQ6XEVHFWLRQ
$FKDQQHORI7536FDQEHWDNHQRXWRIVHUYLFHE\\SODFLQJWKHFKDQQHOLQWULSRUXVLQJWKH
PDLQWHQDQFHE\\SDVVIXQFWLRQDVGHVFULEHGLQ6XEVHFWLRQ $FKDQQHOFDQEHWDNHQWRWULS
ZLWKRXWDQDGYHUVHLPSDFWRQUHGXQGDQF\\DVGHVFULEHGLQ6XEVHFWLRQ
7KHPDLQWHQDQFHE\\SDVVIXQFWLRQDOORZVDQLQGLYLGXDOVDIHW\\IXQFWLRQPRGXOHWREHUHPRYHG
IURPVHUYLFHIRUXSWRWZRKRXUVLQDFFRUGDQFHZLWKWKHWHFKQLFDOVSHFLILFDWLRQVIRUWKHSXUSRVH
RISHUIRUPLQJUHTXLUHGWHFKQLFDOVSHFLILFDWLRQVXUYHLOODQFHWHVWLQJ6XEVHFWLRQ $WLPH
OLPLWRIWZRKRXUVLVDFFHSWDEOHEDVHGRQWKHVPDOODPRXQWRIWLPHWKHFKDQQHOFRXOGEHLQ
E\\SDVVWKHFRQWLQXDODWWHQGDQFHE\\RSHUDWLRQVRUPDLQWHQDQFHSHUVRQQHOGXULQJWKHWHVWWKH
FRQWLQXHGRSHUDELOLW\\RIWKHUHGXQGDQWFKDQQHOVDQGWKHORZOLNHOLKRRGWKDWDQDFFLGHQWZRXOG
RFFXUGXULQJWKHWZRKRXUWLPHSHULRG%\\DOORZLQJDVLQJOH6)0PRGXOHWREHSODFHGLQ
PDLQWHQDQFHE\\SDVVLQDFFRUGDQFHZLWKWKHWHFKQLFDOVSHFLILFDWLRQVWHFKQLFDOVSHFLILFDWLRQV
VXUYHLOODQFHVFDQEHSHUIRUPHGWRYHULI\\WKHRSHUDELOLW\\RI7536FRPSRQHQWVGXULQJV\\VWHP
RSHUDWLRQZKLFKVXSSRUWVLQVHUYLFHWHVWDELOLW\\
6HOIWHVWIHDWXUHVDUHSURYLGHGIRUFRPSRQHQWVWKDWGRQRWKDYHVHWSRLQWVRUWXQDEOHSDUDPHWHUV
6XEVHFWLRQ 7KHGLVFUHWHORJLFRIWKHDFWXDWLRQDQGSULRULW\\ORJLF$3/RIWKH(,0GRHV
QRWKDYHVHOIWHVWFDSDELOLW\\EXWLVLQVWHDGIXQFWLRQDOO\\WHVWHG6XEVHFWLRQ &DOLEUDWLRQ
WHVWLQJDQGGLDJQRVWLFVDUHDGGUHVVHGLQ6HFWLRQRI7RSLFDO5HSRUW75-³'HVLJQ
RIWKH+LJKO\\,QWHJUDWHG3URWHFWLRQ6\\VWHP3ODWIRUP'1X6FDOH6HOIWHVWLQJFDSDELOLWLHV
SURYLGHLQGLFDWLRQRIFRPSRQHQWGHJUDGDWLRQDQGIDLOXUHZKLFKDOORZVDFWLRQWREHWDNHQWR
HQVXUHWKDWQRVLQJOHIDLOXUHUHVXOWVLQWKHORVVRIWKHSURWHFWLRQIXQFWLRQ
3URWHFWLRQ6\\VWHP,QGHSHQGHQFH 6+,1('HVLJQ&ULWHULRQ+/-7KHSURWHFWLRQV\\VWHPVDUHGHVLJQHGWRHQVXUHWKDWWKHHIIHFWV
RIQDWXUDOSKHQRPHQDDQGRIQRUPDORSHUDWLQJPDLQWHQDQFHWHVWLQJDQGSRVWXODWHG
DFFLGHQWFRQGLWLRQVRQUHGXQGDQWFKDQQHOVGRQRWUHVXOWLQORVVRIWKHSURWHFWLRQIXQFWLRQRU
DUHGHPRQVWUDWHGWREHDFFHSWDEOHRQVRPHRWKHUGHILQHGEDVLV'HVLJQWHFKQLTXHVVXFKDV
IXQFWLRQDOGLYHUVLW\\RUGLYHUVLW\\LQFRPSRQHQWGHVLJQDQGSULQFLSOHVRIRSHUDWLRQDUHXVHGWR
WKHH[WHQWSUDFWLFDOWRSUHYHQWORVVRIWKHSURWHFWLRQIXQFWLRQ
7KH7536FRQWURODQGORJLFIXQFWLRQVRSHUDWHLQVLGHRIWKHIDFLOLW\\FRQWUROURRPZKHUHWKH
HQYLURQPHQWLVPLOGQRWH[SRVHGWRWKHLUUDGLDWLRQSURFHVVDQGLVSURWHFWHGIURPHDUWKTXDNHV
WRUQDGRHVDQGIORRGV6XEVHFWLRQV DQG7KH7536VWUXFWXUHVV\\VWHPVDQG
7DUJHW6ROXWLRQ9HVVHO
&KDSWHU+/-,QVWUXPHQWDWLRQDQG&RQWURO6\\VWHPV 5HDFWLYLW\\3URWHFWLRQ6\\VWHP 6+,1(0HGLFDO7HFKQRORJLHV
5HY
7536&ULWHULRQ+/-0HFKDQLVPVIRUGHOLEHUDWHRSHUDWRULQWHUYHQWLRQLQWKH7536VWDWXVRU
LWVIXQFWLRQVVKDOOQRWEHFDSDEOHRISUHYHQWLQJWKHLQLWLDWLRQRI7536
$QHQDEOHQRQVDIHW\\VZLWFKZKHQHQDEOHGDOORZVDIDFLOLW\\RSHUDWRUWRFRQWUROWKHRXWSXWVWDWHRI
WKH7536ZLWKDKDUGZLUHGELQDU\\FRQWUROVLJQDOIURPWKHQRQVDIHW\\UHODWHGFRQWUROV,IWKHHQDEOH
QRQVDIHW\\VZLWFKLVDFWLYHDQGQRDXWRPDWLFVDIHW\\DFWXDWLRQRUPDQXDOVDIHW\\DFWXDWLRQVLJQDOV
DUHSUHVHQWWKHRSHUDWRULVFDSDEOHRIHQHUJL]LQJRUGHHQHUJL]LQJDQ\\(,0RXWSXWVXVLQJWKH
QRQVDIHW\\UHODWHGKDUGZLUHGFRQWUROVLJQDOV6XEVHFWLRQ $GGLWLRQDOO\\VDIHW\\UHODWHG
VLJQDOVDUHSULRULWL]HGRYHUQRQVDIHW\\UHODWHGVLJQDOV6XEVHFWLRQ
(TXLSPHQW4XDOLILFDWLRQ 7536&ULWHULRQ+/-7KHHIIHFWVRIHOHFWURPDJQHWLFLQWHUIHUHQFHUDGLRIUHTXHQF\\LQWHUIHUHQFH
(0,5),DQGSRZHUVXUJHVVXFKDVKLJKHQHUJ\\IDXOWVDQGOLJKWQLQJRQWKH7536
LQFOXGLQJ)3*$EDVHGGLJLWDOSRUWLRQVVKDOOEHDGHTXDWHO\\DGGUHVVHG
7536UDFNPRXQWHGHTXLSPHQWLVLQVWDOOHGLQDPLOGRSHUDWLQJHQYLURQPHQWDQGLVGHVLJQHGWR
PHHWWKHHQYLURQPHQWDOFRQGLWLRQVGHVFULEHGLQ6XEVHFWLRQ 5DFNPRXQWHG7536
HTXLSPHQWLVWHVWHGWRDSSURSULDWHVWDQGDUGVWRVKRZWKDWWKHHIIHFWVRI(0,5),DQGSRZHU
VXUJHVDUHDGHTXDWHO\\DGGUHVVHG7KLVWHVWLQJLQFOXGHVHPLVVLRQVWHVWLQJVXVFHSWLELOLW\\WHVWLQJ
DQGVXUJHZLWKVWDQGWHVWLQJ$SSURSULDWHJURXQGLQJRIWKH7536LVSHUIRUPHGLQDFFRUGDQFHZLWK
6HFWLRQRI,(((6WDQGDUG,(((E
6XUYHLOODQFH 7536&ULWHULRQ+/-(TXLSPHQWLQWKH7536IURPWKHLQSXWFLUFXLWU\\WRRXWSXWDFWXDWLRQ
FLUFXLWU\\VKDOOEHGHVLJQHGWRDOORZWHVWLQJFDOLEUDWLRQDQGLQVSHFWLRQWRHQVXUHRSHUDELOLW\\,I
WHVWLQJLVUHTXLUHGRUFDQEHSHUIRUPHGDVDQRSWLRQGXULQJRSHUDWLRQWKH7536VKDOOUHWDLQ
WKHFDSDELOLW\\WRDFFRPSOLVKLWVVDIHW\\IXQFWLRQZKLOHXQGHUWHVW
7KH7536GHVLJQVXSSRUWVWHVWLQJPDLQWHQDQFHDQGFDOLEUDWLRQDVGHVFULEHGLQ
6XEVHFWLRQV DQG6XUYHLOODQFHWHVWLQJSHUIRUPHGXVLQJWKHPDLQWHQDQFHE\\SDVV
FDSDELOLW\\GXULQJRSHUDWLRQLVFRQWUROOHGLQDFFRUGDQFHZLWKWKHWHFKQLFDOVSHFLILFDWLRQVWRHQVXUH
WKDWWKH7536LVFDSDEOHRISHUIRUPLQJLWVVDIHW\\IXQFWLRQVZKHQUHTXLUHG6XEVHFWLRQ
6HOIWHVWLQJIHDWXUHVSURYLGHIRUPRQLWRULQJDVGHVFULEHGLQ6XEVHFWLRQ WRSURYLGH
LQGLFDWLRQWRWKHRSHUDWRULIFRQGLWLRQVH[LVWWKDWFRXOGFKDOOHQJHRSHUDELOLW\\RIWKHHTXLSPHQW
7536&ULWHULRQ+/-7HVWLQJFDOLEUDWLRQDQGLQVSHFWLRQVRIWKH7536VKDOOEHVXIILFLHQWWR
VKRZWKDWRQFHSHUIRUPHGWKH\\FRQILUPWKDWVXUYHLOODQFHWHVWDQGVHOIWHVWIHDWXUHVDGGUHVV
IDLOXUHGHWHFWLRQVHOIWHVWIHDWXUHVDQGDFWLRQVWDNHQXSRQIDLOXUHGHWHFWLRQ
7KH7536GHVLJQVXSSRUWVWHVWLQJPDLQWHQDQFHDQGFDOLEUDWLRQDVGHVFULEHGLQ
6XEVHFWLRQV DQG(QGWRHQGWHVWLQJRIWKHHQWLUH7536SODWIRUPFDQEH
SHUIRUPHGWKURXJKRYHUODSWHVWLQJ$OO7536FRPSRQHQWVKDYHVHOIWHVWLQJFDSDELOLWLHVH[FHSW
WKHGLVFUHWH$3/RIWKH(,0SRZHUVXSSOLHVDQGKDUGZLUHGFRPPXQLFDWLRQVEHWZHHQWKH7536
DQG(6)$6YLDWKHLUUHVSHFWLYH6%90VZKLFKLVDUHIXQFWLRQDOO\\WHVWHG7KH7536FRQWLQXRXVO\\
SURYLGHVUHGXQGDQWLQGLFDWLRQRIVHOIWHVWLQJUHVXOWVWRWKH3,&6WRLQGLFDWHWRRSHUDWRUVWKDWWKH
7536LVRSHUDWLQJFRUUHFWO\\IROORZLQJWHVWLQJFDOLEUDWLRQRULQVSHFWLRQV
7DUJHW6ROXWLRQ9HVVHO
&KDSWHU+/-,QVWUXPHQWDWLRQDQG&RQWURO6\\VWHPV 5HDFWLYLW\\3URWHFWLRQ6\\VWHP 6+,1(0HGLFDO7HFKQRORJLHV
5HY
RQHRXWRIWZRRUWZRRXWRIWKUHHFRLQFLGHQWYRWLQJDVLQJOHIDLOXUHRIWKHVDPH6)0LQDQRWKHU
GLYLVLRQZRXOGGHIHDWWKHVDIHW\\IXQFWLRQ3ODFLQJDVLQJOH6)0LQPDLQWHQDQFHE\\SDVVLVDOORZHG
E\\WKHWHFKQLFDOVSHFLILFDWLRQVIRUXSWRWZRKRXUVIRUWKHSXUSRVHRISHUIRUPLQJUHTXLUHG
WHFKQLFDOVSHFLILFDWLRQVXUYHLOODQFHWHVWLQJ
- LWKDQ6)0¶V226VZLWFKLQWKH226SRVLWLRQDQGWKHDVVRFLDWHGWULSE\\SDVVVZLWFKLQHLWKHU
WKHWULSRUE\\SDVVSRVLWLRQWKHLQSXWFKDQQHOVDVVRFLDWHGZLWKWKH6)0DUHLQRSHUDEOH
7HVWLQJ&DSDELOLW\\
7HVWLQJRIWKH7536FRQVLVWVRIWKHLQVHUYLFHVHOIWHVWLQJFDSDELOLWLHVRIWKH+,36SODWIRUPDQG
SHULRGLFVXUYHLOODQFHWHVWLQJ
(QGWRHQGWHVWLQJRIWKHHQWLUH+,36SODWIRUPLVSHUIRUPHGWKURXJKRYHUODSWHVWLQJ,QGLYLGXDO
VHOIWHVWVLQWKHYDULRXVFRPSRQHQWVRIWKH7536HQVXUHWKDWWKHHQWLUHFRPSRQHQWLVIXQFWLRQLQJ
FRUUHFWO\\6HOIWHVWIHDWXUHVDUHSURYLGHGIRUFRPSRQHQWVWKDWGRQRWKDYHVHWSRLQWVRUWXQDEOH
SDUDPHWHUV$OO7536FRPSRQHQWVH[FHSWWKHGLVFUHWH$3/RIWKH(,0KDYHVHOIWHVWLQJ
FDSDELOLWLHVWKDWHQVXUHWKHLQIRUPDWLRQSDVVHGRQWRWKHIROORZLQJVWHSLQWKHVLJQDOSDWKLV
FRUUHFW6HOIWHVWLQJLVXVHGWRGHPRQVWUDWHRSHUDELOLW\\RIFRPSRQHQWVIURPWKHVHQVRULQSXWWR
WKHRXWSXWVZLWFKLQJORJLFH[FHSWIRUWKHGLVFUHWHORJLFRIWKH$3/SRZHUVXSSOLHVDQG
KDUGZLUHGFRPPXQLFDWLRQVEHWZHHQWKH7536DQG(6)$6YLDWKHLUUHVSHFWLYH6%90V
7KHGLVFUHWHORJLFRIWKH$3/RIWKH(,0GRHVQRWKDYHVHOIWHVWFDSDELOLW\\EXWLVLQVWHDG
IXQFWLRQDOO\\WHVWHG7KLVIXQFWLRQDOWHVWLQJFRQVLVWVRISHULRGLFVLPXODWHGDXWRPDWLFDQGPDQXDO
DFWXDWLRQVWRYHULI\\WKHIXQFWLRQDOLW\\RIWKH$3/DQGWKHPDQXDODFWXDWLRQSXVKEXWWRQV7KH$3/
WHVWYHULILHVWKHRSHUDELOLW\\RIWKHGLVFUHWHSULRULW\\ORJLFFLUFXLWVRIWKH75367KHVXUYHLOODQFH
IUHTXHQF\\RIWKH$3/WHVWLVDFFHSWDEOHEDVHGRQWKHEXLOWLQUHGXQGDQF\\DQGQRWLILFDWLRQRI
IDLOXUHVZLWKLQWKH7536
7KHRSHUDELOLW\\RIWKHSRZHUVXSSOLHVZLWKLQWKH7536FDELQHWVLVGHPRQVWUDWHGE\\FKHFNLQJWKH
YROWDJHVRIWKHSRZHUVXSSOLHVDWDIUHTXHQF\\FRQVLVWHQWZLWKWKHJXLGDQFHSURYLGHGLQ$PHULFDQ
1DWLRQDO6WDQGDUGV,QVWLWXWH$PHULFDQ1XFOHDU6RFLHW\\$16,$167KH
'HYHORSPHQWRI7HFKQLFDO6SHFLILFDWLRQVIRU5HVHDUFK5HDFWRUV$16,$16
7KHRSHUDELOLW\\RIKDUGZLUHGFRPPXQLFDWLRQVEHWZHHQWKH7536DQG(6)$6YLDWKHLUUHVSHFWLYH
6%90VLVGHPRQVWUDWHGYLDIXQFWLRQDOWHVWLQJDWDIUHTXHQF\\FRQVLVWHQWZLWKWKDWRIWKHLQSXW
GHYLFHVGHVFULEHGEHORZ
7HVWLQJRILQSXWGHYLFHVFRQVLVWVRIFKDQQHOFKHFNVFKDQQHOWHVWVDQGFKDQQHOFDOLEUDWLRQV
&KDQQHOFKHFNVDUHSHUIRUPHGZKLOHWKHFKDQQHOLVLQVHUYLFH&KDQQHOWHVWVDQGFKDQQHO
FDOLEUDWLRQVPD\\EHSHUIRUPHGZKLOHWKH,8LVLQDPRGHZKHUHWKHFKDQQHOLVUHTXLUHGWREH
RSHUDEOHLHLQVHUYLFHE\\SODFLQJWKHDVVRFLDWHG6)0LQPDLQWHQDQFHE\\SDVV
6XEVHFWLRQ &KDQQHOWHVWVDQGFKDQQHOFDOLEUDWLRQVIRULQSXWVSURYLGHGWRDQ6)0PD\\
DOVREHSHUIRUPHGZKHQWKHFKDQQHOLVQRWUHTXLUHGWREHRSHUDEOH&KDQQHOWHVWVRILQSXWV
SURYLGHGWRDQ+:0DUHSHUIRUPHGZKHQWKHFKDQQHOLVQRWUHTXLUHGWREHRSHUDEOHVLQFH
+:0VDUHQRWSURYLGHGZLWKPDLQWHQDQFHE\\SDVVFDSDELOLWLHV7KHFKDQQHOFKHFNVFKDQQHO
WHVWVDQGFKDQQHOFDOLEUDWLRQVGHPRQVWUDWHRSHUDELOLW\\RIWKHFKDQQHOIURPWKHILHOGLQVWUXPHQW
WKURXJKWKH6)0HQGLQJDWWKHLQSXWWRWKH6%90RU6%0&KDQQHOFKHFNVFKDQQHOWHVWVDQG
FKDQQHOFDOLEUDWLRQVDUHSHUIRUPHGDWIUHTXHQFLHVFRQVLVWHQWZLWKWKHJXLGDQFHSURYLGHGLQ
$16,$16$16,$16
(QJLQHHUHG6DIHW\\)HDWXUHV
&KDSWHU+/-,QVWUXPHQWDWLRQDQG&RQWURO6\\VWHPV
$FWXDWLRQ6\\VWHP 6+,1(0HGLFDO7HFKQRORJLHV
5HY
6WUXFWXUHVV\\VWHPVDQGFRPSRQHQWVWKDWFRPSULVHDGLYLVLRQDUHSK\\VLFDOO\\VHSDUDWHGWRUHWDLQ
WKHFDSDELOLW\\RISHUIRUPLQJWKHUHTXLUHGVDIHW\\IXQFWLRQVGXULQJDGHVLJQEDVLVDFFLGHQW
6XEVHFWLRQ
5HGXQGDQF\\ZLWKLQWKH(6)$6DVGHVFULEHGLQ6XEVHFWLRQ FRQVLVWVRIWZRRUWKUHH
GLYLVLRQVRILQSXWSURFHVVLQJDQGWULSGHWHUPLQDWLRQGHSHQGHQWRQWKHPRQLWRUHGYDULDEOHDQG
WZRGLYLVLRQVRIDFWXDWLRQORJLFDUUDQJHGVXFKWKDWQRVLQJOHIDLOXUHFDQSUHYHQWDVDIHW\\DFWXDWLRQ
ZKHQUHTXLUHG6XEVHFWLRQ 7KLVZDVYDOLGDWHGE\\WKHSHUIRUPDQFHRIDVLQJOHIDLOXUH
DQDO\\VLVRIWKH(6)$6SHUIRUPHGLQDFFRUGDQFHZLWK,(((6WDQGDUG,(((DV
GHVFULEHGLQ6XEVHFWLRQ
$FKDQQHORI(6)$6FDQEHWDNHQRXWRIVHUYLFHE\\SODFLQJWKHFKDQQHOLQWULSRUXVLQJWKH
PDLQWHQDQFHE\\SDVVIXQFWLRQDVGHVFULEHGLQ6XEVHFWLRQ $FKDQQHOFDQEHWDNHQWRWULS
ZLWKRXWDQDGYHUVHLPSDFWRQUHGXQGDQF\\DVGHVFULEHGLQ6XEVHFWLRQ
7KHPDLQWHQDQFHE\\SDVVIXQFWLRQDOORZVDQLQGLYLGXDOVDIHW\\IXQFWLRQPRGXOHWREHUHPRYHG
IURPVHUYLFHLQDFFRUGDQFHZLWKWKHWHFKQLFDOVSHFLILFDWLRQVIRUWKHSXUSRVHRISHUIRUPLQJ
UHTXLUHGWHFKQLFDOVSHFLILFDWLRQVXUYHLOODQFHWHVWLQJ6XEVHFWLRQ $WLPHOLPLWRIWZRKRXUV
LVDFFHSWDEOHEDVHGRQWKHVPDOODPRXQWRIWLPHWKHFKDQQHOFRXOGEHLQE\\SDVVWKHFRQWLQXDO
DWWHQGDQFHE\\RSHUDWLRQVRUPDLQWHQDQFHSHUVRQQHOGXULQJWKHWHVWWKHFRQWLQXHGRSHUDELOLW\\RI
WKHUHGXQGDQWFKDQQHOVDQGWKHORZOLNHOLKRRGWKDWDQDFFLGHQWZRXOGRFFXUGXULQJWKHWZR
KRXUWLPHSHULRG%\\DOORZLQJDVLQJOH6)0PRGXOHWREHSODFHGLQPDLQWHQDQFHE\\SDVVLQ
DFFRUGDQFHZLWKWKHWHFKQLFDOVSHFLILFDWLRQVWHFKQLFDOVSHFLILFDWLRQVVXUYHLOODQFHVFDQEH
SHUIRUPHGWRYHULI\\WKHRSHUDELOLW\\RI(6)$6FRPSRQHQWVGXULQJV\\VWHPRSHUDWLRQZKLFK
VXSSRUWVLQVHUYLFHWHVWDELOLW\\
6HOIWHVWIHDWXUHVDUHSURYLGHGIRUFRPSRQHQWVWKDWGRQRWKDYHVHWSRLQWVRUWXQDEOHSDUDPHWHUV
6XEVHFWLRQ 7KHGLVFUHWHORJLFRIWKHDFWXDWLRQDQGSULRULW\\ORJLF$3/RIWKH(,0GRHV
QRWKDYHVHOIWHVWFDSDELOLW\\EXWLVLQVWHDGIXQFWLRQDOO\\WHVWHG6XEVHFWLRQ &DOLEUDWLRQ
WHVWLQJDQGGLDJQRVWLFVDUHDGGUHVVHGLQ6HFWLRQRI7RSLFDO5HSRUW 75--
1X6FDOH6HOIWHVWLQJFDSDELOLWLHVSURYLGHLQGLFDWLRQRIFRPSRQHQWGHJUDGDWLRQDQG
IDLOXUHZKLFKDOORZVDFWLRQWREHWDNHQWRHQVXUHWKDWQRVLQJOHIDLOXUHUHVXOWVLQWKHORVVRIWKH
SURWHFWLRQIXQFWLRQ
3URWHFWLRQ6\\VWHP,QGHSHQGHQFH 6+,1('HVLJQ&ULWHULRQ+/-7KHSURWHFWLRQV\\VWHPVDUHGHVLJQHGWRHQVXUHWKDWWKHHIIHFWV
RIQDWXUDOSKHQRPHQDDQGRIQRUPDORSHUDWLQJPDLQWHQDQFHWHVWLQJDQGSRVWXODWHG
DFFLGHQWFRQGLWLRQVRQUHGXQGDQWFKDQQHOVGRQRWUHVXOWLQORVVRIWKHSURWHFWLRQIXQFWLRQRU
DUHGHPRQVWUDWHGWREHDFFHSWDEOHRQVRPHRWKHUGHILQHGEDVLV'HVLJQWHFKQLTXHVVXFKDV
IXQFWLRQDOGLYHUVLW\\RUGLYHUVLW\\LQFRPSRQHQWGHVLJQDQGSULQFLSOHVRIRSHUDWLRQDUHXVHGWR
WKHH[WHQWSUDFWLFDOWRSUHYHQWORVVRIWKHSURWHFWLRQIXQFWLRQ
7KH(6)$6FRQWURODQGORJLFIXQFWLRQVRSHUDWHLQVLGHRIWKHIDFLOLW\\FRQWUROURRPZKHUHWKH
HQYLURQPHQWLVPLOGQRWH[SRVHGWRWKHLUUDGLDWLRQSURFHVVDQGLVSURWHFWHGIURPHDUWKTXDNHV
WRUQDGRHVDQGIORRGV6XEVHFWLRQV DQG7KH(6)$6VWUXFWXUHVV\\VWHPVDQG
FRPSRQHQWVWKDWFRPSULVHDGLYLVLRQDUHSK\\VLFDOO\\VHSDUDWHGWRUHWDLQWKHFDSDELOLW\\RI
SHUIRUPLQJWKHUHTXLUHGVDIHW\\IXQFWLRQVGXULQJDGHVLJQEDVLVDFFLGHQW'LYLVLRQLQGHSHQGHQFH
LVPDLQWDLQHGWKURXJKRXWH[WHQGLQJIURPWKHVHQVRUWRWKHGHYLFHVDFWXDWLQJWKHSURWHFWLYH
IXQFWLRQ6XEVHFWLRQ
(QJLQHHUHG6DIHW\\)HDWXUHV
&KDSWHU+/-,QVWUXPHQWDWLRQDQG&RQWURO6\\VWHPV
$FWXDWLRQ6\\VWHP 6+,1(0HGLFDO7HFKQRORJLHV
5HY
$QHQDEOHQRQVDIHW\\VZLWFKZKHQHQDEOHGDOORZVDIDFLOLW\\RSHUDWRUWRFRQWUROWKHRXWSXWVWDWHRI
WKH(6)$6ZLWKDKDUGZLUHGELQDU\\FRQWUROVLJQDOIURPWKHQRQVDIHW\\UHODWHGFRQWUROV,IWKH
HQDEOHQRQVDIHW\\VZLWFKLVDFWLYHDQGQRDXWRPDWLFVDIHW\\DFWXDWLRQRUPDQXDOVDIHW\\DFWXDWLRQ
VLJQDOVDUHSUHVHQWWKHRSHUDWRULVFDSDEOHRIHQHUJL]LQJRUGHHQHUJL]LQJDQ\\(,0RXWSXWVXVLQJ
WKHQRQVDIHW\\UHODWHGKDUGZLUHGFRQWUROVLJQDOV6XEVHFWLRQ $GGLWLRQDOO\\VDIHW\\UHODWHG
VLJQDOVDUHSULRULWL]HGRYHUQRQVDIHW\\UHODWHGVLJQDOV6XEVHFWLRQ
(TXLSPHQW4XDOLILFDWLRQ (6)$6&ULWHULRQ+/-7KHHIIHFWVRIHOHFWURPDJQHWLFLQWHUIHUHQFHUDGLRIUHTXHQF\\
LQWHUIHUHQFH(0,5),DQGSRZHUVXUJHVVXFKDVKLJKHQHUJ\\IDXOWVDQGOLJKWQLQJRQWKH
(6)$6LQFOXGLQJILHOGSURJUDPPDEOHJDWHDUUD\\)3*$EDVHGGLJLWDOSRUWLRQVVKDOOEH
DGHTXDWHO\\DGGUHVVHG
(6)$6UDFNPRXQWHGHTXLSPHQWLVLQVWDOOHGLQDPLOGRSHUDWLQJHQYLURQPHQWDQGLVGHVLJQHGWR
PHHWWKHHQYLURQPHQWDOFRQGLWLRQVGHVFULEHGLQ6XEVHFWLRQ 5DFNPRXQWHG(6)$6
HTXLSPHQWLVWHVWHGWRDSSURSULDWHVWDQGDUGVWRVKRZWKDWWKHHIIHFWVRI(0,5),DQGSRZHU
VXUJHVDUHDGHTXDWHO\\DGGUHVVHG7KLVWHVWLQJLQFOXGHVHPLVVLRQVWHVWLQJVXVFHSWLELOLW\\WHVWLQJ
DQGVXUJHZLWKVWDQGWHVWLQJ$SSURSULDWHJURXQGLQJRIWKH(6)$6LVSHUIRUPHGLQDFFRUGDQFH
ZLWK6HFWLRQRI,(((6WDQGDUG,(((E
6XUYHLOODQFH (6)$6&ULWHULRQ+/-(TXLSPHQWLQWKH(6)$6IURPWKHLQSXWFLUFXLWU\\WRRXWSXWDFWXDWLRQ
FLUFXLWU\\VKDOOEHGHVLJQHGWRDOORZWHVWLQJFDOLEUDWLRQDQGLQVSHFWLRQWRHQVXUHRSHUDELOLW\\,I
WHVWLQJLVUHTXLUHGRUFDQEHSHUIRUPHGDVDQRSWLRQGXULQJRSHUDWLRQWKH(6)$6VKDOOUHWDLQ
WKHFDSDELOLW\\WRDFFRPSOLVKLWVVDIHW\\IXQFWLRQZKLOHXQGHUWHVW
7KH(6)$6GHVLJQVXSSRUWVWHVWLQJPDLQWHQDQFHDQGFDOLEUDWLRQWRHQVXUHRSHUDELOLW\\DV
GHVFULEHGLQ6XEVHFWLRQV DQG6XUYHLOODQFHWHVWLQJSHUIRUPHGXVLQJWKH
PDLQWHQDQFHE\\SDVVFDSDELOLW\\GXULQJRSHUDWLRQLVFRQWUROOHGLQDFFRUGDQFHZLWKWKHWHFKQLFDO
VSHFLILFDWLRQVWRHQVXUHWKDWWKH(6)$6LVFDSDEOHRISHUIRUPLQJLWVVDIHW\\IXQFWLRQVZKHQ
UHTXLUHG6XEVHFWLRQ 6HOIWHVWLQJIHDWXUHVSURYLGHIRUPRQLWRULQJDVGHVFULEHGLQ
6XEVHFWLRQ WRSURYLGHLQGLFDWLRQWRWKHRSHUDWRULIFRQGLWLRQVH[LVWWKDWFRXOGFKDOOHQJH
RSHUDELOLW\\RIWKHHTXLSPHQW
(6)$6&ULWHULRQ+/-7HVWLQJFDOLEUDWLRQDQGLQVSHFWLRQVRIWKH(6)$6VKDOOEHVXIILFLHQWWR
VKRZWKDWRQFHSHUIRUPHGWKH\\FRQILUPWKDWVXUYHLOODQFHWHVWDQGVHOIWHVWIHDWXUHVDGGUHVV
IDLOXUHGHWHFWLRQVHOIWHVWIHDWXUHVDQGDFWLRQVWDNHQXSRQIDLOXUHGHWHFWLRQ
7KH(6)$6GHVLJQVXSSRUWVWHVWLQJPDLQWHQDQFHDQGFDOLEUDWLRQDVGHVFULEHGLQ
6XEVHFWLRQV DQG(QGWRHQGWHVWLQJRIWKHHQWLUH(6)$6SODWIRUPFDQEH
SHUIRUPHGWKURXJKRYHUODSWHVWLQJ(6)$6FRPSRQHQWVKDYHVHOIWHVWLQJFDSDELOLWLHVH[FHSWWKH
GLVFUHWH$3/RIWKH(,0SRZHUVXSSOLHVDQGKDUGZLUHGFRPPXQLFDWLRQVEHWZHHQWKH(6)$6
DQG7536YLDWKHLUUHVSHFWLYH6%90VZKLFKLVDUHIXQFWLRQDOO\\WHVWHG7KH(6)$6FRQWLQXRXVO\\
SURYLGHVUHGXQGDQWLQGLFDWLRQRIVHOIWHVWLQJUHVXOWVWRWKH3,&6WRLQGLFDWHWRRSHUDWRUVWKDWWKH
(6)$6LVRSHUDWLQJFRUUHFWO\\IROORZLQJWHVWLQJFDOLEUDWLRQRULQVSHFWLRQV
(6)$6&ULWHULRQ+/-7KHGHVLJQRIWKH(6)$6DQGWKHMXVWLILFDWLRQIRUWHVWLQWHUYDOVVKDOOEH
FRQVLVWHQWZLWKWKHVXUYHLOODQFHWHVWLQJLQWHUYDOVDVSDUWRIWKHIDFLOLW\\WHFKQLFDOVSHFLILFDWLRQV
(QJLQHHUHG6DIHW\\)HDWXUHV
&KDSWHU+/-,QVWUXPHQWDWLRQDQG&RQWURO6\\VWHPV
$FWXDWLRQ6\\VWHP 6+,1(0HGLFDO7HFKQRORJLHV
5HY
- LWKDQ6)0¶V226VZLWFKLQWKH226SRVLWLRQDQGWKHDVVRFLDWHGWULSE\\SDVVVZLWFKLQHLWKHU
WKHWULSRUE\\SDVVSRVLWLRQWKHLQSXWFKDQQHOVDVVRFLDWHGZLWKWKH6)0DUHLQRSHUDEOH
7HVWLQJ&DSDELOLW\\
7HVWLQJRIWKH(6)$6FRQVLVWVRIWKHLQVHUYLFHVHOIWHVWLQJFDSDELOLWLHVRIWKH+,36SODWIRUPDQG
SHULRGLFVXUYHLOODQFHWHVWLQJ
(QGWRHQGWHVWLQJRIWKHHQWLUH+,36SODWIRUPFDQEHSHUIRUPHGWKURXJKRYHUODSWHVWLQJ
,QGLYLGXDOVHOIWHVWVLQWKHYDULRXVFRPSRQHQWVRIWKH(6)$6HQVXUHWKDWWKHHQWLUHFRPSRQHQWLV
IXQFWLRQLQJFRUUHFWO\\6HOIWHVWIHDWXUHVDUHSURYLGHGIRUFRPSRQHQWVWKDWGRQRWKDYHVHWSRLQWVRU
WXQDEOHSDUDPHWHUV(6)$6FRPSRQHQWVH[FHSWWKHGLVFUHWH$3/RIWKH(,0KDYHVHOIWHVWLQJ
FDSDELOLWLHVWKDWHQVXUHWKHLQIRUPDWLRQSDVVHGRQWRWKHIROORZLQJVWHSLQWKHVLJQDOSDWKLV
FRUUHFW6HOIWHVWLQJLVXVHGWRGHPRQVWUDWHRSHUDELOLW\\RIFRPSRQHQWVIURPWKHVHQVRULQSXWWR
WKHRXWSXWVZLWFKLQJORJLFH[FHSWIRUWKHGLVFUHWHORJLFRIWKH$3/SRZHUVXSSOLHVDQG
KDUGZLUHGFRPPXQLFDWLRQVEHWZHHQWKH7536DQG(6)$6YLDWKHLUUHVSHFWLYH6%90V
7KHGLVFUHWHORJLFRIWKH$3/RIWKH(,0GRHVQRWKDYHVHOIWHVWFDSDELOLW\\EXWLVLQVWHDG
IXQFWLRQDOO\\WHVWHG7KLVIXQFWLRQDOWHVWLQJFRQVLVWVRISHULRGLFVLPXODWHGDXWRPDWLFDQGPDQXDO
DFWXDWLRQVWRYHULI\\WKHIXQFWLRQDOLW\\RIWKH$3/DQGWKHPDQXDODFWXDWLRQSXVKEXWWRQV7KH$3/
WHVWYHULILHVWKHRSHUDELOLW\\RIWKHGLVFUHWHSULRULW\\ORJLFFLUFXLWVRIWKH(6)$67KHVXUYHLOODQFH
IUHTXHQF\\RIWKH$3/WHVWLVDFFHSWDEOHEDVHGRQWKHEXLOWLQUHGXQGDQF\\DQGQRWLILFDWLRQRI
IDLOXUHVZLWKLQWKH(6)$6
7KHRSHUDELOLW\\RIWKHSRZHUVXSSOLHVZLWKLQWKH(6)$6FDELQHWVLVGHPRQVWUDWHGE\\FKHFNLQJWKH
YROWDJHVRIWKHSRZHUVXSSOLHVDWDIUHTXHQF\\FRQVLVWHQWZLWKWKHJXLGDQFHSURYLGHGLQ$PHULFDQ
1DWLRQDO6WDQGDUGV,QVWLWXWH$PHULFDQ1XFOHDU6RFLHW\\$16,$167KH
'HYHORSPHQWRI7HFKQLFDO6SHFLILFDWLRQVIRU5HVHDUFK5HDFWRUV$16,$16
7KHRSHUDELOLW\\RIKDUGZLUHGFRPPXQLFDWLRQVEHWZHHQWKH7536DQG(6)$6YLDWKHLUUHVSHFWLYH
6%90VLVGHPRQVWUDWHGYLDIXQFWLRQDOWHVWLQJDWDIUHTXHQF\\FRQVLVWHQWZLWKWKDWRIWKHLQSXW
GHYLFHVGHVFULEHGEHORZ
7HVWLQJRILQSXWGHYLFHVFRQVLVWVRIFKDQQHOFKHFNVFKDQQHOWHVWVDQGFKDQQHOFDOLEUDWLRQV
&KDQQHOFKHFNVDUHSHUIRUPHGZKLOHWKHFKDQQHOLVLQVHUYLFH&KDQQHOWHVWVDQGFKDQQHO
FDOLEUDWLRQVPD\\EHSHUIRUPHGZKLOHWKHDVVRFLDWHGHTXLSPHQWLVLQDFRQGLWLRQZKHUHWKH
FKDQQHOLVUHTXLUHGWREHRSHUDEOHLHLQVHUYLFHE\\SODFLQJWKHDVVRFLDWHG6)0LQ
PDLQWHQDQFHE\\SDVV6XEVHFWLRQ &KDQQHOWHVWVDQGFKDQQHOFDOLEUDWLRQVPD\\DOVREH
SHUIRUPHGZKHQWKHFKDQQHOLVQRWUHTXLUHGWREHRSHUDEOH7KHFKDQQHOFKHFNVFKDQQHOWHVWV
DQGFKDQQHOFDOLEUDWLRQVGHPRQVWUDWHRSHUDELOLW\\RIWKHFKDQQHOIURPWKHILHOGLQVWUXPHQWWKURXJK
WKH6)0HQGLQJDWWKHLQSXWWRWKH6%90RU6%0&KDQQHOFKHFNVFKDQQHOWHVWVDQGFKDQQHO
FDOLEUDWLRQVDUHSHUIRUPHGDWIUHTXHQFLHVFRQVLVWHQWZLWKWKHJXLGDQFHSURYLGHGLQ
$16,$16 $16,$16
7HFKQLFDO6SHFLILFDWLRQVDQG6XUYHLOODQFH
/LPLWLQJFRQGLWLRQVIRURSHUDWLRQDQGVXUYHLOODQFHUHTXLUHPHQWVDUHHVWDEOLVKHGIRU(6)$6ORJLF
YRWLQJDQGDFWXDWLRQGLYLVLRQVDQGLQVWUXPHQWDWLRQPRQLWRUHGE\\(6)$6DVLQSXWWRVDIHW\\
DFWXDWLRQV/LPLWLQJFRQGLWLRQVIRURSHUDWLRQDUHHVWDEOLVKHGIRUFRPSRQHQWVRIWKHVDIHW\\UHODWHG
, &V\\VWHPVWKDWSHUIRUPVDIHW\\IXQFWLRQVWRHQVXUHWKDWWKHV\\VWHPZLOOUHPDLQDYDLODEOHWR
Chapter 7 - Instrumentation and Control Systems References SHINE Medical Technologies 7.9-1 Rev. 3
7.9 REFERENCES
ANSI, 1999. Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities, ANSI N13.1-1999, American National Standards Institute, 1999.
ANSI/ANS, 1995. Quality Assurance Program Requirements for Research Reactors, ANSI/ANS 15.8-1995 (R2013), American National Standards Institute/American Nuclear Society, 1995.
ANSI/ANS, 2007. The Development of Technical Specifications for Research Reactors, ANSI/ANS-15.1-2007, American National Standards Institute/American Nuclear Society, 2007.
IEEE, 2000. IEEE Standard Application of Single-Failure Criterion to Nuclear Power Generating Station Safety Systems, IEEE 379-2000, Institute of Electrical and Electronics Engineers, 2000.
IEEE, 2003a. IEEE Standard Criteria for Digital Computers in Safety Systems of Nuclear Power Generating Stations, IEEE 7-4.3.2-2003, Institute of Electrical and Electronics Engineers, 2003.
IEEE, 2003b. IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations, IEEE 323-2003, Institute of Electrical and Electronics Engineers, 2003.
IEEE, 2004a. IEEE Standard for Software Verification and Validation, IEEE 1012-2004, Institute of Electrical and Electronics Engineers, 2004.
IEEE, 2004b. IEEE Guide for Instrumentation and Control Equipment Grounding in Generating Stations, IEEE 1050-2004, Institute of Electrical and Electronics Engineers, 2004.
IEEE, 2008. IEEE Standard Criteria for Independence of Class 1E Equipment and Circuits, IEEE 384-2008, Institute of Electrical and Electronics Engineers, 2008.
IEEE, 2013. IEEE Standard for Seismic Qualification of Equipment for Nuclear Power Generating Stations, IEEE 344-2013, Institute of Electrical and Electronics Engineers, 2013.
NuScale, 2017. NuScale Power, LLC Submittal of the Approved Version of NuScale Topical Report TR-1015-18653, Design of the Highly Integrated Protection System Platform, Revision 2 (CAC No. RQ6005), NuScale Power, LLC, September 13, 2017 (ML17256A892).
USNRC, 1994. Method for Performing Diversity and Defense-in-Depth Analyses of the Reactor Protection Systems, NUREG/CR-6303, U.S Nuclear Regulatory Commission, December 1994.
USNRC, 2010. Quality Assurance Program Requirements for Research and Test Reactors, Regulatory Guide 2.5, Revision 1, U.S. Nuclear Regulatory Commission, June 2010.
USNRC, 2017. Safety Evaluation by the Office of New Reactors, Licensing Topical Report (TR) 1015-18653-P (Revision 2), Design of the Highly Integrated Protection System Platform, NuScale Power, LLC, U.S. Nuclear Regulatory Commission, May 2017.
Page 1 of 22 ENCLOSURE 2 SHINE TECHNOLOGIES, LLC SHINE TECHNOLOGIES, LLC APPLICATION FOR AN OPERATING LICENSE SUPPLEMENT NO. 18 AND RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION The U.S. Nuclear Regulatory Commission (NRC) staff determined that additional information was required (Reference 1) to enable the continued review of the SHINE Technologies, LLC (SHINE) operating license application (Reference 2). The following information is provided by SHINE in response to the NRC staffs request.
Chapter 7 - Instrumentation and Control Systems RAI 7-27 Note 2 of SHINE FSAR Chapter 3, Design of Structures, Systems, and Components, Table 3.1-1, states that [t]he generally-applicable design criteria 1-8 from Table 3.1-3 are not specifically listed even though they are generally applicable to most SSCs. However, it is not clear to the NRC staff whether these design criteria are applicable to each radiation monitoring system (i.e., parts of ESFAS, TRPS; and TPS, RAMS, CAMS, and SRMS).
Confirm whether SHINE Design Criteria 1 - 8 are applicable to each radiation monitoring system. Update the SHINE FSAR to describe the relation of the radiation monitoring systems design bases to each applicable SHINE Design Criteria 1-8.
This information is necessary for the NRC staff to understand the relation of the design bases to the principal design criteria of the facility, as required by 10 CFR 50.34.
SHINE Response SHINE Design Criteria 1, 2, and 4 are applicable to the safety-related process radiation monitors described in Subsection 7.7.1 of the FSAR. SHINE does not rely on these radiation monitors to satisfy SHINE Design Criteria 3 and 5 through 8.
SHINE Design Criteria 1 through 8 are not applicable to the nonsafety-related process radiation monitors described in Subsection 7.7.2 of the FSAR, since these radiation monitors are not used to control personnel or environmental radiological exposures.
SHINE Design Criteria 1 through 8 are not applicable to the radiation area monitoring system (RAMS), the continuous air monitoring system (CAMS), and the stack release monitoring system (SRMS) described in Subsections 7.7.3, 7.7.4 and 7.7.5 of the FSAR, respectively.
Page 2 of 22 SHINE has revised Subsection 7.7.1.2 of the FSAR to describe the relationship of the safety-related process radiation monitor design basis to SHINE Design Criteria 1, 2, and 4. A mark-up of these changes is provided as Attachment 1.
RAI 7-28 NUREG-1537, Part 2, Section 7.7, Radiation Monitoring Systems, states, in part, that [t]he applicant should address all equipment, devices, and systems used for monitoring or measuring radiation intensities or radioactivity [t]his section should detail the operating principles, designs, and functional performance of the I&C aspects of the system [RMS]. Although there may be different types of radiation monitoring systems (as is the case in the SHINE application),
the guidance in NUREG-1537, Part 2, Section 7.7, does not provide specific guidance for different types of radiation monitoring systems, rather the guidance in Section 7.7 is understood to be applicable to all radiation monitoring systems.
The acceptance criteria of NUREG-1537, Part 2, Section 7.7 states the following:
The instrument ranges should be sufficient to cover the expected range of variation of the monitored variable under the full range of normal operation and if assumed in the SAR analysis, accident conditions.
The sensitivity of each system should be commensurate with the precision and accuracy to which knowledge of the variable is required by analysis or design basis.
In addition, NUREG-1537, Part 2, Section 7.6, Control Console and Display Instruments, provides guidance for evaluating the control console and display instruments to determine that they include signals from instrument systems monitoring activities, and other system process variables analytically or digitally processed outputs based on monitored variables. The acceptance criteria in NUREG-1537, Part 2, Section 7.3, Reactor Control Systems, states the following:
The system should give reliable information about the status and magnitude of process variables necessary for the full range of normal reactor operation.
The radiation monitoring systems described in FSAR Section 7.7 should conform to the acceptance criteria and guidelines so that the controlled variables can be maintained within prescribed ranges for normal operations, anticipated transients, and accident conditions, including the effects of maloperation or failure of the system. Accordingly, the SHINE FSAR should describe the design bases, acceptance criteria, and guidelines used for design of the RMS, as well as analysis of the adequacy of the designs to perform the functions necessary to monitor and control the SHINE facility.
(a) Monitored and displayed variables NUREG-1537, Part 2, Section 7.7, describes that the systems should be designed to interface with either analog or digital computerized reactor control system or reactor protection system if applicable.
SHINE FSAR Chapter 3, Table 3.1-3, SHINE Design Criteria, states, in part, the SHINE design criteria as follows:
Page 3 of 22 SHINE Design Criterion 13, Instrumentation and controls, instrumentation is provided to monitor variables and systems over the expected range of variation of the monitored variable during normal and transient operation. Also, this criterion requires that the information provided be sufficient to verify that individual safety limits are protected by independent channels. (Note: per FSAR Chapter 3 Tables 3.1-1 and 3.1-2 SHINE Design Criteria 13 applies to TRPS, ESFAS, CAMS, RAMS, and SRMS).
SHINE Design Criterion 38, Monitoring radioactivity releases, means are provided for monitoring the primary confinement boundary, hot cell, and glovebox atmospheres to detect potential leakage of gaseous or other airborne radioactive material. Potential effluent discharge paths and the plant environs are monitored for radioactivity that may be released from normal operations, including anticipated transients, and from postulated accidents.
(Note: per FSAR Chapter 3 Table 3.1-2 SHINE Design Criteria 38 applies to TRPS, ESFAS, TPS, CAMS, RAMS, and SRMS).
SHINE FSAR Table 7.7-1, Safety-Related Process Radiation Monitors, identifies the safety-related process radiation monitors, monitored locations, total available channels, minimum required channels, and operability requirements. In addition, Tables 7.4-1, TRPS Monitored Variables, and 7.5-1, ESFAS Monitored Variables, identify the radiation variables monitored by the TRPS and ESFAS, respectively. These tables identify range, accuracy, and response time. Further, Section 7.7.1.3.4, Independence, describes that safety-related process radiation monitors provide analog communication to the ESFAS and TRPS controls.
This section also describes that these radiation monitoring data is provided to non-safety systems through one-way isolated outputs.
SHINE FSAR Section 7.7.1.2.1, Instrument and Controls, states, in part, the Safety-related radiation monitoring channels produce a full-scale reading when subject to radiation fields higher than the full-scale reading; however, they are expected to remain on-scale during accident conditions." Therefore, the NRC staff seeks clarification on the response of the radiation monitoring channels when subject to radiation fields that are higher than the full-scale reading.
- 1. Identify the means (e.g., radiation monitor and associated control room indications) provided for monitoring each: (1) the primary confinement boundary, (2) hot cell, and (3) glovebox atmospheres (to detect potential leakage of gaseous or other airborne radioactive material).
Identify the means (e.g., radiation monitor and associated control room indications) provided for monitoring the potential effluent discharge paths and the plant environs for radioactivity that may be released from normal operations, including anticipated transients, and from postulated accidents.
- 2. Clarify the statement in Section 7.7.1.2.1 regarding response of the radiation monitoring channels is compatible with the digital equipment in the HIPS equipment (i.e., Is the associated HIPS value full-scale and valid or invalid?) when subjected to radiation fields higher than the full-scale reading.
Page 4 of 22 The information requested is necessary to support the following finding in Section 7.7 of NUREG-1537, Part 2:
The systems should be designed to interface with either analog or digital computerized RCS [reactor control system] or RPS [reactor protection system] if applicable.
(b) Tritium measurement and monitored variable SHINE Design Criterion 38, Monitoring radioactivity releases, states that:
Means are provided for monitoring the primary confinement boundary, hot cell, and glovebox atmospheres to detect potential leakage of gaseous or other airborne radioactive material. Potential effluent discharge paths and the plant environs are monitored for radioactivity that may be released from normal operations, including anticipated transients, and from postulated accidents.
SHINE FSAR Section 7.7.1.4.1, Functionality, describes that the TPS process monitors the tritium concentration within the TPS gloveboxes. SHINE FSAR Table 7.7-1, includes tritium as a monitored material. Based on this information, it is not clear to the NRC staff what instruments or monitors will be used for measuring tritium concentrations within the TPS gloveboxes. Also, it is not clear to the NRC staff whether tritium concentrations within the TPS gloveboxes will be presented to the operator in the control console.
SHINE FSAR Section 7.7.4.1, System Description, describes that CAMS would be used to measure tritium activity to alert personnel when airborne contamination is above preset limits.
Also, SHINE FSAR Section 7.7.5.1, System Description, describes that the effluent monitoring system includes capabilities to collect and analyze tritium. Based on this information, it is not clear to the NRC staff whether tritium measurements by TPS process monitors, CAMS, and effluent monitors would be transmitted to the Process Integrated Control System. Therefore, it is not clear to the NRC staff what information will be presented to the operator in the control room to monitor the primary confinement boundary, hot cell, and glovebox atmospheres to detect potential leakage of gaseous or other airborne radioactive material.
In RAI 7-20 (a)(2) (ADAMS Accession No. ML21253A234), the NRC staff also requested identification of variables transmitted to the ESFAS, which may overlap with the information being requested in this RAI.
Update the SHINE FSAR to describe the radiation instrument and controls in place to measure tritium concentrations, as well as the information provided to operators in the control room related to tritium concentration for performing manual protective actions in accordance with SHINE Design Criterion 38.
(c) Setpoint Methodology and Calculations NUREG-1537, Part 2, Section 7.7, describes, in part, that the instrument ranges should be sufficient to cover the expected range of variation of the monitored variable under the full range of normal operation and if assumed in the safety analysis report analysis, accident conditions.
This section also describes that the sensitivity of each system should be commensurate with the precision and accuracy to which knowledge of the variable is required by analysis or design basis.
Page 5 of 22 Subparagraph (c)(1)(ii)(A) of 10 CFR 50.36, Technical specifications, describes that limiting safety system settings (LSSS) are settings for automatic protective devices related to those variables having significant safety functions. This requires that a LSSS is specified for a variable on which a safety limit has been placed, the setting must be chosen so that automatic protective action will correct the abnormal situation before a safety limit is exceeded.
SHINE FSAR Section 7.7.1.2.1 states, in part, that Setpoints are selected based on analytical limits and calculated to account for known uncertainties in accordance with the setpoint determination methodology. In addition, SHINE FSAR Section 7.7.1.4.3, Setpoints, Calibration and Surveillance, states, in part, that Setpoints for safety-related process radiation monitors are selected based on analytical limits and calculated to account for known uncertainties in accordance with the setpoint determination methodology.
SHINE technical specification (TS) Table 3.7.1-a, Safety-Related Radiation Monitoring Instruments, identifies the setpoints for the safety-related radiation monitors. However, the SHINE FSAR does not describe the methodology used to determine these setpoints. The SHINE FSAR Section 7.2.1 states that a setpoint methodology is used for establishing and calibrating setpoints for safety-related I&C functions. This FSAR section generally describes SHINEs setpoint methodology but lacks specificity in calculating setpoints for various types of instruments used in varying applications. The setpoints for protective function should be based on a documented analysis methodology that identifies assumptions and accounts for instrument uncertainties, such as environmental allowances and measurement computational errors associated with each element of the instrument channel.
- 1. Identify all automatic protective actions that are initiated based on a (radiation monitor related) setpoint other than those of TRPS and ESFAS (which are addressed by the response to RAI 7-20). The following additional questions apply to the non-TRPS/ESFAS setpoints.
- 2. Revise the SHINE FSAR to describe the setpoint methodology used to establish the setpoints or LSSS from the analytical limits for the variables monitored. The description of the setpoint methodology should include parameters typically consider instrument precision, sensitivity, accuracy, loop uncertainties, and computational errors.
- 3. Provide a definition of the equipment accuracy identified in SHINE FSAR Table 7.7-1 and that used in the setpoint methodology.
The information requested is necessary to support the following finding in Section 7.4 of NUREG-1537, Part 2:
The protection channels and protective responses are sufficient to ensure that no safety limit, limiting safety system setting, or related limiting condition of operation discussed and analyzed in the SHINE FSAR will be exceeded. (Also, see RAI 7-20(f) in which the NRC staff requested information on the setpoint methodology used to establish the setpoints or LSSS from the analytical limits for the variables monitored by the TRPS and ESFAS.).
Page 6 of 22 SHINE Response (a) Monitored and displayed variables
- 1. The safety-related process radiation monitors that monitor the primary confinement boundary are described in Table 7.7-1 of the FSAR as units 17 through 24.
The safety-related process radiation monitors that monitor the hot cell (i.e., supercell) are described in Table 7.7-1 of the FSAR as units 1 through 10 and 25 through 27.
The safety-related process radiation monitors that monitor the tritium purification system (TPS) glovebox atmospheres are described in the SHINE Response to Part (b) of RAI 7-28.
The safety-related process radiation monitors that monitor the potential effluent discharge paths and the plant environs are described in Table 7.7-1 of the FSAR as units 11, 12, and 16.
The safety-related process radiation monitors described in Table 7.7-1 of the FSAR provide inputs to the target solution vessel (TSV) reactivity protection system (TRPS) or engineered safety features actuation system (ESFAS). As described in the SHINE Response to Part (a)(1) of RAI 7-20 (Reference 3), variables monitored by the TRPS and ESFAS are provided to operators in the facility control room (FCR) to monitor the operation and status of the irradiation facility (IF) and the radioisotope production facility (RPF).
The RAMS, CAMS, and SRMS provide defense-in-depth functions and indications as described in the SHINE Response to Part (c) of RAI 7-30.
- 2. The safety-related process radiation monitors are designed to function during normal operation, anticipated transients, and design basis accidents to a level required to detect accident conditions and provide safety-related inputs to the TRPS and ESFAS to initiate protective actions. If the measured radiation field goes above the full-scale, the analog output from the safety-related process radiation monitor will be equivalent to the full-scale reading. The TRPS or ESFAS will process this signal as a valid, full-scale value.
SHINE has revised Subsections 7.7.1.2.1 and 7.7.1.3.1 of the FSAR to clarify the descriptions of how the safety-related process radiation monitors provide indication when subjected to radiation fields higher than the full-scale reading. A markup of the FSAR incorporating these changes is provided as Attachment 1.
(b) Tritium measurement and monitored variable The safety-related process radiation monitors which measure tritium concentration within the TPS gloveboxes are described in Table 7.7-1 of the FSAR as units 13, 14, and 15 for TPS confinement A, B, and C, respectively. Additionally, unit 16 of Table 7.7-1 of the FSAR measures tritium concentration in TPS exhaust. These tritium monitors provide input to ESFAS.
As described in the SHINE Response to Part (a)(1) of RAI 7-20 (Reference 3), variables monitored by the ESFAS are provided to operators in the FCR to monitor the operation and status of the IF and the RPF.
In addition to the above-identified safety-related process radiation monitors which measure tritium concentration, Tritium Monitor 12 and Tritium Monitor 13 of the CAMS, as described in
Page 7 of 22 Table 7.7-3 of the FSAR, measure tritium concentration. Information from the nonsafety-related CAMS is provided to operators in the facility control room via the process integrated control system (PICS), as described in the SHINE Response to RAI 7-30(c).
SHINE Design Criterion 38 does not require the performance of manual protective actions to be satisfied. As described in the SHINE Response to Part (a)(1) of RAI 7-20, manual protective actions are not required for the safe operation of the SHINE facility.
As the above information is already provided in the SHINE licensing basis, no additional need to modify the FSAR was identified.
(c) Setpoint Methodology and Calculations
- 1. There are no automatic protective actions that are initiated based on a radiation monitor related setpoint other than those of the TRPS and the ESFAS.
The safety-related process radiation monitors identified in Table 7.7-1 of the FSAR each provide an input to the TRPS or the ESFAS based upon the radiation readings detected.
There are no setpoints in the safety-related process radiation monitors themselves, and no logic is performed within a monitor to compare a safety-related process radiation monitor reading with a setpoint. Setpoints associated with the safety-related process radiation monitors are contained in the TRPS and the ESFAS. The TRPS and the ESFAS receive inputs from the safety-related process radiation monitors, compare these inputs to the associated setpoints, and generate an actuation signal as necessary. Inputs from safety-related process radiation monitors to the TRPS and ESFAS and the logic used to generate an actuation signal are provided in Figure 7.4-1 and Figure 7.5-1 of the FSAR, respectively.
The SHINE Response to Part (f) of RAI 7-20 (Reference 3) provides a description of the methodology used to establish setpoints for the TRPS and ESFAS.
- 2. N/A - There are no automatic protective actions that are initiated based on a radiation monitor related setpoint other than those of the TRPS and the ESFAS.
- 3. N/A - There are no automatic protective actions that are initiated based on a radiation monitor related setpoint other than those of the TRPS and the ESFAS.
RAI 7-29 NUREG-1537, Part 2, Section 7.7 describes, in part, that information should be provided for the NRC staff to evaluate the signal processing equipment, computer hardware and software that controls sampling, detection, signal processing and logic, power supplies, and actuation systems that accomplish a function for the system.
SHINE FSAR Section 7.7.1.1, System Description, states, in part:
Safety-related process radiation monitors provide input to the safety-related ESFAS or TRPS control systems. These components monitor for either fission products (via beta detection) or tritium. Beta detection radiation monitors are part of the ESFAS or TRPS. The type of safety-related process radiation monitor (fission product or tritium) is selected based on the location and identity of the radioactive material present. The ESFAS and TRPS
Page 8 of 22 process radiation monitors (beta detection) are intended to detect abnormal situations within the facility ventilation systems and provide actuation signals to the ESFAS controls.
Safety-related tritium monitors are part of the TPS. The TPS monitors are installed within various portions of the TPS to detect potential tritium releases, provide actuation signals to the ESFAS controls, and provide interlock inputs to the TRPS controls.
SHINE FSAR Sections 7.7.1.3, Design Bases, and 7.7.1.4, Operation and Performance, describe design bases and operation and performance of the safety-related process radiation monitors. Based on the information in the SHINE FSAR, the NRC staff does not have a clear description of the radiation monitoring equipment to be installed in the facility (i.e., technology included).
Revise the FSAR to describe whether the safety-related process radiation monitors use analog or digital technology. If the safety-related process radiation monitors use digital technology (per NUREG-1537, Part 2, Section 7.7) describe how the hardware and software for these radiation monitors meet the guidelines of Institute of Electrical and Electronics Engineers (IEEE)
Std. 7-4.3.2-1993, IEEE Standard Criteria for Digital Computers in Safety Systems of Nuclear Power Generating Stations, and Regulatory Guide (RG) 1.152, Revision 1, Criteria for Digital Computers In Safety Systems of Nuclear Power Plants, and software meets the guidelines of American National Standards Institute/American Nuclear Society (ANSI/ANS)-10.4-1987, Guidelines for the Verification and Validation of Scientific and Engineering Computer Programs for the Nuclear Industry.
The information requested is necessary to support the following finding in Section 7.7 of NUREG-1537, Part 2:
The designs and operating principles of the instrumentation and control of the radiation detectors and monitors have been described, and have been shown to be applicable to the anticipated sources of radiation.
SHINE Response Safety-related process radiation monitors that monitor for tritium, described as units 13, 14, 15, and 16 of Table 7.7-1 of the FSAR, use solely analog technology. Safety-related process radiation monitors that monitor for fission products, described as units 1 through 12 and 17 through 27 of Table 7.7-1 of the FSAR, use digital detectors to provide an analog signal to the TRPS or ESFAS. The processing of these analog signals by the TRPS and the ESFAS is described in the SHINE Response to Part (c) of RAI 7-28 and the SHINE Response to RAI 7-31.
In lieu of complying with the nuclear power plant-specific guidance of Regulatory Guide 1.152, Criteria for the Use of Computers in Safety Systems of Nuclear Power Plants, SHINE complies with applicable portions of Institute of Electrical and Electronics Engineers (IEEE) 7-4.3.2-2003, Standard Criteria for Digital Computers in Safety Systems of Nuclear Power Generating Stations (Reference 4). The safety-related process radiation monitors that use digital detectors comply with Sections 5.3.1, 5.3.2, 5.3.4, 5.3.5, 5.3.6, 5.5.1, 5.5.2, and 5.5.3 of IEEE 7 4.3.2 2003. SHINE has procured the safety-related process radiation monitors from a quality level (QL)-1 vendor that documents compliance with these applicable sections of IEEE 7 4.3.2-2003.
SHINE considers the guidance contained in the above-listed sections of IEEE 7-4.3.2-2003 to be sufficient and more current than that contained in American National Standards Institute
Page 9 of 22 (ANSI)/American Nuclear Society (ANS)-10.4-1987, Guidelines for the Verification and Validation of Scientific and Engineering Computer Programs for the Nuclear Industry (Reference 5). The most recent version of this standard (i.e., ANSI/ANS-10.4-2008, Verification and Validation of Non-Safety-Related Scientific and Engineering Computer Programs for the Nuclear Industry [Reference 6]) would not be applicable to the safety-related process radiation monitors that use digital detectors.
SHINE has revised Subsection 7.7.1.1 of the FSAR to describe the use of analog and digital technology for safety-related process radiation monitors. A markup of the FSAR incorporating these changes is provided as Attachment 1.
RAI 7-30 NUREG-1537, Part 2, Section 7.7 states that, The systems and equipment should be designed for reliable operation in the environment in which they will function. This section also describes that consideration should be given to the need for single failure protection, seismic and environmental qualification protection, and diversity.
SHINE FSAR Section 7.7.1.4.2, Reliability, Adequacy, and Timeliness, describes reliability for the safety-related process radiation monitors. SHINE FSAR Section 7.7.1.3, describes the design bases for the safety-related process radiation monitors, including single failure, independence, and redundancy.
(a) Single failure SHINE FSAR Section 7.7.1.3.3, Single Failure, describes that safety-related redundant monitors are used for locations requiring radiation monitoring, and for locations where spurious actuation of the process radiation monitor could significantly impact overall facility operation, a third sensing channel was added. Adding redundant monitors increases the reliability of the system. Further, SHINE FSAR Section 7.7.1.3.5, Redundancy, describes how the system meets the single failure criterion by using redundant safety-related monitors. However, the FSAR does not describe how these monitors are assigned to each division of the ESFAS and TRPS.
- 1. Update the SHINE FSAR to demonstrate that single failures in the safety-related process radiation monitors do not result in loss of the protection or mitigation function.
- 2. Update the SHINE FSAR to identify radiation monitors that are only assigned to Division A for TRPS and ESFAS, as appropriate, as well as radiation monitors that include a third sensing division (Division C).
(b) Independence SHINE FSAR Section 7.7.1.3.4, describes independence of the safety-related process radiation monitors. This section provides information about communication, physical, and electrical independence. SHINE FSAR Section 7.7.1.3.7, Fire Protection, notes that physical separation is used to achieve separation of redundant sensors. This section also notes that wiring for redundant channels uses physical separation and isolation to provide independence for circuits.
However, the information in FSAR Sections 7.7.1.3.4 and 7.7.1.3.7 does not provide sufficient information for the NRC staff to assess how independence is implemented to prevent the failure of the safety-related process radiation monitors and provide reliable operation. The FSAR
Page 10 of 22 should describe how the safety-related process radiation monitors include electrical and communications independence both within the safety-related radiation monitoring channels and between the safety-related process radiation monitors and non-safety-related systems. For communication independence, the FSAR should demonstrate that credible failures such as a logical or software malfunction of the non-safety system would not affect the functions of the safety-related process radiation monitors.
Section 7.7.1.3.4 of the FSAR states that the safety-related process radiation monitors from separate divisions are physically separated from each other and independently powered from the associated UPSS division. However, the information provided is insufficient to evaluate how the safety-related process radiation monitors would be powered and how the system would be powered in case of a loss of power. The FSAR should describe electrical independence are used to maintain the independence of safety-related process radiation monitor circuits and equipment among redundant safety divisions or with non-safety systems so that the safety functions required during and following any analyzed accident can be accomplished.
Update the SHINE FSAR to explain how the safety-related process radiation monitors design implements communication and electrical independence to provide reliable operation.
(c) Defense-in-depth NUREG-1537, Part 1, Section 7.1.2, Design Criteria, describes in part that the SAR should discuss diversity and redundancy of ICSs, and other defense-in-depth features.
Although the SHINE FSAR does not identify any SHINE Design Criterion or criterion for defense-in-depth, SHINE FSAR Section 7.7.1.3.1, Design Bases Functions, notes that radiation monitoring systems are provided for defense-in-depth. It is not clear to the NRC staff if other (non-safety-related) monitors are installed in certain areas, and therefore provide defense-in-depth to the safety-related radiation monitoring channels. Also, SHINE FSAR Sections 7.7.3.1 and 7.7.4.1 note that the RAMS and continuous air monitoring system CAMS provide defense-in-depth to alert personnel on the need to evacuate. Based on this information, it is not clear to the NRC staff whether the RAMS and CAMS are providing defense-in-depth to the safety-related radiation monitoring channels.
Confirm if only CAMS and RAMS provide defense-in-depth to safety-related process radiation monitors and provide a list of relevant information that would be transmitted to the operators.
Specifically, the information requested in parts (a) through (c) of RAI 7-30, above, is necessary to support the following evaluation findings in Section 7.7 of NUREG-1537, Part 2:
The systems and equipment should be designed for reliable operation in the environment in which they will function.
The systems should be designed not to fail or operate in a mode that would prevent the RPS from performing its safety function, or prevent safe reactor shutdown.
Page 11 of 22 SHINE Response (a) Single failure
- 1. Safety-related process radiation monitors were considered as sensors in the single failure analysis of the TRPS and ESFAS described in the SHINE Response to RAI 7-12 (Reference 7). Single failures in safety-related process radiation monitors do not result in a loss of the protection function, as described in the SHINE Response to RAI 7-12.
Subsection 7.4.5.2.2 of the FSAR was updated as part of the SHINE Response to RAI 7-12 to enhance the description of the single failure analysis of the TRPS and ESFAS.
- 2. The assignment of safety-related process radiation monitors to each division of the TRPS and the ESFAS is shown in Figure 7.4-1 and Figure 7.5-1 of the FSAR.
There are no safety-related process radiation monitors assigned only to Division A of the TRPS or the ESFAS.
Safety-related process radiation monitors that include a third sensing division (i.e.,
Division C) are shown in Figures 7.4-1 and 7.5-1 of the FSAR as described above.
Additionally, these safety-related process radiation monitors are identified as having three total available channels in Table 7.7-1 of the FSAR.
(b) Independence The safety-related process radiation monitors are electrically separated by division, as described in Subsection 7.7.1.3.7 of the FSAR, and provide analog signals to a particular division of the TRPS or the ESFAS. As described in Subsection 7.4.5.2.1 of the FSAR, physical separation is maintained between divisions of safety-related process radiation monitors, and divisional independence is maintained from the safety-related process radiation monitor, through the TRPS and ESFAS, to the devices actuating the protective function.
The safety-related process radiation monitors are included in the safety-related instrumentation depicted in Figure 7.1-1 of the FSAR, provide analog signals directly to the TRPS and ESFAS, and do not interface electrically with any nonsafety-related system. Electrical separation is maintained between safety-related and nonsafety-related systems in accordance with Section 5.1.1.2, Table 1 of Section 5.1.3.3, and Table 2 of Section 5.1.4 of IEEE Standard 384-2008, Standard Criteria for Independence of Class 1E Equipment and Circuits (Reference 8).
Therefore, credible failures of nonsafety related systems would not affect the functions of the safety-related process radiation monitors, demonstrating communications independence.
Electrical independence is maintained in the power supplies to the safety-related process radiation monitors. Safety-related process radiation monitors associated with division A receive power from division A of the uninterruptible electrical power supply system (UPSS).
Safety-related process radiation monitors associated with Division B receive power from division B of the UPSS. Safety-related process radiation monitors associated with division C receive auctioneered power from division A and division B of the UPSS. The UPSS provides safety-related power to system loads, including the safety-related process radiation monitors, as described in Subsection 8a2.2.3 of the FSAR.
Page 12 of 22 SHINE has revised Subsection 7.7.1.3.4 and Subsection 7.7.1.3.7 of the FSAR to enhance the description of how safety-related process radiation monitors implement independence. A markup of the FSAR incorporating these changes is provided as Attachment 1.
(c) Defense-in-depth As stated in Subsection 7.7.1.3.1 of the FSAR, for defense-in-depth, the radiologically controlled area (RCA) exhaust, general area direct radiation levels, and general area airborne particulates are monitored by stack release, radiation area, and continuous area monitors, respectively. The monitors referred to in this sentence are part of the SRMS, the RAMS, and the CAMS.
Therefore, the SRMS, RAMS, and CAMS provide defense-in-depth to the safety-related process radiation monitors. Nonsafety-related process monitors described in Subsection 7.7.2 of the FSAR are not used for defense-in-depth to the safety-related radiation monitors.
Information from each RAMS monitor (radiation dose rate) is provided to the operators in the facility control room via the PICS, as described in Subsection 7.7.3 of the FSAR. Table 7.7-2 of the FSAR provides the locations of the RAMS monitors.
Information from each CAMS monitor (airborne radiation levels) is provided to operators in the facility control room via the PICS, as described in Subsection 7.7.4 of the FSAR. Table 7.7-3 of the FSAR provides the locations of the CAMS monitors.
A description of the information the SRMS provides to the operators in the facility control room is provided in the SHINE Response to RAI 7-32.
RAI 7-31 SHINE FSAR Section 7.7.1.3.4, describes that the safety-related process radiation monitors provide analog signals to the TRPS and ESFAS. Further, SHINE FSAR Section 7.7.1.4.1, describes the functionality of the safety-related process radiation monitors, which transmits signals to the TRPS to actuate safety functions and the ESFAS to provide an actuation signal when radiation levels exceed pre-determined limits. SHINE FSAR Figures 7.4-1, TRPS Logic Diagrams, and 7.5-1, ESFAS Logic Diagrams, in the SHINE FSAR show the logic diagrams for the TRPS and ESFAS, respectively. While these figures show the actuation signal, the logic to process the analog signals and generate the actuation signal is not described.
Update the SHINE FSAR to describe where the logic and processing of the radiation monitor signals are performed, as well as identify what signals are transmitted to the TRPS and ESFAS.
The information requested is necessary to support the following finding in Section 7.7 of NUREG-1537, Part 2:
The systems should be designed to interface with either analog or digital computerized RCS or RPS if applicable.
SHINE Response The safety-related process radiation monitors identified in Table 7.7-1 of the FSAR provide analog signals indicating radiation levels to the TRPS and the ESFAS. There are no setpoints in the safety-related process radiation monitors themselves, and no logic is performed within a monitor to compare a safety-related process radiation monitor reading with a setpoint. Setpoints
Page 13 of 22 associated with the safety-related process radiation monitors are contained in the TRPS and the ESFAS. The TRPS and the ESFAS receive inputs from the safety-related process radiation monitors, compare these inputs to the associated setpoints, and generate an actuation signal as necessary. Inputs from safety-related process radiation monitors to the TRPS and the ESFAS and the logic used to generate an actuation signal are provided in Figures 7.4-1 and 7.5-1 of the FSAR. This logic scheme is further described in the SHINE Response to RAI 7-21 (Reference 3).
SHINE has revised Subsection 7.7.1 of the FSAR to clarify the descriptions of the signals transmitted from the safety-related process radiation monitors to the TRPS and ESFAS. A markup of the FSAR incorporating these changes is provided as Attachment 1.
RAI 7-32 The SHINE facility includes a SRMS to monitor effluents in the facility. This system, as described in SHINE FSAR Section 7.7.5, Effluent Monitoring, includes the carbon delay bed effluent monitor (CDBEM), which monitors for noble gases at the exhaust of the process vessel vent system (PVVS) carbon delay beds to provide information about the health of the PVVS carbon delay beds and to provide the ability to monitor the safety-related exhaust point effluent release pathway when it is in use. SHINE FSAR Section 7.7.5.2.1, Applicable Design Criteria, states, in part, that The SRMS units are designed to operate under normal facility conditions and to detect radiation that may be indicative of anticipated transients or design basis accidents. However, the SHINE FSAR does not clearly describe what information will be presented to the operator for normal operation of the facility and if any manual protective actions are required based on detected radiation levels by the SRMS units that may be indicative of anticipated transients or design basis accidents. Also, the SHINE FSAR refers to but does not fully describe or explain what is the safety-related exhaust point effluent release pathway and when it is used. SHINE FSAR Section 7.7.5.1, System Description, notes that the CDBEM does not perform any accident mitigation or personnel protection, and instead it is used to monitor compliance with regulatory limits.
Update the SHINE FSAR to describe information necessary for normal operation of the facility and if any manual protective actions are required based on detected radiation levels by the SRMS units that may be indicative of anticipated transients or design basis accidents.
The information requested is necessary to support the following finding in Section 7.6 of NUREG-1537, Part 2:
The outputs and display devices showing reactor nuclear status should be readily observable by the operator while positioned at the reactor control and manual protection systems.
SHINE Response The SRMS is composed of two monitoring units: the stack release monitor (SRM) and the carbon delay bed effluent monitor (CDBEM), as described in Subsection 7.7.5.1 of the FSAR.
The SRMS monitors provide defense-in-depth for the safety-related process radiation monitors, as described in the SHINE Response to Part (c) of RAI 7-30. Noble gas activity levels from SRMS monitors will be available to operators in the facility control room. There are no manual protective actions required based on detected radiation levels by the SRMS monitors.
Page 14 of 22 The safety-related exhaust point depicted in Figure 7.7-1 of the FSAR and described in Subsection 7.7.5.4 of the FSAR is associated with the carbon delay beds, which are part of the process vessel vent system (PVVS). Safety functions associated with the PVVS are described in Subsection 9b.6.1.3 of the FSAR. Safety actuations associated with monitored variables in the PVVS are described in Subsections 7.5.3.1.14, 7.5.3.1.15, 7.5.3.1.16, and 7.5.3.1.23 of the FSAR. Although the CDBEM monitors a safety-related point in the PVVS system, the CDBEM is not required to perform a safety function. The CDBEM is used to monitor the health of the carbon delay beds and provide indication of noble gas concentrations to support monitoring for regulatory compliance, as described in Subsection 7.7.5.1 of the FSAR.
SHINE has revised Subsection 7.7.5.4 of the FSAR to enhance the description of the safety-related exhaust point. A markup of the FSAR incorporating these changes is provided as.
RAI 7-33 NUREG-1537, Part 2, Section 7.7, describes, in part, that the systems should be designed not to fail or operate in a mode that would prevent the RPS from performing its safety function, or prevent safe reactor shutdown.
SHINE FSAR Section 7.7.1.3.3, describes how the safety-related process radiation monitors design addresses single failure. This section describes that no single failure of a detector, control division, or power division will prevent the safety-related system from performing its safety function. However, the SHINE FSAR does not describe assessments performed to identify the potential failures and the associated analyses that confirm these failures would not prevent the RPS from performing its safety function, or prevent safe reactor shutdown or initiate a condition not considered in the accident analyses.
- 1. Update the SHINE FSAR to include a summary description of the potential safety-related process radiation monitors failures identified and confirm that they would not affect the operation of the TRPS and ESFAS, as requested by RAI 7-12. (Note: An audit can be used to confirm the description).
- 2. Update the SHINE FSAR to include a summary description of the fail-safe state of the safety-related radiation process monitors when the system loses electrical power and when other known failures manifest. (Note: An audit can be used to confirm the description).
The information requested is necessary to support the following finding in Section 7.7 of NUREG-1537, Part 2:
The systems should be designed not to fail or operate in a mode that would prevent the RPS from performing its safety function, or prevent safe reactor shutdown.
SHINE Response
- 1. For each safety-related process radiation monitor input to the TRPS or the ESFAS, there are either two (to Divisions A and B) or three (to Divisions A, B, and C) redundant and independent radiation monitors which provide an analog input to the respective TRPS or ESFAS division. The input provided to the TRPS or ESFAS is a signal based upon the radiation levels detected. The TRPS or ESFAS compares this signal to a setpoint and
Page 15 of 22 determines if an automatic protective action is required. Automatic protective actions based on two inputs utilize one-out-of-two (1oo2) voting logic whereas those based on three inputs utilize two-out-of-three (2oo3) voting logic. The application of the voting logic takes place internal to the TRPS or ESFAS.
The safety-related process radiation monitors are considered in the single failure analysis described in the SHINE Response to RAI 7-12 (Reference 7). For functions with 1oo2 voting, the protective action is initiated if one of the two channels vote to trip. If one of the two channels fail such that it does not produce a trip, the remaining channel is capable of initiating the required protective action. For functions with 2oo3 voting, the protective action is initiated if two of the three channels vote to trip. If one of the three channels fail such that it does not produce a trip, the remaining two channels are capable of initiating the required protective action.
Potential failure types for inputs from the safety-related process radiation monitors to the TRPS and ESFAS are identified and evaluated in the failure modes and effects analysis (FMEA) described in the SHINE Response to RAI 7-12. The failure types identified for these inputs include the signal Failing Low, Failing High, Short Circuit, Open Circuit, Fail As Is, and a Loose Connection.
For the Failing Low and Failing High failure types, automatic signal limits checking in the Safety Function Module (SFM) detect the fault and generate alarm information which is provided to the PICS for alerting an operator. When this type of fault occurs, the SFM provides the fault information to its associated scheduling and bypass modules (SBM) or scheduling, bypass, and voting modules (SBVM) and the partial trip information for the failed channel is determined by the SBMs or SBVMs based on the state of the associated SFMs Trip/Bypass switch, the position of which is controlled by facility technical specifications during normal operation.
For the Short Circuit and Open Circuit failure types, the result is similar to the Failing Low/Failing High failure types in that the fault is detected by self-testing in the input submodule (ISM) on the SFM, the fault information is then provided to the associated SBMs or SBVMs, and the partial trip information for the failed channel is determined by the SBMs or SBVMs based on the state of the associated SFMs Trip/Bypass switch.
For the Fail As Is failure type, the associated division is not able to determine the need for a protective action when conditions exist. For functions with 2oo3 voting, there are two other divisions available to make a trip determination. For functions with 1oo2 voting, there is one other division available to make a trip determination.
For the Loose Connection failure type, this would have a similar result as the Failing Low, Failing High, or Open Circuit failure types.
Therefore, the FMEA shows that the failure modes applicable to the safety-related process radiation monitors do not affect the operation of the TRPS or ESFAS.
SHINE has revised Subsection 7.7.1.3.3 of the FSAR to enhance the description of single failure for the safety-related process radiation monitors. A markup of the FSAR incorporating these changes is provided as Attachment 1.
Page 16 of 22
- 2. If the safety-related process radiation detectors lose power, analog outputs to the TRPS or the ESFAS Fail Low and the partial trip information for the failed channel is determined based upon the associated SFMs out-of-service status, as described above. Any other known failures associated with the safety-related process radiation monitor coincident with loss of power to the monitor do not result in a failure different from the six failure types discussed above.
SHINE has revised Subsection 7.7.1.3.3 of the FSAR to enhance the description of a loss of power for the safety-related process radiation monitors. A markup of the FSAR incorporating these changes is provided as Attachment 1.
RAI 7-34 NUREG-1537, Part 2, Section 7.7, Radiation Monitoring Systems, describes that the systems and equipment should be designed for reliable operation in the environment in which they will function.
SHINE Design Criterion 13, Instrumentation and controls, states, in part, that instrumentation is provided to monitor variables and systems over the expected range of variation of the monitored variable during normal and transient operation.
SHINE FSAR Section 7.7.1.3.2, Operating Conditions, describes the environmental conditions for the different areas within the SHINE facility. However, this FSAR section does not include information for the NRC staff to confirm that the equipment environmental test results envelop the environmental conditions identified in FSAR Tables 7.2-2 through 7.2-5.
In addition, SHINE FSAR Section 7.7.1.3.7, Fire Protection, describes that the connection from the radiation monitoring components to the ESFAS or TRPS have certifications that demonstrate the ability to inhibit the propagation of flame in the event of a fire. SHINE FSAR Section 7.7.1.3.8, Natural Phenomena Hazards and Dynamic Effects, describes that process radiation monitors are Seismic Category I, designed in accordance with Section 8 of IEEE Std. 344-2013, IEEE Standard for Seismic Qualification of Equipment for Nuclear Power Generating Stations. SHINE FSAR Section 7.7.5.3.3, Quality, describes that the American National Standards Institute (ANSI) N13.1-1999, Sampling and Monitoring Release of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities, was applied to the design of the facility effluent monitors. However, the FSAR does not include information of how the radiation monitoring system meets these requirements.
- 1. Confirm that the radiation monitors equipment has been tested and qualified for the environmental conditions at the installed locations over the lifetime of the facility and/or describe the testing and qualification process.
- 2. Update the SHINE FSAR to include a summary explanation of how the radiation monitors meet SHINE-specific requirements for seismic, electrical, and other conditions anticipated within the facility.
Page 17 of 22 The information requested is necessary to support the following finding in Section 7.7 of NUREG-1537, Part 2:
The systems and equipment should be designed for reliable operation in the environment in which they will function.
SHINE Response The safety-related process radiation monitors are qualified to SHINE-specific requirements by the vendor. A discussion of the environmental, seismic, and electromagnetic interference (EMI)/radio frequency interference (RFI) qualifications testing of the safety-related process radiation monitors are as follows.
Environmental Qualification Safety-related process radiation monitors are environmentally qualified using guidance provided in Sections 4.1, 5.1, 6.1, and 7 of IEEE Standard 323-2003, Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations (Reference 9). The safety-related process radiation monitors are qualified to the environmental parameters provided in Tables 7.2-1, 7.2-3, and 7.2-6 of the FSAR.
Seismic Qualification The safety-related process radiation monitors are seismically qualified in accordance with Section 8 of IEEE Standard 344-2013, Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Generating Stations (Reference 10) using triaxial testing.
EMI/RFI Qualification EMI/RFI qualification of the safety-related process radiation monitors is performed by testing for emissions, susceptibility, and power surge withstand capability. The safety-related process radiation monitors will be grounded in accordance with Section 5.2.1 of IEEE 1050-2004, Guide for Instrumentation and Control Equipment Grounding in Generating Stations (Reference 11).
SHINE has revised Subsections 7.7.1.3 and 7.7.1.4 of the FSAR to enhance the explanation of how the safety-related process radiation monitors are qualified for the seismic, environmental, and electromagnetic conditions anticipated in the facility. A markup of the FSAR incorporating these changes is provided as Attachment 1.
RAI 7-35 NUREG-1537, Part 1, Chapter 7, Instrumentation and Control Systems, states:
In this chapter, the applicant should discuss the bases of technical specification limiting safety system settings (LSSSs), limiting conditions of operation (LCOs), and surveillance requirements for the I&C systems....
NUREG-1537, Part 2, Section 7.7, Radiation Monitoring Systems, describes that the systems and equipment should be readily tested and capable of being accurately calibrated. This section also describes that the bases of TSs, including surveillance tests and intervals, should be
Page 18 of 22 sufficient to ensure that the systems will be operable and will perform their designed functions.
Please identify the FSAR section that includes this information. See questions 1 and 4 below.)
Subparagraph (c)(3) of 10 CFR 50.36 states: Surveillance requirements [(SRs)] are requirements relating to test, calibration, or inspection to assure that the necessary quality of systems and components is maintained, that facility operation will be within safety limits, and that the limiting conditions for operation will be met. (Identify the FSAR section that describes how the SRs for the radiation monitoring systems ensure the necessary quality of systems and components is maintained, that facility operation will be within safety limits, and that the limiting conditions for operation will be met. See questions 1 and 4 below.)
SHINE FSAR Section 7.7.5.4.1, Technical Specifications, states, in part, that [c]ertain material in this section provides information that is used in the technical specifications, but does not provide additional specificity of how SR frequencies, completion times, and actions in TS Table 3.7.1-a ensure radiation levels within the facility and radiation released to the environment will be within allowable limits when channels are inoperable. Section 7.7.5.4.1 states, in part, that significant material is also applicable to, and may be referenced by, the bases that are described in the technical specifications. Information in the TS bases should summarize information provided in the FSAR. Information in the TS bases may provide details to partially address the questions below. If so, this information should be incorporated into the FSAR, as appropriate.
SHINE FSAR Section 7.7.1.2.1, Instrumentation and Controls, describes that the safety-related process radiation monitor setpoints were selected based on analytical limits and the monitors are periodically functionally tested and maintained. Further, SHINE FSAR Section 7.7.1.4.3, Setpoints, Calibration and Surveillance, notes that these monitors are tested periodically in accordance with SHINE TS to verify operability, and that they are calibrated using commercial radionuclide standards. SHINE TS SR 3.7.1 (Revision 4) defines the frequency for testing the safety-related radiation monitors, and SHINE TS SR 3.7.2 defines the frequency for testing the effluent monitors.
In addition, the TS bases describes that the scope of SHINE TS LCO 3.7.1 begins at the radiation monitoring input devices, includes the associated safety function modules (SFMs), and extends to the inputs to the scheduling, bypass, and voting modules (SBVMs) or scheduling and bypass modules (SBMs). However, SHINE TS LCOs 3.2.1 and 3.2.2 identify the SRs for the SFM, SBVM or SBM for the TRPS and ESFAS, respectively. Based on this information these surveillances may overlap certain components, even though their surveillance frequency is different. The SHINE FSAR does not include sufficient information for the NRC staff to understand how these systems will be tested and maintained to ensure operability.
It is also not clear how the monitored locations in SHINE TS Table 3.7.1-a correlates to all of the 24 safety related process monitors listed in Table 7.7-1. It is also not clear how certain actions for multiple inoperable channels, such as damper closure, to compensate for the systems inability to automatically initiate the associated protective action describe in FSAR Sections 7.7.1.3.1 and 7.7.1.4.1.
- 1. Per Section 14.1 of the FSAR, Technical Specifications, SHINE states the TS were developed following the format and content guidance of ANSI/ANS-15.1-2007. Explain the reason for not having checks and calibrations in the TS for CAMS, RAMS, and effluent monitors (described in Table 7.7-2 and 7.7-3 in the FSAR) as established in
Page 19 of 22 Section 4.7 of ANSI/ANS-15.1, 2007, The Development of Technical Specifications for Research Reactors, provides guidance for radiation monitoring systems and effluents.
- 2. Describe how the SHINE FSAR Table 7.7-1, Safety-Related Process Radiation Monitors, corresponds to SHINE TS Table 3.7.1-a, Safety-Related Radiation Monitoring Instruments. Update the SHINE FSAR and/or TS to ensure consistent labeling for each radiation monitor.
- 3. Update the SHINE FSAR to describe how the surveillance frequencies were selected, considering how the whole instrument channel would be surveilled to ensure the continued operability of the radiation monitors when required.
- 4. Update the SHINE FSAR to explain how the scope of SHINE TS LCOs 3.2.1 and 3.2.2 and the scope of SHINE TS LCO 3.7.1 demonstrate operability of the radiation monitors.
The information requested is necessary to support the following finding in Section 7.7 of NUREG-1537, Part 2:
The bases of technical specifications, including surveillance tests and intervals, should be sufficient to ensure that the systems will be operable and will perform their designed functions.
SHINE Response
- 1. Section 1.2.1 of ANSI/ANS-15.1-2007, The Development of Technical Specifications for Research Reactors (Reference 12) states, Only those operational parameters and equipment requirements directly related to verifying and preserving that safe envelope shall be listed. As described in Subsections 7.7.3.1, 7.7.4.1, and 7.7.5.1, the CAMS, the RAMS, and the SRMS do not perform a safety function. Therefore, limiting conditions for operation (LCOs) and surveillance requirements (i.e., checks and calibrations) related to these nonsafety-related radiation monitoring systems are not included in the technical specifications. The safety-related process radiation monitors listed in LCO 3.7.1 of the technical specifications satisfy the requirements for monitoring systems provided in Section 3.7.1 of ANSI/ANS-15.1-2007. The CAMS, RAMS, and SRMS provide defense-in-depth for the safety-related process radiation monitors, as described in the SHINE Response to Part (c) of RAI 7-30. Calibration and testing of the RAMS, CAMS, and SRMS is described in Subsections 7.7.3.4, 7.7.4.4, and 7.7.5.4 of the FSAR, respectively.
SHINE has revised Subsection 7.7.5.4.1 of the FSAR to clarify the non-applicability of the SHINE technical specifications to the SRMS. A markup of the FSAR incorporating these changes is provided as Attachment 1. SHINE has also revised LCO 3.7.2 of the technical specifications to remove the SRMS from the scope of the surveillance requirements and to modify the action to report exceeding the limit. A markup of the technical specifications incorporating these changes is provided as Attachment 2.
- 2. Table 7.7-1 of the FSAR and Table 3.7.1-a of the technical specifications represent the same safety-related process radiation monitors. While SHINE grouped several safety-related process radiation monitors identified in Table 7.7-1 of the FSAR into a single row in Table 3.7.1-a of the technical specifications, the labeling between these tables is
Page 20 of 22 consistent. The correlation between safety-related process radiation monitors listed in Table 3.7.1-a of the technical specifications and Table 7.7-1 of the FSAR is as follows:
Row a. in Table 3.7.1-a of the technical specifications corresponds to unit 1 in Table 7.7 1 of the FSAR; Row b. in Table 3.7.1-a of the technical specifications corresponds to units 2, 6, 7, and 10 in Table 7.7-1 of the FSAR; Row c. in Table 3.7.1-a of the technical specifications corresponds to units 3, 4, 5, 8, and 9 in Table 7.7-1 of the FSAR; Row d. in Table 3.7.1-a of the technical specifications corresponds to unit 11 in Table 7.7-1 of the FSAR; Row e. in Table 3.7.1-a of the technical specifications corresponds to unit 12 in Table 7.7-1 of the FSAR; Row f. in Table 3.7.1-a of the technical specifications corresponds to units 17, 18, 19, 20, 21, 22, 23, and 24 in Table 7.7-1 of the FSAR; Row g. in Table 3.7.1-a of the technical specifications corresponds to units 13, 14, and 15 in Table 7.7-1 of the FSAR; Row h. in Table 3.7.1-a of the technical specifications corresponds to unit 16 in Table 7.7-1 of the FSAR; and Row i. in Table 3.7.1-a of the technical specifications corresponds to units 25, 26, and 27 in Table 7.7-1 of the FSAR.
Table 3.7.1 of the technical specifications provides actions for inoperable channels. Actions 2, 3, 4, 5, and 8 of Table 3.7.1 of the technical specifications provide actions that involve closing dampers. These actions compensate for the inoperability of the associated safety-related process radiation monitor by isolating the ventilation flow path(s) from the area of potential contamination. By placing these dampers in the actuated state, the safety function of the inoperable safety-related process radiation monitor is satisfied.
As the labeling between Table 3.7.1-a of the technical specifications and Table 7.7-1 of the FSAR is consistent, no additional need to modify the licensing basis was identified.
- 3. The surveillance frequencies for the radiation monitoring instruments included in LCO 3.7.1 of the technical specifications were selected consistent with the guidance provided in ANSI/ANS 15.1-2007. These frequencies are adequate to demonstrate operability of the safety-related process radiation monitors and SFMs. The surveillance frequencies for the TRPS logic and actuation divisions and ESFAS logic and actuation divisions are provided in LCOs 3.2.1 and 3.2.2 of the technical specifications, respectively, and address operability of the channel from the inputs to the SBVMs or SBMs, which come from the SFMs, and extends through the output of the equipment interface modules (EIMs), which go to the actuated components. These frequencies, some of which rely on end-to-end self testing, are described in Subsections 7.4.4.4 and 7.5.4.5 of the FSAR. The frequency of surveillance testing of actuated components is provided in the LCOs for those actuated components and is based upon the guidance of ANSI/ANS 15.1-2007 and industry experience.
SHINE has revised Subsection 7.7.1.4.3 of the FSAR to include a description of the surveillance frequencies associated with the safety-related process radiation monitors. A markup of the FSAR incorporating these changes is provided as Attachment 1.
Page 21 of 22
- 4. LCOs 3.2.1 and 3.2.2 of the technical specifications are provided for the TRPS logic and actuation divisions and ESFAS logic and actuation divisions, respectively. End-to-end self testing, as described in Subsections 7.4.4.4 and 7.5.4.5 of the FSAR, demonstrates operability of the channel from the inputs to the SBVMs or SBMs, which come from the SFMs, and extends through the output of the EIMs, which go to the actuated components.
LCO 3.7.1 of the technical specifications addresses radiation monitoring input devices to the TRPS or ESFAS, and the associated trip determination portions of the TRPS or ESFAS. The scope of the LCO for each channel begins at the radiation monitoring input devices, includes the SFMs and extends to the inputs to the SBVMs or SBMs. The surveillance requirements associated with LCO 3.7.1 of the technical specifications verify the operability of the channel from the safety-related process radiation monitor to the SBVMs or SBMs. These surveillances, combined with the testing described above, demonstrate operability from the safety-related process radiation monitor to the output switching logic.
Operability from the output of the EIM to the actuated component associated with a safety related process radiation monitor is addressed in the LCOs related to the individual actuated components (i.e., LCOs 3.4.1, 3.4.3, 3.4.4, 3.6.2, 3.8.9, and 3.8.10 of the technical specifications).
The scope of the LCOs described above demonstrate operability of a safety-related radiation monitor channel from the detector to the actuated component.
SHINE has revised Subsection 7.7.1.4.3 of the FSAR to include a description of the operability requirements associated with the safety-related process radiation monitors. A markup of the FSAR incorporating these changes is provided as Attachment 1.
References
- 1. NRC letter to SHINE Medical Technologies, LLC, SHINE Medical Technologies, LLC - Request for Additional Information Related to the Radiation Monitoring System(s)
(EPID No. L 2019-NEW-0004), dated January 11, 2022 (ML22007A217)
- 2. SHINE Medical Technologies, LLC letter to the NRC, SHINE Medical Technologies, LLC Application for an Operating License, dated July 17, 2019 (ML19211C143)
- 3. SHINE Technologies, LLC letter to NRC, Application for an Operating License Supplement No. 13 and Response to Request for Additional Information, dated November 22, 2021
- 4. Institute of Electrical and Electronics Engineers, Standard Criteria for Digital Computers in Safety Systems of Nuclear Power Generating Stations, IEEE Standard 7-4.3.2-2003, New York, NY
- 5. American National Standards Institute/American Nuclear Society, Guidelines for the Verification and Validation of Scientific and Engineering Computer Programs for the Nuclear Industry, ANSI/ANS-10.4-1987, La Grange Park, IL
- 6. American National Standards Institute/American Nuclear Society, Verification and Validation of Non-Safety-Related Scientific and Engineering Computer Programs for the Nuclear Industry, ANSI/ANS-10.4-2008, La Grange Park, IL
Page 22 of 22
- 7. SHINE Medical Technologies, LLC letter to NRC, Application for an Operating License Response to Request for Additional Information, dated August 27, 2021 (ML21239A049)
- 8. Institute of Electrical and Electronics Engineers, Standard Criteria for Independence of Class 1E Equipment and Circuits, IEEE Standard 384-2008, New York, NY
- 9. Institute of Electrical and Electronics Engineers, Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations, IEEE Standard 323-2003, New York, NY
- 10. Institute of Electrical and Electronics Engineers, Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Generating Stations, IEEE Standard 344-2013, New York, NY
- 11. Institute of Electrical and Electronics Engineers, Guide for Instrumentation and Control Equipment Grounding in Generating Stations, IEEE Standard 1050-2004, New York, NY
- 12. The Development of Technical Specifications for Research Reactors, ANSI/ANS-15.1-2007, American National Standards Institute/American Nuclear Society, 2007.
ENCLOSURE 2 ATTACHMENT 1 SHINE TECHNOLOGIES, LLC SHINE TECHNOLOGIES, LLC APPLICATION FOR AN OPERATING LICENSE SUPPLEMENT NO. 18 AND RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION FINAL SAFETY ANALYSIS REPORT CHANGES (MARK-UP)
Chapter 7 - Instrumentation and Control Systems Radiation Monitoring Systems SHINE Medical Technologies 7.7-1 Rev. 5 7.7 RADIATION MONITORING SYSTEMS This section describes systems and components that perform radiation monitoring functions within the SHINE facility. Radiation monitoring systems and components include:
safety-related process radiation monitors included as part of the engineered safety features actuation system(ESFAS), target solution vessel(TSV) reactivity protection system(TRPS), and tritium purification system (TPS);
nonsafety-related process radiation monitors included as part of other facility processes; area radiation monitoring consisting of the radiation area monitoring system(RAMS);
continuous air monitoring consisting of the continuous air monitoring system(CAMS);
and effluent monitoring consisting of the stack release monitoring system(SRMS).
The objective of the radiation monitoring systems is to:
provide facility control room personnel with a continuous record and indication of radiation levels at selected locations within processes and within the facility; provide local radiation information and alarms for personnel within the facility; provide input to safety-related control systems to actuate safety systems; and provide the ability to monitor radioactive releases to the environment.
A diagram showing how the facility radiation monitoring systems relate to the overall facility instrumentation and control(I&C) architecture is provided as Figure7.1-1.
7.7.1 SAFETY-RELATED PROCESS RADIATION MONITORING 7.7.1.1
System Description
Safety-related process radiation monitors provide input to the safety-related ESFAS or TRPS control systems. These components monitor for either fission products or tritium. The type of safety-related process radiation monitor (fission product or tritium) is selected based on the location and identity of radioactive material present. Beta detection radiation monitors monitor for gaseous fission product release and provide input to the ESFAS or TRPS. Gamma-ray radiation monitors monitor for release of fission products through leakage into the molybdenum extraction and purification system (MEPS) hot water loop and provide input to the ESFAS. Safety-related tritium monitors are part of the TPS. The TPS monitors are installed within various portions of the TPS to detect potential tritium releases, provide actuation signalsinputs to the ESFAS controls, and provide interlock inputs to the TRPS controls. Information from safety-related process radiation monitors is displayed in the facility control room on the operator workstations (via the process integrated control system [PICS]).
A list of safety-related process radiation monitors is provided in Table7.7-1.
Safety-related process radiation monitors that monitor for fission products use digital detectors to provide an analog signal to the TRPS or ESFAS. Safety-related process radiation monitors that monitor for tritium use solely analog technology.
Logic diagrams depicting how the safety-related process radiation monitors provide inputs to TRPS and ESFAS are provided in Figure7.4-1 and Figure7.5-1, respectively.
Chapter 7 - Instrumentation and Control Systems Radiation Monitoring Systems SHINE Medical Technologies 7.7-2 Rev. 5 7.7.1.2 Design Criteria The SHINE facility design criteria applicable to the safety-related process radiation monitors are addressed in this section. The generally-applicable SHINE facility design criteria 1, 2, and 4 apply to the safety-related process radiation monitors. The safety-related process radiation monitors are designed, fabricated, and erected to quality standards commensurate to the safety functions to be performed, and are qualified to perform these safety functions during external events and within the environmental conditions associated with normal operation, maintenance, and testing. These elements of the safety-related process radiation monitor design contribute to satisfying SHINE facility design criteria 1, 2, and 4. SHINE facility design criteria 13 and 38 also apply to the safety -related process radiation monitors.
7.7.1.2.1 Instrumentation and Controls SHINE Design Criterion 13 - Instrumentation is provided to monitor variables and systems over their anticipated ranges for normal operation, for anticipated transients, and for postulated accidents as appropriate to ensure adequate safety, including those variables and systems that can affect the fission process, the integrity of the primary system boundary, the primary confinement and its associated systems, and the process confinement boundary and its associated systems. Appropriate controls are provided to maintain these variables and systems within prescribed operating ranges.
Safety-related radiation monitoring channels produce a full-scale reading when subject to radiation fields higher than the full-scale reading; however, they are expected to remain on-scale during accident conditions. The safety-related process radiation monitors that provide actuation signals are designed to function in the range necessaryduring normal operation, anticipated transients, and design basis accidents to a level required to detect accident conditions and provide safety-related inputs to the ESFAS and TRPS control systemsto initiate protective actions (Subsection7.7.1.3.1). Setpoints are selected based on analytical limits and calculated to account for known uncertainties in accordance with the setpoint determination methodology and the monitors are periodically functionally tested and maintained (Subsection7.7.1.4.3).
7.7.1.2.2 Monitoring Radioactivity Releases SHINE Design Criterion 38 - Means are provided for monitoring the primary confinement boundary, hot cell, and glovebox atmospheres to detect potential leakage of gaseous or other airborne radioactive material. Potential effluent discharge paths and the plant environs are monitored for radioactivity that may be released from normal operations, including anticipated transients, and from postulated a ccidents.
The safety-related process radiation monitors provide radiation monitoring for the primary confinement boundary, hot cell, and glovebox atmospheres, provide radiation monitoring of the MEPS hot water loop, and monitor effluent release paths (Subsection7.7.1.4.1). The monitors are designed to operate during normal conditions, anticipated transients, and design basis accidents (Subsection7.7.1.4).
Chapter 7 - Instrumentation and Control Systems Radiation Monitoring Systems SHINE Medical Technologies 7.7-3 Rev. 5 7.7.1.3 Design Bases 7.7.1.3.1 Design Bases Functions The safety functions of the process radiation monitors are: (1)to detect radioactivity in excess of normal levels and provide an actuation signalinput to the ESFAS or TRPS controls, or (2)to provide input to TRPS for interlocking the operation of the neutron driver. Additional discussion of TRPS and ESFAS functions, interlocks, and bypasses is provided in Section7.4 and Section7.5, respectively.
Each location that requires process radiation monitoring as determined by the safety analysis is equipped with safety-related process radiation monitors. The specified minimum number of process radiation monitors (channels) is only required to be operable when the location being monitored contains radioactive material, as specified in Table7.7-1.
Process radiation monitors are selected for compatibility with the normal and postulated accident environmental and radiological conditions.
A list of safety-related process radiation monitors, specifying the monitored location, number of sensing channels provided, and operability requirements, is provided in Table7.7-1.
The variables to be monitored and their ranges, accuracies, setpoints, and response times of safety-related process radiation monitors are provided in Table7.4-1 and Table7.5-1. Instrument accuracies are appropriate for the associated setpoints. Signal processing time for the ESFAS and TRPS is provided in Subsection7.4.5.2.3.
Safety-related radiation monitoring channels produce a full-scale reading when subject to radiation fields higher than the full-scale reading, however, they are expected to remain on-scale during accident conditions. The safety-related process radiation monitors that provide actuation signals are designed to function in the range necessaryduring normal operation, anticipated transients, and design basis accidents to a level required to detect accident conditions and provide safety-related inputs to the ESFAS and TRPS control systems.to initiate protective actions. If the measured radiation field goes above the full-scale, the analog output from the safety-related process radiation monitor will be equivalent to the full-scale reading. The TRPS or ESFAS will process this signal as a valid, full-scale value. For defense-in-depth, the radiologically controlled area (RCA) exhaust, general area direct radiation levels, and general area airborne particulates are monitored by stack release, radiation area, and continuous area monitors, respectively.
7.7.1.3.2 Operating Conditions During normal operation, the process radiation monitors are designed to operate in the normal environmental conditions (temperature, pressure, relative humidity) identified in Tables7.2-2 through 7.2-5 for an expected 20-year lifetime of the equipment.
The monitors are designed to operate in the transient conditions identified in Tables7.2-1 through 7.2-5 until the associated protective function has continued to completion.
Chapter 7 - Instrumentation and Control Systems Radiation Monitoring Systems SHINE Medical Technologies 7.7-4 Rev. 5 7.7.1.3.3 Single Failure At least tTwo or three redundant and independent safety-related process radiation monitors are provided for each protection function input parameter, each providing input to the associated division of the safety-related control systemTRPS or ESFAS. Redundancy in monitors ensures that a failure of one monitor will not prevent the control systemTRPS or ESFAS from performing its safety function.
The Channel A safety-related process radiation monitors receive power from Division A of the uninterruptible power supply system (UPSS), and Channel B safety-related process radiation monitors receive power from UPSS Division B. Channel C safety-related process radiation monitors, when provided, receive auctioneered power from both UPSS Division A andB. For loss of power to a safety-related process radiation monitor, analog outputs to the TRPS or ESFAS fail low, and the partial trip information for the failed channel is determined by the associated safety function modules (SFMs) out-of-service status (Subsections7.4.4.3 and 7.5.4.4).
Therefore, no single failure of a detector, control division, or power division will prevent the safety-related control system from performing its safety function.
7.7.1.3.4 Independence Safety-related process radiation monitors provide analog communication to the ESFAS and TRPS controls. Channel communication independence is maintained by implementing separate hardwired connections to the separate ESFAS or TRPS controls divisions.
Radiation monitoring data provided to nonsafety control systems is through one-way isolated outputs.
Physical separation is maintained between divisions of safety-related process radiation monitors, and division independence is maintained from the safety-related process radiation monitors, through the TRPS and ESFAS, to the devices actuating the protective function (Subsection7.4.5.2.1).
The safety-related process radiation monitors provide analog signals directly to the TRPS and ESFAS and do not interface electrically with any nonsafety-related system. Credible failures of nonsafety-related systems would not affect the functions of the safety-related process radiation monitors, demonstrating communications independence.
Safety-related process radiation monitors from separate divisions are physically separated from each other and independently powered from the associated UPSS division (Subsection7.7.1.3.3). The UPSS provides safety-related power to system loads, including the safety-related process radiation monitors (Subsection8a2.2.3).
7.7.1.3.5 Redundancy Each location that requires engineered safety features to actuate in response to radiation levels, as determined by the safety analysis, is provided with at least two independent safety-related process radiation monitors, designated as Channels A and B. For locations where spurious
Chapter 7 - Instrumentation and Control Systems Radiation Monitoring Systems SHINE Medical Technologies 7.7-5 Rev. 5 actuationfailure of a process radiation monitor could significantly impact overall facility operation, a third sensing division (Division C) is provided.
7.7.1.3.6 Human Factors, Display and Recording Selection and display of process radiation monitor variables are designed with consideration of human factors engineering principles.
See Section7.6 for additional discussion of information presented to facility operators and recorded for future use.
7.7.1.3.7 Fire Protection Safety-related monitors in different channels are located in separate fire areas when practical.
Physical separation is used to achieve separation of redundant sensors. Wiring for redundant channels uses physical separation and isolation to provide independence for circuits. Separation of wiring is achieved using separate wireways and cable trays for each channel. Spatial separation between cable and raceway groups is in accordance with IEEE 384-2008 (IEEE, 2008), Section 5.1.1.2, Section 5.1.3.3 Table 1, and Section 5.1.4 Table 2.
Cable, wire, and electrical connectors utilized to connect radiation monitoring components to the ESFAS or TRPS have certifications that demonstrate the ability to inhibit the propagation of flame in the event of a fire. The certifications use recognized industry standards or guidance.
Noncombustible and heat resistant materials are used where practical in the design.
7.7.1.3.8 Natural Phenomena Hazards and Dynamic Effects The process radiation monitors are installed in the seismically qualified portion of the main production facility where they are protected from earthquakes, tornadoes, and floods (Subsections 7.4.3.6 and 7.5.3.5). The process radiation monitors are Seismic Category I, designed and tested using triaxial testing in accordance with Section 8 of IEEE Standard 344-2013 (IEEE, 2013) (Subsection 7.7.1.3.8). Hurricanes, tsunamis, and seiches are not credible events at the SHINE facility (Subsections 2.4.5.1, 2.4.2.7, and 2.4.5.2).
7.7.1.3.9 Quality The safety-related process radiation monitors are designed, procured, fabricated, erected, and tested in accordance with the SHINE Quality Program Description (QAPD). Quality records applicable to the design, procurement, fabrication, erection, and testing are maintained.
The following codes and standards are applied to the design of the safety-related process radiation monitors:
IEEE Standard 323-2003, IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations (IEEE, 2003b), invoked as guidance to support environmental qualification as described in Subsection7.7.1.4.
IEEE 344-2013, Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations (IEEE, 2013), Section 8.
Chapter 7 - Instrumentation and Control Systems Radiation Monitoring Systems SHINE Medical Technologies 7.7-6 Rev. 5 IEEE 384-2008, IEEE Standard Criteria for Independence of Class1E Equipment and Circuits (IEEE, 2008); invoked for separation of safety-related and nonsafety-related cables and raceways, as described in Subsection8a2.1.3 and Subsection8a2.1.5.
Section 5.2.1 of IEEE Standard 1050-2004, IEEE Guide for Instrumentation and Control Equipment Grounding in Generating Stations (IEEE, 2004b); invoked as guidance to support electromagnetic compatibility qualification for digital I&C equipment.
7.7.1.4 Operation and Performance The safety-related process radiation monitors are designed to operate under normal conditions, during anticipated transients, and during design basis accidents such that they will perform their safety function. The safety-related process radiation monitors are qualified to the environmental parameters provided in Tables7.2-1, 7.2-3, and 7.2-6 by applying the guidance of Sections 4.1, 5.1, 6.1, and 7 of IEEE Standard 323-2003 (IEEE, 2003b).
The safety-related process radiation monitors demonstrate electromagnetic interference (EMI)/radio-frequency interference (RFI) qualification through emissions testing, susceptibility testing, and surge withstand capability testing. The safety-related process radiation monitors are grounded in accordance with Section 5.2.1 of IEEE Standard 1050-2004 (IEEE, 2004b).
7.7.1.4.1 Functionality TRPS process radiation monitors monitor the ventilation line from the primary closed loop cooling system (PCLS) expansion tanks (i.e., radiological ventilation zone 1 exhaust subsystem [RVZ1e]
irradiation unit[IU] cell radiation monitors). These monitors provide an input to the TRPS, where it is compared with a setpoint. An actuation signal is generated, as depicted in Figure7.4-1, when radiation levels exceed pre-determined limits, indicative of a release of target solution or fission products within the PCLS or the primary confinement atmosphere (with which the tank communicates). The actuation results in an IU Cell Safety Actuation for that unit.
ESFAS process monitors associated with the supercell monitor the ventilation exhaust from each hot cell and provide an input to the ESFAS, where it is compared with a setpoint. An actuation signal is generated, as depicted in Figure7.5-1, when radiation levels exceed pre-determined limits, indicative of a release of target solution or fission products within that hot cell. The actuation results in isolation of the affected hot cell.
ESFAS process monitors associated with the radiological ventilation zone1(RVZ1) and radiological ventilation zone2(RVZ2) exhaust are designed to provide an input to the ESFAS, where it is compared to a setpoint. An actuation signal is generated, as depicted in Figure7.5-1, when radiation levels in the RCA ventilation exhaust systems exceed pre-determined limits, indicative of a failure of a confinement boundary within the facility. The actuation results in isolation of RVZ1, RVZ2, and radiological ventilation zone3(RVZ3) ventilation.
The ESFAS process monitors associated with the MEPS hot water loop are designed to provide an input to the ESFAS, where it is compared to a setpoint. An actuation signal is generated, as depicted in Figure7.5-1, when radiation levels exceed pre-determined limits, indicative of a leak of target solution within the loop. The actuation results in isolation of the affected MEPS hot water loop.
Chapter 7 - Instrumentation and Control Systems Radiation Monitoring Systems SHINE Medical Technologies 7.7-7 Rev. 5 The TPS process monitors associated with tritium confinement are designed to provide an input to the ESFAS, where it is compared to a setpoint. An actuation signal is generated, as depicted in Figure7.5-1, when tritium concentrations within the TPS gloveboxes exceed predetermined limits, indicative of a failure of TPS process equipment and release of tritium into the TPS glovebox. The actuation results in isolation of the tritium confinement and ventilation associated with the TPS room.
The TPS tritium monitors associated with the TPS exhaust to facility stack are designed to provide an input to the ESFAS, where it is compared to a setpoint. An actuation signal is generated, as depicted in Figure7.5-1, when tritium concentrations in the TPS exhaust to facility stack exceed predetermined limits, indicative of a release of tritium out of the TPS. The actuation results in isolation of the TPS process vent exhaust lines and ventilation associated with the TPS room.
Additional discussion of safety-related process radiation monitor functionality is provided in Sections7.4 and 7.5.
7.7.1.4.2 Reliability, Adequacy, and Timeliness Two safety-related process radiation monitors are provided for each location requiring monitoring. For locations where spurious actuationfailure of the process radiation monitor could significantly impact overall facility operation, a third sensing channel (Channel C) is provided for two-out-of-three voting capability.
Instrument ranges and response times are provided in Tables7.4-1 and 7.5-1.
7.7.1.4.3 Setpoints, Calibration and Surveillance Setpoints for safety-related process radiation monitors are selected based on analytical limits and calculated to account for known uncertainties in accordance with the setpoint determination methodology described in Subsection7.2.1.
Monitors are periodically functionally tested and maintained in accordance with the SHINE technical specifications to verify operability. The surveillance frequencies for the safety-related process radiation monitoring instruments included in the technical specifications were selected consistent with the guidance provided in American National Standards Institute/American Nuclear Society (ANSI/ANS) 15.1-2007, The Development of Technical Specifications for Research Reactors (ANSI/ANS, 2007). The surveillance requirements for the safety-related process radiation monitoring instruments included in the technical specifications verify the operability of the channel from the safety-related process radiation monitor to the inputs to the scheduling, bypass, and voting module (SBVM) or scheduling and bypass module (SBM) located in the TRPS or ESFAS. Testing of the logic and actuation divisions of the TRPS and ESFAS is described in Subsections7.4.4.4 and 7.5.4.5.
Instrument background count rate is observed to ensure proper functioning of the monitors.
Safety-related process radiation monitors located in a low background area are equipped with a check source to be able to verify proper operation.
Chapter 7 - Instrumentation and Control Systems Radiation Monitoring Systems SHINE Medical Technologies 7.7-14 Rev. 5 7.7.5.4 Operation and Performance The SRMS units are designed to operate under normal facility conditions and to detect radiation that may be indicative of anticipated transients or design basis accidents.
The SRM is used to monitor the main facility stack, which is the normal release path for gaseous effluents from the PVVS and RCA ventilation systems. The SRM includes a mass flow controller to regulate sample flow rate in the isokinetic region relative to stack flow. A vacuum pump is used to draw sampled air through particulate and iodine filter cartridges, which are removed and analyzed periodically. The sampled air is then drawn into a sample chamber, which houses a beta detector used to measure the noble gas radionuclides. The ratemeter for the beta radiation monitor indicates and displays the radiation level inside the sampler from the sampled air. From the sampler, the air is drawn through the flow controller assembly, pump, and exhausted into the return line. Downstream of the particulate and iodine filter, a connection for the tritium detection system is provided. The tritium monitor has its own pump and flow control. The tritium detector is a passive sampler collecting system (i.e., bubble system) to continuously collect and concentrate elemental tritium and tritiated water in small vials. The contents of the vials are assayed using a scintillation counter at regular intervals.
The CDBEM monitors noble gases at the exhaust of the PVVS carbon delay beds using a sampling system. Redundant particulate and iodine filters are installed in-line with the effluent stream, upstream of the safety-related exhaust point, which operates at a much lower flow rate (approximately 16 standard cubic feet per minute) than the main facility stack. The safety-related exhaust point is only used while nitrogen purge is in operation. The PVVS system does not receive gases from process locations expected to contain tritium; therefore, the CDBEM does not include a tritium monitor. Although the CDBEM monitors a safety-related point in the PVVS system, the CDBEM is not required to perform a safety function. The monitoring functions provided by the CDBEM are described in Subsection7.7.5.1. See Section9b.6 for additional discussion on the PVVS and nitrogen purge operations.
The initial channel calibration for the SRM and CDBEM noble gas detectors is performed using standards traceable to NIST.
7.7.5.4.1 Technical Specifications Certain material in this section provides information that is used in theThere are no technical specifications. This includes limiting conditions for operation, setpoints, design features, and means for accomplishing surveillances. In addition, significant material is also applicable to, and may be referenced by, the bases that are described in the technical specifications the SRMS.
7.
7.6 CONCLUSION
Radiation monitoring within the SHINE facility is performed by multiple radiation monitoring processes. The radiation monitoring supports facility control room operations, provides information and alarms for personnel within the facility, provides input to safety-related control systems to actuate safety systems, and provides the ability to monitor radioactive releases to the environment.
ENCLOSURE 2 ATTACHMENT 2 SHINE TECHNOLOGIES, LLC SHINE TECHNOLOGIES, LLC APPLICATION FOR AN OPERATING LICENSE SUPPLEMENT NO. 18 AND RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION TECHNICAL SPECIFICATIONS MARK-UPS
Page 3.7-4 Revision 56 Monitored Location Setpoint and Monitored Material Required Channels Applicability (per IU, TPS train, or monitored location)
Action
- i.
MEPS heating loop extraction area A/B/C 1000 mR/hr Fission products 2
(per hot cell)
Target solution or radioactive process fluids present in the associated hot cell 11, 12 LCO 3.7.2 The annually averaged concentration of radioactive material released in gaseous effluents to unrestricted areas shall be limited to 2800 times the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 1.
Applicability Facility not Secured Action According to Table 3.7.2 SR 3.7.2
- 1. Total curies released shall be assessed monthly.
- 2. A Channel Calibration of the stack release monitor shall be performed annually.
- 3. A Channel Calibration of the PVVS carbon delay bed effluent monitor shall be performed annually.
Table 3.7.2 Gaseous Effluents Actions Action Completion Time
- 1.
If the monthly curie assessment exceeds 1/12th of the established
- limit, Verify the annual curie assessment is within the limitSubmit a Special Report as described in Section 5.8.2.
24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />sAs described in Section 5.8.2
Page B 3.7-8 Revision 56 Basis 3.7.2 LCO Release limits on radioactive effluents ensure the facility does not release excessively high levels of radioactive effluents, as described in FSAR Section 11.1. The factor of 2800 times the values listed in 10 CFR 20, Appendix B, Table 2, Column 1 is based on the SHINE site-specific atmospheric dispersion factor (/Q) value of 7.1E-5 sec/m3 for the maximally exposed individual (MEI), which is taken to be the nearest point on the site boundary. The estimated annual dose to the MEI is 3.9 mrem, as discussed in FSAR Subsection 11.1.1.1. The factor of 2800 times values listed in 10 CFR 20, Appendix B, Table 2, Column 1 limits the MEI dose to less than 10 mrem.
The stack release monitor provides the ability to monitor the normal effluent release pathway. The carbon delay bed effluent monitor provides information about the health of the PVVS carbon delay beds and provides the ability to monitor the safety-related exhaust point effluent release pathway when it is in use to demonstrate that gaseous effluents from the SHINE Facility are within regulatory limits, as described in FSAR Subsection 7.7.5.
If the monthly curie assessment (SR 3.7.2.1) exceeds 1/12th ofannually averaged concentration of radioactive material released in gaseous effluents exceeds the annual limit, the annual curie assessment shall be verified within the limit within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. This completion time is adequate to properly review assessment data for errors and, if necessary, to verify annual assessment data. The completion time is acceptable because the likelihood of exceeding annual limits within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of exceeding 1/12th the annual limit is lowa Special Report will need to be submitted as described in Section 5.8.2. Additional actions may be taken as necessary to reduce releases of radioactive material to restore or maintain compliance with LCO 3.7.2.
SR The surveillance requirement ensures that the gaseous effluents from normal operations released to uncontrolled areas are within the allowable limits. The stack release monitor and carbon delay bed effluent monitor Channel Calibrations ensure the continued operability of the instruments and the accuracy of the measurements. A stack release monitor or PVVS carbon delay bed effluent monitor input channel consists of the field instrument through the PICS display. The surveillance requirements are consistent with industry experience.By verifying the total curies released on a monthly basis, sufficient time is available to take action, as necessary, to reduce release rates to maintain compliance with LCO 3.7.2.