Dr. Gregory Piefer Chief Executive Officer SHINE Technologies, LLC 3400 Innovation Court Janesville, WI 53546
SUBJECT:
SHINE MEDICAL TECHNOLOGIES, LLC - REQUEST FOR CONFIRMATORY INFORMATION RELATED TO RADIATION PROTECTION PROGRAM AND WASTE MANAGEMENT (EPID NO. L-2019-NEW-0004)
Dear Dr. Piefer:
By letter dated July 17, 2019 (Agencywide Documents Access and Management System Accession No. ML19211C044), as supplemented, SHINE Medical Technologies, LLC (SHINE) submitted to the U.S. Nuclear Regulatory Commission (NRC) an operating license application for its proposed SHINE Medical Isotope Production Facility in accordance with the requirements contained in Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic Licensing of Production and Utilization Facilities. By letter date January 27, 2022 (ML22027A353), SHINE submitted a supplement to the operating license application describing the impacts of phased startup operations. The phased startup operations application supplement describes new or different information from the full facility system descriptions and analyses provided in the final safety analysis report (FSAR) resulting from the SHINE phased approach to initial facility startup and operations.
During the NRC staffs review of SHINEs operating license application, as supplemented, questions have arisen for which confirmatory information is needed. The enclosed request for confirmatory information (RCI) identifies information needed for the NRC staff to continue its review of the SHINE FSAR, submitted in connection with the operating license application, and prepare a safety evaluation report. The specific technical area of the SHINE operating license application covered by this RCI is Chapter 11, Radiation Protection Program and Waste Management.
It is requested that SHINE provide responses to the enclosed RCI within 30 days from the date of this letter. To facilitate a timely and complete response to the enclosed RCI, the NRC staff is available to meet with SHINE to clarify the scope of information and level of detail expected to be included in the RCI response. SHINE may coordinate the scheduling and agendas for any such meetings with the responsible project manager assigned to this project.
In accordance with 10 CFR 50.30(b), Oath or affirmation, SHINE must execute its response in a signed original document under oath or affirmation. The response must be submitted in accordance with 10 CFR 50.4, Written communications. Information included in the response that is considered sensitive or proprietary, that SHINE seeks to have withheld from the public, must be marked in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Any information related to safeguards should be submitted in accordance with July 27, 2022
G. Piefer 10 CFR 73.21, Protection of Safeguards Information: Performance Requirements. Following receipt of the confirmatory information, the NRC staff will continue its evaluation of the subject chapters and technical areas of the SHINE operating license application.
As the NRC staff continues its review of SHINEs operating license application, additional RCIs for other chapters and technical areas may be developed. The NRC staff will transmit any further questions to SHINE under separate correspondence.
If SHINE has any questions, or needs additional time to respond to this request, please contact me at 301-415-2856, or by email to Michael.Balazik@nrc.gov.
Sincerely, Michael Balazik, Project Manager Non-Power Production and Utilization Facility Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Docket No. 50-608 Construction Permit No. CPMIF-001
Enclosure:
As stated cc: See next page Signed by Balazik, Michael on 07/27/22
SHINE Medical Technologies, LLC Docket No. 50-608 cc:
Jeff Bartelme, Director of Licensing SHINE Technologies, LLC 3400 Innovation Court Janesville, WI 53546 Nathan Schleifer, General Counsel SHINE Technologies, LLC 3400 Innovation Court Janesville, WI 53546 Christopher Landers, Director Office of Conversion National Nuclear Security Administration NA 23 U.S. Department of Energy 1000 Independence Avenue, SW Washington, DC 20585 Mark Paulson, Supervisor Radiation Protection Section Wisconsin Department of Health Services P.O. Box 2659 Madison, WI 53701-2659 Test, Research and Training Reactor Newsletter Attention: Amber Johnson Department of Materials Science and Engineering University of Maryland 4418 Stadium Drive College Park, MD 20742-2115 Mark Freitag City Manager P.O. Box 5005 Janesville, WI 53547-5005 Bill McCoy 1326 Putnam Avenue Janesville, WI 53546 Alfred Lembrich 541 Miller Avenue Janesville, WI 53548
SUBJECT:
SHINE MEDICAL TECHNOLOGIES, LLC - REQUEST FOR CONFIRMATORY INFORMATION RELATED TO RADIATION PROTECTION PROGRAM AND WASTE MANAGEMENT (EPID NO. L-2019-NEW-0004) DATED: JULY 27, 2022 DISTRIBUTION:
PUBLIC JBorromeo, NRR MBalazik, NRR NParker, NRR MGavello, NRR HCruz, NRR CCarusone, NRR ZGran, NRR KHsueh, NRR ADAMS Accession Number: ML22206A208 NRR-106 OFFICE NRR/DANU/PM NRR/DANU/LA NRR/DANU/BC NRR/DANU/PM NAME MBalazik NParker JBorromeo MBalazik DATE 7/25/2022 7/26/2022 7/26/2022 7/27/2022 OFFICIAL RECORD COPY
Enclosure OFFICE OF NUCLEAR REACTOR REGULATION REQUEST FOR CONFIRMATORY INFORMATION REGARDING OPERATING LICENSE APPLICATION FOR SHINE MEDICAL TECHNOLOGIES, LLC CONSTRUCTION PERMIT NO. CPMIF-001 SHINE MEDICAL ISOTOPE PRODUCTION FACILITY DOCKET NO. 50-608 By letter dated July 17, 2019 (Agencywide Documents Access and Management System Accession No. ML19211C044), as supplemented, SHINE Medical Technologies, LLC (SHINE) submitted to the U.S. Nuclear Regulatory Commission (NRC) an operating license application for its proposed SHINE Medical Isotope Production Facility in accordance with the requirements contained in Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic Licensing of Production and Utilization Facilities. By letter date January 27, 2022 (ML22027A353), SHINE submitted a supplement to the operating license application describing the impacts of phased startup operations. The phased startup operations application supplement describes new or different information from the full facility system descriptions and analyses provided in the final safety analysis report (FSAR) resulting from the SHINE phased approach to initial facility startup and operations.
During the NRC staffs review of the SHINE operating license application, and the review of the supplement for phased startup operations, questions have arisen for which confirmatory information is needed. This request for confirmatory information (RCI) identifies information needed for the NRC staff to continue its review of the SHINE FSAR, submitted as part of the operating license application, and prepare a safety evaluation report. Specific chapters and technical areas of the SHINE operating license application covered by this RCI include the following:
Chapter 11, Radiation Protection Program and Waste Management Applicable Regulatory Requirements and Guidance Documents Paragraph (b) of 10 CFR 20.1101, Radiation protection programs, states: The licensee shall use, to the extent practical, procedures and engineering controls based upon sound radiation protection principles to achieve occupational doses and doses to members of the public that are as low as is reasonably achievable (ALARA).
RCI 11-1 By letter dated, May 23, 2022 (ML22094A114), the NRC staff issued audit questions to SHINE related to phased startup and operations approach. The NRC staff was seeking to better understand the radiation environments that workers would be exposed to when working in an empty irradiation unit (IU) cell adjacent to an operating IU cell to ensure occupational doses were ALARA. During a review of information made available during the audit, SHINE provided information in response to the NRC staff audit questions 10 and 11.
2 1.
Confirm that the radiological dose estimates are as follows:
a.
The average dose rate in an empty IU cell adjacent to an operating IU cell is approximately 15 millirem per hour (mrem/hr) below the normal light water pool height and less than 5 mrem/hr above the light water pool height. The dose rate in the empty IU cell is approximately 60 mrem/hr at the height of the target solution vessel near the south wall.
b.
The maximum dose rate in an adjacent target solution vessel off-gas system cell is expected to be approximately 60 mrem/hr.
c.
The maximum dose rate in an adjacent primary cooling room is expected to be approximately 5 mrem/hr.
d.
During installation of the iodine and xenon purification and packaging system components, the adjacent cell can be operating, and the dose rate is expected to be approximately 5 mrem/hr.
2.
Confirm that radiation protection surveys, and ALARA work planning practices will be implemented to maintain occupational doses ALARA.