MONTHYEARIR 05000309/20240012024-06-26026 June 2024 Company – Independent Spent Fuel Storage Installation NRC Inspection Reports 07200030/2024001 And05000309/2024001 IR 07200030/20234012023-01-26026 January 2023 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2023401 (Letter Only) IR 07200030/20224012022-10-11011 October 2022 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2022401 IR 05000309/20210012021-10-28028 October 2021 Company - NRC Independent Spent Fuel Storage Installation Inspection Report Nos. 07200030/2021001 and 05000309/2021001 IR 07200030/20204012020-10-21021 October 2020 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2020401 IR 05000309/20180012018-05-30030 May 2018 NRC Independent Spent Fuel Storage Installation Report Nos. 07200030/2018001 and 05000309/2018001, Maine Yankee Atomic Power Company, Wiscasset, Maine Site IR 07200030/20184012018-05-17017 May 2018 IR 07200030-18-401, on May 17, 2018, Maine Yankee - NRC ISFSI Security Inspection Report 07200030/2018401 (Cover Letter Only) IR 05000309/20160012016-05-18018 May 2016 IR 07200030-16-001 and 05000309-16-001 on 4/19/16, Maine Yankee Atomic Power Company, Wiscasset, Me Site IR 07200030/20140012014-05-0606 May 2014 IR 07200030-14-001, on 04/16/14, Independent Spent Fuel Storage Installation, Maine Yankee Atomic Power Company, Wiscasset, Me Site ML1036300172010-12-28028 December 2010 IR 07200030-10-002, on 12/01/10, Maine Yankee Atomic Power Company, Wiscasset, Me (Transmittal Letter) IR 07200030/20100022010-12-28028 December 2010 IR 07200030-10-002, on 12/01/10, Maine Yankee Atomic Power Company, Wiscasset, Me IR 05000309/20080012008-01-28028 January 2008 IR 05000309-08-001, on 06/04/2007 - 07/02/2007 and 11/15/2007 - 12/31/2007, Maine Yankee, Wiscasset, Maine IR 05000309/20050012005-10-0505 October 2005 IR 05000309-05-001 on 02/05/2005 - 07/29/2005 for Maine Yankee Atomic Power Company, Wiscasset, Maine IR 05000309/20050022005-09-30030 September 2005 IR 05000309-05-002 on 06/10/2005 - 09-09/2005, Maine Yankee, Licensee Safety Reviews, Design Changes, and Modifications; Final Status Surveys (Fss); and Radioactive Waste Management Programs IR 05000309/20040022005-02-0101 February 2005 IR 05000309-04-002, on 05/24/2004 - 12/31/2004, Maine Yankee Atomic Power Company, Integrated Inspection IR 05000309/20040012004-08-18018 August 2004 IR 05000309-04-001, on January 12, 2004 - July 29, 2004, Maine Yankee Atomic Power Company IR 05000309/19990011999-06-0707 June 1999 Insp Rept 50-309/99-01 on 990214-0513.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000309/19980051999-03-26026 March 1999 Insp Rept 50-309/98-05 on 981101-990213.Violations Noted & Being Treated as non-cited Violations.Major Areas Inspected: Licensee Operations,Engineering & Plant Support IR 05000309/19980041998-11-27027 November 1998 Insp Rept 50-309/98-04 on 980803-1031.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000306/19960091998-10-0808 October 1998 Discusses Results of Several NRC Insp Repts 50-306/96-09, 50-309/96-10,50-309/96-11,50-309/96-16 & 50-309/97-01, Conducted Between 960715 & 970315,three Investigations Repts 1-95-050,1-96-025 & 1-96-043 & Forwards Notice of Violation IR 05000309/19980031998-09-28028 September 1998 Insp Rept 50-309/98-03 on 980503-0801.No Violations Noted. Major Areas Inspected:Operations,Engineering & Plant Support IR 05000309/19980021998-08-26026 August 1998 Insp Rept 50-309/98-02 on 980317-0506.No Violations Noted. Major Areas Inspected:Water Samples Collected from within & in Vicinity of Wiscasset Landfill IR 05000309/19980011998-05-20020 May 1998 Forwards Insp Rept 50-309/98-01 on 980308-0502 & Nov. Violation Re Poor Implementation of Spent Fuel Pool Foreign Matl Exclusion Program.Vague Procedure & Poor Worker Training Noted IR 05000309/19970091998-05-15015 May 1998 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-309/97-09. Corrective Actions Will Be Examined During Future Insp IR 05000309/19970081997-12-29029 December 1997 Insp Rept 50-309/97-08 on 970908-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Security & Safeguards Activities IR 05000309/19970071997-10-0101 October 1997 Insp Rept 50-309/97-07 on 970728-0907.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000309/19970041997-09-29029 September 1997 Forwards NRC Operator Licensing Exam Rept 50-309/97-04OL (Including Completed & Graded Tests) for Tests Administered on 970609-12 IR 05000309/19970031997-08-28028 August 1997 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-309/97-03 IR 05000309/19970061997-08-14014 August 1997 Insp Rept 50-309/97-06 on 970609-0727.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000309/19960121997-07-31031 July 1997 Ack Receipt of 970107 & 0425 Ltrs Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-309/96-12 & 50-309/96-14.Security Violation Involving Control of Safeguards Info Discussed IR 05000309/19970051997-07-11011 July 1997 Insp Rept 50-309/97-05 on 970427-0608.Violations Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000309/19970011997-05-0202 May 1997 Insp Rept 50-309/97-01 on 970126-0315.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint, Plant Support & Conduct of Security & Safeguards Activities IR 05000309/19960141997-04-0808 April 1997 Errata to Insp Rept 50-309/96-14.Second Bullet on Page 39 Contained Typo IR 05000309/19960161997-02-11011 February 1997 Insp Rept 50-309/96-16 on 961208-970128.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000309/19960131997-01-15015 January 1997 Insp Rept 50-309/96-13 on 961027-1207.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000309/19960091996-11-20020 November 1996 Insp Rept 50-309/96-09 on 960804-0914.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000309/19960111996-11-20020 November 1996 Insp Rept 50-309/96-11 on 960811-0913.Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Surveillance Procedures,Test & Independent Oversight Activities IR 05000309/19960101996-09-20020 September 1996 Insp Rept 50-309/96-10 on 960806-09.Violation Noted But Not Cited.Major Areas Inspected:Engineering Support of Facility & Equipment IR 05000309/19930231993-12-16016 December 1993 Insp Rept 50-309/93-23 on 931012-1119.No Violations Noted. Major Areas Inspected:Plant Activities Including Operations, Maint & Surveillance,Engineering & Technical Support & Overall Plant Support IR 05000309/19930261993-12-14014 December 1993 Exam Rept 50-309/93-26OL on 931115 & 16-18.Exam Results: All Individuals Passed Test & Were Issued Licenses IR 05000309/19930251993-12-0808 December 1993 Insp Rept 50-309/93-25 on 931115-19.No Violations Noted. Major Areas Inspected:Protected Area & Isolation Zone Lighting,Vital Area Physical Barriers & Detection Aids, Protected & Vital Area Acess of Personnel & Power Supply IR 05000309/19930241993-11-24024 November 1993 Insp Rept 50-309/93-24 on 931108-12.Inspectors Found Effective EP Program Implementation in All Areas.Major Areas Inspected:Ep Program Changes,Emergency Facilities,Equipment & Supplies & Organization & Mgt Control IR 05000309/19930221993-10-25025 October 1993 Insp Rept 50-309/93-22 on 930830-1011.Violation Noted But Not Cited.Major Areas Inspected:Operations,Maint & Surveillance,Engineering & Overall Plant Support IR 05000309/19930171993-10-22022 October 1993 Insp Rept 50-309/93-17 on 930917-21.Violations Noted.Major Areas Inspected:Testing of safety-related MOVs Witnessed by Inspector & Safety of Equipment,Matls & Personnel IR 05000309/19930211993-10-19019 October 1993 Insp Rept 50-309/93-21 on 930823-27.No Violations Noted. Major Areas Inspected:Emergency Diesel Generator Load Permissive Relays IR 05000309/19930181993-09-14014 September 1993 Insp Rept 50-309/93-18 on 930728-0829.No Violations Noted. Major Areas Inspected:Operations,Maint/Surveillance, Engineering/Technical Support & Plant Support IR 05000309/19920211993-01-25025 January 1993 Insp Rept 50-309/92-21 on 921120-1231.No Violations Noted. Major Areas Inspected:Plant Operations,Maint & Surveillance Activities,Security,Engineering & Technical Support & Safety Assessment IR 05000309/19920091993-01-25025 January 1993 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-309/92-09 IR 05000309/19930011993-01-15015 January 1993 Insp Rept 50-309/93-01 on 930104-08.No Violations Noted. Major Areas Inspected:Mgt Organization,Radiation Control During Normal Operations,Alara & Implementation of Programs IR 05000309/19920801992-12-23023 December 1992 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp 50-309/92-80.Actions Re Failure to Perform Review of Mod of Power Supply for App R DG Fuel Oil Day Tank Level Alarm Sensor Will Be Examined 2024-06-26
[Table view] Category:Letter
MONTHYEARIR 05000309/20240012024-06-26026 June 2024 Company – Independent Spent Fuel Storage Installation NRC Inspection Reports 07200030/2024001 And05000309/2024001 ML24124A1372024-04-30030 April 2024 Independent Spent Fuel Storage Installation - 2023 Individual Monitoring NRC Form 5 Report ML24117A0602024-04-23023 April 2024 Independent Spent Fuel Storage Installation - Annual Radioactive Effluent Release Report, Annual Radiological Environmental Operating Report, and Changes to the Off-Site Dose Calculation Manual for 2023 ML24094A0602024-03-28028 March 2024 Independent Spent Fuel Storage Installation, Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for the Maine Yankee Independent Spent Fuel Storage Installation ML24074A3822024-03-11011 March 2024 Independent Spent Fuel Storage Installation, Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML24074A3812024-03-11011 March 2024 Independent Spent Fuel Storage Installation, Decommissioning Funding Assurance Status Report NG-24-0001, 2024 Annual Decommissioning and Spent Fuel Management Funding Status Report and Independent Spent Fuel Storage Installation (ISFSI) Decommissioning Financial Assurance Update2024-03-0606 March 2024 2024 Annual Decommissioning and Spent Fuel Management Funding Status Report and Independent Spent Fuel Storage Installation (ISFSI) Decommissioning Financial Assurance Update ML23286A3262024-02-29029 February 2024 Issuance of Exemption for Maine Yankee Atomic Power Company Regarding Maine Yankee Independent Spent Fuel Storage Installation ML24025A0392024-01-12012 January 2024 Independent Spent Fuel Storage Installation, Property Insurance Coverage ML23342A1112024-01-0909 January 2024 Company - Independent Spent Fuel Storage Installation Security Inspection Plan ML23117A0452023-04-25025 April 2023 Independent Spent Fuel Storage Installation, Annual Radioactive Effluent Release Report, Annual Radiological Environmental Operating Report, and Changes to the Off-Site Dose Calculation Manual for 2022 ML23113A0052023-03-31031 March 2023 Request for Exemption from 10 CFR 50.82 10 CFR 50.75 for the Maine Yankee Independent Spent Fuel Storage Installation NG-23-0001, 2023 Annual Decommissioning and Spent Fuel Management Funding Status Report2023-03-27027 March 2023 2023 Annual Decommissioning and Spent Fuel Management Funding Status Report ML23068A0112023-03-0606 March 2023 Independent Spent Fuel Storage Installation, Decommissioning Funding Assurance Status Report ML23068A0132023-03-0606 March 2023 Independent Spent Fuel Storage Installation, Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML22340A4622023-02-24024 February 2023 Closeout Letter to Maine Yankee Atomic Power Company Regarding 2018 and 2021 Updated DFPs for Maine Yankee ISFSI IR 07200030/20234012023-01-26026 January 2023 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2023401 (Letter Only) ML23026A0802023-01-17017 January 2023 Company - Property Insurance Coverage IR 07200030/20224012022-10-11011 October 2022 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2022401 ML22216A0682022-07-28028 July 2022 Independent Spent Fuel Storage Installation, Supplemental Information for the Three-Year Update to the Independent Spent Fuel Storage Installation Decommissioning Funding Plan ML22088A0212022-04-0101 April 2022 Independent Spent Fuel Storage Installation, 10 CFR 72.48 Biennial Report ML22088A0182022-04-0101 April 2022 Independent Spent Fuel Storage Installation, 10 CFR 50.59 Biennial Report NG-22-0041, And Independent Spent Fuel Storage Installation, 2022 Annual Decommissioning and Spent Fuel Management Funding Status Report2022-03-31031 March 2022 And Independent Spent Fuel Storage Installation, 2022 Annual Decommissioning and Spent Fuel Management Funding Status Report ML22088A0122022-03-14014 March 2022 Independent Spent Fuel Storage Installation - Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML22088A0162022-03-14014 March 2022 Independent Spent Fuel Storage Installation, Decommissioning Funding Assurance Status Report ML22011A1332022-01-31031 January 2022 Company - Independent Spent Fuel Storage Installation Security Inspection Plan ML22045A0662022-01-20020 January 2022 Independent Spent Fuel Storage Installation - Property Insurance Coverage ML22045A0652022-01-20020 January 2022 Independent Spent Fuel Storage Installation, Nuclear Liability Insurance Coverage ML21362A1592021-12-10010 December 2021 Independent Spent Fuel Storage Installation, Three-Year Update to the Independent Spent Fuel Storage Installation Decommissioning Funding Plan IR 05000309/20210012021-10-28028 October 2021 Company - NRC Independent Spent Fuel Storage Installation Inspection Report Nos. 07200030/2021001 and 05000309/2021001 NG-21-0006, 2021 Annual Decommissioning and Spent Fuel Management Funding Status Report2021-03-31031 March 2021 2021 Annual Decommissioning and Spent Fuel Management Funding Status Report ML21077A1672021-03-0202 March 2021 Independent Spent Fuel Storage Installation - Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML21105A7392021-03-0202 March 2021 Independent Spent Fuel Storage Installation - Decommissioning Funding Assurance Status Report ML21042B5932021-01-27027 January 2021 Independent Spent Fuel Storage Installation, Property Insurance Coverage ML21042B5942021-01-27027 January 2021 Independent Spent Fuel Storage Installation, Nuclear Liability Insurance Coverage ML21012A3992021-01-13013 January 2021 Company - Independent Spent Fuel Storage Installation Security Inspection Plan ML21042B8962021-01-11011 January 2021 Independent Spent Fuel Storage Installation, Biennial Update of the Defueled Safety Analysis Report ML21050A2302021-01-11011 January 2021 Independent Spent Fuel Storage Installation - Formal Announcement of New ISFSI Manager IR 07200030/20204012020-10-21021 October 2020 Company - NRC Independent Spent Fuel Storage Security Inspection Report No. 07200030/2020401 ML20136A3372020-04-22022 April 2020 Independent Spent Fuel Storage Installation, Annual Radioactive Effluent Release Report, Annual Radiological Environmental Operating Report, and Changes to the Off-Site Dose Calculation Manual for 2019 ML20101H9312020-04-0101 April 2020 Independent Spent Fuel Storage Installation - 10 CFR 50.59 Biennial Report ML20097B6692020-03-19019 March 2020 Independent Spent Fuel Storage Installation, Funding Status Report for Managing Irradiated Fuel and GTCC Waste ML20087J6772020-03-11011 March 2020 Independent Spent Fuel Storage Installation - Decommissioning Funding Assurance Status Report ML20015A5492020-01-15015 January 2020 Company - Independent Spent Fuel Storage Installation Security Inspection Plan ML19241A4582019-08-29029 August 2019 Letter to T. Matthews Maine Yankee Atomic Power Company - Threshold Determination That NRC Consent Is Not Required in Connection with Acquisition of Emera Maine by Enmaz Corporation ML19182A0322019-07-0505 July 2019 Letter to J. Brown Maine Yankee Atomic Power Company Exemption Request from Certain Requirements of 10 CFR 72.214 for the ISFSI ML19182A0402019-07-0505 July 2019 Letter to P. Dostie Maine Yankee Atomic Power Company Exemption Request from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for the ISFSI ML19113A1032019-04-23023 April 2019 Request for NRC Threshold Determination That NRC Consent Is Not Required in Connection with Acquisition of Emera Maine by Enmax Corporation ML19127A2892019-04-16016 April 2019 Independent Spent Fuel Storage Installation, Submittal of Annual Radioactive Effluent Release Report, Annual Radiological Environmental Operating Report, and Changes to the Off-Site Dose Calculation Manual for 2018 ML19112A0242019-04-11011 April 2019 Independent Spent Fuel Storage Installation, Reference Correction - Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 2024-06-26
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COM MISSION
REGION I
2100 RENAISSANCE BLVD.
KING OF PRUSSIA, PA 19406-2 713
October 28, 2021 Dan Laing ISFSI Manager Maine Yankee Atomic Power Company 321 Old Ferry Road Wis c ass et, ME 04578
SUBJECT: MAINE YANKEE ATOMIC POWER COMPANY - INDEPENDENT SPENT FUEL STORAGE INSTALLATION NRC INSPECTION REPORT NOS.
07200 030 /202 1001 AND 05000 309/20 2100 1
Dear Mr. Laing:
On September 27, 2021, the U.S. Nuclear Regulatory Commission (NRC) conducted a safety ins pec tion at the Maine Yankee Atomic Power Company (Maine Yankee) Indepe ndent Spent Fuel Storage Installation (ISFSI). The inspection examined activities under your license as they relate to safety and compliance with the Commissions regulations and conditions of your license. The inspection consisted of observations by the inspector, interviews with s i t e personnel, and a review of procedures and recor ds. The results of the inspection were discussed with Mr. Wayne Norton, you, and members of your staff during a phone call on October 6, 2021. The enclosed report presents the results of this inspection.
Within the scope of this inspection, no violations were identified.
In accordance with 10 CFR 2.390 of the NRCs "Rules of Practice," a copy of this letter, its enclosure, and your response, if you choose to provide one, will be made available electronically for public inspection in the NRC Public Document Room or from the NRC document system (ADAMS),
accessible from the NRC Web site at http://www.nrc.gov/reading-rm/ad am s.html. To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be made available to the Public without redaction.
D. Laing 2
No reply to this letter is required. Please contact Ory s ia Mas nyk Bailey at 864-4 27-1 032 if you have any questions regarding this matter.
Sincerely, Anthony Dimitriadis, Chief Decommissioning, ISFSI and Reactor HP Branch Division of Radiological Safety and Security
Doc k et Nos. 07200030, 050003 09 License Nos. SFGL-14, DPR-36
Enclosures :
Inspection Report Nos. 07200030 /20 2100 1 and 05000309/20 2100 1
cc w/enclosure: State of Maine MAINE YANKEE ATOMIC POWER COMPAN Y - NRC INDEPENDENT SPENT FUEL STORAGE INSTALLATION INSPECTION REPORT NOS. 07200030/2021001 AND 050003 09/2021001 DATED October 28, 2021.
DOCUMENT NAME: https://usnrc.sharepoint.com/:w:/r/teams/Region-I-D e commissioning-Branch/_layouts/15/Doc.aspx?sourcedoc=%7B7713E269-5776-479 2-A4E F-BE50CC662 558%7D&file=MaineYa nkee.2021 001.docx&action=default&mobileredir ect=true SUNSI Review Complete: OMasnykBailey After declaring this document An Official Agency Record it will be released to the Public.
To receive a copy of this document, indicate in the box: C = Copy w/o attach/encl E = Copy w/ attach/encl N = No copy ML21300A066
__ SUNSI Reviewx Non-Sensitive x Publiclyvailab Sensitive n -Publicvailab
FICE :DNMS :DNMS ME OMkBl /B ADimitriadis/ad
DATE 10/26/2021 10/28/2021 OFFICIAL RECORD COPY U.S. N UCL EAR RE GUL AT ORY C OMMISSI ON RE GIO N I
INSPECTION REPORT
Inspection Nos. 07200 030 /202 1001 a nd 0500 0309/2 0210 01
Doc k et Nos. 07200 030 and 0 5000309
License Nos. SFGL-14 and DPR-36
Licensee: Maine Yankee Atomic Power Company
Location: Wis c ass et. ME
Inspection Dates: September 27, 2021
Inspector: Orysia Masnyk Bailey, Health Physicist Decommissioning, ISFSI and Reactor Health Physics Branch Division of Radiological Safety and Security
Approved By: Anthony Dimitriadis, Chief Decommissioning, ISFSI and Reactor Health Physics Branch Division of Radiological Safety and Security EXECUTIVE SUMMARY
Maine Yankee Atomic Power Company Inspection Report Nos. 07200030/ 2021001 and 05000309/2021001
An announc ed routi ne inspecti on of t he Mai ne Yank ee Atomic Power Company (Mai ne Yankee)
ISFSI was complet ed on October 6, 2021. A n on-site inspecti on was perform ed on September 27, 2021. T he inspecti on incl uded a review of radiati on protection, fir e protection, emergency preparedness, surveillance, maintenance, environmental monitoring, training, quality assurance (QA), and correctiv e acti on programs. T he inspecti on consist ed of observations by the inspector, interviews with Connecticut Yank ee personnel, and a review of records and procedures. T he NRC's program for overseei ng t he saf e operati on of an ISFSI is descri bed in Inspection Manual Chapter (IMC) 269 0, Inspecti on Program for Stor age of Spent Reactor Fuel and Reactor Relate d Greater -Than-Class C W aste at Independent Spent Fuel Storage Installations and for 10 CFR Part 71 Transportati on Packagings."
Based on t he results of this inspection, no findings of significanc e wer e identified.
ii REPORT DET AILS
1. Inspection Scope, Observations, and Conclusion
a. Inspection Scope
The inspector assessed whether Maine Yankee personn el were op erating and maintaining ISFSI programs at an away-from-re actor (AFR) ISFSI in conformance with the commitments and requirements contained in the Final Safety Analysis Report (FSAR), Safety Evaluation Report (SER), Certificate of Compliance (CoC), Technical Specifications (TS), Quality Assurance (QA) progr am, Maine Yankee procedures, and 10 CFR Part 72.
AFR ISFSI activities, located at sites where loading oper ations have been completed, are essentially passive operating facilities. The inspectors review was directed toward confirming the ongoing ade quacy of the radiation protection, fire protection, emergency prepa redn ess, surveillance, maintenance, environmental monitoring, training, QA, and corrective action programs.
The inspector observed activities, interviewed site personnel, and reviewe d procedur es and records. The inspector also reviewed changes made to Maine Yankees programs and procedu res since the last inspection to determine if changes were consistent with the license or CoC and if such changes reduced the effectiveness of the program.
b. Observations and Findings
The inspector determined that Maine Yankees plans and preparations for controlling radiological activities were effective at meeting 10 CFR Part 20 requireme nts. The inspector also verified that special nuclear material (SNM) stored at the ISFSI was prope rly accounted for. Dosimetry records and environmental reports wer e found to be complete, and all employee exposures were below the regul at ory dose limits, and dose to members of the public at the nearest accessible location to the ISFSI were within limits as prescribed by 10 CFR 72.104.
The inspector verified Maine Yankees emergency preparedness progr am was properly coordinated with the appr opriate offsite support groups, agencies, and local law enforcement agencies (LLEAs). The inspector also verified the emergency call list was current and checked periodically for accuracy and all revisions to the emergency plan had been submitted to the NRC and reviewe d by the Office of Nuclear Security and Incident Response (NSIR).
The inspector verified that daily temperature monitoring of the vertical concrete casks (VCCs) was performed by Maine Yankee person nel in accordance with surveillance requir ements in the TS and that Maine Yankees procedures contain back up plans if the primary surveillance method became unavailable. The inspector also verified that transient combustibles were not being stored on the ISFSI pad or in the vicinity of the VCCs and confirmed procedur es were in place to control entry onto the ISFSI pad.
The inspector determined Maine Yankee has a training prog ram which consists of classroom instruction, on-the-job training, and various drills, as well as shift turnover briefings by supervisors and that refresher training was given on a regula r basis. The inspector verified all employees had been trained an d qualified to perform their assigned ISFSI related duties.
The inspector determined that issues were entered into the corrective action prog ram, prioritized, and evaluated commensurate with their safety significance, and corrective actions were implemented to address identified issues and were tracked to closure. The inspector verified the QA program evaluated changes in the ISFSI progra m to ensure that any changes that were implemented would n ot decrease the overall effectiveness of the program. The inspector also determined the Maine Yankees 10 CFR 72.212 evaluation report had b een app rop riately updated.
c. Conclusion
Based on the results of this inspection, no findings of significance were identified.
2. Exit Meeting
On October 6, 2021, the inspector presented the inspection results to Mr. Wayne Norton, President, Maine Yankee Atomic Power Compa ny, who acknowledged the inspection results. No proprietary information was retained by the inspector or documented in this report.
ATT ACHMENT
PART IAL LIST OF PERSONS CONT ACTED
- W. Norton, President and CEO
- D. Laing, Maine Yankee ISFSI Manager J. Bouras s a, Radiation Protection Manager
- S. Day, Licensing Representative, 3 Yankee Companies
- N. Fales, Aging Canister Program Manage r, 3 Yankee Companies
- J. Fay, General Cou nsel, 3 Yankee Companies
- S. Hemingway, Assistant Director of Operations
- J. Laughney, QA Representative, 3 Yankee Companies
- J, Macdonald, Yankee Rowe ISFSI Manager
- M. Marston, Director of Operations
- P. Plante, Cask Relicensing Project Manager, 3 Yankee Companies P. Woodhams, Operations Specialist
- Pres ent at v irtual ex it meeting c onduc ted on October 6, 2021
ITEMS OPEN OR CLOSED
None
PRIMARY DOCUMENT S REVIEWED
Audits and Reports
Annual Radioactive Effluent Release Reports, Annual Radiological Environmental Operating Report, and Ch anges to the Off-Site Dose Calculation Manual, 2018-2021 Special Nuclear Material Inventories 2018-202 0 2019 Ne utron Survey ISFSI-19- 086 Documentation of the Completion of the Radiological Assessment of the Vertical Concrete Cask Cracks, August 20, 2019 Personnel Dose Rep orts 2018-20 20 General Are a Surveys 2018-2020 Personnel Training a nd Qualification Records Quality Assurance Assessments and Status Reports 2018-2 020 EP Drills and Assessments 2018-2020 VCC and Pad Inspections 2018-2020
Procedures
EF3, Rev. 5, Special Nuclear Material and Greater than Cl ass C Waste Control, Accountability, and Rep orting Progr am Emergency Plan, Rev. 8 EO-1, Rev. 10, Emergency Plan Implementation FP-1, Rev. 10, Fire Protection Program FP-2, Rev. 9, Fire Hazards Analysis
Procedures (Co ntd)
FP-3, Rev. 10, Fire Fighting Pre-Plans FP-4, Rev. 6, Fires and Fire Alarms FP-7, Rev. 3, ISFSI Fire Protection System OP-1, Rev. 9, Concrete Cask Heat Removal System Surveillance Plan RP-1, Rev. 5, Conduct of Radiation Protection RP-2, Rev. 16, Radiological Surveys and Postings RP-3, Rev. 10, Radiological Environmental Monitoring Program (REMP)
RP-4, Rev. 7, Personnel Radiation Monitoring RP-3, Rev. 9, Radiation Work Permits RP-6, Rev. 4, ISFSI Source Control Program
INSPECT ION PROCEDURES USED IP 60858, AWAY-FROM-REACTOR INDEPENDENT STORAGE INSTALLATION INSPECTION GUIDANCE
LIST OF ACRONYMS USED AFR Away from Reactor CFR Code of Feder al Regulations CoC Certificate of Compliance DRSS Division of Radiological Safety and Safeguards FSAR Final Safety Analysis Report HP Health Physics IP Inspection Procedure ISFSI Independ ent Spent Fuel Storage Facility LLEA Local Law Enforcement Agency NRC Nuclear reg ulatory Commission NSIR Office of Nuclear Security and Incident Response QA Quality Assurance SER Safety Ev aluation Report SNM Special Nuclear Material TS Technical Specifications VCC Vertical Concrete Cask
4