MONTHYEARML24222A8592024-08-0909 August 2024 International - HI-STORM 100 Multipurpose Canister Storage System Amendment 19 Request AEP-NRC-2024-62, Unit 2 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Storage Cask2024-08-0808 August 2024 Unit 2 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Storage Cask SVP-24-048, Registration of Use of Casks to Store Spent Fuel2024-07-31031 July 2024 Registration of Use of Casks to Store Spent Fuel ML24178A4312024-07-29029 July 2024 Issuance of Certificate of Compliance No. 1014, Amendment No. 16 for the HI-STORM 100 Cask System, Cover Letter AEP-NRC-2024-56, Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask2024-07-0808 July 2024 Unit 2, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask NL-24-0199, Request for Specific Exemption2024-06-25025 June 2024 Request for Specific Exemption SVP-24-040, Registration of Use of Casks to Store Spent Fuel2024-06-25025 June 2024 Registration of Use of Casks to Store Spent Fuel NL-24-0243, Registration of Spent Fuel Cask Use2024-06-18018 June 2024 Registration of Spent Fuel Cask Use ML24183A2752024-05-30030 May 2024 Registration of Use of Casks to Store Spent Fuel ML24145A0432024-05-23023 May 2024 Registration of Use of Casks to Store Spent Fuel 10 CFR 72.212 SVPLTR 24-0019, Registration of Use of Casks to Store Spent Fuel2024-05-23023 May 2024 Registration of Use of Casks to Store Spent Fuel ML24143A0752024-05-22022 May 2024 Re. Ginna Nuclear Power Plant and Independent Spent Fuel Storage Installation (ISFSI) Registration for Use of General License ISFSI Casks NL-24-0197, Registration of Spent Fuel Cask Use2024-05-20020 May 2024 Registration of Spent Fuel Cask Use ML24135A3212024-05-14014 May 2024 Annual Radioactive Effluent Release Report, January 1 Through December 31, 2023 CP-202400153, (Cpnpp), Registration of Dry Spent Fuel Storage Canisters2024-04-29029 April 2024 (Cpnpp), Registration of Dry Spent Fuel Storage Canisters SVP-24-028, Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report2024-04-26026 April 2024 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report ML24109A2072024-04-18018 April 2024 International - Submittal of HI-STORM Final Safety Analysis Report Update BYRON 2024-0021, Registration of Use of Cask to Store Spent Fuel2024-04-11011 April 2024 Registration of Use of Cask to Store Spent Fuel BYRON 2024-0019, Registration of Use of Cask to Store Spent Fuel2024-03-28028 March 2024 Registration of Use of Cask to Store Spent Fuel RS-24-020, Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for Quad Cities Nuclear Power Station - Holtec MPC-68MCBS2024-03-15015 March 2024 Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 for Quad Cities Nuclear Power Station - Holtec MPC-68MCBS LR-N24-0022, Spent Fuel Cask Registration2024-02-29029 February 2024 Spent Fuel Cask Registration ML24046A2552024-02-15015 February 2024 International, Submittal of Supplement to RAI Responses on HI-STORM 100 Amendment 18 ML24016A1902024-01-30030 January 2024 International, Inc. - Notice of Violation; the U.S. Nuclear Regulatory Commission Inspection Report 07201014/2022201 ML24018A1992024-01-18018 January 2024 International, Administrative Change to HI-2200343-A ML23363A0312024-01-0404 January 2024 Application for HI-STORM 100 Cask System, Amendment No. 19 - Acknowledgement of Withdrawal and Notification of the U.S. Nuclear Regulatory Commission Staff Efforts Closure ML23355A0842023-12-21021 December 2023 International, Withdrawal of HI-STORM I00 Multipurpose Canister Storage System Amendment ML23324A0952023-12-0606 December 2023 Amendment No. 19 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multi-purpose Canister Storage System - Request for Additional Information ML23328A0052023-12-0505 December 2023 Issuance of Renewed Certificate of Compliance No. 1014, Amendment No. 17 for the Hi-Storm 100 Cask System (Cac/Epid 001028/L-2021-LLA-0140) ML23338A3052023-12-0404 December 2023 International, Submittal of Supplement to RAI Responses on HI-STORM 100 Amendment 18 ML23334A1912023-11-30030 November 2023 International, Submittal of Topical Report HI-2210161-A Version ML23321A2172023-11-17017 November 2023 International, Responses to NRC Questions Form EA-23-044 Pre-Decisional Enforcement Conference JAFP-23-0063, Registration of Spent Fuel Cask Use2023-11-13013 November 2023 Registration of Spent Fuel Cask Use ML23310A0362023-11-0909 November 2023 International, Inc. - U.S. Nuclear Regulatory Commission Inspection Report 07201014/2023201 ML23283A1262023-11-0202 November 2023 Letter - Second Request for Additional Information - HI-STORM 100 Amd 18 ML23289A1582023-10-16016 October 2023 Decommissioning International - Registration of Spent Fuel Casks and Notification of Permanent Removal of All Indian Point Unit 3 Spent Fuel Assemblies from the Spent Fuel Pit ML23270A0082023-09-27027 September 2023 Registration of Spent Fuel Casks ML23263B1232023-09-20020 September 2023 HI-STORM 100 Amendment 16 Responses to Second Round Requests for Additional Information ML23234A1572023-09-14014 September 2023 Letter to Holtec International Final Safety Evaluation for Hi-2210161, Revision No. 4, Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems ML23145A1752023-09-12012 September 2023 NRC Choice Letter to Holtec International with Attached Safety Inspection Report, IR 72-1014/2022-201, December 12-15, 2022, Inspection of Holtec International in Camden, New Jersey (Docket Nos.: 72-1014, 72-1032) ML23251A2512023-09-0808 September 2023 International, Submittal of Supplement to RAI Responses on HI-STORM 100 Amendment 18 ML23250A0812023-09-0707 September 2023 Registration of Spent Fuel Casks ML23230B1582023-08-28028 August 2023 Amendment 16 to Certificate of Compliance 1014 for HI-STORM 100 Multipurpose Canister Storage System Request for Additional Information Second Round NL-23-0620, ISFSI, and Edwin I. Hatch Nuclear Plant ISFSI, Registration of Spent Fuel Cask Use2023-08-0303 August 2023 ISFSI, and Edwin I. Hatch Nuclear Plant ISFSI, Registration of Spent Fuel Cask Use ML23135A7582023-07-20020 July 2023 Letter to Holtec - Draft SE for HI-2210161, Revision No. 4, Topical Report ML23200A0422023-07-19019 July 2023 Registration of Spent Fuel Casks ML23195A0382023-07-14014 July 2023 U.S. Nuclear Regulatory Commission Inspection Report No. 72-1014/2023-201 NL-23-0566, ISFSI and Edwin I. Hatch Nuclear Plant ISFSI - Registration of Spent Fuel Cask Use2023-07-13013 July 2023 ISFSI and Edwin I. Hatch Nuclear Plant ISFSI - Registration of Spent Fuel Cask Use ML23068A3852023-06-29029 June 2023 1. Transmittal Letter, Renewal of CoC No. 1014, HI-STORM 100 Cask System ML23163A1402023-06-23023 June 2023 Acceptance Review of Request for Amendment No. 19 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System SVPLTR 23-0021, Registration of Use of Casks to Store Spent Fuel2023-06-20020 June 2023 Registration of Use of Casks to Store Spent Fuel 2024-08-09
[Table view] |
Text
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 August 9, 2021 Shana Helton, Director Division of Fuel Management Office of Nuclear Material Safety and Safeguards ATTN:
Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No. 72-1014, Certificate of Compliance (CoC) No. 1014
Subject:
Transmittal of Final Safety Analysis Report Update for the HI-STORM 100 Storage System per 10 CFR 72.248
Reference:
[1] Issuance of Certificate of Compliance No. 1014, Amendment No. 15 for the HI-STORM 100 Multipurpose Canister Storage System (Docket No. 72-1014, CAC No. 001028, EPID: L-2019-LLA-0059), letter dated May 13, 2021, from J. McKirgan (NRC) to B. Seawright (Holtec).
[2] USNRC Docket No. 72-1014, HI-STORM 100 Certificate of Compliance 1014, HI-STORM Final Safety Analysis Report Update, letter dated June 12, 2020, from J. Tomlinson (Holtec) to A. Kock (NRC).
Dear Ms. Helton:
In accordance with 10 CFR 72.248, Holtec International herewith submits Holtec Report No.
2002444, Revision 22 of the Final Safety Analysis Report (FSAR) for the HI-STORM 100 Storage System. This revision includes the effects of all changes to the cask design or procedures that have received prior NRC review and approval through Amendment 15 to the HI-STORM 100 CoC [1]. This FSAR also includes the effects of changes to the cask design or procedures made pursuant to 10 CFR 72.48 and Engineering Change Orders (ECOs) since FSAR Revision 20 [2]. Note that HI-STORM 100 FSAR Revision 22 includes a Summary of Revision and all changes included in the FSAR text and tables are indicated with revision bars in the right margin and Rev. 22 in the lower right corner of the page.
Document ID: 5014930 Page 1 of 2
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Attachments 1 and 2 to this letter contain the proprietary and non-proprietary versions of HI-STORM 100 FSAR Revision 22, respectively. As Attachment 1 is considered proprietary, an affidavit requesting that this information be withheld from public disclosure in accordance with 10 CFR 2.390 is contained in Attachment 3.
If you have any questions, then please contact me at (856)-797-0900 ext. 3848.
Sincerely, Christopher OMullane Licensing Engineer Holtec International cc: (letter only, no attachment, via email)
Mr. John McKirgan (NRC)
Ms. Kimberly Manzione (Holtec)
Attachments : HI-2002444 HI-STORM 100 FSAR, Rev. 22 (Holtec Proprietary Information) : HI-2002444 HI-STORM 100 FSAR, Rev. 22 (Non-Proprietary Version) : Affidavit Pursuant to 10 CFR 2.390 Document ID: 5014930 Page 2 of 2