_ _ - _ - _ _ _ _ _ _ - - _ _

'\\

Docket Nos:

50 443 DISTRIBUTION 50 444 FEB 2 21985 CENTRAL FILES RAB READING FILE MEMORANDUM FOR: Thomas M. Novak, Assistant Director AD:RP FILE for Licensing, DL FJCONGEL MLAMASTRA FROM:

Daniel R. Muller, Assistant Director OLYNCH for Radiation Protection, DSI

SUBJECT:

SEABROOK STATION - UNITS 1 AND 2 ALTERNATIVE PIPE BREAK DESIGN CONSIDERATIONS - REQUEST FOR AN EXEMPTION.T0 GDC-4 The Radiological Assessment Branch has reviewed the submittal of Seabrook Station Unit 1 and 2 with respect to their alternative pipe break design considerations. Our review considered the effects of the prcposed GDC-4 exemption on occupational exposure.

It is our conclusion, with'the respect to occupational exposure, that there is a significant benefit in notaddinh the additional protective structures, and RAB has no objections to granting Seabrook an exemption. Attached are our SER and SALP inputs."

l This review was performed by M.Lamastra, RPS/RAB.

C:.a1 sincd by W!NC.M_Y_le(j Daniel R. Muller, Assistant Director for Radiation Protection Division of Systems Integration

Attachment:

As stated cc:

R. Bernero G. Knighton V. Nerses l

r

/

IFC :DSI:RAB

DSI:RA
DSI:RAB Q SI:AD:RP AME :MLamas ra:cm:0
FJCongel ' J :DR p r LATE :2/19/85
2/M /85
2/tt/85
2/ "/85 0FFICIAL RECORD COPY Y $d118%) M

^

urs