ML20237B467

From kanterella
Jump to navigation Jump to search
Summary of 871117 & 18 Meetings W/Util at Plant Site Re Licensee Inservice Testing Program.Licensee Committed to Resubmit Inservice Testing Program in May 1988,pending Closure of Open Items by 880101.List of Attendees Encl
ML20237B467
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 12/09/1987
From: Dick G
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20237B468 List:
References
NUDOCS 8712160283
Download: ML20237B467 (3)


Text

..

December 9,1987 L-Socket No. 50-313 LICENSEE: Arkansas Power and Light Company  ;

FACILITY: Arkansas Nuclear One, Unit 1 (ANO-1) i

SUBJECT:

SUMMARY

OF MEETING ON ANO-1 INSERVICE TESTING (IST) PROGRAM On November 17 and 18, a meeting was held at ANO-1 to discuss the licensee's IST program. Attendees included representatives from EG&G Idaho as well as from the licensee's and NRC staff. A list of attendees is included in Enclosure 1.

The IST program had been submitted to the staff on February 20, 1985. It had undergone an initial review and questions that were generated were sent to the licensee in June 1987. The licensee was requested to prepare draft nswers which were to be used as the basis for discussions with the staff. During the November meeting, each question was discussed, clarified if necessary, and a response noted. The discussions which are documented in Enclosure 2, resulted in 13 Open Items for the licensee and 6 Open Items for the staff.

As a result of the discussions, it was agreed that the licensee would resubmit 4ts IST program. During a telephone call on December 3, 1987, it was agreed that the licensee would resubmit the IST program in May 1988 pending closure of the staff open items by January 1, 1988.

N George F. Dick, Jr., Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, V and Special Projects

Enclosures:

As stated cc w/ enclosures:

See next page DISTRIBUTION Docket File NRC PDR Local PDR PD4 Reading J. Calvo G. Dick OGC-Bethesda E. Jordan J. Partlow A. Masciantonio B. Johnson ACRS (10)

PD4 Plant File Ah4/PM PD4/D JM 010 Dick:sr JCalvo 12/Cy/87 12/'/ /87 p

e7121%$$$

PDR P

v; > w-i

~

Mr. G. Campbell 4 Arkansas Power & Light Company Arkansas Nuclear One, Unit 1 -l cc:

l Mr. J. Ted Enos,. Manager

! Nuclear Engineering and Licensing Arkansas-Power & Light Company P. 0.. Box'551 l Little Rock,-Arkansas 72203 L Mr. James M. Levine, Director Site Nuclear Operations Arkansas Nuclear One P. 0.-Box 608 Russellville, Arkansas 72801 Mr. Nicholas S. Reynolds Bishop,.Liberman, Cook, Purcell & Reynolds 1200 Seventeenth Street, N.W.

Washington, D.C. 20036 Mr. Robert B. Borsum Babcock & Wilcox-Nuclear Power Generation Division i Suite'220, 7910 Woodmont Avenue l- Bethesda, Maryland .20814

! Resident Inspector U.S. Nuclear Regulatory Commissi6n l- 1 Nuclear Plant Road Russellville, Arkansas 72801 i

Regicnal Administrator, Region IV-l U.S. Nuclear Regulatory Commission ,

Office of Executive Director {

for Operations i 611 Ryan Plaza Drive, Suite 1000 j l

Arlington, Texas 76011 l J

L 'Mr. Frank Wilson, Director l Division of Environmental Health Protection Department of Health

(. Arkansas Department of Health L 4815 West Markhan Street

! Little Pock, Arkansas 72201 Honorable Williar.Abernathy County Judge of Pope County Pope County Courthouse Russellville, Arkansas 72801 L___ _ -__ -_

' s

%: g l:

I -

ENCLOSURE 1 l- ATTENDEES ANO-1 IST MEETING NOVEMBER 17 AND 18, 1987 l

NAME ORGANIZATION R. Scott Hartley EG&G Idaho clair Ransom EG&G Idaho N. Bradley Stockton EG&G Idaho Sandy McGregor AP&L Charles Zimerman AP&L Alan Cox- AP&L

, David Crabtree AP&L Rick Lane AP&L Robert McWilliams AP&L George Woerner AP&L Don Lomax AP&L Armando Masciantonio NRC Bill Johnson NRC George Dick NRC I

I

_ _ _ _ _ _ _ _ _ _ - -