Text
_
7.
2 N0e ; 5 1998
" M0?ANDUM FOR:
Charles E. Rossi. Director Division of Operational Events Assessment io Wayne D. Lanning. Chief Ever,ts Assessment Branch 01visten of Operational Events Assessment
,eCT:
THE OPERATING REACTORS EVENTS MEETING November 15, 1988 - MEETlHG 88-45 On November 15, 1988, an Operating Reactors Events mee+.ing (88-45) was held to brief senior managers from NRR. AE00. OSP. RES. Commission Staff, and Regional Offices on events which occurred since our last reeting on November 8, 1988.
The list of attendees is included as Enclosure 1.
~'e event. discussed and the significant elements of these events are presented
.o Enclosure 2. presents a summary of reactor scrams. Two significant events were identified for input to NRC's performance indicator 04'isttml 82szw4 tif program.
WaYo* D. Inening Wayne D. Lanning. Chief f
Events Assessment Branch t
Division of Operational Events Assessment
Enclosures:
As stated cc w/ Encl.:
See Next Page 015TRIBUT10N gg M
Central File F
8) 1 7jh EAB Reading File dg. f f)'@, I Circulating Copy. EAB Staff i
&q q
), )) g
/
MLReardon, EAB b
yb' 00udinot. EAB eb LKilgore. SECY PDR
)9 0FC
- EA8 0
- C:EA 00EA :
r.:------------:------------:------------:------ -----:-----------
NAME :Mt.Reardon
- W g
DATE :11/ct/ /88
]
,o cc:
T. Murley, 12G-18 G. Dick 130-18 F. Miraglia.12G-18 C. Harbuck. 13E-4 J. Sniezek. 12G-18 S. Sands 130-1 E. Jordan. AE03 J. Stevens 130-1 J. Taylor. 17G-13
- 0. Muller, 130-3 E. Beckjord NL-007 J. Calvo 130-17 W. Russell. R1 M. Ernst. Rll B. Davis. Rill R. D. Martin. RIV J. B. Martin RV W. Kane. RI L. Reyes, Ril E. Greenman. Rill r
L. Callan. RIV D. Kirsch RV S. Varga. 14E-4
- 0. Crutchfield. 13A-2 5!. Boger. 14A-2 G. Lainas 14H-3 G. Holahan. 13H-4 L. Shao. 8E-2 J. Particw 70-24
[
B. Grimes. 9A-2 F. Congel, 10E-4 E. Weiss. AE00 T. Martin. E00 J. Guttmann. SECY A. Thadani. 7E-4 S. Rubin. AE00 J. Forsyth. INPO R. Barrett. 10E-2 i
M. Harper MNBB 4210 L
k t
a s
e
3e nevq
/
4-UNITED STATES 8
- ~k' NUCLEAR REGULATORY COMMISSION
^
p p
WASHING TON, D. C. 20555
- o.... ys?
NOV 2 6 Nng HEMORAN00M FOR:
Charles E. Rossi. Director Division of Operational Events Assessment FROM:
Wayne 0. Lanning. Chief Events Assessment Branch Division of Operational Events Assessment
SUBJECT:
THE OPERATING REACTORS EVENTS MEETING Ncyc:ber 15, 1988 - HEETING 88-45 On November 15. 1988, an Operating Reactors Events meeting (88-45) was held to brief senior managers from NRR. AE00. OSP. RES. Commission Staff, and Regional Offices on events which occurred since our last meeting on November 8, 1988.
The list of attendees it, included as Enclosure 1.
The events discussed and the sfgnificant elements of these events are presented in Enclosure 2. presents a summary of reactor scrams.
Two significant events were' identified for input to NRC's performance indicator program.
'k y e D. L nning. Chie Events Assessment Branc h Division of Operationa'& Events Assessment
Enclosures:
As stated cc w/ Encl.:
See Next Page 4
0
E
.o e
e ENCLOSURE 1 LIST OF ATTENDEES OPERATING REACTORS EVENTS BRIEFING (88-45)
November 15, 1988 NAMe ORGANIZATION NAME ORGANIZATION C. Schulten NRR/00EA P. Baranowsky NRR/00EA R. Lobel NRR/DOEA C. Rossi NRR/00EA D. Crutchfield NRR/ADP S. Varga NRR/0RP G. Holahan NRR/0RSP T. Elsasser OCM/KC S. Juergens SECY M. Fields OSP
- 8. Siegei NRR/P03-2 A. Vietti-Cook OCM/LZ S. Sands NRR/P03-2 J. Stevens NRR/P03-2 M. Virgilio NRR/P03-1 J. Clifford 00 EOR 0 C. Harbuck ORSP/P017 C. Haughney ORIS K. Heitner NRR/P0lv W. Minners RES/DSIR e
l 9
9 g
e
,.m_
.,,__-._____,._m.
ENCLOSURE 2 OPERATING REACTORS EVENTS BRIEFING 88-45 EVENTS ASSESSMENT BRANCH LOCATION:
12-B-11 WHITE FLINT TUESDAY, NOVEMBER 15, 1988, 11:00 A.M.
BRAIDWOOD UNIT 2 MULTIPLE TRIPS CLINTON UNIT 1 LOSS OF 0FFSITE POWER SUPPLIES ARKANSAS UNITS 1 a 2 LOW LEVEL IN EMERGENCY COOLING POND 4
0 a
-4 4
0 e
a
88-45 BRAIDWOOD UNIT 2 MULTIPLE TRIPS 03/08/88 - 11/15/88 CAUSE DAIE POWER LEVEL EQUIPMENT FAILURE (7)
CABINET FAN FAILURE - R0D DROP 05/30 0% (MANUAL)
AUX, TRANSFORMER OVERCURRENT RELAY 06/20 49%
HEATER DRAIN VALVE 06/24 21%
PRESSURIZER PRESSURE BISTABLE 07/03 40%
EMERGENCY DRAIN VALVE 09/04 60% (MANUAL)
SOURCE RANGE BLOCK RELAY 09/19 2%
CONTROL R0D DRIVE M/G SET 11/05 88%
PERSONNEL / PROCEDURAL (5)
FEEDWATER ISOLATED 06/21 3%
FEEDWATER TRANSFER PROBLEM 06/22 25%
INSTRUMENT AIR VALVE MISPOSITIONED 07/24 75% (MANUAL)
ERROR DURING TESTING 09/29 38%
CLOTHING 1. EFT IN CONDENSER 10/25 89% (MANUAL)
OTHER LIGHTNING 10/17 88%
CONCLUS1QHS1 o
NO REPEAT OF CAUSES.
o CAUSES DIVIDED EVENLY BETWEEN EQUIPMENT AND PERSONNEL.
o THE LICENSEE USES A COMPUTER SYSTEM TO TEST THE RPS AND ESFAS INSTRUMENTATION, THIS AVOIDS ENTRIES'INTO CABINETS WHICH SHOULD REDUCE THE REACTOR TRIP RATE.
o REGION Ill IS MEETING MONTHLY WITH LICENSEE, CONTACT:
D. OUDIN0T
88 45 HISTORY OF TRIPS FOR BYRON /BRAIDWCOD STATIO(LS NUMBER OF TRIP 3 PLANT M
l81 82 M
(T0 11/15/88)
BYRON UNIT 1 25 5
5 3
11 5
BYRON UNIT 2 7
2 BRAIDWOOD UNIT 1 13 BRAIDWOOD UNIT 2 TRIPS PER 1000 CRITICAL H0llRS PLANT M
'.35 ffZ fBf (INITIAL CRITICALITY)
(T0 09/31/88)
BYRON 1 (02/02/85) 9.5 (1280)*
.64 (7812)*
.81 (6173)*
.58 (5176)*
1.73 (6358)*
.77 (6482)*
BYRON 2 (01/06/87)
~.-
2.92 (2397)*
.71 (1402)*
BRAID!f00D 1 (05/29/.87)
BRAIDWOOD 2 (03/08/88) 3.76 (2656)*
HOURS OF OPERATION O
e a
e o
O
88-45 COMPARISON OF TRIP RATES DATA DURING START-UP PERIOD FROM THE DATE OF CRITICALITY TO THE END OF THAT YEAR ELABI (INITIAL CRITICALITY)
TRIPS PER 1000 CRITICAL HOURS BEAVER VALLEY UNIT 2 (08/04/87) 7.34 V0GTLE (03/09/87) 5.01 PALO VERDE UNIT 1 (05/25/85) 4.53 PALO VERDE UNIT 2 (04/18/86) 4.51 i
SHEARON HARRIS (01/03/87) 3.06 i
MILLSTONE UNIT 3 (01/23/86) 2.40 BYRON 1 (02/02/85) 19.50 BYRON 2 (01/06/87) 1,73 BRAIDWOOD 1 (05/29/87) 2.92 BRAIDWOOD 2 (03/08/88) 3.76 4
)
r i
i
88-45 CLINTON UNIT 1 LOSS OF 0FFSITE POWER SUPPLIES NOVEMBER 14, 1988 PROBLEM LICENSEE LOST ONE OF TWO 0FFSITE POWER SUPPLIES AFTER LOSS OF MAIN TRANSFORMER DUE TO A FIRE.
CAUSE CONTROLLED ISOLATION OF BREAKER AFTER "ARCING" WAS OBSERVED: ARM FAILED.
SAFETY SIGNIFICANCE POTENTIAL FOR LOSS OF NORMAL A.C. POWER; ONLY VITAL LOADS REMAINED CONNECTED.
DISCUSSION o
ON NOVEMBER 11, 1988, A FIRE IN THE MAIN ELECTRICAL TRANSFORMER TRIPPED THE GENERATOR.
O MAIN TRANSFORMER REPLACEMENT SCHEDULED TO TAKE 3 TO 5 DAYS.
o' PLANT WENT TO MODE 3.
o ON NOVEMBER 14, 1988, THE RESERVE TRANSFORMER WAS LOST; POWER BEING SUPPLIED BY EMERGENCY RESERVE TRANSFORMER.
o RESERVE TRANSFORMER SCHEDULED FOR REPAIR BY EARLV 11/15/88, 0
o ON NOVEMBER 14, 1988. PLANT WAS COOLED TO 137 AT 0 PSI.
o PLANT RESPONDED AS DESIGNED.
'o ALL THREE DIESEL GENERATORS ARE OPERABLE.
o LIMITED LIGHTING SPDS AND PLANT COMPUTER INOPERABLE.
o OPEN TELEPHONE LINE WITH SITE BE!NG MAINTAINED.
FOLLOWUE o
REGION HAS DISPATCHED SECTION CHIEF AND ELECTRICAL SPECIALIST.
O PRELIMINARY NOTIFICATION WILL BE ISSUED.
O REGION AND NRR STAFF ON SITE 11/14/88 CONTACT:
J. CARTER
REFERENCE:
50.72 # 13970
,-,---y--
-n
.,n
,g-7
4 8
o M i
=
==
I
(( b l
'b,h I
. \\
~
e.n LE I
l"' i.ll!.g. ri l'=ma
-~
11 i!==m!
i et D
"aatd"^i g
.)
'G
_i Ll i
li f g
b-f
,N l,.
l
- 4
-wm E
( _
J s
,W i Gig =..
=
N,
W m, n
$-- Els.'"
8 a
2 f
gg gg l
!=~m'
~
5
. f3 0(it je,m s
b li 11 4
u g so.g al p II.
I D, EHlM Jw w' f
l W
i,.
t=ms IU>4
-'.=m 1
~E l o
~
3GE f~i
+
- f='f *.M f.
3
=
ww
=
1
88-45 ARKANSAS UNITS 1 & 2
_ LOW LEVEL IN EMERGENCY COOLING POND NOVEMBER 8, 1988 PROBLEM EMERGENCY COOLING POND LEVEL FELL BELOW TECHNICAL SPECIFICATION REQUIREMENT.
[BSE LEAKING SLUICE GATES.
SAFETY SIGNIFICANCE DEGRADATION OF DURATION FOR EMERGENCY DECAY HEAT REMOVAL.
DISCUSSION o
ANO 2 - AT 100% POWER ANO I - COLD SHUTDOWN 0
LICENSEE HAD BEEN DOING MOVATS TESTING ON UNIT 1 SLUICE GATES.
O PROCEDURE FOR OPERATING GATES HAS BEEN REVISED TO REQUIRE VERIFICATION OF PROPER CLOSURE BY HAND JACKING AFTER MOTOR OPERATED TRAVEL COMPLETED.
o AUX OPERATOR CHECKED EMERGENCY COOLING POND LEVEL TO BE 4.8 FEET.
o TECHNICAL SPECIFICATION 3.7.4.1.A REQUIRES THAT IT BE 5.0 FEET.
0 5.0 FEET PROVIDES COOLING WATER FOR BOTH UNITS FOR AT LEAST 30 DAYS, o
LICENSEE ESTIMATES 2500 GPM LOS'T FOR 3 DAYS OR 11.2 ACRE FEET (70. ACRE FEET REQUIRED),
o LICENSEE REPLENISHED EMERGENCY COOLING POND LEVEL TO 5.0 FEET IN 1 HOUR 15 MINUTES TO FXIT TECHNICAL SPECIFICATIONS.
o ANO I - SW FUMPS USED TO REPLENISH POND (CAPACITY 6500 GPM EACH OF 3.
o SLUICE GATES TORQUED DOWN TO REDUCE LEAK RATE.
~
FOLLOWUP REGION FOLLOWING LICENSEE'S EVALUATION OF SLUICE GATE DESIGN AND PROCEDURES.
CONTACT:
W. JENSEN
REFERENCE:
MORNING REPORT 11/08/88 AND 50.72 # 13932
LOOP 11 LOOPI ACW g3
,l h
h b
$g Vm vm 1418 1419 1421 1422 4
-4 E
E O
PONO A
B C
)
)
Y F_ _
a i
t i I I i
l l
l 8
I I
l,
', =Tu ',
l0 l
=>C.
l O
0 LAKE BAM QAATES AND WATER SCREENS
(
ARKANSAS UNIT 2 l
l if 5 oump powered from C pumo supo4,1421 and 1422 can not be esosed.
NOTE (1):
If S pump poworod from A pump suppy,1418 and 1419 con not be eteced.
1421 and 1422 have to be ctooed in order to open 1418 and 14*9 NOTE (2):
f 1425 and 1427 cioes on MSIS or STAS.
NOTE (3):
I 4
3 9
9 6
6 8
e e
e 4
9 l
e 5
e t, E 5' 5 j,
I C ta 5"
- g I,
V
- - 5 U#
1 h / -__-
(
s.%, g i
/
6 i
b R
s, e l
c b
]
n 5
5 W
m 5
C D
-o b k,- o
..j v
C
),
N i
n-a f
4 I
v O
D 8
E
, o
~
g d 9
a O
d A
5 e
2 ed E
E n
8 4
.o POND b
1 h
k
$v
'r
'r N
ACW u.
I I
I y
LAKE BASIN' j LEVEL l
=
,n_-
Papk i
ENCLOSURE 3 11/14/M PDFDWNI IEICAT3S S!31FICANT ESTS PUNT )WE EST EST DESCRIPil31 GTR S!9i1FICEE
_ DATE LIslCX1 10/03/36 TIME FIRE l4T9 ACCESS CGS EFE ET STRJCUALY 0 KTENTIN. F@ m ACTA CEEADATIGI 2RIFIG !O hliHSi40 Trf STEM FfESSifE F*G A HISH 7 SWETY-EATG E7)lF'OT D8SY LIE BREW, TdJS, STEM CulLD FtEiMTE MEAS WITH SMITY-RELAiG E2JIPtDT FEN: GIN 6 Tre IMytMKE
.Li s 0( 1 10/04/88 PEA ~.im FTSSJE 4 FE/4TE Lfdl INSTRJDTAi!) AS ELL 0 P0iENil4. F3 m ACTlR. DESP/ @ il31 1
AS M iCIC FLOW CONTE INSTFDDTS DI FEMOTE SKITI0fl 7 SWETY-PILAT G E2JIF s i FML C31D BE thAVAILAILE OGi!$ A FIRE EST IN MAIN CD(TE Rom. TESE INSTRISTS #E ECESSMY TO CDCJCT A PEMD1 SVE sic 081.
4 d
l e
j l
l
MET 0R SCRM SUMMAY NEEK D 01 0 11/13/88 4
!. PLANT SPECIFIC DATA
.DATE SITE UNIT POWER $18NAL CAUSE COMPLI-YTD TfD YTD CAfl0NS ABOYE DELON TOTAL 151 151 11/10/88 BRUNSNICK 1
71 A EQUIPENT NO 2
0 2-11/11/88 CLINTON 1
88 A EDUIPMENT NO 2
1 3
11/13/88 TROJAN
.1 100 A E90!PMENT N0 4
0 4
e 0
e 0
e e
D 4
4 h