f 4

I April 9, 196k i

Docket No. 50-205 1

l l

Mr. Leonard MArphy Chief, Seismology Branch U. S. Coast & Geodetic Survey Department of Commerca Washington 25, D. C.

Dear Mr. Murphy:

Enclosed for your information is a copy of Amendment-No. T to 4

the Pacific Gas and Electric Company application. This amend-ment sets forth further detail.s with Ngard to the earthquake design criteris for the Company's t,roposed Bodega Bay nactor.

As you know, we plan to provide a report on the adequacy of the criteria discussed in Amendments 6 and 7 to the ACRS for con-eideration at its May 196h meeting. A meeting vill be held on April ik in Bethesda to discuss this matter.

Sincemly yours,

Onr.naf Signed by E. G. Case Edscu 0. Case Acting Director Division of Reactor Licensing

Enclosure:

Amendment No. T

/

omcz >

.B..

..ES.C. eye.rbh SURNAME >

..h /926.4..

oArt >

Wrm AEC.818 (Rev. 9-63)

u. s. noveen s., e ieni. wriss so-as7as.s 8709230 f 00A217

~

PDR PO FIRESTOBS-sg5 pyg