Category:ENVIRONMENTAL MONITORING REPORTS(&RADIOLOGICAL)-PERIODIC
MONTHYEARML20206A3381998-12-31031 December 1998 1998 Radiological Environ Operating Rept for Fort Calhoun Nuclear Station Unit 1 ML20206A3501998-12-31031 December 1998 Annual Rept for TS Section 5.9.4.A for 980101-981231 for Fort Calhoun Nuclear Station Unit 1 ML20217P6121997-12-31031 December 1997 Annual Occupational Exposure Rept for 970101-1231 for Fort Calhoun Station ML20216D3991997-12-31031 December 1997 1997 Radiological Environ Operating Rept, for Fort Calhoun Nuclear Station,Iaw TS Section 5.9.4.b ML20216D3821997-12-31031 December 1997 Annual Rept for TS Section 5.9.4.a,Jan-Dec 1997 ML20199A6551996-12-31031 December 1996 Replacement Pages to FCS Unit 1 1996 Annual Effluent Release Rept ML20138H7341996-12-31031 December 1996 Annual Rept for TS Section 5.9.4.A for 960101-1231 LIC-97-0058, 1996 Radiological Environ Operating Rept1996-12-31031 December 1996 1996 Radiological Environ Operating Rept ML20199A6461995-12-31031 December 1995 Replacement Pages to FCS Unit 1 1995 Annual Effluent Release Rept LIC-96-0057, Radiological Environ Operating Rept for 19951995-12-31031 December 1995 Radiological Environ Operating Rept for 1995 ML20108A7071995-12-31031 December 1995 Annual Rept for Jan-Dec 1995 LIC-95-0138, SG Eddy Current Test Rept,1995 Refueling Outage1995-03-31031 March 1995 SG Eddy Current Test Rept,1995 Refueling Outage LIC-95-0089, Annual Rept for Tech Spec Section 5.9.1.B Jan-Dec 19941994-12-31031 December 1994 Annual Rept for Tech Spec Section 5.9.1.B Jan-Dec 1994 LIC-95-0053, Annual Occupational Exposure Rept for 19941994-12-31031 December 1994 Annual Occupational Exposure Rept for 1994 LIC-95-0093, Radiological Environ Operating Rept TS 5.9.4.b, for Period of 940101-12311994-12-31031 December 1994 Radiological Environ Operating Rept TS 5.9.4.b, for Period of 940101-1231 LIC-94-0083, Radiological Environ Operating Rept TS 5.9.4.b Jan-Dec 19931993-12-31031 December 1993 Radiological Environ Operating Rept TS 5.9.4.b Jan-Dec 1993 LIC-94-0039, Omaha Public Power District Fort Calhoun Station Unit 1 Annual Rept for TS Section 5.9.4.A for Jan-Dec 1993, W/1993-12-31031 December 1993 Omaha Public Power District Fort Calhoun Station Unit 1 Annual Rept for TS Section 5.9.4.A for Jan-Dec 1993, W/ ML20080K6861993-12-31031 December 1993 Suppl to FCS Annual Radioactive Effleunt Release Rept for 1993 ML20114D0991992-06-30030 June 1992 Semi-Annual Radioactive Effluent Release Rept for 920101-0630 ML20095H8251991-12-31031 December 1991 1991 Radiological Environ Operating Rept ML20094G8771991-12-31031 December 1991 Semiannual Radioactive Effluent Release Rept,Jul-Dec 1991 & Annual Occupational Exposure Rept,1991 ML20210D4351991-12-31031 December 1991 Quarterly Cumulative Dose Contributions from Radioactive Effluents for Fourth Quarter 1991 ML20077R5361991-06-30030 June 1991 Semiannual Rept for Tech Spec Section 5.9.4,Jan-June 1991 ML20082N4531991-06-30030 June 1991 Suppl to Semiannual Radioactive Effluent Release Rept for Jan-June 1991 ML20073B0481990-12-31031 December 1990 Radiological Environ Operating Rept for 1990,Fort Calhoun Station ML20079E6991990-12-31031 December 1990 Rev to Fort Calhoun Station 1990 Radiological Environ Operating Rept ML20029B2491990-12-31031 December 1990 Semi-Annual Radioactive Effluent Release Rept for Jul-Dec 1990 & Annual Occupational Exposure Rept. W/910228 Ltr ML20072R3951990-06-30030 June 1990 Suppl to Semiannual Radioactive Effluent Release Rept, Jan-June 1990 LIC-90-0743, Semiannual Rept for Tech Spec Section 5.9.4 Jan-June 19901990-06-30030 June 1990 Semiannual Rept for Tech Spec Section 5.9.4 Jan-June 1990 ML20006F9951989-12-31031 December 1989 Annual Rept for Tech Spec Section 5.9.1.b & App B,1989 & Semiannual Rept for Tech Spec Section 5.9.4,Jul-Dec 1989. Occupational Exposure Info Also included.W/900221 Ltr ML20042E9151989-12-31031 December 1989 Radiological Environ Operating Rept for Jan-Dec 1989. W/ 900430 Ltr ML20246K6711989-06-30030 June 1989 Semiannual Rept for Tech Spec Section 5.9.4,Jan-June 1989 ML20235V6831988-12-31031 December 1988 Annual Rept for Tech Spec Section 5.9.1.b & App B,1988 & Semiannual Rept for Tech Spec Section 5.9.4,Jul-Dec 1988 ML20245F0191988-12-31031 December 1988 Radiological Environ Operating Rept for 1988 ML20247G9741988-12-31031 December 1988 Corrected Semiannual Releases for Jul 1988 - Dec 1988 ML20153G0331988-06-30030 June 1988 Semiannual Rept for Tech Spec Section 5.9.4 Jan-June 1988 ML20153D3301987-12-31031 December 1987 Radiological Environ Monitoring Rept for 1987 ML20147D3381987-12-31031 December 1987 Annual Rept for Tech Spec Section 5.9.1.b & App B for 1987 & Semiannual Rept for Tech Spec Section 5.9.4 for Jul-Dec 1987 ML20210B5671987-12-31031 December 1987 Radiological Environ Operating Rept for 1986 ML20235V1951987-06-30030 June 1987 Corrected Page I-2 to Fort Calhoun Station Unit 1 Tech Specs Section 5.9.4a Semiannual Rept for Jan - June 1987 ML20237K2581987-06-30030 June 1987 Omaha Public Power District,Fort Calhoun Station Unit 1 Semiannual Rept for Tech Spec Section 5.9.4 for Jan-June 1987 ML20212A1161986-12-31031 December 1986 Rept Summarizing Effluent Releases & Environ Operations for Jul-Dec 1986 & Occupational Personnel Radiation Exposures for Jan-Dec 1986 ML20214V0551986-06-30030 June 1986 Suppl to Semiannual Rept Summarizing Updated Sr-89 & Sr-90 Results for Jan-June 1986.Results for Third Quarter 1986 Submitted on 870227.Fourth Quarter Results Will Be Forwarded When Available ML20209J2411986-06-30030 June 1986 Semiannual Rept for Tech Spec Section 5.9.4,Jan-June 1986, Summarizing Effluent Releases & Environ Operations ML20155G3351985-12-31031 December 1985 Annual Rept for Tech Spec 5.9.1.b,1985 & Semiannual Rept for Tech Spec 5.9.4,Jul-Dec 1985 ML20235J2941985-06-30030 June 1985 Corrected Effluent & Waste Disposal Rept Gaseous Effluents Summation of All Releases Jan-June 1985 ML20135E5751985-06-30030 June 1985 Semiannual Effluent Release & Environ Monitoring Rept,Jan-June 1985 ML20206D4041984-12-31031 December 1984 Supplemental Matl for 1984 Semiannual Repts ML20129B7821984-12-31031 December 1984 Annual Rept for Tech Spec Section 5.9.1b & App B,1984, Semiannual Rept for Tech Spec Section 5.9.4,Jul-Dec 1984. Rept Covers Effluent Releases ML20099G4651984-06-30030 June 1984 Semiannual Rept for Tech Spec Section 5.9.4,Jan-June 1984, Describing Effluent Releases & Environ Monitoring 1998-12-31
[Table view] Category:TEXT-ENVIRONMENTAL REPORTS
MONTHYEARML20206A3381998-12-31031 December 1998 1998 Radiological Environ Operating Rept for Fort Calhoun Nuclear Station Unit 1 ML20206A3501998-12-31031 December 1998 Annual Rept for TS Section 5.9.4.A for 980101-981231 for Fort Calhoun Nuclear Station Unit 1 ML20216B7211998-05-0707 May 1998 Environ Assessment & Finding of No Significant Impact Re Issuance of Exemption from Certain Requirements of 10CFR50, App R,Section Iii.O W/Respect to Certain Unpressurized Components ML20199J9581998-01-29029 January 1998 Environ Assessment & Finding of No Significant Impact Re Issuance of Exemption from Certain Requirements of 10CFR70.24(a) for Fort Calhoun Station,Unit 1 ML20216D3991997-12-31031 December 1997 1997 Radiological Environ Operating Rept, for Fort Calhoun Nuclear Station,Iaw TS Section 5.9.4.b ML20216D3821997-12-31031 December 1997 Annual Rept for TS Section 5.9.4.a,Jan-Dec 1997 ML20217P6121997-12-31031 December 1997 Annual Occupational Exposure Rept for 970101-1231 for Fort Calhoun Station LIC-97-0058, 1996 Radiological Environ Operating Rept1996-12-31031 December 1996 1996 Radiological Environ Operating Rept ML20199A6551996-12-31031 December 1996 Replacement Pages to FCS Unit 1 1996 Annual Effluent Release Rept ML20138H7341996-12-31031 December 1996 Annual Rept for TS Section 5.9.4.A for 960101-1231 ML20108A7071995-12-31031 December 1995 Annual Rept for Jan-Dec 1995 ML20199A6461995-12-31031 December 1995 Replacement Pages to FCS Unit 1 1995 Annual Effluent Release Rept LIC-96-0057, Radiological Environ Operating Rept for 19951995-12-31031 December 1995 Radiological Environ Operating Rept for 1995 LIC-95-0138, SG Eddy Current Test Rept,1995 Refueling Outage1995-03-31031 March 1995 SG Eddy Current Test Rept,1995 Refueling Outage LIC-95-0089, Annual Rept for Tech Spec Section 5.9.1.B Jan-Dec 19941994-12-31031 December 1994 Annual Rept for Tech Spec Section 5.9.1.B Jan-Dec 1994 LIC-95-0093, Radiological Environ Operating Rept TS 5.9.4.b, for Period of 940101-12311994-12-31031 December 1994 Radiological Environ Operating Rept TS 5.9.4.b, for Period of 940101-1231 LIC-95-0053, Annual Occupational Exposure Rept for 19941994-12-31031 December 1994 Annual Occupational Exposure Rept for 1994 LIC-94-0083, Radiological Environ Operating Rept TS 5.9.4.b Jan-Dec 19931993-12-31031 December 1993 Radiological Environ Operating Rept TS 5.9.4.b Jan-Dec 1993 ML20080K6861993-12-31031 December 1993 Suppl to FCS Annual Radioactive Effleunt Release Rept for 1993 LIC-94-0039, Omaha Public Power District Fort Calhoun Station Unit 1 Annual Rept for TS Section 5.9.4.A for Jan-Dec 1993, W/1993-12-31031 December 1993 Omaha Public Power District Fort Calhoun Station Unit 1 Annual Rept for TS Section 5.9.4.A for Jan-Dec 1993, W/ ML20056E0561993-07-29029 July 1993 Environ Assessment Re Expansion of Spent Fuel Pool.Eis Unwarranted ML20127E6061993-01-13013 January 1993 Notice of EA & Finding of No Significant Impact Re Issuance of Exemptions from Requirements of App J to 10CFR50 to OPPD for Plant Unit 1 ML20114D0991992-06-30030 June 1992 Semi-Annual Radioactive Effluent Release Rept for 920101-0630 ML20210D4351991-12-31031 December 1991 Quarterly Cumulative Dose Contributions from Radioactive Effluents for Fourth Quarter 1991 ML20094G8771991-12-31031 December 1991 Semiannual Radioactive Effluent Release Rept,Jul-Dec 1991 & Annual Occupational Exposure Rept,1991 ML20095H8251991-12-31031 December 1991 1991 Radiological Environ Operating Rept ML20079N3131991-11-11011 November 1991 Fish Impingement Study, Tech Spec 2.2 ML20077R5361991-06-30030 June 1991 Semiannual Rept for Tech Spec Section 5.9.4,Jan-June 1991 ML20082N4531991-06-30030 June 1991 Suppl to Semiannual Radioactive Effluent Release Rept for Jan-June 1991 ML20081H1021991-06-0606 June 1991 Suppl to 910402 NPDES Noncompliance Notification:On 910331, Ph Excursion from Outfall 002 Equalization & Decantation Holding Basis Occurred.Caused by Error in Valve Alignment. Actual Release Vol Was 55,000 Gallons Not 115,000 Gallons ML20084U6141991-04-10010 April 1991 NPDES Noncompliance Notification:On 910331,pH Excursion Occurred at 002 Chemical Holding Ponds.Caused by Error in Valve Alignment Directing Discharge Out High River Level Pipe Instead of Recirculating Waste Water within Lagoons ML20073B0481990-12-31031 December 1990 Radiological Environ Operating Rept for 1990,Fort Calhoun Station ML20079E6991990-12-31031 December 1990 Rev to Fort Calhoun Station 1990 Radiological Environ Operating Rept ML20029B2491990-12-31031 December 1990 Semi-Annual Radioactive Effluent Release Rept for Jul-Dec 1990 & Annual Occupational Exposure Rept. W/910228 Ltr ML20072R3951990-06-30030 June 1990 Suppl to Semiannual Radioactive Effluent Release Rept, Jan-June 1990 LIC-90-0743, Semiannual Rept for Tech Spec Section 5.9.4 Jan-June 19901990-06-30030 June 1990 Semiannual Rept for Tech Spec Section 5.9.4 Jan-June 1990 ML20006F9951989-12-31031 December 1989 Annual Rept for Tech Spec Section 5.9.1.b & App B,1989 & Semiannual Rept for Tech Spec Section 5.9.4,Jul-Dec 1989. Occupational Exposure Info Also included.W/900221 Ltr ML20042E9151989-12-31031 December 1989 Radiological Environ Operating Rept for Jan-Dec 1989. W/ 900430 Ltr ML20246K6711989-06-30030 June 1989 Semiannual Rept for Tech Spec Section 5.9.4,Jan-June 1989 ML20235V6831988-12-31031 December 1988 Annual Rept for Tech Spec Section 5.9.1.b & App B,1988 & Semiannual Rept for Tech Spec Section 5.9.4,Jul-Dec 1988 ML20247G9741988-12-31031 December 1988 Corrected Semiannual Releases for Jul 1988 - Dec 1988 ML20245F0191988-12-31031 December 1988 Radiological Environ Operating Rept for 1988 ML20195J8881988-11-30030 November 1988 Environ Assessment & Finding of No Significant Impact Re Licensee 880902 Application Supporting Cycle 12 Operation W/ Extended Fuel Irradiation Levels ML20154P1531988-09-26026 September 1988 Notice of Environ Assessment & Findings of No Significant Impact Re Exemption from 10CFR50.54 ML20153G0331988-06-30030 June 1988 Semiannual Rept for Tech Spec Section 5.9.4 Jan-June 1988 ML20153D3301987-12-31031 December 1987 Radiological Environ Monitoring Rept for 1987 ML20210B5671987-12-31031 December 1987 Radiological Environ Operating Rept for 1986 ML20147D3381987-12-31031 December 1987 Annual Rept for Tech Spec Section 5.9.1.b & App B for 1987 & Semiannual Rept for Tech Spec Section 5.9.4 for Jul-Dec 1987 ML20236X6961987-11-25025 November 1987 Environ Assessment & Finding of No Significant Impact Supporting Exemption from 10CFR50.54(w)(1) Requirements Re Maint of Min Insurance Coverage ML20236H4121987-07-29029 July 1987 Environ Assessment Supporting Extension of License Expiration Date to 130809 W/O Preparation of EIS 1998-05-07
[Table view] |
Text
- _ _ _ _ _ , . _ . _ - . . - _ . . _ . ._. . . . _ . . . - . . . ~ _, ,. _._.._.m _ _ - _m..__ _ _ _ _ . . _ . . . _ _ . . _ . . _ _
v TABLE 1A i- .
- EFFLUENT ANO dASTE DISPOSAL REPORT e
1 GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES
.t SEMIANNUAL FOR JAN THRU JUN 86 a
1 QUARTER 2 QUARTER NUCLIDES IN CURIES CONT DECAY RM060 TOTAL CONT DECAY RM060 TOTAL A. FISSION & ACTIVATION GASES TOTAL RELEASE CI 6.22E+01 1.17E-01 0.00E+00 6.23E+01 1.58E+02 1.91E-01 0.00E+00 1.58E+02 l
AVG RELEASE RATE
.j FOR PERIOD UCI/SEC 8.00E+00 1.50E-02 0.00E+00 8.01E+00 2.01E+01 2.43E-02 0.00E+00 2.01E+01 PERCENT OF LIMIT ,
TECH SPEC = NONE %
10 DINES
) 8.
TOTAL RELEASE IODINE - 131 CI 0.00E+00 0.00E+00 7.87E-05 7.87E-05 0.00E+00 0.00E+00 1.42E-04 1.42E-04 5 AVG RELEASE RATE FOR PERIOD UCI/SEC 0.00E+00 0.00E+00 1.01E-05 1.01E-05 0.00E+00 0.00E+00 1.80E-05 1.80E-05 PERCENT OF LIMIT TECH SPEC = NONE %
- C. PARTICULATES i PARTICULATES WITH HALF j LIVES .GT. 8 OAYS CI 0.00E+00 0.00E+00 1.27E-05' 1.27E-05 0.00E+00 0.00E+00 1.68E 1.68E-06 AVG RELEASE RATE FOR PERIOD UCI/SEC .0.00E+00 0.00E+00 1.63E-06 1.63E-06 0.00E+00 0.00E+00 2.13E-07 2.13E-07 PERCENT OF LIMIT TECH SPEC = NONE %
i GROSS ALPHA RADIOACTIVITY CI 0.00E+00 0.00E+00 0.00E+00 0.00E+00. 0.00E+00 0.00E+00 0.00E+00 0.00E+00 D. TRITIUM TOTAL RELEASE CI 6.42E-02 0.00E+00 0.00E+00 6.42E-02 4.05E-01 0.00E+00 0.00E+00 4.05E AVG RELEASE RATE j FOR PERIOD UCI/SEC 8.26E-03 0.00E+00 0.00E+00 8.26E-03 5.15E-02 0.00E+00 0.00E+00 5.15E-02 1 PERCENT OF LIMIT TECH SPEC a NONE %
H
@ 8706110428 860630 ADOCK 05000285 7 '
44.og
. PDR R PDR d
?
~
s TABLE 1C .
EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES 4
SEMIANNUAL FOR JAN THRU JUN 86 1 QUARTER 2 QUARTER NUCLIOES IN CURIES . CONT DECAV RM060 TOTAL CONT DECAY RM060 -TOTAL FISSION GASES
. XENON-133 6.05E+01 4.41E-05 0.00E+00 6.05E+01 1.54E+02 1.73E-03 0.00E+00 1.54E+02 KRYPTON-85M 6.57E-03 0.00E+00 0.00E+00 6.57E-03 3.50E-02 0.00E+00 0.00E+00 3.50E-02 XENON-131M 5.95E-02 7.95E-04 0.00E+00 6.03E-02 1.15E+00 0.00E+00 0.00E+00 1.15E+00 KRYPTON-88 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 XENON-133M 5.01E-01 0.00E+00 0.00E+00 5.01E-01 1.05E+00 0.00E+00 0.00E+00 1.05E+00 XENON-135 7.86E-01 0.00E+00 0.OOE+00 7.86E-01 1.41E+00 0.00E+00 0.00E+00 1.41E+00 KRYPTON-87 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.79E-03 0.00E+00 0.00E+00 4.79E-03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
' XENON-138 0.00E+00 .1.90E-01 0.00E+00 KRYPTON-85 0.00E+00 1.16E-01 1.16E-01 0.00E+00 1.90E-01 XENON-135M 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00' O.00E+00 0.00E+00 ARGON-41 3.87E-01 0.00E+00 0.00E+00 3.87E-01 5.64E-01 0.00E+00 0.00E+00 5.64E-01 TOTAL FOR PERIOD 6.22E+01 1.17E-01 0.00E+00 6.23E+01 1.58E+02 1.91E-01 0.00E+00 1.58E+02 10 DINES 10 DINE-131 CTD. 0.00E+00 0.00E+00 7.87E-05 7.87E-05 0.00E+00 0.00E+00 1.42E-04 .1.42E-04 10 DINE-133 CTD. 0.00E+00 0.00E+00 6.85E-04 6.85E-04 0.00E+00 0.00E+00 9.40E-04 9.40E-04 IODINE-135 CTD. 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
, TOTAL FOR PERIOD 0.00E+00 0.00E+00 7.64E-04 7.64E-04 0.00E+00 0.00E+00 1.08E-03 1.08E-03 PARTICULATES STRONTIUM-89 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.COE+00 0.00E+00 0.00E+00 STRONTIUM-90 0.00E+00 0.00E+00 5.13E-08 5.13E-08. 0.00E+00 0.00E+00 6.36E-08 6.36E-08 IODINE-131 PRF. 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00' 100!NE-133 PRF. 0.00E+00 0.00E+00 G.00E+00 0.00E+00 0.00E+00 .0.00E+00 0.00E+00 0.00E+00
- BARIUM-140 0.00E+00 0.00E+00 0.00E+00 0.00E+00 -0.00E+00- 0.00E+00 0.00E+00 0.00E+00 CESIUM-137 0.00E+00 0.00E+00 3.50E-06 3.50E-06 0.00E+00 0.00E+00 1.61E-06 1.61E-06 CESIUM-134 0.00E+00 0.00E+00 2.27E-06 2.27E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00
. COBALT-58 0.00E+00 0.00E+00 6.88E-06 6.88E-06 0.00E+00 0.00E+00 'O.00E+00 0.00E+00 MANGANESE-54 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00, 0.00E+00 0.00E+00 0.00E+00 COBALT-60 0.00E+00 0.00E+00 0,00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 10 DINE-135 PRF. 0.00E+00 0.00E+00 0.00E+00 'O 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LANTHANUM-140 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CERIUM-144 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CERIUM-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0,00E+00 0.00E+00 0.00E+00 i MOLY 8DENUM-99 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 IRON-59 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 21NC-F5 0.00E+00 0.00E+00 0.00E+00. 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.27E-05. 1.27E-05 0.00E+00, 0.00E+00 1.68E-06, 1.68E-06 TOTAL FOR PERIOD 0.00E+00 ALPHA. TRITIUM & OTHER ALPHA 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00. 0.00E+00 0.00E+00 TRITIUM 6.42E-02 0.00E+00 0.00E+00 6.42E-02 4.05E-01~ 0.00E+00- 0.00E+00 4.05E-01 GROSS BETA / GAMMA 0.00E+00 0.00E+00 2.69E-07 2.69E-07 0.00E+00 0.00E+00' 2.12E-07 2.12E-07
+
- - _ n-
s ~ ; " ' ;
~
~ .
TABLE 20 -
EFFLUENT AND WASTE DISPOSAL RFPORT w
~ , .
LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 86 1 QUARTER 2 QUARTER A. FISSION & ACTIVATION PRODUCTS ' '-
TOTAL RELEASE (NO ~'- %
TRITIUM, GAS, ALPHA) CI 6.290-02 5.86E-03 '
" " !~
AVG DILUTED C .~ ,
CONCENTRATION UCI/ML 2.75E-10 3.64E-11 'E PERCENT OF LIMIT 10 CFR 20 APP. B= 1.0E-07 % 2.75E-01 3.64E-02 B. TRITIUM - '~
TOTAL RELEASE CI 2.89E+00 5.29E'01 ' -
~
AVG DILUTED CONCENTRATION UCI/ML 1.26E-08 3.28E-07 PERCENT OF LIMIT 10 CFR 20 APP. B= 3.0E-03 % 4.21E-04 1.09E-02 -
C. DISSOLVED & ENTRAINED GASES TOTAL RELEASE CI 4.95E-02 4.38E-02 AVG DILUTED 3 CONCENTRATION UCI/ML 2.16E-10 2.72E-10 .f PERCENT OF LIMIT TECH SPEC = 2.0E-04 UCI/ML % 1.08E-04 1.36E-04 .
D. GROSS ALPHA RADIOACTIVITY TOTAL RELEASE CI 3.66E-04 2.12E-05 E. VOLUME OF WASTE RELEASE
~
PRIOR TO DIL. LITERS 4.57E+07 2.22E+07 F. VOLUME OF DILUTION WATER THIS PERIOD LITERS 2.29E+11 1.61E+11
__.._ ___ _ .._~.- _ . . . . . . __ ..~ - . _ -- ._ . _ - - _ . - _ _ _.m-.m. . . . -- _ . - . . _ - - ..- m-- . -
..y. _ . _ .
TABLE 2B EFFLUENT AND WASTE DISPOSAL REPORT
.=
LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 86 1 QUARTER 2 OVARTER 4 g NUCLIOES IN CURIES ~ ~ CONT BATCH CONT BATCH STRONTIUM-89 1.60E-03 2.38E-04 0.00E+00 1.43E-04 STRONTIUM-90 1.43E-04 1.18E-04 7.54E-05 3.44E-05 COBALT-57 0.00E+00 0.00E+00. 0.00E+00 0. 7E+00-MOLv80ENUM-99 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TECHNETIUM-99M 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CERIUM-141 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TIN-117M 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4
CHROMIUM-51 0,00E+00 0.00E+00 0.00E+00 0.00E+00 10 DINE-131 0.00E+00 4.72E-05 0.00E+00 1.07E-04 10 DINE-133 0.00E+00 0.00E+00 'O.00E+00 0.00E+00 BARIUM-140 0.00F+00 .0.00E+00 0.00E+00 0.00E+00 RUTHENIUM-103 0.ett-00 0.00E+00 0.00E+00 0.00E+00 CESIUM-137 6.7h -03 6.29E-03 .0.00E+00 2.55E-03 ZIRCONIUM-95 0.000+00 0.00E+00 0.00E+00 2.64E-05
- 'M-95 0.00E+00 7.77E-06 0.00E+00 6.43E-05
.. 134 3.14E-03 3.54E-03 0.00F+00 1.30E-03
.38Au. - 58 0.00E+00 1.26E-02 0.00L*00 1.36E-03 MANGANESE-54 0.00E+00 1.37E-04 0.00L+00 4.54E-05 CESIUM-136 0.00E+00 0.00E+00 0.00E+00 0.00E+00 -
IRON-59 0.00E+00 0.00E+00- 0.00E+00 0.00E+00 ZINC-65 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ,
COBALT-60 5.01E-03 3.08E-04 0.00E+00, 4.62E-05 LANTHANUM-140 0.00E+00 0.00E+00 1.00E+00 0.00E+00 ANTIMONY-124 0.00E+00 0.00E+00 0.00E+00. 0.00E+00 '
CERIUM-144 0.00E+00 0.00E+00 0.00E+00 1.12E-04 ANTIMONY-125 2.29E-02 0.00E+00- 0.00E+00 0.00E+00 +
SILVER-110M 0.00E+00 0.00E+00 0.00E+00. 0.00E+00 TOTAL FOR PERIOD 3.96E-02 2.33E-02 7.54E-05 5.79E-03 OISSOLVED GASES l
ENTRAINED GASES XENON-133 0.00E+00 4.79E-02 0.00E+00 4.32E-02 XENON-135 0.00E+00 1.58E-03 .0.00E+00 .5.71E-04
- . TOTAL FOR PERIOD 0.00E+00 4.95E-02 0.00E+00 4.38E-02
, OTHER. ALPHA & TRITIUM i
ALPHA 3.59E-04 6.96E-06 2.08E-05 3.39E-07 i TRITIUM . 1.06E-01 .2.78E+00 3.53E-02. 5.28E+01 GROSS BETA / GAMMA O 00E+00 0.00E+00 0.00E+00' 0.00E+00 TOTAL FOR PERIOD 1.06E-01 2.78E+00 3.54E-02 5.28E+01 ,
AVG. CONC. IN UCI/ML ALPHA 6.'14E-12 4.19E-12 5.97E-13 5.31E-13 TRITIUM 1.77E-09 2.13E-06 7.39E-10 2.23E-05 i
1 a
i
- v ,, - -
Omaha Public Power District l 1623 Harney Omaha. Nebraska 68102 2247 '
402/536-4000 3
June 2, 1987 LIC-87-340 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
References:
- 1. Docket No. 50-285
- 2. Letter OPPD (R. L. Andrews) to NRC dated February 27, 1987 (LIC-87-123)
Gentlemen:
SUBJECT:
Strontium 89-90 Results - Supplement to Semi-Annual and Annual Reports In accordance with 10 CFR Section 50.36a, and the Fort Calhoun Station Unit No.1 Technical Specifications Section 5.9.4a., please find enclosed one (1) copy of OPPD's report that summarizes the updated Sr 89-90 results for the 1st and 2nd quarters of 1986. Results for the 3rd quarter, 1986 were previously submitted per Reference 2, and the Sr 89-90 updates for the 4th quarter of 1986 will be forwarded as they become available.
If you require any additional information, please contact us.
Sincerely,
& ?A R. L. Andrews Division Manager Nuclear Production RLA/me c: LeBoeuf, Lamb, Leiby & MacRae J. A. Calvo, NRC Project Director W. A. Paulson, NRC Project Manager P. H. Harrell, NRC Senior Resident Inspector H. E. Simmons, Director Division of <'
Radiological Health -
l-g,
- - = - ,
- - _ _ _ _ _ _ _ _ _