ML20147D338

From kanterella
Jump to navigation Jump to search
Annual Rept for Tech Spec Section 5.9.1.b & App B for 1987 & Semiannual Rept for Tech Spec Section 5.9.4 for Jul-Dec 1987
ML20147D338
Person / Time
Site: Fort Calhoun 
Issue date: 12/31/1987
From: Andrews R, Gates W
OMAHA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
LIC-88-143, NUDOCS 8803030290
Download: ML20147D338 (194)


Text

{{#Wiki_filter:_- Omaha Public Power District l Fort Calhoun Station Unit No.1 Annual Report Semi Annual Report for for Technical Specification Technical Specification Section 5.9.1.b Section 5.9.4 and Appendix 11 July 1,1987 to January 1,1987 to December 31, 1987 inclusive December 31, 1987 V..%- ,^ R k , :,..., p%., S n3 7 4 h -M t. k b.' + 4 \\ e c <. r. s- . gs ~~ s ;4 - .( . '.^ Docket No. 50-285 Operating Licent.e No. DPR-40'I',qj 8803030290 071231 DR ADOCK 050 5 g )

G INTRODUCTION k.j.: This report is submitted in accordance with Sections 5.9.1.b and 5.9.4.a of the Technical Specifications of the Fort Calhoun Station Unit No. 1, Facility Operating License DPR-40. This report covers the period of January 1, 1987 through December 31, 1987 for the Annual Occupational Exposure Report for Technical Specification 5.9.1.b and the period of July 1, 1987 through December 31, 1987 for the Semi-Annual Effluent Report for Technical Specification 5.9.4.a. The Effluent Report is presented in the format outlined in Regulatory Guide 1.21, Revision 1. In addition, this report provides the results of quarterly dose calculations performed in accordance with Technical Specification Sections 2.9.1(1) band 2.9.1(2)b. Results are presented by quarter for the period October 1, 1985 through December 31, 1987. Further, descriptions of any changes made during the preceding six months to the Offsite Dose Calculation Manual and/or the Process Control Program for the Fort Calhoun Station are presented. .T. lb E - 3 W. Gary Gates Manager Fort Calhoun Station

i TABLE OF CONTENTS: SECTION SECTION TITLE a Introduction I Quarterly Doses from Effluents TechnicalSpecifications(2.9.1(1) band 2.9.1(2)b) II Annual Occupational Exposure Re) ort TechnicalSpecification(5.9.1.)) III Radioactive Effluent Releases-Gaseous Effluents TechnicalSpecification(5.9.4.a) Table 1A Sumation of Releases Table IB Not Applicable Table 1C Sumation of All Releases IV Radioactive Effluent Releases-Liquid Effluents l TechnicalSpecification(5.9.4.a) Table 2A Sumation of All Releases Table 28 Sumation of All Releases V Radioactive Effluent Releases-Solid Radioactive l Waste, 00CM, and PCP Changes TechnicalSpecification(5.9.4.a) VI Joint Frequency Distribution Wind Direction vs. WindSpeedbyStability(ClassandMeteorology) Data Per Batch Release Regulatory Guide 1.21 VII Potential Doses to Individuals and Populations (Regulatory Guide 1.21) O

'l i l i l 1 ~ 1-I E. 'I I l l SECTION ! i j QUARTERLY DOSES FROM EFFLUENTS j Technical Specifications 2.9.1(1)b and 2.9.1(2)b E a October 1, 1985 - December 31, 1987 i l i l I i i I I-1 l l - - ~.

pQ Quarterly Dose Calculation Results October 1, 1985 through December 31, 1987 With the implementation of the Fort Calhoun Station Radiological Effluent TechnicalSpecifications(RETS)onOctober1,1985,radiationdosesinthe unrestricted area from liquid and gaseous effluents must be calculated on a quarterly basis in accordance with Sections 2.9.1(1)b and 2.9.1(2)b. These calculations are performed to ensure the annual dose limits delineated in Appendix I of 10 CFR Part 50 and implemented by the RETS are not exceeded. If the results of the quarterly calculations exceed fifty percent (50%) of the annual limits of Appendix 1, actions are taken to reduce effluents so that resultant doses do not exceed the annual limits during the remainder of the year and a special report is submitted to the NRC. This section presents the results of the quarterly dose calculations per-formed since October 1, 1985. Details are shown in Tables on pages 1-3 through I-11 as to the types, sources and resultant doses from the effluents, annual limits and a comparison to the annual limits. As can be seen by review of the quarterly calculational results, OPPD is in compliance with the referenced Technical Specifications. The quarterly totals are well below the 50's annual dose acceptance criteria. In addition, the sumation of the quarterly totals shows OPPD to be less than the annual limits and in compliance with the regulations and Technical Specifications. O l-2

FC-421 FORM REY. 1 02-13-88 ~ FORT CALHOUN STATION UNIT _NO. 1 QUARTERLY CUMULATIVE DOSE CONTRIBUTIONS t FROM RADIOACTIVE EFFLUENTS l ( QUARTER FOURTH, 1985 i A. LIQUID EFFLUENTS: TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM) .(LIVER, MREM) MONITOR / HOTEL TANK 7.18E-01 9.80E-01 STEAM GENERATOR 5.38E-04 4.07E-04 TOTALS 7.18E-01 9.81E-01 TECH SPEC 2.9.'1.A I OBJECTIVE 3.0 10.0 PERCENT OF OBJECTIVE 23.94 % 9.81 % B. GASEOUS EFFLUENTS: < O TOTAL BODY GAMMA TOTAL BODY BETA DOSE (MRAD) DOSE (MRAD) 1. NOBLE GAS AIR DOSE 3.74E-02 1.16E-01 TECH SPEC 2.9.1.B 10.0 20.0 i i PERCENT OF OBJECTIVE 0.37 % 0.58 % L TOTAL BODY 00SE CRITICAL ORGAN DOSE I (MREM) (THYROID, MREM) 2. 1-131, H-3, AND r PARTICULATES WITH j HALF-LIVES > 8 DAYS f INHALATION

  • 1.45E-04 1.14E-02 GROUND AND FOOD
  • 2.30E-03 1.18E+00 l

1 TOTALS 2.44E-03 1.19E+00 j TECH SPEC 2.9.1.B OBJECTIVE 15.0 15.0 PERCENT OF OBJECTIVE 0.02 % 7.95 % i

  • - HIGHEST OF INFANT OR CHILD DOSE FACTORS l

FC/ FORM /01 !-3 h

FC-421 FORT CALHOUN STATION UNIT NO. 1 QUARTERLY CUMULATIVE DOSE CONTRIBUTIONS FROM RADI0 ACTIVE EFFLUENTS QUARTER-FIRST. 1986 A. LIQUID EFFLUENTS: TOTAL BODY DOSE CRITICAL ORGAN 00SE (MREM) (LIVER, MREM) MONITOR / HOTEL TANK 6.38E-02 8.79E-02 STEAM GENERATOR 9.01E-02 1.25E-01 -TOTALS 1.54E-01 2.13E-01 TECH SPEC 2.9.1.A OBJECTIVE 3.0 10.0 PERCENT OF OBJECTIVF 5.13 % 2.13 % 2 B. GASEOUS EFFLUENTS: O TOTAL BODY GAMMA TOTAL BODY BETA i DOSE (MRAD) DOSE (MRAD) l-1. NOBLE GAS AIR DOSE 1.25E-02 3.19E-02 TECH SPEC 2.9.1.8 10.0 20.0 PERCENT OF OBJECTIVE 0.12 % 0.16 % t TOTAL BODY DOSE CRITICAL ORGAN DOSE j (MREM) (THYROID, MREM) i 2. 1-131 H-3, AND l PARTICULATES WITH HALF-LIVES > 8 DAYS INHALATION

  • 8.94E-06 1.98E-04 GROUND AND FOOD
  • 1.12E-04 1.98E-02 TOTALS 1.21E-04 2.00E-02 TECH SPEC 2.9.1.B OBJECTIVE 15.0 15.0 PERCENT OF OBJECTIVE 0.00 t 0.13 %
  • - HIGHEST OF INFANT OR CHILD DOSE FACTORS FC/ FORM /01 I-4

FC-421 FORM REY. 1 02-13-88 h FORT CALHOUN STATION UNIT NO.'l (, QUARTERLY CUMULATIVE DOSE CONTRIBUTIONS FROM RADI0 ACTIVE EFFLUENTS QUARTER SECOND, 1986 A. LIQUID EFFLUENTS: TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM) (LIVER. MREM) MONITOR / HOTEL TANK 2.21E-02 3.05E-02 STEAM GENERATOR 2.57E-07 2.57E-07 TOTALS 2.21E-02 3.05E-02 TECH SPEC 2.9.1.A OBJECTIVE-3.0 10.0 PERCENT OF OBJECTIVE 0.74 % 0.31 % B. GASE0US EFFLUENTS: O TOTAL BODY GAMMA TOTAL BODY BETA D DOSE (MRAD) DOSE (MRAD) 1. N0BLE GAS AIR DOSE 2.94E-02 8.01E-02 TECH SPEC 2.9.1.8 10.0 20.0 PERCENT OF OBJECTIVE 0.29 % 0.40 % TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM) (THYROID, MREM) 2. I-131. H-3, AND PARTICULATES WITH HALF-LIVES > 8 DAYS INHALATION

  • 5.41E-05 2.89E-04 GROUND AND FOOD
  • 3.27E-04 2.49E-02 TOTALS 3.01E-04 2.52E-02 TECH SPEC 2.9.1.8 OBJECTIVE 15.0 15.0 PERCENT OF CBJECTIVE 0.00 %

0.11 %

  • - HIGHEST OF INFANT OR CHILD DOSE FACTORS FC/ FORM /01 I-5

FC-421 i FORM REY. 1 02-13-88 O' FORT CALHOUN STATION UNIT NO. 1 V) t QUARTERLY CUMULATIVE DOSE CONTRIBUTIONS FROM RADI0 ACTIVE EFFLUENTS QUARTER THIRD, 1986 A. LIQUID EFFLUENTS: TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM) (LIVER, MREM) MONITOR / HOTEL TANK 5.86E-02 8.03E-02 STEAM GENERATOR 5.26E-03 7.51E-08 TOTALS 6.38E-02 8.03E-02 TECH SPEC 2.9.1.A i OBJECTIVE 3.0 10.0 PERCEH7 0F OBJECTIVE 2.13 % 0.80 % i B. GASEOUS EFFLUENTS: O TOTAL BODY GAMMA TOTAL BODY BETA DOSE (MRAD) DOSE (MRAD) 1. NOBLE GAS AIR DOSE 3.69E-02 1.02E-01 TECH SPEC 2.9.1.B 10.0 20.0 PERCENT OF OBJECTIVE 0.37 % 0.51 % TOTAL BODY DOSE CRITICAL ORGAN DOSE l (MREM) (THYROID, MREM) 2. 1-131. H-3, AND PARTICULATES WITH. l HALF-LIVES > S D/,YS l INK'aATIO.N

  • 6.97E-05 1.11E-03 GROUND AND FOOD
  • 5.30E-04 1.10E-01 TOTALS 5.99E-04 1.11E-01 TECH SPEC 2.9.1.B OBJECTIVE 15.0 15.0 PERCENT OF OBJECTIVE 0.00 %

0.74 t

  • - HIGHEST OF INFANT OR CHILD DOSE FACTORS FC/ FORM /01 I-6

FC-421 FORM REY. 1 02-13-88 [O 3 FORT CALHOUN STATION UNIT N0. 1 QUARTERLY CUMULATIVE DOSE CONTRIBUTIONS FROM RADI0 ACTIVE EFFLUENTS QUARTER FOURTH 1986 -A. LIQUID EFFLUENTS: TOTAL BODY DOSE CRITICAL ORGAN DOSE .(MREM) (LIVER, MREM) MONITOR / HOTEL TANK 1.57E-02 2.15E-02 STEAM GENERATOR 6.46E-04 7.04E-04 TOTALS 1.63E-02 2.22E-02 c TECH SPEC 2.9.1.A OBJECTIVE 3.0 10.0 PERCENT OF OBJECTIVE 0.54 % 0.22 % l i B. GASEOUS EFFLUENTS: [ TOTAL BODY GAMMA TOTAL BODY BETA DOSE (MRAD) DOSE (MRAD) i s 3 1. NOBLE GAS AIR DOSE 2.83E-02 7.52E-02 TECH SPEC 2.9.1.B 10.0 20.0 PERCENT OF OBJECTIVE 0.28 % 0.38 % i t f TOTAL BODY DOSE CRITICAL ORGAN DOSE I (MREM) (THYROID, MREM) l 2. I-131, H-3, AND l PARTICULATES WITH HALF-LIVES > 8 DAYS t INHALATION

  • 5.56E-05 1.30E-03 GROUND AND FOOD
  • 4.88E-04 1.30E-01 TOTALS 5.43E-04 1.32E-01 i

1 TECH SPEC 2.9.1.8 I OBJECTIVE 15.0 15.0 j PERCENT OF OBJECTIVE 0.00 1 0.88 %

  • - HIGHEST OF INFANT OR CHILD DOSE FACTORS FC/ FORM /01 I-7

FC-421 FORM REV. 1 02-13-88 FORT CALHOUN STATION UNIT NO. 1 QUARTERLY CUMULATIVE DOSE CONTRIBUTIONS FROM RADI0 ACTIVE EFFLUENTS QUARTER FIRST, 1987 A. LIQUID EFFLUENTS: TOTAL BODY 00SE CRITICAL ORGAN DOSE (MREM) (LIVER, MREM) MONITOR / HOTEL TANK 8.03E-02 1.11E-01 STEAM GENERATOR 2.75E-07 2.75E-07 TOTALS 8.03E-02 1.11E-01 TECH SPEC 2.9.1.A OBJECTIVE 3.0 10.0 PERCENT OF OBJECTIVE 2.68 % 1.11 % B. GASE0US EFFLUENTS: O TOTAL BODY GAMMA TOTAL BODY BETA DOSE (MRAD) DOSE (MRAD) 1. N0BLE GAS AIR DOSE 6.65E-02 1.92E-01 TECH SPEC 2.9.1.B 10.0 20.0 PERCENT OF OBJECTIVE 0.67 % 0.96% TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM) (THYROID, MREM) 2. 1-131. H-3. AND PARTICULATES WITH HALF-LIVES > 8 DAYS INHALATION

  • 3.01E-04 5.41E-03 GROUND AND FOOD
  • 2.28E-03 5.37E-01 TOTALS 2.58E-03 5.42E-01 TECH SPEC 2.9.1.8 OBJECTIVE 15.0 15.0 PERCENT OF OBJECTIVE 0.02 %

3.62 %

  • - HIGHEST OF INFANT OR CHILD DOSE FACTORS FC/ FORM /01

!-8

FC-421 FORM REY. 1 02-13-88 FORT CALHOUN STATION UNIT NO. 1 QUARTERLY CUMULATIVE DOSE CONTRIBUTIONS FROM RADI0 ACTIVE EFFLUENTS QUARTER SECOND. 1987 A. LIQUID EFFLUENTS: TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM) (LIVER, MREM) MONITOR / HOTEL TANK 4.54E-01 6.28E-01 STEAM GENERATOR 1.38E-03 2.11E-03 TOTALS 4.55E-01 6.30E-01 J TECH SPEC 2.9.1.A OBJECTIVE 3.0 10.0 PERCENT 0F OBJECTIVE 15.178 % 6.304 % B. GASEOUS EFFLUENTS: 4 j TOTAL BODY GAPNA TOTAL BODY BETA DOSE (MRAD) DOSE (MRAD) i 1. N0BLE GAS AIR DOSE 2.79E-04 7.07E-04 TECH SPEC 2.9.1.B 10.0 20.0 PERCENT OF OBJECTIVE 0.003 % 0.004 % j TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM) (THYROID, MREM) j 2. 1-131. H-3, AND PARTICULATES WITH HALF-LIVES > 8 DAYS INHALATION

  • 2.16E-05 3.03E-03 GROUND AND FOOD
  • 9.67E-04 6.39E-01 TOTALS 9.89E-04 6.42E-01 TECH SPEC 2.9.1.8 4

OBJECTIVE 15.0 15.0 PERCENT OF OBJECTIVE 0.007 % 4.280 %

  • - HIGHEST OF INFANT OR CHILD DOSE FACTORS FC/ FORM /01 1-9 l

FC-421 FORM REY. 1 02-13-88 FORT CALHOUN STATION UNIT NO. 1 QUARTERLY CUMULATIVE DOSE CONTRNtiTIONS FROM RADI0 ACTIVE EFFLUENTS : -QUARTER THIRD, 1987 A. LIQUID EFFLUENTS: TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM) (LIVER, MREM) MONITOR / HOTEL TANK 8.39E-02 1.16E-01 STEAM GENERATOR 5.54E-04 3.26E-08 TOTALS 8.45E-02 1.16E-01 TECH SPEC 2.9.1.A OBJECTIVE

1.0 10.0 PERCENT OF OBJECTIVE 2.816 %

1.158 % 8. GASEOUS EFFLUENTS: O TOTAL BODY GAMMA TOTAL BODY BETA DOSE (MRAD) DOSE (MRAD) 1. NOBLE GAS AIR DOSE 1.53E-03 2.18E-03 TECH SPEC 2.9.1.B 10.0 20.0 PERCENT OF OBJECTIVE 0.015 % 0.011 % l TOTAL BODY DOSE CRITICAL ORGAN DOSE l (MREM) (THYROID, MREM) l 2. 1-131 H-3 AND PARTICULATES WITH HALF-LIVES > 8 DAYS INHALATION

  • 1.42E-06 6.10E-05 GROUND AND FOOD
  • 1.29E-04 1.27E-02 TOTALS 1.30E-04 1.28E-02 TECH SPEC 2.9.1.B OBJECTIVE 15.0 15.0 PERCENT OF OBJECTIVE O.001 %

0.085 %

  • - HIGHEST OF INFANT OR CHILD DOSE FACTORS FC/ FORM /01

!-10

FC-421 l FORM REY. 1 02-13-88 i m' . FORT CALHOUN STATION UNIT NO. 1 R ) QUARTERLY CUMULATIVE DOSE CONTRIBUTIONS FROM RADI0 ACTIVE EFFLUENTS l QUARTER ' FOURTH, 196/ i A. tLIQUID EFFLUENTS: TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM) (LIVER, MREM) i MONITOR / HOTEL TANK 3.87E-02 5.43E-02 STEAM GENERATOR 1.08E-06 1.08E-06 TOTALS 3.87E-02 5.43E-02 TECH SPEC 2.9.1.A OBJECTIVE 3.0 10.0 i i PERCENT OF OBJECTIVE 1.291 % 0.543 % l i i B. tGASEOUS EFFLUENTS: O TOTAL BODY GAMMA TOTAL BODY BETA i DOSE (MRAD) DOSE (MRAD) 1. NOBLE GAS AIR DOSE 2.43E-05 4.50E-03 TECH SPEC 2.9.1.8 10.0 20.0 PERCENT OF OBJECTIVE 0.024 % 0.023 % I-l TOTAL BODY DOSE CRITICAL ORGAN DOSE i (MREM) (THYROID, MREM) 2. I-131. H-3, AND PARTICULATES WITH l HALF-LIVES > 8 DAYS j INHALATION

  • 1.28E-06 5.49E-05 GROUND AND FOOD
  • 2.20E-05 1.14E 02 TOTALS 2.32E-05 1.15E-02 TECH SPEC 2.9.1.B

( OBJECTIVE 15.0 15.0 ) PERCENT OF OBJECTIVE 0.000 1 0.076 %

  • - HIGHEST OF INFANT OR CHILD DOSE FACTORS t - STRONTIUM 89 AND STRONTIUM 90 DOSE CONTRIBUTIONS NOT INCLUDED BECAUSE RESULTS WERE NOT AVAILABLE AT THE TIME FOR THIS REPORT.

VALUES WILL BE UPDATED WHEN RESULTS ARE AVAILABLE. 1-11

1 J 1 a 1 i l l SECTION 11 i 1 ANNUAL OCCUPATIONAL EXPOSURE REPORT i TechnicalSpecification(5.9.1.b) i i i i i January 1, 1987 to December 31, 1987 i L f 1 i l 1 i l f I i l I I } r 1 2 1 I I' i t I I l 1 I f i r i i l 1 l I l 1 'e j II-1 l

l CMANA PUBLIC POWER DISTRICT FORT CALHOUN NUCLEAR STATION } PERSONNEL ACCUMULATIVE MREN RADIATION EXPCSURE I / TO DATE 1 1 1988 TIME 0000 WLMBER OF PERSONNEL AND MAN REM BY WORK & JOB FUNCTION Radiation exposures on this page are from self-reading dosimeter pencils NUMSER OF PERSONNEL GREATER TMAN 100 MREM TOTAL MAN REM STATION UTILITY OTHER TOTAL STATION UTILITY OTHER TOTAL WORK & J0S FUNCTION EMPL. EMPL. EMPL. EMPL. EMPL. CMPL. EMPL. MAN REM "* REACTOR OPER. & SURY. *" MAINTENANCS PERSONNEL 3 0 8 11 1.925 0.799 3.549 6.273 ENGINEERING PERSONNEL 13 6 25 44 6.920 2.176 7.764 16.860 SUPERVISORY PERSONNEL 1 0 0 1 0.890 0.023 0.003 0.916 OPERATING PERSONNEL 30 0 0 30 15.570 0. 0.038 15.608 HEALTH PHYS. PERSONNEL 22 0 51 73 23.231 0.005 30.417 53.653

  • " ROUTINE MAINTENANCE "*

MAINTENANCE PERSONNEL 52 30 67 149 25.466 13.043 40.648

79. 0 /

ENGINEERING PERSONNEL 1 2 8 11 1.094 0.875 2.183 4.152 SUPERVISORY PERSONNEL 1 0 0 1 0.217 0. O. 0.217 OPERATING PERSONNEL 0 0 0 0 0.143 0. O. 0.143 HEALTH PHYS. PERSONNEL 1 0 51 52 0.393 0.012 24.589 24.994 "* INSERVICE INSPECTION "* MAINTENANCE PERSONNEL 1 3 39 43 0.182 0.992 26.590 27.764 ENGINEERING PERSONNEL 1 0,- 0 1 0.490 0.065 0.205 0.760 SUPERVISORY PERSONNEL 0 0 0 0 0. O. 0. O. OPERATING PERSONNEL 2 0 0 2 0.450 0. 0. 0.450 [ HEALTH PHYS. PERSONNEL 1 0 2 3 0.200 0.005 0.955 1.160 \\

  • " $PECIAL MAINTENANCE "*

MAINTENANCE PERSONNEL 40 35 97 172 21.956 19.708 66.814 108.478 ENGINEERING PER$0NNEL 5 6 26 37 3.251 2.020 11.990 17.261 SUPERVISORY DERSONNEL 0 0 1 1 0.150 0.010 0.182 0.342 OPERATING PER$0NNEL 6 0 0 6 2.484 0. 0.005 2.489 HEALTN PHYS. PERSONNEL 11 1 29 41 9.527 0.143 12.785 22.455 "* WASTE PROCES$1NG "* MAINTENANCE PERSONNEL 5 4 6 15 1.686 1.496 4.423 7.605 ENGINEERING PERSONNEL 0 0 0 0 0.045 0.030 0.035 0.110 SUPERYlSORY PERSONNEL 0 0 0 0 0.030 0. O. 0.030 CPERATING PERSONNEL 3 0 0 3 0.943 0. O. 0.943 HEALTH PNYS. PERSONNEL 3 0 22 25 2.540 0. 21.887 24.427 '" REFUELING "* MAINTENANCE PERSONNEL 22 21 28 71 10.081 12.647 10.327 33.055 ENGINEERING PERSONNEL 9 1 11 21 2.046 0.242 3.301 5.589 l l SUPERVISORY PERSONNEL 1 0 0 1 0.500 0.020 0. 0.520 OPERATING PERSONNEL 23 0 0 23 5.510 0. O. 5.510 HEALTH PMYS. PERSONNEL 1 0 5 6 0.274 0. 0.908 1.182 n forgt we MAINTENANCE PERSONNEL 123 93 245 461 61.296 48.685 152.351 262.332 ENGINEER!WG PERSONNEL 29 15 70 114 13.846 5.408 25.478 44.732 SUPERYlSORY PER$0NNEL 3 0 1 4 1.787 0.053 0.185 2.025 OPERATING PERSONNEL 64 0 0 64 25.100 0. 0.043 25.143 HEALTH PHYS. PERSONNEL 39 160 200 36.165 0.165 91.541 127.871 l O "* TOTAL ACCUMULATION "* 258 10 476 843 f 11-2 l 1 -r

-~....... - - -.. -.. --....... - -.......... -... ~.. - c i , 9 NOTE: PERSONNEt MAY BE ACCOUNTED FOR Most THAN ONE f!ME SY RECEIVING >100 MREM on EACM or tw'or more work and job functions rotAL uumeen or Peas 0NwEt nECE'ivinG cREATER THAN 100 EaEM AT FORT CALHOUN STAT 108f Dut!NG 19l l: stat Qu Employees. utrLirr EmptonEs conteACT ANO ofMERS 172 70 ~ 339 l r 5 t f s l l i i i I, ~h .t R P ]. l 5 I i 4 l I II-3 l } __c-,,---,,

OMAHA PUBLIC POWER DISTRICT FORT CALHOUN NUCLEAR STATION PERSONNEL ACCUMULATIVE MREM RADIATION EXPOSURE TLD EXPOSURE RECEIVED AT FORT CALHOUN NUCLEAR STATION EXPOSURE R/.dGE REPORT WHOLF BODY TLD EXPOSURE NUMBER OF INDIVIDUALS RANGE (REMS) IN EACH RANGE No measureable exposure 89 Measureable exposure less than 0.1 706 0.10 to 0.25 158 0.25 to 0.50 116 0.50 to 0.75 75 0.75 to 1.00 69 1.00 to 2.00 99 O 2.00 to 3.00 21 3.00 to 4.00 3 4.00 to 5.00 0 5.00 to 6.00 0 6.00 to 7.00 0 7.00 to 8.00 0 8.00 to 9.00 0 9.00 to 10.00 0 10.00 to 11.00 0 11.00 to 12.00 0 Greater than 12.00 0 TOTAL NUMBER OF PERSONNEL - 1987 1336 NOTE: Individual values exactly equal to the values separating exposure ranges are reported in the higher range. Total station pencil exposura - 462.103 man-rem Total station TLD exposure - 388.488 man-rem O 11-4

) v 1 - l SECTION Ill RADI0 ACTIVE EFFLUENT RELEASES - GASE0US EFFLUENTS TECHNICAL SPECIFICATION (5.9.4.a) I r Table 1A Gaseous Effluents - Sumation of, All Releases Table 18 Not Applicable 4 Table IC Gaseous Effluents - Sumation of All Releases j. .O l. t July 1, 1987 to December 31, 1987 i i i t r e III-1 I b.-. __-_____.____.__...-__._.-,-,,,-.-.-.-_-,_,-,-._n,..,__.-,..,.-,.?

Radioactive Effluent Releases - Third and Fourth Quarters u) GASE0US EFFLUENTS Radioactive gaseous releases for the reporting period totalled 36.5 Curies of inert gases. Averaged over the third and fourth quarters of the reporting period, the gross gaseous activity release rates were 1.41E+00 pCi/Sec. and 3.18E+00 pCi/Sec., respectively. Radioactive halogens and particulates with half-lives greater than eight days released during the reporting period totalled 9.04E-05 Curies. Averaged over the third and fourth quarters of the reporting period, the t halogen release rates were 5.96E-06 uCi/Sec. and 5.33E-06 pCi/Sec., respectively. Averaged over the third quarter of the reporting period, the particulate release rate was 7.76E-08 pCi/Sec. Averaged over the fourth quarter, the particulate release rate fell below the analytical Lower Limit of Detection (LLO) and is reported as "0". Radioactive tritium released during the reporting period totalled 9.85E-02 Curies. Gross alpha radioactivity released during the reporting period totalled 2.46E-06 Curies, l I 111-2

f') b TABLE 1A EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JULY THRU DEC 87 3 QUARTER 4 QUARTER NUCL10ES IN CURIES CONT OECAY RM060 TOTAL CONT DECAY RM060 TOTAL A. FISSION & ACTIVATION GASES TOTAL RELEASE CI 1.08E+01 4.18E-01 0.00E+00 1.12E+01 2.52E+01 1.09E-01 0.00E+00 2.53E+01 AVG RELEASE RATE FOR PEH100 UCI/SEC 3.36E+00 5.26E-02 0.CDE+00 1.4tE+00 3.17t+00 1.37E-02 0.00E+00 3.18E+00 PERCENT OF LIMIT TECH SPEC e NONE 8. IODINES TOTAL RELEASE IOOINE - 131 CI 0.00E+00 0.00E+00 4.74E-05 4.74E-05 0.00E+00 0.00E+00 4.24E-05 4.24E-05 AVG RELEASE RATE FOR PERIOD UCI/SEC O.00E+00 0.00E+00 5.96E-06 5.96E-06 0.OOE+00 0.00E+00 5.33E-06 5.33E-06 PERCENT OF LIMIT TECH SPEC = NONE C. PARTICULATES PARTICULATES WITH HALF LIVES.GT. 8 OAYS CI 0.00E+00 0.00E+00 6.84E-07 6.84E-07 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 AVG RELEASE RATE l FOR PERIDO UCI/SEC 0.OOE+00 0.00E+00 7.72E-08 7.72E-08 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 i PERCENT OF LIMIT TECH SPEC a NONE GROSS ALPHA RADIOACTIVITY CI 0.00E+00 0.00E+00 8.17E-07 8.17E-07 0.00E+00 0.00E+00 1.64E-06 1.64E-06 D. TRITIUM TOTAL RELEASE CI 4.52E-02 0.00E+00 0.00E+00 4.52E-02 5.33E-02 0.00E+00 0.00E+00 5.33E-02 AVG RELEASE RATE FOR PERIGO UCI/SEC 5.68E-03 0.00E+00 0.00E+00 5.68E-03 6.70E-03 0.00E+00 0.00E+00 6.70E-03 PERCENT OF LIMIT TECH SPEC = NOME 11l-3

[ s\\ i i \\v/ =Oo0=-C0-o-~ @ TOT 000000000000000000 Nc 000000000000 0000 0C000000000000000o J + +++ i + + s + i + s i +e + + ++ +++ + ++++++++++ C. o WWWWWWWWWWWW WWWW WWWWWWWWWWWWWWWWWW W W' E ocoocNoo@o@M TNOT 0000o00000o0000000 MT U C-T. Q. Q. o. N. O. C. C. C. O. c. c. N. @. c. o. C.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 M. @ 4 p NCOO=McC=o@N 9900 0000000000000000o0 c= c O6 o00000000000 WTOW C00000000000000000 Oc w C0000o000000 0000 0Q0000000000000000 00 g C ++ ++++++++++ 8 i + e + + ++ +++ + ++++++++++ +t c WWWWWWWWWWWW WWWW WWWWWWWWWWWWWWWWWW WW oo000000000o TNov Q00o00000000000000 09 b Q 0 0 0 0 0 0.o.0 0 0 0 N. W. O. O. C.0 0 0 0 0 0. C. 0 0 0 0 0 0 0 0 0. o.

c. c.

O g 2 00000000C000 T900 00000000000000000o Q= W C E cO000000-00= 0000 000000000000o00000 CO O 4 000000000Q00 0000 000000000000000000 00 3 > a +++++++ a + + e ++++ + + +++ ++++++++++++ + ++ M O < W W W W W W W WJ W W W W WWWW WWWWWWWWWWWWWWWWWW WW u Nococcoomoom occo C0000000000000000o oo T W 000000000000 o

0. Q. 0 0 000000000000000000 00 0

g @c000000 C000 000000C00000000000 CO -O00==CC0C== 0000 000000000000000000 NO M C00000000000 0000 000000000000000000 00 M W ++++s e + + + + a + ++++ + + ++ ++++ ++++++++++ t + b M WWWWWWWWWWWW WWWW WWWWWWWWWWWWWWWWWW WW O k Z occocNocco@N 0000 000000000000000000 Mo a E W o T. O. Q. Q. N. o. o. c. c. o. e. d. 000000000000000000 M. Q. g Q000 C J V a W N NOCC-MOCOQWN C000 000000000000000000 40 g t C = = J 0o00==00-O== @vot c500000000000000o% NN cO J J U 000000000000 0000 CC00000000000Q0000 00 eV W W + +++ e s + + 6 + e o e s + e +e ++ + ++++ ++++++++t i i 4 c M Q WWWWWWWWWWWW WWWW WWWWWWWWWWWWWWWWWW WW O E @oco@TooeomN Toom ovooooooooooooooot NN e o [ a O 3 o g 3 y

e. c. o. O. O. N. C. Q. W. o. =. =.

N o. o. T. Q. 0 0 0. o. 0 0 0 0 0 0 0 0 0 0. c. =.

d. =.

M ( T @COQaNOCMO@= Tece Q@C00000000000000@ Te E u O O % O w = = cL - W C00000000000 cTOT ONCOcocococooOOOON ch W > J 000000000000 0000 000000000000000000 cc Q J M 3 o +++++++++++ + e s+1 + 1 + ++++++++++++++t +t 3 4 ) 7 WWWWWWWWWWWW WWWW WWWWWWWWWWWWWWWWWW WW gg < 3 a oooooooooooO Toom oToCocooOOooooooOT os .y a A E C. 0 0 0 0 0 0 0 0 0 0 0 N C. C. T. C. =. O. 0 0 0 0 0 0 0 0 0 0 0 0 0 0. =. O. m O 'O O e o g g Z M w W C00000000000 Teos O@Q00000C00000000@ Qe 4 U k k Z J K @ WL e W 4 NOOOOOCC=OO= 0000 0000000000C0000000 00 g Z 3 3 3 000000000000 occo C00000000000000000 00 -c W J Z O > a +++++++e ++a ++++ + + + +++++++++++++++ ++ 3 L Z WWWWWWWWWWWW WWWW WWWWWWWWWWWWWWWWWW WW gO J E M U @ocoOQoCmoom 0000 o0000Co000000000oo oo 9 E E W = W N. Q. Q. C. Q. Q. O. C. d. o. o. =. C. 0 0 0 000000000000000000 C. o. "e 3 6 3 o W M W @CCCCCCCMOOT 0000 000000000000000000 00 CV 3 M > 0 .3 o000==C000-= 0000 000000000000000000 No M 000000000000 0000 000000000000000000 00 + +++ l e + + ++e + ++++ + + + + + +++++ ++++++++ t + p> Q WWWWWWWWWWWW WWWW WWWWWWWWCWWWWWWWWW WW OO Z ocoo@ToCoo@c ocoo oooooooooooooooooo No C b o

e. c. o. c. Q. N o. c.c. o.. o C.000 000000000000000000 40 a

v g QQco-NCCOO@= C000 000000000000000000 TO p e ma 4 3 = Mm M J Cm l W Le = 3 a o o OM L 3 0 . *o OM ow u M = 000= w6 6 =O W 2 >>>zM 22 20 E au Z M W UUUWW@Oha T AT W b" = 4 3 a &>e@ d = a 4 9 3 0 m3c3 N m3 -Me t e # =MONT a ea va 4 3 m M Me-eMme@ec 5 MMMEJ33MMTMMcWOM39T 3 CT O W ZMcMc MM s M I M=OM===O333=====@M@-3==Z 03 J L Q Q=Z=Z==Z=ZavnW e e I mW==a e e i e iW e 4 Z8 8 W@@t334 g = = t ol ot d $525t55'O'os s ZWWW =>>WW33 =D t5t*b>is***it!555""=gkZwW<g3Oc@# *i"5 ="*iai:~a p o 'm OOOO><maccaMMeNe 3 =Z>Z>ZZ>Z> ZK2JOZwaac 3 8 Z kWEW2WWmW2W20=OOOOa>>OO<WWOgo <WW a=Q>2q Om XXXXXXEXXX<>

===> MM==CWV4aVmJWW =N> MV WQ 55 t n 6\\ l l

l l O SECTION IV RADI0 ACTIVE EFFLUENT RELEASES - LIQUID EFFLUENTS TECHNICAL SPECIFICATION (5.9.4.a.) Table 2A Liquid Effluents - Sumation of All Releases Table 2B Liquid Effluents - Sumation of All Releases O July 1,1987 to December 31, 1987 O IV-1

1 Radioactive Effluent Releases - Third and Fourth Quarters ' - Q; LIQUID EFFLUENTS During the reporting period, a total of 5.12E-02 Curies of radioactive liquid materials less tritium and dissolved noble gases were relea.ed to the Missouri River at an average concentration of 1.50E-10 pCi/ml. This represents 1.5E-01% of the limits specified in Appendix B to 10 CFR Part 20 (1.0E-07 pCi/ml) for unrestricted areas. Dilution water during the period amounted to 3.44E+11 liters, while radioactive liquid waste volume was 5.49E+07 liters. Additionally, 62.7 Curies of tritium were discharged at an average O concentration of 1.92E-07 pCi/ml or 6.38E-03% of MPC (3.0E-03 pCi/ml). Gross tipha radioactivity released during the reporting period totalled 2.54E-04 Curies. 4 IV-2 ~ --__m-

A) \\ g

    • /

- :p v ki[;! av } l' TABLE 2A I EFFLUENT AND WASTE DISPOSAL REPORT I ALL RELEA5CS

1 LIQUID [FrLUENTS-SUMMATION OF SEMIANNUAL FOR JULY THRU DEC 87 3 QUARTER 4 QUARTER A.

FIS$10N& ACTIVATION PRODUCTS TOTAL HELEASE (NO 2.50E-02.2.62E-02 TRITIUM. GAS. ALPHA) C1 l' I AVG DILUTED l.36E-10 1.64E-10 CONCENTRATION UCI/ML PERCENT OF LEMET 10 CFR 20. APP. 8= 1.GE-0T t.36E-01 1.64E-Ot j B. TRITIUM t.04E+09 5.23E*01 TOTAL RELEASE CI AVG OILUTED 5.64E-08 3.2FE-07 CONCENTRATION UCI/ML PERCENT OF LIMIT IO CFR 20. APP. D = 3.0E-03 1.80E-03 a.09E-02 C. D1550LVED& ENTRAINED GASES i TOTAL RELEASE CI 6.10E-03 8.00E-03 AVG DILUTED I 3.32E-st 5.06E-tt CONCENTRATION UCt/ML Due to typographical error, current PERCENT Or trM T 4 1ECn SPEC - 2.0E-0A UCi/Mt s i.66E-05 2.53E-05 ML Su 6 WsiW m. shown in millicuries / milliliter vs. o. Gross ALPnA RAoioACTivrTv miCTOCuries/ milliliter as, Correctly 1.03E-04 .5IE-04 TOTAL RELEASE CI shown here. An "Application for. Amendment of Operating License" i E. votuME or WASTE RELEASE correcting this error was f.iled 2.79E.or 2.70E.07 under 0 PPD Letter LIC-88-087 prior To o L. t TERs F. v0tUMe oF oituviON wATCR dated February.8,.1988. ~ I.84E+t1 l.60E+11 THIS PERIOD LITERS e IV-3

I l l J I /^% ' '( ) %d 0C w O W .Q e.Q e mm b me-O w >-T 4 We C >E 30 m M 4 *wE OMw O C b 3b Om% M 10 W W WL4 e m b a 3 CD e M-mW W4 i U LwmW 4Qb be OC EC we 3O b e a @%M 3 3 OC CT OT Wb W 4 EMt 4eMe bW 3 LO OM C b 6m% a [ COCOCOOOMOTOMOTMMTCOOMMOOMTOCON MOM e=C= ~4 C000000000000000000000000000000 000 0000 " O. \\ Z + + e + + + + + e + i+ e + e i s e +++ e i + + e e +++ e e + i i +++ i Y U WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWW WWWW WW OO=OOOOOOONOSO@=@~OOOd@OOMNOOON mom MNON Q@ C.O.@.Q.O.O.Q.Q.M.Q.e.Q. @. Q. @ @.~. C. Q.Q. O. c. N.Q.Q.@.N.C. O. O.C. 000 N. N. O. N.

c. =.

g e W CO@GOOOOMOMOTO=am@ COO==CONNCOON

  1. 0@

@@Ce TN E< C000000000000000000000000000000 000 c=O" N@ 3 0000000000000000000000000000000 000 0000 O "a O > + + +++++++++++++++++++++++++++++ +++ e e + a e M Z WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWW WWWW WW W W O 0000000000000000000000000000000 000 m@O@ em W M u C.000000000000000000000000000000 000

e. T. O. W.

O. N. g O W N 0000000000000000000000000000000 000 @=O= NM L J e W W E E 9@COOOOOMOOON@cMM90 COT @OOMCCCON -MOM N=O= M@ U C000000000000000000000000000000 000 0000 =O J J W Z e e++++++e +++ a e a e a i +++e a + + s ++++ l e + 1 e +++ 6 e J O U WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWW WWWW WW M N = O O O O O O " C O O v @ @ @ C @ O O O M t* C O @ O C O O @ C00 NMOM N@ O 3 4 O.N.O.O.O.O.O.O. c.Q.O.O. c. c.@. @.@. @.Q.O. O. v.=.C.O.N. O. O. O. C.T. =.Q.=. 9000 = O. a w E g a M O Z W NOOOOOOO=OOO=@e@M=000MaCONCOOON @OC t=O" = D C Z E N O Cwo000000000000000000000000000T 000 WNON NO W = J 3 0000000000000000000000000000000 000 0000

== W > 3 0 > + e ++++++++++++++++++++++++++++e +++ e a+e e s J M 4 7 Z WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWW WWWW WW e 4 M O CN0000000000000000000000000000N 000 M=ON WN < 3 E u 090000000000000000000000000000T 000 Q@o@ @v O C M 0' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 0 0 0 0 0 0 0 0' 0 0 M = *

  • * = -

=

  • * * * * * =
  • * =

O M L 000 = MOM =M Z e I M J 3 = J Z 3 I Z W Z M = W D E W E = 3 J = U J w = 2 O MM O 40 3 m . 6 3 3 O WW O d 30 m W W v 3 = MM = 3= 2 W M M O E (< E 42 = 0 2 @O O e T 99 O O @W 00 W I OW = = em e e = = m "N N3=mNa 4 4 Na e 3 e e 33= @= MOI N iew ee i=9*0sN= OO J U C M 33N339 3342==33'MMT3MS@MSWM C3I w*~3e 8 2 WW Mes 4

  • E Z

= W

==~3=3e =eMa @D>=>=33>O >Z MMO WO O J O

==sW> eNDI e ew i nge eW eSeeZZeZI ~3Zw J=

==w Scw v 3 >>>OW3==WW3ZIZ23>Z3d@><030EZwo 04 e i E D 3 = J ZZJCZ3-3ZZ3W3O=3J43e a JZ333WWZ3J ME ZZJ W <=MJ U OO<>I=I O===Imum=<O= Eve >===>Iwa< M> 004 I I>M4 O- <= i Ik 3 EECJUEZEQOE>MECMCZMOZeZ>E>J>J>> =Z ZZ> = a=Ok > am Z >>OOWW=IQQ43Wa=Wo*WE=O4ZWZ-3WZO OW WWC O JERO JE MMUS>UWUa=CEUNZvu3WmNUJ4v4MEM4> xx> <>Ok 94 I

SECTION V RADIOACTIVE EFFLUENT RELEASES - SOLID RADI0 ACTIVE WASTE TECHNICAL SPECIFICATION (5.9.4.a.) I July 1, 1987 to December 31, 1997 V-1

~ (> RADIQACTIVE DTIUDir REIEASES - SOLID RADIOACTIVE WASTE EFTIUENT AND %&STE DISPOSAL REIORT July 1987 through December-1987 SOLID NASTE AND IRRADIATED FUEL SHIIHENTS A. SOLID NASTE SHIPPED OFFSITE FUR ERIAL OR DISPOSAL (Nor IRRADIATED) Month Number of Volume Curie Est. Ibtal 1. Type of Wasta Shicoed Shitznants Cu. Meter Content % Error a. Spent resins, July 0 0 0 N/A filter sludges, August 0 0 0 N/A evaporator September 0 0 0 N/A bott ms, etc. October 0 0 0 N/A November 0 0 0 N/A nr. = M 0 0 0 N/A Six Month Ibtal (Type A) 0 0 0 b. Dry c m pra* W, July 0 0 0 N/A contaminated August 0 0 0 N/A equilanant, etc. September 0 0 0 N/A October 0 0 0 N/A November 0 0 0 N/A December 1 16.99 1.637 20 Six Month Total (Type B) 1 16.99 1.637 c. Irradiated July 0 0 0 la W Tents and August 0 0 0 other categories September 0 0 0 la October 0 0 0 la November 0 0 0 la _ h _r 0 0 0 la Six Month Total (Type C) 0 0 0 d. Other July 0 0 0 la August 0 0 0 la September 0 0 0 NA October 0 0 0 la November 0 0 0 la narwnber 0 0 0 la Six Month Ibtal (Type D) 0 0 0 l V-2

( % RADIOACTIVE EFFLUDE RELEASES - SOLID RADIOACTIVE \\ NASTE EFFLUDC AND WASIE DISPOSAL REPORT (Continued) B. ESTD9CE OF MATOR NUCTTm COGOSITICH (By Type of Waste) 1. Percentage of curies frca Represented Isotopes Isotope Pertent Curies a. No Shipments N/A N/A All other nuclides constitute less than 1%. b. Cs 137 67.9 1.112 All other nuclides Cs 134 14.5 .237 constitute less Co 58 16.5 .270 than 1%. Co 60 1.7 .028 c. N/A N/A N/A d. N/A N/A N/A C. SOLID (DSTE (DISPOSITION) Number of Shirnants Trarscortation Mode Destiration 1 Closed Sole Use Vehicle Richland, Washington D. IRRADIATED NEL SHIINDES (DISEOSITION) Number of Shirnents Trarscortation Mode Destiration 0 N/A N/A O V-3

RADI0 ACTIVE EFFLUENT RELEASES - SOLID RADI0 ACTIVE WASTE EFFLUENT AND WASTE DISPOSAL REPORT (Continued) PCP AND ODCM CHANGES FOR THE PERIOD JULY 1, 1987 - DECEMBER 31, 1987 In accordance with Technical Specification 5.9.4.a, the radioactive effluent release report shall include any changes to the Offsite Dose CalculationManual(00CM)andtheProcessControlProgram(PCP). A change was made to the ODCM. The nuclide Ru-106 was added to Table 1 of the ODCM. The values for ingestion dose commitment factor for the adult total body, and critical organ (liver), from liquid effluents, are presented in this table. O No changes were made to the PCP during this reporting period. O V-4

J' O SECTION VI JOINT. FREQUENCY DISTRIBUTION WIND DIRECTION VS. WIND SPEED BY STABILITY CLASS AND METEOROLOGY DATA PER BATCH RELEASE. (Regulatory Guide 1.21) July 1, 1987 to December 31, 1987 O VI-l

JOINT FREQUENCY DISTRIBUTION WIND DIRECTION VS. WIND SPEED BY STABILITY CLASS AND METEOROLOGY DATA PER BATCH RELEASE A. Meteorology data per batch tables will have -99 values signifying either invalid data or no data available. B. Meteorology Data Recovery All key parameters were sufficiently recovered. There were no weather data which needed to be replaced. O f l l i i O VI-2 r l t

r 4 m,- E C.0 0 0 0 0 0 0 0 0 0 0 9.@.C.N.@. <m 3 OOOOOOOOOOOONNOWT J 4 O-0000000000~-ONC 0m OO6 OOOOOOOOOOOOOOOOO + > Z. O >O @ OOOOOOOOOOOOOOOOO E O e CD E O O. y W A 00@ 00000000000000000 C. W N N M 2 O W > m 00@. O-COOOOOOOOOOOONM W 3 2 Z O = O

0. e- @.

0 C0000000000000000 O y W 4 is t 7 I A O D. >O @. OOOOOOOOOOO%CoOOOO w O W .Z.e M 4 9 Id 3 2 rN e M N = 3 O ) g 4 g C. 0 4. y 00000000000000000 w s 8- % s, a < u A > c W T T W G = Z = g C O 00@ M 0 00000000000000000 W = V W M M W W a U 2 W q> 0 V 6 004 000000000r'0000000 Z u. 2 O W < n M O Z 3 3 = 0 > w 3 W C - - - - =. - * - = * * *. **. 2 2

4. *0 @*

0000000000000-00= N N. Z Z w 3 O Z N N O 3 a Z O m. 3 O. O T. 000000000000-000-m C E U 2 W >= M N =* 3 = 2 N N Z M 0.e Z N a

== O A O O O n ~

  • >==

C >= 0 DO@ C0000000000000000 4 t Z

  • > =
  • 4 r

o 0 2 = = - 3 W 2 t U Z N e W t [ W e e ................. c d C. O T 00000000000000000 O O i 3 3

== l O Z O e e-Q 0 2 >- O W e I U= 2 O O

== 0 as > w O J =. g( y J N W 40@ 00000000000000000 > < l @A .Z. O

  • > =.

.E O O 02 O E = 4 7 E O O gW O. C T. 00000000000000000 O W.J [ 3v 2 Z l N O3 O O W W \\ O LZ D U l 4 2 2 O UZ 3 W 1 0== 3 Z a ./_N l

== JO 2 } m 3 OI O J l k W DJ s"/ a a< v W W W W i i 3 m.- l V W ZWZ MWA AEA Z3Z O W 4 ( A ZZWWWMMMOA333ZZZW .J I> 1 o 4 4x l 4 0 30 l 06

4 G

4. N. *t. @. o. CD. T.. o. o. O. @. N. N. N. N.

c0 3 N--No@NMOOONNNMNM J 4 M--No---COONM@vNN M O> oOw 0 0 0 0 0 0 0 t) o 0 0 0 0 0 0 0 0 WZ = OO@ QQOOOooooooooOOOo g O <D w o O V W C0@ 000000-000000000-o. A N N M 2 o W 00@ 00000-0000000000-W 3 3 Z o e C. o @ 00000000000000000. O 0 3 W c e W I 4 I a ocoOOCCOOOOOo-NOM O

c. c :).

O u 5

g. _

u,3 Z 1 q g 3 Z / \\ l = 4 ? j, x. _./ M

  • OO9 oooooOOOOooOo0-C-

== 3 .O 5 g m 4 U e > c W v v W 3 Z a = o O W = 40@ 00000000000000000 Q O W M M W W V f a 3 W r 0 0 6 004 COO-Coo-Coco-Ococo Z A => 3 O W M M l C .Z. 3 i a o > w 3 W O NOC-cCooOOONNMMN@ O O a Z @C@* Z Z w => 1 3 O Z N N r a

== Z O i > = i N 3 .C. U C09 -o000000000000M09 e 2 W A a N N Z A 2 O Z i z - i I 0 M O o

== O m s O > 0 00@- O--QQOOOOOOOONCOT 4 l .Z 3 o N. U 3 W 3 M W I Z d w i e ................. O m 3 3 =, COT 00000000000000000 Q C o Z o u 0 O 1 MO a 2 Q I U= 3 o o

  • =

J

== > = = > W. o U 4 J 24 N W 40@ C0000000000000000 > < Z MM Z O A +> +

== ~ O O ~ Q2 O w w o 4 7 O gW o Wd 009 00000000000000000 RU = > < E Z N O3 o o W W O aZ 10 v C I 2 O UZ 3 W CN t o== 3 2 4 'a JO G m k 4 O 3 CI O J .= s' / o W ps i.m 4 V W W W W 3 3 3 3 U W ZWZ AWA eEM Z12 O W 4 4 M ZZWWWHHAAMEEEZZZ> a Ik Q 4 43 4 0 30 Ow

?< '. / 2 CD. o. @. M. @. m. 4.. N. o. O. 9 9. @. @. N. N. <c 3

  • N-NNDDDMMONNNNNM

_J i T M @ O N N @ N

  • T o== M N * * -

-Ne@ l O l Ooa ooooooooooooooooo I >Z ~ \\ ooooooooooooooooo O. o @ a o O CD E o o. y W Co@ cocoo--Nococcoo-o Q

  • > =

h M E o W ococoNCacocooccooN M 00@* W E-o I .Z. o. O

c. o m.

ococoN-Nococoo-oc O E W d W 9 4 t e O

c. o c O?ooONNoooooooNo@

X 0 W [N W 7 e T T \\ o Z LO 3 O g gN~j g

o. c t.

cococo--COOOON-o@ ee s t H e < U > Q W T T W E w Z w 1 o o

c. o @

cooocoo--TocoNNoo W

== ~ e 0 V U M M W W U a 2 W Q U w 009 ocoo-Co-coccoNMoh Z w 3 O W 4 M M o Z 3 0 > 2 = 6 3 W o Z Z w - o N. E Z 40@ co-MocoooccoNa@@c 3 o Z N N T .Z o. C ~> e N 3 -NNaococcoo-oMT-4 5 Q Q T. C U - e = W 3 ~ 3 N N Z B o Z l me = 0 o A O .. * * * * * * * * ~ n

    • O N o - ~ ~ C Q Q' o c o o - N M N M C e O 40@

Z 2 o > e = = ~ U E W G A W Z ~ ................ c e W l e 3 3 >= 004 ---000000000000-9 o eo o Z o a 0 2 >c W 2

0 I v

2 o o J =.=4 o. > w h W 400 00000000000000000. < y g( Z > e.* M Z O e a =a e 0 o

== L = Q3 o w o I 7 o gW

o. c t.

C0000000000000000 k o W.J 2 2 BU N O3 o o W W c v o 4Z U 3 m 3 W ( 0 VZ 2 4 i o =3 j Jo 2 (s = 2 OI o J b W 3.J 4 4< U W W W W 3 3 E E ~ v W ZWZ AWA eBe ZBZ o W 4 A 2ZWWWAAAMOEEEZZZ> .J Z> c ( at g 4 Q o w

. ;Q \\ A.,) - E . m.O. M. T N.e. e. @. o. N. *. >. = M.N.@. T. 4e ,3 =NNNMMTTTMNaNNN=M ~J' 4 El N T @ N N O c0.- N o M @ @ M O e - > =

==NC@==NN

  • TNTT O

== = N ............... e. OOE oooooooooOooooOCO

  • >E
  • e 00@

000000=Q00000000= 2 O e e w oO .U C. >o @ CooCO-@@NoOQOO-O@ W

o. '

M N N j.f a E O W i. W. e 00@ oco-o@eNNooooooOM p 3 T 'D E .Z. C. O C. o m. CCoome@C@ coo-coo @ O E NM= m W W W. I CL i A O D. O @ CO=C@@T@M@cooO@oc 2C O wJ. ,W 2 A T T t

    • 4 2

= E O 'O a < = e O >O T= o c o - co N T T N M c C = M C O M i ( U p

== M >. O w T-T W E e E se a O O d 0 = O - C @ e = @ tD M O O C M @ o c W

== @O@ U W M M W W U 4 .E.e y W q O O T. ON-TN.OCT@TNoc@TNo 0 U w 2 s e

e

n o g gW 4 M M = 0 k 3

== 6 E W O ........ * * * * =.... = 2 2 m - 2 @ O m. ~ ~ Q N W @ N @ C W N - - T cD e N c. 2 N e 3 0 2 N N T E

    • 2 O.

M me p. 3 e. T. U Q C T. @N@a@=MN@@NOTTMme e e W . p- -N M e = 2 = z N N Z A .O Z N t C Ae O .o a M Q N O > O C. O @ NTT@@=NNM-Ma@eQTo O

=

Na@ 4 K 2 U . E W 3 2 o W W O W s m ................. e m 3 3

== 009 TMNMMOC=-O--MN@NN O e O Z O a T o 0 g MO W 2 - = Ua 5 O O = 0 s> => u. o > J== g4 - y .J N W @O@ A000000000000-=ON 4 Z e MM Z Q M O o = = QE O E O 4 7 o = gw .......,........ e o W.J C. O T. 00000000000000000 N U 2 2 8 3 O O W W O E U Q. 2 O Ut W I O ** 2 4 = J E e 5 9 O J W p.J

    • 4 a4 U

W W W W 3 3 3 3 > U W 2WZ MWM MEe 233 O W 4 4 e 2 2 W W W e @ @ H M E E E Z Z 2 P- .J 1> e ( g 4 Q Q m

..l <~s(; s" ~s ]: ...U.J \\. A 4 1 1 j TABLE 158 - E 1 j DATA PERIOD 07/08/1987 THROUGH 09/30/1987 RUN FROM. TAPE SEEEES TRI-EM OesAHA PUOLIC P0wER DISTRICT FONT CALHOUN NUCLEAR STATION JOINT FREQUENCY DISTRIBUTION WINO DIRECTION VS. WINO SPEED IN METERS /SEC FOR-0T100 = -0.4 TO +1.5 IN FREQUENCY DATA USEO -- WD10.wSIO.OT100 SECTOR 15 WINO DIRECTION NOT AFFECTED OIRECTION I i O.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 6.0 7.0 8.0 9.0 l SECTOR TO TO TO TO TO TO .TO TO TO TO TO TO' TO TO TO TOTAL USAR l 0.4 0.9 1.4 1.9 2.4 2.9 3.4 3.9 4.4 4.9 5.9 6.9 7.9 - 8.9 INF NME 0. O. 5. 5. 1. 1. O. O. O. O. O. O. O. O. O. 12. ~1.6 NE O. O. 1 2. O. 1 1 O. O. O. O. O. O. O. O. 5. 2.1' ENE 0. 1. 2. O. 3. 1 1. 1. O. O. O. O. O. O. O. 9. 2.1 E 0. 3. 6. 6. 3. 7. 6. 5. 1 O. O. O. O. O. O. 37. 2.3 I ESE 0. 5. 8. 13. 15. 4. 6. 5. 5. O. 1. 1. O. O. O. 63. 2.4 i SE 0. O. 8. 14 14. 16. 25, 18. 6. 4. 5. 5. O. O. O. 113. 3.1 i SSE O. 2. 4 1. 9. 12. 25, 28. 30. 24 25. 31. O. O. O. 164 4.0 j S 0. 3. 3. 4. 5. 7. 14 11. 14. 17. 23. 5. O. O. O. 106. 4., 0 ' S$w 0. 1. 1. 8. 3. 6. 2. 3. 7 3. 5. 5. 1. O. O. 45. 3.7 Sw 0. 2. 5. 1. O. 4. 3. O. 3. 1 3.. 4 O. O. O. 26. 3.4 WSW 0. l. 3. 1 3. 5. 2. O. 3. 1 O. O. O. O. O. 19. 2.6 w 0. 6. 9. 2. 2. 2. 2. 1 O. O. O. O. O. O, O. 24 1.6' www 0. 12. 34 7. 5. 5. 1. O. O. O. 1. O. D. O. O. 65. 1.4' i Nw 0. 7. 45. 35. 16. 3. l. 2. O. O. O. O. O. O. O. 109. 1.5 NNw 0. 5. 58, 23. 33. 14. 7. 1. 1. O. O. O. O. O. O. 82. 1.9 N 0. 1. 5. 6. 4 1. 4 O. 1. O. O. O, 0. O. O. 22. '2.1 j ] TOTAL O. 49. 157. 128. 96. 89. 98. 68. 71 50: 63. 33 1. 'O. O. 901. 2.8 1 I NUM8ER OF INVALIO 08SERVATIONSs 3, J q PERCENT OF VALIO OBSERVATIONS = 41.6 4 l l 1 j VI-7 1 t 7 4 i . -.., _., _..~.,., - - -... -,...,. -.. - _ -... ., + . -.- - -, ~... ~.

.p. t --y ~~ _ -n .-a n

1 2

5 1. , rh. 1 J{% f - d. ) .E 4 - @ e.W.W.@.M.@. o. @.=.N.o.o.N. e.@.@. g 3 - coa *=NNMMN=====Ca j d 1 J 4 --TwNehe@e-ovNNMo NMNNM*=MMM N O M + - O. c t o0000000000000000 1 WZ + O. o @ ooooooooooooooooo g p.. O e e j w oo u W k 00@ 00000000000000000 c. W =>

  • N N

M o Ew M C0@ C00000000-000000* 3 W a 3 .Z. o. O oc@ cocococoNoo*30 Coon o 3 W d w i a t M O co@ 000000c*N-0C00-oo X o.W => a M Z H T T 3

    • 3 E CO 3

' O z a C. 0 4 00000004.0000000c w A ( O = p M > c w T T W 3 g m o o

c. o @.

ococoNT@NocococoN M M Q N U w M M W W a u a > w 4 c u s 009 ococo=eMNNoocacok 2-E =>

  • 3 o u 4 M M o

2 3 m aa o k m 3 w o

==************** a Z

c. o @

coco-T@MMMooooooo T e Z Z w M 3 o E N N w 2 o E

== c. 3 e e o u CCT con =@bMM-=ococooT a a W

  • > =

N H d 3 9 2 N N Z M > + ** O E

== 0 o M o M

    • o o > c

@C@ o c o c c h a - O'N T M @ M'o c h 4 Z M o

    • =

a 2 3 w g U Z .= A w O w + e ................. e M 3 3

    • COT ao-N@Maa-MTo@o@==

0 C o E o n => * ~NN C c 2 >0 W E

3 o o

    • O f.

U.*.= J ** o n= w y ( .J g( N >> > > w co@ c--o**TM@@MNoe-N= W HW Z o M

  • a N

Z

== o o og C E = 7 E o gw ................. g

o. o T.

00000000000000000 o WJ 2 2 v N 3 o o W w o E V 4 5 e o Ut u 4 o== 2 & ma J q E o J w .J 4

  • 4 U

W W W 3 3 U W W2 MWM MEM 3 o W 4 M EwwwAMWMMBE E 2> J 8 4 E 4 o o b

t i sx- / '\\ 5 i e E - O.Q..O.N.T.@.T.@.~.M.o.e.O.@. e. 4e 3 UCO-Ne=eNO*N=C*D= J 4 NCON@TccTM@TTNaNM g H -- O. 6 oOw -ooooooooooCQooaN >Z i d'

o. O @

OOOQQOOCOOCoooooO g O e e b. O u - O W -> oO@ ooooooooooooooooo m o = N N [ M E O w - i M 00@ 00000000000-000C= a W E t 3 Z o t C C. 0 @ C000*O0000000000~ \\, O 3 w w I CL i w O CO@ 00000000000000000 X 0 W => - W 2 O T T 4 _3 Z Ch 3 .O g i g O. C T. COCOOOO--COOOQcoN w. b + D-H 4 0 M > Q W T T w 3 = g E o Q WO@ C000000C*-Q0000C0= W

== W Q U w M M W W U A 3 q > w Q C T. 000000~c00000000* Q U w 3 3 O W 4 M M O 2 3 O

  • 3 w

3 w Q E 2 00@ C000000000000000o o Z Z w 3 o Z N N N 3 = Z .O. > = N 3 C. O T COQQNocoOC=COOCOM e e a w U M w = Z W N N 2 M 2 O. E = G m. .s > + .O M O o O n 0 > 0 @C@ QQOO*-ONCOOcocOOT 4 > 4 .Z E O > = w s 3 U 9, .................d w Z 2 A e e Q w 3 3 = 009 QQQNc=T--NM-N=-CT o e O 2 O n M O O m >0 w z - * = 0 g C O Z U.== J== O, u. m J y g(

N b

W @O@

  • COCONO*--NNN-O-T

.Z 2 O A MM 0 C ea = m. QE O = E O 4 7 ................. o gw o WJ' OCT C0000000000000000 2 2 U h 3 O O W W U O 3 E O w 8 UE 3 6 rs e m / J q J l e M V e w J t-M Iz5WONue039.g g >S W W W W E B = & 4 U Biz W J e 4 5 4 O O w

[* * ) ~ \\ ) \\ ) NJ v' N,_,,' TABLE 158 - ALL DATA PERIDO 07/01/1987 THROUGH 09/30/1987 RUN FROM TAPE SERIES TRI-EX OMAHA PUBLIC POWER DISTRICT FORT CALHOUN NUCLEAR STATION JOINT FREOUENCY DISTRIBUTION WIND DIRECTION V5. wlND SPEEL IN METERS /SEC FOR DT100 = -INF TO +INF IN FREOUENCY DATA USED -- hD10.wS10.DT100 SECTOR 15 w!NO DIRECTION NOT AFFECTED DI'RECTION O.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 6.0 7.0 8.0 9.0 SECTOR TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TOTAL USAR O.4 0.9 1.4 1.9 2.4 2.9 3.4 3.9 4.4 4.9 5.9 6.9 7.9 8.9 INF MNE 0, l. it. 14. 8. 4 O. I. O. O. O. O. O. O. I. 40. 2.0 NE O. t. 5. 7. 4. 2. 3. O. O. O. O. t. O. O. O. 23. 2.1 ENE O. 2. 6. 6. 42, 2. 2. 2. O. 1 O. O. O. O. O. 33. 2.0 E O. 3. 13. 16. 6. 18. II. 5. 2. O. O. 1. O. O. O. 75, 2.3 ESE O. 6. 25. 30. 28. 10. 19. ft. 13, 5. 5. 1. O. O. O. 153. 2.5 SE 0. 3. 22. 23. 32, 37. 34 28. 13. 11 15. 13. 2. O. O. 233. 3.1 SSE O. 6. 9. 4. 15. 20. 44. 36. 45. 40. 55. 29. 8. 1 O. 312. 4.2 5 O. 7. 6. 9. 10. 16. 33. 36. 34. 34. 55. 17. 8. D. O. 265. 4.1 55m O. 7. 4. 11, 10. 19. 13. 20. 26. 13. 22. 12. 3. O. O. 160. 3.7 SW O. 8. 10. 4. 7 12. 9. 7. 6. 7. 3. 5. O. O. O. 78. 2.9 wSW O. 6. 11. 8. 6. 7. 4. O. 3. 1. O. O. O. O. O. 46. 2.0 W O. 25. 21 6. 3. 5. 2. 1. O. O. O. 1. O. O. O. 64. 1.4 wNW O. 33. 68. 20. 10. 10. 2. O. 1 G. 2. O. O. O. O. 146. 1.4 Nw 0. 47. 73. 50. 33. 12. 10. 7. 5. l. O. O. O. O. O. 208. l.7 NNw O. 7. 30. 46. 43. 50, 39. 12. 8. 11. 1 O. 1. O. O.

248, 2.4 N

O. 4 14 22. 14 17. 6 O. 1. O. O. 2. 1 O. 2. 83. 2.4 TOTAL O. 136. 328. 276. 241. 241. 231. 166. 157. 124. 158. 82. 23. 1. 3. 2167. 2.9 NUMBER OF INVALID 085ERVATION5z 41. PERCENT OF VALID 085ERVATION5a 98.1 VI-10

3 "2 %J G 0 0 0 0 0 0 0 0 0 0 0 0 9. @. c.>.@. 4m 3 O@COOOOOOOOONNo@T J OcOOOOOOOOOO@TO@M c.o. c.o.o.o. o o o.o.o.o.o.o.o.O.N. 4> O COQOCC,u003C00000 C000000L000000000 OCE o c o.c.o.o.c.o.s. 7 0 0.o.0 0 0 o. >Z ~ C0000000000000000 00000000000000000 g 0 0 0 0 0. o. 0 0 0 0 0 0 0 0 0 0 0 00@ O e 0 00000000000000000 E O O 00000000000000000 U = 00000000000000000 C. >0 @ w > o o N = b N 03000000000000000 m E O O@c000000000000@T w - C O P. 0000000000000000.. M w 3-00000000000000000 2 Z Q COOOOOOOOOOOOOOOO

O CO@* C000000000000000o O E +++ @' N d 00000000000o00000 ww I t H 00000000000000000 O

c. o m.

00000000000000000 x o w rm W Z e T T 00000000000000000 3 Z l 'h i = M m B o 00000000000000000 0 \\ f a 4 = %J O. C T. 00000000000000000 m e < U M > o W T T 0000000000000000Q w a = Z = G O O COOOOOPOOoCOOOOOO e c 00000C.00000000000 60@ w = U w M n OOQrJOQF ' O O O O C n 'h w w L a U 6so,Cm=*"!LwwoOOOO 4 = w .. 0000000000000 C. O V. Q w 10 w > w 3 O Z 4 m e Q0000000000000000 o Z w 3 = U k w 3 2 O 00000000000009009 w Z 40@ 0000000000Qo0000o N N. Z Z 4 => a +

  • *+++

3 o Z N N 00000000000000000 0 3 m Z O m m h P C00000000000@o00@ C. 0 9

o. o. o.o. o. o. o. o.o. o.o. o. o. o. o. o. o.

n e c w U e a 3 m g w 2 = 2 N N CCCOOcoCoccooOOOO Z A I = o Z O O Q w o m = 0 00000000007.J00000 > =

4. >0 @
c. o. c. o c. o. c. o. c. o.t'. c. o c. c o. o.

4 s O > 0 g p Z 000000000SC000000 2 Q > 0

a 3 w z U a Z Z N A w 0 W e M 00000000000000000 S A 3 3 a COT 00000000?O000000o o e o O / O 8 = * - * -* -

  • C000000C0Co000000 0 3

>C w T I U= m O O = 0 > => m o > J = U 00000000000000000 < J 24 N >> > > w co@ 00000000000000000 > < Z Z Q A => * = * * *- ~~ u m o C 00000000000000000 ~ QE O s = E o 4 7 a sw 00000000000000000 o O. C T. 0 0 0 0 0 0. o. 0 0 0 0 0 0 0 0 0 0 O w. g Z gy N Q9 O o 00000000000000000 w w 2 O U o e 4 3 3 O U2 3 w Z 4 f" % f O== \\ ~ J u ( a e o J s' o w pJ - a.. < U w w w w a n i e > U w Zw2 ewe ABA 232 O W 4 4 0 ZZwWWOMHMAEBEZZZW J > tw D 4 46 4 Q O m

J / i) ./ 3 @ N.T.m. o. m. T.=.Q.O. C.@. N. N. N.N. 4c 3 N--NOCNMooONNNMNM J T@@MOOTTOCOSTm@@- 4 - o.o. o. o. O.O.o.o.o. o. o. .N. @. O.N. O C0000000C0000000-C0000000000000000 C. O L 00000000000000000 pg O = C0000000000000000 00000000000000000

c. ro m. o.0000000000000000 zO m a C0000000000000000 4

Oo U C000009000000000T w > Com C0000000000000000 A O N' ;= N* 0C000000000000000

* * * * -

  • e M

E O 00000@C000000000@ w -

c. o m.

o.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.o. W w 3 w C0000000000000000 3 = Z O 00000000000000000 = - O C. o m. 00000000000000000 0 3 r W C000000000000000o w e 4 1 M 0000000000000@mO4 0 @Om o000000000000000-X O w =>

  • j'<w w

Z e v v C0000000000000000* \\ s = 3 Z N = R O m \\ 2 4 = C0000000000000@O@ g O. C T. 0000000000000000.o. s + > > w e 4 U r 3 M > Q w T T 00000000000000000 W 3 = Z = a o O 00000000000% 00000 @ O m. 0 0 0 0 0 0 0 0 0 0 0.C. 7 0 0 0 0 w = m c U w M (5 00000000000000000 W W a a U e = w C00900090000@OM0@ O. O T. Q Q Q Q Q o. c.o.c.o.o.o.o.o.N.O.M. Q w g M O Z < M M C0000000000000000 O Z w 3 = u > w I z O 200@O00000003TT@m w Z 40$ C000000000000--o@ o e Z Z 4 3 o Z N N 0000000000000S0C0 2 = Z O > = = h 3 @O00000C0000Co4O@ O. >O T. C.0 0 0 0 0 0 0 0 0 0 0 0 0..0. u a m. U e s o = w 2 2 N N 00000000000000000 Z A 0 2 w > a = O H Q = 0 0 O@@C000000000mO0m > = M = O > 0 @Om o000000000000000-3 2 4 C0000000000000000 2 O N

=

3 w 2 U C 2 M w o w t M C0000000000000000 C e COT C000000000000000o o 2 3 3 = O O Z o a C0000000000000000 0 2 90 w Um 3 O o = 0 > => w O > J = U C0000000000000000 4 J 24 N >> > > w 40m C0000000000000000 > < Z S WH Z O M 0 0 00000000000000000 m = = = OE O s = 4 7 E O 2w C0000000000000000 O -o ws 009 00000000000000000 G Z RU h 03 C O C0000000000000000 w w o 4Z m W e 3 m O UZ 3 w e f O = Z {%\\ = J 2 m a e O J w pJ N 4 at U W W W W B E D B > U w ZwZ AWM AEM ZBZ O W 4 4 A ZZWWWMMOHeBBEZZZe J Z> e 4 44 4 Q o E

) \\,;' s G W O.m.n.@. 2. W.a N.@.O.v. v.@.m.k N. O 3

  • N=NNO@@nnONNNNNn J

@TnnONnND@C@T@h=O .~.N.N.o. n.N.n.o..c.o. . @.m.c.N 4> O C0o000o0000000009 00000000000000000 006 00000000000000000 pz = 00000000000000000 00000000000000000 00@ 00000000000000000 g O e e C000000o000000000 E Oo U COOOODT@COOOOOOTN S o m. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.N. Jm y u b C00000o0000000000 H 2 O C0000300000000000 W C. o m. C. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 M w 3 2 W 00000000000000000 Z O 000006@@O00000@Om

O O C. w @. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.N. Q 3 W 0000000000o000000 W t 4 6 A 000003@c000000@or. O @O@ X O W =>

  • 0000000000000000N W

Z M T T 00000000000000000 !m' = s e n a g M R O t a 4 = 0000000900000@@Cn 1 \\. O. wC T.

o. c. o. o. o. o. o. o. o. o. o. o. O. C. O. O. N.

= e < y y A > 0 W T T C0000000000000000 W 2 = Z = 3 o O OOOOOOO@4mOOO@eQN W = com 000000000-000000T H Q U W n n C0000000000000000 W W a 2 U 4 = W OOOOTOOWOOOOOSTON 0 t 0 0 T. 0 0 0 0 0 0 0 0 0 0 0 0 0 0.. 0.n. g a p Z 4 n n C00o0000000o0o00o C e W 3 A V k E a O COTTOCOCQOOOc@nen N W Z @ O S. c.o.o..o.o.o.o. v.o.O.O.Q.o.N.N. m. o z g g 3 2 N N 00000000000000000 T w 3 = m' O > = = N 3 T@@TOOccoco@ove@m 2 e W O. >O T. 0000000000000..=.o.4 p = w A u = 3 = 3 N N 000000000000Q0000 Z ^ I = 0 Z O A O = 0 n - O m O @ sh @ O O O O O O O @ m T @ ~ > = O > 0 @O@ 0 0 0 0 0 0 0 0 0 0 0 0 0 0..o. 4 4 p g O 00000000000000000 2

-

B W a U X Z = 0 W v W l e @@@c00000000000@o m A 3 3 = OCT C000000000000000N Q Q O Z O E

  • * * * * * * - * * * * * * - *
  • O O

m WO W e C0000000000000000 Z u= 2 O O 0 = > => s o > J = 24 U C0000000000000000 4 J @ O m. 00000000000000000 4 N W e He z Q e 2 = = 0 0 00000Q00000000000 = 02 O w ~ 4 7 6 O EW C0000000000000000 U O WJ O. C T. 00000000000000000 3v g g N 03 O O C0000000000000000 W W O LZ O V U 3 2 8 U2 3 W t = Z L R = J t \\

a o O

J (v/ W p.4 a 4 sh 4 W W W W W E B B B > V W ZWZ MWA ABA ZBZ O W 4 4 W 22WWWHAMMABBAZ2E> J C 4 43 4 Q O s

,~ h s ? I s P .,hk i \\ \\ f .Q/ l [ E W O.M.T. N.e.e.@ o.N.- *. M N @ t. - y s e. -NNNMMTTTMN, NN-M J-M@ COO @mced@TTMe@@ @ @ @ N.T.e.o.T.N.N.T.. N.a @ e.d. -1 s >O QQo*NNOOM-COONc=4 M I - 006 o.o.o. o.o. o.o. o. o. o. o. o.o.o. o. o. u. ocoOococoococcoon >3 w -Q0000000000000000 0C000090000o00009 C. o m. Q 0 0 0 0 0 0 0 0 0 0.o. o.0 0 0 0 g O e e C0000000000000000 O L' O i COOoovee@OOOOOOOT F

U W

H,

c. o m. '
o. c.o. c. c. o.N. N.o. o. o. o. o. o. o. o.h.

o. a N N 000o0000000000000 e i E O COOcQMM@NOOOOOOOm W > e OOm* ococoNecMooooooom e I W .3 @' M@ C0000o000000C0C0-3 Z O 1 OccowhTemoccTCCOW

C. o m. O. o.o.o..M.M M.e.c.o.c. o m o. o.m. Q O 3 p 4 W c c OQQOQQe-QQOC10COM W t a l e Oc@oMMcTTMcQOOmoc Q ' W o m. o.c.o.o. N.N.@.N.a N.o.o.o.o.N.o.c. x Q W W 2 m 9 9 0000000000000Q00N \\ e w. 3 2 T 3 O M = g a < = coo @NNemNtoccTMON I

o. O T.

o.o.o.o. M.M.c.W. M.. o.o. o..N.o.m. m. p-a 4 y e > Q W T T OMcQQCQQQQOOOOOON W E m 2 m a o o coccehamhTOCOT=O- @ O m. o.c.o.o. N.M.@.@. M.a C.o.o..T.o.o. W w e c U W M M 0000000000000000M W W a 3 48 4 = WJ Omme@@@@NemOce-m-C. O T. o.c.o.. c.T.T.@.T. . D.o.o.N.a o.@. Q 6 > a 3 0 Z < M M 000000000o000o-04 Q Z W E = u > w 3 E O mcQNMeme@MmT@e@h-W 2

c. o m.

C.o.o.M.N.N.o.N.T.N.o.c. o. .N. M.C. c. g 3 a 3 .C Z N N 000000C0000000~O4 T E ~ Z Q M > = = N 3 MmMcM-T@eemcec@NM C. O T. H.o.N.o.N. o..o.N. N.o.o..c.o.v. e. T. n e e u e n p = W E ~ E N N 0C00C0C0000000-o4 2 e 0 m o Z h 0 o M O = O Neo-MemmWovceNNec > a m a N O > 0 @ O m. M-

  • T N o o o - o.
  • o N M m @ a 4

f 2 o m C000o000000000C0T c > U . E W C Z Q M W W e W e4mTTOccccccTNeNc e e 7 C. O T. .".C...o.o.o.o.o.o.o. .M.N.M. e. o 3 m o J o g O g 000o000000000000-O E bo W E * - I-Va a G Q = 3 > => a o > J = i E4 - u C000000000000m#30 4 4 N W com oooooooooo.oCocoo-

  • * * * * *
  • Z >

h e MW Z Q e = = Q Q C000C0CQo00000000 m L = QE O L 7 E o - EW C0000000000000000 O C O T. 00000000000000000 o WJ E Z i u N 3 o O C0000000000030C00 W W o 2 U O E O UE W i C t O = 2 4 i / m J g l l E 3 o J s e W DJ a at U W W W 3 3 3 3

  • V W

ZWZ = Ne eBe 232 O W < < M EZWWWO1HeeB332ZZW J > ZH e < g

  • Q Q

E e I h -., _, - - - ~ - _,, -,., - -. n

4 w. 4 \\f): 1 E -] @ = = M. T .O.O N.T.@.@.T.@.@ =. W, 4 . e. i e 3 -NNNNMTTMMN-==-NN J @MN=-NNocce=OM@NN 4 @ N.T.M. @.N.C.@.o. N.W. =.o.O.N.O.W. O QQQ=NphTN=0*McM== T I COOoOOOoCoCoOOOOo

c. o m
o. o.o. o. o. o. o.o.o. o. o. o. o. o. o. o.c.

pg' = Co0000000C0000000 C0000000000000000 00@ C.3000000000000000 g O e e C00000000C000o000 4 OO OOCOOOJOTOOOOOOOT 4,- - U =

o. o @
o. o. o. o. o. o.o. o. o. o.o. o.o. o. o. o. o.

w > O. o r. N N 00000000000000000 %m E O C O O O @ M - M m e. O O O O O O M a w - C. o m. C.o.c.o.C.N.@.N.N..c.Q.O.Q.c.o.t. M3 w p 00000000C0000000= S 2 O COCO @Mp@MTOO@OOO-

O C. >O S. C.O.o.o.o.N.a c.N.=. c. o.c.c. o.o. m. o 3 w 010CocarOOOOOOCON w I a 1 W COOcce=@T@TOCOCO* O @ O m. o.c.o.c.o...M. a o.o. o.o.o. o.o.m. x c w .p w 2 T T 000000-000000000N 3 g. D e = i = g C M \\ g ( = OOOTMe@@NTToco@@@ 4 O. O T. C. o.c. o.N.N.M.@.M...C.o.c.o.O.N. m q y p e > Q w T T C00000-000000000M W a = 3 = E O Q COTMMMN-ToO@cm@cT @ O m. C.o. o.N. N.e. @. c.a. c.c. o. c. o. o. O.=. w = c .p W w M M C000000Q00000000M w w v. 4 E u 4 = w CT@me@@@@T@@@TNe= O. O T. Q o.o.N.N.o.=.@. c.a c.c.o.O. M. Q w > w p 1 3 0 2 4 M M C0000-~C000000009 O 2 w E = J m 3 E O T@@ net @ Neem @MT@cc W 2 40@ o.c.o.M.=.N.c.M.N. .N. o.N. .@.o. g g a p. i 3 0 2 N N C00000000000000J9 2 = Z O 4 a = s 3 @OTT@@NMTOT@MTocT e a u O. O. T. C.o.a - @ @ v.N.a o.a o.N.N.@..4 m e a i = . w E = m N N CC0C0000000000009 Z M 0 Z e = O e Q = 0 m = 0 M @ O e O @ @ e N ue@ @ N N @ e N > = s Q > 0 @O@ N.C.O.N.@.@.o..M.c.C. o.M. @.o.N.@. p g q o T. CC00000000000==O@ 2 = = - u B w M Z O M w w M M@@eNNeT@MTNNeMM@ e M ^ Q Q T. N.o.o.N.M.M. ..O.N T. @.o. e.N.N. o S 3 = Q o g o g .p O COCQQOQQOQQQ*NCON g Ho w a = = I um a O O = Q '1 > => w o > J = E4 - U OO@TMOST@@@e@NSON 4 J M >> > > w @OS C Q Q a N.o o.=*O.O. o N.c M N O.N. e HM Z Q W =

  • Z

= = 0 0 0000000000000000N = = OR O E 7 E O = EW C00000000000o0000 O C. O T. 00000000000000000 O J E Z u N 3 O O C0000000000000000 w w O 42 u W E O uZ w t O = Z a = J E S u O J w ~ 4 ( u W W W W 3 3 3 3 > u w ZWE MWW eBe 232 O W 4 4 W 2EwWWWWAdm3332ZZW J > KH S 4 45 4 Q o w

'l .d5xp ^$.i a- @ @ @ @ @ M. W. Q. 4.=.N. Q. Q. N. @. @. @. 4- .e 3 OC***NNMMN*aa*=C= 6 J D@e4@Ne@OMam@eNTm p Q Q a

  • N.@.N.N.e.m.@.M. T.T.M.=. N.

4> O COOOas===CO=Nacot a C0000000000000000 I 004 0 0 0 0 0 0 0 0 0 0 0 0.o.0 0 0. o. L >2 = 000000o0000000000 L k 00000000000000000 C. O S. 0000000.0000000000 g O e W C000000000000000Q w O-o u* C0000000000000000 t O. O @ 0000000000000000.o. W 1 c + N N 00000000000000000 M 4 E O 0000000009000J00T W = C. >O S. C. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. o. M W 3 C0000000000C00000 S Z O OCOCCCCo@ococcoo@ = ~ O O. O @ 00000000000000000 l O 3 00000000000C.00000 W W e 4 1 i e COOOOOOWN@OOOOTO@ ) O @C@

o. o. o. o.o.o. o.o. m. o.o. o. o.o. o. o. g x

o W /' W 2 M' - T T C000000C000000000 t f a 3 2 ~ 3 0 E 4 = CC0000Ce=Q000000@ l O. C T. 00.00000.*.@.o.000000.@. w e 4 y W > Q W v T CC00000000000000o W m n 2 m a O Q OOOOO@m-NCOOOOOOO f W = @O@ C00000. 9M00000000 r L H Q U W M M C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 73

  • W W

a E u 4 = W C00000>T@@C00@c0@ t C. >0 4 c.o.C.C.C.O.M..o.o.o.o. o.o. o.o. k. Q w > w E O Z 4 M M C0000000000000000 O E W s + a a u > g w 3 2 O 000M@@e9990000030 e. W Z @O@ o c.o.o.C.@.N.=...o.c.c.o.c.o.w. g 2 Z 4 3 0 2 N N 030000000000C000-9 E ~ Z O = > = = n 3 OO@@eNT9@@CCOOOON Q C T.

o. c. o. O. N. M. a - C. o. r O. Q. Q. C. o. =.

{ u e e O. U e u w w j. a N N QooooooooooooOQo-r a T, z o z o e l O M Q = Q M

0 OCOO@N@@c@ewNgoco e

O > c @Q@

o. c. o. o. T. M. o. c. o. o. =. ~. N.

. o. c. h. 4 3 0 C000000000000000* E O m f g 3 W u a z W + M @O9@aT@@@T@@9NMea e A C. O. T.

o. c. c. o. T. =. o. c. o. *. *. *. M. @. N. O. N.

Q r 3 = O 2 O a C00000000000-QQ09 Q s .'O W 4 = = = g O o = 0 [ I b wk w O > J = u o@@o@@eemmeceN@@@ 4 J f a4 4 @ O m. o.c.o.c o.o... N.N.a h.e. M o. o. N. N W Z O MM 2 Q M f ~ = O O 0000000000000000M = QE O w = 4 9 w 3 = EW C00000000000C0000 Q C. o w o.o.o.o.o o.o.o.o.o.o. o.o.o.o. o.o. l-O J E Z l u t 3 Q o Q0000000000000000 W W O 3 u 6 2 W 8 U2 = 2 4 I t m J g O E C J W .J 4 b 4 4 O W W W W 3 3 3 3 > = U W ZWE MWH ABA 332 O W 4 4 M ZZWWWMA@WH33322ZW 1 J > ZH 6 4 46 4 Q SC ok s i 4 ? m

l l rs \\ } t l v E .O. O. .O.N.T.@.T.@. .M.o.m.O.m.e. <c 3 coo-N---NO-N-O-c-J MOO @NcMMOT@mm@@m-C.O. O. o.T.@.N.N. .N. .. o.C.o. m. 4> O C000000000000000N 4000000000000009e C. O s Q0000000000000000 pZ = 0000000000C000000 00000000000000000 00@ 00000000000000000 g O e m C0000000000000000 6 Oo 00000000000000000 U - O. O @. 00000000000000000 w > e Q p N 5 00000000000000000 e3 O Q0000000000T00009 w - C. >O @ 00000000000000000 H 3 w 00000000000000000 3 Z O C000@C0000000000m = - O Com C0000000000000000 O 3 => + - * - = +

  • * * = * * * * * = =

w 00000000000000000 w i a 1 H C0000000000000000 0 @ O m. C.0000000000000000 K Q y .y f.,N. w z o T T oOOOOooOOoooooooo s o Z ~ i = .i~e} = 3 G I 2 < = 00000004T0000000m O. C T. C. 0 0 0 0.C.0 0 0 0 0 0 0 0 0 0 0 + > > m < y w A > Q w T T C000C000000000000 w a = Z = 2 O O 000000009C0000009 w = @O@ C. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 e Q .p C0000000000000000 U w M M w w 4 R V 4 = w 000000@O00000000@ O. C T. C.0000000000000000 Q w w 3 0 2 4 M M 000000C0000000000 O Z w 2 = U w 3 3 O 00000000000000000 O W Z @ O m. 00000000000000000- = m. 2 Z 4 3 O Z N N 00000000000000000 N Z o 2 = > = = N 3 C000mC0000@c00004 e c w U OOT 0000000000000000-00002000000000'0'00* O N = Z W = Z A 2 = m N N 0 Z > + = = 0 O e Q 0 0000@@O900000000@ a M = O

  • O @Om C000000000000000-S Z

'N C000000C000000000 3 Q =

  • e w

2 3 U Z T d W o w + A COOSM-m@@@T@@T@ON O A 3 3 = 004 Co. con 0-oCo-Cocoo@ O CO O Z O u 4 - * + - - - - * * * * *

  • a C000000000000000-Q q HO w 2

0 U= 2 O O = > => s O J = M4 U @OOOOmo@4@e@Q@C@N 4 J N >> > > w @O@ 0 0 0 0 0 0 0 0 0 0 0 0.. Q. 0 0 4 Z e de Z Q o .p = = Q O C0000000000000000 = - Ca O w 7 6 0 - Ew C00000D0000000000 O C. O T. C.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O WJ g Z s gu N 03 O O 0 0 0 0 0 0 0 0 0 0 C< C 0 0 0 0 0 w w Q 4Z m U c 3 a fm O UZ 3 w f \\ 4 o m3 2 4 i j i = JO g E CZ O J \\s_ / w 3J 4 44 U W W 4 W 3 3 3 3

  • U w

ZWZ AWA ABA ZBZ Q W ( H ZZwWwHWMAA333ZZZW J ZH m < <z < o 30 06 t

~. 's J _ . j-ss/ 5 ' TA8LE 159 - ALL DATA PERIOD 07/01/1987 THHOUGH 09/30/t987 RUN FROM TAPE SERIES TRI-EX OMAHA PueLIC PowtR DISTRICT FORT CALHOUN NUCLEAR STATION JOINT FREQUENCY DISTRIBUTION WINO DIRECTION V5. WINO SPEED IN HETER 5/SEC FOR DT100 = -!NF TO +1NF IN PERCENT DATA USED -- Wolo.W510.0T100 SECTOR 15 WIND DIRECTION NOT /.FFECTEC OIRECTION 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 6.0 7.0 8.0 9.0 SECTOR TO TO TO TO TO TO TO 10 TO TO TO .TO TO TO TO TOTAL USAR 0.4 0.9 1.4 t.9 2.4 2.9 3.4 3.9 4.4 4.9 5.9 6.9 7.9 8.9 INF NNE O.00 0.05 0.51 0.64 0.37 0.18 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 1.85 2.0 NE 0.00 0.05 0.23 0.32 0.18 0.09 0.14 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 1.06 2.1 ENE O.00 0.09 0.28 0.28 0.55 0.U9 0.09 0.09 0.00 0.05 0.00 0.00 0.00 0.00 0.00 1.52 2.0 E 0.00 0.14 0.60 0.74 0.28 0.83 0.51 0.23' O.09 0.00 0.00 0.04 0.00 0.00 0.00 3.46 2.3 ESE O.00 0.28 1.15 1.38 1.29 0.46 0.88 0.51 0.60 0.23 0.23 0.05 0.00 0.00 0.00 7.06 2.5 SE 0.00 0.14 1.01 1.06 1.48 1.71 1,57 1.29 0.60 0.51 0.69 0.60 0.09 0.00 0.00~ 10.75 3.1 SSE 0.00 0.28 0.41 0.18 0.69 0.92 2.03 1.66 2.08 1.85 2.54 1.34 0.37. 0.05 0.00 14.40 4.2 5 0.00 0.32 0.28 0.42 0.46 0.74 1.52 1.66 1.57 1.57 2.54 0.78 0.37 0.00 0.00 12.23 4.1 55w 0.00 0.32 0.18 0.51 0.46 0.88 0.60 0.92 1.20 0.60 1.02 0.55 0.14 0.00 0.00 '7.38 3.7 SW O.00 0.37 0.46 0.19 0.32 0.55 0.42 0.32 0.28 0.32 0.14 0.23 0.00 0.00 0.00 3.60 2.9 wSw 0.00 0.28 0.51 0.37 0.28 0.32 0.18 0.00 0.14 0.04 0.00 0.00 0.00 0.00 0.00 2.12 2.0 - w 0.00 1.15 0.97 0.28 0.14 0.23 0.09 0.05 0.00 0.00 0.00 0.04 0.00 0.00 0.00 2.95 1.4 WNw 0.00 1.52 3.14 0.93 0.46 0.46 0.09 0.00 0.05 0.00 0.09 0.00 0.00 0.00 0.00 6.74

1. 4 -

Nw 0.00 0.79 3.37 2.31 1.52 0.55 0.46 0.32 0.23 0.05 0.00 0.00 0.00,. 0.00 0.00 9.60 1.7 NNw 0.00 0.32 1.39 2.12 8.98 2.31 1.00 0.55 0.37 0.51 0.05 0.00 0.05 0.00 0.00 31.45 2.4 N O.00 0.18 0.65 t.01 0.65 0.78 0.28 0.00 0.05 0.00 0.00 0.09 0.05 0.00 0.09 3.83 '2.4 TOTAL 0.00 6,28 15.14 12.74 18.11 11.10 10.66 7.65 7.26 5.73 7.30 3.77 1.07 0.05 0.84 100.00 2.9 NOMBER OF INVALIO 085ERVATION5m 41. PERCENT OF VALIO OBSERVATION $m 98.1 VI-18

q \\ l 3 C.M.M..c.o... C.N.T.4.N. S. 4c3 -NNMooNNoNNMMt%NM J 4 NNN-oo-a o-40-cTTM c >o P O. o a ooooooooooooooooo. >Z ao l l

o. o @

QQoOOoooooooooooo i g I o O L o o. y C. o m. 00000000000000000 w > A o. N l A I E o w -

c. >o m o000000000000-00*

e M 3 w 3 .Z o. o 3 0 0 0 0 0 0 0 0 0 0 0 C F. 0 0 0 M. o 00@ w c d W t 1 e x o w . r-cooocococcoOQ-NOM o @c@ e g g .Z W /s O Z \\ s M 3 o ) i' / g g / . > > 004 ocococococo-M-oco M < U p M > O w 4 W E Z 3 o o

c. o @.

CocooococcooN-Nom w

== A o O w M M W w a U .z e > w ag

c. o t.

C00-000000-400000 o U w Z L I o w 4 M M o Z 3 2

    • o k

w 3 w o o--QQoooo--ooooMN M c. 2 Z

c. o @.

Z Z w 3 o Z N N N .Z. o 2

==> N 3 C. 0 4 - ~ ~ o c o a- - o o - o - c o - e u .C L U m A u = Z w 3 m. 2 N N Z A o Z N I

== 0.e A o = = = - = M .* O o > o

c. o m C 0'0 0 0 0 0 0 0 c - 0 0 0 0 0 -

2 N e m > c. 3 W 2 U A w I Z N ................. m e e. 0 w t m 004 -cooococococN-oct o in 3 3 o Z o u c o E >o w 2 I O= g o o .o = J o > = =

  • w 0

>v eg g g ag a c o m. o0000000000000000 N W .Z. e eM Z o e >= me me o o - om o w L o N 4 7 - gw o o wJ 009 00000000oo000000o 3V 3 Z o o3 o o w w - &Z e w 4 3 2 o UZ 3 w ,rh t o me 3 Z Jo a g 'g = g i S E CI o J \\ / 4 W 3.J 4 44 V W w W W 3 3 3 3 > U W ZWZ ewA A3e Z3Z o W 4 4 0 2ZWWWAAAAM333ZZZ> J I> c < <a < o o w h

jm \\ \\ n_J E N. 4. W. T. to. N. 3.. e. @. @. @. M. CD. T. N. N. <c 3

    • N-NN@@@MMMNMMMNM J

e........ -....... @ @ - M M @ C D @ * @ @ @ - O.* @c -MM Q ~ C. O E C0000000000000000 >Z ~ O. O @ CCoOOC*-OCCCoOoON g O to e w oO V C. 0 @. C00000M-000000004 W W Q N N O E Q W M Q O C. coCCON4NNaCO*Nood W g 3 .Z. O. O 00@ O 3 COCOON"-@NCOO@ MON N W d W i a I e O 40@ X o w o-COOOOOOQNo-NMoe = , m. W Z e 4 v e

== 3 Z O / s \\

== 3 O. N 'v) t a C. 0 4 00000-ocQMQQM-b00 .= m 4 U d > Q W T T W 3 m Z m 2 O O =................ w n DO@. OQOO*Oc=O~o=NNeon e 0 = U W M M W w t= a E U a. W Q u w 009 oco-caco-oNMMwcM9 Z w N I O W 4 M M O .Z 3 3

  • O >

g 3 w o 3 Z 000 COO-NocQ-NNO-NO-N. N O. Z Z w p-

  • J O

Z N N N 4 =e .Z. .O N 3 CD C. U C04 MNoo-co=v-ooNcMMo n S a W N A a 3 1 N N Z A I

== w W Q 0 2O M o Q > O C >O O. CNo-CCoo-OQQ-QQNN N .Z = N.

==

  • g U

3 w z Z A W G W 6 H. O O 3 3 009 a o - c o o C *- ~ ~ o N o - a - o o e = O Z O e

== Q E >c w a== ~ O I U= m o o

== 0 > = = > w o * .J g< - y .. < a N >> > > w c O O. -00000000000-O--9 m WH Z Q W .Z. = = 0 Q ~ QS O w 7 Q gW = Q O W.J C. O 9 C000000000000 > 3V 2 Z Q O3 o Q w w - aZ m u O 2. 2 O UZ 3 w /"Nh I O w3 Z a =* JO a \\ ) E DI O J c w pa s%j - a u( U W W W W E 3 3 B U W ZWZ OW4 ADH ZBZ O W M ZZwWWOAMAM33322Z> .J Z> e < a 4 Q O w

a i#

R Ef

\\% 1 g @ @ N.N.@.M.O.@.@. e.h.T. .N. M.@.@. 4m 3. N.= N - N @ @ T @ M N N T M M N M .J ............. e,.. M.= T = @

  • e @ N @ e ti @ c N N N @

4>

  • MN m

O O. O E OooOOOC-OOOoOooO- >2 m ** o O m. - Oooo0-o-OooooooCN E ew O e e E CQ-y ' C. O S. _COOOOONCNQQQQOOCT W M Q M M M E J W M 00@ COQQOMTOMoccMCOCM 3 W 3 .Z. C. O 000 CQQOOCTM--COM@*QS Q 3 W W I a t M - O.

c. o m.

-CocoCN--c-oo3NNON V Q W u 2 M T T \\ .t 3 O a. 3 Z M N = 2 g. C. 0 4 OCOOO*NO--OCTT@-@ w W < u M > Q W T T W E me Z g O o @O@ -COOCCCCONO-QM@CN W

== M Q J W M M W 46 U .E. a W q Q u m 004 T O C O Q Q.= N N N N Q o @ @ - @ Z w r= N 3 0 W M M O 2 30 > 2 = m 3 W O E 2 @O@ C-@N=o-MO*C==N@N@. T. Z Z s N e 0.= Z N N e 3 .Z. o. E N 3 .e. u 004 coNCO-O-CO-N-M-Nm a e . W =>

  • M a

m E 2 N N Z M 0 2 > e== == 0 M O m = 0 ................ * *== O > O @O@ M-N-co-CocoONaco- < >= N 2 =

==.= - E 3 W 2 u I Z ~ M u.: 0 W t M ................. c M 3 3

== 004 C==CCOQOooo--ONo@ O e O 2 O a O C E >o W 5 I y== E O Q .= Q P. = = > w Q > .J

== 2( = u g .J N P- > > > W @O@ Q-ONOCQQOOQQQ-C*W Z e MM Z O M Q O

== S *=

== QE O w 6 O 4 7 EW ................. Q C. O T. 00000000000009004 Q WJ E 2 v O 3 C Q W W 2 e u = V 3 E O UE 3 W 4 0== Z a

== J E E O J @ 'W 3J

  • 4 ik 4 U

W W W W 3 3 3 3 > U W ZWZ MWM M3M Z32 O W 4 4 W ZZWWWMMMMM33322Z> J Zn S 4 5 4 Q Q w

s i f N M c.N N.T. @.@.N.T.o.@.@.@..N. .N. <o 3 ---NMM4T44 NNMNNM .J .. e.............. @o@coNNcq-@@oMNTT NM-N4NoNMN-NNMNO@ r. co o> O. o 6 oooooooooNOoooooN >Z coo-coom-coocooCD C. o @. Go o w oo V - W C0@ ocoo--ooNocco*com N e Q =>. N N e E o w - > e 00@ o c o o v m @.-:D - - o N T - o o 4 3 w C 3 .Z o. O c o m. occoNd@-@NoccM9CT -N-N o 3 r w c 4 w I a i e o c o m. occoMaoNN--ooongom S /m'\\ X o w => M T T N .Z. W t t 3 Z N 3 / .t. 3 o w 3 %./ a . > > 004 c o - o M N - 4 N N c N T M.= N - @ y e T M U 4 > c w T T W 3 Z = 3 o o c o o - N 4 M lc M M o M 4 - *= N - O. o @. w N-cp A c U w M M w w e U 1 2 > w c U u. 009 o c o.- o N @ v N N N N 9 9 @ ~ @ -Na-@ Z 6 3 o w M M o .Z 3 2

  • o >

....... e........ s 3 w o (D ONNM@@NT-4N@o--@@ a Z r,1. o @ --- co g Z Z m o 3 o Z N N 9 .Z. o. E => N 3 U Q o T. T 5 N @ co o M M N N N M @ g N 03 it e. T. to e as w c Z A E 3 N N Z o. 1

==o o. .e. o n o P= 0 @o@ a3 0 m - @ N M 4 m.- 9 9 9 N N *- @ - -== a3 > < N Z 2 3 e w = - - w 2 U I Z o

D M

A* 4 - @ 9 M N - @ - o ao o 9 N o lo d w i O. o 9 3 3 N o o Z o u o. (E Wo w 3 e o. E o O J I U. > o ,J w v g(

c. o. @.

@c-Moo-o-oMNeoN@N@ N >> > > w .Z N N cc ed .Z o A p a o o w CE o A o 7 ................. o - ga ocooococcoccoNocN C. 0 9 o wJ m Z 3U w w o O3 o O G3 U

  • 4Z 3

2 [ 's o 3 w s o U2 2 4 e 0 4 o m3 = ao z a r \\ / i v e a eI o 4 w 3.J 4 44 W w w w w 1 3 3 3 e U w ZwZ ewA A3e Z32 o W (. W ZZwWWWWAMA3332ZZ> .J I> c 4 4K < o 30 e 04

/- / \\ l 4 s / N,/ i I 4 E @ C0..@.o.@.M. T. c. @.N N.N @ @ o.o. <a 3 oC--NNNMMN*N*e.~=N J o N 4 4 N N N 4 a o N o - @ @ cc M T@TNM-Nc=@Na@ o O m

o. O w ooOoooooo-ooooooa wZ

== coooooooooooooooo. O. C @. 3 O to CD w o o. u C. o @ ocococooNoooooooN W W Q P= b. M 2 o W 0o000004~~ ococco@ 00@. 3 W 2 .Z o. O co@ occoo-cmc--cooMot Q R W W W I a e e 0000004-Coo"D-oob O D. o @. a= X O W (N W Z e T T M 3 Z / e = i N 3 .o l ! . > > 004 ococo@~~Mo-ca-Noo. g 2 4 gw H U N y O > Q W T T i W z,,e .m Z 2 o C

c. o @

c o o c o r= @ N - o

  • 0 M a N O P=

W = N A Q U W M M l W W l a U 4 W c U m 004 ocoo@MMNN-ooNNoo. Z m P = T 2 o W M M o Z 30 > 2

== m 3 W o m Z 4 o O. o o o o e 4 cc - M o M @ N cc - - P-o 9 a 2 2 s 3 o Z N N 2

== Z Q N e. e.e e= M CD C U ooT o o o a o e o T o o - M P= 0 N

  • P-

== W -N A n E 2 N N Z A Q Z P. +== O m.= Q = e o M O > c

c. o O oco-NN@MNaNMTN-C@

a NN P= N Z a > a T

= *

U = 3 W 2 I Z o M W g A Q W g A T - M N e Q P= N N o t T T e o b @ o e

o. c t 3

3 ~ N-- o o o Z O II Q 3 >c W 2

== Q I U== E o o J

== o ( g > = = > w >y g(

c. o @

@ - - o - N P N c 4 m os e N e @ ~ > < P= W .Z.e > -NN N .Z. o W e ed O o

==og o w w o 7 e ................ O ig W = C. O T. ococoo-ococom-oc4 o WJ 2 2 3U o O3 o C w W 4Z U = 2 a W Q UZ 3 W /N 4 0== 3 Z 4 \\ Jo C m \\ 1 e a eZ o a \\"/ o W 3J = a a< U W W W W 3 E E B > U W ZWZ ewe MBA ZBZ o W M ZZWWWOMMMOE33ZZZW a > I> c < <3 4 o o w

m. _.

<:D. 'I - \\% E 'N.N.T.@. >.N.N.=.T.4.N.e.@.=.@. e.@. 4. g 3 COOO==ONMNQQQN=C* 'J .................g @ @f4 N e @ M 4 - M M

  • N = e N N e.= N
  • TN N

Na = O N O. O E OOOOOCCCOOOOOOOOO >Z O. O @ OOOOOOOOOOOOOOOOO g > + 0 e e E O O' .U 'e W k 003 OCOCOQQQNCOQQOOON e Q h N e E O W C. o m. OOOOOOOONaOQQaCog e H3 .E. ' O' 00@ COOQQOON=NCOOM=O@ O ~ O 3 W d 4 W i a e e Q CO@ OCQQQQOOMMOCC= CON W O w W 2 e T T a

    • 3 Z W

a N

== 3-0 [ g-g O. O T. CCOOOOON=MCOOOOO@ F W d u H > Q w T T W .s Z a C Q w

== @C@ OQoOOOONOOO=oNoom e Q

  • P-U w M M W

W U E 4 > W q O. >C T OOOO= COON *COOO-Oe Q U w 2 w g gw 4 M M 8> = = 3 w Q m 2 00@ COOON=O*C=COQOCOO O z 2 w 3 0 2 N .N O = .Z. O. E

== k N 3 e e O. V C. O T. QCQOcNCOCOCOTMOOT e = A a w

== E T a N N 2 e O Z > + ** 0 .M. Q

== a O M N O > 0 00@ aQQQTMoaQ*o=4T=-e N 4 2 N

  • = =

m > 3 w 2 U A w T 2

  • Q W

, e ................. g a C O T. QQQONc=Q==Na@cQ*N O e 3 3 M O O 2 O e a >0 w a a = Q 0 Z U== E O O

== > = = >. O > J

== U J g( = A >> > > w 40@ QMONNN@@@C4=@@@Me 4

a. M E Q M
  • N Z

M e

== Q O

  • =

QG O L = 4 0 4 7 gW ................. O o WJ QOT NC=COOaQQ*NNNMO*@ 3 2 BU . p= O O3 O O w W O L3 = a E O UE w 2 & I O ** -o J q M e Q J 4 W 3 = f. &4 U W W W W 3 3 3 3 > U w 2Wz AWA m3e 332 O W 4 4 4 22WWWedHWW333E22> .J Z> e 4 5 4 O O b -s

j.. ( ) f E @ C.N.N #. @.N.T. M.@.@.@.@.~.T.c.3 <m 3 -OOO*OO-N-CONNo@a .J No-MSNG4CMTTN@NGS N O> OOw QQOC-OOOOOCO-CCT@ >Z = 00@ bbbbbbbbbbbbbbbbb 2 O e e w O O v - 00@ 00000000000000000 w > O. A N N A E O w 00000000000000000 > e CO@. 3 w 3 .Z Q O 003 QCocOOO-NCCOONOO4 O 3

  • =

w 4 e w e a e e K Q w

  • > =

0000000000000 O 40@ w Z A T T Ln 3 Z rN e = N / = 3 O 'f a < = s Q C T. 00000000-0C00000-w 3 3 v e < v M > Q w T 4 W 3 = Z = o.= o g 003 000000000C0000000 w M Q U w M M W W a 2 U ( = y w C. O T. 000000000-00-000N 0 v wZ w 3 0 w M M C Z 3 2

== 0 W w 3 w O -.......+ + 3 Z C. >O @ COCO *OCOOOCOOCOO-N k. Z Z w 3 0 Z N N M .Z .O E = 8 3 p O. C T. =o00000000000000-u a u .e as A a .Z Z O w z

  • 2 N

N O Z .O. .A. C o M N Q > 0 c o m. C0000M00-0C000004 4 N .Z. a > U - 3 W 2 + w Z T, a w a ................. m e COC-CONOOCCO--OQ4 O e 0 >0 4 3 3

== O O Z O a O g 50 W z um a o O = Q J = > = = > w Q > y .J g( h >> > > w co@ -O-NANowTNTTT4NTO ID MW Z Q A o Z

== = 0 0 = QE O la m O N 7 ................. o - gw o w.J COT ocoo-NoooooooOOOM 3V e> 2 Z Q O3 O Q w w L2 m u

== E a O v2 3 w i =3 Z a n' O. .J O g f C,Z O J [ E a s c wa E< v w w w w a i i n > v w < < ZZ WWO Ad E33 22 w - Ze C <M < Q O w

s d TACLE 158 - ALL DATA PERIOD 10/01/1987 THROUGH 12/31/1987 RUN FROM TAPt SERIES TRI-Ex Oe8AHA PUBLIC POWER DISTRICT FORT CALHOUN NUCLEAR STATION JOINT FREQUENCY DISTRIBUTION WIND DIRECTION VS.- WIND SPEED IN METERS /SEC FOR DT100 = -INF 10 + 1 NF IN FREQUENCY OATA USED -- WOIO..wSIO.D7100 SECTOR 15 WIND DIRECTION NOT AFFECTED OIRECTION O.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 6.0 7.0 8.0 9.0 SECTOR TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO. TOTAL, USAR O.4 0.9 1.4 1.9 2.4 2.9 3.4 3.9 4.4 4.9 5.9 6.9 7.9 8.9 INF NME 2. 17. 11. 12. 14 O. 4. 1. O. O. O. O. O. O. O. 61. 1.5 - NE O. 10. 83. 8. 10. 4 O. O. O. 3. O. O. O. O. O. 46. l.6 ENE 1, 3. ft. 5. 5. 9. O. O. 3. O. O. O. O. O. O. 35. 1.8 E O. 9. 7. 4. 7. 6. 3, 1 O. O. O. O. O. 1. O. 38. 1.9 3. 2. 4. 1 O. 1. 116. 2.4 ESE I. 8. 16. 22. 24 16. 12. 3. 3. . 10. -18. 14. 1. 1. O. ~ 373. 3.2 SE 2. St. 20. 10. 21. 24. 21. 11. 9. SSE 7. 19, 11. 10. 4. 86. 10. 18. 14. 12. 31, 28. 15. 1 O. 191. 4.0 O. 13. 6. 9. 10. 9. 8. 13. 9. 9. 21. 17 11 5. 1. 143. 4.1 55w 0. 16. 6. 7. 6. 5. 9. 4 8. 9. 21, 16. 8. t. O. 116. 3.9 Sw 1. 17. 3. 3. 3. 9. 7. 6. 9. 5. 8. 4 O. O. 3. 78. 3.2 wSw 2. 21. it. 7. 5. 8. 7. 1. 1. 2. 1. 1. O. O. O. 67. 1.8 w 2. 35. 9. 8. 8. 16. 19. ft. 8. .1. O. O. O, O. O. It7. 2.1 WNw 5. 63. 41. 35. 34 19. 20. 11. 15. 14. 11. 6. O. O. 1 275. 2.2-Nw 11. 40. 34 39. 46. 23. 36, 30. 20. 26. 30. 8. 1. O. O. 344 2.7 NMW O. 45. 23. 19. 17. 22. 29. 31. al. ft. 13. 1; O. O. O. 222. 2.5 N 1. 25. 13. 14 19, 13. 15. 2. 2. O. O. O. O. O. '4 108. 2.2 TOTAL 30. 354. 235. 2t2. 233. 199. 200. 143. 110. 103. 156. 99. 37. 9. 10. 2130. 2.8 NUMBER OF INVALID 085ERVATION5m 78. PERCENT OF WALID 085ERVATION5s 96.5 VI-26

y-

  • )

w/ E W M.M. .O.O. ..O.N.T.4.N.m.*.@.@. 4m Q -NNMQQNNONNMMTTNM J @@@@Occco@@MNo@@@ ( C. o.c.o. c.o. o.c.o.o..N.@.N.a - T. O C00C000000C00000N 00000000000000000

o. O w C.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 mz

= C0000000000000000 00000000000000000 00@ 0.Q.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 g O 00000000000000000 w oO u e C0000000000000000 C. O @ 0 0 0 0 0 0 0 0 0 0 0 0 0 0.0 0 0 w > M Q N N 00000000000000000-e 3 o 00000000000009009 w - > e 00@ 00000000000000000 w 3 000C0000000000000 3 = Z C CC00000000009h00-

C. O @ C.0 0 0 0 0 0 0 0 0 0 0..9 0 0.@. O O 3 W C0000000000000000 w I a e e OOOOOOOOOCCOOT@CM O C. O @ 000000000000000.o.. x 0 w A T 4 00000000000000000 .Z W /N e 3 Z P% \\ = 3 o N i (y} 0000000000049000M s 2 4 = C. 0 9 C.0 0 0 0 0 0 0 0 0 0 0..o.0 0.N. A 4 y p e > Q w T 4 C0000000000000000 W G = Z = 3 O C 000000000000@@O04

0. >0 @
c. o.c. c. o. o.o.c.c.o.o.o.c.o.. O.N.

w = m e c V w M M C0C0000000000000C w w e A 3 U = w 000@c000009@c000m C. >0 4 C.o.c. o. o.o. c.o.c.o.o..c.o. c. o.N. Q w > w 3 O Z M M C00000000o0000000 O Z w a = U > w 3 3 O Ov4COOOOOcdOOOOWN W Z C. O @ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. .M. M 2 2 a 3 O Z N N 00000000o0000000o N 2 = Z Q > = = N 3 we@OOO@@cC@odoccm 0 >0 9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. m. e e C 4 4 e = Z w a 3 = a N N C0000000000000000 Z e o Z N t = e Q = 0 0 0000000000@O0000@ > = m = Q > 0 00@ 00000000000000000 4 N Z = c. C000000o000000000 2 = - - U 3 w 3 Z N e W w e e @C00000000000@O00 c e C. O T o.o.o. o.o.o.o.o o.o.o.o..o. o.o.N. O C 3 = O Z Q a O ooooooooooooooooo g >o w a - - c v= s O o = .> => w o e J = 24 = U C0000000000000000 J > >> > > w 40@ 00000000000000000 2 a sa g a m = = 0 0 00000000000000000 = - Oz o w 7 6 o zw C0000000000000000 o C. O T. 00000000000000000 O wJ g Z w yv O C3 Q O C0000000000000000 w w 42 o u = 4 3 2 O VZ 5 w t O =D Z L /m JO E = [ m CI o J \\ W DJ 4 44 U w w W W E 3 E E xd = v w ZWZ Awe OEe ZBZ O W 4 4 e ZZwWwee@Ae333ZZZ> J I> c 4 <a C Q Eo Om

/ \\ ,l v G N O.T.W.m.N e. .e. s.@.@.M.e.T.N.N. <m 3 -N-NN@@@MMMNMMMNM J MMOT@eNe@NeeCo-Nm N.N.o.w.=.N.T.M.N. c.N.N.N.T.T.@.c. 4> O 0000000000000--ON 00000000000000000 004 00000000000000000 >Z + 0'0'0'0 0 0 0 0' 0' 0 0 0'0'0 0 0 0 = 000000@T00000000@ C. O O. 00000000000000000 g O e e C0000000000000000 w C Q C000009@C0000000@ U = C. 0 @. 0 0 0 0 0 0.. 0 0 0 0 0 0 0 0. Q. w > c. N N 00000000000000000 M 2 O COCOO@M@@@OOT@Oce w - C. 0 @ 0 0 0 0 0 0.N.0 0 0 0 0 0 0 0 0.@. > e w 3 00000000000000000 I Z O OOOOO@@@@@OOOm@OM

00@ Q O. O. O. O. Q. Q. Q. N. Q. Q. Q. Q. N. =. Q. Q. o c 3 0C00000000000000-w w i a e e O@OOOOOOOO@c4MTO@ O @ O O. C.0 0 0 0 0 0 0 0 0 0 0 0.M.=.O.u. x o w ~N W Z A T T 00000000000000000 ./ s = 0 Z m = 3 O N l .\\'/ 2 4 = 00000@O009009@@ON e s C. >0 4 0 0 0 0 0 0 0 0 0..0 0..0 0 0.T. U 3 A > 0 W 9 9 00000000000000000 w 2 = Z = 3 O O COOC#OOOO@O4SmMO-40@ Q Q Q C.Q.Q. Q.Q. Q. Q.Q.O.O.O.N.O.@. w = c U w M M 00000000000000000 w w = a g U = w OOOTO@OOTO@TT@eT-Q C T. 0 0 0 0 0 0 0 0 0 0 0. =. =. ~. N.. ~. 0 6 w 3 0 Z < M M C000000000000000-O Z w 2 = U w 3 2 O 0000@O000@c0@@T4-3 O Z N N 00000000000000000=* N w Z @C@ Q Q Q Q O O O O Q Q .C.O Q N Q e Z Z a a

    • =

N 2 = Z O > = = N 3 T@O0@O0@@@O0@T996 C. 0 9 .Q.0 0 0 0 0 0..0 0 0 0.N..~.~. u e e U A a = U 2 3 h N 0000000000000000-Z e O Z N 1 O m O = 0 O@O4COOO4 COO @OOmM > = M = O > Q @C@ 0 0 0 0 0 0 0 0 0 0 0 0 0.C.0 0.M. 4 N z 00000000000000000 2 ~ N

=

E w 2 U ^ w T Z = 0 w 6 TO@OOOO@@@cmO@@@e e M 3 3 - 004 0000000000000000T 0 e Q O Z O e Q0000000000000000 O a WO w 2 I U= 2 O O = 0 > => w o > J = E4 U @O000000000040@@Q 4 J N >> > > w @C@ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.N. 4 Z e g c 0 0 00000000000000000 = = = Q2 O E 4 7 6 Q Ew C000000000000@C04 O O wa 009 00000000000000000 w gu g Z Q 03 O O C0000000000000000 w w aZ e U C 3 E g% O UZ 3 w j \\ s O ~3

  • a

= JO G J I E mI O. (, w 3.J P 4 a a< U w w w w m i e a > U w ZwZ Awe e3A 2BZ O W ( 4 M ZZwwWAMOWABBBZZZ> J I> e < <a 4 0 30 Os

m ( I L J' 2 @ @ N.N. @. M.O.@. @.e.N.T.=.N. M. @.@. 4c 3 N-nan @@T@MNNTMMNM J a@NM@m@@NetM@ONM= @ = @ N.O. M. N.4.T. M.=.N.e. @.N. M. T. 4> O C000000000000--Ce 00000009000000009 006 00000000000000000 pg C0000000000000000 = 00000@O@O00000000 C. o m. o.0 0 0 0 0 0.o.0 0 0 0 0 0 0 0.~. g O e C 00000000000000000 w O o 000000@c@C000000m U C. 0 @ 0.o.00.o.o.0000000000.. w > c. e N N 000000000C0000000 %e E O 000009@O90009000-w - C. O @. 0 0 0 0 0. ~. ~. o.. 0 0 0. =. 0 0 0. @. > + 3 w G C0000000000000000 I 2 0 000000@94@O049@c0 = - O C. O @. o.c. o. c. o. o.=.~.o.o.o.o.. N. o.o. @. o 3 W 4 00000000000000000 w t 4 6 e COOOO@g@C@ COTS @C@ i W Z M 4 T. 0 0 0 0 0 0 0 0 0 0 0 0. =.o. o. 0.@. Q C. O @ x o w 00000000000000000 7% {' \\ e = 3 2 N = 3 Q / OOOOOc@C@@OO@@M@c g i w/ K 4 = C. 0 9 C. o.c. o. O. c.c.o.c. c.o.o.. .N. o. m. M 4 U M > Q w T 4 00000000000000000 w a 2 = =m o Q @O0000000@OT0990@ m c

o. o.o.o.o.o.o.o.o.o.o.o.o..N.o.@.

w = @O@ U w M M C000000000000000C w w L M U = w @O0000@@@@@O025@- C. 0 9 - c.o.c.o.o.o.o.o.o.o.o.o.N.N.O.N. Q w w 3 C Z 4 M M C000000000000000-O Z W 2 = U w 3 a O Ove@@o@,C@o@@@,@N w W Z @O@ C O N o. o.o.o.. C.O.O.Q.o. o. N.O.N. 2 2 4 =>. 3 0 2 N N 0000000000000000= m a = 2 o > = = N 3 MO@cQ@O@OC@@@9@@@ e e U C. 0 4 N.o. o.o.o.o.o.o.o.o.o.o.o..c.o.m. ee n = w = 3 1 N N 00000000000000000 2 A 0 2 t = = 0 e Q M

0 9@c@OccQOOOOS@OOM >

Q > 0 00@ = o.. 0 0 0 0 0 0 0 0 0 0 0 0 0. @. 4 N 2 Q0000000000000000 G ~ = - - w g 3 U = A w I 2 - d w I M O@@c0000000@@C@C@ c e 3 3 = 004 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.N. o eO O E O a 00000000000000000 Q a >Q w a - - 0 = f Um a O C J = > => b o e U OOOSOOOOOOOOO@O@T 4 a 24 0000000000000000N. N >> > > w $0@* E C 0 0 0 0 0 0 0 0'0 0 0'0 0 0 0 0 e 3 O ^ = = = Q Q w QE O E O 4 7 EW 0000000000000@O0@ o C. O T. 0 0 0 0 0 0 0 0 0 0 0 0,0. . 0 0. o wa g 3 av Q 03 O O C0000000Q00000000 w w m W 42 3 a W 3 w f% Q u2 2 a 4 0 =3 l JO E = \\ E CZ Q J 4 'd w 3J a 44 U W W W W B B B 3 > = U w ZwZ AWA ABe ZBZ Q W 4 4 e 22www@@eee33332Er J I> C 4 43 4 0 20 Om

l ~ ~ V. E M. o.h. N. T.m. e. N. T. O.m.c.a. .N. =. N. 4e -3

==*NMMTTTv=NNMNNM J N=OveeNNommNacMTe N.T. h.e. e.M. Q. c. @. m.e.N. N. N. N. e. c. 4> O ~~CO*McM=OO*M@cNO g C00000000mO00000@ C. O L C.0000000000000000 >2 m = 00000000000000000 1 0009000T40000000M C. O m. . 0 0 0 0 0 0 0. =.O.Q.0 0 0 0 0 0. N. g 9 O e e 00000000000000000 w O O 000000hh@C000000s U = 0000009T0000d000= W OOm* 0000000000000000~ o. m ak

  • * * * *++ * * * - * * ****

N N %ea O OOOOmNmNeccomecOM W =

c. po m.
c. o. O. O. =. T. e. c. M. O. O. O. O.. O. c. e.

i > e 3 W 1 3 0000000000000000N 2 O COComONNemOOM9mC@

O C. o m. O. C. C. O. O. W. N. c. N. Q. o. O. N. =. =. O. T. C 3 W W W 000000-000000000M W 4 4 e OOOO4eMMccOOM*mO= 0 W O m. C.O.O. O.=. M. M. M. O.O.O.Q. N. @.=.O. M. 4 O W ep W I e T T OCOOOOOOOQQQOOOON a = 3 2 Q ( =. 3 o m OOOOTmammmome=mee g E 4 = O. C T. - C. O. C. O. *. O. W. N. C. O. O. O.. @. o. O. N. e e v p e > Q W T T COOOOOOOOOOOOOOON W G \\ = 2 = 3 0 C COQcom=NTwevemOmc c.o m. O.O.O.O.C.a @ M.=.=.C.=.=.@.e.C.e. W = e O j W W M M 0000000000000000M W W 4 5 V I' 4 = W COccMMemmmmm@McNO ~ C m 009 C. o.c. o. N. M. N. =. O. O.O. O. @. =.m. o. c. > w 3 0 2 4 M M C000000000000=O09 I o 2 W G = U w 3 E O OmmTTNMace@NNNaem

  • e W

2

c. o m.

C. O. O. =. N. T. M. a c. a c. t. v e. c. N. O. g 2 2 g 3 0 2 N N C0000000000000004 O E = 2 O w > = = h 3 m mMmesm992OmTN@N@Q

0. >0 9

=.M.O.N.M.T. =. =. C.=.O.=. w. e. c. c. @. s .e T. U e e m a W E = E N N 00000000000000009 2 e t = Q Z ~ e C = O 0 eMTeem*Mecomm@cNe > = M = Q > 0 c.o m. M. N.a c. N.o. . N. =. Q. =.=. =. c. e. c. a 4 q N 2 = c. 00000000000000009 E

*

U 3 W E K 2 O e W v W 4 W MNemc9mTQcec9khma e C. O T. N. c.N.a c. h o = = Q N O. N.M w a t O e 3 3 = O O 2 O e .=* 0000000000000000M 0 1 a >O W G

Z Um E O O = 0 > => m o e J = 24 = U N9mvcQcocOTOeM@MS 4 J 4

c. >o m.

T.N. C.=. O. O. O. O. O. O. =. =. M.M.M.M. c. h W 2 > e ed 2 O e a = = 0 W C0000000000000*CM t = 05 O w i = 4 7 E O a EW C000000000000mO0m O C. >0 4 00000000000000000 t-O WJ E 2 v 0 3 O O C0000000000000000 W W 2 O j = E C.O i U2 W A E O =3 2 G JO E l ~ a E eZ O J c W DJ 4 - 4 44 U W W W W 3 3 i u W ZW2 ewe eBe 3 O W 4 4 e 22WWWeme@eB3 2 ZM J 2> e 4 2 4 O O w r i

I s ? i ~ -[ ~' I t E

m. e. =.@.C. @. M. 9. @. @.h. h.h.@.@.C. O.

i OOa=NNNMMNaN*===N J h@@@h=he@hme==@@w T.O..=.@.@.@.*.T.T.O.@.N.4. M.e.t. .L 4> O-COOO=N"==O=N@t*O@ ( N O. O m, 88888888888888888 i S = C0000000000000000. k 00@ 00000000000000000 00000o00000000000 >.. 00000000000000000 O e e w O O S: .O 88888888888888888 00@ N C0000000000000000 l e i l = 0 t 0000000@@@O00000@ w = H C0@ 0 0 0 0 0 0 0.= O 0 0 0 0 0 0 0 N. W E a a 00000000000000000 2 O C000040994900090@

O O. C S. C. O. O.O.Q.Q. C.=. N. O.O. O. O. O. .O.@. .O 3 w 00000000000000000 't f w I 4 e OOOOOOS@tOOCM@OO* O @ O S. C.O.O.O.O.O.= O.N.O.O.O.N.O.O.O.e. X O w W 2 e e e 00000000000000000 b 8 ( E g 5 4 = COOOOme@40@M@@@C9 a O O T. C.O.O.O.O.N.O. C.=.C.O.N O.O.O.O. m. N, m => f M 4 u d > Q W T T 00000000000000000 + W E f 3 = = E O O OOOOOMM@@C@M9@@OO @C@ O. O. O. O. O.M. N. C.O. O. O. N. =.C. O.O.N. W = r O u w M M C000000000000000= i W w { 4 4 W 4 = W COOOe=TS@@OhmSOO" t O m 004 C. O. C. O. N. @. =.C. O.O. O. T. O. O. O. O. S. g j w w 3 O Z < M M 0000000000000000= ( O' 2 W I g = u > i 6 3 z o-COOOM@h4wotame@@e 3 O E N N. C. C. C. O. N. @. M.Q.=.O.. N.M.M.O. O. @. O T. W 2 @C@ Z 2 4 j COCOOOOOOOOOOOOON 2 O N z = t, k

N 3 OOO@heOSCO@ TOT @@@ e e U 004 0 0 0 0 9.M. 0.=.0 0 0.=.e.9 0 0.=. a = . w e a j a E = 3 N N 0000000000000000M E A = > + = 0 E i W O = 0 i 0 COcc@@e9@@@9mMWOO > = M = a O > Q @O@ C. O. O. O. O. O. N. =.O. O. Q. =. =.O.Q.Q.N. r d' - N 2 r = v. C00000000000==00M 2

*

e u B w a T 2 O A w w a M @we@ehM@@C@@MvhMh e e [ 0 >0 9 = O..O.M.T.M.O.O.O *==et MS O e 3 3 = + 4 O O 2 O e a * * * **=* 000000000000=O00T O a 50 w 3

Z Um a U O = 0 > => b O > J = v 24 = W e@@Of@MO9MN@hMcN@ ( J h k > w @O@ N. O. C. O. O O M.

  • N N T. e.
  • C. M. T. @*

-i e WM 2 O A E 1 = i j = = 0 0 000000000000==O0@ O2 O w = 4 7 w O I = EW 000000@O00004@O04 O p O J COM 000000000000*000N O b d bbbbNbbNbbbbbbbbb w I u W M O V w I a O = z a s = J e a e 5 J i, < w p. r = 4 m4 U W W W w B B + U w 2W2 MWM MMA 3 O W 4 4 e 22WWWWMWMHB3 E Z> J e 4 5 4 O O m 5 i 1 r t )' a J ) ,.n n,-,

1) -~ / ? \\ \\ / v 2 N. N.W.@. N. N.N. =.9.t.h.e. @. =. @. e. @. 4c3 ocoo==CNMNoooN=o= J 990@@TMo9MNONNeek =.~ o.o.@. s. m. e.m.=.T. h.o. N. M.N. T. 4* O CococcoOQ=ooN=ooo C0000000000000000 004 00000000000000000 WZ C0000000000000000 = 00000000000000000

c. o m.

o.0000000000000000 g O e e 00000000000000000 w oo 00000000@o000000@ U = w k 00@ 00000000000000000 m o N N 00000000000000000 e 3 o cococcoomtoco@oom W = d 00@. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. =. w 3 3 00000000000000000 Z o cocoooce@@ooO94cN

O C. o m. o.c.c.o.o.o.o.o.o.o.o.o.o.. c.o.t. o 3 W 0000000000000000o w a s o e 0000000099000@o0M C

c. o m.

C.0 0 0 0 0 0 0. =.=.0 0 0 0 0 0.M. g C w W Z A 9 9 00000000000000000 N gg t / g e = 3

  • M f

4 = B o t i 0000000m@900o0003 e (f a 4 = C. >0 9

c. o. c.o. o. o. c. o. o.. c.o. c. c. o. o. N.

p e a v M > o w 9 9 00000000000000000 w 3 2 = =m o o o0000000000@c@o09 w = co@

c. o.c.o o c.o. +o o o o o. o o. o. N.

e o = >. - + a U w M M 00000000000000000 W w e a G W = w ocoo@oco@@ococcow C. 0 9 o.c.o.c. o. c.o.o.o.c. o.c. o. c. o.o. N. c w w 2 o Z M M 00000000000000000 o Z W s - u > w 3 E o ocoo@co@o@oooooog o w Z 40@ c o. c. o.o. o. o.c.o. c.o.c. o. c. o. o.n. Z Z a + 3 o Z N N 00000000000000000 o e a = Z o > = = N 3 00009@o00000@900@ C. 0 4 o.c.c.o.N. o.o. o.o. o. o.o. =.=. o.o. @. a e e o. u e n = w 3 9 2 N N 00000000000000000 Z A = 0 2 > + = = 0 A o M = o @coom90$o@o@@@@90 > = C e o @o@ 0 0 0 0 =. =*o.0 0 0 0 0 =*=* o 0 0 N Z - + m > 0000000000000000= =

=

w a 3 U = A w I Z = 0 w + W ocooMM@o@@@@eMo@a e A o e C. 0 9 o.c.o.o. M.N.o. o.o. o.o. o. M. N. O. C. @. o 3 3 = o 2 o a C000000000000000- o g wo w 2

0 v

a o o J = .> => w o > [ 44 U 090$mMMNSN9-NTM9e 4 J N w @om Q = o.c c M N 9 N.9 N @ = N N.a. Z 0 0 0 0 0 0 0 0 0 0 0 0 - 0' 0 0 9

e @A E o + = = = 0 o a = om o E Q 4 7 @o00000030@@@9 o 0000000000000. 000 = EW 00N C wa 009

  • e a

2 gu w o 03 o o C000000000000000Q w w e w 42 3 a = 6 3 w es o UZ 2 4 / e o =3 1 = J G J \\ a e o %/ w 3 e ~ 4 44 Q W w W w E E B B > Q w ZwZ Aw+ ARA 21Z o W 4 4 A 2ZwWw++@AABBRZZZW J Z> c < ( g 4 o G w

p- / \\ 8'u s' a @ Q N.h. e. @. h T. M. c. @. @.@.a T.W. @. 4 e O

  • QQQ-QQ*N=QQNNo@*

J OO@teMeM@t@@MN@he Q Q Q w M.M.M.N.M.=.=.=.M.g o.M.k. 4 O 0000000000000000M Occo@OQQQOCO9COeh

0. p g 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.

. N. 06 C0000000000000000 = 00000000000000000 00@ 00000000000000000 g O e e C000000000000000Q w O O 00000000000000000 U = 00000000000000000 C. o @ w > e Q 00000000000000000 N N A E O C0000000000000000 w

  • d QQ@

C000000000000000Q* = * * **- - *

  • C000000000'0000000 w E 3

Z Q QQOOOOQw@cQCO@OON = - Q 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.N. O QQ@ W 00000000000000000 w i L 4 C000000000000@O0@ A f g Q w C.0.o.0 0 0 0 0,0.o.o.0 0 0 0 0 0 Q @c@ g W Z A 9 4 00000000000000000 M M k i = c g l = 3 O C0000000@C000000@ = 4 = 00000000000000000 p a C. 0 4 w 4 y A > Q w T 4 000000C0000000000 w a t = C000000000000000c = z Q o 00000000000000000 @ Q S. = wg Q U w M M C0000000000000000 w w L 1 U 000000000@c0@c000 = w C. 0 4 0 0 0 0 0 0 0 0 0 0 0.Q.0 0 0 0. Q w 3 O E < M M C0000000000000000 Q Z w a

u

C000@Q0000000000@ w 3 2 O w 2 @Q@ 0000000000000000Q N N Z 2 L

  • = s
  • * - * = * ~
  • M 3

0 2 N N 00000000000000000 2 = Z Q > = = 90000000000000009 N 3 C. 0 0 0 0. o. 0 0 0 0 0 0 0. o. 0 0 0 m e a w v QQg e n e = 3 w 2 = n N N 0000Q000000000000 2 A Q E = Q > + = A Q C0000900@c000000@ > = = M = Q C > Q @ Q S. 0 0 0 0. Q.. 0 0 0 0 0 0 0 0 0. C. *. 4 N g 0Q00000000Q00Q000 m >

=

a. 3 A w w a u Z T CQ0@c0000000@@QQ@ c A w

  • A O C 3

= C09 QQQQQQ-QQQQooCQQN< Q Q C 0 0 0 0 0 0 0 0 0'0 0 0 0 0 0 0 2 O e 2 >Q w a - - = Q Z U= a O O J = > => w Q > co@@M@e@@@@SSMmST 4 J = u d 24 @ C S. Q Q o.O.N.Q.N.=.*.o.=.=.=.N.o. .M. h >> > > w g > = a se g Q m Q Q C000000000000000N = = a Q3 0 m Q = w 7 0000@Q0000000000@ Q Nw Q wJ QQ9 0 0 0 0 0..Q.0 0 0 0 0 0 0 0 0. = m 2 w yw w w 0 03 o C 00000000000000000 D u LE 3 2 e /,, Q 3 w O v2 Z 4 6 O = J E J \\,. = m Q 4 w DJ 1 44 y w w w w 1 B B 3 > u w ewe AwA ARA 2RR O w 4 e e ZZwwwedeAABBEZZZW J t> C ( 44 4 Q Q w

i \\ l h I a @ @ e. @. T.N.o.=.@.N. e..N.N.4.N. e. 4e 3 --=*Nmggmm=NNNNNN d @@4@@NN=@@@@~@Nko e.*.@.N. T. =.@.h.T.@. =. T. @.=.T. o. o. 4> O ?N**@e@@@mmDN@oCo e =.. = o e CooO@co@otoo@co@c C. o w C. 0 0 0 0 0 0 0 0..0 0 0 0 0.. 9 >g = coooooooooooooooo oco@o@@m@ooooooom c.o m. o.c. o. c. o.c.o.N. o. o. o. o. o. o. o. o. t. g O e e C00000000000o0000 w oo Ooco@@cNeocoo@co@ U

  • w >

oc@ 0 0 0 0 0 0 8. @.m.0 0 0 0 0 0 0 N M o a> 5 N 00000000000o000o= ma o ocoo@@-o@@eceN@of w =

o. >o @

C. o. c. o. =. @. m. e. N. . o. c. h. m. o. o. @.

  • e 3

w 00o000-0000000009 3 2 o Coco @9@@@ econ==ow = = o 00@ o.c.o. c. o.s.v.@.@.m.o. o.@.g @ o. m. o 3 w C00000-o00000-00N w 4 4 i e ocooth@NNM@@@NNom o

f. o m.
o. c.o. c. a v.@.t.w.N. o. o. @. N. @. o. e.

g o w ( w 2 m e e ocooooooooooo-oo, a z e i = = 3 o m s%d u 4 = co@otN@NeN@NogN@@ g

o. o g o.c.o.o.=.T.@.4.M.v.o.m.h.@.@.c.

A < v A > c w T T oooooooooooooooo@ w a = 2 = 2 o o coo @TN#-@e@NNa@@m @o@ o.c.o.o. =.@.@.@.~.N o. @.@.g g o.N. = = e e C U w m n ococcoooooooo==0@ w w 4 2 U 4 = w SooW@eNeNmm@w@@~@ w o.o. =. @.@. g m.t.e.m. e. @.@. m.N M.

o. o g.

c w w 3 o Z < m M C0000000o0000==c@ o 2 w g = u > m B 3 o o@Ne@m@NMNkD@@m-N W Z

c. o m.
c. a v. N.N.=.5 9.N.e. m. N e. o. o.@.m.

e N 2 2 4 3 o 2 N N ococo-oooooOQ--Q@ z = Z o > = = N 3 @Nmmme@Newmco@o@w

c. o w

@ t. N. m. =. @. =. T.N. N m. @.=.c.e. @. a e e w U 6 g = z w = 2 = a N N Oooo-ooooooo-Nooo Z e 0 2 e = = o e C = o @Nm@mhNNMemegmS@w > = m = C e o @om @ M N. =. o. g g t m. .M. M.@ e.e.@. @. N 2 .e 2 Coco-ooooooO==com ~ > w = = = U Z 3 w g T 2 = A w 3 w i M --NM@ThemgNNN@c-N e A 3 D = cot @ @ @ m h @ @ N N - @ v 3 @ o. @.c o eO o 2 o a .+* 0o000000000c===o-o s eo w a - - 0 I v= a o o - = > => w o e J = U CNTNeN@o@o@9@m-NN J sd W T. =. T.m.@.e.N. N. e.@. @. @. e.=.=. @. N w @o@. cocoooooooo-N-Na@ g y e ed g o e = = o o = CE o w 4 7 s o EW @ofo@@@oo@@@mNo@c o o wJ 004 C. o.o. o. o. o. o. o.o.o.o. C. N. @.c.o.w Ey g g J o o3 o o C000000000000000-w w J - 42 e v 4 3 a f~'N o ur 3 w j i o =3 2 4 i JO E = t '-] E mI o J \\ w 24 ~ 4 44 W W W W W 3 E E E > V W ZwZ @wA AB6 ZEZ o W 4 4 A Z2wWWAMcAeBEAKZZ> J Ik e e <s < C o N w

. /, $Y M e O w =@ = e M O 9 TM T 0 M = = e h s h h e e T C O O O O =0 0 C O = h O 9 N MW e e N = N = = N = NN O O = M M I O C0 hO 8 = = = N g O O

=

= 0 = = m 9 N CO

= 0 0 No M N O O \\ = 9 N = @N M e 9 = = *

  • O O

=0 O

  • e

= N M@ h N = N O = N = NN O M = M i I h e S O 00 N = N l O O O O -== = = = = SNOe@eehechNeCoceOOMOe= men .N NMeehehe 9@N=M@=OgN@==@ 9=MONONN=O=NNO 99W@NO@T9 hhhoh@wehhoheh hC=gwehhhehhoe O=MMST=N@ OOO-QOOOOONCOO CON =OOOOOOOOO= ON-C=O-NQ CO@909meh@=h0N@@=mM99NhhMOhg=e= McMhSNNS= OOO-NNOO= NMO-NNO==NNNQQ* NMO-NNM NO*NN===M OchhhheteeE@S99COOOOO=====NNNNN heese===N 000000000000000================ 00000==== COhehMN@@e@O-9NoveON@COSe@McN9M w=@NMhhe@ OQ==@OOgg@CNM=OOT=@M=O9MN@@g=OT MOMOMO=Na i SOhhee@@e@eMTehdhhMOOOcehhech NhNNNMONM l -N===============O-NNNO====N= O==N=Q==O l MeNewMoewCoMQew=e@NweeeNOeMOhM= McMeeNNe= e CooO= NMO =NNO==NOO=NNNNQ=NNC==Mn NO=NN===M e S 4 i

  • e NWhhhhheseeeemeOOOOOOO-===NNNNN heseS=*=N T00000000000000================

C0000==== 00=====================*=======eNNNNNNNNN8 i C000000000000000000000000000000000000008 S ehNMW@@he@C=NMg@ he 90=NMe@@ hee So=NMTT@@@ Whhhhhhhhhh O======== i 00000000000000 00 00000000000 600000000 hhhhhhhhhhhhhhhhhhhhhhhhhhhhh hhhhhhhhh esecessesseeeeeeeeeeeeeeeemse seesessee Th

  • =

1 4 1 ,1

y_________ f i i \\ / /"% D i M \\ l \\ m> h a w a = 3 w Q 3 23 h O E 2 w 32 = 4 h

  • e E

O O = w N. @. c. @. T. M. N, T. =. h M. O. N. M. N N. N. M N. M. % N. M. @. T. T. M. N. @. e. h = N. M. T h o. @. M. @. =. N. =. =. @. e.. O. @. N OQ = =0 =O=000==N=00==O===a***=0C0000========OC0====O0==O hw I a e e s el ee a e e i e i e a i s t I t i e e a e a J C0 N 3 m 7 0 h e T.M.@.@.@.M.M.O.M.N a @ @ C.M.N.M.m.e.@.M. c.a @ N.e.N.=. N.C * @ N.M. p p @ @ M.O.M.T.h.h.m.@. N. M M. 00 w aw E 3 00 WOm@OcTT@MN@@TeThheMNO*Oe=3hN=hNmO@TS@O=NemO@C=== 3 moa -Nehhteme@v==TTT@N@@eheh@MNQa =OO*==NNN==NNMMTM w = e N

  • NNNMNNNNNNNNNM M

=*=e=e

*====

d 3 3 = w >

h. h. =. O. b. v. @. h. N. M. @. T. e. e. @. M. o. v. e. c. O. M. @. N. h. m. o. m. e. M. N e. h. e. h o. @. N. h. o. e. T. M. M. e. e. >. @. p e a OI w

h W3 sh@@@MNNNMNNMNNT@hh@hh@TTTTMNNTMM*T@@@eC=-OmpSh@@. q q =4

==

p w e 3 / w ld W. 0 = ~ e T = N e,4 @ h e. C = N e T @ @ h e. O = N M T - N M T @ @ m e. O

  • N e T m @ h e
    • NNNNN

==========NNNNN

=

h

t, i f a O i P r E w b G 9_ 3s i. m 9 W w 32 3 i 33 9 r N r @ e. M. e. h. e. @. M. T. e. @. @. N. @. =. Q. =. 0. N. N M. N. *. *. @. h. @. M. e. N. O. O = @ = = al e. r e p 00000000000000=========*000=Q0===O*=e* =. n i e e i I 6 e i e a e e e s # 4 P .a D I @p. h. @. =. @. O @, h. @. O. T. N. N. O. *. 4. O. T. @. M. N. @. T. @. c. M. N. 9. @. @. @. h. 9 9. =. M. C. 7 j h@hMOON==@g-@@@eoeeMO=MeNNMWMeeO@^ce=h TOM N N N. 9 @ T @ @ @ 4. @. w N. N. @. =c e A. @. g M. T. @ c N O @ N N = = r, @ h h. a h

== .e==.. .NMMe New NN t tal i i 3 I ... e.. M. h M. 4 . O. e. @.h.h @ w M N ....... e... =... h. e. h M. o l t m>*@@h9@@ee@cgA@eh@c@h>0@@N@@MNWMNN-hNe p. M 9 = f i O O e N M W = N M g c @ h e @ O..= N M 4 4 @ h e @ O = N M 9 = N M T e @i e }

  • NNNNN

=*w -=e=NNNNN l' 4

/< \\ \\ / N/ i I i i f D i m t \\v W h 32 I wd O 3 N 36 33 h O E I w F .Z 4 h h e 2 Q = v OW T. M.... T. T. N. N. @ N. M. N. O. T. @. @. @. @. @. h. d. T. M... @ N. N. M. N. M. e. e. h T. @. e. @. @. C. h. e. h @ M. M. N. .d C0000000000000 0000000000000000000e*C0000 0000000 hw a e e e e e e a e e i e e t i a e

  • 6 t 1 6 i e a e e i e 6 e t 6 s 6 J

GQ M 3 7 r O he 00 e.T.T.S.@.C. e. @. T.. T.. O.N.N O. M.h M.. C.O.O.G.M. e. e.. O.T.h @ @ @ h N. M. @. @. e.h. c.. m. M. T. N. O. w w 3 OQ WeOM@ev=ON@@N@e@@@@@CNS@MS@N.0@. SNhTNe hhheO@OMehN R B @ @ @ h. G. N N. h T @ w @ h @ T M. T @ @ @ @ @ @ @ @ M.i a: e.s h T =, @ M. M T h. e. e h. @. @. h. h. @. @. h. T w N.. .....g c h j 33 0 2 .I W h OA T. N. T. @. @. k. O. T. O. T. @. e. O. @. @. O. @. @. C.. M O. N. e. @. N. d. h. @. T. @.. s. h @ N. e. h. h.. N. o. e. @. N. T. e. N. @. Z M a W h M3 . @ e O. S @ @ h e e h @ @ e O. N. @.T e h. h. h T N. N. N. @ e O. N. C. e @ T h e @ N. @ @. O. O. O O. @ e h a 3 W 5 O. N M T

  • N M T @ @ h e @ O.. N. M. T. @. @. h e. @. O. N M T. N M T @ @ h e @ O.. N. M. T @ @ h. e. @ N

.C WR ,3 3 NNNNN NNNNN A

r f l i' a t I i l I \\ l l t F t M r I l \\ m t 1 I P 4 i r t i 4 F l I l I = = = M. v. M. h. =. =. M.,. 8. @. e. e. C. a. O. m. e. h. h. c. =. =. =. =. N. M. e. e. O. N. O. N M. e. =. N. M. N. M N. Q. a c. e. @. w. C. N. o. m. c. M. 1 000000000000000=O=C000000000900=== OOO=========OO=MMMMMM e e e i e e a e t 4 4 4 4 e a e e

  • 6 i e
  • 6 4 e t I i 6 1 eo i 1 4 6
h. e.
c. @. =. N. =. O. c. @. M. =. N. e. h. e. @. h = C. h. e. M. e. e. @. S. d. N. M. @. h. e. h. o. p e. e. c. h. e. >. @. =. c. M. =. M. e. g v. e. c. e.

@9ho@909N#O@MNh0ToehMhNONhN9she@=9@9N@gTTM==@ceTOMh@d@@ T=O @hhh=NNNMMMNNNNMMMMMMMTNTMN====@MMMMMM9999@wggwNd@gO =**NMMMMMMMMMMMMMMMMMMMMMMMMMMMNMMMMMMMMMMMMMMM M=====e t N. @. O. N. M. e. p h. 9 9. C. *. e. =. M. M. S. @. =. 4. e. M. N. e. e. 9. h. T. M. O. N. S. O. d. =. @. h t. m. O. @. 9. M. =. e. =. M. e. m. e. @. N. c. N h. eachpHNem>@@gehappoch@@gMcMNNMM-NNetwe@@hehhh@cgN==NN9ee = = i P I 4' -NMW=NMT@@heSO=NMWe@heSO=NMg=NMT@@hepO=N394@hapC=NMw=NM NNNN

==========NNNNN

==========NNNNN L l h

O 4 I a l e O l T I e i m a N l-w 3 l 2 i

== 2 h %3 h

  • h. FI. *. N.

Wp NOOO* 9 e ,J3 N. e. 4.. O. 1 @ 06

  • O 8 hhe9@

pp am N em W ,F b N. $. p @W h P^ O ...h. i i 'l I l '"hN"NN ..m AL m,_

3 rh [ \\ \\ l \\ / h b l I e f i, rh M / 6 (' we t' h l I W I 3 2' 2 3 Wd b a e E3 m O E Z wI e q h > e 2 O e I u o @ 9, 9 0 9. e e 9. e N. M. N. e a N. @. h. O. @. O. e M. @. O. 9. N. *. M. e o e e N. M. M. 9 9. N. M M. M. M. @. @. e. h. @. e. @. O tJ ? e e I eJ O O O O O O O O O O S O u O O O O O O N N N e== 0 O O O O O O O O O O O O O u o O O O O O O O O O I kw e e a 4 e e a s e a a i e i e i e ea e i e 6 a a e i e i e e e a i a e 4 s e a e e e i t .a G0 9 3

t s'

O I he

b. O. N. e. @. e. N. @. N. e @ @ @ O. M. >. @. 9 0. e. @. 9 9. @. e. M. M. O. O. @. 9. e. @. @. e. 9. e. e 9. N.

Od g w l 8 E OO MN@h@P.M9@M9@@@ehoCh@MMMO9OSSN@MMM@Me9@eN9O@NM@NO@ l 3 @@@@@@@@@@@@@hh@hh@@ @999M9NNMM994@@999999@@@@@ l w e e y eeeee eee ee e eeeeeee e mee eee e eee e ewe v eeeeee eeee h9 I W OI

h. @. @. N. O. h. 9 9. h @ e. 9 9. h. a N. M. M. N. @. p G. @. W. O. =. 9. @. M. =. 9. e.==. e. e. O. @. @. p N. 9 M. M.==. @. @. h. M

[ H E l e e 9 9 M. M M N M M M M M. N N

  • e e N N M M 9 @ @ @ M. N N 9 e h h e @ O O. N N M M M 9 9 @ 9 @ @ W 9 N W

e H3 e m e eeee eeee e e = w== =.= e eeo e ee e=,eeeoee e s 3 i 6 ) 5 i WW he@OeNM9=NM9@@he@O*NM9@@heeO*NM9eNM9@@he@O*NM9@@h. t l 3 e=*NNNNN e== e e o s-== * **NNNNN e en a= === m e e on 1 m i 5 L

..-y h. ~.

p 5

$ k.'4 ,, j f. .t e ~ 18 '13.1 160.7 -0.5 19 12.2 158.0 -0.4 20 - 9.0 '169.9 -0.2 [ ] '21 6.0 .195.4 0.5 t- [ 22 4.6 185.1 2.0 f 23 7.9 179.8 2.2 24 -99.0 -99.0 -99.0 '{ 1 -7.8 159.9 0.9 l 2 7.4 136.7 1.1 h 3 9.0 166.5 0.5 -[ i '4 8.5 160.8 -0.2 'I I 5 9'. I 170.4 -0.1 f ( 6 13.3 180.3-0.2 .] l 7 11.4 175.8 0.1 l 8 8.6 169.1 -0.5 9 10.0 173.1 -0.7 I 10 9.3 485.4 -0,9 l 11 9.3 173.2 -0.8 12 8.6 163.0 -0.9 I 13 9.5 155.4 -0.9 1 14 8.7 141.8 -0.8 1 15 9.9 159.5 -0.7 I 16 12.1 152.6 -0.9 i I 17 10.6 160.0 -0.7 18 10.5 161.1 -0.6 -[ 19 9.2 154.6 -0.5 l' 20 7.6 138.0 -0.2 t 21 6.2 137.4 0.5 22 7.5 140.8 0.7 .[ i 23 7.9 145.3 0.4 24 7.5 145.5 0.2 d 1 8.2 164.0 -0.2 2 9.5 177.3 0.1 3 10.3 178.5 0.2 A 4 11.2 180.6 0.1 l 5 11.7 182.6 0.1 6 10.7 187.9 0.1 i 7 10.3 181.0 0.1 8 10.4 175.6 -0.4 f 1 STOP TIME JULY 20.1987 HOUR 7 MINUTE 20 6 1 4 i i di 1 1 4 1 l T t { J ) i -VI-42. 1 i 1 l ..m.. m,

a- ~ a k %-n; ja A )' i vc, ^ ~ s N RELEASE NUMBER 87055' CONTAINbENT PURGE i STARTING TIME JULY 23.1987 - HOUR 17 MINUTE 3 l TIME WS10 WD10 DT110 HOUR MPH DEG DEG C 1 17 12.0 171.9 -0.8 18 9.7 167.9 -0.7 19 8.4 160.2 -0.4 20 7.4 154.2 -0.1 21 7.6 150.1 0.5 22 7.9 149.1 0.5 23 8.9 ?61.4 -0.1 24 9.1 163.1 0.2 1 9.4 167.5 -0.4 { 2 9.3 180.1 -0.1 3 10.0 180.7 0.2 i 4 7.3 170.7 0.1 j 5 6.5 187.0 -0.1 i 6 4.4 197.2 0.1 l i 7 4.6 309.8 0.5 l-8 4.0 150.3 -0.2 9 5.9 180.5 -0.8 i 10 10.4 205.5 -1.0 f 11 6.2 240.1 -1.4 4 STOP TIME JULY 24.1987 HOUR 10 MINGTE 18 ' 1 I i STARTING TIME JULY 24.1967 HOUR 11 MINUTE 15 l TIME wS10 wo10 Dil10 HOUR MPH DEG DtG C 'l 11 6.2 240.1 -1.4 ? I 12 -99.0 -99.0 -99.0 f 13 6.8 219.5 -1.3 l 14 7.1 198.4 -1.1 15 -99.0 -99.0 -99.0 16 -99.0 -99.0 -99.0 l 17 -99.0 -99.0 -99.0 l 18 4.8 148.9 1.3 19 2.1 274.3 3.9 1 20 16.3 332.7 -0.5 j 21 9.7 353.0 -0.2 22 4.4 249.8 1.3 j 23 3.5 260.5 2.3 24 2.5 247.9 4.6 1 i 3.7 188.3 4.6 2 3.8 281.9 2.0 3 3.2 251.5 2.6 4 2.5 359.5 3.2 5 1.7 192.8 3.7 6 1.6 232.8 3.1 i -h e VI-43 1, -,-

w ~' .,f j , 1. >r ? e j 1 N' i 7 3.0 129.4 2.2 9 l 8 4.1 105.0 0.4 i 9 6.3 '108.8 -0.6 i 10 5.6-109.5 -1.0 f II 5.0 157.8 -1.2 1 12 5.7 160.5 -I.2 1 13 8.5 154.6 -1.1 14 8.8 164.9 -1.0 4 i 15 8.8 160.1 -1.0 -j l 16 7.3 168.8 -0.9 8, 17 7.3 159.7 -0.9 ? 18 6.8 158.2 -0.8 19 6.2 153.3 -0.4 I 20 6.2 156.3 0.3 l 21 5.6 152.9 1.0 22 7.1 155.5 1.5 l 23 7.4 155.0 1.2 j 24 8.2 160.9 0.8 l t 8.0 173.5 0.8 2 8.3 185.7 1.0 } 3 8.7 189.4 1.6 .;J' 4 4 8.7 195.0 1.9 5 9.1 197.4 1.7 6 9.6 192.9 2.3 7 10.1 194.4 2.0 + 8 6.3 195.4 1.0 1 9 5.4 197.7 -0.7 l 10 4.1 184.3 -1.5 l 11 5.8 195.9 -1.2 j 12 6.5 178.4 -1.1 q 13 6.9 170.6 -1.1 5 14 6.0 173.0 -1.1 15 7.9 400.0 -1.0 16 7.5 178.1 -1.1 17 7.2 170.0 -0.8 )} 18 6.1 174.5 -0.7 .I 3r 6.5 158.6 -0.4 5.3 149.1 0.1 O 6.0 151.3 1.0 f 22 6.8 158.1 5.6 3 23 7.6 164.5 1.2 ? 24 7.6 170.7 1.4 1 1 8.8 179.6 1.4 1 2 8'. 3 186.0 1.6 j 3 9.1 185.9 1.4 l 4 9.2 189.6 1.8 5 8.7 192.0 1.3 l 7 6 9.2 195.2 1.4 7 9.7 199.6 1.9 i 8 9.9 204.5 0.8 ) 9 8.9 206.4 -0.5 l J j STOP TIME JULV 27.1987 HOUR 8 MINUTE 53 p i. VI-44 4 I I 3 1

~ \\ 1"' ,/' V L/ (. ' RELEASE NUMBER 87056 CONTAlhMENT PURGE STARTING TIME JULY 30,1987 HOUR 18 MINUTE 2 j TIME WS10 WD10 DT110 HOUR MPt1 DEG DEG C 18 7.9 168.5 -0.5 19 6.3 179.7 -0.1 20 4.7 172.9 1.3 21 5.2 142.3 3.0 22 5.0 124.0 3.5 23 5.9 125.9 2.7 24 6.0 140.8 2.3 1 6.4 150.4 2.9 2 6.4 163.2 2.0 3 9.5 184.1 1.7 4 10.0 186.2 1.7 5 9.0 192.3 1.6 6 9.2 195.0 2.0 7 8.8 200.3 2.1 8 8.0 193.9 1.4 9 8.7 200.5 0.4 10 9.0 194.3 -O 2 11 11.2 185.0 -0.9 12 10.7 180.9 -?.O 13 10.6 174.7 -1.1 14 12.S 169.3 -l.O 15 11.8 178.4 -1.1 16 19.0 178.2 -0.9 17 10.8 171.3 -0.7 18 8.9 168.4 -0.5 19 6.7 155.0 -0.1 20 6.9 149.7 0.9 21 7.7 150.1 1.9 22 7.4 147.4 2.7 23 7 '. 5 148.2 2.5 24 8.9 161.5 1,2 1 8.6 170.1 0.5 2 10.5 182.9 0.8 3 10.6 186.7 1.2 4 10.5 200.6 1.1 5 11.5 206.2 1.6 6 8.4 203.1 1.7 7 10.4 195.2 1.8 8 13.0 196.8 0.6 9 13.2 196.3 -0.2 10 12.8 202.8 -0.9 11 11.7 196.1 -1.1 12 11.9 185.7 -1.2 13 11.2 190.1 -1.3 14 9.6 191.9 -1.1 15 9.8 202.6 -1.3 16 9.4 231.0 -1.1 17 8.2 234.0 -0.7 18 8.2 233.5 -1.1 VI-45

s 19 5.1 248.6 -0.2 20 2.9 279.8 1.3 21 2.2 326.6 2.1 22 1.8 252.2 3.8 23 2.6 279.9 2.2 24 1.7 280.7 2.0 1 2.6 297.8 2.0 2 2.9 284.9 2.0 3 2.3 292.2 0.5 4 2.6 289.6 0.7 5 3.9 299.1 0.9 6 2.9 287.0 1.5 7 2.0 297.2 1.3 8 2.6 296.7 0.7 9 2.2 358.2 -0.8 10 2.9 65.8 -1.5 11 3.4 84.3 -1.6 12 3.9 56.0 -1.7 13 5.4 76.0 -1.6 14 5.9 95.7 -1.3 15 5.4 85.8 -1.4 16 5.4 24.4 -1.3 17 6.0 87.0 -1.2 18 6.9 113.4 -1.0 19 5.5 89.7 -0.5 20 3.6 82.9 0.1 21 3.3 86.5 0.4 22 2.0 106.2 0.8 23 2 '. ' 225.1 1.2 24 3.4 37.8 1.3 1 1.8 87.8 1.0 2 2.1 342.3 1.0 3 2.7 45.5 1.0 4 4.3 128.6 1.4 5 7.8 143.3 2.4 6 7.9 325.6 0.8 7 6.2 139.9 0.2 8 6.2 162.5 1.0 STOP TIME AUG 3.1987 HOUR 7 MINUTE 36 VI-46 i

m., f / \\ t \\m) [h N 4 i e %l w> c T W N D 3 4 Z W 3 W D .Z. d CD a e 3 3 4 E D k O Z I W 2 2 3 Z OI N N Z O u N @ O.O.CD. @.N.@. d.N.@.N.M.*.N.T.a. M.N.N.4.@. CD CV @ @ N O. N. M. @. C. a T. N c0 T a N *

  • N. C. a.

m aO OOOOOOOOa=~~-a COOOO-O==00COOOOOOOOOOOOOOO NW t e e i e e i s I a e a e i a e e I s a e i e a 1 i t a 6 O 00 cD N 3 T C N O G 3 00 N. @. N. @. @. @. @. N. N. . N. C. Q. T. T. N. @. C. @. @. @. cD. C. O. n. c. N @ ~ m 1 @ @ M. M. O. N. tD. O. N< W -W g 2 00 N O - a3 O M N - O @ * - e T T N cD N N o c cc @ e N - - @ N N N N - c @ M @ @ C c - W

    • 3 O M N M M M N = * @ CD @ M @ N.= @ N - - = M N
  • CD (D @ N @ CD M @ cD C N CD T M - M M e tD N

=--==*=MMNNNNN - - -.* M a e - N N -MMMMM 3 W 3 0 2 Z 2 N W N M a CZ C. N. O. T. c. N. M. @. @. @. N. N.. O. N - O. cD. @. N T. O. @. cD. O. M. M. M. T. N tD. @. N. O. N. N. . C. O. @. T. 1 -A O W N M3 M T T T M T es s=.= N a N N N M M o @ N T @ N N W M @ @ T C N @ @ tD W N M N N T N N N .J M 3 A W E 4 WE w9O=NMT-NMT4@N(D@O*NMTccNe@C=NMT*NMT4@Ne@O 33 - ,*NNNN = -ee~~e --NNNNN we N P

s. j ~ 8 m 4 s I V 4 1 E T G U 3 N I E M T U 4 N 1 I M RU 7 OH R U O H 7 8 9 1 7 8 0C 21 531 071.952231.3 4 4 6./ 1 34565875,3946970554.i.. 1 1 04 8 9 1 G 00000000000001 1 1 1 1 1 1 1 1 1 0l 222331 334443 1 1 1 1 1 1 1 1 TE G OO 0 U 1 A GU 0G 833472656426803607733401 320443884924085061 1 A E 1 E .61 940384548205689334574734697304 M 0O 8325337581 1 5341 0486 I w 34 1 81 1 1 21 328233322232 201 1 1 97351 1 1 T 33 3233333332333333333 3333222222223 71 21 1 E G M N I I T T R 0H 88093721.7391 520989438051. 376421 21 1 1 1 T 648591 953282281 7967 P A 1 P s O T 5M 323234531 344l 345532433333333221 1 S W S ER 45678901 2341 2345678901 2345678901 2341 2345678 MU 1 1 1 1 1 1 22222 1 1 1 1 1 1 1 1 1 1 22222 IO TH 4 iiI l 1l

ji ;

l1

l, 9 4 I V 5 4 E T UN I M EG 19 R U P R U T O N H E MN I A 7 T 8 N 9 O 1 C 5754035556976493 1 7 1 1 33321 08741 221 221 1 4 0C 41 361 5685461 1 1 00 1 1 1 1 1 1 1 0000000000000001 1 1 1 1 1 1 3 1 1 G 000000000000001 1 TE G DD 8 U 5 A 0 7 8 37680 461 60433951 6261 7801 753369581 31 1 0G 903472755501 1 E 1 E 738382439594866571 08929277934596421 2041 53286962 R M DD 1 1 883 E I w 5551 621 4331 1 233446666556566678881 052234337521 1 O T 1 1 1 21 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 233 33333 3333223 MU G N N I E T 9 5 2.O.1 276591 4022596867461 892340375634249931 2 S R 0H 79701.. 1 A A 1 P 901 21 021 97534467734665453 E T SM 571 65348533582322444531 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 L S W 1 E R ER 901 2341 2345673901 2345678901 2343 23456709o1 23456789 22222 t 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8 1 22222 MU 1 IO TH j!

l 14 1 1 1 i 4 1 i 1 4 I I 20 2.3 281.0 1.0 l 21 3.1 289.6 1.5 22 2.1 229.5 1.3 23 1.9 273.1 2.7 l 24 2.6 135.1 3.1 1 1.8 186.5 3.5 l 2 1.9 296.8 3.5 3 1.8 350.8 4.1 4 i 4 1 *. e 274.0 4.0 ) 5 2.0 305.0 3.8 i j STOP TIME AUG 17.1987 HOUR 4 MINUTE 18 i l 1 1 1 i i 4 J

l

) i 4 4 i j i I t I i I 1 i i VI-50 i

_. I i t ) i n O .. v 1 e P b ? 6 I b t i + .F M e LM I I m .l I-co I W N 3 l .Z I i I s w 0 z - 3 L G3 N o f Z I w .E. t T N i N e 2 i, o a w o. OO T. e. N. @. @. M. N. a N. M. N. M. =. c. @. N. M. N. T. T. M. =. =. o. @. N. =. M. @. N. 4. N. T. M. @. T. c. @. N. @. @. N. @. @. ID. @. N @ ~ t N =0 oo o oooo oo oo C-= c * = = = = = = = a o ooooOO o ooooo o ooo o o o ooooo i 5w e e i sa ea i i 1 4 I t i a e e e i a a a e e a t-s a a e a e e e a ( r 0. oc l 3 A T f a t .N ~L r l C0

v. 5. @. @. N. t7. M. @. N. O. =. N. N. e. T. M. @. N. e. N. =. @. N. N. @. M. o. N. to. M. o. N. W. cp c.. N. N. @. Q. o. o. N N. @. c. e. o. e.

l w w a .E. oo -no-o@@e@@ceNe@@@NN@@@Me-eNW@@eM@o.TNNece@Nemo@@@ W E =NMMTT@Ncpe@N=@@oaoo0-N@No-MM@cMT@TTceWTeT44TTTTTN e N - = = = = =.= * = = = a - a - N N N N N N N N M M M M M M M M M M M M M M M M M M M M M M M M M N 3 3 0 i Z Z r

== T w N e a o. N. e. T. T. =. N. 9. o. N. . 9. M. e. @. T. N. M. @. T. T. @. @. @. N. O. M. @. c. T. M. to. @. N. e. M. M. T. T. e. tD. N = M. @. o. e. M. o.. q ,q [ w. >= M Ncee@o=NMMM@TN-aco-ao@@MMTONNNT@@@cet9@@@vTMTMMMN .J M E a a a = ===

    • a-===a**

l w t i 2 } l wa @ o - N M T - N M T @ @ N e @ o.- =- N M T o @ N e @ o ~ N M T - N M T e @ N e @ o - N M T. o @ N t.o @ 3 -NNNNN

== NNNNN ---= -.. og p e t l- ? l 1 i i --.-w.-

ljlIf1' N _ "( D 2 5 I V 263807027321 481 446421 6629269757098622267898995656645454 1 11 1 21 21 0000001 1 1 1 1 1 1 0001 21 00001 00000000000000000000000 266487301 8621. .95283451 32751. 8. #. . 3 2 607741 44428873161 493771 1 2205491 61 66563887442790427466785857345031 2730387526381 300900 81 00870008001 41 8036253427735232339361 9221 01 1 8 1 8 1 1 1 1 333 2221 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1 23332233323333 ....90938203591 0304548236944591 5342 06790068737281 9823371 1 1 1 2232222222222323454444321 21 2334221 222455667766788677678 01 2341 2345678901 2345678901 2341 2345678901 2J45678901 2341 2 22222 22222 1 1 1 I 1 1 1 1 1 1 22222 1 1 1 1 1 1 1 1 1 1 ll ,il 'llllll1)llll1l lI Il I

e f 1 1 i e 1 t 8 6 i i r a ? M> I f N kl> 3 .Z. t 5 l C 3 l f I N

4. T.M.4.M.4. @.

QDo 0000000 ~ t I 4 s e t a N O3 (

5. '1. @. @. M. @. O. 4 OmuOsme

@Q@QW@@ i 5 M t l W @M*@@@* L s o @@eh@@h I .4@@-.. l J. I t - ~. - - - - - - _. - - - - - - -,, - -,,, - ~ - - - - - - - - -. - - - - - _ - - - - -. - - - - - - - - - - - < ~ - - -, - - - - -

.] f a .3 ,4

  • A-n--

L r k a 4 a4---V E .o f j s A. -A = A+ - h# n 1 L 0 h k 4 j L ( i I a f a 1 t 2 8 r F i l' Y. I Ln I i

=

{ i r P f w3 .Z. p 2 6 WC C i 3 3 L L-t 1 3 N O Z Z + W a I i . 2 T A W ' Gl1 Z b O I W l e

o. u N. T. e. ~. @. C. M. e.. e. O. M... M. @. M. n. N, T. M. N. N. o. e. N. N. M... N.

. N. N - N. N. . N. M. @. M e. e. N. T. O. @. T. c N -d = 0

  • M M M N - N N M N N
  • O O = = = = = = a a O O O O O O O O O O O O O O O = = = * = = === 0 O i

NW i a e e t 4 i I I I I i 8 I I e a e i I i 1 I I i t e + i 6 l 0 00 i O 3 T l e O r N e i Od N. o. M. M. N. a. N. N. T. O. @. @. @. . @. @. @. C. a @ @ @ = N. @. C. T. h. e. N. =. N o.. N. N. e. @. N N. d. a T. @. *. N. @. M. @. W =W E S OO NON@Ne@@NNO@m@*@@@NNeee@@TeTC=C4MNO@tDeTNTTNNO@c@@ W - *e 3-N N e Q * * - O C N O N - T CD O O O O O @ @ @ @ e N @ CD @ @ O = 4 e M N N N M M T M M M T M M M M N enname enemomeNNNNNe* *ewmeemenNNnnnnnnnnnnnnnnnn ( i h N.- z W N Og @ N. e. @. *. N. =. e. T. M. T. N. N. T. @. M. M. N. M. e. @. @. O. N. @. M. M. N. ID. N. N. =. N. @. N. @. CD. a T. e. O. T..= * * @ @ I M E q q s W N HE N N =.= M N T M T T @ @ T @ e N M M M M @ T @ * @ C @ =. M N 9 @ @ M @ @ T @ @ N N @ @ N N @ @ @ T I y y meon mee eee= W. i l G @ C *. N M T

  • N M T @ @ h e @ O.'a N M T @ @ N e @ O = N M T = N M T @ @ N e @ O, =.= N M T @ @ N e WW

e t = NNNNN e====**=*=NNNNN 3 i ' f it f -e-.. --o,.,,, ,,,.,,,,.,n, .mm..m... ,,--m-, ....-.,-,mv.,mm,,,._._s,. -r__-_m,--

1 l i 19 4.4 333.9 -0.1 j 20 2.6 297.6 1.2 21 2.0 290.0 2.1 J' 22 1.9 291.0 2.9 23 1.9 295.6 3.0 24 1.8 222.5 4.1 4 t 2.2 139.2 5.2 2 2.1 310.7 5.4 l 3 2.0 269.8 5.3 4 2.3 325.5 2.6 5 s.8 299.0 2.0 6 2.2 300.3 1.9 j 7 2.2 313.9 0.7 i l 8 3.4 322.0 -0.9 l STOP TIME AUG 31.1987 HOUR 7 MINUTE 49 i I i f l l l l 4 VI-55

y v e I RELEASE NUMSER. 87061 CONTAINMENT PURGE STARTING TIME SEPT 3.1987 HOUR 16 MINUTE.20 T rase WS10 WO10 OT110 HOUR MPH OEG DEG C . [. 16 15.0 145.1 -1.6 17 13.7 144.0 -1.3 18 13.2 142.9 -0.8 19 11.4 142.2 -0.5 20 10.7 140.6 -0.2 21 11.4 142.1 -0.3 i 22 10.6 142.0 -0.2 23 9.9 139.5

0. 3 '

6 24 11.0 147.1 -0 t 1 10.6 150.6 -0.2 2 10.5 157.0 -0.1 3 10.6 154.1 -0.1 4 6.8 147.4 0.9 5 8.4 154.5 0.3 6 9.0 157.6 0.5 7 11.2 164.3 -0.1 8 12.4 164.3 -0.6 9 13.8 177.4 -0.9 10 12.9 179.1 -1.4 11 12.4 175 6 -1.3 12 13.5 180.7 -1.4 13 11.9 167.5 -1.4 14 13.4 173.7 ~1.4 15 32.6 170.7 -1.4 16 11.6 169.0 -1.4 17 10.4 160.1 -1.2 18 7.9 152.9 -0.7 19 7.0 151.7 0.8 20 8.0 152.4 1.7 21 8.1 148.0 1.3 22 10.6 160.9 0.I 23 12.2 167.5 0.2 24 11.4 165.9 0.2 1 11.0 166.8 0.1 2 9.3 165.2 0.1 3 7.5 178.1 0.1 4 7.1 177.2 0.5 5 6.2 201.1 0.2 6 4.8 184.4 1.2 7 7.1 166.6 1.2 8 10.8 189.5 0.3 9 9.6 191.8 -0.4 10 9.4 195.1 -0.6 11 11.0 196.6 -1.2 12 8.9 222.8 -1.3 13 8.9 219.5 -1.5 14 8.0 226.1 -1.5 15 5.4 249.5 -1.2 16 3.5 313.9 -1.4 VI C (3 %Y 1 17 4.3 252.5 -0.9 18 3.3 194.0 -0.3 19 3.8 187.9 0.9 20 4.3 164.1 1.1 21 5.0 133.2 0.3 22 3.5 137.4 0.7 23 5.9 173.7 1.2 24 4.9 188.4 1.4 4 1 8.9 206.2 8.6 2 10.1 213.2 1.8 3 9.4 215.9 1.5 4 5.2 257.0 0.6 5 3.0 219.3 0.2 6 6.9 206.3 2.0 7 3.6 329.9 0.7 8 4.7 137.5 -0.4 9 3.3 229.7 -l.2 10 5.1 234.9 -1.3 11 5.9 230.0 -1.4 12 7.9 222.0 -1.5 13 7.9 218.9 -1.6 14 7.1 213.8 -1.4 15 8.4 202.0 -1.4 16 6.1 266.3 -0.6 { 17 10.8 207.2 2.6 18 6.0 109.6 2.1 19 4.0 135.5 2.3 20 5.0 113.1 1.2 i 21 8.6 153.4 2.0 22 5.I 145.5 1.4 23 3.5 244.8 1.7 24 7.8 2GJ.2 3.0 1 5.4 158.1 1.5 2 5.0 118.3 0.5 3 4.9 126.6 1.5 I 4 3.2 184.2 2.1 5 3.9 120.1 2.7 6 2.4 121.2 3.0 7 1.8 105.6 1.5 I O 2.0 224.3 0.2 STOP TIME SEPT 7.1987 HOUR 1 MINUTE 20 i 1 I VI-57

N,.. \\w-) RELEASE NUM8ER 87062 CONTAINMENT PURGE STARTING TIME SEPT 10.1987 HOUR 18 MINUTE 31 TIME wS10 WD10 0T:10 HOUR MPH OLG DEG C 18 4.7 188.4 -0.7 19 6.1 212.8 0.4 20 6.0 228.3 2.3 21 3.0 257.5 1.7 STOP TIME SEPI 10.1987 HOUR 20 MINUTE 57 1 l l STARTING TIME SEPT 11.1987 HOUR 12 MINUTE 12 i TIME WS10 WO10 OT110 HOUR MPH DEG DEG C 12 4.2 162.2 -1.3 13 3.6 78,2 -I.3 34 4.0 213.2 -1.1 15 6.5 208.8 -0.7 16 5.8 192.3 -0.7 17 6.9 193.7 -0.4 18 6.3 225.0 -0.5 19 6.0 245.1 0.1 20 4.2 273.8 0.6 21 2.0 6.2 1.7 22 2.7 356.3 1.2 23 3.7 304.2 0.6 24 3.1 318.4 0.6 1 3.3 278.6 0.3 2 3.3 318.0 0.2 3 3.8 316.t -0.1 4 3.5 320.2 0.3 5 4.4 333.4 0.4 6 3.4 319.2 1.0 7 2.2 292.1 0.2 8 3.6 331.8 -0.5 9 3.8 344.3 -1.0 10 3.6 298.4 -1.2 11 4.3 350.6 -1.2 12 3.5 271.2 -1.3 13 5.4 216.4 -1.4 14 4.9 214.0 -1.3 15 4.9 228.9 -1.5 16 7.0 194.3 -1.2 17 8.2 176.3 -I.2 18 7.0 165.4 -0.8 19 5.8 162.0 0.7 20 6.7 156.9 2.0 21 7.1 152.9 2.0 22 9.7 160.5 0.9 VI-58

~ A .V l I I l l \\ l m i I w> l C 1 W 3Z = I G 30Z N N. a

  • M. M. a @ @ M. O M T. @. N. e. N. @. @. M. T. @. @. N. O. O. c. e. @. @. T. 4. N. T. T. M. M.

e

          • =~~ONMMNC000000000*"

C00000000""1 5 1 8 I I I I I l I i 4 1 1 T e N L W

e. M. M. c. o. @. @. @. C. h. e @ @ a c. @. c. o. @ c. c. T. C. M. N. C. O. N. @. N e. =. M. O. M. @.

@TmNa@M@hNNMOO@e@a -=@N@NNN@@M@Mce@@@ @@@@O-NMNNT= ten @@@~ON@N==NMNNNMMNMMM m e onm ememenem omen ee eeNNNNMMn W 3 m N N. M. T. N. O. T. N. M. @. O. O. O. *. @. M. N. C. T. @. C. @ @. N. @. C. @. e e. N. W. N. @. c. @. N. e. a O c@NTMMM@NT@Tc@@@@@@M--NMT@NTT@N@@eNN me e ome me MT*NMT4@Ne@c=NMT@@he@O*NMT=NMT@@Ne@Q e NN eeeeeeeee eNNNNN

< -. 9 j ~ l- ~'yg } j RELEASE NUMSER 87063 CONTAINMENT PURGE l l STA2 TING TIME SEPT 18.1987 HOUR 13 MINUTE 14-j TIME WSIO WDt0 DT110 l HOUR MPH OEG OEG C } 13 5.8 309.1 -2.0 5 14 7.1 295.6 -2.0 l 15 5.f 299.6 -1.7 f 16 5.0 309.8 -l.5 17 4.7 283.9 -1.3 7 18 2.9 335.5 -0.6 ' t '19 1.9 321.1 1.5 20 1.9 258.9 1.6 21 1.9 280.7 2.6 22 2.3 316.0 3.5 [ l 23 2.5 302.6 3.6 j i 24 2.1 257.4 2.7 1 3.4 223.5 2.8 f[ 2 4.0 257.5 2.6 L 3 5.1 256.5 5.3 4 3.5 283.6 3.1 5 5.0 270.6 1.5 i h 6 4.5 285.8 1.4 7 6.3 270.1 l.0. 8 5.8 285.8 -0.2 9 6.2 295.7 -1.2 10 9.4 310.4 -1.7 it 10.4 322.5 -l.8 l 12 9.5 320.4 -1.5 13 8.9 319.5 -1.4 14 9.1 326.2 -I.4 15 10.2 330.8 -1.7 16 7.6 322.1 -1.5 i en 4.8 304.0 -1.5 } 18 3.2 295.0 -0.6 1 19 2.0 320.7 1.2 I 20 2.7 331.8 1.3 1 21 2.0 278.5 1.2 22 2.6 326.8 1.1 j 23 2.4 387.5 0.8 1 24 2.1 316.0 2.3 1 2.3 311.4 1.8 2 2.3 317.1 2.0 r 3 2.4 327.5 1.4 -[ 4 2.6 315.7 8.4 5 2.9 336.9 1.3 6 3.1 319.4 0.6 4 7 3.2 329,0 0.4 8 4.7 324.0 -0.9 9 7.8 331.2 -1.3 10 10.4 335.0 -1.4 It 10.2 327.6 -1.5 12 8.5 327.8 -1.5 13 8.* 329.8 -1.6 VI-60 t n '~h9*+1NWi.'D-WN+ttl'ewW atwr-'. u9 o'vWWWr.*.Tr-*+v' w w1 e e t-ws-wwtre--+*.- e- -e

  • W C't-*e

- M' e v= 1d ef-e g-w-w a-9m.----g WNa--wy_-e--><.govWe-.7'+rTTPn**S .-WN R W TTC"M":Pt- -m .T-'77"m

be Ny 14 8.2 323.0 -1.7 15 8.9 326.8 -1.5 16 8.8 326.2 -1.6 17 7.7 334.0 -1.3 18 5.4 329.9 -0.8 49 3.4 324.5 0.2 20 2.8 314.1 0.6 21 2.7 310.5 1.0 22 2.8 305.8 0.7 23 2.2 299.0 1.6 24 2.8 301.2 1.4 1 2.9 295.5 1.5 2 2.8 300.8 0.4 3 2.4 305.9 0.6 4 2.1 295.1 0.7 5 3.9 319.5 0.5 6 3.8 320.0 0.2 7 3.4 322.2 0.1 8 3.0 316.4 0.3 9 4.9 325.0 -1.0 10 6.8 334.4 -1.3 11 6.9 348.2 -1.4 12 8.3 338.2 -1.5 13 8.1 339.1 -1.4 14 6.6 337.4 -1.0 15 5.6 340.0 -1.0 16 4.4 345.2 -0.9 17 5.1 331.7 -0.5 18 4.2 335.1 -0.6 19 3.2 338.2 -0.2 1 20 3.1 311.2 0.7 21 2.7 292.1 1.6 l 22 1.9 293.1 1.9 23 2.1 292.1 2.5 24 2.5 284.7 2.6 1 1.9 288.5 3.0 2 1.9 284.0 1.8 3 1.8 281.1 1.4 4 1.9 305.1 1.7 5 1.8 292.9 1.6 6 2.0 281.7 1.8 7 1.9 309.9 1.6 8 1.8 319.6 1.2 STOP TIME SEPT 22.1987 HO?JR 7 MINUTE 12 VI-61

p ( l \\ o t' Y .Y RELEASE NUMBER 87064 CONTAINMENT PURGE STARTING TIME SEPT 24,1987 HOUR 14 MINUTE 2 TIME WSIO WO10 DT110 HOUR MPH DEG DEG C 14 5.0 78.9 -l.5 15 5.2 80.3 -1.4 16 6.1 91.4 -1.5 17 6.1 85.7 -1.3 18 5.2 73.1 -0.9 19 3.1 339.7 -0.3 20 1.5 180.9 2.6 21 1.5 200.9 3.1 22 1.6 266.9 3.2 23 1.5 193.3 2.3 24 -99.0 -99.0 3.5 t 1.6 272.7 3.5 2 1.5 272.8 4.3 3 1.7 306.3 3.9 4 1.8 296.4 3.6 5 1.4 280.1 2.8 6 1.5 281.3 3.0 7 1.8 192.3 3.2 8 t.8 296.2 3.1 9 3.3 14.4 1.2 STOP TIME SEPT 25.1987 HOUR 8 MINUTE 18 STARTING TIME SEPT 25,1987 HOUR 9 MINUTE 6 TIME WSIO WDIO DT110 HOUR MPH DEG DEG C 9 3.3 14.4 1.2 to 8.9 126.0 -l.1 11 8.8 124.6 -1.4 12 10.7 135.8 -1.3 93 11.8 187.4 -1.5 14 10.8 142.3 -1.5 15 10.6 151.2 -1.5 16 10.5 145.6 -1.6 17 9.4 160.0 -1.3 18 9.4 161.5 -1.0 19 6.1 158.2 -0.4 20 5.2 150.2 1.9 21 S.9 148.5 2.9 22 8.3 150.2 1.9 23 9.2 155.8 1.0 24 9.4 158.5 0.6 t 9,* 156.1 0.5 2 8.0 145.8 0.9 3 7.3 149.7 1.2 VI-62

/,v /- 36 s I V .800246661 96767 5894021 42456531 24431 8 1 3445533701 5454431 54 200000 1 1 1 1 1 0t 0000000000000001 1 1 l 1 1 1 3 1 0001 001 1 1 1 1 1 1 1 l 1 1 1 .030476236490 392641239845473091. 956561 976895570041 497741 1 309309197035431 81 4948 3C22848338356368 908. 51 679161 08 78460 42991 031566676767667888885666678877788976561 1 171 991 9902 22332232232233 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5 1 1 1 1 1 1 1 1 1 1 1 1 1 8807381 9 3 0 0 8.O 5 1 998 77950339.F547620241. 3 6 8 9 9 6 9 7 3 0 4 3 9 9.'/ 6 8 9 3 1 078001 .223328900357677764086743222321 32I 643254548009t 1 2 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 45678901 2345678901 234t 2345678901 2345678901 2341 234567890 22222 1 1 1 1 1 1 1 1 1 1 22222 1 1 1 1 1 I 1 1 2 1 1 i l 4! l' jli

r 1 11 3.6 316.4 -l.2 12 4.3 306.4 -1.2 13 5.3 275.5 -1.5 14 5.7 292.8 -1.8 15 5.8 277.9 -1.7 16 5.6 290.4 -1.8 47 6.4 298.7 -1.5 18 7.0 309.6 -1.1 19 6.2 323.4 -0.5 1 20 2.4 325.2 1.3 1 2 2.2 328.5 2.1 0 22 2.4 327.5 1.6 l 23 2.1 337.7 1.8 24 2.5 320.6 1.1 1 5.1 321.6 0.4 l 2 6.2 326.3 -0.1 3 4.4 320.3 -0.2 4 4.2 3 8.2 0.1 5 4.2 308.7 0.2 l 6 5.3 305.0 -0.1 7 4.1 301.6 0.3 8 4.6 301.0 0.1 9 6.2 309.9 -0.7 STOP TIME SEPT 29.1987 HOUR 8 MINUTE 15 r 6 l l l l l l l i l i t VI-64

5 6 I V O E T U N I M EG 8 R 1 UP P U T O N H E 4 TN I A 7 T 8 N 9 O 1 2834355539 t 0C 6381 46778753368825456673461 202629355561. C G 0001 0000000000001 01 234455666776301 1 1 1 1 1 1 0 1 1 1 1 1 1 1 l l 1 TE T OD 5 C 6 O 0 7 0G 70399987209761 2 9.P.?.2 8 4 8 8 6 3 8 5 3 9 7 6 9 1.3 6 5.I .51. 22623 51 801 8 . 439799 235569037860 E 1 E 3454903329505282029551 2908591 1 2680223998987777 R M OD 00023344333333344344443549695781 221 1 1 ? 1 1 1 1 1 1 1 1 1 1 1 1 W 1 E I 3333333333333333333333333322221 B T MU G N N I 220857 O1 8. O 1 0991361. E T 23392,9634539484091.. .0 1 S R 0H 4768231 / 5891 00281 2223222 A A 1 P 1389099977421 01 1 I 1 1 1 E T 5M 743423221 07391 1 1 1 1 1 1 1 5 1 L S W 1 1 1 1 1 1 E R ER a9012345 2345678901 2345678901 234I 234567890t 2345678 1 f 1 1 1 1 1 1 1 22222 1 1 1 1 1 1 1 1 1 1 MU l 1 22222 IO TH

.OJ 19 8.7 170.1 -0.6 20 6.0 154.2 0.4 21 5.9 153.3 0.8 22 6.9 152.5 p.7 23 8.1 167.7 0.4 24 12.1 174.6 0.6 1 13.0 175.8 0.3 2 15.3 190.2 0.1 3 13.4 181.2 -0.1 4 7.6 159.8 -0.4 5 5.8 146.1 -0.1 6 5.3 130.9 -0.1 f,. 0 135.2 -0.2 8 5.3 145.0 0.7 9 '.8 169.7 -0.7 to 7, b l98.1 -1.1 13 10.2 188.7 -1.2 4; 9.3 179.3 -I.4 11 9.9 198.1 l.5 8 - 10.*i 187.7 -1.5 e5 9.6 193.6 8.6 16 10.4 180.7 -1.4 17 9.0 186.0 -l.2 88 6.2 187.8 -0.8 49 2.8 150.94 0.5 ?:1 8.7 174.0 3.9 3.2 s27.8 16.0 22 2.3 323.0 6.2 's 2.5 5.1 3.6 24 3.4 15.4 2.3 1 5.9 315.9 2.4 2 2.8 291.3 4.8 3 3.8 357.5 2.3 4 8.9 327.8 -0.1 5 18.2 330.9 -0.4 6 12.6 328.5 -0.4 7 7.6 324.5 0.5 8 5.7 343.0 0.4 STOP T If 4E OCT 5.1987 HOUR 7 MINdTE 50 VI-66

w) []! i -sv RELEASE NUMBER 87066 cot;T A INME N T PURGE STARTING TIME OCT 8.1987 HOUR 87 MINUTE 44 TIME w510 wDIO 0T110 HOUR MPH OEG DEG C 17 12.3 207.4 -1.3 18 8.9 212.9 -0.8 19 5.5 205.5 0.1 20 5.9 218.0 2.0 21 5.1 320.7 2.s 22 6.0 318.9 1.1 23 4.2 3t7.2 8.7 24 4.0 320.7 1.6 1 3.8 320.2 1.7 2 3.s 339.s 2.0 3 3.1 310.0 2.2 4 1.8 298.4 2.2 5 1.6 320.4 1.2 6 1.6 322.0 0.9 7 1.1 314.5 0.8 8 1.0 324.3 0.6 I 9 1.3 326.7 -0.5 10 1.4 334.0 -0.8 31 3.0 346.5 -1.s 12 5.7 337.8 -1.1 13 1.3 345.3 -0.8 14 5.2 335.2 -1.0 15 7.5 338.2 -1.0 16 5.7 345.8 -1.0 17 1.1 345.2 -0.9 18 1.0 342.1 -0.8 19 0.9 342.7 -0.9 20 1.1 342.8 -0.7 21 1.2 330.9 -0.7 22 1.s 333.7 -0.5 23 1.1 329.5 -0.6 24 f. 332.5 -0.7 1 1.0 324.6 -0.4 2 1.1 331.9 -0.6 3 3.0 335.4 -0.5 4 1.0 336.4 -0.5 5 1.0 346.3 -0.5 6 1.1 353.4 -0.5 7 1.0 351.2 -0.8 8 t.O 343.1 -0.8 9 0.9 350.0 -0.9 10 t.: 347.8 -1.3 13 1.0 345.4 -1.0 s2 4.8 342.9 -1.2 13 1.1 334.7 -l.1 14 1.2 337.7 -l.0 15 1.2 339.3 -l.2 16 1.4 339.7 -1,3 17 5.0 347.5 -I.3 VI-67

~. -. I 6 9 9 j h i i 18 4.6 352.2 -0.1 19 1.2 334.9 -0.4 20 0.8 285.5 1.4 21 0.8 290.8 2.2 22 0.9 299.0 2.4 23 0.9 8.5 3.3 ') 24 1.0 329.9 4.4 i i 1.2 206.7 5.3 ) 2 1.0 324.4 5.6 '[ i 3 1.0 138.3 4.8 4 0.9 113.2 4.4 5 1.0 192.4 4.6 6 0.9 355.5 4.8 7 1.0 92.4 4.6 f STOP TIME GCT 11.1987 HOUR 6 Mit4UT E 46 STARTING TIME OCT 12.1987 HOUR 1 MINUTE 5 TIME wSIO WO10 DT110 HOUR MPH DEG DEG C } t 2.8 213.5 3.8 i 2 2.0 214.9 4.1 l 3 1.3 228.7 3.6 4 8.8 308.6 0.7 i 5 0.9 149.7 0.5 6 0.9 137.6 2.0 7 1.0 281.3 3.6 8 0.8 128.6 4.2 i STOP TIME OCT 12.1987 HOUR 7 MINUTE 44 i a 0 e i i t s l 1 j VI-68 i

~_ -.x / \\ f f i %I L I I O f W j \\ l [ I No 1 e I l W 4, 3 i .Z. i l 3 WO 2 3 lb 3U T 9 g z se 3 .E. 1 ( N t s N e .i t O - U OO

e. @.@.@.T.@.T.@.N.@. @.@.N @ @ @ @ @ Q e.N.@.@.@.Q.N.@.M.M.@.N.*.*.N. M.T.e.@. e.@.@.M.@.= N.=.N M.=.

i-

0 0CCCOOOOQOOMQQQOOC-OOOOOaOOOOOOOOOOOOCCO=0Q=====

NW s e a e i e e i e a a i s e a a e e a e i 6 e e i e a e e e i e i e a e i e ( >- QQ } N U O I O l ~c CO G.O.N O.M. e.M.O.N. ' 7. @. e. N. a N. e.. 0..=. T. N = T. ~. @. @. e. N. N. @. C. e. =. T. N N. N. O. M. e. @. @. e. M. M. e. @. *=. w W 2 3 OO T M *= a e @ @ N to to N $ N O = 50 - @ - @ # @ @ N N 9 N N @ O 9 O N T T C 9 N M N O N = 00 @ @ @ N N W

== R O e @ N M 4 @ @ - Ch W e @ O M N N N M = = N O = = = = 0 0 O O = N @ 12 @ @ O to N T T @ M = cp @ e e C p. N = = = a==== = N - N = N M M M M M M M M M M M M M M M M M M M N N N N N M N N M N - N N = *==

  • 3 s O Z

.Z. W N f a Or @ @ - T. e. @. N. c. e. s. M e N @ N. @. @. T. N. M. M... @. N. e. e. @. @. e.. T. N. C. @. e. @. N.. O. T. N. N. @. T. @. m @ N. q -i W N @3 T M T T M 4 @ @ @ fi N N N a fl M N T T @ @ @ T M @ @ @ T T M N N N @ @ T M M T T M *= M @ N $ = M M .J R

  • = = =

W E i @ N e. @ O ** N M T = N M T @ @ N e @ O = N M T @ @ N e @ O a N M T

  • N M T 4 @ N e @ O
  • N M. T @ @

i WW R3

e. e e eNNNNN e eem ee ee eNNNNN e e oe me N

e ,y.._,---- ,_,,-_7-,_y,_,.,_-_.y,_,_-ny_, - _ _ -.,. ---,_.- e- ,_._,n---,

e 17 13.8 183.3 -1.0 I8 12.6 185.5 -0.8 19 8.4 163.7 -0.2 20 9.9 165.1 0.4 28 9.9 163.6 0.5 22 11.9 180.4 0.8 23 13.8 186.5 0.7 24 11.5 218.2 0.7 1 3.5 176.1 0.4 2 5.3 131.1 2.5 3 1.5 253.3 5.2 4 1.0 305.9 4.0 5 1.5 312.6 3.4 6 1.0 320.9 0.1 7 1.0 332.1 0.1 8 0.9 303.7 1.1 9 1.4 295.6 1.3 to 2.4 303.1 -0.3 3 11

5. 8 8.2

-1.4 12 6.7 29.8 -1.5 13 7.4 17.1 -1.5 14 8.0 11.4 -1.6 15 6.8 16.9 -1.5 16 7.3 15.8 -1.6 17 7.2 5.3 -1.2 18 7.3 2.8 -0.7 19 5.5 2.3 -0.5 20 7.3 347.6 -0.7 21 4.8 348.5 -0.3 22 2.5 306.1 0.5 23 1.0 303.4 1.5 24 0.9 297.9 1.6 1 0.9 298.5 1.3 2 0.8 283.5 1.4 3 0.8 295.9 2.5 4 0.8 304.3 2.8 5 0.9 289.6 1.5 6 1.0 281.1 1.2 7 0.8 287.9 1.1 8 0.9 290.3 0.7 STOP TIME OCT 19.1987 Hourc 7 MINUTE 40 4 VI-70 1 i ? m

RELEASE NUMBER 87068 CONTAINMENT PURGE STARTING TIME OCT 22.1987 HOUR 17 MINUTE 50 TIME W510 WD10 DT110 NOUR NPH DEG DEG C 17 8.7 318.7 -1.4 18 6.6 318.9 -1.0 19 3.2 302.2 0.5 20 2.2 312.3 1.7 21 2.3 298.1 2.0 22 2.1 296.8 2.4 23 2.1 296.4 3.0 24 1.7 36.6 2.0 1 1.6 155.1 2.7 STOA TIME OCT 23.1987 HOUR 0 MINUTE 15 STARTING TIME OCT 23.1987 HOUR 15 MINUTE 20 TIME W510 WO10 0T180 HOUR MPH DEG DEG C 15 5.0 321.5 -1.7 16 18.8 88.9 -1.3 17 5.7 123.2 -1.1 18 1.9 69.8 -0.6 i 19 1.0 29.8 -0.5 20 0.9 256.9 0.3 STOP TIME OCT 23.1987 HOUR 19 MINUTE 41 i l l I VI-71

.mm.... _ ~. .~........ s. .m 3 I J r t 4 a s ] ~ j - i 4 AELE45E MUdSER 87068 CONTAINMENT PUAGE 1 i ST4RTING TIME 'OCT 24.1987 HOUR 7 MINUTE 32 3 4 j TI3E M510 M010 DT110 1 HOUR WPH DEG DEG C s I l 7 5.1 320.0 -0.3 i 8 6.2 331.0 -0.5 4 9 7.7 343.4 -0.3 r 10 9.5 348.9 -l.2 i i 11 9.2 353 2 -1.6 i. 't 12 8.4 352.9 -1.4 -{ 13 6.0 353.0 -1.5 j

i. 3 14 5.9 10.1

-1.7 15 6.0 359.7 -1.6 l 16 4.4 15.7 -1.6 1 17 4.2 23.3 -1.3 l 18 3.6 43.7 -l.2 19 1.7 15.0 0.1 l 20 1.0 223.4 2.1 l 21 1.2 202.6 2.5 I 22 2.2 122.4 3.4 i l STOP TIME OCT 24.1987 HOUR 21 MINUTE 10 'l I i I STARTING TIME OCT 25.1987 HOUR 2 MINUTE O l 1 e 1 TIME WSIO WD10 DTit0 '[ HOUR MPH OEG DEG C j 2 3.6 184.0 2.5 i 3 2.3 120.1 2.9 f 4 5.1 112.) 2.0 l 5 6.3 125.6 1.4 6 5.7 121.4 1.3 l f 7 6.7 124.4 1.0 i 8 7.7 129.9 -0.3 9 30.1 141.2 -0.8 f 10 12.4 158.6 -l.0 ' 7 l 11 12.3 161.5 -1.1 I 12 52.0 149.8 -1.1 13 11.1 147.3 -1.0 14 10.3 138.4 -1.0 15 11.1 129.7 -0.7 16 11.7 113.9 -0.5 i 17 10.8 184.3 -0.7 18 9.5 119.7 -0.6 19 8.4 135.6 -0.6 20 8.6 134.3 -0.7 21 8.1 138.8 -0.3 22 6.7 140.3 -0.5 23 5.9 139.4 -0.5 24 1.5 133.7 -0.3 .VI-72 . l t-t' .--w- -e -,e n -.~.,-.,en-n, ,~~~v--. .,, - -, -. - -, -, - - -,, - - ~ ~ ~ ~ - - -,-,, e -w . - - ~ - -, ~,.---,-..m-- -~ --. + - - - n.--- L----

w M N I m> M W 3 .Z 3 l G 3 OI N T. @.T. M. N. @. M. T. *. @. (D 0000000000 4 i e t t e a e e s N >= V

  • N @.@.N @ @ N.@.@.

O CT@NM@@evM l M @ 4lD O 4 O @

  • 1 O

~**NNMNMNM l W I 2 m W O.@.@.@.N M N @ N.a. O CL @@NNN***M@

  • NMT@@NO@O e

.______.__...._..m.... .. 7 G l i i i RELEASE NUMDc9 87069 CONTAINMENT PURGE L I i + i STARTING TIME OCT 29,1987 HOUR 13 MINUTE 15 t TIME WSIO WDID OTit0 l 9100R MPt 4 DEG DEG C t ) 13 -99,0 279.9 -6.1 a 14 4.6 171.2 -2.0 1 15 5.3 169.2 -1.7 h I STOP TIME OCT 29,1987 HOUR 14 MINUTE O s i b j i L l i f i t i i i i I i i i L 4 L r i k I I l'l t I VI-74 5 f t l ~ -.

/" .( ~ RELEASE NUM8ER 87070 CONTAINMENT PURGE STARTING TIME OCT 29.1987 HOUR 20 MINUTE O TIME WSIO W0to OYtt0 HOUR nPH OEG OEG C 20 1.8 264.3 5.1 21 2.1 86.9 4.8 22 3.3 136.9 4.5 23 7.3 192.2 3.3 24 6.8 228.1 4.2 1 3.4 220.0 3.2 2 3.1 78.3 3.3 3 4.4 120.4 3.3 4 4.7 19.2 4 i 5 4.0 208.9 's. 3 6 1.5 359.7 4.1 7 1.6 297.6 4.6 8 1.1 291.5 5.1 9 2.3 326." 1.7 10 2.9 329.1 -1.4 18 2.7 359.4 -0.7 12 4.5 35.5 -2.1 13 5.6 50.7 -2.1 14 4.5 60.8 -2.1 15 6.0 77.6 -2.0 16 5.2 338.2 -1.8 17 3.6 63.0 -0.6 18 1.0 334.1 1.7 19 1.1 345.5 1.6 20 1.3 288.3 2.2 29 1.9 281.5 2.0 22 1.5 283.6 2.5 23 1.5 289.5 2.2 24 1.4 278.5 0.9 1 3.5 211.0 0.7 2 2.5 55.8 -0.1 l 3 1.7 351.6 0.7 .I 4 1.2 290.6 1.4 l 5 8.2 298.7 1.2 6 8.6 33.4 0.2 7 2.8 100.1 -0.4 8 3.9 85.7 -0.5 9 4.3 349.6 0.9 10 4.6 97.5 -1.1 l 11 3.1 84.4 -1.2 [ 12 3.2 110.8 -i.4 13 2.2 141.6 -t.2 14 2.4 353.9 -0.7 15 2.5 45.7 -0.9 16 2.3 309.7 -1.0 17 f.8 22.1 -0.4 1 18 2.F 75.4 -0.5 19 4.3 356.8 -0.6 ,[ 20 3.0 8.9 -1.1 VI-75 ) s t +v,,. w. e.-*<...-.--.-..-~m. we..,-m .m. .m.m L - m- -,...m...u,..~..-m .... +-- -

{ O e j 21 2.6 342.2 -0.7 i 22 1.3 349.5 -0.5 23 1.2 210.5 -0.5 l 24 1.7 8.6 0.1 i l t 1.4 335.7 0.2 i 2 1.7 305.0 -0.5 6 I 3 5.3 297.0 -0.5 I 4 1., 6 301.0 -0.5 5 1.6 316.9 -0.5 i a 6 1.5 28.8 -0.6 i i 7 1.4 264.6 -0.5 l 8 2.E 125.9 -0.9 5 l 9 3.8 112.4 -0.8 L i 10 2.2 247.3 -1.0 t l 11 2.4 36.3 -1.1 5i l 12 1.9 94.8 -1.1 l l 13 1.5 299.3 -1.2 1 { 14 1.7 15.4 -1.4 [ 'S 5.5 197.2 -1.7 l 16 2.5 72.5 -l.5 17 1.9 85.0 -1.6 y i8 i.4 247.0 -1.t 19 3.1 189.0 -0.5 20 5.3 130.1 -0.7 { l 21 3.9 119.2 -0.4 22 2.7 117.3 -0.2 r { 23 2.5 114.7 0.4 [ 24 2.2 127.3 1.0 4 ) 1 4.7 127.1 0.7 2 5.4 146.7 0.2 ] 3 6.8 146.4 1.0 4 8.6 149.5 J.5 5 8.0 147.6 -0.6 1 l l STOP TIMC NOV 2.1987 HOUR 4 MINUTE 23 L 1 I L ~ I i n l I t r f l f i VI-76 [ 4 t 4 t i i l t ..-~..- --- _.,_ _ _. ____..-_ _ _. _ /

f% t \\'\\,/ L h N I ? %J >g >= 0 T M W W O 3 3 2 2 W 3 2 W 3 J O 2 M = = a N 3 3 a 2 2 3 C 3

  • 9 9

2 .J 3 3 2 OI = T P-N C Z O

  • =

u N, a. N. W N M. cD. O. @. @. @. @. a = @ N. .. N. M. c. @. P= cD, N. e N Ou Cu T. S. O. N. T.co. c. e. N. O Q. Q. M. M. ad

===--o-00C00000000=*--*

.3 N N QCCCO*--*~ j NW s t i 6 i a i e t NW t i s i I 6 e i e a a e e a i e i et i 6 N > QQ QQ = 0 0 W Z Z O N O @ N.@.@.M.T. @.N.Q.*.C.O.M.O.O.T.T.N T.T.M.@.T.@.Q. 2 00 00 @ M. co. N. @. @. @ @. N. N. N @ Q N. W -w W -W CQ e - @ T M O S P= N - @ @ T @ @ @ @ M N M M T N N O 2 3 OQ N e @ N.- @ NNNTmT@ 3 .T @ @ T ID N. M M M T.=.==.. N m N m m m M M M M m m 3 QTMON-MMMMMT W

== 3 T M M M O @ N W @== @- @ @- @- @ e > . - = = - N --. -= - 3 W i 3 0 3 0 2 2 2 = W k. M. e. @. @. T. Q, N. c. @. M. @. N. @. T. M. P'. c. @. @. N. M. N. N. @ T A 2 OT 4..- T.@.T.N.O.T.T.@. T.@.@. M E OT Q T T T -K @3

  • M T @ N @ @ @ @ rs @ M M M a * = N T P= @ e N...

W 5 M3 N T T @ ID @ Q C CD = N M O N. .J 3 W 3 W f 3 f l M T @ @ N.= e.- @ C = N M T - N M T c @ h e @ o - N M l WK O*NMT*NMTO@Ne@ Wg - -. - = NNNNN = = = - - - 33 NNNNN 33 -o P9 P-r I l I i

______-_.__________.___...__.__...___..........m.. .m-__.. i 4 4

O i

i J 'n f' lt 1 ) I i i I t r ? 1 5 4 t l l l ll [ ( i I I l l i b F CO 5 N i m> I I I f I 'T I W t I .Z I 2 N I I 2 3 9 k A @ e. P. 9 9. @. N. M. T. N 9 9. N. *. a N. N. N. O. to m -a===00GOOOOOOOOOO-t t i i 4 e e 6 a i e i i O l >0 r =.N.N.N c.M.M.C.O.N M M.M @ @

  • 4.O.@.

Z h MMMMMMNNOCOc@mm-OmM y MMMMMMMMMMMNNNNMMNM W 2 N e.M.T. C.*. @.@.o.@.N.N.@. .=. 4. %. .@.M. o =0OeWTTTM44NMMMTMMt e--- a L .=

e.. h e- @ O = N M e - N M e o @ N e wc NnNNN f

U ? h f

m_. /~% f N i RELEASE NUMBER 87072 CONTAINMENT PURGE STARTING TIME NOV 12.'987 HOUR 20 MINUTE 38 TIME WSIO WO10 OT110 HOUR MPH OEG DEG C 20 1.7 219.1 3.1 21 1.6 231.4 3.8 22 1.6 292.3 3.7 23 2.0 16.0 6.4 24 1.6 76.3 7.9 1 1.5 120.2 6.8 2 1.3 182.3 4.0 3 1.3 166.8 4.9 4 1.1 241.9 5.0 } 5 1.2 140.5 6.7 6 1.4 358.8 5.4 7 1.3 276.9 5.4 8 1.0 159.0 4.7 9 1.2 164.7 5.0 10 1.0 198.2 1.8 11 2.7 351.3 -1.0 12 1.6 309.0 -1.5 13 1.8 328.2 -1.8 14 3, 2 353.0 -1.9 4 15 4.4 25.8 -1.8 l 16 4.2 18.9 -1.6 17 3.2 2.5 -1.4 is 1.2 288.3 -0.5 i 1 19 1.1 263.6 0.7 20 0.8 273.8 2.0 21 1.1 272.5 3.2 1 22 0.9 249.2 3.1 23 0.8 258.7 3.5 24 0.7 107.2 4.1 1 1 0.8 24.0 3.7 2 1.2 291.7 3.3 3 1.9 286.4 2.8 4 1.7 199.0 2.7 5 2.1 145.1 3.0 6 0.9 238.4 2.8 7 1.1 342.0 2.6 b 1.1 50.1 2.1 9 7.4 123.6 -0.4 10 9.4 129.1 -1.5 11 10.1 48.5 -1.8 12 12.8 128.5 -1.8 13 14.6 132.3 -1.8 14 15.2 131.3 -1.9 15 13.6 130.8 -1.6 16 13.8 145.2 -1.4 17 12.8 134.8 -1.3 18 15.2 132.9 -1.0 19 14.5 132.9 -1.0 20 16.3 136.3 -1.1 VI-79

\\ 8 m> N.o.... N.@.o.@.c.N.M N. @.@.@.T.G o o.k.o.m. k h @ T.e. @.N o N 4.c N T T.T.W.h.@.h. @ e > @ T T.M.M M.. @ e.. ...o.o...........o..cococo............... ...... 00 e e ee a e e i s 4 e s e t i e e 4 s e e e e e t i e i e e i e e e e e e e e s 4 1 i s t e s i e e s i M. o. m. m. e. M. C. e. M. @. e. @. T. @. N. J. @.. W N. N. S @. T. @. e. h. T. @. e. @. e. @. Q @. T. @. N.. @ Q. C. C. T. @. @. e. @. . N O. T. @. .h@h@Nho@hMMo@@h@M@@ . h e @ M O O O M @ @ h h m @ @ h C N N T C. M c, N N N T @ @ T @ @ @ @ h @ @ m @ O... = O N M e @ N @ h N. M .MMNNTM.O M M. 4 T T T M. M. M. N. N. M. M. T T T T M. N. N. @. @............ N N N N N M M M M M M M M M M M M M M M M.. @ M.@.c. @.M.N.N.T. 4.e.M.. @ @ @ @ @ . @ h N.O.T.T.e. @.@.T.M.h.h.*.e.@.T.e.o. @.o.. N. M.@. @.@.T.@.@.@.. @ @ T M. P.s. O... N. N. N. N. M M. T. @ O. c e @ @ @ M T @ 5 @ @ h @ @ @ e M @ T @ h h e @ N M b e c e @ N h @ @ @ . N M T. N M T @ @ h e @ o.. N. M. T @ @ N. e. @ N N N N N.o.NMT.NMT N e @ o.. N. M. T. @. @. b. s. e o. N M T. N M .NNNNN NNNN I

a..s. .smuw.mu_ om muu,aswa We e es my a m- --5-ume.m.e--&sp.J.e-oMe-AaumW-W am ae.B.==+ a 4J-e 6 am M a-.46-MMM,dR4-- "-D_11-' ---Nd4.haMmM 4M.m--AAw4hh4aeet6 mmAa-_m.__ h p 5 i,. I 4i 5 !e f - l f 1 I i t i 8 i l a i i i e i t i \\ l 1 l l l l i a i M co a I 8 1 N Y C* O i 1 2 g 8 a i e-I O l S I f Ptn S N. C. @. C. @. e a i

  • CC=O 4 a e 4 4 Pm I

h 1 e j 1 O i

  • r=. *. e. M.

2 4 l d 9MM@h I comee i nnNNN e W 4 .E N n N. h. h. # { o e wn - I W l l s $hYk& E f l i ) l 1 1 4-

f'N r 1 A r"s N O t e \\ m> e N W = 3Z = 2 Wd O a34 23 9

  • zw 32

= 4 N N e 2 O u

c. h @ M. N. N. e. =. @. @. h. @. @. O. O. e. T. N. @. e. O. M. M. e. =. S. e. @. @. *. =. m. M. @. N. N. e @ N. T. O. N e.

O QU N = ~ =C 000=O=000==**NN~*O00===Q=OOOO==C=~~~~~~==O00=0000 Nw t t 1 I e i l e i t e a a t I e i e i t 6 4 t i e a e a e i s t i > OQ M O N 2 O Ne

e. M. Q. =. O.. =. M. @. Q. T. W. M. S. T. N. @. =. O. =. c. T. @. e. @. @. N. a. @. N. T. O. N. N. =. @. M. N. a c. o. e. w. c. M.

C0 W =w E 3 00 =NeNNMT@@NNOce@eNM@@ Nome @@@N=@ONOceONMO@=McMTMNet W = 3 O@eOO=@@mm @MOa@@MN=NMNMMO@@@@@@@@@N@@@@@TT@@@@@@ C N MNNMMMNNNM N M

==N=================

33 0 3 2 = W N O. W. @. @. N. =. Q @. N e. @. @. h. *. O. =. e. N. T. @. O. e. @. @. @. *. e. M. O. T. @. M. T. N. M. @. M. N N. N. W e s QI 4 4 =1. W N @2 TMTMMN===N=NNMMMNNNM@T@@NNN= 1MMT@@NeNN@@NOTTTTTTT

============

"g e 3 N " N e T @ @ N e @ O = N e T @ @ N e @ O = N M T = N e T @ @ N e @ o = N. M T @ @ N e @ C = N, M T = W.

==========NNNNN

==m -======NNeNN 33 N

I 'l i i i 2 14.5 163.9 -0.7 { 3 9.4 152.7 -0.9 4 5.0 119.7 0.3 j 5 6.3 133.4 0.7 6 7.3 137.1 0.7 i 7 6.3 132.0 1.0 8 5.2 134.7 1.0 l 9 7.9 132.3 0.7 10 11.4 151.2 -1.9 l 11 13.6 168.6 -1.6 1 12 14.1 173.3 -1.7 l 13 11.2 878.2 -1.9 14 8.2 178.8 -1.8 15 6.8 179.7 -1.6 16 5.1 177.8 -1.4 17 3.1 168.6 -1.3 18 3.1 243.6 -0.9 19 6.6 303.7 -1.3 20 4.3 296.2 -0.6 21 4.2 295.0 -0.1 22 7.0 295.1 -0.7 23 6.8 299.2 -0.8 1 24 6.4 314.9 -0.8 1 5.1 295.I O.4 2 6.5 296.1 -0.6 3 4.9 288.3 -0.1 4 4.1 284.4 -0.2 5 3.0 274.3 -0.5 6 3.3 286.1 -0.2 7 5.0 284.5 0.1 8 4.9 278.3 0.2 STOP TIME NOV 23.1987 HOUR 7 MINUTE 21 ) I VI-83

I \\ RELEASE NUMBER 87074 CONTAINMENT PURGE STARTING TIME NOV 25,1987 HOUR 19 MINUTE 56 TIME w510 WDIO OTit0 ) 1 HOUR MPH DEG DEG C 1 I 19 3.5 8.5 -1.4 l 20 4.8 33.0 -1.5 21 5.9 48.5 -1.4 { 22 5.9 72.4 -1.5 23 5.8 85.7 -1.3 4 j 24 5.8 86.5 -1.4 j i 1.2 38.0 -1.5 2 2.6 40.9 -1.2 3 3.4 30.4 -1.4 4 3.2 37.3 -1.3 5 4.3 50.5 -1.4 i 6 4.6 65.3 -1.5 7 3.2 26.7 -1.4 8 2.7 20.6 -1.4 9 4.1 53.4 -1.3 I 10 5.6 50.7 -1.6 i l 11 6.2 58.4 -1.6 12 6.0 74.0 -1,6 13 5.8 74.3 -1.5 14 5.9 64.2 -l.6 15 5.3 55.1 -1.7 16 4.9 44.0 -1.4 17 5.3 43.9 -1.3 18 5.5 47.5 -1.3 19 5.3 55.8 -1.4 20 5.9 68.6 -1.5 21 5.2 56.0 -1.4 2 22 5.0 62.7 -1.4 23 4.0 18.2 -1.4 24 3.7 350.5 -1.4 5 4.6 357.4 -1.3 2 5.2 9.6 -1.2 3 3.7 0.7 -1.2 4 3.6 2.1 -1.2 5 3.5 29.7 -1.3 i 6 4.3 3.9 -1.3 7 4.4 0.2 -1.3 8 4.6 353.5 -1.4 i 9 4.4 352.4 -t.2 IO 5.4 4.3 -1.3 II 5.0 29.4 -1.3 12 2.4 359.7 -0.4 13 3.0 336.9 -0.8 14 4.7 347.4 -1.0 15 7.0 0.5 -1.2 16 7.2 7.7 -1.4 17 7.0 1.1 -1.1 i 18 6.2 1.2 -1.2 j 19 5.3 3.4 -1.1 VI-84

O-20 6.3 0.9 -1.1 21 6.2 352.5 -1.3 22 7.3 356.4 -1.2 23 7.7 4.9 -1.3 24 7.0 3S9.5 -1.4 8 5.1 346.4 -1.1 2 5.5 326.7 -1.1 3 5.4 326.4 -1.2 4 5.3 324.1 -1.2 5 6.0 328.8 -1.2 6 6.5 329.9 ~1.2 7 7.4 329.4 -1.4 6 6.9 327.0 -1.3 9 6.9 327.2 -1.3 10 7.2 328.7 -1.3 II 8.1 327.2 -1.2 12 9.9 328.3 -I.6 13 8.4 328.2 -1.6 14 9.2 329.8 -1.5 15 10.1 330.8 -1.3 16 9.9 326.1 -1.4 17 9.3 322.4 0.9 18 8.3 325.3 1.8 19 8.1 324.7 0.3 20 s t '. 8 320.5 2.0 21 12.4 323.8 2.0 22 19.5 323.7 2.3 23 10.4 324.3 1.8 24 10.6 324.4 5.8 t 9.6 324.7 -0.7 2 10.6 323.9 -1.1 3 10.7 323.5 -1.3 4 10.5 319.7 -0.9 5 9.2 324.8 -1.1 6 10.5 323.7 -1.0 7 8.4 324.3 -1.8 8 6.9 323.1 -1.2 9 7.0 322.9 -1.3 to 6.4 323.7 -1.4 11 6.7 322.0 -1.5 12 8.4 308.2 -1.4 13 9.2 312.1 -l.3 14 10.8 316.1 -l.5 15 11.5 319.6 -1.5 16 10.8 328.7 -1.4 17 7.3 320.5 -1.6 18 7.7 316.7 -1.6 19 10.5 320.5 -0.4 20 7.4 320.3 -1.3 21 6.9 319.3 -1.0 22 7.2 322.0 -1.0 23 7.3 318.5 -1.3 24 7.2 319.9 -1.3 1 7.3 321.4 -0.4 2 8.9 323.7 -1.4 VI-85

4 -.A& 4 e Am e a b 4 Mh M Ad h.m2M hJhm meh h h d we BAS Jhh 45-M M.M 4" ~ 4dMM2A&a.wh+s..A 4sw--- a g ar _R e MMAhmmzM M. Ap p a Ae m_ m a s E s. Sa A_mmy4.5amam_e 4 5 I 1 J f 1 S 6 s r i i P e i + f a 1 i 1 9 4 v f 4 M l I w i l 32 l l E 6 h l l 23 I @*@NSN e e e s e e.e = =. = a aie a I O l M I f o i z

e. M. e. e. k. o N=e@h=

i NMNNN= t")M M M M M inJ B I IL g v. @ h. *. M. o emeWN@ > 9 A I Me@ene

M'M / k ) s Ns N \\ 9 R> M W 3Z = 3 W d N 2 34 23 O 3Z m W h > c Z S O

  • T. @. @. e. T. S. C. O. T. M. @. e. T. M. O. N. T N, T @ h @ @ @ N. N. N C. M. T. W. M. @ *. @. h. h = = @ @ @ C. @. e. @. h k. T.

u M QU C00000===0C000000-000000 =0 0 0 0 0 0 0 @ @ = 0 0 0 0 0 0 * = = = = = = = = *4 kw 4 8 I l 4 l @@ l 4 4 4 t t t 4 i 0 5 0 t t t 4 i e i I e l l e l e e t t 6 4 V 00 i t w h o o h @ T. @. T. e. =. C. o. @. N. @. M. m. M. 4. =. Q. e. T. =. C. h e. s. *. =. N. O. M. T. M. e. t. m. m. e. m. e. N. e. *. @ e 00 w w @MTOTT@@CNTTMN44CN@=OSOS@*e@@@@MT@=@@COS=Oh@M@@TN 2 3 00 NON@@T*NT=NNhCN=N=hh@@NNNaQC==O=N=NNNMMNNNNNNM w = 3 -9 e > MM MMMg I MMMM

===Mwww.e=w=================cee

33 0 Z Z = O. E @ N. N. o. @.. =. O. C. O. N O. @. C. N. e. m. e. O. t. e. N @ M. *. e. @. @. *. N. o. @. =. T. =. O. =. N. T. N. @ W N T A e W > M3 @MTMM@@@@MTNNN=NT@@@@@@@MMM@@TMT4@@@@@@@CMTNC.O,Ne@ q = a 3 w 4 e i E '%w/ h e @ O = N M T = N M T @ @ k e @ C. = N M. T @ @ h P S O

  • N M T = N M T @ @ h e @ C. =. N. M. T. @. @. h.

Wa --NNNNN ,3 ---NNNNN

=_ i l I I \\ r e r I e I l-i 1. 1 4 I f w 32 I k i E') 9 t

l a

i m N. N. M. M. N T. @. o. o. e. h. @. e. h. m. o - S. M. M. 4. M. M. o. o = = o. a @ * @ @ @ @ N. S. N. o. e. e e--e ee--omocoo-o==O l ooooooooooooooo----em i e a a i t I a e e e : a a i a e e e e e i e e i e s 6 e e e e i e i a i e W j i i y w I M.N. @. e. M.o.@. @. o.M e. N @ e. N. c. @. N. e. N. @. M.N o.g .h M.N. 9.m.h @ @ = @ @ M. N. o ( @NN9hNhoe*T==T@@hNTM0oMMT@g9NoC@N=-W=-o-I vi =NNNNho--09@@c -@T@@@N ch*

  • -9ThNe@e-OMM

=N-- t ee--===ee N E i s i

o. w. o. c. e. M. m e. m.. M. ~. o. o. w N.

. e. n c. e. e. ~. N - < e m e. s. n. . M. M.. M. o.. o.. o N N N N ll0 h 4 T M N N - N N - - N N N N N N N N N - - = - = = N N - - N c N M M w t 1 (. I e@o-NMw-NMec@se@o-NMe.3@hemo-NMe-NMeo@ne@ i --NNNNN


NNNNN n

) b I i \\ i.-- ,-,n e.~-- - -,, - -.,.. -.., _ - - -

...,=., - - ~. -... a.. r A .f L t I \\ I i f h i t l ? 4 I I r I + i 1 f 7 I i h = e h 6 1 e9 i I w 3 r 2 = i 3~ t= e s a b f h f 3 Z D f -( h = m t 2 6 c = U

m. h. e. >. @. @. N. M. *. M. N. M. @. N. =. N. c. Q. 9. @. h. e. c. =. T. @.
  • e. =. =. M. c. M. M. @. h. @. @. @. e. c. t. @

r C QU s

=0 00000000000000000=======QO00000000COQCCO-===NN==O ) kw e 6 e e e a 6 a e a4 1 eeee6 e a a a a e t o t a e ae# a e e ee i t U QQ t c w [ h C O ? h e

9. t. h. e. M. =. O. c. t. e. O. M. W. O. @. =. e. M. e. M. O. s. m. C. @. e. e. =. O. M. M. 9. M. M. @. T. h. h. e @ = M. M. N. h. @. N. g e.

I0 0 o$ M@wowhome==eMN=e@Cuc=N@vhenceocameh-Me@emeMochaeo I sw = 3 WNhheNmCOeeemeehemeecesehhhh@heekemechheseOOOOOO= L

=====NNMMNNNNNNNNNNNMNNNNNNNNNNNNNNNNNNNNNMMMMMMM L I m f N h @ t e. t M. N. M. M. + @. C. e. =. c. e. b.

d. M. e. @. N. N. e. e. O. @. Q. N. M e. k. M.

. S. M. @. h. e. N. @. h. o. m. =. N. S. N. M. } e a O ( q = MMNMoss<MneecochMnmMMM-@@@nencodeeceen==NMMMN.O@ w e a a e 3

=

=

=

=

t w WE heeO=NM9-NMW@@ke@c=NM4W@hemO=NM9*NMT@@he@c=NMW@@h I 3

===NNNNN

==========NNNNN

==

l h I .----m.~. __..~.,,,,..,,m,,_ ______,_.,m. I-

l 4 b b n r a i i n i F 1 t O 5 O Ch i e I M k 1 N = us >) 4 .Z d I 4 { h 3 1 3 9 + .t J l A e 1, M.a @ @ v. @.,. M.e. @.M. M.M.T. @. e.v. e. C. e e.c.h. N. M. @ M. @. h C.N.e. @. @. M. @.N. C. 4 OOO*N==000CO=000==N==N=====00==0CO====* = ] e a e e i 6 e a e e 6 e e i e 6 a 6 i e e e i 1 e t i T i k 6 1 ll V w 1 N. M.N.e. @. T.M.M. N.N. @.@. h O. @. c.N.@.~. @. M.C.@.@. Q.N. @.N. O. @.M.T. T. @.N. N.M. M. C. Q f NN=Nhb4T@ho@e=== nth @@@S@ MMS==@NSN=hMN@N @@eeehhhhhh9M@@@@ONMMma =4MNNOeN=0=T@4MN NNNNNNNNNNNNNNNNNMMMMMMMMMMMMNMMMMMMMMM ut 3 N s M.s. @.,. @. c. e.M.N. M. M. O. O.@.@.v.e. M. e.@.C.N.e. M. h.h N.e. M.@.h.N. Q. c.@.,.N. @. @. o @TN=N9@@@TM@eO@T@@5NeehMT@M=N=MMMNMgTNN f 9 e @ O = N M v.= N M T @ @ N e @ O = N M 9 @ @ h e @ O = N M 4 = N M V @ @ h e eeNNNNN

===e==e =e.=NNNNN r 1 I l l t 4 ~

p\\ t. tt k 'w/ [\\ 't ) 2 N e W W DE m 3 wd a 1 = 34 23 h Ew 3 E m 4 h > c Z O ~ U h. QU M. N. @ N. T. N. =. C. O. T. T. T.. O. *. *. M. 4. h @ @ @ @ h. M. N. =. =. h. N. T. e. h. o. h C. C. O. =. h @ C. N. 9 9 9. N - N. -d

====================O000000000=Q====CO---=*

hw l i s t 6 l e s 6 a s i I e t i e e t e t i e i e t i e s e a e i n s i s e e i e s e i s t U C0 h w h O O he 0w0

e. M. e. e. @. M. 4. *. @. @. M. T. Q. a @ @ @ @ O. M. M. @. @. M. M. O. @. N C. O. O. =. M. @. @. @. M. c. @. M N. @. @. h m. e. @

w E 3 00 MM@@N@a@hC=9@TO=@@NONTeTe@MM@h@h*=N@@=@OT9-wcec@M T @ @ @ @ @ @ T @ h. h. @. @. @ h. h. h. e. N N N N T @ N..= M M. N =

  • T.T N. M. M. W @. 9 0 @ h M @ N N M M OO~~e..

W = 3 w... .NNMMMM e b -e....... 33 0 3 E = N N O. & e.M.h.N.T.N.e.@.@.@.M. M. c.Q.C. @.=. @.@.h.h. e. @.v.h. M.c.h.N.@. @.9.e.@.N.@.g @ @ M.N.T.4 0.@.w.e.O.N. T e a q N. W @. b h. c Q N O @ @ @ h N e m c. h @ @ O 4 T h e c t @ @ @ @ T @ @ @ @ T @ c h @ T M M M T @ m e W W e3 6 s 3 g w E \\v) we e@O-NM,-NMe@@he@Q-NMT@@he@O.NMe-NMe@@he@C-NMecche 33 --NNNNN =m---w NNNNN m W

.._..__.-4_m. ..m ..___m o___ .._____m_._m_ i l i 4 e l i s I l 5 i 'l i d i i I 1 l I. l 1 4 i s I N 9 m a m> 9 N W = 3 Z = 3 h 339 N T. M N. O. e. c. h. @. e. @. M. @. @. =. m. c. @. @. @. o. e t. N N. @. @. =. N m. 8. @. =. 9. M. 9. c. h. M. m

====CocococcQOO-=*=N==CO-NMMMMNMMMM9oo I i i ee a 6 6 4 e a e I e a 6 4 t t t i e e a = b Ow @ * @ = N. T. @. e. 9 @ @ M. e. T. e. @. @. @. =. =. @. @. 9. N. M. Q. W. M. N. M. @. @. @. @. @. ~. N. C Q MO@Mookp==NNhh@M@9MS@=OOM@hc@=T=h@9-@~ MMNNNN=COCOOOehe@@@@@@@9MN=NNM==N=Oc@C MMMMMMMMMMMMMNNNNNNNNNNNNNNNNNNNNNNN=N W I = W N h. h. W. 9. e. @. =. @. @. @. @. @. e. =. @. @. @. =. @. =. e. h M. N. C. @. @. 9. N. @. e. Q. 9. =. Q. @. &o Nemese@@@bm@TMT@@@M@Q@@@NSCONQ*De@N=NO =

==

==

G @O-NM9=NMT@@he@C=NM9@@Ne@Q=NM9aNMT@@Ne =NNNNN

==========NNNNN

f ) \\ / %s e M \\ >) m. i ~> T W 33 = 3 w0 0 2 N 34 23 h O Z I u 32 = N b h e Z O u o @ @ @ @ a - C. O

  • O. - N @ g g @ @ @ h h @ 9 0. N. w. N. @ c. t. @. = @ N N. M. M. v. @. w h. @. @. e. @. h @ M. N. T.

M OU N

0 0C09-=================

=========================O >w e e e a 4 e e i e i e i e i e e t 6 e e e i 4 e e e a i e a e e e e a s s a e e e a e e t i e e i U 00 e W h Q O Ne 00 W e. s. *. @. @. M. M. a @ = C. o. c. a t. c. h a Q M. h. @. @. @. =. 4 0. @. M. *.. M. M. M. h. h e. Q. @. N, e c. @. M 4. @. T. c. w -w E 3 OQ @@@eO*eO@@NWOM=w9megeze=@=cQ909@@eh@ht@gh@mewhhem W = B M eMWM-NNNN-NNNNNNNNNNMMNMMNNNNN===-NN=MgTWW9T9NO e h M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM 33 0 2 Z = N N f M 2 QT @ @ @ N. O. O. @. @. C. h. e. q @ h e. @. h @ h. @. h. p @ M. N h. n e. h. @. h g @ e. C. h @ @ @ @ g M. e g o. 4.. @. C. c. 9 9 .C W > A3 MMNMM99@eheeOOOOOOONOOce@@@@@@@@994TMMMT@h@@@9mMM r 4 + R =* ( ]h \\ w E O = ~ M, = N e. @ h e. Q. ~ M , @ h. e @ O - N M. = N e., @ - e @ C - ~ M.., @ h e. @ N .O m. 33 NNNNN .=NNNNN .=c. = N i

t i G G 9 J 21 3.0 300.9 -0.5 22 3.2 302.6 -0.2 i 23 2.9 299.6 0.2 24 2.3 297.4 0.1 1 1.9 286.5 0.5 2 1.5 257.2 -0.1 3 1.6 283.0 -0.3 4 1.6 279.0 0.5 5 7.4 295.6 0.5 6 f.7 206.0 0.6 7 1.3 202.0 1.1 8 f.4 295.8 1.7 9 2,1 290.6 f.6 10 2.4 306.8 0.4 11 2.2 347.2 -l.6 12 2.1 329.7 -l.7 73 t,9 30s.5 -0.9 14 3.7 83.2 -3.9 15 3.6 192.3 -1.7 16 3.1 239.5 -1.9 17 9.9 31.7 -1.3 38 1.3 49.3 0.9 l 19 1.5 168.0 0.4 l 20 1.6 104.5 0.5 21 4.7 97.t -1.2 22 6.9 94.3 -1.4 23 4.0 63.5 -1.5 24 5.5 60.3 -1.4 1 5.5 78.9 -1.5 l 2 6.t 98.6 -1.5 3 6.2 72.2 -0.4 4 9.t 65.8 -I.2 5 7.6 101.8 -1.4 6 3.3 137.6 -1.2 7 -99.0 105.4 -0.2 8 -99.0 96.7 -1.8 l 9 -99.0 102.4 -0.0 10 -99.0 100.4 -1.4 f 11 -99.0 114.3 -1.3 12 -99,0 190.2 -1.0 i l 13 -99.0 107.0 -1.0 14 -99.0 199.9 -0.0 95 -99,0 920.5 -1.2 16 -99.0 74.9 -0.9 17 -99.0 67.1 -0.8 18 -99.0 64.8 -0.8 j 19 -99.0 32.6 -0.9 20 -99.0 57.6 -0.9 29 -99.0 18.3 -1.2 22 -99.0 349.2 -1.0 23 -99.0 359.5 -1.4 24 -99.0 12.4 -1.4 1 -SS.O 7.0 -1.2 Stop TIME DEC 28.1987 HOUR 0 MINUTE 28 VI-94 j f f.---- j

9 O e l l I 1 e RELEASE MUesBER 87079 CONTAINMENT PURGE STARTING TIWL DEC 31.1987 OUR 17 MINUTE 43 TIME wit 0 wD10 0Ttt0 HOUR esPet DEG DEG C l 17 8.9 303.5 -l.5 18 7.4 304.2 -I.4 f 39 5.3 301.9 -3.7 ( STOP TIME DEC 31.tJ87 HOUR 18 MINUTE 2 ERROR RELEASE NO. 8707913 PA5T STOP [ r l 4 4 i t 1 4 \\ I f VI-95 _, l

..--..~.-..=a..~-... ~... _,. _. = _.. =. -... - -. - - - - - ~...... _ - - - i t i d I 8 i 1 4 5 ii .i i i !O t a f i l a i i G e e M l W t \\ ~ 3 e Z l w a 3 W N Z d

== 3 3 p 2 a 3 e 9 x Z 3 4 3g h 4 e u W Q Pn M QU * * = N.N.N.N.N. e N = ad Q0000C00 >w 4 e e i 4 .J QQ M 3 N O 7 Q k J e 3 00 @

  • M.@.M.S.e.@.

9 w -w 2 3 OC ONT*@C=@ 3 k e. e m m e s. e W

== g p.

  • e e = a= e e =

3 w 3 0 3 3 .E. W M N OT M. @. @. @. P= e. P= c. q q d O W W @3

    • N O @ Q @ @ ** >

.J e E

  • * = = = = =
  • e G

w E W NMT@@he@ 3

f O O O t l f RELEASE MuwSER 87010 DECAV TANK PURGE STAstTING TIME AUG 5.1981 HOOR 17 MINUTE 1 } i TIME wSIO w010 OfIto i Houa MPH otG DEG C 17 11.6 157.8 -1.1 18 St.O 151.9 -1.0 19 10.7 136.5 -0.8 20 9.8 140.6 -0.5 21 7.9 140.7 0.5 22 9.0 150.3 0.8 i i i STOP TIME AUG 5.1987 HOUR 25 MINUIE 47 I l i I t 1 h I 6 L i f r i L h I I t [ VI-97 t . -.........,,. _.. _ _ - - - -,... _, -. - _ _ _ - - _ _. - _. _ _ _ _. -. - - ~._.- __ _ _____ _ -.._.-_ ~.. I

i 1 RELEASE NUMSLR 87018 OECAY TANK PURGE STARTING TIME AUG 13.1987 HOUR 12 MINUTE 36 l 1 TIME WSIO WD10 DTilO HOUR MPH DEG DEG C 12 4.7 62.0 -1.5 13 3.6 85.1 -I.4 14 5.0 116.7 -1.2 STOP TIME AUG 13.1987 HOUR 13 MINUTE 43 i i I l I VI-98

(& RELEASE NUMBER 87012 DECAY TANK PUR' E i STARTING TIME AUG 26.1987 HOUR 22 MINUTE 2 i TIME WS10 WDIO DT110 HOUR MPH DEG DEG C 22 3.6 334.4 -0.3 23 3.0 322.1 -0.1 24 2.1 312.4 0.3 l 1 3.2 317.7 0.1 2 3.6 324.3 0.1 4 l 3 3.3 329.9 0.5 i 4 3.5 328.7 0.4 STOP TIME AUG 27,1387 HOUR 3 MINUTE 56 f t T i 4 t 1 I 1 1 j i VI-99 6

OO m l m> M M W CD 3 N Z = W 2 "3 W N Z O - E 2 D E 4 3 S O

  • I Z

c 4 3 0 >= b ~ f' 4 U W = P. Q QU @ N. N @ @ N.. 4 mm N e .- d.-- ---o k >W I e 1 I I I i e L QQ M W N M Q k P. 23 W CO

5. @. iD. @. M. M. to. e. e W

-W t 2 2 OQ N e @ @ Me- @ c [ W = 3 MNMMMMNM l C H MMMMMMMM 2 W 3 0 2 Z Z

== l =. l W k l A 2 OI O.W.M.N.N O.M. @. 4 4 -a o W P-M2 @@O.OQ@@ =. = - e .J e 3 W E N.= M 4 @ @ N C @ WM 33 =-- Y ,-4

l._ _ _ _ _. _ _ _ _ _. -. - - - _ _ _. _ _. _,. _ _. .. _. _. _. _.. - -.... _... ~. .m. ~. -y.. w t Y g t t- -:s- ~

y

- h I RELEASE NUM8ER 87014 OECAY TANK PURGE l STARTING TIME NOV 12.1987 -HOUR 3 MINUTE 7 -? 1 l TIME WSIO tvd 10 OT110 . i. i HOUR MPH DEG DEG C 3 3.7 155.6 -0.4 4 4.2-152.4 -0.1 5 6.6' 209.3 0.6 i STOP TIME NOV 12.1987-HOUR 4 MINUTE 7 j. ' l STARTING TIME NOV 12.1987' HOUR' 4 MINUTE 9 r i TIME WSIO WD10 OT110 q HOUR MPH DEG DEG C 4 4.2 152.4 -0.1' 3 t 5 6.6 209.3 0.6 i 6 3.. 163.5 -0.4 s 7 4.2 158.9 0.2 8 d.3 179.2 -0.1 9 3.0 187.0 -3.6 l-STOP TIME NOV 12.1987 HOUR 8 MINUTE I-i I 4 t i h I E a . s r L i 1 .[ ~ 0 l i 4 1 -L l i 1 ) 1 - t i 1 7 i ) - VI-101- .f I a ~ s 4' -.-r----.. ,,...---..-,m.c, m...... .. - -, -. -,,, =,. .--._,._m, ..~

1 i I REL E ASE NUMOER 87014 DECAY TANK PURGE STARTING TIME NOV 12,1987 HOUR 10 MINUTE 12 TIME WS10 wD10 DTIIO HOUR MPH OEG OCG C 10 5.0 208.7 -1.7 11 6.4 226.7 -1.7 12 7 *.1 240.8 -1.0 l STOP TIME NOV 12.1987 HOUR 11 MINUTE 56 l i i .i i I t 1 1 1 l 1 i t 1 l i j i VI-102 4 i i l 1

m i Y: (- 3 4 I i t 1 RELEASE NUMBER 87015 DECAY TANK PURGE I STARTING TIME NOV 19,1987 HOUR 17 MINUTE 28 TIME WSIO WD10 DTt10 HOUR MP14 DEG DEG C 17 8.5 293.0 -0.7 l 18 5.9 285.4 0.3 i 19 5.2 293.4 0.2 l 20 5.2 294.4 0.5 l 21 5.7 309.7 -0.1 22 4.8 314.0 0.3 23 5.3 333.0 1.4 l STOP TIME NOV 19.1987 HOUR 22 MINUTE 47 i l 1 i i I I 1 i j l i 1 l 5 VI-103 W

"N NLLEASC NUMOEP 37016 DECAY TANK PURGE STARTING TIME DEC 31.1987 HOUR 3 MINUTE 16 TIME WS10 WD10 DT110 HOUR MPH DEG DEG C 3 9.2 285.5 s.2 t 4 7.2 275.5 -1.3 l 5 7.7 276.1 -1.0 6 5.7 277 e -1.1 7 6.2 2~4.9 -4.1 STOP TIME DEC 31.1987 HOUR 6 MINUTE 46 STARTING TIME DEC 31.1987 HOUR 11 MINUTE 5 l TIME WSIO WD10 DT110 HOUR MPH DEG DEG C 11 11.0 319.8 -2.0 12 12.4 313.2 -1.9 13 11.6 304.2 -2.2 14 12.6 301.5 -2.1 15 11.5 300.7 -2.0 STOP TIME DEC 31.1987 HOUR 14 MINUTE 39 f a f I l l VI-104

l;;:n 'e SECTION VII . POTENTIAL DOSES TO INDIVIDUALS AND POPULATIONS (RegulatoryGuide1.21) July 1, 1987 to December 31, 1987 'l O O VII-1

POTENTIAL DOSES TO INDIVIDUALS AND POPULATIONS A. Potential Semiannual Doses to Individuals from Gaseous Releases Total body, skin and organ doses from ground releases were calcu-lated in millirem (mrem) to an average adult, teenager, child and infant using the annual configuration of the GASPAR program. Re-suits to each receptor are shown in Tables VII-A-1 through VII-A-34. Also, the doses to the same groups, Table VII-B-1, in units of millirads (mrad), due to gamma and beta radiation carried by air, were computed using GASPAR. In its annual configuration, GASPAR assumes that all release rates are entered in curies per year (CI/yr). If the total curies released per isotope during the semiannual period are assumed released for an annual period ( (CI/yr), this release rate reduction is conveniently offset by the annual usage or dose factors, thereby allowing GASPAR to calculate semiannual doses. The inputs to GASPAR for the semiannual period from July 1,1987 through December 31, 1987 were as follows: (1) All gaseous effluents were as described in Section III. (2) Entrained gases (Xe-133 and Xe-135) from liquid effluents were described in Section IV. O VII-2

(3) Semiannual "X/Q's" at the actual receptor locations, which were corrected for open terrain, plume depletion, and radio-active decay factors were calculated according to Regulatory Guide 1.111. Also included were semiannual deposition rates corrected for the open terrain factor. (4) The production, intake and grazing fractions were as fol-lows: 1.0 for fresh leafy vegetation grown locally, 0.5 for the pasture grazing season, 0.76 for vegetation intake grown in gardens,1 for daily intake of animals while on pasture 3 and 8 g/m for the air water concentration. (5) All dose factors, transport times from receptor to individ-ual, and usage factors were defined by Regulatory Guide 1.109 in GASPAR. l (6) Site specific information, within a five mile radius of the plant, on types of receptors located in each sector was used. That is, if a cow was not present in a sector, then the milk pathway for that sector was not considered. If it was present, then its actual sector distance was used. These inputs introduce a most conservative approach for the follow-ing reasons: (1) The open terrain and deposition corrections increase semi-l annual "X/Q's" by a factor ranging between 1.0 and 4.0. lO VII-3 l l

i (2) The production, intake and grazing fractions, as defined in r _ (V~~') the input definition statement, represent an environmental area in an extremely conservative manner. B. Potentia: Semiannual Doses to Population from Gaseous Releases The GASPAR program in its annual configuration was also used to calculate the ALARA integrated population dose sumary for the total body, skin and organ doses in manrems for all individuals within a 50 mile radius population. Results are shown in Table VII-C-1. The population integrated dose is the sumation of the dose received by all individuals and has units of man-thyroid-rem when applied to the sumation of thyroid doses. The same inputs were used as in the individual case with the addition of the following: (1) A total population of 734,668 based on the 1980 census, was used to define the sector segments within a 50 mile radius of the plant, s (2) Total productions for milk, meat and vegetation were based on 1973 annual data for Nebraska as recomended by the NRC for use in GASPAR. O VII-4 i

C. Potential Semiannual Doses to Individuals from Liquid Releases Total body, skin and organ mrem for liquid releases were calculated for all significant liquid pathways using the annual configuration of the LADTAP program. Dose conversion factors used by LADTAP for ingestion and shoreline deposition are shown in Table VII-0-1. Results are shown in Tables VII-0-2 through VII-D-9. The inputs to LADTAP for the semiannual period from July through December 1987 were as follows: (1) All liquid effluents were as described in Section III, except for the entrained gases (Xe-133 and Xe-135). O (2) A plant discharge rate of 802 cubic feet per second (CFS) or 8.02E+02 was used. (3) Dilutionfactors(inverseofthemixingratios)werecomputed basedonRegulatoryGuide1.113(equation 7inSection2.a.1 of Appendix A) for a one-dimensional transport model. I 1 l (4) A drinking water transport time of 6.6 hours to the Omaha intake and 7.0 hours to the Council Bluffs intake for the ALARA doses in Table VII-0-2 through VII-D-5 was used. For Tables VII-D-6 through VII-D-9, a transport time of 0.0 was l used from the plant to the discharae site. O VII-5 s, ~ ~, ~

(5) A shorewidth factor of 0.2 was used. d (6) All consumption rates, using rates, and transport times from receptor to individual were as defined by Regulatory Guide 1.109 in LADTAP. The discharge site in Tables VII D-6 through VII-D 9 was chosen to present a most conservative estimate of mrem dose for an aver-age adult, teenager, child and infant. A conservative approach is also presented.by the assumption that Omaha and Council Bluffs re-ceive all drinking water from the Missouri River. D. Potential Semiannual Doses to Population From Liquid Releases The LADTAP program in its annual configuration was also used to calculate the total body and organ doses for the population of 734,668 within a 50 mile radius of the plant. Results are shown in Tables VII-E-1 through VII-E-6. The same input was used as in the individual cases with the addition of the following: (1) Dilution factors and transport times for the pathways of sportfish, commercial fish, recreation and biota were cal-culated based on a distance of two miles downstream as approximately the distance to the nearest recreational facil-ity - DeSoto Bend National Wildlife Refuge. O VII-6

. _ _ = _. (2) The total fish harvest for both sport and commercial purposes ) was calculated using an average commercial fish catch for Nebraska. l E. Direct Radiation Doses to Individuals and Population Direct radiation doses, attributed to the gamma radiation emitted from the containment structure, were not observed above local back-ground at any TLD sample locations for this semiann~ual period. O i i l r O VII-7

._ ~.- ~.- 1 r 4 hs 4 4 ) i i 4 l TABLE VII-A-1 1 i F FORT CALHOUN I RECEPTORS IN ALL SECTORS 02-08-88 SPECI AL LOCATION s I RES AT 4.53 MILES N RETA AIR DOSE = 1.99E-04 MILLRADS GAMMA AIR DOSE = 9.8tE-05 MILLRADS PATHMAY T.SODY GI-TRACT SONE KIDNEY THVROID LUNG _________.__________.__________.-_________.__ LIVER ________.__________.__________._______ l 6.04E-05 l 6.04E-05 l 6.04E-05 l 6.04E-05 l 6.04E-05 l 6.22E-0 PLOME _________.__________.__________.__________.l_6.04E-05_________.__________.__________.__ l 1.46E-04 l GRouMo l 3.47E-08 1 3.47E-08 l 3.47E-l 3.47E l 3.47E-08 ! 3.47E-08 l 3.47E-08 4 _________.__________.__________ _______08___._______-08___.________. .__________.__________.l___.2tE-08l INHAL l l l l l l l l j ADULT l 6.6tE l 6.66E-07 l 2.84E-07 l 7.07E-07 7.74 l 1.65E-05 l 6.38E-07 l 6.16E-0 _________.-______-07___.__________.__________.__________.l_____E-07_____ ______.___.__________._________7 l TEEN l 6.78E-07 l 6.78E-07 l 3.27E-07 l 7.46E-07 l 8.40E-07 i 2.16E-05 6 l 6.20E-07 l ___.__________.__________.__________.l___.58E-07 CHILo l 6.14e-or l 5.78E-or l 3.39E-07 1 6.73E-07 1 7.55E-07 l 2.70E-05 _____.__________.__________ __________.l__5.82E-07l 5.4aE-C7 l INFANT l 3.58E-07 l 3.27E-07 l 1.78E-07 l 4.32E-07 l 4.52E-07 l 2.47E-05 ____.__________.__________.__________.l_3.4tE-07_ _ _ _ _ _ _ _ _. _ _ _ _ _ l 3.15E-O VII-8

t 1 x /- t I i i 4 i i 1 TABLE VII-A-2 1 J l FORT CALHOUN I RECEPTOR $ IN ALL SECTORS 02-08-88 $PECIAL LOCATION a 2 VEG.RES AT t.86 MILES NNE l 8 ETA AIR DOSE = 3.06E-03 MILLRADS GAMMA AIR DOSE = 5.53E-04 MILLRADS i PATHWAY .T.800v GI-TRACT SONE MIDNEY THvROID LUNG t _________.__________.__________.__________.__ LIVER __-_____.__________.-________-..________.____ 1 eLumE l 3.43E-04 l 3.43E-04 1 3.43E-04 l 3.43E-04 1 3.43E-04 l 3.52E-04 1 .__________.13.43E-04-_______. .______--__.__ _______.._________.l 8.08E-04 cRouuo l 3.76E l 1.76E-07 I s.76E-07 l 1.76E-07 1 l 1.76E-07 l 1.76E-07 l 2.14E- \\ _._-_____,_______-07___._______.._._________,___--___...l___.76E-07___-___.___-______..__~_-_-__ __._____07 l J vEGEr i l I l l 1 I l l AouLT l i.39E-05 l 6.97E-06 1 3.24E-05 l 6.77E-06 ) f.62E-04 l 5.78E-06 I _________.___-______.____--____.___----___.l_6.36E-06_____--__.__-_-___-- --_-___-__...._______.1 5.78E-06 1 TEEN I t.67E l 7.93E-06 l 4.OIE-05 l 7.tSE-06 7 l 1.37E-04 l 6.62E-06 l 6.62E-06 ____--_-_._______-05___.__________.__________.-________..l___.54E-06_______.__________ ___._---..-___.i j CHILo i 2.73E-05 I I.13E-05 l 6.64E-05 l 1. TOE-05 l 1.14E-05 l 2.14E-04 l 1.03E-l 1.03E-05 1 l -______.....-_-___..-_____05 IMHAL l l l l l 1 l l 1 j AOULT l 3.46E-06 1 3.48E-06 l 1.62E-06 l 3.71E-06 l 4.00E-06 l 9.06E+05' -________.__________.__________.____..____.______. __,__________._-..____-..I 3.33E-06 1 3.20E-06 i TEEN I 3.55E-06 l 3.55E-06 l 1.86E-06 l 3.92E-06 l 4.44E-06 l 1.19E-04 1 3.23E-06 l i . _________.__________.__________.l_3.44E-06 5 CHILD l 3.22E-06 1 3.02E-06 l 3.92E-06 l 3.54E-06 1 4.00E-06 l 3.48E-04 ~ ___._____.___-.____-. ______-_.__________._______-__._________..l_3.05E-06l 2.85E-06 l INrAwT I i.88E-06 I i.7 E-06 I t.00E-06 1 2.29E-06 l 2.40E-o6 l *1.36E-04 l 1.64E-06 l _.__________.__________.__________.______.___.l.3.79E-06 l l l 1 1 4 4 4 VII-9 i d ,w w- -a,--w, m-w ,-w-n- --v-e w

~ 1 1 4 l. i 4 f 1 + i f i 1 TABLE VII-A-3 1 i i J FORT CALHOUN I RECEPTORS IN ALL SECTORS 02-08-88 SPECIAL LOCATION a 3 RES j AT 3.47 MILES NE 4 BETA AIR DOSE = 1.38E-03 WILLRADS GAMMA AIR DOSE = 7.41E-04 MILLRADS i y PATHwAv T.eODY GI-TRACT BONE LIVER K THvROIO LONG SKIN i I _________.__________.__________.__________.__________.____IDNEY PLDME l 4.60E-04 l 4.60E-04 l 4.60E-04 4.60E-l 4.60E-04 l 4.69E _________.__________.__________.__________.l______ 04___.__________.______-04 l 4.73E-04 l 1.07E-03 l i GROUND l 1.92E-07 l 1.92E-07 l 1.92E-07 1.92E-l 1.92E-07 l 1.92E-07 l 1.92E-07 l 2.33E-07 _________.__________._-________.__________.l_______07___.____--____.__________.._____ IMHAL l l l l l l l l l ADULT l 4.48E-06 l 4.5tE-06 l 2.12E-06 4. l 5.29E-06 l 1.19E-04 l.4.3tE-06 l 4.84E-06 _________._______-__._______.__.__________.l___80E-06_______.__________.__________.______ l TEEN l 4.60E-06 l 4.59E-06 l 2.44E-06 5.08E-0 l 5.76t-06 l 1.55E-04 l 4.46E-06 l 4.87E-06 -_-______,___-___--..__________._____-____.l________6__.______-___.__________.__________,__________.l CHILD l 4.17E-CS l 3.9tE-06 l 2.52E-06 4.59E _________.__________.__________ __________l_______-06l 5.19E ___._______-06 l 1.94E-04 l 3.94E-06 l 3.69E-06 l f INFANT l 2.43E-06 l 2.21E-06 l 3.32E-06 2.97 l 3.IIE-06 l 1.78E-04 l 2.32E-06 l 2.12E-06 _________.__________.__________.__._______.l_____E-06_____.__________ __________.__________.__________.l 3 i i I i F l. l VII-10 l ( 1

.h - [m.i ' ) / 6 TABLE VII-A-4 FORT CALHOUN 1 RECEPTDRS IN ALL SECTORS 02-08-88 SPECIAL LOCATION s 4 VEG AT 3.54 MILES NE BETA AIR DOSE = 1.25E-03 MILLRA05 GAMMA AIR DOSE = 6.70E-04 MILL 9 ADS PATHWAV T. BODY GI-TRACT 80NE LIVER MIDNEY THvROID LUNG _.________.__________.__________.__________.__________.__________.__________.__________.___ SKIN PLUME l 4.tSE-04 l 4.15E-04 l 4.tSE-04 l 4.15E-04 l 4.15E-04 l 4.15E-04 l 4.27E-04 9 l _________.__________.__________ _______.__.__________.___,______.________._ __________l___.72E-04 GROuNo l 1.68E-07 l 1.68E-07 l 1.68E 7 l 1.68E-07 l 1.68E-07 l 1.68E-07 l 1.68E-07 l 2.04E-07 i VEGET l l l l l l l l l ADULT l 3.46E-05 l 7.97E _________.__________._______-06 l 3.00E-05 l 7.38E-06 l 7.78E-06 1 1.56E-04 l 6.84E-06 l.6.84E-06 l TEEN l 3.74E-05 l 9.07E-06 l 3.8tE-05 1 0.33E-06 I 8.70E-06 l 1.32E-04 l 7.83E-06 7 _________.__________.__________.__________.__________.__________.__________.__________.l___83E-06l CHILo l 2.83E-Os l i. sic-05 l 6.siE-oS l i.28E-oS l i.32E-oS l 2.06E-04 l 1.21E-05 l 1.2tE-05 l InHAL l l l 1 l l l l t ADULT l 4.09E-06 l 4.12E-06 l 1.94E-06 l 4.39E-06 l 4.84E-06 l 1.08E-04 l 3.94E-06 I 3.79E-06 l TEEN l 4.20E-06 l 4.20E-06 l 2.22E-06 l 4.64E-06 l 5.27E-06 l 1.42E-04 l 4.07E-06 l 3.8tE-06 l CHILD l 3.81E-06 l 3.57E-06 l 2.30E-06 l 4.19E-06 l 4.74E-06 l 1.77E-04 l 3.6tE-06 l 3 37E-06 l INFANT l 2.22E-06 l 2.02E-06 l 1.20E-06 l 2.71E-06 l 2.84E-06 l 1.62E-04 1 2.12E-06 l S.94E-06-l i I d i i VII-11 m

CA. / \\ j \\s_e - t 4 ? 4 ? 4 I t t ? ) TABLE VII-A-5 1 FORT CALHOUN 1 RECEPTORS IN ALL SECTORS O2-08-88 SPECIAL LOCATION a 5 RES.vEG AT 4.79 MILES ENE SETA AIR DOSE = 1.36E-04 MILLRADS GAMMA AIR DOSE = 5.88E-05 MILLRA05 PATHwAv T.BOOV GI-TRACT SONE LIVER KION .-------- -------- -,-- ------- ----------.---------- ----- EY THYROID LONG SMIN PLUME l 3.57E-05 l 3.57E-05 l 3.57E-05 l 3.57E-05 3.57 l 3.57E-05 l 3.70E-05 l 9.15E-05 l


.----------.---- ----- ----------,--.-------.l---- E-05 GROUNO l 8.06E-09 l 8.06E-09 l 8.06E-09 l 8.06E-09 8

l 8.06E-09 l 8.06E-09 l 9.79E-39


,----------.----------.----------.----------,l--.06E-09-------.----------.----------,----- ----.l VEGET f

l -l I I i 1 l l Aouti l i.17E-06 l 8.40E-07 l 3.55E-06 l 8.10E-07 8.30


,----------+-------

-..----------.----------,l---. E-07 l 8.17E-06 l 7.84E-07 l 7.84E-07 l~ TEEN l 1.38E-06 l 9.59E-07 l 1.92E-06 l 9.22E-07 9 ---_ ----.----------.----------.----------.----- ----,l--.40E-07 l 7.05E-06 l 8.97E-07 l 8.97E-07 l CHILD l 2.20E-06 l 1.44E-06 l 3.18E-06 l 1.42E-06 l t.44E-06 l 3.10E-05 l 1.39E-06 1 l


,----------,----------.-----..--.----...--.l -.39E-06 INHAL l

l l l l l l l l ADULT l 4.65E-07 l 4.68E-07 l 1.97E-07 l 4.96E-07 l 5.4tE-07 l 3.12E-05 l 4.50E-07 l 4.34E-07


_.------_- -.-- -------.- ---- -_-.---...-.-.l TEEN l 4.77E-07 l 4.76E-07 l 2.26E-07 l 5.22E-07 l 5.86E-07 l 1.46E-05 l 4.63E-07 4.37


...l --..E-07 l

CHILD l 4.3tE-07 l 4.07E-07 l 2.34E-07 l 4.7tE-07 l 5.20E-07 l 1.83E-05 4.10E-07 l --._----__.... ------.--------......------.l_--------..l_3.86E-07 INFANT l 2.5 t E-0 7 l 2.30E-07 l 1.23E-07 l 3.OtE-07 l 3.ISE-07 1.67E-0 l 2.40E-07 l 2.22E-07 l ..-_-- --- _.--__-- --.,_---------.-- --- ---.l-_.---- 5 VII-12

.. ~.-. 4 s d. 4 3-4 i i i 1 l 4 1 2 TABLE VII-A-6 1 i I FORT CALHOUN I RECEPTORS IN ALL SECTORS O2-08-88 I SPECIAL LOCATION s 6 RES AT 4.67 MILES E .8 ETA AIR OOSE = 2.40E-04 MILLRADS GAMMA AIR CDSE = 3.OIE-04 MILLRAOS 1 PATHwAv T.800v GI-TRACT SONE LIV i _______._._..______.___---._ _,.__._.-___._.__.ER KIONEY THVROIO LUNG SMIN l PLUME l 6.13E-05 l 6.13E-05 l 6.13E-05 l 6.13 l 6.13E-05 l 6.13E-05 l 6.36E-05 l 1.59E-04 l ___. - __._._.-_..___---.__.._.___-.__...___E-05_.___.--________._________.._________..____.-_-_.l GROUND l l.39E-08 l 1.39E-08 l 1.39E-08 ! t.39 l 1.39E ___._____.__________._--._____.__._______._. -_E_08___.______-08l 1.39E-08 l 1.39E-08 l 1.69E-08 l INHAL l l l l l l l .l l' AOULT l 8.29E-07 1 8.33E-07 l 3.51E-07 l 8.82E-07 l 1.98E-05 l 8.OIE-07 1 7.74E-07 _.._____.-____-____.___. _ --_.__.---___.__________.l_9.63E-07_______. . ___._____..-_______....._______.l j TEEN l 8.49E-07 l 8.47E-07 l 4.03E-07 9 l 3.04E-06 l 2.59E-05 l 8.26E-07 7 ___.._____.l___.29E-07_______..-_.--____.--_-______. _-..___.l___.78E-07 l' 1, ______-__...--_--_-_._____-.__ +___.._-_...l_____E-07.--__. _.--_-07 l 3.23E-05 l T.31E-07 l 6.88E-07 l CHILO l 7.68E-07 1 7.25E-07 l 4.16E-07 8.37 l 9.35E 1 4 INFANT l 4.47E-07 l 4.10E-0 7 l 2.18E-07 l 5.36 l 5.59E-07 l 2.95E-05 l 4.28E-07 l 3.96E-07 __._____E-07_____.___.. _____..________..l t i i l i i 1 1 J i f 1, 4 I b t k i VII-13 4 1 k . ~.

j_ ..__m. m._. ' L-J s q 't .l /"T'N 7 l 1 4 t 4 i i 1 .. i' ( i { 't i TABLE VII-A-7 t u l l FORT CALHOUN I RECEPTORS IN ALL SECTORS 02 d4-6't l SPECIAL LOLATION s 7 VEG 3 At 5.03 MILES E l l. l BETA AIR DOSE 2.lOE-04 MILLRADS = 1 l GAMMA AIR DOSE = 8.60E-05 MILLRADS ? i PATHWAY T. BODY GI-TRACT SONE LIVER MIDNEY THYR LONG SKIN _________.__________..-_.._____._________..______OIO I PLUME l 5.19E-05 l 5.19E-05 l 5.19E-05 l 5.19E-05 l 5.19E __-______.____..__. ________..________--.__________.__________.15.19E-05____.-____.-_ l 5.39E-05 t 1.37E-04 l l GROuMo l s.20E l't.20E-08 l t.20E-08 l 3.20E-08 l 1.20E-08 l 1.20E-08 1.20E-0 1 1.46E-08 l _________._______-08___._____.___.___.---___.____--____.___-._____._....______.l________8 VEGET l l l l l l l l .I AOuti l i.82E-06 l .32E-06 l 2.36E-06 l 1.27E-06 l 3.30E-06 l i.23E _________.____..____..________-.__________.._________.._________.l__1.24E-oS_______..l.i.23E-06__________._______ l-ieEN l 2.i4E-06 l i.5ic-06 1 2.92E-06 l 1.45E-06 3.48E-06 3 _________.__________.________..__________.__________.l_________..l___.0FE-05 l 1.4tE-06 l 1.41E-06 l CHILD l 3.43E-06 l'2.26E-06 l 4.84E-06 l 2.24E-06 l 2.27E-06 1 ~ ; _________.-_________.___.______.__________,_-________._______-_.,l__.66E-05 l 2.19E-06 l 2.19E-06 l ..j \\ t 'A I t q 4 L t . I I L P VII-14 l'

(/ ~ i t i 1-1 a i 1l' TABLE VII-A-8 1 l 1 4 FORT CALHOUN t RECEPTORS IN ALL SECTORS O2-08-88 j SPECIAL LOCATION # 8 VEG ,i i AT 3.18 MILES ESE i 8 ETA AIR DOSE 8.35E-03 MILINAD5 = i GAMMA AIR DOSE 4.50E-03 MILLHADS = PATHwAv T.SOOY GI-TRACT BONE LIVER MIONEY THvRO LONG SKIN


_---_,-_--------.---_--__--+------_---,_-------_-,----_-----,-------ID _-,----_---_-.-_----_---,

PLUME l 2.79E-03 l 2.79E-03 l 2.79E-03 l 2.79E-03 l 2.79E-03 2.79E-03 l 2.87E-03 l G.5tE-03 1


_----,---_-_----,__-----_...--__-----_.------__-_,_-----_---,I j

GROUND l 8.55E-07 l 8.55E-07 l 8.55E-07 l 8.55E-07 l 8.550-07 8 l 8.55E-07 l 1.04E-06 l


_,---___----,----------,-___--_---,-_----_--_,_-_----__-.l--.55E-07 l

l VEGET l l l l l l l l l Aouti l 8.47E-05 l 5.ItE-05 l 1.56E-04 l 4.82E-05 l 5.02E-05


_--,_-----_-__.-_-_------.---_-_-_--.--------_.._-----_-,l_8.04E-04 l 4.54E-05 l 4.54E-05 l TEEN l t.OIE-04 l 5.83E-05 l 1.94E-04 l 5.45E-05 l 5.64E-05 6

__--_..--,_--------_.-__-------,-___------,----_--- c.-----_----,l--_.84E-04 l 5.20E-05 l 5.20E-05 l CHILO l t.63E-04 l 8.54E-05 l 3.2tE-04 l 8.39E-OS l 8.GIE-OS l 1.07E-03 l'8.050-OS l 8.05E-05 l [ t i 4 1 i 1 i I i .t l ) i l d i ] I i i 1 VII-IS .I t 4- -n- -n,.,-- -me ~,, re- -, ~ ~.,.,, a, ---n,- --,.,v- ~--r

_ _. ~ - - - .... ~ a s r sc u + 1 l c t A l l ? i l i i j TABLE VII-A-9 J l 4 t I i i l' FORT CALHOUN I RECEPTORS IN ALL SECTORS O2-08-88 i SPECIAL LOCATION # 9 RES i AT 4.99 MILES ESE s SETA AIR DO5E a 5.88E-04 MILLRAOS GAMMA AIR DOSE = 2.63E-04 MILLRADS PATHWAv T.SOOV GI-TRACT DONE KIONEY THVROIO LUNG I - _______.----_____..__________.__________.. LIVER ________.._______.-.__________.____..____.____ SKIN i PLUME l 3.60E l 1.60E-04 l 1.60E-04*l 1.60E-04 1.60 l 1.60E-04 l 1.66E-04 l 4.05E-04 { -_-__-_.--__-__-04 _.._-_-__.---,____--_-__._---_____..l____ E-04-----._-...__--.-_-___--_-.__.._..__ l i 1 GROUND l 4.02E-08 l 4.02E-08 l 4.02E-08 4 l 4.02E-08 l 4.02E-08 l 4.02E l ..-______.__________._--.____..__________.l___.02E-08_______.__________.__--- .--_.---__ ____.l_4.88E-08 rNnAt l l l t -l l l .I ADULY l 2.00E-06 l 2.02E-06 8.60 .________.-__.-_____._________.l______E-07 l 2.84E-06 l 2.34E-06 l ____.-_______.-.-... _____._'4.89E-05 l 1.93E-06 1.1.87E-06 l j TEEN l 2.05E-06 l 2.05E-06 l 9.88E-07 _-___.___._-___ -_...--_-____.- ----_-_-__.l_2 25E-06 l 2.53E-06 l 6.39E-05 l 9.99E-0 __....._,_.--_-___..._____.--_.----__._6 l 1.88E-06 l CHILD l 3.860-06 l 1.75E-06 l 1.02E-06 2 l 2.27E l 7,98E-05 l 1.77E j _________.__________.______...-.__________.l___.03E-06__.___._______-06___._________.._______-06 l 3.66E-06 l NFANT l 1.08E 06 l 9.9tE 07 l 5.35E l 1.30E-06 l 1.36E-06 l 7.30E-05 1 _________._-..______.__________.______-07_.--.-_________.__________.__--_____..l___.03E-06 l 9.55E-07 l l l 4 1 a 2 + i 1 1 i 4 4 l J r l i .VII-16 I i ., _. _. _...., _. ~. .=

_ q 1 1 i a. 4 , ~ TABLE VII-A-10' I i ) I l F OR T CA LHOUN t RECEPTORS IN ALL SECTORS 02-08-88 SPECI AL LOCATION # 10 SEEF { AT 5.08 MILES ESE i BETA AIR DOSE = 4.2tE-04 MILLRaDS GAMMA AIR DOSE = 1.84E-04 MILLRADS PATHwAv T.80DY GI-TRACT B LivtH' MIDNEY THvR LUNG SKIN _________.__________.__________._____OME_____.__________.__________.______OID PLUME l 1.12E-04 l 1.12E-04 l 1.12 l 1. 8 2E -04 l I.12E-04 I t.12E-f,1.16E-04 l 2.86E-04 l _________.__________.__________.______E-04____.__________.__________._______04 MEAT I l i I .07 l 3.63E l 3.03E-06 l 3.49E-07 l 3.49E-07 I I -l I .l ADutT I 3.73E-07 l 3.54E-07 l 8.34E-l 3.57E _________.__________.__________.___-____08__,__________._______-07___.__________.__________ TEEN I 2.24E-07 l 2.stE-07 5 l 2.15E-07 l 2.20E-07 l l 2.08E-07 l 2.08E-07 _____e___.__________.__________.l___50E-08_______... . _____.__________._'2.tSE-06________..__________._____ '} Cntto l 2.73E-07 l 2.53E-01 7 l 2.60E-07 l 2.b6E-07 l 2.52E _________.__________.__________.l___.38E-08_______.__________.__________.1 3.IBE-06__________._______-07 l 2.52E -0 7 l 1 i \\ k l A 1 ~ 1 .i i 5 9 I k 4 l 4 I t VII-17 4

__.m ... - m. m. _.m-- ...~.. - _.. _ ,_m ..._.-.---.---..-m. .m m.. i J i I i ? i ? J TABLE VII-A-11 t ( FORT CALHOUN I RECEPTORS IN ALL SECTORS O2-08-89 $PECIAL LOCATION 8 Il VEG AT 1.30 MILES SE SETA AIR DOSE = 6.70E-03 MILLRAOS GAMesA AIR DOSE a 3.60E-03 MILLRADC PATHWAY T.800Y GI-TRACT BONE LIVER MIDNEY THvROIO LUNG $NIN PLOME l 2.24E-03 l 2.24E-03 l 2.24E-03 l 2.24E-03 l 2.24E-03 l 2.24E-03 l 2.30E-03 l 5.22E-03 l GRouNo l 9.41E-OF l 9.4tE-07 l 9.4tE-07 l 9.41E-OF l 9.41E-07 l 9.4tE-OF l 9,4tE-07 l 1.14E-06 l vEcET l l t l l l l l. I i ADULT l 7.98E-05 l 4.28E-05 l 1.72E-04 1 3.95E-05 l 4.17E-05 l 8.72E-04 l 3.65E-05 l 3.65E-05'l


,.---..----.----------...--------....-------.----------+----------.----------.----------.

TEEN l 9.53E-05 l 4.8FE-05 l 2.13E-04 l 4.46E-05 l 4.66E-05 l 7.38E-04 l 4.18E-05 l 4.'18E-05 l CHIto l i.55E-04 1 7.0tE-05 1 3.54E-04 1 6.84E-05 I 7.09E-05 l 1.15E-03 l 6.47E-05 l 6.4FE-05 l t I t VII-18 i 3 - - ~ - -

1 i \\ i ) 1 l i g TABLE VII-A-12 5 1 FORT CALHOUN RECEPTORS IN ALL SECTORS O2-08-88 i SPECIAL LOCATION 8 32 RES i AT 1.66 MILES SE' l BETA AIR DOSE = 3.63E-03 MILLRAOS GAMMA AIR DO5E = t 87E-03 MILLRAOS 4 PATHMAY T. BODY GI-TRACT 80NE LIVER THVROID LUNG SKIN _________.__________.__________.__________._________..__ KIDNEY PLUME l 1.16E-03 l 1.16E-03 l 1.16E-03 1.16E- _________.__________.______-___.__________.l_______03___.__________... _______.__________.l______E-03 l l 1.16E-03 l 1.36E-03 l 1.19E-03 2.75 2 GROUND l 4.80E-07 1 4.80E-07 1 4.80E-07 4.80E-l 4.80E-07 l 4.80E-07 l 4.80E-07 l 5.83 _________._____.____.__________.__________.l_______OF__,.______.-__.__________._________ ._____E-07 l INHAL l l l l l l l l l ADULT l 1.20E-05 l 1.2tE-05 l 5.64E-06 4 l 1.4tE-05 l 3.14E-04 l 1.15E-05 1 _____.__..______.__________.l___.28E-05_______.__________.__________ __________.l___.ttE-05 l TEEN I 1.23E-05 l i.23E-05 1 6.48E-06 1.36E-l 1.54E-05 l 4.ItE-04 l .19E-05 1.12E- _________.__________.__________.__________.l_______05__ .__________.__________.__________.l._. __05 l 3 CH LD I t.stE-oS l 1.05E-05 1 6.69E-06 1.23 _________.__________.._________.._________.l_____E-05l i.38E-05 l 5.14E-04 l 1.06E-05 l 9.87E-0 l _________.__________._________..________6 INFANT l 6.50E-06 l 5.90E-06 l 3.50E-06 I7 l 8.30E-06 l 4.70E-04 l 6.20E-06 5.68 _________.__________.__________.__________.___.92E-06_______.__________.__________.__________l_ l 1 i f } 1 l 4 1 4 1 i ] VII-19 ii i 1 .----.v-, - -.,... -. - -,. ,em-.---e,--.-,---o--w,-. - -. - -., - -. - - ' - - - - _. -.,., - -. - - -,--,-,--. - - - ~, -,

1- __ - - --.. _ - ~ _ - O O i w k l b t ( l 1 1 a 1 5 i r A i 1 TABLE VII-A 4 .P t l FOR T CALHOUN 1 RECEPTORS IN ALL SECTORS O2-08.HH i SPECIAL LOCATION # 13 8EEF AT 4.74 MILES SE 1 i ( BETA AIR DOSE - 4.18E-04 MILLRADS j GAMMA AIR DOSE = I.79E-04 MILLRAOS i l PATHWAY T.BOOY GI-TRACT B LIVER MIDNEY TH LUNG SKIN {


.----------.----------.--- oNE-----.----------.----------.---~~YROID PLUME I l.09E-04 l 3.09E-04 I

l 1.09E-04 l 1.09E-04 I l 3.83E-04 l 2.80E-04


.----------. ---------.l--.090-04-------,---------- ----------.]--.09E-04-------.---------- ----------.l MEAT I

I I I 1 I I i i ,r i AOutT I a.82E-07 l 3.s4E-or --_------.- --------.----------.i t.20E-Or I a.coE-or l 3.ceE-or _---------.---------.---- -----.1 4;2iE-os i 3.4sE-Or i a;4eE-or l TEEN 2.3:E-or l

2. 2E-or i. 94E-Os

. ---------.....------.t 2. t rE-O r 1 2. 24E -o r I a. o i E -os i 2. osE -o r i

2. os E -o r i.

2'.87E-Or i CHito l 2.53E-Or 1 ---.---...-----.----------.l...06E-Or l 2.64E-Or i 2.77f-07 4


-...-------.....-----.l--.48E-06 l 2.53E-Or j 2.SIE-07

.-- --.---...-- -....------..l l I r 1 i ? 1 i c ,l t' o i l . r l. + I 1 . i t i t I i VII-20 l-i J ( '4* {

7% v +-+-+--+-+-+-+ I I i 6 6 4 ' M 8 @ l @ f @ f @ l @ t 9 00 01 ot oe of o, f 2e a t I i e i i i, y I W I W 1 W 4 W I W l W t "M I @ 8 M i oth j T I T i el @ 8 C. l N. 8 N. G @ l @ f 4

  • I 1

t l e t . e i C O N I M g M t N I - p I t t t t a 3 +-+-+--+-+-+-+ 8 i f 1 t I t I M f @ l @ t @ l @ l @ I 8 ol os oeoiol o4 di e i 4 4 5 t 4 l 1 i e 1 2 1 W # W I W eW s W e W 4 3 0 2 4 M 3 M i @ p A l me M. I M e T. s o. l s e J i @ I e % 1 4 - 4 I - t 3 1 M I N ! M f M4 M i a 4 8 I i i i n +-+-+--+-+-+-+ 8 I i i I 6 6 oS M I @ l T I M I M 9 M l = f oioe ot oeOl oa oI a e i l a e e i e e i a 2 i W l d t W G W I W $ W 4 > f Ol M S elm 4 T l

  • I If h l M. 4 t

M I N. i @ t T I > l - 6 i M I N I @e t I a e a e e= l a aa e a e i e s g +-+-+--,e -+-+-+ 8 9 I i i i 1 eM a@ t @ s@ e@ s@ i > t ol os osol os os w a i t a e e i a e i t i e Z t W rW 6 W sW I W I d i oe O I M t eet M t N e M. e ". d T. e o. i T. = f A l I l i g # . s s l 1 I M t N a Tt T iT N s e a e a e e a T e +-.+h+--+-+-+-+ M b a i I I e f a 8 I M i ci @ t et @ a@ i e eoroe oeosoeos o 2 6 e l s i e e e a e i e e g i W 4 W l W I W f W I W t W e \\ N > l @ l M t N t T I Ql = 8 N c = 9 8 M. e . e@ e@e t t N t e i M. I OV J 8 6 8 e. s w OO I M I N MsM I MI N e m W e 4% t i t 1 4 e s y a a m z. +-+-+--+-+-+-+ m o s e a e 1 4 e a Js I M e@ l @ s@ l @ s@ e 4 V

== t ot ol 08 01 0e on H W II W t e a e a e l a s e a e i e Z i W eW t wl W I WsW t NM osmiM I el T t - l @ a J oc cam. I e l . :. a 3 l M I @ t p1 00

0.
  • J e e s

I v 4 WW G M I N4

  • I a t N i e e r

CE I I I i l i 1 2 oc + -+-+--+-+-+-+ M I i t 4 1 g k I M i @ l @ l @ t @ l @ l V V eoice cl osoeoe 4 m a < s e i e t e a i a e e i t ceW g l WsW t W owaW l W e

  • We WW m i meme ol eeN i oe 43@

Oe 1 I N e M. s T. i @

o. i n. a e

i i w QQ - i e i i.. t V Qo Ql M I N G Mt M 4 Mt =a WTA 1 i e i I e s a=W 32 + -+-+--+-+-+-+ J

== 1 1 1 . @ 1 Al @ t I I e % "I 44 i M I @ l @ 4 eot ol oe osvI of Z 44 D e e i a i t i e a e a t c2

  • ol W l W I W f W 9 W l d t

""Z w ol O O M I @ f @ i N t E l Z(o* C WI C l h. I M t T. t @ I N. i et .Q a l 1 e t 4

  • l 1

i DU k T MI N I MI MI Ml a g i oo e e i e i 1 1 rap +-+-+--+-+-+-+ a < t s n I s e 1 (J D i a i i I t > t V4 4 e I f k 8 8 ol Zi = 3e eoa J 3 a.Z ae i si s: i

  • U Il W t Zl 6 = 1
  • 1 TW

> l 21 39 4oI W t It 21 i C4 < l seot rq am1 W4 m i hM al J e 1 2 a e e i 9 4 1 4 = t 4 4 i l l I l f~' I 1 r

_. ~ _... m.__ -_..._m .p'; ?? ( ' < v.%n..c.

  1. a,-

-1 s ? T' %. ; l 4y'y 4 l . '] -l 4 t i

I I

-l s }, 4 } t + 1 1 1 TABLE VII-A-IS ? 4 ? FORT EALHOUN 1 RECEPTOR $ IN A L*. SECTOR 5 02-08-88 i SPEEIAL LOCA110N a 15 VEG l AT C.90 MILES SSE l SETA AIR DOSE = 1.04E-02 MILLRADS GAMMA AIR DOSE = 5.88E-03 WILLRADS PATHWAV T.80DY GI-TRACY SONE 8(IDNEY THvROIO LUNG. ..--_--____._-liver ____-___.__-__ ____..----...__.-.....___.__ _SdtN 4>LuME l 3.67E-03 l 3.67E-os l 3.67E-oa 3. e. 7 E -03 .__...______..-_-_-___..______.__..l.....----.l.3.67E-03-l_________.___...____.-..__-.___.___----- 3.67E-03 l 3.76E*d3 l 8.39E-03 GRa v> l 2.tBE-06 l 2. tee-06 l 2.18E-06 2.!8E-06 l 2.18E-06 l 2.18E-06 l 2.65E-06 .__...__._______.___.__--_.________--l__________.l.2.18E-06____....._____.___.......__ .._. --_______.i VEGET l l l l l 1 l. 1 I ADutt l .55E-04 l 7.05E-05 l 3.96E-04 6. l 6.8tE-05 l 1.98E-03 l 5.60E-05 5 ____._.....___. ___.____..__..__________.l.. 30E-05_______..... __........._____.___..____..l. 60E-05 l' TEEN l 1.87E-04 l 8.08E-05 l 4.90E-04 7.06 __....l.___ E-05 l 7.54E-05 l 1.67E-03 l 6.48E-05 6.4t .l... 0-05 l EHito l 3.08E-04 l 1.i/E-04 l 8. sac-04 l .osE-04 l-i.34E-04 2.6 ___.._-_______.__________.l.___ce-os l___ __..________.'.________ 9.93E-05 l 9.93E-oS VII-22 -.... - - - - ~

. 2 4) + - + - -. + - + - + t i e I f A M4 @4 @ l @ 4 eot Qt ceoi Zt 4 ( 4 8 1 I e t

    • I W I W 4 W l W f X eOe

@ 4 T I M i d f @ l A i @ t (a j e j . I e e i T T aNiMi 4 I t 6 +-+--+-+ +4 3 1 9 t E I M8 @ d Q l @ l 8 OI Ct C a C, t 0t i e i s i e e Z t ws wewiwi 34 C8 @ l 4 iM i J f

  • I A e n

e t

e. ;i T. e, i N l T 8 N4 Mi e

e i e s + - + - - +. - + - + 3 9 t 4 QsMs 4 s@ s4 i C"

  • O 8 OI Ct Ca i e a i e a i i e 3 3 W l W t W i wI M a N eoeN e II
  • I N t C eM i

> 0. 0 = 5 > e 0 N I

  • 8 C4 m 4 I

I 6 a i + + - + + + i t i I l I N i @ l @ l @ t > ace Q'oeQ wI I i t i e e s i 2I wI W f 6 6 W f OI M i CC 4 T 4 % 4

    • I 88 i M i M. i Qt X 1

= 1 e 8 t

  • 4 i N 0

@ f M i T I i 4 3 t I +w=+-.-- + = = + + P=4 6 5 l ( t j 0 Mi @ t @ l @ l g D eoe ooonos o ae e t e e i s e i m wiW I wewawI g > t M i N I M iN I I M Q

=l se e e g a

3g g MM .J a e 4 . I e e e g M OO I Nf M M,i M i u., a y 2 22 + = = + = = = + - + = = + y C .+ me t l 1 1 8 4 wJ 6M # @ l Qe@a U

=

4 Oe Ct oaoa H w 23 We a e + t i e i t e 2ewa wiweW i MM OsM s M i oe-e CO OI

  • I

@.t T. q N. 4 J t i B e a t t l 4 W tel I NI M1 N l Mi ON i I 4 e i 2

  • T

+ me +-e+==++ = I 6 4 i O @M M i M I @ 4 @ t @ 1 Ul Ql Q 4 C1 Qt 2X 18 01 4 8 4 4 I i 8 I t t Q3W E i W 9 W eW I W 8

  • Oe wW a-i Mi ea@ > oa 44A

@A l 6

  • I

$. I @ s@ l W QQ as a W QQ QI N. g l . t , a I T t N - Mi w@e i t i i i 2=W 22 + = = + - - + = = + - + J

= =

1 s e e s 44 8 Mt @ l @ 6 @ t 1 O Ce oaQaoe Z << > e e a e i a a e i OO >3 OI W i tal 4 wt ws

=

w2 oeM i J a4 t A a C4 C9

  • 4

$I @.I Mt i Z4* Q

  • a e 4
  • I t

3W $= f N4 @ l M $ Tl CO 1 I I I e s> + - +. - +-+ + J 4 I I i i i CJ >8 I I i f ve e a > e L 0t Rs a d s2eJ e

== >U IeW e 3 e w i== l 2w e-e 3 e>ciwi e Oa <e aeg< s>#we b@ 40 d I W I I L f 44 2 0 I 4 i

./ r '{ 1 5 4 l t g i g g g 100 @t @ l@l T t @ l @ l @ f@ l 2,- - eQiQ* OeCice . Q i c e Q i a.. t 29 e 1 8 i e eit i n. 4 i i I t : IW% Wt W t WI W t W l W4 Wt WI "8 E N 6 Qt T tN i k i @ t h ae = t MI St @ 8 Q6@ l Os MI Mi@ t h $ 4*8-

  • I
  • 4
  • I s t
  • 1
  • 6
  • 3
  • g l@ 8 " 4

@ l @t o e MI MINT = l I t i e I 1 e a e + - + - + - - + - e = 4 - - + - + - + -,t T 1 i 1 4 4 3 i e 4 g S M i@ l @ l@t 9 0 @ t @ l @ f@ 6 IQ8Q QtQaof Qt Q8 Q1 0 g i. w...i W. wit Wi W.t -0 i .. I t 6 i t .W. w. W0 W e = Ct ei 4 4N 4 N I @ 6 = t Ql g 3' 34 dl@* 1

  • 4
  • I*e l T I Ol@ l OI T t @ I NI C t 1

a t

  • s
  • l
  • t
  • 6 IMt a l.

@ l@ t e i M4 Mt Me=t I i t I i 6 4 ' 6

  • -+-+==**+==+-+--+4 - + - e=.,

8 I 4 4 4 6 1 4 6 3 08M i @ l' M8 Mf M S T I M t M I M ,g a l Qt Q t QiQt CI Qt Qt Qt c oe 4 a 6 e e i e I e t i t s t i t i t-El W4 W f WlW l W B W 9 W I W 8 W e > 8 T I C 6 A l @ t - 4 Jec# N ama Z#CI T 4 Mi* 4 C4 C# N I @ 6 4 3 > 0

  • 1
  • 1
  • 4
  • (

e 4

  • t 4 1
  • 6
  • g B Mt

= A' =4 m 3 e s @ d =t > 3 = t 1 1 1 1 I t i 1 + - + - + - - + - + - + - - +I -+-+-4 e i t I - 8 L l i t i IM i @ 1 @t @ $T l @ l @ t @f@ t > tQf Ct O4 00 0t CIOaQ0 0t W1 s 5

  • 9 e t I e # 4 4 1 4 s e t i e ZiW I W t W fWeW 4 Wl W4 WfWe Qt T im8 N een>t etcl esT I w l W I T I Gl @ l
  • t Me@ lN f@ t WG
  • 4
  • 1
  • 1
  • t
  • I
  • t
  • 4
  • 1
  • t 4Mt a l

@ th e-t T I T l T I Ns t i I t I 4 6 1 +-+-+==-6=+==+===+-+4==+==,t e E o t 5 4 1 a 4 4 4 4 4 i M 6 @ l @ l @ 8 T l @ l @ l @ 6 @ c I QiQs 08 0006 00 0aQsQt g Q Rt t t e t 4 0 t I e 1 - e I e t i t e a 6 g W eW l W 9 WIW8W 4 W 1 W I WG W t N >0 T i S f N a@ lM I Ol MI Mt N I 8 o m i el T t @+ Me=* @8 4 = sk t T eM-Jt e t e t +3 e s e t

  • t e l a t 0

QQ SMt

  • 8

@ B N f a l Mi teMcNt' N e 4 m W 44 I e i t 4 s t i 4 1 4==+==+====+-+==e===e+i 1' e.*e g 22 -e**=+==*+ y Q JJ t I 8 I I t t a t I g JJ 4M8 @ 4 T I Tt T e @ 4 @ t @t @ l w W W

== I Qf QI OfQl Q4 QeCI OtQt W E3 WI 8 i a I e I e i e e a 1

  • t a t i t J

M 2I W I W I W IW I W s W# W 3 W6Ws Q NM Qe9 aet Qs@ e@ l Ot @ t Mie e J QQ et e: T s N #Mi@ t E t O6 = a=a H J e a t a t a t e t 3 1

  • t

+1

  • a e t e t I

4 ud IMi*4 NIMi@ 4

  • I NI N0 = 1 NG E

B e t i + - + - + - - + - + -.I - -.t ~,t -,t-.t z mQ i t t t t t t t 4 4 W kIM4 @$ @ l @ lT I @ l @ 4 @ t @l M) UtQtQI Q1 00 00 Cl Qt QlCt E o at 4 1 4 8 e I e 4 4 4 a e 4 4 e 4 s I t 6 QM E lWI W8 Wt Wt W t W l W4 W1W I kW WW ktT 1 86 Ml a t @ 4 @ 4 N e@ f @ t aEM MM B 191 T 9 Q$Qf e l @ I N ew 8 N 4 W QQ m t a t e t

  • t
  • t
  • t o n e t a t
  • t U

QQ QlMl a 9 M 4 Gl

  • I Mt M4 Mt
  • I Wad 4

e i i l i i e 4 9 E W EE e==4-+===+==+==+====$=+==+==+ J wm ' I t 0 9 i t t t I i %= (( SM i@ l TI T4 T 4 @ l @ t @4 @ t a eQiQ. CloiQi Qio Q Oe a << > e.... i i n t. i i i f i. i t i QN >3 Ot W I W 8 Wt W6 W f WI W9 W 8W4 s mwh WI Q5 9 t ei Mt MI @ $ M t N i c4 N t j S4 8995 T l N4@t T 4 @I N I Mi@ t EqQ Q

  • n
  • 1 **
  • )

l e t a t

  • 6
  • 1 e t e

DU MtMl a 8

  • 4a l N4 M8 Mt Mt a l OO i

8 i 8 4 4 6 6 6 Idw + - + - + - - + - + - +4 --+-+-+-+ J ( 4 1 1 l i l i i n 4J D I 4 8 4 4 4 6 4 l > t W4 4 e a a et Qt t Ot 2i = 3e t oe J8 Zeat 46 El st 4i ku Il W t Z#N24W e=I JOI W e=t ma SW k0 38 Qf WOfW t Z4(QtW t Zl El Q& 4 131 QS O4 8k l WI I4 4 > 6ut=8 kV &I d aqiW 9 4 4 2 I I t i 144 Ot > t i I m 8 0 4 4 l l l i l f

4 2

-+--.-.-.

!~'s: i v. ~ z'?l ?! .lo; -iwi I 'b8 Ol M eM t m, @*, M. g, l ,3 I

  • 8
=.

e,. o. e, + -., - -., -., -., ie. ~,s ~, e;*; *: ?:o-5lW! X W;i,l sie. - e.in,,

n.-+--

.. e,, i 1 a;w; c: c;o: o;?; ?l? *: ='w-wiw.m. D ' e" 8 o4 T t M nni .,,~.,,~.,,e .-v - -., -., -., i ~, ~, ~, 0;?

  • : o

.to: z>w w o.- e 2 '. : '. . ; o: ~ ' n. e. -.a e,, c, _, I i ~,. W 'T 8 ~s ,'f,' pao,~, w a c, N Q g M w a:a a -iwi $!5! $j@l4: E: E me oo

n;
    • c, m

a 8 ~,s: c -s ~ if m: l o;o weal'a! oi =" g;r; Rl*!2l e, oo o;dj dl4:4l M4 3 . e. -c ~se! 'n; ~ ~ v o;

o..s o. i o,,,

es om $,ljl W W owa o'nio. ~w mm

==e me ".' T ' c ' WN ta o g o= l, O l t gg ~;~;~; g l?: o oio. 2 8 0 1 8,' r ; $ ;; s.,!

  • l z

4la! z;- 5 3

a. ; '. ;

es au 0 0 ,I 08 e4 5 4 QQ"; 9 3 <a I I I W4 q g 8 b i t Oe = f,'wi

  • g:J I

' = 0 a m, = ,I ~U I I I 8 W 4 I6 Qg 4 8 38 4( a ~,s y, mm & 4 - 6 W g I b i r t g y i I (

-~,-. . - - - _. - - -. ~ -. - -.. ~. - ~.. -.. .- -.,~. - - .. ?r. ~ s 3 q. I 4 + 0 1 i l i TABLE VII-A-19 I i t l FORT CALHOUN 1 , RECEPTOR 5 IN ALL SECTORS O2-08-86 ..l SPECIAL LOCATION # 3 cow.PORM j AT 2.74 MILES 5 n ) BETA AIR DOSE = 5.48E-04 MILLR405 GAMMA AIN 005E

  • 2.57E-04 MILLRADS

+ PATHwAv T.800V GI-TRACT SONE LIVER MIDNEY THvROIO LONG SMIN [ t j PLUME l 9.5 7E -04 1 3.57E-04 l 3.57E-04 l 1.570-04 l 1.57E-04 l 8.570-04 1.62E-04 7 ........_..-....____......____._____.--...._____-..._~___._.......______.l____...._13.89E-04-l i MEAT l l l l l l l l { l j ADULT l 4.89E-07 l 4.53E-07 l 1.52E-07 l 4.60E-07 l 4.7tE-07 l 5.33E-06 1 4.45E-07 4 l .._____-_._......__.. - -.._.__________.___.______.__________.__ ___.._.__________.l___.45E-07 1 TEEN l 2.95E-07 l 2.71E-07 l 9.99E-08 l 2.78E-07 l 2.87E-07 l 3. HOE-06 2.66E-07 l _______.l ___-_-__.l.2.66E-07 CHILD l 3.60E-07 l 3.24E-07 l 3.34E-07 l 3.37E-07 1 3.47E-07 l 5.66E-06 3.2tE-l 3.2tE-07 l p ___...___.____........_______.____ _____.____.__.-._.._______..________..l 07.__.._________. (Ow mILu ! - 1 l l l l 1 I. I Aoutt i s.27E-06 I s,s5E-06 l 5.66E-07 l i.30E-06 I a.47E-06 l 7.49E.05 I i.05E-06 _______.....________...__.___.-..____...__...________.__-........ ____.--_..__________.1.05E-06 1 TEEN l 3.72E-06 l i.5 E 8.68E-07 I s.8st-06 l 2.13E-06 l 3.19E-04 l 1.36E-06 l 1.36E-06 _______06 l___....____....___.........-_____... ______--_..__....___._____......l ) CHILD l 2.81E-06 l 2.28E-06 l 1.69E-06 l 2.93E-06 8 3.43E-06 l 2.38E-04 l -_..___....-__..___...__._.---.____..-.....-_..._..._-._____._____.-_-_-.l.2.85E-06 l 2.tSE-06 l I INrANT l 4.3:E-06 l 3.39E-06 l 2.59E-06 l 5.17E-06 I 5.49E-06 l 5.77E-04 1 3.27E-06 l .......___.._._.__.....____-___-.._..._. _............---_...._.___ __....1 3.27E-06 4 4 1 1 t 1 ? I t k 4 i, ) VII-26 4-e-e- -.e w..sm e w,--e-e-s_e,w.--s.m.-w.-e=<-.e-r._-- .r-ee-,u e - se a c=-r-vee. 2+-.w,-- m.4mr r+ ve ---e-.% w -c..,.n e-em. ww-- e---- -,,-. w w wwe.,e--.wr

s f ( ). ..~ (y \\d \\j TABLE VII-A-20 FORT EALHOUN t REC [ PIONS IN ALL SECTOR 5 02-08-86 SPECIAL LOCATION a 4 RES.VEG AT 0.63 MILES $5w BETA AIR DOSE = 5.85E-G3 MILLRADS GAMMA AIR DOSE = 3.32E-03 MILLRADS PATHWAV T.BOOV GI-TRACT DONE LIVER M .__._----_____.________-_.__________.--_-______.____IDh[Y THVROID LUNG SKIN PL UME l 2.07E-03 l 2.07E-03 l 2.07E-03 l 2.07f-03 _________.__________.__________.__________.__________.l__2.07t-03________..._-_-____.__ -______.______.___.l l 2.07E-03 l 2.12E-03 1 4.720-03 GPoVND l 9.27E-07 l 9.27E-07 l 9.27E-07 l 9.27E-07 l 9.27E-07 l 9.27E-07 l 1.83E l _-__.___..__________.-_________._________.______-___.l_9.27t-07__-______,_______---.-___._-__...______-06 vct.E r l l l 1 l l l l l A09LT l 7.36E-05 l 3.75E-05 l 1.68E-04 l 3.43E-05 l a.49E-04 1 3.13E-05 l 3.13C-05 _________.__________.__________.________...__________.l_3.65E-05_____-___.__________. .._______.__________.l T r e.N l e.etE-e5 l 4.27r.-05 1 2.osE-04 l 3.87E-o l 4.07E-oS l 7.taE-04 l 3.59t-05 1 3.59c-05 _________.__________.__________.__________.________S--.-_________.__________.__________.____ CHsLo l 1.440 l 6.09E-05 i J.45E-04 l 5.93E-05 1 6.tJE-0 ___-_-._-____-04____._________-.___-__...._-__.____..._______5 l 1.12E-03 l 5.50E-05 I 5.56E-05 1 __._________-.-_________ _____~____. INHAL l l l l l l l l j AouLt l i.enE-05 l 1.90E-05 l 9.43E-06 2.02 l 2.24E-05 l 5.86E-04 l 1.HtE-05 l 1 74E-05 _________.__________.__________.__________l______E-05____._____.____._________.._____ 1EEN l 1.93E-05 l 1.93E-05 l 1.08E-05 2.15 2.44r-05 l 6.76E-04 l 1,88E-05 l 8.75E-05 --__.____.__________.__.-._____._________-.l_____E-Osl____.._______._. __________.__________.l EHILD l 1.76E-05 l 1.64E-05 l 1.12E-05 1.94 ______-__.______-___._____.____.____--____.l_____E-05 1 2.200-05 l 8.47E-04 l 1.66E-05 l 1.55E-05 I INFANT l 1.02E l 9.27E-06 l 5.82E-06 l 1.26E-05 l ?.32E-l 7.75E-04 l 9.76E-06 l 8.89E-06 _________.______-05____.__________.______--__.__________._______05__..._______-__...-_____ __________,l VII-27

\\ +==+=====+==+6 8 I -@l@t 4 0 0 e i f9 t Io6 o a o e o@ s 20 4 0 4 i e a e e ='* I W 4 W8W5 W G W4SI .N 4== t @ l M444 M4@t = 4 -4 4 4 .t 4 I Te T eNaMe ++-.=+a 1 0 I t 5 + f f I a t iM$ 'o@eoa l @4 Ioe o' a Ql e i I ' e e s e 2iWl WI Wt led 4 j. oe@ l ~l p ef) g W l o. e M.i @ t.e.4 I 4 'l 8 Nf T I N t t'4 e 4 4 a e ,8 -,8 -+ e 1 1 4 I i Oemi @ s@ s t i =eoe o e o e o@ 4 i Oe e e e e a a e-e. 2O Wt W $ W 4 eJ l >0 oI @ l *= 1 mi j I 6 o. 4 @ 8 N. se N. i r se e .I N G gl @ t $.e i t o +.==+=====-6==+=4 e f 0 4 4 IM( @ l@ l@ t a > 0oa oioeoe S' - W 8 e t i i e a i 1 2 8 is1 I W4W l W 4 .o 4 o4 o6.D # Qa i

  • 1 o. 9
5. 41 @6.34 d

1 5 I 6 t g i NI tin 3 Mp b r I

  • 4 e

e O twowmememe C 6 e t t g 4 8 SMs @ t @a s { to4 o e o a o@ N I e w.e o 5e e e a 6 e 4 4 a N e } WfWe W f WI q.J f I p N Dlot N t = tN t we 3' o s c. s e e. s T i e M MM .a # i W .t t

  • t oo fNt T4NI MI i,

J M at 4 8 I e 4 S 3 EE e=9==e=+=,i j. ' aC o .d.A 4 4 4 6 s g r s.a aMe @t @ t @ s W

= =

tCe onono) y W 33 W i e I s 3 e 3 a a M 2iWe WO WsW a MM osos Mime,a a .J oO $ 8 o. a @s@#Ns j' .a e a s .e ,a ( WW aN N 4.= a e 's a e-s e e 1 2 a @ N. +=e====+===+.-+ 8 4 n a e t 1 @ f4 9= tMi @ l @0@ t W usos o e o e o. t e I, gWI w aa < a e a i e e a ElW4 W5W9W 9 j

  • WM W IAJ

> 8oe t@t o6 .= 480 MM w gg .s. 4 04 ..s @ t h. i e 4 V QQ ($ 8 N 9 TI N4 f4 9 W@M t t 4 t E W RE +==,t v .--+ +-e i ed o'.= 4 4 6 i e 44 4 f*) I @ 4@ l@ l 3 eoe oeoeoa E 44 >e e i s ee a a e 09 >S 1 4e a W 4WIW4

== @ ,4 40* WE eoe ea@ soa h* S4 8 oe o.4 o e e I 0 t e t t t d V k6 N4 @4MnMf 4 O 4 3 6 i + =,a }

  • s>

--+-+-+ d 4 l E .I 1 8 <a i 1 t, W4 41 9 >I edB

  • =

1 4 J0 28 .J l >U $ ate 6 3iW i== 1 i Ea 4.0 5t W WQBW . << i m.f 0' f. mM sis.W i 4 4 &4 3 4 9 5 4 9 s

.-s-- V' w 8 J ~ I TABLE VII-A-22 L e FORT CALHOUN $ RECEPTORS IN ALL SECTORS O2-08-88 t SPFCIAL LOCATION s 6 RES.vEG AT O.73 MILES Sw SETA AIR DO5E = 2.8tE-03 MILLRADS GA MMA AIR DO5E = 1.590-03 MILLRADS - ? PATHwAv T.90DV GI-TRACT BONE LIVER M I DNE Y. lHvR LUNG SKIN ' 'E ..--.--..........--...---------.--....---.....-----....----.- -....-- Oto e PLUME l 9.89E-04 l 9.89E-04 1 9.89E-04 l 9.89E-04 .....--..--..... --..---------.---------..--. ------.1 9.89E-04..------...................---.............l l 9.89E-04 l l.0tE-03 1 2.26E-03 GnouNo 1 5.34t-or l 5.34E-or ! 5.34E-or 1 5.34E-or 1 5.34E-07 5.34E-oi l 5.34E-or l 6.49E-or l ........... -..--...-----...-... -----.......------..---------.i --...__.. ---...-.. -_-------.. vrGET l l t i i i i I I Aouti I 3.94E-05 l i.86E-05 l 9.69E-05 l 1.68E-05 l 1.80E-05 4 ..--.......---------.----------.---.------.--.-------........---.l--.86E-04 l _t.50E-05 j t.50E-05 I TEEN I 4.73E-05 l 2.ttE-05 l 1.88E-05 l 2.00E-05 l 4.10E-04 l 1.72E-05 l ---....--.-.----........----.--.It.20E-04----------..---------......----..--....--....------..l.-.F20-05'l cHILo l 7.77E.os 1 2.97E-05 I t.99E-04 I 2.88E-05 l 3.02E-05 ...--..--.----------.-------....----.--........---.......------,l.6.39E-04 l 2.6TE-05 l 2.6FE-05 I INHAL l l l I l 1 l l ADULT l 9.03E-06 l 9.09E-06 l 4.48E-06 l 9.70E-06 l 3.07E-0 __-------._......--._------_-......----_....---._---.-_-.-.5 l 2.46E-04.l 8.68E-06 I 8.33E-06 1 TEEN l 9.27E-06 l 9.26E-06 1 5.14E-06 l 1.03E-05 t.97E-0


._---._---------.-_---...............--.......l....---5 l 3.23E-04 l H.99E-06 l 8.38E-06 l cHILo l 8.4tE-06 1 1.87E-06 1 5.3tE-06 l 9.29t-06

.t.05E- ..-------........---.--.....---.....--......--..-.....l...... 05 1 4.o4E-04 i r.95E-o6 l 7.4st-os,I INFANT l 4.9tE-06 l 4.44E-06 l 2.77E-06 1 b,03E-06 6.33E-0 -..--........----.-.....l.--- -- 6 l 3.10E-04 l 4.08E-06 l 4.26E-06 l VII-29

TABLE VII-A-23 FORT CALHOUN I RECEPTORS IN ALL SECTORS O2-08-88 SPECIAL LOCATION a 7 BEEF. PORK AT O.82 MILES Sw SETA AIR DOSE = 2.09E-03 MILLRADS GAMMA AIR DOSE = 1.25E-03 s!LLRAOS PATHuAY T.800Y GI-TRACT SONE LIVER KIDN ._______........______....._--___.....______.._____EY THYROIO LONG SMIN PLUuE l 7.80E-04 l 7.60E l 7.80E-04 l 7.80E-04 l 7.80E-04 l 7.80E-04 l 7.99E-04 1 7 l- _._-___._._____......__..___-04__.._____-._....___.___.__.._-___._____--.______._..l--,5E-03 MEAT I i 1 1 1 I i l l ADULT l 1.90E-06 l 1.64E-06 l 1.09E-06 l 1.69E-06 1.77E- ..___._..____.-__....__.... _..__ ____..._____...__.l_____ _06 l 3.68E-05 l 1.59E-06 3 1.59E-06 l TEEN l 1.16E-06 l 9.82E-07 l 7.16E-07 l 1.03E-06 1 ______.... _________...____ ___._____._... ___._____.l___.TOE-06 ..l'2.65E-05...._......_._____-07 l 9.47E-07 l l 9.47E CHILD l 3.42E-06 l 1.87E-06-l 9.6tE-07 l 1.26E-06 l 8 _._..____ ________ -. _-...___.._ _______.... __.___._-_.33E-06 l 3.96E-05 l't.14E-06 l 1.94E-06 l O VII-30~

1 1 l i [ i \\ / %) +-+-+--+-+-+--+-+-+-+ b i 4 4 4 I 8 3 4 f I T t h i @ l @ 4 N4 @ l @ l @ l @ l l 2.ot ot olO4 on Osol Ql os 4 i 4 4 4 4 9 1 6 t t I a i e 1 0 1 M l WO W R Wl W I W 1 W 4 W I W I W t W i et O I @ t et Mi N t @ l vt ot M4 T I G l MtNI = 4 @ t @ l a l @ 3 0 G SS N' l

  • 4 a l i l 6

+ 1 - l i @t N l = 1 M I M4 Miae l I I I e 5 4 6 s I f + - + - + - - + - +1 -+--+.=+-+-+ t t i e i e i e i f T t A t @ l @ l @ l @ l @ l @ l @ l 8 08 Of 01 Q1 01 Q'CI CI Oi di a a i l l a l i s t e i e s I a e s 20 W O W e wl uiW S W i W sW .W s Devl oe @ e aaM i % e on@ l ze J I NI M. 4 M. S N t = 0 @ 8 Cf M. i $e t = s s t

  • s

.l . i - 1 I T I N 6 @ I N G = l M 3 M I M e = e i 1 0 4 e 4 + - + - + - - + - + - +4 --+-+-+ ,e B 4 I l 1 i 1 4 6 i OS T l N a vit s T a T I T s T e Te =

  • Q1 0t cl ot os oece ol or Of I s e s e i e i l i i e i e i i e al W l W S WIW I W s W I W I

> t M I ol ot A s@ s ml @ t W ,4 o ,I W i t - I M. s = l h a k I ol M.e @ u @ s > s .l .I . i. e e t T I NG NI = f NQ = l a e = 4 = a 8 I s I l t i e +==+ans. +===s= + - + - + --+m. +-.+..,i 4 D 6 4 4 4 1 e i l S T t h l @ i @ i @ l @ l 4t @ 4 @ t bl Qf C6 Ql OI C4 O I C, t Ql Cs W 1 t t I t t 4 6 l i t a # 3 3 1 r Z 4 Wl W I W I W 4 W 1 W l W t w i W I O$ MI Qt T I N t @ l N e 9 : 4 e N i m 4 = t Mt @l T # N I @ l @ a T e @. 4 e

  • 1 e t
  • a + e 8 %

= t = 4

  • g a e I TI N I N t @ s = t T

viviN I t 8 4 I 4 1 1 4 2 + - + - + = = + - +i -+==+-+-+-+ C i 1 I 1 l t i e 4 8 I T 4 h 4 @ l @ t @ t @ a @ t @ i @ l Y l oI @e Ot ol oe ol CI OeQ* Q Q$ i a i l i t i I 4 4 6 5 4 6 b 4 ' W 4 W 4 Wt W I W S W l W 4 W t W 8 W e a e I I N > I M l On ( Q = I m l N I C i v*N I T 1 M e*L Mt e l @ l N I e t M f @ l @ l m g dM J4 e l / N w CC eT l N+ 4 + 4

  • 1 a t

+ 1 = 3 g a 6sN I = a T e T I M eN i i { d 44 4 6 1 e i i e f 6 3 24 + - + - + - - +l -,/ 0 as t i I l a a 6 I s M -+-+--+=+-+-+ W wa t vt N G @ l @ i @ s @ l @ # Sice W U

== 5 04 C8 05 0t 01 oeot ot os W W 32 W f 8 i e 1 4 I t l l t I e a 1 1 1 1 1 Q 20 W I W I W t W B W I W I W rW # W I q MT OsMi ol el ml et @ s M eol @ s g J CO Cl - I M. 4 O - l a s@ t cl a l N s=t J l a 1 e t a l e l a l I = 1 e t e l WW G TI NS T1 @ l WI = I N I N I

  • I ET f

4 8 4 4 1 6 1 0 =Q + - + - + - - + - + - +5 2 =@

==+-+-+-+ 1 4 l l I i I t I t W =@

  • eT 4 8 4

@ l @ s@ i @ i @ aci@ l M> W4 Qt QB Q4 OeQS C0 Qf Q1 Qt a e

  1. n 4 e i e i t a 4 i l I

e i e I e 1 1 6 QM3 E l W t W 4 W l W l W S W 4 W4 W 8 W l >WA WW W I M I Oi Ol ea@ t 9 8 = I M t el 4E3 MM l la t M S @ l @ i N I Cl @ W Q M i = I e l e l + 1 a l o I + l MI C S W O dl T I NI k l @ l = I M l M S M l a i t

  • t a f WWO I

t 9 i e I + e i E W E% +=+===+====+-+==+i = = = = + = = + = = + = = = + W

== I 4 1 4 9 4 4 5 %= 44 S T l h I @ l dl @ l @ l @ l @ l @ t 3 406 04 0801 00 Ot ol ot cl 2 44 b i l l e 1 i l e t # 1 a t I ( l 4 s L C= >3 Cl Wl W I Wlw*W I W I W I W 1 W I

==Q W3 OtMiot @ l M l MI N eN S @ #

  • s C4 Cl = t M 1

@ l OI M l C l @l @ l ot 2(= d e l a l a t e t

  • l
  • 4 e l a t

+ t + 4 W k l 4 I NI = S N O MB M I M I MI NI O 1 I t I 4 4 l 6 9 . a> + - + - + - - + - +l -+--+-+-+-+ a 4 4 6 ) i i 1 I i I ( J bl 4 1 4 I l I a l > l W4 4 0 e 8 k l l ot el 8 08 Z t ~ Re t os al 2'Jn J e 2e kW Il W # 2e>31 W l = 4 436 W 6 = l a l 4 5 MW el 20 31 WOf W L ZI MOI W I Zt ZI a Ca ( I stol@< lel WeI4 I r l We=0 se &eW saaw e 4 az 6 ) a s sal Qt > I 4 i= 1 1 6 8 5 ( l r v i l

~. _ l s s (. E +== 4===e=9== 0== + 6 e f < 0 4 sTI P* 49eh e 8 oe oeoeQI E8 8 4 8 4 e e e 4 8'e tW0 taJ t inJ a W t W4 9i M4= a% 4 Mt@.t @ I h t = f 4 t e 0 e e a e 4 = 4 =0 @ 6*1 1 4' 4 4 4 4 +==4====4===+==4 0 4 4 4 t $@ t Pm 9 9 i #m i a Cl CtOt Ot l$ 6 6 4 e i e 6 + s IW 4 W 4 W 6 isJ $

Sie, Mi =

.J i me W e P..e h e w i t e I e a e t

  • a f $4 s* 4@9

= I I 4 4 t 4 6== 4==== +=== + mm 6 0 t 9 4 4 O I t/l i @4@$@l

== t ce oeoaoe oee a e ea 6 a t E I 46J t WtW f Wt > 0@ t @f

a a

t It @ 4 Q6N4M4 > I e 0 e i e f a g 4@t ti i N4 ti 0 i I e t t 4== 4 a==== 4== 0 e= 4 8 4 e p 3 4@ 4 h 4 P= 4A L > aOa - OeQ#Qt tsJ P e il 4 1 6 I e t $ 1 teJ ' idJ $ W t Wl G# @ ii et O8 P1 6 ee $@ 1 P. p=3 Mg Wt * $

  • 1
  • I e t i @t
  • t = 1 *0 1,()

f I t e +==**===e==e==,i N e t e f e d I@ t P= s t t -i >= a P= 1 W tOI C >QeOe N i O Et t i e a 6 e i g W 4 he i itJ $ leJ i isJ d W 8 0 W N > 0 $$ NI T 4 P. g Q e=e ed 8@ t k I O0N I MM .) 4 N e 8 =4 e 4 e i y QQ l@ 8 = 4 = t = 4 p M A 44 0 0 4 I 6 O { EE +-+==4-t=4 %J ed oJ t i 9 t 8

  • C
  • =

-J.s e@ t eee4 ee t= U a=== 4 06 C6Ot Oe tad 33 InJ l I 6 e f e t 4 4 M 4 W 4 WI Ind 8 W6 99 8@ 4 T 4 ** t Qt .J CC 4@ t C4@ I O4 s e 6 6 4 e t

  • 4 e 4 4

inJ leJ t@ $ @4@ ag4 hS I 8 4 e I Co +==+*===+e-.e==+4 =

  • =

6 s 6 a t t N e= >e@ e *= 4 P= 6 P. e l' M usoa C408Qs 5L ea ee e e a es ee e QWB E4WI WeW( W l

  • WM WW

>s@ a e9 oa@ s &GB MM i e@ l @tQt a= 1 the QQ -e 6 e i e e e e e e l W QQ Ot@ t = a=e=6 WSM 6 6 4 0 0 l E W EE

  • = = + - = = = + = = * = =
  • 4
      • e 6

5 6 0 6 %== 44 8@ l N 4h a P= t 3 9 oe oI

  • soe T

4 >0 i 6 6. a e e e r QC t= 0 inJ t Wt taJ e ned 6 l laJ. 4

=

I@ @ t.t t =,i 4 ) - e e i @ 9 i 4N d e 6 e t e e a t = t W >0 $6 e= 4

  • 6

= t I O 4 i 1 e I [ .e>= 6.==4=====*==6==+ s. I i i i ..J t i W4 44 6 De i I Q4

== B6 0 J6 26.J 6 >U Zl 4 34W 4 *= 4 EW >= 4 I t=04W t It 04 < s e<<t> sWe es. M & i =d t 4 0 0 6&4 8 5 a 1

i-I, ~~q z t .) - ' (.,) i i i i f s 4 .I ) TABLE VII-A-26 i I 4 FORT CALHOUN I RECEPTDRS IN ALL SECTORS 02-08-88 SPECIAL LOCATION a to RES.VEG AT 3.17 MILES w + BETA AIR DO5E j 1.50E-03 MILLRA05 = GAMMA AIN 005E = 8.93E-04 MILLRA05 \\ pathway T 500v GI. TRACT S LIVER K10NEY THv2 LONG SKIN ..__.........__...._._........._. _ONE.........___......-. __....__.--_01D Ptume l 5.59E-04 l 5.59E-04 5 l 5.59E-04 l 5.59E-04 l 5.59 l 5.72E-04'l 9.25E-03 l ...--_........_....l.. 59E-04_.......~__....-...___.__....._.- E-04 cROun0 l 2.5tE l 2.5tE-07 l 2.5tE-OF l 2.5sE-07 ..._____-07__..__.. .....-............__....l.2.5tt-07...__......-_.. ______.l.3.06E-OF l l 2.5IE-07 l 2.5 t E -0 7 vEGET l i j l l l l l ADutt l 1.93E-05 l 9.57E-06 4 I 8.72E-06 I 9.30E-06 2.2 l 7.9tE-06 l 7.9tE-06 _. ______.___.______._...____..l___.52E-OS....___. .._...........___..l... 9E-04..._......__..._...__........l TEEN I 2.3tE-05 l 1.09E-05 l 5.60E-l 9.80E-06 l 1.03E-OS

  • 1,93E-04

............._.___....__..___......_ 05__.............__...--__. ___......l_9.05E-06 l 9.05E-06 ! CHILD l 3.79E-05 l 1.54E-05 9 l 9.50E-05 l 1.57E-05 3.01 l-8.40E-05 l 1.40E-05 _...--...._......_-_..... _.....l._ 28E-05._____-.-_..__............_...l.....E-04............................l INnat l l l l I l 'l l l A0utt l 4.74E-Os 1 4.7sE-06 2 l 5.IOE-06 l 5.63E-Os i 1.2ee-04 l 4.3eE-06 l .................-_...__........l...,.2sE-uo -__.._......_.......__...._._..........l 4.56E-06 TEEN l 4.s7E-06 8 4.s7E-06 2 l 5.40E-06 I 6.e4E-06 l 1.6sE- ......_.. _..........____.__..l.. 62E-06........._..___ __.___....____04 l 4.72E-06 l 4.4tE-06 l CHIto j 4.42E-06 l 4.94E 06 .._............. _............l.2.7tE-06 l 4.88E-06 l 5.53E-06 l...._....__........_....._.. __.IIE-04 2 l 4.l?E-06 l 3.90E-06 ___.....................____..l INFANT l 2.58E-06 l 2.34E-06 t ..........................___ _.l.. 42E-06 l 3.tFE-06 l 3.32E-06 1.9 __..............._......-___-_.l....3E-04 l 2.45E-06 l.2.24E-06 j VII-33 n---

m_ i D O O i t', 4 i I i d. l i TABLE VII-A-27 F OR T C A LHouN 3 RECEPTORS IN ALL SECTORS 02-08-88 SPECIAL LOCATION # st SEEF AT 2.06 MILES w BETA AIR DO5E e 4.23E-04 MILLRADS GAMMA AIR DOSE = 2.29E-04 MILLRAOS PATHuay T.800V GI-TRACT SONE LivtR MIONEY THve010 5' 1 N _._...___....___........___.____._.__..__..__.____ ____..._ LUNG W Ptumt I t.42E-04 1 1.42E-04 l 1.42E-04 1.42E .._......._.......__...__.__.__.__..__.._..l__...__-04 l 1.42E _..._-____-04 l 9.42E-04 l 9.46E-04 l 3.3tE-04 l 3 v MEAT l l l l l l l l l Aouti l 3.77E-OF l 3.39E-07 l t.62E-07 l 3.47E-OF l 5.57E-08 l 3.35E-07 l 3.3tE-07 J .________.__...___.........___.._________...__.______.l.3.5HE-07_...___..._....__...__________......___ IEEN I 2.28E-07 l 2.03E-07 l 1.0FE-07 2.10E l 2.20E-07 l 3.99E-04 I t.97E-07 l 1.9FE-07 +l _.....___....______....______..___. ___..l.._____-07__.._. ___..._.___ ___..... ___............._...l cH LO l 2.s0E-Or i 2.42t-O r I t.43E-Or i 2.5st-O r _.._____._-__. __.....___.....___.....______.._..i 2.6iE-Oi l 5.stE-us i 2.3eE-Or 1 2.asE-07 ..____........._,,....._-___...._.._____..l VII-34

4 1 i a a I, i l i f L 1 TABLE VII-A-28 FORT CALHOUN 1 RECEPTORS IN ALL SECTORS 02-08-88 SPECIAL LOCATION a 12 RES AT t.98 MILES WNw SETA AIR DOSE = 1.24E-03 mILLRA05 GAameA AIR DOSE = 6.57E-04 MILLRADS PATuwAV T.600v Gl_ TRACT SONE LivtR MIONEY THvROID LUNG SMIN PLuest l 4.07E-04 1 4.07E-04 l 4.07E-04 l 4.07E-04 1 4.07E-04 I 4.07E-04 l 4.18E-04 l 9.56E-04 l GROUND l 9.55E-07 l 1.55E-07 l 1.55E-07 l 1.55E-07 l t.55E-07 l 1.55E-07 l 1.55E-07 I t.89E-07 i INHAL I I I I I I I I I A0uti I 4.06E-06 1 4.09E-06 l 1,89E-06 I 4.36E-06 l 4.80E-06 l-1.06E-04 l 3.9tE-06 1 3.77E-06 l TEtN I 4.17E-06 l 4.17E-06 I 2.98E-06 I 4.6sE-06 l S.22E-06 l 9.39E-04 I 4.04E-06 l 3.79E-06 l Cu Lo I 3.78E-06 1 3.55E-06 l 2.2sE-06 1 4.tGE-06 1 4.69E-06 l 1.74E-04 1 3.58E-06 l 3.35E-06 l INFANT l 2.2tE-06 l 2.00E-06 l 1.18E-06 1 2.69E-06 l 2.82E-06 l t.60E-04 1 2.50E-06 3.93E-06 ____.____.__________._________.._____.____...____ ___,______..__.____._____......__...) ___....__.l VII-35

y,___ 1 b t. -I . ( b\\ t I I +=+-+--+-+-+ -+-+=+-+. e d i I 4 5 6 4 1 9th e @t @s@4 @ t @ 4 @ eOs e J tot Qt Q4 0 eon oaoeceos j Zl i a e 6 - a t a e e 6 e i 6 e 1 ie a .t

== 8 W eW 6 W t WaWt - WtW eweWt KIN t m t-Ot @ lNS etct h aNo 'i @ 4a l M. t 4 N e@ 4 N. 6 e @ l @ 4 M. 4 .I t es = e t e t 6 R h 9 " 5 @ 4 @l @t MtV. e i t h l = g I i 1 4 t i . 6 I e + - + - + = = + - + = $ - = + = + = + - +3 'f 4 6 4 4 4 4 1 1 1 1 1 9 9 A 4 - @ t @f @ l' @ l @ $@4 @t 5 4Q0 06 Q1 09 00 Q4 Qt @ l O4 Ql 4 0 e 4 4 1 4 6 4 S t i b i e t 4 I 5 4 9 Wt W t W t W ( Wi W4 W I W4 We 'f Dim 4 T 4 Qt @ t N S e4@ 6 N 4 Ne Ji m t e i Ni@ ? NI @ l@ t MI = 0 6 4 4 0

  • I
  • q
  • t
  • I

. 6 e i M e.e i t s e.a t @ a@sma Meg eh i e t I ( 4 1 e a e -+-+=+--+-+-+==+-+-+-+ t t 4 8 4 4 + 4 4 Oi90 A 8 9 e@ 8 9e v8 weM sMs f =e01 08 Os O8 08 08 O8 0*04 i Os e e # 4 4 1 4 e i i s t i t e +e e i a6WI W e W8W8 Wt W tW tW6 WD -f D eMag a N t ot N4 9 eot N t % t Isot = a Cia eve seoeNees e4 e t e i e I e 4 e t I 8 Mim t

  • I @ t *t M4 @e $

s i e 4 t e + Np 1 e s I t t t t F + - + - + - - + - + - +t - = + - + -.6 l =+ 4 1 6 4 4 5 9 0 4 4 1 9# A s @ 4 @ t @ e @ s@ s@ ses > soeQe oeo4 0 oeQiot ot s W e e a e e e 4

  • t 4

6 6 a s t # e a 2 W W 6 o e M.e, e W # W W eW eweWe e caWe et ei mint e.i @N - i o.... @ t e. s s ~ M. a si l. : e -1 8 68 a l @a@ 4 $3 @ t e6 m e .a e s - g aNe I e ,4 - + - + = = + = + = + - - + - +I- + =,1-I e e i 4 4 i C. eent @ S cl @i t t t t t t t t i 4 t @ s@i sc { s e o s o. n @o. 4soe n e o e o. s ot o6oe o ae i t e i e 4 < s e a s i y W 4 W 6 Wt W4 W f W 6 W $ W l W S W G W t y N DB M t 9 4 h 1 08 G1 % l@ l g l OR M Q w f C4

  • s deme @t Et@ f w e*t M

W He Ja + 4

  • I 5 8 e t e t e t

=t

  • l et W

Cc Q Mea e @ s@ a@ e ye@ # = sN e e m og i t i e i i 1 4 4 + - + - + - - * = + - +e J a ma 4 Q es t e i 1 t t I t 4 i

==+=+-+=+ H JJ 9 9t h 4 @i@4 Of @ t @ l @ 4 @ e i U

== 8 08 04 Ql Q4 01 Cl osC4 Ot } w E5 WI 4 6 t a 4 4 8 4 t 4 6 I # 1 4 4 4 4 a 14WlW e Wl W4 W 9 W 4W 4 W 8 W4 6 TT QiM I T t

  • t a l M ce9 D N4 Nt h

J CO S408 -4

  • 8 @ eM Nema @

t-Te p a e e 4 e t e t

  • 4 e 6

+1

  • t e l e 4 e t

( WW SMI

  • E N INS Ti MI T4@t =6 t

l ' t t t I 9 6 8 9 ) w(

  • =

+ = + - + - - + = + = +l Ik ve

==+-+=+-+ L l i t t 4 0 0 0 4 I o ev wava~t @ e@ e@e @ e@ e@ t @ e [ MO VBCl O6 G l osoe osoeol os g ae 4 e e 4 s I t t a n e I t 4 s e e t 4 4 QQ) at Wl W S WeWl Wt W t Wt W S M4 WWE WW k 4 M 6 T t A l

  • G C E T O T I M f SI r

&>B MW B 4 QI m i @ 8 G8 80

  • l T I Ql
  • 1 3

W QQ m t

  • t a t
  • l
  • l +

6

  • t

+4

  • t a 4 U

QQ Qt Mia 4 @l @ l @ $ T4@ t @ l

  • 4 WMH 4

4 6 4 1 9 4 6 amW at + - + - + - =,4-+-+==+=+-+=+0 J J mm 4 4 6 i I 4 6 i t e %= ( ( $ 9 t h 6 @4 @ t @ 4 @ t @ t @ t @ t i a s o. i i i noe of I

o. e o s o i c. f o. e 3

st i t oi t i t i s i Q@ k g Qt W 8 W 4 W9 W4W4 W 8W B W 9 W 8 i>mN Wa QI M -4 T I @ t @ t Mt T eM a@ t me + S4 S6Q8 = 1 Ol N4Oc e4 GeCI @ I j (N Q e t 4 e t e t

  • t e t
  • t e i n
  • t i

V k$MI m e a f

  • E ND T4 @ 4 m #
  • t i

Q 4 t i 4 4 6 I t i p + = + - + = = + - + = + - = +I j. J> =+-+-+ w ( l 4 4 i b i 5 4 I (J 4 4 l G W t i f

  • t W4 4 4 4

6 k l 4 Ot Jk 4 I Qf 24 34 4 4 J t It J1 mJ8 2$ W 6 44 m kW X6 WI t >)f W i m 0 3)4 W i m i m i aW k 4 B 4 l bQ l W i ll>Q6w4 Z8 28 ca ee59 somer Wie<a*svi-a h@ &t J8 al w i 4 tQ t i L l 4 44Q6 ) l 8 4 J 0 1 6 4 i L h r t !i h } { 5

v) i ~;~;~; 2l'?: o;ono. w wl e.>=,,a.! g!x: so. r,,~..,

e
o.,.
=

~,M, i

  • -+-,-

l% i 8 T s N : p. ol?!

o w, w,l o '

~,..a,l zo :... J.l C. #

e.,a p, p,

l~. <<n,M, +- --.-.-. ol* e!.! l ~I?! ?l?; aiwi w.w.w, $l8 O I T t T t -g @ l osos oe

  • 4
  • I e l I'
  • l k l @ p % g C

g '"*-===.e..e -, I e e T ~ N 1 N p % g 8' 1 o8 oaoa c,,i W 8 * ' ie i e I b I W 4 laJ j Q g o'O '

  • 4 T 4 => p M e h a 3, g n

I I

  • b t

e g I * ' @ ( Mg Me I f

  • = * - =.I=,E -,t c

I I 4 t .e ?' O T N i h l A g o'ol os C o. a i e a a a e m, w'O8 ei wt wa we N N' N E N J mg Q $l ",,'".'A. ,l de N "I @ l Me Mt m M A kk a i 1 a aa '";"-+-+-+ g o og l% l%.' 3 v" ,i e,a -d e A w o i lfl J N 33 w8 s w.e e g w,w,w, m ol ? ' e l T e m,e s

== o'mi osmi% H w

': a:

ww ~~ N, N,

-+--.I~.I -.I IW

-w 1 o. @m wiv! s!~l j y;o;

o. i o.

u. g

o..

ax oa, 7,lO' W ' 2> ~ .l ei w wi

  • 0 wy 2 2,2

~, a em oloI e8 go w m i o;-. ildla: 2,m ~o i a-w am

, +!

~;s: w __ l

  • g i

~ ,;o: eso o. r S Z. -l o'wi 1,l4,la,: o *e, e o f , l O, l @ OM D -1 2*N $8 .i c' : 4.! 41 j i .w-O** w ( s a <4 3 I I i 4 l i Qq 4 I I b 4 , Qg I a I'w' s,a 2 s,y =v t a 3 w, aw "'38 koI wa! 04 a'o8 9 45 ,t h,e y,e we isiw l 4 4 8 3 i e i k P 1

D- +-+=*==+=*-+--*=+-*=+ 0 i 4 4 6 5 4 4 4 e I Tth 8 @t @ 4@ t 44@t @e@ i 4Q6 Qt Q4Q4Qf Q3 Qt olog El a ee 4 s e t a t e t i e e e t a t =l W GW 8 W4 Wt W t W4 Wt W1 W 4 W l a 8 @ l-Of h ICI T t @ t = 404 d4Ts@ l Mt Ql T* 1 t @t @ 4@l@ & 8

  • 1
  • 1
  • I e g 1 h t o i

@l @- t e 4 e 3, t ( @4 NI NtNa=9 e i 4 e s a e t i t +-+-+--+-+-+--+-+-+-+ 0 0 6 6 8 4 1 4 9 I T t h i @f @d @t @ t @ l @q@ 6 aC4 Of O401 C4 O4 O*Q8 C1 ft i 6 e a e I s l e s e e s. e I a 6 0W t W4 Wt W 8 W I W6 W4 W l W 4 34 T I @ I Osh 8 01 @ 4 44 SI T4 dlNe 4 a I

  • e e t
  • I

+ t a e e I. B MS Ml OG T 1 Ql= DN 4 W I e 4Mi

  • l

@t @ t @ l Mt ml NI = t t 0 1 4 4 9 I t t e +-+-e--+-+-+--e-+-+-+ 9 e i I 9 4 4 9 I 6 OI T 4 h a T 49 t T a @ aT i T eT l =6 00 06 Crot os cl ot ot Ce 06 s 4 i 4 e e e i i 1 e a e e a t i e a$W t W t WI W lW 1 W l WeW4W G b l @ 8 @ t @ t S4CI = 4 h I T f M S It = S Mf N eQ45 4 N E QA Mth i > t + 1

  • i e t. 8

+1 e I e i e 4 t M l a e

  • 6 = t
  • 4 31 = 1 =l = t t

I e t i I 6 0 6 I +=*-+--+-*=+--+-+-+-+ 4 I e t 4 9 9 6 i 6 T I N t @ l @t @ t @ l @ 4@ 6 @ l b lC9 Qt Qt Qt Q4 Q1 Q0 Q4 oe W a o e a 4 e t e 6 a e a e e e a e e t Z4 W iWE W4 W t W i W I W8W6W I C4 @ s@ e eiSG M t Msgt @ t@ $ = 6 = I M. a QsN. t C, t e at Qg @ t = t I t u4. t . t 0. t . e. e ( M ee t @ l 46

  • 6 MI TG MlN t g

4 1 e 4 i f f i 6 4 M a e-+-+--+=4-+--+-+-+-+ 0 g 9 e 1 a t e 4 6 I 6 ( O T t h t @ 6 44 @ 6 @$ @ l @6 @ t 4 z eoeci ol oaoa o4 oeQ4on M O ae i 6 s e i s

  • e 6 6 e e 4 e i e 4 M

w w i W 6W 4 W I W 9 W 8 W 4 W eW4 WlW 4 g N > 9 @ l @ t @ t @ l @ 4 @ l @l T l @ t C = I m #Mt h t v8 @t Me@t NaQ4 WM J5 + 4 e l + 4 + 4 = 4 a 6

  • t e t e t W

QQ eM1 = t @ s@ e@c M6 MtMeNt J M eW 9 4 9 e I a e 8 a e m E as +-+-+--+-+-+--+-+-+-+ 4 C sa e a s i e e t I 6 e a sa

4. 9 t h #

@ a@ e@ 4 @ s@t @t h t g u

== 4 ot oe caQlot 0 09 00 Qt w E3 We e t 4 i e s 6 6 8 t t i 6 ea e e e d It W l W 9 W I W I W 4 W 4 W I W$W f TT Ol @ l @ t @ S k l @ l @ l J4 N l mt J QQ $t

  • 9 + 4Ni T 4 @ l h t O4 e IMt

@ l = 6 4 + 4

  • t
  • 4
  • 4
  • 6 s

e D 6

  • 0 *

( WW G M 4

  • I N t "s l @ 4

=4 = 4 = 4 @ 4 SS I e e t 8 I e 4 4 6 E QC +-+-+--+-*=*--+-+-+-+

== @ 8 4 6 5 8 t 4 4 1 6 W > t T I N I @ l @ l @ l @ t @ l 44#4 e> ulCl ot osot Ce 09 04 Q1 09 g e ee 4 6 e e a e e a 4 6. 1 " I i 4 e 1 6 0 QM E 6W I WG W lW IW t W 4 W9 W6 W 9

  • W3 WW k t @ l @ t T t Odh e

@ l @ th t @ 8 &E2 MM f t e IMS N im 4 O. f = G Nfh a@ l W QQ 8

  • t e t e t e s

= 6 e s e t + 4 e t V QQ @DM 4 e l @ l > l *l M4 Mehl

  • 4 W@@

4 4 4 6 8 4 s I t 4 g*W ga +-+-+--+-+- s--+-+-+-+ J

== t t t t t t 4 1 1 %= (( 0 9 t A t @ t @ l @ l @ 0 @ l @ 4 @ t 3 eosos oaot Qi oeot oto 7 4 b e e e t 6 i t 6 4 6 4 4 4 e 4 e a e i QM Qt W 1 W t W 8 WT W $ W 4 WI W I W t

==T W Ot @ 8 @ e N eol @ t

    • L @ IT 4 N I

>

  • S4 84

= D M6 =i T t N 4 = I Nt@th e (N e s ia et e t e t e t e t e l e t +4 W > eM t

  • I

= 4 = ( N4 Mt MONS

  • 9 O

e e e 4 s e e e a a W> +-+-+--+-+-+--+-+-+-+ s ( 6 1 I t 6 4 6 I 6 4 ( J > 0 t 6 1 1 1 0 $ 5 i k 6 Ol Et WT I e 4 > 4 4Q6 = a scs Je2+s* J,l Isa6 es >Q t I t>@t W i = # J@lW l a eW t WW k t i SWQt W 4 14 406W t Z0 2e os ee e t@g er ewe *ei>t us=4 4 e of We assi$4W f i e 4 tal i >. e t = i i e i T

f3 f) {Q} l'Q ( j I J TABLE VII-A-32 FORT CAtHOUN t RECEPTORS Ik ALE SECVORS 42-OH PH $PECIAL LOCATION # 16 cow.POHn AT 3.47 MILES NW 4.76E-04 MILLRADS BETA AIR DOSE = 0.4tE-04 MILLRADS GAMMA AIR DOSE = PATHwAv T. BODY GI-TRACT BONE LIVER plDNEY IHVROID LUNG SMIN pouur l i.49E-04 l i.49E-04 l s.49t-04 l i.49t-o4 l 3.49r-o4 l 3.49r-o4 l t.53E-04 l 3.55E-04 l FEAT l l l l l l l l l AouLT l 4.2sE-or l 3.80E-07 l i.73E-or l 3.96r-or l 4.osE-oi l s.970-os i 3.79E-oi l 3.79E-or l YttN l 2.59E-o r l 2.32E-or I a.s4E-or l 2.400-or l 2.soE or i 4 2sE-06 l 2.26E-or l 2.26E-or l CHILo l 3. 8E-OF l 2.76E-OF l 8.53E-OF l 2.9tE-07 l 3.03f-07 l 6.J9E-06 l 2.73E-07 l 2.73[-07 l Cow altu l l 1 l l l l l l Aouti i s.esE-06 l 1.OIE-06 l 6.48E-07 l 1.18E-06 l 1.3Hr-06 l 8.56E-OS l 8.90E-07 l 8.90E-07

  • itEN l 1.srE-06 l 1.33L-06 l 9.93E-OF l t.6FE-06 l 2.040-06 l 1.360-04 l 1.16E-o6 l 1.16E-06 l CHIto l
2. set as l i.9sE-os I t.940-06 l 2.72E-os l 3.30t-o6 l
2. rat-04 l

.nat-06 l i.e3E-os l INFANT l 3.98E-06 l 2.92E-06 l 2.9FE-06 l 4.96E-06 i s.33t-06 le6.6tE-04 l 2.18E-06 l 2.780-06 l VII-39 d

1 1 %./ ,l l i l l I I f g TABLE VII-A-33 i l FORT CALHOUN I RECfPTORS IN ALL SECTORS 07 08-88 SPECIAL LOCATION a 1 RES.vEG AT 2.02 est LES NNW SETA AIR DOSE = 1.32E-03 asittRADS GAanBA AIR DOSE = 7.09E-04 asILLRADS PATHwAv T.SOOV GI-TRACT BON .._.. ___.. ___ ____.__....__~. _____E &IVER MIDNEY THvROID _.-. ________....._______......____.... LUNG SMIN etuesE I 4.40E-04 1 4.40E-04 1 4.40E-04 1 4.40E-04 1 4.52E-04 l 8.03E-03 ____...____._.............14.40E-04......____._..... __......_...__.14.40E-04________ _....____._. ...___.__.1 l cROuMo l 2.77E ....._-__.__--___-O r i 2. 7 FE-o r i 2. 7 rE-or i 2. r rE-o r i

2. 77E-o r 1
2. 7 tE-0 7

--...___.._.....-_...___._..._-_........___...___.......l.2.77t-Or i 3 37E-or 1 vEcCr .I I I l-1 1 1 I I Aoutt 6 s.99E-05 l 9.05E-06 5.09 ............,_______...l_____.E-05 I 8.09E-06 l____.._.__.......... ...-...-.3E-04........ ____...._________.i 8.75E-06 l 2.s 1 7.20E-06 4 7.?OE-06 TEEN I 2,40E-05 I t.03E-05 6 l 9. ore-06 l 9.68E-06 2 I 8.24E-06 l 8.24E-06 .._.__.................l.. 29E-05______...-._._......_.___.. _.{_..13E-04_-_...._..._. -......... ..l Custo 1 3.95E-05 I i.44E-oS l 3.39E-05 I t.4f.E-05 I t.2aE _. _-.....__....___..- --_.___.I 9.04E-04_..._.....__............_..._._1 3.37E-04_..............._-05l 8,78E-C5 1 sNnAt i i i 1-1 I i l l Aouti I 4.30E-06 I 4.34E-os .._____..-._-.......________.i 2.oit-os i 4.6st-06 1 5.osE-06 l 4.34E-06 1 3.99E-06 __....._.. ______..._-.-....__.I t.93E-04.____......_....____..._.._..._. .I TEEN I 4.42E-06 1 4.4:E-os _____.... -........________..i 2.3 E . _..._-os i 4.8st-os i s.53E-06___.._________. ____..__....... 04 l .4nE-I 4.2eE-os i 4.0 E-os t ___.___.______.._.______..I 1 Cento 1 4.ooE-06 1 3.76E-06 1 2.38E-06 I _.1 4.4 E-06._....__.....____....______._-_.1 3.79E-06 1 3.55E-06 1 1 4.97E-06 f.i.asE-04 i INFANT I 2.34E-06 1 2.92E-0 I t.25E-06 l 2,85E 2.99E-06 I 8.70E-04 l 2.27E- ......._________..__.. __.6... ....._.__-06 l___..____......-.... ........__ 06 I 2.04E-06 I 2 i t .t t 6 VII-40 ~... - __._..- _ _-_._.- _,.. _ _. _ -.~.

1 l 1 3 i a a TABLE VII-A-34 1 i j FORT CALHOUN 1 RECEPIOR$ IN ALL SECTORS O2-08-8H SPECIAL 10 CATION s 2 DEEF AT 4.55 MILES NNW BETA AIR D35E = 2.5tE-04 MILLRADS GAMMA AIR DOSE = t.18E-04 MILLRAOS t PATHWAY T. BODY GI-TRACT BONE LIVER MIDNEv THvROID LONG SMIN I i l 7_29E-05 l T.2tE-05 l F.2tE-05 l 1.2tE-05 1 7.2tE-05 l 7.2tE-05 l 1.440-05 t PLUME _________.__________.__._______.__________.________-..._________.__________.__________.l___.78E-04 l McAT I l 1 l l l t i I A Dut i l 2.39E-or i 2. toe-or 1 5.22E-07 l 2.tbE-07 l 2. 24 E - 0 7 1 4.94E-06 1 2.04E-07 2 _________.__________.__________.__________.__________.__________.__._______._____.____.l___04E-07 l TEEN l 9.45F-07 l 1.26E-07 l 8.06f-08 l 1.3tE-07 l 9.3HE-OF l

2. 9 FE -Of> l 1.22f-07 1.2

_____.___.__________.__________.__________.__________._____..___.__________.__________.l.____2E-OF l CHito I t.reE-or l i.49E_oi l 5.080-07 l 1.60E-o7 l 9.e eE-or i 4.4sE-os I t.4 rE -or I t.4rE-or l l r I i 4 i VII-41

. _ _ _ _ ~ _, ~.m. _._..m_ ____._.m. m.. 1 i i i 1 l i l l 1 5 i L 6 t I t i e i i l l l. i l l I ( j TABLE VII-B-1 i l i t i i j FORT CALHOUN 1 DOSE CONTRIBUTIONS FROM GASIOUS EFFLUENTS .l UNRESTRICTED AREA BOUNDARY 1 REOUIRED BY TECHNICAL SPECIFICATION 5.9.4.a. I SEMIANNUAL FOR JUL TO DEC 87 1 4 1 4 l MAX] MUM SITE SOUNDARY GAMMA AIR OOSE = 0.19E-02 MILLIRAD MAXIMUM SITE BOUNDARY BETA AIR DOSE = 2.00E-07 MILLIRAD 5 i 1 i i l i 4 1 i ,l i r t i I ? i VII-42 i 4 t 5 ..w _m ... -. - __. -, ~ _.....

\\ . O .__.__._==+__.__.__._. 4 i e a e a e M W i @ se a o at e o 6o#eogiMa to@ lo=aooeo 1e,oeooeooeO,,t It a@s eoe+oI + +o4 = 0W e 4W

  • I W 8W =

0W =aW =

  • I W6
  • 9@@ t hOICOf CO4OOeoO6@l

@ t@@ t M so* 4 + eo I o a@ t 0 o 9

  • l
  • l 6
  • t e

I + t I @ e= ao eO to eQ s@ t a e a i i +====+.===+-+====.+-..=+====+t+a I I t 4 I 6 4 M ut 8 @ st 4 @ d 1 O at O af 4 O at t Mi i 8 O@ I Ovsoh eoo ioceob: oe QI eet

  • C6 i Ot +Qi, + o e + o.$ W f ee s 21 W e 1 W
  • aW
  • t W + 1 %
  • I W 3ahet moi hoi oc1 ogiocah e

.J 0 O @ t tN so i o t

  • 6
  • 1
  • 8
  • 1

= eo= e o. ge 4 n iM i = t N I Q i o so aMe i I +e==+-==,A.=-+e i i e s

  • =.=+e=.e+ee=

+. = + 1 I .t i 4 4 4 1 O I M se e @ at e M st : M d e M st i e at : M =eo@ so= SON I oeio@ < o ao 1 oa OI e@= 8 W t iO1 1 OI e@ t iN I e N 6 1 e a4 W

  • 6 W e iW
  • IW e iW
  • iW4

> 0 @@ t MQl @e4 MeI@TI MN6 M I e ZI e fi 4 .= 4 T=4MN 1 = *= t e 4Q4 e += 1 e 1

  • 4 e 4
  • t
  • I
  • 4 e $

e aN t = 0 = eN e= 1 = see e e i 1 e I e e o +==-+=+===+====+====*_+t = = + B t I a e i I e I N IM 3R 4 @dI @ W 4 O M i @ 34 1 >= pt 4 l"l I oa > tQwt Cw1 O@ to=1 oNeoM t oI E W l i et *C4 eeI steaNs e

o. t e i W

2iW a e leJ = 0W e IW e tW + 4 W 8 W8 4a O4@eI MQsMOe=Q4NOt @OtN* >2

  • = 0e@ f =

1 M aN 4M i @ t @ l ( ( Wt e f

  • 6
  • 6
  • 1 Q3 4N 0 **

4 *= f = 4@* 8 e i e 4 4 @ $Ne w 4 4 8 8 0 1 i M g +==+e===+====+++====+4 a.= + WD 1 I l i 1 4 i y 3a 3MWt @d5 @dt@Wi@dt h#6Me o aocsowech l o@ aont ONt Qs ae seasoa 6 No eN4 s=1 aoe e a M W 6W

  • 4 W e I W e aW
  • 1W
  • aW 1W4 4

>t@@ f MC1@C4eC1 @Qt @C4=4 T W@

== 8 4e@ I

  • e I h 8 =

4h t t@t s .J t 6 e t

  • e
  • 4
  • 4
  • 4

+e 6 W =W GN to th 4h IM 4 @ INI a g@ I l e e i I i y g >Q +-+====+====+====+====+====+t = = + Q t t t 4 9 4 4 i M 38 0WW4 @ 30 8 930 l @ st 4 @ 30 fi i h NE 10@ 8 09 4 C O I O = l O N a c. h O4 eQ WI sN I : 0t i e4 egi sM6 = l t 4 %== 34W =4W e 4W =4W

  • 4W
  • tW
  • 0 tail 4 N>

Q t @ ** I MQl MQt @heMQ4 @Q4h a

4 81e@ t=

4 @ lM iQ 4 9 1*I e .,A 4 e t

  • I e

t

  • 6 e

I

  • I a 4 h3 iN 4=

1N 4N 4* 4 @ 4 fi 4 e& a 1 6 t t a s %0 + - + - - + = = + - - + = = + - - +a =* h4 6 1 1 e t 6 e t Q > t M st 8 @ st 4 @ st a @ W e h at a h at 4 M a O U*Q@ IoetON1 CM4OM ao=aoI W 4 e & @s e ol e=a i NeeOI ec 1 1 gIW 4 W e tW =8W e tW e 4 W e twt 4 > I@@ lMOI eCeeOeNO4 eCICe l e. @ E I t = 1@

  1. M 4O 6 @

l@l .J ()

== 6 4 e t

  • 4
  • 4 (W

Q4N 0

  • e i M i @

4@* I

  • t
  • 4 4 N iN4 3>

e i 1 1 8 1 I I 23 +==== +==.==+a===+====+.-==+====+==+ Z= t I e 4 6 e i I ( 0M38 0 @#4@M0@$f@W9- @$8Mi

== 4 iCet QT t QT 1C@ 4QM4 0@ toe 32 > I e@s oa a=a eoae=i eoea a w( o4W 6W + 0W

  • I teJ e ii W = 0 W e IWi

@J Q8@h 6MO @O8@N @Q8 @Oe@ l @ $e@ t = 4 0 t O e e@ 8 @t .F ( 1 e 1 + 1 e 6 3 > t N 4 = t 9 i@* I

  • 4
  • 6

. fe) e e= tN6 9, 4_

  • .==_+_+===+==.1 e

i I +_+==e J l 4 4 0 1 9 4 ( > 0 4 1 4 9W t 4 4 y ( 8 9 I a.J t 4 + 1 36 0 0 4 8 4= 1 4 JI si. Ii t 2 I.J 4> t 3 I t < 1 g > 0 0 Q l 4 4 W t I t= 6> # 0 ( a eo 1 T ec e3 : ( eoe .f w &eJ e i I w IO 4 W 4 *= I I& 6 i = 4 > 6W 4 3 4+ e a

r p N Nn,' v v TABLE VII-D-1 FT. CALHOUN SEMIANNUAL RELEA5ES FOR JUL 1987 TO OEC 1987 02-08-88 RETS DISCHARGE =8.02E+02 CFS SOURCE TERM MULTIPLIER =1.00E+00 50-MILE POPULATION =7.35E+05 FRACTION --- ADULT =0.66 TEENAGER =0.14 CHILO=0.20 FRE'W ATER SITE

  • +
  • AOULT Dost FACTORS

+ + + INGESTION DO5E FACTORS SHORELINE (MREM /PCI INIAME) (MREM /HR)/(PCI/M+*2) NUCLIOE CURIE /.5vR BONE LIVER TOTAL BOOV THvROID MIONEY LUNG GI-LLI 5 MIN TOTAL 800Y RECON 335R 89 2.02E-04 3.09E-04 0.OOE+00 8.85E-06 0.00E+00 0.OOE*00 0.OOE+00 4.94E-05 6.50E-t3 5.600-13 385R 90 4.44E-04 7.6tE-03 0.OOE+00 1.OOE+00 f.86E-03 0.OOE+00 0.OOE+00 0.OOE+00 9.02E-04 0.OOE+00 0.00E+00 9.OOE+00 531 931 4.8tE-03 4.16E-06 5.96E-06 3.41E-06 5.95E-03 1.02E-05 0.00fL+00 3.57E-06 3.40E-09 2,80E-09 8 OOE+00 55C5 137 1.54E-02 7.9BE-05 9.09E-04 7.15E-05 0.00E+00 3.7tE-05.1.23E-05 2. TOE-06 4.90E-09 4.20E-09 55E5 834 7.56E-03 6.22E-05 1.48E-04 8.OOE+00 1.2tE-04 0.OOE+00 4.80E-05 3.59E-05 2.59E-06 f.40E-08 9.20E-08 8.OOE+00 27EO 58 9.2tE-02 0.00E*00 7.460-07 4.6FE-06 0.00E+00 0.OOE+00 0.00E+00 f.5IE-05 8.20E-09 7.OOE-09 4.00E+00 25MM 54 0.06E-03 0.OOE+00 4.57[-06 8.730-07 0.00E+00 1.36E-06 0.OOE*00 9.40E-OS 6.80E-OJ 5.80E-09 9.OOE+00 27CO 60 2.29E-03 0.OOE+00 2.15E-06 4.72E-06 0.000+00 0.OOE+00 0.OOE+00 4.020-05 2.OOE-08 9H 3 6.27E+01 0.OOE+00 1.70E-08 f.OOE+00 1.34E-07 4.34E-07 1.34E-07 1.34E-07 9.34E-07 1.34E-07 0.00E+00 0.00E+00 9.OOE+00 2700 57 9.9tE-06 0.00E+00 1.75E-07 2.99E-07 0.00E+00 0.00E*00 0.00E+00 4.44E-06 568h 140 3.82E-34 2.03E-05 2.55E-08 1.34E-06 0.00E+00 8,68E-09 f.46E-08 4.tBE-05 2.40E-09 2. TOE-09 f.OOE*00 1.OOE-09 9. TOE-10 9.OOE+00 402R 95 9.56E-06 3.04E-08 9.76E-09 6.6tE-09 0.OOE+00 1.54E-08 0.OOE+00 3.03E-05 5.80E-09 5.OOE-09 8.OOE+00 4tNS 95 1.86E-04 6.23E-09 3.46E-09 4.36E-09 0.00E+00 3.43E-09 0.00E+00 2. TOE-05 6.00E-09 5. TOE-09 5 7L A 940 1.30E-03 2.50E-09 9.OOE*00 1.26E-09 3.34E-lO O.OOE+00 0.OOE+00 0.OOE+00 9.25E-05 G158 125 5.19E-03 2.23E-06 2.40E-08 4.48E-0 7 1.9BE-09 0,00E+00 2.33E-04 3.97E-05 3.50E-09 3. TOE-09 8.OOE+00 f.70E-08 8.50E-08 1.00E+00 47AG ttOM 2.27E-04 f.60E-07 f.4BE-07 8.80E-08 0.OOE+00 2.9tE-07 0.OOE+00 6.04E-05 2. TOE-08 8.80E-08

8. ODE +00 VII-44

\\ l 5 5 5 u u U W W W E 3 E = m m N> N> N> + O eC eC eo e0 e O Em 3e Im W% ww Ws laJ z=J KmJ =Ud =v4 =UE Ja> J4> Jak Wwo wwo Wwo 2%> m n A k2 I Z s= sa s= 3* 3* 3* We we We 3 2 2 3 3 I w w w @v@@@@@h@@@@@ eT@@@@@h@@@T@ @T@@@@@h@@@T@ =O000000000000 =0000000000000 =OO00000000000 Je a e e e e a e i e e e e Ja e e e i e e e e e s e e Je e t e e a e e e e a e e JWuWWWWWWWWWWW JWWWWWWWWWWWWW JWWWWWWWWWWWWW e@C@NTT=@Teme@ s @@mTwo@m=OTOM eemm@@@thmeOTh o .N.T.@.N.M.M.O.=.@.h.v.T. o. .T.S.O.=. e.O.N.@.T.O.M. c .T. @.@.@.h @ C.T.M.T.c.h. =@

==N =T TN==N=M-TN=$@ @N==N*NNTN==4 @N===@NMTN==M e COO @@CObeOOOO OOO@@OcheOOOO COO @@cohh0 COO C000000000000 0000000000000 0000000000000 Ce o e e e + + e e ++ ++ 0+e o e e ++ e e o e o+ e de o e e e o e e a e + e

  • ZWWWWWWWWWWWWW e

ZWWWWWWWWWWWWW 2WWWWWWWWWWWwW e DOOO=@COWMOOOO DOOOT@OOmNOOOO 3 COO =Nochh COCO J O.O.O.@.M.O.O.O.M. O.O.O.O. J 0 0 0.@.=.0 0 0.M.O.O.O.O. J O. O. O. e. *. C.0000000 e m COQ =NOQ=NOOOO e COOMTOONTOCOO CQce@COM=CCOO = y e COce@Och@e@Ch co@@@ ooh @e@Oh CO@@@COh@e@Oh O, 4 O00000000000,0 >O000000000000 e > C 0, 0 0 0 0 0, 0 0 0 0 0, 0 O e We e e e + - e e e e e m W+ + e i s e e e a e + e e We e e e e e + e s e e e W C e E ZWWWWWWWWWWWWW E ZWWWWWWWWWWWWW E EWWWWWWWWWWWWW =

  • F a

CaCOON-COOTeTMO= CaOOON=OOOTevmoe CaOOON=OOOTmTmom M -m W O W W = C. o. c. h. e. O. O. M. @. @. T. O. S.

  • W = C.o.c.h.e.Q. C.M.@.@.T.O.@.

> W = C. O.O.h e.O.O.M.@.@. v.o.@. O h vug e usx g ugg N. W / \\ g i I C u se OO-MTOO=e* MON 2 OC-MTOCae-MON O CO=MTOC=e= MON i N> 0 wa s> W-gKj V ZOOOMOOOONOOOOO > 2000M0000h00000 u FOCONOOOONDOOOO 8 w W = = 0 0 0 0 0 0 0 0 0 0 0 0, 0 e w W==0000000000000 U Wa=OOOOOOOOOOOOO 4 e C++ e ++ + + e e e e e = - e Oo + e *+ ++ e e+ +++ 4 e C+ + 6 + ++ + e oe + ++ w =* C=aWWWWWWWWWWWWW w OmmWWWWWWWWWWWWW O=aWWWWWWWWWWWWW 0 0 Qv> ooh 0000@OOOOO Qu>OOmOOOOMOOOOO W Ou>OO=COOchcOOOO W A I C O M.C O O O O O. O.O.O.O. e W 4:0090000000000 e Q O 4 Z J.O.N.O.O.O.O.O.O.O.O.O.O. g gwp e rse O Zwe - - - - - = - 4 a 03 CONOOOC=COOQQ O 03 CO@OOOONOOOOO O 03 00=O000M00000 W w =W O =W aw J d >g>@MOe@@@h@@@Oh >E>@M@@@@@k@c@@h km>@M@@@@@h@ee@h W eaOOOOOOOCCOOO=O O 0300000000000000 Z 6300000000000000 a 2 WwOs e e e e e a e e i a e e W wwoe e e e e a e e e e i a e a wwce e a i e e i e e i e a e d SWWWWWWWWWWWWW w d SWWWWWWWWWWWWW J W W O CWWWWWWWWWWWWW = J W Z NN@@@@O@N@@@c I 2 @@@ONeem@C=@= Z Z Noechd@h@mm@= J @ M.N.@.C.@. @.c. e.N.=. =.@. J T.T.M.N.@.N. c.o.m.h. o.*.e.

J M.c.@.o.O.N.M.Q.e.@.T.@.~. v = m > = q O 4 4 >*NT@@N@==cNT= >MT=Te@=NTN@=N >S@NT@@NMcM=NT H O O O e WOC @TTh@ hee @@h e >Co@TT@@ hee @@h e POO@TT@@hhee@h 0000000000000 0000000000000 0,000000000000 + e a e s i e e e a e e + + e e e e e e e e e e + + e e e e e e e e i s e EWWWWWWWWWWWWW EWWWWWWWWNWWWW EWWWWWWWWWWWWW ANNT e Woch -Tehh @Nehh WOOhNhehmbTM@@ > O. C.O.M.N.h C.O.M. M. M.M.N. e WOONTTN@@eT@NT e D O. O. @. C. h e. =. O. = D O.C. S.T m.@.h C.T.e!M.h.@. "J O O T h b M

  • M = @ = S h m

m JOOh==@N= mat== JOO*MMe@NkNSMM e o e TN@vcOOO@e@@h mM@TTOOC@heek MN@TTOCOTheek e C000000000000 0000000000000 0000000000000 =

  • e e e e +++ e e a e e e a e e e + + + e e a e e e e e e e + + + e e e e a WWWWWWWWWWWWWW WWWWWWbWsWWWWW WWWWWWWWWWWWWW 3

ZOThheOOOMNTed ZeNmNTOOO@T@~m Zm=NMeOOOT=@N@ 2 Q @ O. @. O. O. O. O. O. e. h.N. T. O. Q M. N @ = N.C. O.O.N.O.@.O.M. O S. @. T. c. @. O. O. O. h. =. e. =. @. W e c. c T=@=eOOONMhMN

    • =MNCOOe===@

NNe@TOQC=NmN@ W TTmhMNm=T@TMT TTMNMNm=T@TMT TTMNMNm=T@TmT v C000000000000 0000000000000 0000000000000 E g i e i e e e e e i e e e a mi e e a e i e + e e e e e E e e t i e a e + e e e e e 3 >WWWWWWWWWWWWW DWWWWWWWWWWWWW >WWWWWWWWWWWWW O @NT=T@w@hN@@Oh @NT=T@=@hN@@QN @NT=T@=phNGGOh e . D. T. e. c. d. N. N N. e. c. e M. N. . O. w.e. @. @.N. N.N e. @.e.M.N.

  • O v. e. @. @. N. N. N. e. c. e. M. N.

2 g WNTT=h=N@mpe=N WNTT=N=N@M@=*h WNTT=k=N@M@e=N = = = =g a M E 3 3 3 3 3 3 W vmO=hweOMO@400 vpO=hveC90@@CO W@C=hteOMO@@ao e e@mMme@ T@@T= eeMMM@@ T@@T= e@MMM@@ Tp@T= 3

=

=

==

=

=

==

=

= =e 3 N W Or4 eeOO deedd Ces eeOO < aced OEa eeOO < reed mee=UvvvTer42J4 wee =UvuuZeNZJ4 wee =UQuuZeNZJ4 J JeeM@@hhe@O=hh JWGMc@kha @O=hh Jemm@@hh =40=hh 4 7% UMM@@(NN @TT@T UMM@@@NN @TTdT UMM@@@NN @TT@T [ \\ 3 3 3 0 j = 2 = ,Qf

O O O TABLE VII-D-2 e e

  • AS LOW AS REASONASLY ACHIEVA8LE
  • A OUL T D05E 5 DOSE (MREM PER.5VR INTAME)

PATHwAv SMIN SONE LIVER TOTAL SODY THvROIO KIDNEY LUNG GI-LLI FISH 1.40E-02 2.25E-02 t.63E-02 5.48E-04 7.53E-03 2.52E-03 t.00E-03 DRINMING l.7tE-04 3.72E-04 3.73E-04 5.68E-04 3.IOE-Of 3.28E-04 2.98E-04 SHORELINE I.92E-05 1.64E-05 1.64E-05 1.64E-05 1.64E-05 1.648-05 1.64E-05 1.64E-05 SWIMMING O.OOF+00 1.97E-07 1.97E-07 1.4FF-OF t.97E-07 f.97E-07 1.97E-07 1.97E-07 BOATING O.OOE*00 9.85E-08 9.85E-08 9.85E-08 9.85E-08 9.85E-08 9.85E-08 9.85E-OS TOTAL 1.92E-05 1.42E-02 2.29E-02 1.67E-02 1.13E-03 7.86E-03 2.86E-03 1.32E-03 FISH ~ (MG/vR.HR/VR) DILUTION TIME (HR) 5HOREwlDIH FACTOR *0.2 USAGE 21.0 7.3 24.00 DRINMING 730.0 30.8 18.60 5HORELINE 12.0 7.3 0.00 SWIMMING 12.0 7.3 0.00 80ATING 12.0 7.3 0.00

  • ISOTOPE CONTRIBUTION
  • PATHWAY 5FYN SONE LIVER TOTAL BOCY THYROID KIDNEY LUNG GI-LLI FISH SR 90 2%

C5 137 59% C5 137 54% I 133 94% C5 137 60% C5 137 60% C5 137 25% C5 137 70% C5 134 39% C5 134 44% H 3 5% C5 134 38% C5 134 38% C5 334 15% C5 134 2b% H 3 1% CO 58 -31 MN 54 2% CO 60 I% H 3 3% M8 95 45% DRINMING SR 89 1% C5 137 14% SR 90 7% I t39 51% C5 137 6% C5 337 1% CO 58 2% SR 90 65% C5 134 9% C5 537 9% H 3 48% C5 134 3% C5 134 Is CO 60 In C5 137 23% H 3 74% C5 934 8% H 3 89% H 3 84% H 3 93% C5 134 9% H 3 74% $8 125 12% 58 125 1% SHORELINE C5 137 56% C5 137 56% C5 134 88% C5 134 18% CO 58 Is CO 58 1% CO 60 17% CO 60 te% 58 125 4% 58 125 4% SwlM M f I 935 4% C5 137 17% C5 134 25% CO 58 25% MN 54 t% CO 60 12% LA 140 6% 58 125 4% AG ItOM 1% VII-46

=MeeWh* =$$$$$$$$ $$$$$$ J000000 Ja@cMN=Nw

n===

Ja a e e a e a N= g t WWWWWW t =~ehCON = ONd==cM CONwevCMc meOMod

  1. (%

@MMem@ @o@

  • N

.a@a

== == \\' Muuv3vI2 Muu1JM 200020 e 200 de OM*o9hm 0$$ 2000000 Z=> MNew De I s a s 3@M N JWWWWWW J =NNOO@ @@*=@= Ng hgMc MM Mn u N=@=WM

==

=

MM MW e vu vure >MweekM WC00000 aQe @Me 2e a e e a e Z@M e CWWWWWW O =95NOOc = E N.=.=.=. @. c. ght hwM MM MM ON@=ce

== == N e O= MM WM yy yv3 a a W 3 E O 4 e > OTWe@hwu O$$ 2 =0C00004 =@M O@ = Oe a e t i eh Q@ @M EWWWWWW g E >@@kOO=Z e INe==@@= I=M eM d M * = * *. -Q >M M TM@=@@= = = W R J E W e W E =1 =2 4 4 O W 3 M = W g Z E >MT@@hM 8 u 3 0000000 U=NW NeN= Q 4 w Os e s - e O mv = m a SWWWWWW e /~N NchoOm N w ) J W J O. =. = ** C M JON t OktM 4 m e M 4 (@MM @MM g e Q >@Nma d@

=

== 2 O O O w W O a

  • Mee EHH J

M g WWW MUUZ M 4 I q W wo0000 g a W o. @. Q. Q. O. 3 M ENee@NNaveOOO 2$$ 4 WOOOOOOWN-WO@ =TM De e e e a e >@M Na@ 3 =WWWWWW = Q JDOkOOO J w N. T. =. =. @. N. AT NTM MM MM M NN@=WN

== == M MM MM = M. c. M. M. e. vu vu: e W w e t DhCNhN M J M = O WNwe@kNO W$$$ e 2000000 e ZNO@ acme @e=NT TN@@aN@T= 0 0: e i s e a O NN @N p= = -NN = CWWWWWW e NNhOQc 3 T. @. ~. ~ @= T Chg @Ohv hveOp ahwe900eo e e @MM mpMM mmc @N MMM@@@TN= g

=@=c

== == == =

=

=

W 2 EMM aree eeoce eMOIO4ed O WWW MHWU UUUWM =UWUmWJet Q a = E 4 3 e 2 2 9004200000 2 = OOCCI = E =

  • @' C h h k

@e=h9 W X e + e E c= = M WWWWM-=@@@ Z A W NOON > c 0 0000% v hveco +0 mmc @N e * * =00-3 W

== = w 4O MOOOe i W uvvve d O e M M = a 3 s e 6 W W W 020 020 0 2 3 2=20 Z=20 2 = e =J=2 =J=2 e t = J t 3 gw3=J WWE= B E W IZ233ke @=223> II 2 2 3 T We=O=e> =4 me = = e=51300 =E 30 <= m 4 4 E O ve e s > EO de e EE O ^ I 1

=TWohhv =$$d***d$$ J000000 J=eeMN=e@= c de e e e e n J N= M e eWWWWWW s =MhNOo0 = OONTeTOmeo M d e. O. @. M. @MMco@ @g I ^% ) NM=Nac

== = EeeOKO >N/ evuvauI24 I OMT@hhM O$$ 2000000 2N@ MN@c De a 6 4 e 1 3@M e JWWWWWW J @NNO4@ N T @ M. a @ NT NTM4 MM MM N a e. NM=N=N

==

=

ee me e UV UUZe e >MT@hhM WOOOOOO Woe @Mm 3e I e e e i Z@M e OWWWWWW O =NNNoc. = MT=@M-N ghT NTM

  • * * *
  • e MM MM NN=N=N

== == N ee me + O vu uu: N W g X Q e > OTWehhMW O$$ 2 =O000004 =@M cv = Os e e e e i m om @M EWWWWWW g a >@eNOchI I m.o.@.M.=. M.w I-M -M e w O -M M c e Te=N=== = = W 3 J E w e W m -I =I 4 4 W 3 = w q Z a >MTehhM u 5 0000000 vh=4 NTMC g Os e e i e e O eT = h w O SWWWWWW G l NMNCON JONT CATM O w J W J@h@M-@- d@MM @MM w e. e 4 a * * *

  • T O

>MM= Nam >== == N# 2 C O O I i W a >2ee Edo m y o E AVV eUUI m 4 4 I d W wCOOOO 4 5 W O. W. O. O. O. p 3 e ENWehhN=TeOOO m** 4 WOOOOOOWN= wa N NTN Da s e e i e >@M N=@ 3 =WWWWWW = O JeONO@M J J @h@M-Q NT hwM e e a e e e MM MM e =T=N=N

== == 4 2 O ee de vu vv: ? = M.e.M.M.M e e e sNehmb d tt WNTchhnO W$$$ z000000 e z-No

NM-co-NT Thoc=N@T

e e ' Os e e e e s O NN eMe c= = =NN = W mWWWWWW G T@ Node 5 ONT e3AT NWeO@ =NTeTOOco e N M. @. M. a h. + e @MM apm9 eeMe@N MMM@@@TN= e

== ch

==

=

=

Q -M=N== 0 2 mee aree eeOO@ eeOIOded O eUU eeUU UVWWA =UWUaWJe( m = E = 0 s e = 2 J Z cocemmOOOO 3 = @mekT 0 0 0 0 % @< = * * = e ++ e

  • CTTT

=

  • c=

= = Ee WwwWm

==

Z e I TOOT > c O P NOON % J hveO4 ed MM@@N Q + *

  • NCONs W

== = = 0.O deOOO .f W vuvWe 1 O Q e e e = 3 e I W W W O20 020 O Z 3 Z-20 E=20 Z = a =J-2 =J-Z e e = J B

  • WE=J
  • W3=

B E W l II* 3>< Iza3> II Z a 3 e=g=30<

  • e

= = we= =<> <= a 3 i 4=E 300 =53ee e a. O e awo ee-5 . - ~,, -.

wCggM =A JOOOO .J N .J e e e e JO eW WW e

== 0 Od

== 00. O. G. OM ONON Z 1888.e $**eAA O e .J W W W W .J ONOm ktMb C. M. O M. MM N OMOM

=

de e uvIe >OeOe >d#A WOOOO W@Mm 3+a e s 2 m OWWWW O

==0OOO

  • =

3E O. 9. O. 9 XN9M Mn O=O=

== N Me e O Uv2 = m W g E O 4 e e > OOMOMu Odd I== 0 0 0 0 4

== c T e O+e + ew ONN awWWW a a >ONOMI I D. =. O.. > I-M e e eM c. O.O O W 3 .J E w a w

  • = I 4

W 3 ~ w I g >O909 >dddd 8 V a UNNN= 0, 0 0 0 O= e Q w e e e p WWWW e e ONON JOktM J O.C O @ J W m 4OMM 4 e-M 4 e O >CMOM 8 3 O O O m.e LLJ O a eqWH w W d g nWWE ec a:(, w w0o p a W o. d. 3 e a O at O w== ar e ad## ( WOOOOWN= w04N D+ e e a >M=4 3

WWWW a

=.J O M O M J 0 N9M O. d. C. @. .J MM H Q@O@

== 4 2O Me

  • = M e.

UUZ > a e e 3ko .J M W WOTO90 WAddd e 10000 e INMmM A O+ e + t O 9M= eWWWW e O O-O= eONv

0. m. o. e.

e e@MM e O CMOM = * - 2 2EWH +AUU .O. e E E 3 e== 2 4 Z O O E O. O. OOI E

  • =

== b g + +

  • OO e

Wwa M 2 e Z C0> M O C. o. w v d = 00s W w a O w 0 C e e e

== 3 o W 02 0 0 Z >2

2. =J

e e

a n w w.J 3* 1T e I IE e.Z. > 0.2 > = = 4== 0 =s

  • 5

& m, > bo e &C

MMTehN addddddd ddddd Joooooo acenN=Me N=N=

at 6 i t i e JNa T J eWWWWWW 8

== COTS $ = fm Q M.N.N.T.=.e. QMTOTOMc SCMoe \\ _j)- MMee@ e e@ WN ~@==~~

== == r emoIOvrI C0 <e i vuv vvzJe ONNTWNN Oddd Addd E000000 ZQe=

=TN 3e i e 6 a e 3@M e

JWWWWWW J T.OTS@ @ Q N T = e. NTM NTMO MM MM N

====NN

==

=

em ee e UVI UU3e e >NMT@hN bdd ddd WQQQCQQ WQe @M@ 4 2s e e a e e g@M e QWWWWWW Q modOTS@ = X @ @ N. T. =. T. ghT ATM r MM MM @@==h@

== == N. Me em O uv vu 4 a a W g E Q T = OMNT@hNU Odd Z =0000004 =Tc -e = Oe e e e a e a O@ eg b RWWWWWW a M >QNOT@et L I o.n N. T.=.=.=

==M -M c. c

  • M M

T===hh- = = 3 2 W W 2 =Z =% 4 g 3 3 W g 5 >=NT@ha >dd Addd 3 0000000 UTW h@ev Ce 6 6 e 4 e o@T h O w SWWWWWW C I e @.3Q9@= M O W a = = N. T. =. M Jhv ChTM W w e e (MM @MM i y 3 Q >====N

=

O O O O M

== y a = m ree mee A y g UU MVVI O U 000000 0 W o. o. o. o. Q. W s 3 E=NT@h==TNCOO MWW WWW O wCCCCOOaN= W@@ TmW W De e i e e a >@M = h =WWWWWW = U JTTQW@@ J g W @ = N. T. =. h. NT NTM a MM MM 4 W

==e>

== == e ro ee ee =Q0000 vu vvI e e 3===== 1 a e WaMT@haQ WA#d ddddddWWW i e 3030000 e 2No@ acM@ @e=hT Thec=N@T. W Ca e s e e e C NN QN @= = =NN = mWWWWWW C e MhCT@e 3 o O O. N. N T. =. 0 Ohe @ CAT NTece ahveTOO@ MmMcc@vhO e @MM e@MM mmc @N

c==>

t

== O

== == =

=

=

2 See seem emoCe edOROced O evu eeuw vvvve =uJW3vset n = E = 3 F C v J z T o o W g o. o o.o.o. = z dddWW C000. 2 = = 3 E + eo e .=ONNN = E cWa=NT e WWWWENM=== Z e = 9 o QQQo> 0 [ T o.o.T.Q = a v k WeCo W ( r MM@@N e =QQas W t =

== = w a i Q o W meOCS = v u w u ti W 0 0 A = e k = e 3 l e e = l W W i E 020 020 0 Z 3 W r O 2=EQ t=3Q Z = = e =J=Z =J=2 e e = J k 3

  • W3=J
  • W3=

3 W L IE2makt Z233> II z a 3 d v we=O-C> e=ome we o e-g2300

a23o a

a 3 = = 1 w awQeee> b&eme e as Q e I r p

em M M (P @ W N

    • d *
  • h N = N ed$d*** *
  • f2 $ d

.J eg g o o o g .J = @ en

N===

a1 i e i i 4 .J N *= t2 9 awwwwww a =oeoM=e

== Q O.. N. o. o. o. Gokte9 cme oeomo@ $MM@@@ m ese WN ge@eT= =* A) ~= (V cuvviuzt Avvzs<e =aro o 00 a oNM,$@N o$$ 2Oooooo 2=h MNme 3e e e e e e 3WM N= J W W W laJ W W J NNoM=9 = @ h o o. N h9 h9Me e MM MM N Nm@eTN

==

=

HH We e uU UUZe >NMwe@N woooooo woe @Me 3e e a e e e Z@M e o w w w taJ W w

== @ e o M = N o X = @ N. O. O. e. gh9 hvM T@@eTT M.a = M MM

== N. MM He o vu vuZ = a w a m o 4 > OMNe@@Nu .Z.

== c o o o o o 4 .o $ $ =@M =e Oe a 4 e e aw oa @M awwwwww a 2 >mNoM=M% I T N.h o. o.@.> I=M ~M c. M = @ e g. o. >M M = R e a w end E .* Z

== Z 3 e wg >NMT@@N h$$$ 3 0o00000 v=NG N.= e h a P% w oe a e e e e o cv N I e W W w W w blJ e Q e NMCM=@ w J @ @ h o.o g g g@@@e,m. j Joht ch9M W 4.. - 4mMM @ M fi k g 9

== == q eWW eWVI >,re are LkJ W I .-v o J Q wooooo

  • llp.

m o w o.o.o.o. o. m = M e @ @ ~.3 s =9Nooo E$$ H o wococoo*N= wom =em w >e e a e e s .a @ M N=@ .e W W W laJenJ W a U J# mom =M J w @ M. N. o. o. N. N9 h 9M s w .- N @ e g .M. M MM =

== = c.0 0 0 0 vu vv2 e w e 3.===.= M J o w=Mwe@=O w$$$ e 2o00000 e rNo@ = cme @e=NT TN@c=N@t= Q oe e e a e e o hN @N e=

== =NN a w taJ W eaJ IaJ W e = T@oM=o 3 o @ h. o. o.". ch4 mobT hTmod =h9evooco e g

,.@e,

e SMM e@MM MM@@N MMMc@@gN..

== == == . ~= =. W 2 mee same 3000m MHorovec [ .o. duv revu UWuve =vuuavudt O a t a ( 3 e 7 o c, o o f.@.0 0 0 0 9009mo Z =

  • a =

@m-he w w e e e ok>h > u e- = m wwwwa==$@@ 2 e w =o0=> c o

e. o. o. e.O v

h9eoo y mmc @N i e hooks w I'

== =

== w o o +@00m eaJ UWWWe w c o a e i e.e e

== r M 3 e .e e. w w w 2 030 CE@ Q R 3 0

2. =.=J

.Z. 0 2 =.=J= 220 Z =.J =

== e 3 e e = ( i B g w E .a swa. m w 4 II T > e.t. s.a. > >< eh.2

3. >

II 2 3 a u g >e c O g eo g 300

g to g

c I 3 .J &wo e4> wo 64 e e &w o e e 6 ___e

Mme9hN = W W ri d d r$ d W W d .J ~ e :AMN=ce= e JuuCOO,o aTTe s s a N= M e WWWWWW 8 .t. N e c e e c =00hve9CMeO M O p t. e. @. M. eMM@me et /m \\

pe e

v)- a++OiOvrf< r \\ evvv s + NNT@hN Ad dWWW 000000 N@ hN@e a e e e e e @M e. .J W W W W W W .J l-h4OeO9 @oe@MN h9 heme MM MM N a e

  • + e

==**eN

=

=w HM MO e vv vvIe >NMe@NN > dd dWd WQOOOOO Woe @Mm 3e e e e a s 2@M QWwwWWW Q .emeO@@@ .e Eh9 h4M X e @ 9. @>M.T M M. MM s. e =@==eN so.

== N = ed OH O vu vvI a e V 8 a OMNT@hNu QWd dW Z .=Q000004 =@M @M

== 0e 4 4

  • i ew O@

@M a zWWWwww% Dh@oc@@ E =M

  • M

% @ @ T @ M.O.= M O > M. e MN =@M e 3 4 3 tad w 2 .* I .* Z 9 3 3 4 wz DNNT@% N >ddd dddd g S C000000 UN=e NTMe = N w oa e s

  • o og O

swwwwww e e e

moose, M

w .J@=g@~h 4OA9 Oh9M N .e.N

==aM e.eMM @ M. M. sn e +-* 4 e w

== p r O O Q C O e = a wade see m y g evv evv1 m 00000e m v =C C WO000O S a*N9@h==wNoc'o add WWW .e O wOOoooo>N-w=h NwN w > 6 e 6 s 6 e >@M N=@ .e seJ W w W w W .e v .JTeCS@@ w w T49@M@ h9 h4M MM MM e .e==.g= w =

== w+ EO ee e nA =00000 vu vv e >=....= e s .J w=Ne@h=5 WWWW dddd Adddd e z-Ne =hM. cC-me <>co=N@g= e W z o C o o, O O O hN cM= c= = =NN = 0e e e e e W eJWWWWW C E

  • Moe@e e

NQg@MM one sche hvece ahwegoc@c e e e e @MM e@MM MM@@N MMM@@@TN*

== == ==

=

=

=== = e.- O Q Z a nn e made nAMOOG 0M020<e0 O evu toevu vvvve a v v v 3 v.J e t = = z Q 3 A e= Z

  1. dddd 9009220000 2

J @e=he o c o O g @ o e v v-a== a ++e > s c= =

== s e wwwWz==== 2 e LS R MooMp p Q h*eOe Z @ o o. @ 0 mmc @N h v y v

=

aco-g W e.= w a C O

  • eOOG uvvve W

w 0 0 e e en

== to 3 e e.= W w w 3 2 020 0Ed O .Z O 2=20 2 e= 2 0 2 = 3'

== e =.J== 2 = s.= 2 e e = J w swI= g z = >en.z.aI.=e>Je.76.z. fr s 3O tw .r .a. >< r > A. g

== == q 3 v e. a O e=5 BOO .J awQ e&> 60 es e 4m 4 e e

l 33 .e g @M Q 89.J o.. o. 4, ah a se a w W s as M M

== OM Q o 9 =. . =. 9 I 2

  • hee $

d$ ONoN o.ooo s+ s e .JWWWW .J o9o9 N9MW

o. o. o. o.

MM N o*o= ed a WWIA t' >d$eW >CMMM W o. o o. o. 2 e .o. o N o N WWWW .,. N9M g C. M. o. M. MM oTo4 =* N. o vvI e a 8-4 oCN o#W = o.. o N U. 004 =dT 2 0 e + a6 oNN = d awWWW E 2 E >o@C@I >I=M I o, d. o. @. >o. 1

  • M a, -

c. = OMoM. = 3 g W q-w 4

  • . I Q

3 A u 2 >oNON >dWW# 1 3 00000 UNNN= w o+n e o* e l swwww a s ogge s O W JomTM .d o. c. o. o. a e@MM M m.i e e. I o mo=o= m, t

== c o o o l' >EMO = p a p q AWUZ 4 W Oeo v a o W o. o. C3 .J 3 c1 EchoN=9N E$$$ j H o w o. o. o. o. m N = wo@N, >M. 3 W v .J o o o o .J i, -

  • wM
o. n. o. m.

W MM 3 a e Zo de .= o. o. UWI o.. a a r' W WoNoNo WWWdW 2 ~ e,. M 5.o.o.o.o. o e-e W .W o C h. o m.

o...
e. o ~,

o. . e. M. o I i 1 AMUU o. 4 g l 2 o a 2 o o g o. o. 2 = 0 0.. e 2., d 2 oo> M o 4 I

c. o. o s

v 4 ve o o _s W 4 m o o W L.3 e i W i. I e, o .i W h. 2 ..s .Z. @T.2 e.I. Z2 I v >= c e o ea d &6 b . &o e

[N, 3 k_/ TABLE VII-E-1

  • *
  • FISH CON 5umPTION POPULATION DOSES * *
  • MAN-R[M SPon t F 3 5U *ARVEST

DOSE (MAN-REM)----------------------------

PATHWAY AGE GROUP USAGE 8ONE liver TOTAL BOOV THva0ID NIONEY LUNG GI-LLI FISH ADULT 5.8tE+04 3.8tE-02 6.00E-02 4.42E-02 9.2tE-04 2.04E-02 6.83E-0? 2.55E-03 FISH TEENAGER 9.29E+03 8.10E-03 1.28E-02 5.16f-01 1.66E-04 3.26E-03 1.65E-03 3.59E-04 FISH CHI L D 5.6tE*03 8.390-02 1.58E-02 2 H u - 01 2.380-04 8.9FE-03 9.83E-03 1.98E-04 FISH TOTAL F.30E+04 6.02E-02 8.96E-02 5.220-02 3.32E-03 2.5FE-02 1.03E-02 3 ftE-03 DILUTION CATCH TIME (HR)-INCLUDES FOOD PROCESSING Time OF 1.68E+02 HR POPULATIONat.28E+04 F.30E*00 F.30E+04 9.69E*02 AVERAGE INDIVIDUAL CONSUMPTION (MG/vR) ADULla6.90E+00 TEI Ns 5. 20E + 00 CHILD =2.20E+00

  • - I SOTOPE CONTRIBUTION
  • AGE GROUP BONE LIVER TOTAL DODV iHvROID MIDNEY LONG GI-LLI ADULT sn ?O 2%

C5 137 60% C5 137 54% I 13t 98% C5 137 61% C5 137 60% C5 83F 2F% C5 837 70% C5 134 39% C5 134 44% H 3 8% C5 134 38% C5 134 38% C5 134 161 C5 334 26% H 3 8% - CO 58 3% MN 54 2% CO 60 1% H 3 3% NO 95 43% TEENAGER SR 90 2% C5 93F 60% SR 90 1% 1 131 93% C5 137 68% C5 337 68% SR 90 1% C5 13F 70% C5 134 39% C5 33F 52% H 3 6% C5 934 38% C5 134 37% C5 837 28% C5 334 26% C5 834 46% C5 134 16% CO 58 3% WM 54 2% CO 60 q% H 3 2% NS 95 49% CHILO SR 9G t% C5 137 62% SR 90 2% I 339 94% C5 137 69% C5 33F 62% SR. 90 ft C5 13F F2% C5 134 37% C5 13F 58% H 3 5% C5 134 38% C5 134 36% C5 13F 30% C5 134 25% C5 934 45% C5 134 ISE CO 58 3% amt 54 3% -l CO 60 1% H 3 6% NS 95 37% VII-54 1

n TABLE W E-2 .v

  • *
  • rISH con 5umpTION eO*UtATION oOSES * * * '-

-j MAN-REM COMMERCIAL HARVEST


DO5E (MAM-REM)----------------------------

PATHwAV AGE GROUP USA GE SONE LIVER TOTAL SOoV THvROID MIONEY LUNG GI-LLI j FISH ADULT 3.35E+06 3.64E-03 5.82E-03 4.22E-03 6.97E-05 8.95E-03 6.52E-04 2.37E-04 FISH TEENAGER 5.35E*05 7.73E-04 1.22E-03 4.92E-04 1.25E-05 3.12E-04 1.58E-04 3.34E-05 FISH CHILD 3.23E+05 1.33E-03 8.58C-03 2.68E-04 1.78E-05 1.88E-04 1.74E-04 3.84E-05 FISH TOTAL 4.20E*06 5.74E-03 8.55E-03 4.98E-03 c.00E-04 2.45E-03 9.84E 04 2.89E-04 DILUTION CATCH T I mE ( HR )-I NCLUDES F OOD PNOC E SSI NG T I ME Of 2.40E+02 HR POPULATIONS 7.35E+05 7.30E+00 7.30E+04 2.4tE+02 AVERAGE INDIVIDUAL CONSUMPTION (MG/WR) A Da sLT = 6. 90 E + 00 TEfNe5.20E+00 CHILO=2.20E+00

  • ISOTOPE CONTRIBUTION
  • AGE GROUP BONE LIVER TOTAL 800V THVHOID KIDNEY LUNG GI-ELI ADULT SR 90 2%

C5 137 60% C5 837 54% I 13e 8E1 C5 437 68% C5 137 60% C5 337 28% C5 137 70% C5 134 39% C5 134 44% H 3 sts C5 834 38% C5 134 38% C5 134 17% C5 834 26% H 3 't% CO 58 3% MN 54 2% CO 60 2% H 3 3% NB 95 421 1 TEENAGER $R 90 2% C5 137 60% SR 90 t% I 139 92% C5 137 61% C5 137 62% SR 90 1% C5 937 70% C5 134 39% C5 137 52% to 3 7% C5 134 38% C5 134 37%- C5 137 29% C5 834 25% C5 834 45% C5 134 16% CO 58 31 MN 54 2% 4 CO 60 1% H 3 2% NS 95 40% CHILD SR 90 8% C5 337 62% SR 90 2% I 139 93% C5 837 61% C5 137 62% SR 90 8% C5 137 72% C5 134 37% C5 837 52% H 3 6% C5 834 38% C5 134 36% C5 337 30% C5 134 25% C5 134 45% C5 434 161 CO 58 3% MN 54 31 CO 60 su H 3 6% No 95 35% NEPA 005E5 NOTE--TOATL NEPA DOSE musf INCLUDE SPORT CATCH. DOSES BELOw ARE FOR COMMERCI AL CATCH ONI V


DOSE (MAN-REE)-~~---------~~~~------------

PATHwAV AGE GROUP USAGE BONE LIVER TOTAL 800f THveOID MIDNEV LUNG GI-LLI f!5H ADULT 5.8tE+04 3.8tE-02 6.09E-02 4.42E-02 7.30E-04 2.045-02 6.83E-03 2.48E-03 855H TEENAGER 9.29E+03 8.09E-03 .t.28E-02 5.tSE-03 8.3tE-04 3.265.-03 t.65E-03 3.50E-04 FISH CHILD 5.6tE+03 1.39E-02 1.58E-02 2.81E-03 3.86E-04 t.97E-03 1.82E-03 1.93E-04 FISH TOTAL 7.30E+04 6.0tE-02 8.95E-02 5.2tE-02 1.05L-03 2.56E-C2 1.03E-02 3.03E-03 VII-55 ,_.,_ _ ~

r .at a.t A at a - N ~.$..s.t l

= m.

a c _l O O N O eOMo oecMo M a 44 N v 4. OO 3 3OO < .a. vuZA AvutJ Z O s NmNN 4 e

== 0 0 O o s d 4 ae e e i 2 at at at at at $ ne at ,8 at $ at t .AWwww O -*TN m N 7 =r MNoc eNNG@ Z J Ca h - t) e ee N. M. 4 e. a c 3 e e cg*N

  • *t M 4 h9m@

%vM0 6 4 mM N mM N m.=1 N 6 a = * * *

= = ==

  • = * =

sa t NmNN 2 6 00000 N MM C 0A O eH Q t 2 i t i 5 3 U U ! =) UUIA vuIA 4 0awww it 8 404T% 0 W s eD. N @ m b O a e t @k=@. J 3 n e an A at at 38 $ $ at i I N 2 4M@ QM@ @ *J O 1 .O C to e a te m N re 4 Q t >000O en e a 2wwww J =w E I w6. e e A TM N9M e-T M I mM mM o g, % = v -= mm .O ef. === q 2 i = = - e W i m' O E

  • P*.

O A# Ae h w D Y4I VbI UVI v J ^ 2 V 5 w ONNN-2 N 2 oi.00 2

== 0 0

== 0 0 i a w e

== se at ye se A et O 2 aww6w w 0 00 ?O

  • t 0

== at > mmOE 3 0 m. er 4 (4 @M 3 IcT(o I 4 2y .I=

  • m m

e m se qe e to O w O M + m 2" 2 Q ONmNN w w ".1 m e A s e y O 30000 4 w s w i =i i t O . =.,, I =,. g 8 t .a w w w N r] g 4 ,s.= % <=t M [ 9 g a e J. . O. g. w i a g 7 i m ij e O@QN@ wie 2 0 ,e se ye se gt se,e g A,e ye w y,, w 3 e

== N O

== @ co 9 Ncm-N v m r. i 0 g, t N = m 2 e re m N e-O O e JOOO

  • w w

4

== a a i i. ** O q 3 ** *t M ON T* O% 4m H >= a w eJ w w w e h

== @ "1 m @mM 3 f'1 M W I ) 23 0 m O "=

  • = *

=" 4 =,= o. O # 0 O .J e m 3 e a u aA+ 2VA 2AA 1 i @ Jn N== e-AvVI AWVI AUV* O a .J e a e 3 NmNN O a OOOC 4 3 e e we s i s .o at * $ at ut ge i 2wwww = e w@w -vm NTN =4== = c O en

== b N *= J N *= 4 I J e s 2 0. =. @. T. 4 i y e fi c a # e a h TM N4m A Tm o e O. 3 o MM M e.m m *l )

=e

e a= @hh2 m N m.: OOOO a .J 2 00 eV A0 0e e e e 2 w 0 VVI .4 v I uVI asawww 0

== A $ f=) @ G

  • e Z >=

3 N @ P= h

  • O O

e - O== c W =aN* w 2 st se at at de se $ se se se se et

== a 2 0 - 0 "> m -Amt -Nm-W Y = 3 2 a a O p 2 y er O = w &O% 9 3 *S m. e O O @ ? m.= m a S *1 m C 7 f.==1f.=' a g v w = O w 4 4 0 0 4 O amee aaAe 22Ae w== 4 0.J e =6 eMVW eAvv 0eW4 0J2se w 3 0 < 3 w== *= 05 O e awIO N e>v> ee e n e 2 .t. 0 a dddd

== a >2222 > w O w e======== 4 d e z 0 BEE *E .J 4 0 > et O I2222 3 3 J 2 4 > = = = = = = = = c. w w 3 w /m\\ 423SG Q d Q w I ( )

  • ooOO a < e

~ v

v/

f ,/--# I ) (, ) \\/ s / \\ %) N IfWlE Vll-i.-4 -. __.__._..... - -. g o.n o (usta ut u f P A f eiar 8

  • 4GL 4,h b J B' i t ', At.1 fil)tif

&IVLH 10 fat f 4 5U V ietvH'88D +6 l l >N f V tU4G Gi-t t I DH i tan 3 #.G ACULT 2. 3.' t e a f 4.900-03 8.000 02 9. 0 7 E - 8,

1. ',9 f - 0 2 4. t* 8 F O'.s

's. E:L 03 H.531-03 DR I H u l tJ', it[NAGfR 3.17t*06 9. '8d I - 0 4 1.47f 43 1.31L-01 2.326-03 I.32E-01 1.17f-03 0.02f-01 DRINulf6 ( Hit D 4.54t*06 2.93L-03 4.101 01

3. 2* t 63
7. ?M -0)

I,H4L-03 2. 9 ta t - 0 3 2.00E-03 DR I Nm i % TOTAL 2.8tet

  • 0 7 H. 812 0 - 0 3 9.62f-02 5.5Jf-02 2.55t-02 f.21t-02 1.35L-02 1.22t-02 PO5'UL A T I Oce = R. 7 0L
  • 04 D I L u l l Ot4 5 3.13L
  • 0 5 IHAN511 11 ME = 3. l Of_
  • 01 Hk (INCluult4G 24 69H 7 068 TRLAIMirav FACILITY)

AVIRAGE I P*DI V I DU A L CONSUMP13ON (L/vn) ADutiz3.70t*02 TifNs2.bOf*02 CHI LO z 2. fiOE + 0 2 15910P0 C Ot4T R I BUT ION A ',I Grave BOht t avrie TOTAL DOD# IttVHOID A I Di4E V LUNG GI'LLI SR 89 1% C5 137 14% SR 90 7% I 13e 49% 65 817 6% CS f37 1% CO 58 1% A 30.. f 54 90 05% CS 134 9% C5 117 9% H 3 504 05 1 34 3% C5 134 1% CO 60 1% H 3 .9% H 3 84% n a 93% CS 137 2Js et 3 71% L *, 134 es 50 125 12% $8 825 1% H 3 74% C5 534 9% T E f t. AGr q SR 89 1% LS 837 2's SR 90 12% I 138 59% C5 137 0% CS 132 3% SR 90 1% 5H 90 6Ss C5 f.- 64% C5 137 H% H 3 40% C5 934 3% C5 134 2% CO 58 2% C5 137 23% H 3 61% C5 134 7% H 3 89% H 3 79% CO 0G t% C5 13e 8% is 3 71% 58 125 14% H 3 99% 50 125 5% CHILD SR 69 is CS 1?7 22% LR 90 12% I 111 64A CS L37 0% C5 137 3% et 3 95% SH 94 52% C5 ?34 14% C5 117 4s n 3 35% C$ 134 31 CS 134 2% C5 137 33% H 1 6/s C5 114 3% H 3 89% 6e 3 eb% C5 134 81% 14 3 70s 5B 125 6%


UMat A T I VE TUTAL-- --

6' A T Hw& v AGL GROUP USAGE duet t.3 vin TOTAt #100v THvRO!D et ! Df 4E Y LUNG GI-LLI DHIhmlhG COMUL TOTAL 2.05t*08 (,. 3 Ji - 02 3.tLE-01 8.

  • v t. - 01
1. tt J L - 0 3 8.Cet-02 9.73L-02 0.780-02 HV D8eO SPl at p t fulTIow t>O*g PATH.Av AGf Gn r;up (15 A GE l'f:Fif L I V T 84 TOTAt PODW THNpo[O p ! Lt;F v

( 4 tNG G[.LLg W A l f 64 TOTAL 2.2Cf*GO 2.111-09

2. tit 09 2.11 t - 09 2.11E-09 2 tit-09 2.11f-09 2.11E N VII-57

,i .s. \\ 1 l s_ I j TABLE VII-E-5 1 RECREATION POcutATION DOsts l DOSE (MAN-REM) i i PATHwAV AGE GROUP USAGE SMIN TOTAL 800V THVROID SHORELINE TOTAL POPUL

4. TOE +0F 6.55E-02 5.6tE-02.

5.6tE-02 ) LOCATION-DOWN STREAM OILUTION=0.73E+04 TRANSIT TIME =0.67E*00 HR SwfsO.2 1

  • ISOTOPE CO8TRIBUTTON
  • AGE GROUP

$NIN TOTAL 800V A DUL T C5 13F 56% C5 537 56% C5 834 tes C5 134 18% LG ks 1% CO 58 1% CO 60 17% CO 60 17% 58 125 4% 58 125 4% _ 005t(MAN-RfM) PATHWAY AGE GNOUP USAGE SMIN TOfAL BOOV THVROID SWIwwING TOTAL POPtFL

4. tot +07 0.00t*00 6.72E-04 6.721-04 LOCATION-DOWN STREAM O I LU T I ope s O. 73E + 0 8 TRANSIT TIMEsO.6TE+00 HR
  • ISOIOPE CONTRIBUTION
  • AGE GROUP

$NtN TOTAL BOOV ADULY I 938 4% C5 13F tis C5 534 25% CO 58 25% MN 54 1% CO 60 12% LA 940 61 58 325 4% AG llOM 8% DOSL(MAN-REM) PATHwAV AGE GROUP USAGE SMIN TOTAL DOOV THveOID 804 TING TOTAL POPUL

4. tot +07 0.OOE*00 3.36E-04 3.36E-04 LOCATION-DOwN STREA"

-VII-58 OILUTIONsO.73E+08 TRANSIT TIME =0.6FE+00 HR

TABLE -E-6

  • DOSE 10 sIOTA
  • e NRA05 PER.5VR ILuTION.

1.00E+00 TRANSIT T i mf = 0.00E+00 HR INTERNAL EXTERNAL TOTAL FISH 3.44E-Ot 4.39E-01 7.83E-01 INVERTE8AATE 1.90E-OS 8.76E-Ot 1.07E+00 ALGAE 2.70E-01 1.05E-03 2.7tE-01 musmRAT 3.37E+00 2.92E-Ot 3.66E+00 RACCOON 1.48E-Ol 2.19E-OS 3.66E-Ot HERON 1.14E+09 2.92E-Of 1.lFE+08 DUCu 3.84E+00 4.3eE-Of 3.58E+00

  • ISOTOPE CONTRISuTION
  • PATHNAV 800V FI5H C5 137 62%

C5 134 29% H 3 2% Me 95 3% INVERTE8 RATE C5 I37 5% C5 134 2% CO 58 3% MN $4 67% CO 60 1% H 3 4% LA 140 93% ALGAE 5R 90 2% C5 137 19% C5 134 9% CO 58 2% MN 54 5% CO 60 I% H 3 3% LA 140 46% 58 125 8% muinRAT SR 90 43% C5 137 34% C5 134 20% RACCOON SR 90 33% C5 137.29% C5 134 19% .DN 54 14% H 3 11 HERON SR 90 t% C5 537 59% C5 134 38% OuCu SR 90 46% VII-59' C5 137 33% C5 134 88%

Omaha Public Power District 1623 Harnet) Omaha. Nebraska 68102 2247 402'536-4000 February 29, 1988 LIC-88-143 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Reference:

Docket No. 50-285

SUBJECT:

Annual and Semi-Annual Reports Gentlemen: In accordance with 10CFR Section 50.36 and the Fort Calhoun Station Unit No. 1 Technical Specifications, please find attached one (1) copy of a report of the Occupational Personnel Radiation Exposures for January 1, 1987 through December 31, 1987 as prescribed in Technical Specification 5.9.1.b, and the Semi-Annual Effluent Report for Technical Specification Section 5.9.4.a for the period of July 1, 1987 through December 31, 1987. In addition, this report provides the results of quarterly dose calculations performed in accordance with Technical Specification Sections 2.9.l(l)b and 2.9.l(2)b. Results are presented by quarter for the period October 1, 1985 through December 31, 1987. Also presented are the descriptions of changes made during the preceding six months to the ODCM and/or the Process Control Program. The work contained in this report has been updated to comply with the concerns addressed in Mr. J. B. Nicnolas' Inspection Report No. 50-285/87-34. If you have any questions concerning this report, please call. Sincerely, k &%W R. L. Andrews Division Manager Nuclear Production RLA/sa g cc: LeBoeuf, Lamb, Leiby & MacRhe ( 1333 New Hampshire Ave., N.W. Washington, DC 20036 J, D. Calvo, NRC Project Director A. Bournia, NRC Project Manager P. H. Harrell, NRC Senior Resident inspector t w.un, rgngomoun w n ue, - _ _.}}