1 L

w

-QUARTERLY CUMULATIVE DOSE CONTRIBUT10NS FROM RADIDACTIVE EFFLUENTS:

3 >.

FIRST-QUARTER,-19901 1.

LIOUID EFFLUENTS:

TOTAL BODY DOSE CRI'TICAL ORGAN DOSE (MREM)

(MREM)

Monitor / Hotel Tank:-

5.43E-01 7.88E-01

- ] Rev.1:

=)

Steam Cenerator:

9.83E-05 0.00E l:

Totals:

5.43E-01 7.88E-01.

l'Rev.-If I

1 T.S.1.9.l' A. Annual Objectivo:

3.00E+00' l.00E+01-Percent of TS Annual Ob.iective:

This Quarter:

18.10%

7.88%

Year:to Date:

18.10%-

1.88%

Rev.c 1 -

II. GASE0US EFFLUENTS:

TOTAL BODY GAMMA TOTAL BODY BETA-

.c DOSE (MREM)

DOSE (MREM)

L..

?

A. -Noble Gas Air Dose:

1.48E-02 4.28E-02 T;S. 2.9.1.B.- Annual Objective:

1.00E+01

-2.00E+01 Percent of TS Annual Ob.iective:-

-This Quarter:

0.15%

0.21%

-Year to-Date:

0.15%

0.21%

B.

1-131, H 3,- and ParticUlatec TOTAL' BODY DOSE CRITICAL ORGAN DOSE' with-Hal f-Live.s- > 8 Days (MREM)

(Thyroid MREM)

- *Inhal ation:

5.09E-05 4.35E-04

  • Ground and food:

-3.77E 8.18E-02 Totals:

4.28E-04 8.22E-02 T.S.' 2.=9.1.B. Annual-Objectivo:

1.50E+01 1.50E+01 f

Percent of TS Annual Ob.iective:

This Quarter:

0.00%

0.55%

Year to Date:

0.00%

0.55%

  • Highest of Infant or Child Dose Factors Note: These revisions are submit (;d in response to Inspection Report 50-285/90-41, December 12, 1990.

9103250347 910315 I-3 Rev. 1, 3-07-91 PDR ADOCK 05000285 n

PDR

.+...:

o

+

?

QUARTERLY CUMULATIVE DOSE CONTRIBUTIONS FROM RADIDACTIVE EFFLUENTS SECOND QUARTER,- 1990

'I.

L10VID EFFLUENTS:

TOTAL BODY DOSE CRITICAL ORGAN DOSE (MREM)

(MREM)-

Monitor / Hotel Tank:

5.03E-01 7.29E 01

]> Rev. 1 Steam Generator:

1.33E-04 0.00E r Totals:

5.03E-01 7.29E-Ol_

]^Rev._1 T.S. 2.9.1' A. Annual Objective:

3.0CE+00 1.00E+01 Percent of TS Annual Ob.iactive:

This-Quarter::

16,77%

7.29%

- ) Rev. 1 -.

'i Year to Date:

34.87%

15.17%

1 l

II. GASE0VS EFFLUENTS:

TOTAL-BODY GAMMA TOTAL BODY BETA DOSE 1mREMi-DOSE-(MREM)

A.

Noble Gas Air Dose:

4.95E-04 1.15E-03 l

T.S. 2.9.1.B. Annual Objective:

1.00E+01 2.00E+01 Percent of-TS Annual Ob.iective:

This Quarter: -

0.00%

0.01%

Year.to Date:

0.15%

0.22%

B.

1-131 H 3, and Particulates TOTAL BODY DOSE CRITICAL ~0RGAN DOSE

-with Half-Lives > 8 Days (MREM 1 (Thyroid. MREM)

' *I_nhal ation:

1.99E-05 7.92E-05

  • Ground and Food:

1.31E-04 1.27E-02' Totals: '

l.51E-04 1.28E-02.

T.S.-2.9.1.B. Annual Objective:

1.50E+01-1.' 50E+01 I

Percent of TS-Annual Ob.iective:

This Quarter:

0.00%

0.09%

Year to'Date:-

0.00%

0,63%

  • Hignest of Infant or t;hild Dose Factors Note: These revisions are submitted in response to Inspection Report 50-285/90-41, December 12, 1990.