MONTHYEARML20196D0241999-06-16016 June 1999 Proposed Tech Specs Re Reactivity Control Incorporating Operating Requirements That Are Consistent with NEDO-21231, Banked Position Withdrawal Sequence ML20206R8161999-05-11011 May 1999 Proposed Tech Specs Re HPCI & RCIC Surveillance Testing ML20206H9771999-05-0505 May 1999 Proposed Tech Specs Modifying Licensing Basis for EDG on- Site Diesel Fuel Storage Requirements & Corresponding TSs ML20207F1171999-03-0303 March 1999 Proposed Tech Specs Page 3/4.6-13 Re Reactor Vessel Matl Surveillance Program Withdrawal Schedule ML20237E0851998-08-24024 August 1998 Proposed Tech Specs Pages Supporting Proposed TS Amend Related to EDG AOT ML20236X7191998-07-31031 July 1998 Proposed Tech Specs Page 3/4.9-5 Re Suppl to EDG for Allowed Outage Time ML20249C7101998-06-26026 June 1998 Proposed Tech Specs Correcting Typos & Updating Bases ML20249B3231998-06-15015 June 1998 Revised Complete Set of TS Pages Re Relocation of Radioactive Effluent TS & Radiological Environ Monitoring Program to ODCM ML20217F9341998-03-26026 March 1998 Proposed Tech Specs Re EDG Allowed Outage Time ML20217H2791998-03-25025 March 1998 Proposed Tech Specs 3.6.A.1 & 4.6.A.1,pertaining to Primary Sys Boundary,Thermal & Pressurizations Limitations & Surveillance Requirements & Basis 3/4.6.A ML20203D4981998-02-20020 February 1998 Proposed Tech Specs Pages,Incorporating Ultimate Heat Sink Temperature of 75 F Into TS 3/4.5.B & Bases,As Required by Amend 173 ML20217K5691997-10-24024 October 1997 Proposed Tech Specs Page Adding Footnote Declaring One Containment Isolation valve,30-CK-432,operate for Limited Period Despite Not Being within IST Interval for Reverse Flow Testing ML20211G2311997-09-12012 September 1997 Proposed Tech Specs Re Radiological Environ Monitoring Program Moved to ODCM ML20210K4381997-08-0808 August 1997 Revised TS Pages 3/4.5-7,B3/4.5-6 & B3/4/.5-7 Requiring Verification That SBO-DG Is Operable Prior to Voluntarily Entering LCO ML20196J0041997-07-22022 July 1997 Proposed Revised TS Bases for Section 3.5.F,correcting Volume of Water Available in Refuel Cavity & Dryer/Separator Pool When Flooded to Elevation 114 Ft & Revising Torus Water Volume to Reflect Volume Above Min Pump NPSH ML20136J5501997-03-0707 March 1997 Proposed Tech Specs Rev for Section 3.10, Core Alterations Allowing Removal of Suspect Fuel Bundles Out of Planned Sequence ML20134C9671997-01-24024 January 1997 Proposed Tech Specs 2.0 Re Safety Limits ML20133A6511996-12-23023 December 1996 Proposed Revised Tech Specs 1.0 Re definitions,3.4 Re Standby Liquid Control sys,3.5 Re Core & Containment Cooling systems,3.7 Re Containment Systems & 3.9 Re Auxiliary Electrical Sys ML20132E5491996-12-10010 December 1996 Proposed Tech Specs Table 3.2.C.1 Re Instrumentation That Initiates Rod Blocks,Table 3.2.C.2 Re Control Rod Block Instrumentation Setpoints & Table 4.2.C Re Minimum Test & Calibr Frequency for Control Rod Blocks Actuation ML20135C1461996-11-26026 November 1996 Proposed Tech Specs,Modifying Definition 1.M, Primary Containment Integrity, to Include All Instrument Line Flow Check Valves to Make Definition Consisten W/Lco 3/4.7.A.2.a.4 ML20134K4361996-11-0707 November 1996 Proposed Tech Specs Re Installation of BWROG Enhanced Option 1A ML20117K6551996-09-0505 September 1996 Proposed Tech Specs,Providing Revised TS Pages 3/4.5-7 & 3/4.5-6 ML20116M1561996-08-12012 August 1996 Proposed Tech Specs to Plant TS Section 6.0,Administrative Controls & Sections 6.5.B.10.C & 6.14 of Util Quality Assurance Manual ML20111B4201996-05-0101 May 1996 Proposed Tech Specs,Reflecting Implementation of 10CFR50 App J,Option B ML20108C1071996-05-0101 May 1996 Proposed Tech Specs,Relocating Administrative Controls Re QA Review & Audit Requirements of Section 6 from Plant TS to Boston Edison QA Manual ML20111C2761996-05-0101 May 1996 Proposed Tech Specs 3.1.1 Re Reactor Protection Sys (Scram) instrumentation,3.2.C.1 Re Instrumentation That Initiates Rod Blocks & 3/4.4 Re Standby Liquid Control ML20108C0581996-05-0101 May 1996 Proposed Tech Specs Re Core Alteration to LCO & Surveillance Conditions Associated W/Secondary Containment ML20108A6561996-04-25025 April 1996 Proposed Tech Specs Re Part of Overall Effort to Improve Outage Performance at Plant ML20095E0771995-12-0808 December 1995 Proposed Tech Specs Bases Page B2-2,including GE11 GEXL Correlation Axial Power Profile & R-factor Ranges & Correcting Error in GE11 GEXL Correlation Mass Flux Range in GE Design ref,NEDE-31152-P, GE Fuel Bundle Designs ML20092A4421995-08-31031 August 1995 Corrected Tech Spec Page Re Reactor High Pressure Trip Setting ML20086K2661995-07-14014 July 1995 Proposed Tech Specs Re Section 2.1,Bases:Safety Limits; Section 3.3.C,scram Insertion Times & Section 4.11.C, Minimum Critical Power Ratio to Reflect Use of Advanced GE-11 Fuel Design in Cycle 11 ML20078R6221995-02-15015 February 1995 Proposed Tech Specs Substituting for Pages Contained in Proposed TS Amends Submitted Prior to 950130 Authorization ML20078N4861995-02-0909 February 1995 Proposed Tech Specs,Increasing Reactor High Water Level Isolation Trip Level Setting ML20077M6921995-01-0909 January 1995 Proposed Reformatted Tech Specs & Bases ML20078K8151994-11-22022 November 1994 Proposed TS Pages 3/4.2-20 & 3/4.2-35 Re Tables 3.2.C-1 & 4.2.C ML20078K7961994-11-22022 November 1994 Proposed Tech Specs Re Changes to MSIV Leakage Requirement ML20077A8991994-11-22022 November 1994 Proposed Tech Specs Re Suppression Chamber Water Level ML20077B1861994-11-22022 November 1994 Proposed Tech Specs 3.5.F,4.5.F.1 & 3.9.B.1 & 2 Re EDG Allowed out-of-svc Time ML20072T0521994-09-0606 September 1994 Proposed Tech Specs Modification to Append a of Operating License DPR-35 Re Maintenance of Filled Discharge Pipe ML20072S0501994-09-0606 September 1994 Proposed Tech Specs Re Instrumentation That Initiates Primary Containment Isolation & Initiates or Controls Core & Containment Systems ML20072S0081994-09-0606 September 1994 Proposed Tech Specs Re Primary Containment,Oxygen Concentration & Vacuum Relief ML20072S0861994-09-0606 September 1994 Proposed Tech Specs Re Standby Gas Treatment & Control Room High Efficiency Air Filtration Sys Requirements ML20069M3311994-06-0909 June 1994 Proposed Tech Specs,Increasing Allowed out-of-service Time from 7 Days to 14 Days for Ads,Hpci & RCIC Sys,Including Section 4.5.H, Maint of Filled Discharged Pipe ML20067B7111994-02-0909 February 1994 Proposed Tech Specs Revising Wording for Page 3 of License DPR-35,clarifying Words to Aid Operators & Removing Obsolete Mechanical Snubber Acceptance Criterion BECO-93-156, Proposed Tech Specs Requesting Changes Supporting 24 Month Fuel Cycle (Submittal 3)1993-12-10010 December 1993 Proposed Tech Specs Requesting Changes Supporting 24 Month Fuel Cycle (Submittal 3) ML20059A9361993-10-19019 October 1993 Proposed Tech Specs for Removal of Scram & Group 1 Isolation Valve Closure Functions Associated W/Msl Radiation Monitors BECO-93-132, Proposed Tech Specs Removing Low Condenser Vacuum Scram in Order to Reduce Spurious Scrams,Unnecessary Plant Transients & Turbine First Stage Pressure Setpoint1993-10-19019 October 1993 Proposed Tech Specs Removing Low Condenser Vacuum Scram in Order to Reduce Spurious Scrams,Unnecessary Plant Transients & Turbine First Stage Pressure Setpoint ML20046D0441993-08-0909 August 1993 Proposed Tech Specs,Proposing 24 Month Fuel Cycle ML20044G1331993-05-20020 May 1993 Proposed Tech Specs Reducing MSIV Low Turbine Inlet Pressure Setpoint from Greater than or Equal to 880 Lb Psig to Greater than or Equal to 810 Psig & Reducing Min Pressure in Definition of Run Mode from 880 Psig to 785 Psig BECO-93-016, Proposed TS 3.5.C,D & E Re k-infinity Factor,Spent Fuel Pool Storage Capacity & Max Loads Allowed to Travel Over Fuel Assemblies,Respectively1993-02-11011 February 1993 Proposed TS 3.5.C,D & E Re k-infinity Factor,Spent Fuel Pool Storage Capacity & Max Loads Allowed to Travel Over Fuel Assemblies,Respectively 1999-06-16
[Table view] Category:TECHNICAL SPECIFICATIONS & TEST REPORTS
MONTHYEARML20196D0241999-06-16016 June 1999 Proposed Tech Specs Re Reactivity Control Incorporating Operating Requirements That Are Consistent with NEDO-21231, Banked Position Withdrawal Sequence ML20206R8161999-05-11011 May 1999 Proposed Tech Specs Re HPCI & RCIC Surveillance Testing ML20206H9771999-05-0505 May 1999 Proposed Tech Specs Modifying Licensing Basis for EDG on- Site Diesel Fuel Storage Requirements & Corresponding TSs ML20205A1451999-03-23023 March 1999 Core Shroud Insp Plan ML20207F1171999-03-0303 March 1999 Proposed Tech Specs Page 3/4.6-13 Re Reactor Vessel Matl Surveillance Program Withdrawal Schedule ML20151S3851998-08-31031 August 1998 Long-Term Program:Semi-Annual Rept ML20237E0851998-08-24024 August 1998 Proposed Tech Specs Pages Supporting Proposed TS Amend Related to EDG AOT ML20236X7191998-07-31031 July 1998 Proposed Tech Specs Page 3/4.9-5 Re Suppl to EDG for Allowed Outage Time ML20249C7101998-06-26026 June 1998 Proposed Tech Specs Correcting Typos & Updating Bases ML20249B3231998-06-15015 June 1998 Revised Complete Set of TS Pages Re Relocation of Radioactive Effluent TS & Radiological Environ Monitoring Program to ODCM ML20217F9341998-03-26026 March 1998 Proposed Tech Specs Re EDG Allowed Outage Time ML20217H2791998-03-25025 March 1998 Proposed Tech Specs 3.6.A.1 & 4.6.A.1,pertaining to Primary Sys Boundary,Thermal & Pressurizations Limitations & Surveillance Requirements & Basis 3/4.6.A ML20203D4981998-02-20020 February 1998 Proposed Tech Specs Pages,Incorporating Ultimate Heat Sink Temperature of 75 F Into TS 3/4.5.B & Bases,As Required by Amend 173 ML20217K5691997-10-24024 October 1997 Proposed Tech Specs Page Adding Footnote Declaring One Containment Isolation valve,30-CK-432,operate for Limited Period Despite Not Being within IST Interval for Reverse Flow Testing ML20211N6871997-09-16016 September 1997 Rev 9 to Procedure 8.I.1.1, Inservice Pump & Valve Testing Program ML20211G2381997-09-15015 September 1997 Rev 8 to PNPS-ODCM, Pilgrim Nuclear Power Station Odcm ML20211G2311997-09-12012 September 1997 Proposed Tech Specs Re Radiological Environ Monitoring Program Moved to ODCM ML20216C0631997-08-29029 August 1997 Semi-Annual Long Term Program Schedule ML20210K4381997-08-0808 August 1997 Revised TS Pages 3/4.5-7,B3/4.5-6 & B3/4/.5-7 Requiring Verification That SBO-DG Is Operable Prior to Voluntarily Entering LCO ML20196J0041997-07-22022 July 1997 Proposed Revised TS Bases for Section 3.5.F,correcting Volume of Water Available in Refuel Cavity & Dryer/Separator Pool When Flooded to Elevation 114 Ft & Revising Torus Water Volume to Reflect Volume Above Min Pump NPSH ML20210K3551997-07-0101 July 1997 Rev 16 to Procedure 7.8.1, Water Quality Limits ML20136J5501997-03-0707 March 1997 Proposed Tech Specs Rev for Section 3.10, Core Alterations Allowing Removal of Suspect Fuel Bundles Out of Planned Sequence ML20134C9671997-01-24024 January 1997 Proposed Tech Specs 2.0 Re Safety Limits ML20133A6511996-12-23023 December 1996 Proposed Revised Tech Specs 1.0 Re definitions,3.4 Re Standby Liquid Control sys,3.5 Re Core & Containment Cooling systems,3.7 Re Containment Systems & 3.9 Re Auxiliary Electrical Sys ML20132E5491996-12-10010 December 1996 Proposed Tech Specs Table 3.2.C.1 Re Instrumentation That Initiates Rod Blocks,Table 3.2.C.2 Re Control Rod Block Instrumentation Setpoints & Table 4.2.C Re Minimum Test & Calibr Frequency for Control Rod Blocks Actuation ML20135C1461996-11-26026 November 1996 Proposed Tech Specs,Modifying Definition 1.M, Primary Containment Integrity, to Include All Instrument Line Flow Check Valves to Make Definition Consisten W/Lco 3/4.7.A.2.a.4 ML20134K4361996-11-0707 November 1996 Proposed Tech Specs Re Installation of BWROG Enhanced Option 1A ML20117K6551996-09-0505 September 1996 Proposed Tech Specs,Providing Revised TS Pages 3/4.5-7 & 3/4.5-6 ML20116M1561996-08-12012 August 1996 Proposed Tech Specs to Plant TS Section 6.0,Administrative Controls & Sections 6.5.B.10.C & 6.14 of Util Quality Assurance Manual ML20117K6611996-07-17017 July 1996 Rev 15 to PNPS Procedure 1.2.2 Administrative OPS Requirements ML20108C0581996-05-0101 May 1996 Proposed Tech Specs Re Core Alteration to LCO & Surveillance Conditions Associated W/Secondary Containment ML20111B4201996-05-0101 May 1996 Proposed Tech Specs,Reflecting Implementation of 10CFR50 App J,Option B ML20111C2761996-05-0101 May 1996 Proposed Tech Specs 3.1.1 Re Reactor Protection Sys (Scram) instrumentation,3.2.C.1 Re Instrumentation That Initiates Rod Blocks & 3/4.4 Re Standby Liquid Control ML20108C1071996-05-0101 May 1996 Proposed Tech Specs,Relocating Administrative Controls Re QA Review & Audit Requirements of Section 6 from Plant TS to Boston Edison QA Manual ML20108A6561996-04-25025 April 1996 Proposed Tech Specs Re Part of Overall Effort to Improve Outage Performance at Plant ML20095E0771995-12-0808 December 1995 Proposed Tech Specs Bases Page B2-2,including GE11 GEXL Correlation Axial Power Profile & R-factor Ranges & Correcting Error in GE11 GEXL Correlation Mass Flux Range in GE Design ref,NEDE-31152-P, GE Fuel Bundle Designs ML20100J2521995-11-22022 November 1995 Rev 7 to Pilgrim Nuclear Power Station Odcm ML20092B5861995-09-0101 September 1995 Rev 0 to Third Ten-Yr Interval ISI Plan for Pilgrim Nuclear Power Station ML20092C4331995-09-0101 September 1995 Startup Test Rept for Pilgrim Nuclear Power Station Cycle 11 ML20092A4421995-08-31031 August 1995 Corrected Tech Spec Page Re Reactor High Pressure Trip Setting ML20086K2661995-07-14014 July 1995 Proposed Tech Specs Re Section 2.1,Bases:Safety Limits; Section 3.3.C,scram Insertion Times & Section 4.11.C, Minimum Critical Power Ratio to Reflect Use of Advanced GE-11 Fuel Design in Cycle 11 ML20078R6221995-02-15015 February 1995 Proposed Tech Specs Substituting for Pages Contained in Proposed TS Amends Submitted Prior to 950130 Authorization ML20078N4861995-02-0909 February 1995 Proposed Tech Specs,Increasing Reactor High Water Level Isolation Trip Level Setting ML20077Q1181995-01-13013 January 1995 Owner'S Specification for Reactor Shroud Repair ML20077M6921995-01-0909 January 1995 Proposed Reformatted Tech Specs & Bases ML20077A8991994-11-22022 November 1994 Proposed Tech Specs Re Suppression Chamber Water Level ML20077B1861994-11-22022 November 1994 Proposed Tech Specs 3.5.F,4.5.F.1 & 3.9.B.1 & 2 Re EDG Allowed out-of-svc Time ML20078K7961994-11-22022 November 1994 Proposed Tech Specs Re Changes to MSIV Leakage Requirement ML20078K8151994-11-22022 November 1994 Proposed TS Pages 3/4.2-20 & 3/4.2-35 Re Tables 3.2.C-1 & 4.2.C ML20078N8421994-11-18018 November 1994 Rev 32 to Procedure 8.7.3, Secondary Containment Leak Rate Test 1999-06-16
[Table view] |
Text
. . . .
ATTACHMENT 2 4
j REVISED TECHNICAL SPECIFICATION PAGES
- P. #95 1
- 96
- 97
- 97a a
- 98
- 99 (deleted)
- 100
- 101 i #102 (deleted)
- 225 i
i i
i 4
i i
i i
1 1
i Oog62 888 G70529 P 05000293 ~
PDR ,
--,a n LlHITING CONDITIONS FOR OPERATION SURVEILLANCE RE0llIREMENTS 3.4 STANDBY LIOUID CONTROL SYSTEM 4.4 STANDBY LIOUID CONTROL SYSTEM Aeolicability: Acolicability:
Applies to the operating status Applies to the surveillance of the Standby Liquid Control requirements of the Standby System.
Liquid Control System.
Objective: Obiective:
To assure the availability of a To verify the operability of the
' system with the capability to Standby Liquid Control System.
shutdown the reactor and maintain the shutdown condition without the use of control rods.
Soecification: SDecification:
A. Normal System Availability 1
A. Normal System Availability
- 1. During periods when fuel is in the reactor and prior to The operability of the Standby startup from a cold Liquid Control System shall be verified by the performance of condition, the Standby Liquid the following tests:
Control System shall be operable, except as specified 1. At least once per month j
in 3.4.8 below. This system each pump loop shall be need not be operable when the i
reactor is in the Cold functionally tested by j
Shutdown Condition, all recirculating operable control rods are demineralized water to the fully inserted and test tank.
Specif.ication 3.3.A is met. 2. At least once during each
, operating cycle:
.; a. Check that the system
- relief valves trip full open at pressures t
less than 1800 psig, and reseat on a falling pressure t greater than 1275 psig,
- b. Manually initiate the system, except explosive valves.
Pump boron solution through the recirculation path and back to the Standby Liquid Control Solution Tank. Check l that each pump flow j rate meets or exceeds 39 GPM against a system head c' 1275 psig.
95
.. LIM 1 TING CONDITIONS FOR OPERATION SURVEILLANCE REOUIREMENTS 3.4 STANDBY LIOUID CONTROL SYSTEM 4.4 STANDBY LIOUID CONTROL SYSTEM
- c. Manually initiate one of the Standby Liquid Control System loops and pump demineralized water into the reactor vessel.
This test checks explosion of the charge associated with the tested loop, proper operation of the valves, and pump operability. The replacement charges to be installed will be selected from the same manufactured batch as the tested charge.
- d. Both systems, 4 including both explosive valves, shall be tested in the course of two operating cycles.
B. Ooeration with Inonerable B. Surveillance with Inonerable Comoonents: Components:
- 1. From and after the date 1. When a component is found that a redundant to be inoperable, its component is made or redundant component shall found to be inoperable, be demonstrated to be Specification 3.4.A.1 operable immediately and shall be considered daily thereafter until the fulfilled and continued inoperable component is r operation permitted repaired. -
provided thtt the cos,ponent is returned to an operable condttien vithin seven days.
I l
l 1
~
96 l
1
LIMITING CONDITIONS FOR OPERATION SURVEILLANCE REQUIREMENTS 3.4 STANDBY LIQUID CONTROL SYSTEM 4.4 STANOBY LIQUID CONTROL SYSTEM )
C. Sodium Pentaborate Solution C. Sodium Pentaborate Solution !
At all times when the Standby The following tests shall be Liquid Control System is performed to verify the required to be operable the availability of the Liquid following conditions shall be Control Solution:
met:
- 1. Volume: Check at least
- 1. The net volume - once per day, concentration of the Liquid Control Solution 2. Temperature: Check at in the liquid control least once per day.
tank shall be maintained as required in Figure 3. Concentration: Check at 3.4-1. least once per month.
Also check concentration
- 2. The temperature of the anytime water or boron is 11guld control solution added to the solution, or shall be maintained above the solution temperature 48'F. If the solution is at or below 48'F.
temperature falls to or below 48'F, the system 4. Enrichment: Check B' will be flow tested to enrichment level by test verify aflow path. anytime boron is added to the solution and during
- 3. The enrichment of the each refueling outage.
11guld control solution Enrichment analyses shall shall be maintained at a be received within 30 days B'* lsotope enrichment of test performance. If exceeding 54.5 atom not received within 30 percent. days, see Table 6.9.1 for reporting requirements.
D. There are two operational considerations associated with the Standby Liquid Control sodium pentaborate solution requirements. The first consideration involves sodium pentaborate concentration / volume requirements. The second consideration involves B
isotopic enrichment. The related Limiting Conditions for Operation are delineated below:
97
. 3.4 STANDBY CONDITIONS FOR OPERATION SURVEILLANCE REQUIREMENTS 3.4 STANDBY LIQUID CONTROL SYSTEM 4.4 STANDBY LIQUID CONTROL SYSTEM D.1 If specification 3.4.A, B, or C.1 or C.2 cannot be met, the reactor shall be placed in a Cold Shutdown Condition with all operable control rods fully inserted within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
D.2 If the enrichment requirements of specification 3.4.C.3 are not met, a check shall be made to ensure that sodium pentaborate solution meets the original design criteria by comparing the enrichment, concentration and volume to established criteria. If the sodium pentaborate solution does not meet the original design criteria, the reactor shall be placed in a Cold Shutdown Condition with all operable control rods fully inserted l within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
D.3 If the sodium pentaborate solution meets the original design criteria, but the enrichment requirements of specification 3.4.C.3 are not met, bring the B' isotopic enrichment to greater than 54.5 atom percent within seven days from the time of receipt of the enrichment report. If after this time period the enrichment requirements of specification 3.4.C.3 are still not met, submit a report to the NRC within seven days and advise them of plans to bring the solution up to a demonstratable 54.5 atom percent B isotopic enrichment.
97a
0)
[ [
w/
Tank Overflow 10 Line of Minimum Sodium 9.5 -- /Pentaborate Weight 9.22 g 8.82 Region of Required Volume -
\ Concentration (Entire Zone) 8.5 -- 8.42
% Sodium Pentaborate l Minimum Minimum Boron Concentration by 8 Concentration Bio Isotope Weight 7.5 .
Line Enrichment
> 54.5 Atom Percent 7
6.5 -- 2068 4696 I ;
6 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 V. Net Tank Votume (Gallons)
Figure 3.4 - 1 Sodium Pentaborate Solution Volume and Concentration Requirements Amendment No. Page 98
e 4
Page 99 (intentionally deleted) l T
4 L
I 4
1 J
I l
99
. . ~ . _ . - _ _ . - _ _ , . _ _ , _ . _ _ . . _ _ _ . _ _ _ . . _ _ . . _ . _ _ _ . . _ . _ . _ _ _ _ _ _ . _ - . . _ _ _ _ _ , _ _ _ . . . _ . . . . _ _ _ . _ _ _ . . . _
BASES:
3.4 & 4.4 STANDBY LIQUID CONTROL SYSTEM A. The requirements for SLC capability to shut down the reactor are identified via the station Nuclear Safety Operational Analysis (Appendix G to the FSAR, Special Event 45). If no more than one operable control rod is withdrawn, the basic shutdown reactivity requirement for the core is satisfied and the Standby Liquid Control system is not required. Thus, the basic reactivity requirement for the core is the primary determinant of when the standby liquid control system is required. The design objective of the standby liquid control system is to provide the capability of bringing the reactor from full power to a cold, xenon-free shutdown condition assuming that none of the withdrawn control rods can be inserted. To meet this objective, the Standby Liquid Control system is designed to inject a quantity of boron that produces a concentration equivalent to 700 ppm of natural boron in the reactor core. The 700 ppm equivalent concentration in the reactor core is required to bring the reactor from full power to a three percent 6 k subtritical condition, considering the hot to cold reactivity difference, xenon poisoning etc. The system will inject this boron solution in less than 125 minutes. The maximum time requirement for inserting the boron solution was selected to override the rate of reactivity insertion caused by cooldown of the reactor following the xenon poison peak.
The Str.ndby Liquid Control system is also required to meet 10CFR5J.62 (Requirements for Reduction of Risk from Anticipated Transients Without Scram (ATHS) Events for Light-Water-Cooled Nuclear Power Plants). The Standby Liquid Control system must have the equivalent control capacity (injection rate) of 86 gpm at 13 percent by wt. natural sodium pentaborate for a 251" diameter reactor pressure vessel in order to satisfy 10CFR50.62 requirements. This corresponds to an equivalent control capacity (injection rate) of 66 gpm at 13 percent by wt.
natural sodium pentaborate solution for the PNPS reactor pressure vessel diameter of 218". This equivalency requirement is fulfilled by a combination of concentration, B' enrichment and flow rate of sodium pentaborate solution. A minimum 8.427.
concentration and 54.57. enrichment of B'" isotope at a 39 GPM pump flow rate satisfies the ATHS Rule (10CFR 50.62) equivalency requirement.
Because the concentration / volume curve has been revised to reflect the increased B'" isotopic enrichment, an additional requirement has been added to evaluate the solution's capability to meet the original design shutdown criteria whenever the B'" enrichment requirement is not met.
Experience with pump operability indicates that the monthly test, in combination with the tests during each operating cycle, is sufficient to maintain pump performance. The only practical time to fully test the liquid control system is during a refueling outage. Various components of the system are individually tested periodically, thus making more frequent testing of the entire system unnecessary.
Amendment No. 100
BASES:
l 3.4 & 4.4 STANDBY LIOUID CONTROL SYSTEM (Cont'd) l l The minimum limitation on the relief valve setting is intended to prevent the loss of sodium pentaborate solution via the lifting of a relief valve at too low a pressure. The upper limit on the relief valve settings provides system protection from overpressure.
B. Only one of the two standby liquid control pumping loops is needed for operating the system. One inoperable pumping circuit does not immediately threaten the shutdown capability, and reactor operation can continue while the circuit is being repaired. Assurance that the remaining system will perform its intended function and that the long term average availability i
of the system is not reduced is obtained for a one out of two system by an allowable equipment out of service time of one third of the normal surveillance frequency. This method determines an equipment out of service time of ten days.
Additional conservatism is introduced by reducing the allowable out of service time to seven days, and by increased testing of the operable redundant component.
C. The quantity of B' stored in the Standby Liquid Control System Storage Tank is sufficient to bring the concentration of B'" in the reactor to the point where the reactor will be shutdown and to provide a minimum 25 percent margin beyond the amount needed to shutdown the reactor to allow for possible Imperfect mixing of the chemical solution in the reactor water.
Level indication and alarm indicate whether the solution volume has changed, which might indicate a possible solution concentration change. Test intervals for level monitoring have been established in consideration of these factors.
Temperature and liquid level alarms for the system are annunciated in the control room.
The solution shall be kept at least 10*F above the maximum saturation temperature to guard against boron precipitation.
Minimum solution temperature is 48'F. This is 10*F above the saturation temperature for the maximum allowed sodium pentaborate concentration of 9.22 Ht. Percent.
Each parameter (concentration, pump flow rate, and enrichment) is tested at an interval consistent with the potential for that parameter to vary and also to assure proper equipment performance. Enrichment testing is required when material is received and when chemical addition occurs since change cannot occur by any process other than the addition of new chemicals to the Standby Liquid Control solution tank.
l 101 l \
l L
1 1
I Pa9e 102 (Intentionally deleted) l 4
I l
l 102 i
TABLE 6.9.1 Area Reference Submittal Date
- a. Secondary Containment 4.7.C.c Upon completion of Leak Rate Testing (1) each test (2)
I
- b. (Deleted)
- c. (Deleted)
- d. Gross Gaseous Release 4.8.B. Ten days after the 0.05 Cl/sec for 48 release occurs Hours
- e. Standby Liquid Control 3.4.C.3 Fourteen days after solution enrichment out receipt of a non-of specification complying enrichment report or lack of receipt of such a report within the required thirty days, if enrichment compilance cannot be achieved within seven days.
NOTES: 1. Each integrated leak rate test of the secondary containment shall be the subject of a summary technical report. This report shall include data on the wind speed, wind direction, outside and inside temperatures during the test, concurrent reactor building pressure, and emergency ventilation flow rate. The report shall also include analyses and interpretations of those data which demonstrate compliance with the specified leak rate limits.
- 2. The report shall be submitted within 90 days after completion of each test. Test periods shall be based on the commercial service data as the starting point.
225 l