_ _ _ _

+

t,

(

A, MAY 3 B78 g $p MDORANDUM FOR: Domenic B. Vassallo, Assistant Director for Lisbt Water Reactors, DPM FROP':

William P. Can=411, Assistant Director for Site Taehaalogy DSE

SUBJECT:

FAULTING MORTE OF DIABLO CANTON REPORTED BY JANES D& TIS (CMG)

Reference is made to the memorandomi from J. Carl Stepp, to me dated May 1,1978, estjent as above (copy of which is enclosed).

Arrangements are being made for two mee6ers of our staff, Renner B.

Hofanan, Imader, Geology and Seismology Section, and Richard B.

McMullen, staff geologist, to inspect the site of the fault exposeres on May 3, 1978. I will keep you informed as new information i

is obtained on this subject.

i It is my recommandstica that Dr. Stepp's memorandum be transmitted r

to the Atoute Safety and Licensing Board on Diablo Canyon.

Origins! Signed by W

.. P. Gammill N

Wi114mm P. Gemmill, Assistant Director for Site Technology i

Division of Site Safety and

{

Environmental Analysis I

Enc h es DISTRIBUTION:

As sta W DOCKET FILE (50-275-323)

NRR RDG ec w/eas1 WPG RDG i

E. R. Denton DSE RDG J. Toertellette 6

J. C. Stepp I

{

773540273 8609250324 860301 l

PDR FOIA i

HOUGH 86-391 PDR of PtCS P a

M 11:es L_

Jg/,,2/]8 b

o.ve >

. QQ g,,g

. W w e'.._ _._-_ poseevisse ocesem se,e e e4 BSC 00RM Sie (M6) Maas eMe R -lor R-lot