PNO-II-85-115, licensee Reported That Transamerica Delaval DG 2B Experienced Two Failures of Main Bearing Number 7 During Test Runs Following tear-down Inspection.Believed That First Failure Due to Inadequately Supported Bearing

From kanterella
(Redirected from ML20212F500)
Jump to navigation Jump to search
PNO-II-85-115:licensee Reported That Transamerica Delaval DG 2B Experienced Two Failures of Main Bearing Number 7 During Test Runs Following tear-down Inspection.Believed That First Failure Due to Inadequately Supported Bearing
ML20212F500
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 12/06/1985
From: Burger C, Dance H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
PNO-II-85-115, NUDOCS 9711040307
Download: ML20212F500 (1)


(____ _ _ - - _ -

p g if)vn a A) .

l(W 3. Iklf Decembar 6, 1985 b

HEl.lMINARYNOTIFICATIONOFEVENTORUNUSUALOCCURRENCEPHO-II-85-115 s preliminasy notification constitutes EARLY notice of events of POSSIBLE safety or (31tc interest significance. The information is as initially received without verifi-cation or evaluation, and is basically all that is known by the Region 11 staff on this date.

FACILITY: Duke Power Company Licensee Emergency Classification:

Catawba Unit 2 Notification of Unusual Event Docket No. 50-414 Alert Rock Hill, South Carolina Site Area Emergency General Emergency X Not Applicable rutt10 SOCUMEC lMM

SUBJECT:

TRANSAMERICA DELAVAL DIESEL GENERATOR BEARING FAILURES Tha licensee reports that TransameriY DMd MsW enerator 9 28 has experienced two failures of main bearing No. 7 during test runs following a tear-down inspection.

TitdC PLQUL'.itC8 The failures occurred after five hours of testing on November 20 and after four minutes on December 5. The No. 7 bearing,was one of five main bearings not specifically inspected during the tear-down inspection!

Following the November failure, the bearings were inspected and found to be satisfactory.

However, minor scratches were observed, and res ring of the No. 7 cast aluminum split-ring bearing had failed at the minimum wall section of the oil inlet groove. Five of seven rings inspected were replaced.

.~.7m an V licensee's initial evaluation believes the cause of the first failure to be inadequately supported bearing. A detailed failure analysis was in progress at the time of the December 5 failure.

The licensee is conducting inspection and evaluation of circumstances associated with this event. Region II will conduct routine followup.

These failures are expected to delay the current scheduled January 15, 1986 fuel load date for Catawba Unit 2.

The licensee and the NRC are prepared to respond to media inquiries.

The State of South Caroline has been informed.

The NRC received initial notification of this event by telephone from the licensee on December 5, 1985.

This information is current as of 10:00 a.m. (EST) on December 6.

Contact:

C. Burger, 242-4198 H. Dance, 242-5533 DISTRIBbTION:

H. Street MNBB Phillips E/W Willste Mall:

)

Chairman Palladino RiU~ hTlR T NMSS XDM:0MB PA OlA RES 00T: Trans Only 0 I

m. Asselstine Applicable State 4,mm. RobertsMPA AE00 s0 .

1 9711040307 851206 PDR I&E PNO-!!-85-115 PDR i