Proposed Typed Tech Specs Pages,Revising Credit for Boron & Enrichment Increase for Fuel Storage
ML20211N245
Person / Time
Site: Vogtle  
Issue date: 10/10/1997
From:
SOUTHERN NUCLEAR OPERATING CO.
To:
Shared Package
ML20211N239 List:
References
NUDOCS 9710160065
Download: ML20211N245 (31)


Text

,

TABLE OF CONTENTS (continued)

L2 f.L&MT SYSTEMS 3.7-1 3.7.1 Main Steam Safety Valves (MSSVs)...........

3.7-1 3.7.2 Main Steam Isolation Valves (MSIVs) 3.7-5 3.7.3 Main Feedwater Isolation Valves (MFIVs) and Main Feedwater Regulation Valves (MFRVs) and Associated Bypass Valves 3.7-7 3.7.4 Atmospheric Relief Valves (ARVs)...........

3.7-9 3.7.5 Auxiliary Feedwater (AFW) System...........

3.7-11 3.7.6 Condensate Storage Tank (CST) - (Redundant CSTs)...

3.7-15 3.7.6a Condensate Storage Tank (CST) - (Non-redundant CSTs).

3.7-16 3.7.7 Component Cooling Water (CCW) System.........

3.7-17 3.7.8 Nuclear Service Cooling Water (NSCW) System 3.7-19 3.7.9 Ultimate Heat Sink (VHS)...............

3.7-21 3.7.10 Control Room Emergency Filtration System (CREFS) - both Units Operating 3.7-24 3.7.11 Control Room Emergency Filtration System (CREFS) - One Unit Operating..................

3.7-27' 3.7.12 Control Room Emergency Filtration System (CREFS) - Both Units Shutdown..................

3.7-30 3.7.13 Piping Penetration Area Filtration and Exhaust System (PPAFES) 3.7-33 3.7.14 Engineered Safety Features (ESF) Room Cooler and Safety Related Chiller System..........

3.7-35 3.7.15 Fuel Storage Pool Water Level 3.7-37 3.7.16 Secondary Specific Activity.............

3.7-38 3.7.17 Fuel Storage Pool Boron Concentration 3.7-39 3.7.18 Fuel Assembl,y Storage i. the fuel Storage Pool....

3.7.40 (continued)

Vogtle Units 1 and 2 v-Amendment No.

(Unit 1) 971016006S 971010 PDR. ADOCK 05000424 P

PDR,

TA8LE OF CONTENTS (continued)

LIST OF TABLES 1.1-1 MODES 1.1-7 3.3.1-1 Reactor Trip System Instrumentation 3.3-14 3.3.2-1 Engineered Safety Feature Actuation System Instrumentation 3.3-30 3.3.3-1 Post Accident Monitoring Instrumentation.......

3.3-42 3.3.4-1 Remote Shutdown System Instrumentation and Controls 3.3-45 3.3.6-1 Containment Ventilation Isolation Instrumentation..

3.3-53 3.3.7-1 CREFS Actuation Instrumentation 3.3-59 3.7.1-1 Maximum Allowable Power Range Neutron Flux High Trip Setpoint with Inoperable Main Steam Safety Valves

. 3.7-3 3.7.1-2 Main Steam Safety Valve lift Settings 3.7-4 3.8.4-1 Discharge Test Surveillance Requirements.......

3.8-29 3.8.6-1 Battery Cell Parameters Requirements.........

3.8-35 5.5.9-1 Minimum Number of Steam Generators to Be Inspected During inservice Inspection 5.0-18 5.5.9-2 Steam Generator Tube Inspection 5.0-19 LIST 0F FIGURfJt 2.1.1-1 Reactor Core Safety Iimits..............

2.0-2 l

3.4.16-1 Reactor Coolant Dose Equivalent I-131 Reactor Coolant Specific Activity Limit Versus Percent of Rated Thermal Power with the Reactor Coolant Specific Activity > 1 Ci/ gram Dose Equivalent I-131 3.4-44 3.7.18-1 Vogtle Unit 1 Burnup Credit Requirements for All Cell Storage.................

3.7-42 3.7.18-2 Vogtle Unit 2 Burnup Credit Requirements for All Cell Storage.................

3.7-43 4.3.1-1 Vogtle Unit 1 Burnup Credit Requirements for 3-out-of-4 Storage................

4.0-4 4.3.1-2 Vogtle Unit 2 Burnur, tredit Requirements for 3-out-of-4 Storage................

4.0-5 Vogtle Units 1 and 2 viii Amendment No.

(Unit 1)

Amendment No.

(Unit 2) 7

TABLE OF CONTENTS (continued) 4.3.1-3 Vogtle Unit 2 Burnup Credit Requirements for 3x3 Storage......'...............-. 4.0-6 4.3.1-4 Vogtle Units 1 and 2 Empty Cell Checkerboard Storage Configurations.............-..-4.0-7 4.3.1-5 Vogtle Unit 2 3x3 Checkerboard Storage Configuration.

4.0-8 4.3.1-6 Vogtle Units 1 and 2 Interface Requirements (All Cell to Checkerboard Storage)........

4.0-9 4.3.1-7 Vogtle Units 1 and 2 Interface Requirements (Checkerboard Storage Interface)........., 4.0-10 4.3.1-8 Vogtle Unit 2 Interface Requirements (3x3 Checkerboard to All Cell Storage)......

4.0-11 4.3.1-9 Vogtle Unit 2 Interface Requirements

.-(3x3 to Empty tell Checkerboard Storage).....

4.0-12 Vogtle Units 1 and 2 ix Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

_----.-a.

l Fuel Storage Pool Boron Concentration 3.7.17 3.7 PLANT SYSTEMS 3.7.17 fuel Storage Pool Boron Concentration LCO 3.7.17 The fuel storage pool baron concentration shall be a 2000 ppm.

APPLICABILITY:

When fuel assemblies are stored in the fuel storage pool.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME j

A.

Fuel storage pool


NOTE------------

boron concentration LCO 3.0.3 is not applicable.

not within limit.

A.1 Suspend movement of Immediately fuel assemblies in the fuel storage pool.

AtiQ A.2.1 Initiate action to immediately restore fuel storage pool boron concentration to 4

within limit, gEILLANCEREQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.17.1 Verify the fuel storage pool boron 7 days concentration is within limit.

J Vogtle Units 1 and 2 3.7-39 Amendment No.

(Unit 1)

Amendment 6,'o.

(Unit 2)

fuel Assembly Storage in the fuel Storage Pool 3.7.18 3.7 -PLANT SYSTEMS 3.7.18 fuel Assembly Storage in the fuel Storago Pool LCO 3.7.18 The combination of initial enrichment burnup and configuration of fuel assemblies stored in the fuel storage pool shall be within the Acceptable Burnup Domain of figures 3.7.18-1 (Unit 1),1.1.3.7.18-2 (Unit 2), or in accordance with Specification 4.3.

APPLICABILITY:

Whenever any' fuel assembly is stored in the fuel storage pool.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Requirements of the A.1


NOTE---------

LCO not met.

LCO 3.0.3 is not applicable.

Initiate action to immediately move the noncomplying fuel assembly to an acceptable storage location.

Vogtle Units 1 and 2 3.7-40 Amendment No.

(Unit 1)

Amendment No.

(Unit 2) m.-__

Fuel Assembly Storage in the fuel Storage Pool 3.7.18 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.18.1 Verify by a combination of visual Prior to inspection and administrative means that storing the the initial enrichment, burnup, and storage fuel assembly location of the fuel assembly is in in the fuel accordance with Fi 3.7.18-2 (Unit 2),gures 3.7.18-1 (Unit 1),

storage pool or location.

Specification 4.3.1.1.

I Vogtle Units 1 and 2 3.7-41 Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

fuel Assembly Storage in the Fuel Storage Pool 3.7.18 0000 i

l

/

I 35000

/

/

/

30000 j

J l

h 25000 f

/

E

/

R

/

! 20000 ACCEPTABLE

/

cn

/

l E

1 h

/

(

15000

/

e

/

/

/

/

10000

,/

l UNACCEPTABLE F-

/

/

5000 7

/

f

/

0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U 235 Enrichment (nominal w/o)

Figure 3.7.18-1 Vogtle Unit 1 Burnup Credit Requirements for All Cell Storage Vogtle Units 1 and 2 3.7-42 Amendment No.

(Unit 1)

Amendment No.

(Unit 2) m.,

Fuel Assembly Storage in the Fuel Storage Po01 3.7.18 50000 t

i e

i.

i,,

i 45000

l' llll ll l

l

' i

i,.

, e,

,,,e i,.,

,,,i i i i 1 l

! i '

i!,

1 i I

4 i& I

! I i i i i i e i I i i i i iii 4C000 l'

l

l',!

l' ii i

e 4

i i

f I

/

/

3500f' i !,

i i

! i i,

ii i !,

j -

i I

I I

i l i }

i e i i r

j h

i i '

f I

!,, /

I g

i ! e i e i i i /

g30000 l,l llll l l '==ll,l j 'l 3

e i i i i i i i i i i i e t

/

1 i i i

i I/

i e

i '

i if i i i

ACCEPTABLE i i

' I i

j 25000

/

w

/

4

/

c

/

20000

['

ll

/

i h

/

f

/

i 15000

/

i i

l i j

I i ii i i i

e i

! I s'

i I

i i i i i

!I UNACCEPTABLE E

' l ' '

10000 ii

! 6/

i i

ii ii l/

I l

I iI

,ii

't i

e i i

i i i i

. i !

ii if i i i i i

i i i i i e i i 6 5000 i

i

/

, i t

i i i i e i i i i

if 4

I i l i I 6 i i i l i i

/

i i

i j ii e i i

i i i

/

I i i i !

i ij i i i e i i i l

' '.5 0

1.5 2.0 2.5 3.0 3

4.0 4.5 5.0 Initial U-235 Enrichment (nominal w/o)

Figure 3.7.18-2 Vogtle Unit 2 Burnup Credit Requirements for All Cell Storage Vogtle Units 1 and 2 3.7-43 Amendment No.

(Unit 1)

/.mendment No.

(Unit 2)

Design Features 4.0 4.0 DESIGN FEATURES (continued) 4.3 Fuel Storage 4.3.1 Criticality 4.3.1.1 The spent fuel storage racks are designed and shall be maintained with:

a.

Fuel assemblies having a maximum U-235 enrichment of 5.0 weight percent; l

b.

K l.0 when fully flooded with unborated water w$c<hincludesanallowanceforuncertaintiesas described in Section 4.3 of the FSAR.

c, k, s 0.95 when fully flooded with water borated to 4$,0 ppm (Unit 1)or500 ppm (Unit 2),which includes an allowance for uncertainties as described in Section 4.3 of the FSAR; d.

New or partially spent fuel assemblies with a combination of burnup and initial nominal enrichment in the "acceptai>1e burnup domain" of Figures 3.7.18-1 (Unit 1) or 3.7.18-2 (Unit 2) may be allowed unrestricted storage in the Unit 1 or Unit 2 fuel storage pool, respectively, e.

New or partially spent fuel assemblies with a combination of burnup and initial nominal enrichment in the " acceptable burnup domain" of Figure 4.3.1-1 may be stored in the Unit I fuel storage pool in a 3-out-of-4 checkerboard storage configuration as shown in Figure 4.3.1-4.

New or partially spent fuel assemblies with a maximum initial enrichment of 5.0 weight percent U-235 may be stored in the Unit I fuel storage pool in a 2-out-of-4 checkerboard storage configuration as shown in Figure 4.3.1-4.

Interfaces between storage configurations in the Unit I fuel storage pool shall be in compliance with Figures 4.3.1-6 and 4.3.1-7.

"A" assemblies are new or partially spent fuel assemblies with a (continued) t Vogtle Units 1 and 2 4.0-2 Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

Design Features 4.0 4.0 DESIGN FEATURES 4.3 Fuel Storage (continued) combination of burnup and initial nominal enrichment in the " acceptable burnup domain" of Figure 3.7.18.l.

"B" assemblies are new or partially spent fuel assemblies with a combination 1

of burnu) and ititial nominal enrichment in the "acce)ta)1e burnep domain" of Figure 4.3.1-1.

"C" assem)11es are ast.emblies with initial enrichments up to a maximum of 5.0 weight percent U-235.

New or partially spent fuel assemblies with a combination of burnup and initial nominal enrichment in the " acceptable burnup domain" of Figure 4.3.1-2 may be stored in the Unit 2 fuel storage pool in a 3-out-of-4 checkciboard storage configuration as shown in Figure 4.3.1-4.

New or partially spent fuel assemblies with a maximum initial enrichment of 5.0 weight percert U-235 may be stored in the Unit 2 fuel storage pool in a 2-out-of-4 checkerboard storage configuration as shown in Figure 4.3.1-4.

New or partially spent fuel assemblies with a combination of burnup and initial nominal enrichment in the " acceptable burnup domain" of Figure 4.3.1-3 may be stored in the Unit 2 fuel storage pool as " low enrichment" fuel assemblies in the 3x3 checkerboard storage configuration as shown in Figure 4.3.1-5 New or partially spent fuel assemblies with initial nominal enrichments less than or equal to 3.20 weight percent U-235 or having a maximum reference fuel -assembly K. less than or equal to 1.410 at 68'F may be stored in the Unit 2 fuel storage pool as "high enrichment" fuel assemblies in the 3x3 checkerboard storage configuration as shown in Figure 4.3.1-5.

Interfaces between storage configurations in the Unit 2 fuel storage pool shall be in compliance with Figures 4.3.1-6, 4.3.1-7, 4.3.1-8, and 4.3.1-9.

"A" assemblies are new or partially spent fuel assemblies with a combination of burnup and (continued)

Vogtle Units 1 and 2 4.0-3 Amendment No.

(Unit 1)

Amendment No.

(Unit 2) 1

Design features 4.0 l

4.0 DESIGN FEATURES 4.3 Fuel St.orage (continued) initial nominal enric...ent in the " acceptable.

burnop domain" of Figure 3.7.18-2.

"B" assemblies are new or partially spent fuel assemblies with a combination of burnup and initial nominal enrichment in the " acceptable burnup domain" of Figure 4.3.1-2.

"C" assemblies are assemblies with initial enrichments up to a maximum of 5.0 weight percent U-235.

"L" assemblies are new or partially spent fuel assemblies with a combination of burnup and initial nominal enrichment in the " acceptable burnup domain" of Figure 4.3.1-3.

"H" assemblies are new or partially spent fuel assemblies with initial nominal enrichments less than or equal to 3.20 weight percent U-235 or having a maximum reference fuel assembly K. less than or equal to 1.410 at-68'F.

f.

A nominal 10.6 inch center to center pitch in the l

Unit I high density fuel storage racks; and g.

A nominal 10.58-inch center to center pitch in the l

north-south direction and a nominal 10.4-inch center to center ) itch in the east-west direction in the Unit 2 hig1 density fuel storage racks.

4.3.1.2 The new fuel storage racks are designed and shall be-maintained with:

a.

Fuel assemblies having a maximum U-235 enrichment of 5.05 weight percent; b.

k,,, s 0.95 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 4.3 of the FSAR; c.

k,,, s 0.98 if moderated by aqueous foam, which includes an allowance for uncertainties as described in Section 4.3 of the FSAR; and d.

A nominal 21-inch center to center distance between fuel assemblies placed in the storage racks.

Vogtle Units 1 and 2 4.0-3a Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

Design Features 4.0 4.0 DESIGN FEATURES 4.3 Fuel Storage (continued) 4.3.2 Draintag The spent fuel storage pool is designed and shall be maintained to prevent inadvertent draining of the pool below elevation 194 foot-1 1/2 inch.

4.3.3 Canacity The spent fuel storage pool is designed and shall be maintained with a storage capacity limited to no more than 288 fuel attemblies in the Unit I storage pool and no more than 2098 fuel assu.-blies in the Unit 2 storage pool.

Vogtle Units 1 and 2 4.0-3b Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

Design Features 4.0 30000 l

l 1

25000

/

/

20000 5

/

3

/

o E

/

/

5

)

o 15000 ACCEPTABLE

/

?

/,

/

e 0

/

4

/

8

/

10000

/

/

/

/

/

~~

UNACCEPTABLE [

7 l

5000

/

(

/

0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U 235 Enrichment (nominal w/o)

Figure 4.3.1-1 Vogtle Unit 1 Burnup Credit Requirements for 3-out-of-4 Storage Vogtle Units 1 and 2 4.0 4 Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

Design fea:ures 4.0 30000 II ll lll ll l

l ll l

l I

25000

/

[

/

20000

~

5

/

s

/

9 s

/

/

R

$ 15000 ACCEPTABLE

/

cn Y

/

5

/

E

/

z

/

o*

10000

[

l l

/

UNACCEPTABLE 5000

/

/

/

0 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U 235 Enrichment (nominal w/o)

Figure 4.3.1-2 Vogtle Unit 2 Burnup Credit Requirements for 3-out-of-4 Storage Vogtle Units I and 2 4,0 5 Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

Design Features 4.0 50000 i

i

'ii ii i i i

i i

i ii i

I i

/

/

45000 l;

[/

c I

L i 3 l i

/

/

40000

/

/

/

/

35000

/

~~~

7 3

3 Q 30000

/

j a

/

/

5 25000

- ACCEPTABLE

/

cn

/

_x

/

g w

i j

20000 7

~5

/

S l

15000 j

/

/

UNACCEPTABLE 10000 j

/

)!

5000

/

/

/

0 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U 235 Enrichment (nominal w/o)

F'igure 4.3.1-3 Vogtle Unit 2 Burnup Credit Requirements for 3x3 Storage Vogtle Units 1 and 2 4.0-6 Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

Design Features 4.0 l

E Z

Z Z

~

Z Z Z Z Z Z Z Z Z

Z Z

Z 3 out of 4 Checkerboard Storage Z

Z

' Z Z

Z Z

Z Z

2 out of-4 Checkerboard Storage Empty Storage Cell Fuel Assembly in Storage Cell Figure 4.3.1-4 Vogtle Units 1 and 2 Empty Cell Checkerboard Storage Configurations Vogtle Units 1 and 2 4.0-7 Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

i 1

j Design Features 4.0 s

i O

O Fv O

O l

3x3 Checkerboard Storage Low Enrichment Fuel High Enric!unent Fuel O

Assembly in Storage Cell Assembly in Storage Cell s'

l i

P l

t l

j Figure 4.3.1-5 Vogtle Unit 2 3x3 Checkerboard Storage Configuration j

Vogtle Units 1 and 2 4.0-8 Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

,n,.-_,e.,

.,__,..,..-m.,-,,.-

c,_,,,,..,,_.-..,_n.,___._,,

-- ~ -., _,. - -. -

Design features 4.0 A

A A

A A

A Note:

A A

A A

A A

as Aii ccii interface Enrichment h

A A

A A

A A

Hs 3 Out Of 4 Enrichment

-~

Empty = Empty Cell Empt)

B Empty I A

A A

B B

Bl A

A A

Empty B

Empty A

A A

1 s

Boundary Between All Cell Storage and 3-out of 4 Storage A

A A

A A

A Note:

A A

A A

A A

A m All Cell Interface Enrichment

\\

A A

A A

A A

" " 3 "' f 4 Enrichment a_

C = 2 Out Of.4 Empty B

Empty I A

A A

Enrichment Empty = Empty Cell C

Empiy B

A A

A Empty C

Empty A

A A

I e

ndary Between All Cell Storage and 2-out of 4 Storage Note:

1. A row ot' empty cells can be used at the interface to separate the configurations.
2. It is acceptable to replace an assembly with an empty cell.

Figure 4.3.1-6 Vogtle Units 1 and 2 Interface Requirements (All Cell to Checkerboard Storage)

Vogtle Units 1 and 2 4.0-9 Amendment No.

(Unit 1)

Amendment No.

(Unit 2) l

Design Features 4.0 i

B Empt)

B En st3 8

Empt)

B B

B}

B B

B n = 3.out.or :

Note:

Enriche ent N

B Empty B

Empty B

Empty C = 2.Out.ON Enrichment l

~

~-

Empty = Empty Cell Empty C

Empty B

B B

C Empty IC '

Empty B

Empty Empty C

Empty,

B B

B 1

a Boundary Between 2-out-of-4 Storage and 3-out-of 4 Storage Empty B

Empty B

B B

Note:

B B

B B

Empty B

n - 3.out.or-Enrichment Empty B

Empty B

B B

C = 2.oyt. ora Ennchment Empty = Empty Cell C

Empiy Cl Empiy B

Empty Empty C

Empty B

B B

C Empiy C

Empiy B

Empty i

I a

Boundary Between 2-out-of-4 Storage and 3-out-of-4 Storage Note:

1. A row of empty cells can be used at the interface to separate the configurations.
2. It is acceptable to replace an assembly with an empty cell.

Figure 4.3.1-7 Vogtle Units 1 and 2 Interface Requirements (Checkerboard Storage Interface)

Vogtle Units 1 and 2 4.0-10 Amendment No.

(Unit 1)

Amendment No.

(Unit 2) s

(

Design Features l

4.0 A

A A

A A

A Note:

A A

A A

A A

A - All Cell Enrichment Intedace L = Low Enrichment of h

L L

L L

A A

3x3 Checkerboard 11 = lilgh Enrichment of 313 Checkerboard L

L L i L

A A

I L

H L

L A

A L

L L

L A

A i

a Note:

1. A row of empty cells can be used at the interface to separate the configurations.
2. It is acceptable to replace an assembly with an empty cell.

Figure 4.3.1-8 Vogtle Unit 2 Interface Requirements (3x3 Checkerboard to All Cell Storage)

Vogtle Units 1 and 2 4.0-11 Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

Design Features 4.0 B

B B

B B

B*

N :

j B = 3-Out-Or-4 Empty B

Empty B

Empn g

Enrichm' l E d be Interface N

L L

L L

B B

or 3:3 storage i

H = IUgh Enrichmet; L

L Li L

tm,n B

or 3ra storage Empty = Empty Cell L

H LI L

B B

L L

Ll L

Empn 8

s Boundary Between 3x3 Storage and 3-out-of-4 Storage Note:

n=3 u r

C Empo C

tmpty C

repo Empts B

Empo B

Empty C

L = Low Enrichment or3:3 Storage Interface

" " # h ** ""

8 N

L L**

L L**

B repts of 3x3 storage C = 2 Out-Or-4 1

L L

Li L

tmpo C

Enrichment -

"" W"#

L H

L L**

B tmp:3 L

L Ll L

Empn C

a Boundary Between 3x3 Storage and 2-out-of-4 Storage Note:

1. A row of empty cells can be used at the interface to separate the configurations.
2. It is acceptable to replace an assembly with an empty cell.
3. For the 3-out-of-4 configuration, the row beyond the Low enrichment can swap empty and B assemblies, however the next outer row must change the indicated assembly (*) to an enipty cell.
4. For the 2-out-of-4 configuration, the row beyond the Low enrichment can swap empty and B assemblies, however the next outer row of empty and C assemblies must also swap locations.
5. If empty cells are in indicated locations (**), then the face adjacent B assemblies can be C assemblies.

Figure 4.3.1-9 Vogtle Unit 2 Interfacc Requirements (3x3 to Empty Cell Checkerboard Storage)

Vogtle Units 1 and 2 4.0-12 Amendment No.

(Unit 1)

Amendment No.

(Unit 2)

i TABLE OF CONTENTS I

B 3.7 PLANT SYSTEMS

.................... B 3.7-1 B 3.7.1 Main Steam Safety Valves (MSSVs)._.......... B 3.7-1 B 3.7.2 Main Steam Isolation Valves (MSIVs)

B 3.7-7 B 3.7.3 Main feedwater Isolation Valves (MFIVs) and Main feedwater Regulation Valves (MFRVs) and Associated Bypass Valves............. B 3.7-14 B 3.7.4 Atmospheric Relief Valves (ARVs)........... B 3.7-21 B 3.7.5 Auxiliary Feedwater (AFW) System........... B 3.7-26 B 3.7.6 Condensate Storage Tank (CST)

B 3.7-35 B 3.7.7 Component Cooling Water (CCW) System......... B 3.7-40 B 3.7.8 Nuclear Service Cooling Water (NSCW) System B 3.7-45 B 3.7.9 Ultimate Heat Sink (VHS)............... B 3.7-50 B 3.7.10 Control Room Emergency Filtr'ation System (CREFS) -

Both Units Operating............... B 3.7-55 B 3.7.11 Control Room Emergency Filtration System (CREFS) -

(

One Unit Operating................ B 3.7-64 B 3.7.12 Control Room Emergency Filtration System (CREFS) -

Both Units Shut Down..........,.... B 3.7-70 B 3.7.13 Piping Penetration Area Filtration and Exhaust System (PPAFES)

B 3.7-75 B 3.7.14 Engineered Safety Feature (ESF) Room Cooler and Safety-Related Chiller _ System B 3.7-80 B 3.7.15 Fuel Storage Pool Water Level B 3.7-85 3

8 3.7.16 Secondary Specific Activity B 3.7-88 B 3.7.17 Fuel Storage Pool Boron Concentration B 3.7-92 8 3.7.18 Fuel Assembly Storage in the Fuel Storage Pool.... B 3.7-97 (continued)

Vogtle Units 1 and 2 iv Revision No.

Fuel Storage Pool Boron Concentration B 3.7.17 8 3.7 PLANT SYSTEMS B 3.7.17 Fuel Storage Pool Boron Concentration BASES BACKGROUND Fuel assemblies are stored in high density racks.

The Unit I spent fuel storage racks contain storage locations for 288 fuel assemblies, and the Unit 2 spent fuel storage racks contain storage locations for 2098 fuel assemblies.

Westinghouse 17x17 fuel assemblies with initial enrichments of up to and including 5.0 weight percent U-235 can be stored in any location in the Unit 1 or Unit 2 fuel storage pool provided the fuel burnup-enrichment combinations are within the limits that are specified in Figures 3.7.18-1 (Unit 1) or 3.7.18-2 (Unit 2) of tre Technical Specifications.

Fuel assemblies t'nat do not meet the burnup-enrichment combination of Figures 3.7.18-1 or 3.7.18-2 may be stored in the storage pools of Units 1 or 2 in accordance with checkerboard storage configurations described in Figures 4.3.1-1 through 4.3.1-9.

The acceptable fuel assembly storage configurations are based on the Westinghouse Spent Fuel Rack Criticality Methodology, described in WCAP-14416-NP-A, Rev. 1, (Reference 4).

This methodology includes computer code benchmarking, spent fuel rack criticality calculations methodology, reactivity equivalencing methodology, accident methodology, and soluble boron credit methodology.

The Westinghouse Spent Fuel Rack Criticality Methodology ensures that the multiplication factor, K,,, of the fuel and spent fuel storage racks is less than or equal to 0.95 as recommended by ANSI 57.2-1983 (Reference 3) and NRC guidance (References 1, 2 and 6).

The codes, methods, and techniques contained in the methodology are used to satisfy this criterion on K,,.

The methodology of the NITAWL-II, XSDRNPM-S, and KENO-Va codes is used to establish the bias and bias uncertainty.

PH0ENIX-P, a nuclear design code used primarily for core reactor physic.s calculations is used to simulate spent fuel storage rack geometries.

(continued)

Vogtle Units 1 and 2 B 3.7-92 Revision No.

Fuel Storage Pool Boron Concentration B 3.7.17 BASES BACKGROUND Reference 4 describes how credit for fuel storage pool (continued) soluble boron is used under normal storage configuration conditions.

The storage configuration is defined using K.,,

calculations to ensure that the K will be less than 1.0 withnosolubleboronundernormal,,storageconditions including tolerances and uncertainties.

Soluble boron credit is then used to maintain K.,, less than or equal to 0.95.

The Unit 1 pool requires 450 ppm and the Unit 2 pool requires 500 ppm to maintain K.,, less than or equal to 0.95 for all allowed combinations of storage configurations, enrichments, and burnups.

The analyses assumed 19.9% of the boron atoms have atomic weight 10 (B-10).

The effects of B-10 depletion on the boron concentration for maintaining K,,, :s; 0.95 are negligible.

The treatment of reactivity equivalencing uncertainties, as well as the calculation of postulated accidents crediting soluble boron is described in WCAP-14416-NP-A, Rev. 1.

This methodology was used to evaluate the storage of fuel with initial enrichments up to and including 5.0 weight percent U-235 in the Vogtle fuel storage pools.

The resulting enrichment, and burnup limits for the Unit I and Unit 2 pools, respectively, are shown in Figures 3.7.18-1 and 3.7.18-2.

Checkerboard storage configurations are defined to allow storage of fuel that is not within the acceptable burnup domain of Figures 3.7.18-1 and 3.7.18-2.

These storage requirements are shown in Figures 4.3.1-1 through 4.3.1-9.

A boron concentration of 2000 ppm assures that no credible dilution event will _ result in a K,, of

> 0.95.

APPLICABLE Most fuel storage pool accident conditions will not result SAFETY ANALYSES in an increase in K.,,.

Examples of such accidents are the drop of a fuel assembly on top of a rack, and the drop of a fuel assembly between rack modules, or between rack modules and the pool wall.

From a criticality standpoint, a dropped assembly accident occurs when a fuel assembly in its most reactive ccndition is dropped onto the storage racks.

The rack structure from a criticality standpoint is not excessively deformed.

Previous accident analysis with unborated water showed that R

the dropped assembly which comes to rest horizontally on top of the rack has sufficient water separating it from the (continued)

Vogtle Units 1 and 2 B 3.7-93 Revision No.

Fuel Storage Pool Boron Concentration B 3.7.17 BASES APPLICABLE active fuel height of stored assemblies to preclude SAFETY ANALYSES neutronic interaction.

For the borated water condition, the (continued) interaction is even less since the water contains boron, an additional thermal neutron absorber.

However, three accidents can be postulated for each storare configuration which could increase reactivity beyond the analyzed condition. The first postulated accident would be a change in pool temperature to outside the range of temperatures assumed in the criticality analyses (50 F ';o 185'F). The second accident would be dropping a fuel assembly into an already loaded cell.

The third would be the misloading of a fuel assembly into a cell for whir.h the restrictions on location, enrichr. ant, or burnup are aot satisfied.

An increase in the temperature of the water passing through the stored fuel assemblies causes a decrease in water density which would normally result in an addition of negai.ive reactivity. However, since Boraflex is not considered to be present and the fuel storage pool water has a high concentration of boron, a density decrease causes a positive reactivity addition.

The reactivity effects of a temperature range from 32*F to 240 F were evaluated.

The increase in reactivity due to the increase in temperature is bounded by the misload accident.

For the accident of dropping a fuel assembly into ar already loaded cell, the upward axial leakage of that cell will be reduced, however, the overall effect on the rack reactivity will be insignificant.

This is because the total axial leakage in both the upward and downward directions for the entire fuel array is worth about 0.003 Ak. Thus, minimizing the upward-only leakage of just a single cell will not cause any significant increase in reactivity.

Furthermore, the neutronic coupling between the dropped assembly and the already loaded assembly will be low due to several inches of assembly nozzle structure which would separate the active fuel regions. Therefore, this accident would be bounded by the misload accident.

The fuel assembly misloading accident involves placement of a fuel assembly in a location for which it does not meet the requirements for enrichment or burnup, including the placement of an assembly in a location that is required to be left empty.

The result of the misloading is to add positive reactivity, increasing K.,, toward 0.95.

The (continued)

Vogtle Units 1 and 2 B 3.7-94 Revision No.

Fuel Storage Pool Baron Concentration B 3.7.17 BASES (continued)

APPLICABLE maximum required additional boron to compensate for this SAFETY ANALYSES event is 1250 ppm for Unit 2, and 1150 ppm for Unit 1 shich (continued) is well below the limit of 2000 ppm.

The concentration of dissolved boron in the fuel storage 3

pool satisfies Criterion 2 of the NRC Policy Statment.

LCO The fuel storage pool boron concentration is required to be 1 2000 ppm.

The specified concentration of dissolved boron in the fuel storage pool preserves the assumptions used in the analyses of the potential criticality accident scenarios as described in reference 5.

The amount of soluble boron required to offset each of the above postulated accidents was evaluated for all of the proposed storage configurations.

That evaluation established the amount of soluble boron necessary to ensure that K,, will be maintained less than or equal to 0.95 should pool temperature exceed the assumed range or a fuel assembly misload occur. The amount of soluble boron necessary to mitigate these events was determined to be 1250 ppm for Unit 2 and 1150 ppm for Unit 1.

The specified minimum boron concentration of 2000 ppm assures that the concentration will remain above these values.

In addition, the boron concentration is consistent with the boron dilution evaluation tnat demonstrated that any credible dilution event could be terminated prior to reaching the boron concentration for a K,,, of > 0.95.

These values are 450 ppm for Unit I and 500 ppm for Unit 2.

APPLICABILITY This LC0 applies whenever fuel assemblies are stored in the spent fuel storage pool.

ACTIONS A.I. A.2.1. and A.2.2 The Required Actions are modified by a Note indicating that LCO 3.0.3 does not apply.

When the concentration of boron in the fuel storage pool is less than required, immediate action must be taken to preclude the occurrence of an accident or to mitigate the consequences cf an accident in progress.

This is most (continued)

Vogtle Units 1 and 2 B 3.7-95 Revision No.

Fuel Storage Pool Boron Concentration B 3.7.17 BASES ACTIONS efficiently achieved by immediately suspending the movement (continued) of fuel assemblies. Immediate action to restore the concentration of boron is also required simultaneously with suspending movement of fuel assemblies.

This does not preclude movement of a fuel assembly to a safe position.

If the LCO is not met while moving irradiated fuel assemblies in MODE 5 or 6, LC0 3.0.3 would not be applicable.

If moving irradiated fuel assemblies while in MODE 1, 2, 3, or 4,. the fuel movement is independent of reactor operation.

Therefore, inability to suspend movement of fuel assemblies is not sufficient reason to require a reactor shutdown.

SURVEILLANCE SR 3.7.17.1 REQUIREMENTS This SR verifies that the concentration of boron in the fuel storage pool is within the required limit.

As long as this-SR is met, the analyzed accidents are fully addressed. The 7 day Frequency is appropriate because no major replenishment of pool water is expected to take

ilace over such a short period of time. The gate between tie Unit I and Unit 2 fuel storage pool is normally open.

When the gate is open the pools are considered to be connected for the purpose of conducting the surveillance.

REFERENCES 1.

USNRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants,-LWR Edition. NUREG-0800, June 1987.

2.

USNRC Spent Fuel Storage Facility Design Bases (for Comment) Proposed Revision 2, 1981.

Regulatory Guide 1.13.

3.

ANS, " Design Requirements for Light Water Reactor Spent Fuel Storage Facilities at Nuclear Power Stations," ANSI /ANS-57.2-1983.

4.

WCAP-14416 NP-A, Rev.1, " Westinghouse Spent Fuel Rack Criticality Analysis Methodology," November'1996.

5.

Vogtle FSAR, Section 4.3.2.

6.

Nuclear Regulatory Commission, Letter to All Power Reactor Licensees from B. K. Grimes, "0T Position for Review and A::ceptance of Spent Fuel Storage and Handling Applications," April 14, 1978.

Vogtle Units 1 and 2 B 3.7-96 Revision No.

-Fuel Assembly Storage in the Fuel Storage Pool B 3.7.18 B 3.7 PLANT SYSTEMS-B 3.7.18 Fuel Assembly Storage in the Fuel Storage Pool BASES BACKGROUND The Unit I spent fuel storage racks contain storage

-locations for 288 fuel assemblies, and the Unit 2 spent-fuel storage-racks contain storage locations for 2098 fuel assemblies.

-Westinghouse-17X17 fuel assemblies with an enrichment of up to and. including 5.0 weight percent U-235 can be stored in the acceptable storage configurations that are specified in Figures 3.7.18-1 (Unit 1),_3.7.18-2 (Unit 2), and 4.3.1 through 4.3.1-9.

The acceptable fuel assembly storage locations are based on the Westinghouse Spent Fuel Rack Criticality Methodology, described in WCAP-14416-NP-A, Rev. 1--(reference 1). Additional background discussion can be found in B 3.7.17.

l Westinghouse 17x17 fuel assemblies with nominal enrichments no graater than 1.79 w/o'"U may be stored in all storage cell locations of the Unit 1 pool.

Fuel assemblies with initici nominal enrichment greater than 1.79 w/o*"U must satisfy a minimum burnup requirement as shown in Figure 3.7.18-1.

Westinghouse 17x17 fuel assemblies with nominal enrichments no greater than 2.45 w/o'"U may be stored in a 3-out-of-4 checkerboard arrangement with empty cells in the Unit 1 pool.

Fuel assemblies with initial nominal enrichment greater than 2.45 w/o*"U must satisfy'a minimum burnup requirement as shown in Figure 4.3.1-1.

Westinghouse 17x17 fuel assemblies with nominal enrichments no greater that 5.0 w/o'"U may be stored in a 2-out-of-4--

checkerboard arrangement with empty cells in the-Unit 1 or Unit 2 pool. There are no minimum burnup_ requirements for this configuration.

Westinghouse 17x17 fuel assemblies with nominal' enrichments no greater than 1.77 w/o*"U may be stored in all storage cell locations of the Unit 2 pool.

Fuel assemblies with initial nominal enrichment greater than 1.77 w/o'"U must satisfy a minimum burnup requirement as shown in Figure 3.7.18-2.

(continued)

Vogtle Units 1 and 2 B 3.7-97 Revision No.

Fuel Assembly Storage in the Fuel Storage Pool l

B 3.7.18 BASES BACKGROUND Westinghouse 17xl7 fuel assemblies with nominal enrichments (continued) no greater than 2.40 w/o'"U may be stored in a 3-out-of-4 checkerboard arrangement with empty cells in the Unit 2 pool.

Fuel assemblies with initial nominal enrichment greater than 2.40 w/o'"U must satisfy a minimum burnup requirement as shown in Figure 4.3.1-2.

Westinghouse 17x17 fuel assemblies may be stored in the Unit 2 pool in a 3x3 array.

The center assembl must have an initial enrichment no greater than 3.20 w/o'y'U.

Alternatively, the center of the 3x3 array may be loaded with any assembly which meets a maximum infinite multiplication factor (K.) value of 1.410 at 68 F.

One method of achieving this value of K. is by the use of IFBAs.

The surrounding fuel assemblies must have an initial nominal l

enrichment no greater than 1.48 w/o'"U or satisfy a minimum burnup requirement for higher initial enrichments as shown in Figure 4.3.1-3.

APPLICABLE Most fuel storage pool accident conditions will not result SAFETY ANALYSIS in an increase in K.,,.

Examples of such accidents are the drop of a fuel assembly on top of a rack and the drop of a fuel assembly between rack modules or between rack modules and the pool wall. However, accidents can be postulated for each storage configuration which could increase reactivity beyond the analyzed condition. A discussion of these accidents is contained in B 3.7.17.

The configuration of fuel assemblies in the fuel storage pool satisfies Criterion 2 of the NRC Policy Statement.

LCO The restrictions on the placement of fuel assemblies within the fuel storage pool ensure the K.,, of the fuel storage pool will always remain < 0.95, assuming the pool to be flooded with borated water.

The combination of initial enrichment and burnup are specified in Figurcs 3.7.18-1 and 3.7.18-2 for all cell storage in the Unit I and Unit 2 pools, respectively. Other acceptable enrichment burnup and checkerboard combinations are described in Figures 4.3.1-1 through 4.3.1-9.

(continued)

Vogtle Units 1 and 2 B 3.7-98 Revision No.

7..

f Fuel Assembly Storage in the Fuel Storage Pool B 3.7.18 BASES (continued)

APPLICABILITY This LCO applies whenever any fuel assembly is stored in the fuel storage pool.

ACTIONS Ad Required Action A.1 is modified by a Note indicating that LC0 3.0.3 does not apply.

When the configuration of fuel assemblies stored in the fuel storage pool is not in accordance with the acceptable combination of initial enrichment, burnup, and storage configurations, the immediate action is to initiate action to make the necessary fuel assembly movement (s) to bring the configuration into compliance with Figures 3,7.18-1 (Unit 1), 3.7.18-2 (Unit 2), or Specification 4.3.1.1.

If unable to move irradiated fuel assemblies while in MODE 5 or 6, LCO 3.0.3 would not be applicable.

If unable to move irradiated fuel assemblies while in MODE 1, 2, 3, or 4, the action is independent of reactor operation.

Therefore inability to move fuel assemblies is not sufficient reason to require a reactor shutdown.

SURVEILLANCE SR

3. 7 1Bd REQUIREMENTS This SR verifies by administrative means that the initial enrichment and burnup of the fuel assembly is within the acceptable burnup domain of Figures 3.7.18-1 (Unit 1) or 3.7.18-2 (Unit 2).

For fuel assemblies in the unacceptable range of Figures 3.7.18-1 and 3.7.18-2, performance of this SR will also ensure compliance with Specification 4.3.1.1.

Fuel assembly movement will be in accordance with preapproved plans that are consistent with the specified fuel enrichment, burnup, and storage configurations. These plans are administratively verified prior to fuel movement.

Each assembly is verified by visual inspection to be in accordance with the preapproved plan prior to storage in the fuel storage pool.

Storage commences following unlatching of the fuel assembly in the fuel storage pool.

9 (continued)

Vogtle Units 1 and 2 8 3.7-99 Revision No.

Fuel Assembly Storage in the fuel Storage Pool B 3.7.18 BAS."S (continued)

REFERENCES 1.

WCAP-14416-NP-A, Revision 1, " Westinghouse Spent fuel Rack Criticality Analysis Methodology," November 1996, i

{

Vogtle Units 1 and 2 B 3.7-100 Revision No.