PNO-III-85-067A, on 850809,licensee Will Resume Low Power Testing.Region III Approved Util Corrective Action Program Submitted on 850807,in Response to 850702 Premature Criticality.Plant Still Restricted to 5% Power

From kanterella
(Redirected from ML20133Q183)
Jump to navigation Jump to search
PNO-III-85-067A:on 850809,licensee Will Resume Low Power Testing.Region III Approved Util Corrective Action Program Submitted on 850807,in Response to 850702 Premature Criticality.Plant Still Restricted to 5% Power
ML20133Q183
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 08/09/1985
From: Chrissotimos N, Norelius C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
PNO-III-85-067A, PNO-III-85-67A, NUDOCS 8508150050
Download: ML20133Q183 (1)


r 1 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-III-85-67A Date August 9, 1985 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or gY 6 public interest significance. The information is as initially received without veri-fication or evaluation, and is basically all that is known by the staff on this date.

Facility: Detroit Edison Company Licensee Emergency Classification:

Fermi 2 Nuclear Power Plant Notification of an Unusual Event Newport, MI 48166 Alert Site Area Emergency Docket No: 50-341 General Emergency XX Not Applicable

Subject:

TEMPORARY HALT TO LOW POWER TESTING (UPDATE)

The licensee informed Region III (Chicago) that it will resume its low power testing activities beginning August 9, 1985. The licensee had announced on July 30 that it did not plan to resume lower power testing "until various equipment and procedural difficulties" had been resolved. (The plant has been shut down since July 23 for examination and repair of a fc:dwaterpump.)

The licensee informed Region III on August 7 of the corrective action program it had implemented in response to recent incidents (See PNO-III-58, 58A; PNO-III-63; and PNO-III-66). Region III agreed that the corrective actions appeared to satisfy the issues involved.

The licensee, however, is still restricted to 5 per cent power under a Confinnatory Action Lett:r(CAL),issuedJuly 16, 1985, by Region III as a result of the premature criticality incident which occurred July 2, 1985 (See PNO-III-58, 58A).

Region III resident inspectors will augment their inspection program to monitor the licensee's activities and will be in the control room observing criticality.

The licensee issued a news release announcing the restart of its low power testing program.

Th2 State of Michigan will be notified.

Region III was informed of the planned startup at 2:15 p.m. (CDT), August 8,1985. This information is current as pf 9 a.m. (CDT), August 9,1985.

.f e $

CONTACT: . ssotimos C. Norelius FT 388-5716 FTS 388-5717 DISTRIBUTION:

H. St._Q f l MNBBQ'.Q. PhillipsIh6) E/W W(M Willstebt07 Chairman Palladino E00 NRR IE NMSS Comm. Roberts PA OIA RES Comm. Asselstine MPA AE00 Comm. Bernthal ELD AirRights\ MOO MAIL:

Comm. Zech SP INP0lSW 4 ADM:DMB SECY NSACla.ag D0T: Trans Only ACRS CA Applicable Resident Site.lS@

PDR Regions I jah IIla: lap, IVIA:J'1 , V M Licensee (Corporate Office)let bt$

g81 Rev. 07/06/84

~ ~g 50e,_ 050009_

3 p