Text

.

l l

.3 E4 P o A m y rno-te J. r ttson, airc<ter. "!

e PF onte1 R. M ter. Assistant Director for Pa f uien c

Protection. OSI St% JECT:

PE ofVIEV DF r,R?fl3 Ci'LF TECmlCAt. SPECIFICAT10%

As directed by your February 27. IM4 and Harnld Denton's February 28 19R4 averend6 ny staff has reviewed the GesM c ir Technical Spectfica-u tions to detensino whether they were properly derived from the analysis and evaluation included in the appiteent's r$AR and the staff's SEP.

Each Branch wrified the accectability of the Soecifications except for the followino:

1.

T.S. 3/4 7.2 Plant Systes -- Control sooet Energency Filtration Systen is being reviamed by the Att end NETS : staffs (TAC #51463).

Post licensino tests indicated ameessive leakage of the contpel room. Air flow needed to sotatefn the speciffed 1/4" differential pressure was high. 19 eddities could result in escess've conees. the location of the air intake trations of redfonctivity due to poor atsespheric diffusion.

?.

An anbionity exists between the surveillance requirseents of T.S.

l 3/4 6.8.1 : containnet Systnpis - secondary contafsewnt Integrity and T.S; 3/4 6.8.3 Centa1senest Systems - f+n:-tci Contairement Standby Res Treatment Systen. The Conta1went Systens Pranch has the leed with AEB assisting.(TAC #51956).

The sections of the Technical Specificettons reviewed by each Branch f s attached.

{0 dt h c,. msw.,

3 U4'htsk MQ,yg Daniel R. Muller. Assistant Of rector for Radfation Protection Division of Systers intecration Attachrent:

As Stated cc-Lf4tulran

'WCam111 FJConnel p.

'040320031e a40300 (~'-

cF ADOCK 0300041d

_/

h NP

.C E pco; v.c. p

-o w.aa {