SAFETY EVALUATION BY THE RESEARCH AND POWER REACTOR SAFETY BRANCH DIVISION OF REACTOR LICENSING l
IN THE MATTER OF NORTHERN STATES POWER COMPANY PATHFINDER ATOMIC POWER PLANT
/
uv j
~
DOCKET No. 50-130 cfM C0ffrAINMENT LEAK RATE SPECIFICATION FCR POWERS BELOW l MW(t)
CHANGE NO. 7 l
I i
Introduction and Evaluation i
By application dated December 13, 1965, the Northern States Power Company (NSP) requested a change in Technical Specifications to increase the presently specified containment leak rate limit. The increased limit would be the same cs that previously specified in the license for operation below 1 MW(t). We have been informed that this change was requested because measured leakage
(
was higher than specified. Until repairs can be affected plant testing will be restricted to power levels below 1 MW(t).
In Change No. 6,.the Technical Specifications were revised to permiti full power One of the revised items was (190 MWt) operation of the Pathfinder reactor. _
the permissible containment leak rate. This limit was changed from 0.21 per day for 1 MW(t) operation to 0.11% per day for. full power operation at the same test pressure. In Proposed Change No. 7, Northern States Power Company has requested an additional provision that will permit resumption of low power reactor testing at the previously specified containment leakage rate limit of 0.2% per day. This change does not involve significant hazards considerations different than previously considered since this mode of operation is the same cs previously approved.
Conclusions Based upon our review of the information submitted, we have concluded that the operation of the Pathfinder reactor in accordance with the proposed change
'does not present significant hazards considerations not described or implicit in the hazards summary report, and there is reasonable assurance that the health and safety of the public will not be endangered.
I 8506120399 B50214 PDR FOIA PAY 85-54 PDR I
m r
(
I
- Accordingly, we believe that a new sentence should be added to Section 3.6.2 as follows:
"During initial operation of the reactor at power levels up to 1 MW(t), the containment leakage rate shall not exceed 0.2% of the contained air within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> at 78 psig."
3 Origind signed br.
!!c:tr S. Boyd Roger S. Boyd, Chief Research & Power Reactor Safety Branch Division of Reactor Licensing Date: